Search Results

Search found 22725 results on 909 pages for 'case sensitivity'.

Page 64/909 | < Previous Page | 60 61 62 63 64 65 66 67 68 69 70 71  | Next Page >

  • Bridge or Factory and How

    - by Chris
    I'm trying to learn patterns and I've got a job that is screaming for a pattern, I just know it but I can't figure it out. I know the filter type is something that can be abstracted and possibly bridged. I'M NOT LOOKING FOR A CODE REWRITE JUST SUGGESTIONS. I'm not looking for someone to do my job. I would like to know how patterns could be applied to this example. using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.Data; using System.IO; using System.Xml; using System.Text.RegularExpressions; namespace CopyTool { class CopyJob { public enum FilterType { TextFilter, RegExFilter, NoFilter } public FilterType JobFilterType { get; set; } private string _jobName; public string JobName { get { return _jobName; } set { _jobName = value; } } private int currentIndex; public int CurrentIndex { get { return currentIndex; } } private DataSet ds; public int MaxJobs { get { return ds.Tables["Job"].Rows.Count; } } private string _filter; public string Filter { get { return _filter; } set { _filter = value; } } private string _fromFolder; public string FromFolder { get { return _fromFolder; } set { if (Directory.Exists(value)) { _fromFolder = value; } else { throw new DirectoryNotFoundException(String.Format("Folder not found: {0}", value)); } } } private List<string> _toFolders; public List<string> ToFolders { get { return _toFolders; } } public CopyJob() { Initialize(); } private void Initialize() { if (ds == null) { ds = new DataSet(); } ds.ReadXml(Properties.Settings.Default.ConfigLocation); LoadValues(0); } public void Execute() { ExecuteJob(FromFolder, _toFolders, Filter, JobFilterType); } public void ExecuteAll() { string OrigPath; List<string> DestPaths; string FilterText; FilterType FilterWay; foreach (DataRow rw in ds.Tables["Job"].Rows) { OrigPath = rw["FromFolder"].ToString(); FilterText = rw["FilterText"].ToString(); switch (rw["FilterType"].ToString()) { case "TextFilter": FilterWay = FilterType.TextFilter; break; case "RegExFilter": FilterWay = FilterType.RegExFilter; break; default: FilterWay = FilterType.NoFilter; break; } DestPaths = new List<string>(); foreach (DataRow crw in rw.GetChildRows("Job_ToFolder")) { DestPaths.Add(crw["FolderPath"].ToString()); } ExecuteJob(OrigPath, DestPaths, FilterText, FilterWay); } } private void ExecuteJob(string OrigPath, List<string> DestPaths, string FilterText, FilterType FilterWay) { FileInfo[] files; switch (FilterWay) { case FilterType.RegExFilter: files = GetFilesByRegEx(new Regex(FilterText), OrigPath); break; case FilterType.TextFilter: files = GetFilesByFilter(FilterText, OrigPath); break; default: files = new DirectoryInfo(OrigPath).GetFiles(); break; } foreach (string fld in DestPaths) { CopyFiles(files, fld); } } public void MoveToJob(int RecordNumber) { Save(); LoadValues(RecordNumber - 1); } public void AddToFolder(string folderPath) { if (Directory.Exists(folderPath)) { _toFolders.Add(folderPath); } else { throw new DirectoryNotFoundException(String.Format("Folder not found: {0}", folderPath)); } } public void DeleteToFolder(int index) { _toFolders.RemoveAt(index); } public void Save() { DataRow rw = ds.Tables["Job"].Rows[currentIndex]; rw["JobName"] = _jobName; rw["FromFolder"] = _fromFolder; rw["FilterText"] = _filter; switch (JobFilterType) { case FilterType.RegExFilter: rw["FilterType"] = "RegExFilter"; break; case FilterType.TextFilter: rw["FilterType"] = "TextFilter"; break; default: rw["FilterType"] = "NoFilter"; break; } DataRow[] ToFolderRows = ds.Tables["Job"].Rows[currentIndex].GetChildRows("Job_ToFolder"); for (int i = 0; i <= ToFolderRows.GetUpperBound(0); i++) { ToFolderRows[i].Delete(); } foreach (string fld in _toFolders) { DataRow ToFolderRow = ds.Tables["ToFolder"].NewRow(); ToFolderRow["JobId"] = ds.Tables["Job"].Rows[currentIndex]["JobId"]; ToFolderRow["Job_Id"] = ds.Tables["Job"].Rows[currentIndex]["Job_Id"]; ToFolderRow["FolderPath"] = fld; ds.Tables["ToFolder"].Rows.Add(ToFolderRow); } } public void Delete() { ds.Tables["Job"].Rows.RemoveAt(currentIndex); LoadValues(currentIndex++); } public void MoveNext() { Save(); currentIndex++; LoadValues(currentIndex); } public void MovePrevious() { Save(); currentIndex--; LoadValues(currentIndex); } public void MoveFirst() { Save(); LoadValues(0); } public void MoveLast() { Save(); LoadValues(ds.Tables["Job"].Rows.Count - 1); } public void CreateNew() { Save(); int MaxJobId = 0; Int32.TryParse(ds.Tables["Job"].Compute("Max(JobId)", "").ToString(), out MaxJobId); DataRow rw = ds.Tables["Job"].NewRow(); rw["JobId"] = MaxJobId + 1; ds.Tables["Job"].Rows.Add(rw); LoadValues(ds.Tables["Job"].Rows.IndexOf(rw)); } public void Commit() { Save(); ds.WriteXml(Properties.Settings.Default.ConfigLocation); } private void LoadValues(int index) { if (index > ds.Tables["Job"].Rows.Count - 1) { currentIndex = ds.Tables["Job"].Rows.Count - 1; } else if (index < 0) { currentIndex = 0; } else { currentIndex = index; } DataRow rw = ds.Tables["Job"].Rows[currentIndex]; _jobName = rw["JobName"].ToString(); _fromFolder = rw["FromFolder"].ToString(); _filter = rw["FilterText"].ToString(); switch (rw["FilterType"].ToString()) { case "TextFilter": JobFilterType = FilterType.TextFilter; break; case "RegExFilter": JobFilterType = FilterType.RegExFilter; break; default: JobFilterType = FilterType.NoFilter; break; } if (_toFolders == null) _toFolders = new List<string>(); _toFolders.Clear(); foreach (DataRow crw in rw.GetChildRows("Job_ToFolder")) { AddToFolder(crw["FolderPath"].ToString()); } } private static FileInfo[] GetFilesByRegEx(Regex rgx, string locPath) { DirectoryInfo d = new DirectoryInfo(locPath); FileInfo[] fullFileList = d.GetFiles(); List<FileInfo> filteredList = new List<FileInfo>(); foreach (FileInfo fi in fullFileList) { if (rgx.IsMatch(fi.Name)) { filteredList.Add(fi); } } return filteredList.ToArray(); } private static FileInfo[] GetFilesByFilter(string filter, string locPath) { DirectoryInfo d = new DirectoryInfo(locPath); FileInfo[] fi = d.GetFiles(filter); return fi; } private void CopyFiles(FileInfo[] files, string destPath) { foreach (FileInfo fi in files) { bool success = false; int i = 0; string copyToName = fi.Name; string copyToExt = fi.Extension; string copyToNameWithoutExt = Path.GetFileNameWithoutExtension(fi.FullName); while (!success && i < 100) { i++; try { if (File.Exists(Path.Combine(destPath, copyToName))) throw new CopyFileExistsException(); File.Copy(fi.FullName, Path.Combine(destPath, copyToName)); success = true; } catch (CopyFileExistsException ex) { copyToName = String.Format("{0} ({1}){2}", copyToNameWithoutExt, i, copyToExt); } } } } } public class CopyFileExistsException : Exception { public string Message; } }

    Read the article

  • Incorrect output on changing sequence of declarations

    - by max
    Writing C++ code to implement Sutherland-Hodgeman polygon clipping. This order of declaration of these 2 statements gives correct output, reverse does not. int numberOfVertices = 5; Point pointList[] = { {50,50}, {200,300}, {310,110}, {130,90}, {70,40} }; I am passing the polygon vertex set to clippers in order - LEFT, RIGHT, TOP, BOTTOM. The exact error which comes when the declarations are reversed is that the bottom clipper, produces an empty set of vertices so no polygon is displayed after clipping. Correct: Incorrent: Confirmed by outputting the number of vertices produced after each pass: Correct: Incorrect: What is the reason for this error? Code: #include <iostream> #include <GL/glut.h> #define MAXVERTICES 10 #define LEFT 0 #define RIGHT 1 #define TOP 2 #define BOTTOM 3 using namespace std; /* Clipping window */ struct Window { double xmin; double xmax; double ymin; double ymax; }; struct Point { double x; double y; }; /* If I interchange these two lines, the code doesn't work. */ /**************/ int numberOfVertices = 5; Point pointList[] = { {50,50}, {200,300}, {310,110}, {130,90}, {70,40} }; /**************/ const Window w = { 100, 400, 60, 200 }; /* Checks whether a point is inside or outside a window side */ int isInside(Point p, int side) { switch(side) { case LEFT: return p.x >= w.xmin; case RIGHT: return p.x <= w.xmax; case TOP: return p.y <= w.ymax; case BOTTOM: return p.y >= w.ymin; } } /* Calculates intersection of a segment and a window side */ Point intersection(Point p1, Point p2, int side) { Point temp; double slope, intercept; bool infinite; /* Find slope and intercept of segment, taking care of inf slope */ if(p2.x - p1.x != 0) { slope = (p2.y - p1.y) / (p2.x - p1.x); infinite = false; } else { infinite = true; } intercept = p1.y - p1.x * slope; /* Calculate intersections */ switch(side) { case LEFT: temp.x = w.xmin; temp.y = temp.x * slope + intercept; break; case RIGHT: temp.x = w.xmax; temp.y = temp.x * slope + intercept; break; case TOP: temp.y = w.ymax; temp.x = infinite ? p1.x : (temp.y - intercept) / slope; break; case BOTTOM: temp.y = w.ymin; temp.x = infinite ? p1.x : (temp.y - intercept) / slope; break; } return temp; } /* Clips polygon against a side, updating the point list (called once for each side) */ void clipAgainstSide(int sideToClip) { int i, j=0; Point s,p; Point outputList[MAXVERTICES]; /* Main algorithm */ s = pointList[numberOfVertices-1]; for(i=0 ; i<numberOfVertices ; i++) { p = pointList[i]; if(isInside(p, sideToClip)) { /* p inside */ if(!isInside(s, sideToClip)) { /* p inside, s outside */ outputList[j] = intersection(p, s, sideToClip); j++; } outputList[j] = p; j++; } else if(isInside(s, sideToClip)) { /* s inside, p outside */ outputList[j] = intersection(s, p, sideToClip); j++; } s = p; } /* Updating number of points and point list */ numberOfVertices = j; /* ERROR: In last call with BOTTOM argument, numberOfVertices becomes 0 */ /* all earlier 3 calls have correct output */ cout<<numberOfVertices<<endl; for(i=0 ; i<numberOfVertices ; i++) { pointList[i] = outputList[i]; } } void SutherlandHodgemanPolygonClip() { clipAgainstSide(LEFT); clipAgainstSide(RIGHT); clipAgainstSide(TOP); clipAgainstSide(BOTTOM); } void init() { glClearColor(1,1,1,0); glMatrixMode(GL_PROJECTION); gluOrtho2D(0,1000,0,500); } void display() { glClear(GL_COLOR_BUFFER_BIT); /* Displaying ORIGINAL box and polygon */ glColor3f(0,0,1); glBegin(GL_LINE_LOOP); glVertex2i(w.xmin, w.ymin); glVertex2i(w.xmin, w.ymax); glVertex2i(w.xmax, w.ymax); glVertex2i(w.xmax, w.ymin); glEnd(); glColor3f(1,0,0); glBegin(GL_LINE_LOOP); for(int i=0 ; i<numberOfVertices ; i++) { glVertex2i(pointList[i].x, pointList[i].y); } glEnd(); /* Clipping */ SutherlandHodgemanPolygonClip(); /* Displaying CLIPPED box and polygon, 500px right */ glColor3f(0,0,1); glBegin(GL_LINE_LOOP); glVertex2i(w.xmin+500, w.ymin); glVertex2i(w.xmin+500, w.ymax); glVertex2i(w.xmax+500, w.ymax); glVertex2i(w.xmax+500, w.ymin); glEnd(); glColor3f(1,0,0); glBegin(GL_LINE_LOOP); for(int i=0 ; i<numberOfVertices ; i++) { glVertex2i(pointList[i].x+500, pointList[i].y); } glEnd(); glFlush(); } int main(int argc, char** argv) { glutInit(&argc, argv); glutInitDisplayMode(GLUT_SINGLE | GLUT_RGB); glutInitWindowSize(1000,500); glutCreateWindow("Sutherland-Hodgeman polygon clipping"); init(); glutDisplayFunc(display); glutMainLoop(); return 0; }

    Read the article

  • How do I rotate only some views when working with a uinavigationcontroller as a tab of a uitabbarcon

    - by maxpower
    Here is a flow that I can not figure out how to work. ( when I state (working) it means that in that current state the rules for orientation for that view are working correctly) First View: TableView on the stack of a UINavigationController that is a tab of UITabBarController. TableView is only allowed to be portrait. (working) When you rotate the TableView to landscape a modal comes up with a custom UIView that is like a coverflow (which i'll explain the problem there in a moment). A Selection made on tableview pushes a UIScrollview on to the stack. UIScrollView is allowed all orientations. (working) When UIScrollView is in landscape mode and the user hits back they are taken to the custom UIView that is like the coverflow and only allows landscape. The problem is here. Because the UIScrollView allows full rotation it permitted the TableView to rotate as well to landscape. I have a method attached to a notification "UIDeviceOrientationDidChangeNotification" that checks to see if the custom view is the current controller and if it is and if the user has rotated back to portrait I need to pop the custom view and show the table view. The table view has to rotate back to portrait, which really is okay as long as the user doesn't see it. When I create custom animations it works pretty good except for some odd invisible black box that seems to rotate with the device right before I fade out the customview to the tableview. Further inorder to ensure that my tableview will rotate to portrait I have to allow the customview to support all orientations because the system looks to the current view (in my code) as to whether or not that app is allowed to rotate to a certain orientation. Because of this I many proposed solutions will show the customview rotating to portrait as the table view comes back to focus. My other problem is very similar. If you are viewing the tableview and rotate the modalview of the customview is presented. When you make a selection on this view it pushes the UIScrollview onto the stack, but because the Tableview only supports portrait the UIScrollview comes in in portrait while the device is in landscape mode. How can I overcome these awful blocks? This is my current attempt: When it comes to working with UITabBarController the system really only cares what the tabbarcontroller has to say about rotation. Currently whenever a view loads it reports it supported orientations. TabBarController.m - (BOOL)shouldAutorotateToInterfaceOrientation:(UIInterfaceOrientation)interfaceOrientation { switch (self.supportedOrientation) { case SupportPortraitOrientation: [[UIApplication sharedApplication] setStatusBarHidden:NO animated:YES]; return (interfaceOrientation == UIInterfaceOrientationPortrait); break; case SupportPortraitUpsideDownOrientation: [[UIApplication sharedApplication] setStatusBarHidden:NO animated:YES]; return (interfaceOrientation == UIInterfaceOrientationPortraitUpsideDown); break; case SupportPortraitAllOrientation: [[UIApplication sharedApplication] setStatusBarHidden:NO animated:YES]; return (interfaceOrientation == UIInterfaceOrientationPortrait || interfaceOrientation == UIInterfaceOrientationPortraitUpsideDown); break; case SupportLandscapeLeftOrientation: [[UIApplication sharedApplication] setStatusBarHidden:YES animated:YES]; return (interfaceOrientation == UIInterfaceOrientationLandscapeLeft); break; case SupportLandscapeRightOrienation: [[UIApplication sharedApplication] setStatusBarHidden:YES animated:YES]; return (interfaceOrientation == UIInterfaceOrientationLandscapeRight); break; case SupportLandscapeAllOrientation: [[UIApplication sharedApplication] setStatusBarHidden:YES animated:YES]; return (interfaceOrientation == UIInterfaceOrientationLandscapeLeft || interfaceOrientation == UIInterfaceOrientationLandscapeRight); break; case SupportAllOrientation: if (interfaceOrientation == UIInterfaceOrientationLandscapeLeft || interfaceOrientation == UIInterfaceOrientationLandscapeRight) { [[UIApplication sharedApplication] setStatusBarHidden:YES animated:YES]; }else { //[[UIApplication sharedApplication] setStatusBarHidden:NO animated:YES]; } return YES; break; default: return (interfaceOrientation == UIInterfaceOrientationPortrait); break; } } This block of code is part of my UINavigationController and is in a method that responds to the UIDeviceOrientationDidChangeNotification Notification. It is responsible for poping the customview and showing the tableview. There are two different versions in place that originally were for two different versions of the SDK but both are pretty close to solutions. The reason the first is not supported on 3.0 is for some reason you can't have a view showing and then showen as a modal view. Not sure if that is a bug or a feature. The second solution works pretty good except that I see an outer box rotating around the iphone. if ([[self topViewController] isKindOfClass:FlowViewController.class]) { NSString *iphoneVersion = [[UIDevice currentDevice] systemVersion]; double version = [iphoneVersion doubleValue]; if(version > 3.0){ //1st solution //if the delivered app is not built with the 3.1 SDK I don't think this will happen anyway //we need to test this [self presentModalViewController:self.flowViewController animated:NO]; //[self toInterfaceOrientation:UIDeviceOrientationPortrait animated:NO]; [self popViewControllerAnimated:NO]; [self setNavigationBarHidden:NO animated:NO]; [self dismissModalViewControllerAnimated:YES]; }else{ //2nd solution DLog(@"3.0!!"); //[self toInterfaceOrientation:UIDeviceOrientationPortrait animated:NO]; CATransition *transition = [CATransition animation]; transition.duration = 0.50; transition.timingFunction = [CAMediaTimingFunction functionWithName:kCAMediaTimingFunctionEaseInEaseOut]; transition.type = kCATransitionPush; transition.subtype = kCATransitionFade; CATransition *tabBarControllerLayer = [CATransition animation]; tabBarControllerLayer.duration = 0.50; tabBarControllerLayer.timingFunction = [CAMediaTimingFunction functionWithName:kCAMediaTimingFunctionEaseInEaseOut]; tabBarControllerLayer.type = kCATransitionPush; tabBarControllerLayer.subtype = kCATransitionFade; [self.tabBarController.view.layer addAnimation:transition forKey:kCATransition]; [self.view.layer addAnimation:transition forKey:kCATransition]; [self popViewControllerAnimated:NO]; [self setNavigationBarHidden:NO animated:NO]; } [self performSelector:@selector(resetFlow) withObject:nil afterDelay:0.75]; } I'm near convinced there is no solution except for manual rotation which messes up the keyboard rotation. Any advice would be appreciated! Thanks.

    Read the article

  • Theme confusion in SpreadsheetML.

    - by dmaruca
    I've been fighting this all day. Inside my styles.xml file I have color information given like so: <fgColor theme="0" tint="-0.249977111117893" / ECMA 376 defines a theme color reference as: Index into the <clrScheme collection, referencing a particular <sysClr or <srgbClr value expressed in the Theme part. Ok, that sounds easy. Here is an excerpt from my clrScheme xml: <a:clrScheme name="Office" <a:dk1 <a:sysClr val="windowText" lastClr="000000" / </a:dk1 <a:lt1 <a:sysClr val="window" lastClr="FFFFFF" / </a:lt1 Index zero is black, and they are wanting to darken it? I can tell you that after the tint is applied, the color should be #F2F2F2. My confusion is what does theme="0" really mean? It can't possible mean to darken #000000. Checking MSDN only confuses me even more. From http://msdn.microsoft.com/en-us/library/dd560821.aspx note that the theme color integer begins counting from left to right in the palette starting with zero. Theme color 3 is the dark 2 text/background color. Actually, if you start counting at zero the third entry is Light 2. Dark 2 is the second one. Can anyone here shed some light on this subject for me? What does theme="0" really mean? Here is the VB6 code I have been working with to apply the tint. You can paste it into your vba editor and run the test sub. Public Type tRGB R As Byte G As Byte B As Byte End Type Public Type tHSL H As Double S As Double L As Double End Type Sub TestRgbTint() Dim c As tRGB RGB_Hex2Type "ffffff", c RGB_ApplyTint c, -0.249977111117893 Debug.Print Hex(c.R) & Hex(c.G) & Hex(c.B) End Sub Public Sub RGB_Hex2Type(ByVal HexString As String, RGB As tRGB) 'Remove the alpha channel if it exists If Len(HexString) = 8 Then HexString = mID(HexString, 3) End If RGB.R = CByte("&H" & Left(HexString, 2)) RGB.G = CByte("&H" & mID(HexString, 3, 2)) RGB.B = CByte("&H" & Right(HexString, 2)) End Sub Public Sub RGB_ApplyTint(RGB As tRGB, tint As Double) Const HLSMAX = 1# Dim HSL As tHSL If tint = 0 Then Exit Sub RGB2HSL RGB, HSL If tint < 0 Then HSL.L = HSL.L * (1# + tint) Else HSL.L = HSL.L * (1# - tint) + (HLSMAX - HLSMAX * (1# - tint)) End If HSL2RGB HSL, RGB End Sub Public Sub HSL2RGB(HSL As tHSL, RGB As tRGB) HSL2RGB_ByVal HSL.H, HSL.S, HSL.L, RGB End Sub Private Sub HSL2RGB_ByVal(ByVal H As Double, ByVal S As Double, ByVal L As Double, RGB As tRGB) Dim v As Double Dim R As Double, G As Double, B As Double 'Default color to gray R = L G = L B = L If L < 0.5 Then v = L * (1# + S) Else v = L + S - L * S End If If v > 0 Then Dim m As Double, sv As Double Dim sextant As Integer Dim fract As Double, vsf As Double, mid1 As Double, mid2 As Double m = L + L - v sv = (v - m) / v H = H * 6# sextant = Int(H) fract = H - sextant vsf = v * sv * fract mid1 = m + vsf mid2 = v - vsf Select Case sextant Case 0 R = v G = mid1 B = m Case 1 R = mid2 G = v B = m Case 2 R = m G = v B = mid1 Case 3 R = m G = mid2 B = v Case 4 R = mid1 G = m B = v Case 5 R = v G = m B = mid2 End Select End If RGB.R = R * 255# RGB.G = G * 255# RGB.B = B * 255# End Sub Public Sub RGB2HSL(RGB As tRGB, HSL As tHSL) Dim R As Double, G As Double, B As Double Dim v As Double, m As Double, vm As Double Dim r2 As Double, g2 As Double, b2 As Double R = RGB.R / 255# G = RGB.G / 255# B = RGB.B / 255# 'Default to black HSL.H = 0 HSL.S = 0 HSL.L = 0 v = IIf(R > G, R, G) v = IIf(v > B, v, B) m = IIf(R < G, R, G) m = IIf(m < B, m, B) HSL.L = (m + v) / 2# If HSL.L < 0 Then Exit Sub End If vm = v - m HSL.S = vm If HSL.S > 0 Then If HSL.L <= 0.5 Then HSL.S = HSL.S / (v + m) Else HSL.S = HSL.S / (2# - v - m) End If Else Exit Sub End If r2 = (v - R) / vm g2 = (v - G) / vm b2 = (v - B) / vm If R = v Then If G = m Then HSL.H = 5# + b2 Else HSL.H = 1# - g2 End If ElseIf G = v Then If B = m Then HSL.H = 1# + r2 Else HSL.H = 3# - b2 End If Else If R = m Then HSL.H = 3# + g2 Else HSL.H = 5# - r2 End If End If HSL.H = HSL.H / 6# End Sub

    Read the article

  • Rails form submission

    - by Danny McClelland
    Hi Everyone, I have a simple form to enter details of a new case (kase), it's working well and clicking submit stores the information and takes the user to the show.html.erb page. However, I wanted to move part of the form to the sidebar - to make things a little easier to see and use for the user, however, when I moved the section to the sidebar - anything entered during either a creation or edit within those sidebar fields is ignored. Any idea how I keep the fields in the sidebar, but include them as before? <% content_for :header do -%> Cases <% end -%> <% form_for(@kase) do |f| %> <%= f.error_messages %> <!-- #START SIDEBAR --> <% content_for :sidebar do -%> <% if @kase.avatar.exists? then %> <%= image_tag @kase.avatar.url %> <% else %> <p style="font-size:smaller"> You can upload an icon for this case that will display here. Usually this would be for the year number icon for easy recognition.</p> <% end %> <div class="js_option"> <h2>Financial Options</h2><p class="finance_showhide"><%= link_to_function "Show","Element.show('finance_showhide');" %> / <%= link_to_function "Hide","Element.hide('finance_showhide');" %></p> </div> <div id="finance_showhide" style="display:none"> <ul id="kases_new_finance"> <li>Invoice Number<span><%= f.text_field :invoicenumber %></span></li> <li>Net Amount<span><%= f.text_field :netamount %></span></li> <li>VAT<span><%= f.text_field :vat %></span></li> <li>Gross Amount<span><%= f.text_field :grossamount %></span></li> <li>Date Closed<span><%= f.text_field :dateclosed %></span></li> <li>Date Paid<span><%= f.text_field :datepaid %></span></li> </ul> </div> <% end -%> <!-- #END SIDEBAR --> <% form_for (@kase), :html => { :multipart => true } do |f| %> <ul id="kases_new"> <li>Job Ref.<span><%= f.text_field :jobno %></span></li> <li>Case Subject<span><%= f.text_field :casesubject %></span></li> <li>Transport<span><%= f.text_field :transport %></span></li> <li>Goods<span><%= f.text_field :goods %></span></li> <li>Date Instructed<span><%= f.date_select :dateinstructed %></span></li> <li>Case Status<span><%= f.select "kase_status", ['Active', 'On Hold', 'Archived', 'Invoice Sent'] %></span></li> <li>Client Reference<span><%= f.text_field :clientref %></span></li> <li>Client Company Name<span><%= f.text_field :clientcompanyname %></span></li> <li>Client Company Address<span><%= f.text_field :clientcompanyaddress %></span></li> <li>Client Company Fax<span><%= f.text_field :clientcompanyfax %></span></li> <li>Case Handler Name<span><%= f.text_field :casehandlername %></span></li> <li>Case Handler Tel<span><%= f.text_field :casehandlertel %></span></li> <li>Case Handler Email<span><%= f.text_field :casehandleremail %></span></li> <li>Claimant Name<span><%= f.text_field :claimantname %></span></li> <li>Claimant Address<span><%= f.text_field :claimantaddress %></span></li> <li>Claimant Contact<span><%= f.text_field :claimantcontact %></span></li> <li>Claimant Tel<span><%= f.text_field :claimanttel %></span></li> <li>Claimant Mob<span><%= f.text_field :claimantmob %></span></li> <li>Claimant Email<span><%= f.text_field :claimantemail %></span></li> <li>Claimant URL<span><%= f.text_field :claimanturl %></span></li> <li>Comments<span><%= f.text_field :comments %></span></li> </ul> <p> <%= f.submit "Create" %> </p> <% end %><% end %> <%= link_to 'Back', kases_path %>

    Read the article

  • Ignoring focusLost(), SWT.Verify, or other SWT listeners in Java code.

    - by Zoot
    Outside of the actual SWT listener, is there any way to ignore a listener via code? For example, I have a java program that implements SWT Text Widgets, and the widgets have: SWT.Verify listeners to filter out unwanted text input. ModifyListeners to wait for the correct number of valid input characters and automatically set focus (using setFocus())to the next valid field, skipping the other text widgets in the tab order. focusLost(FocusEvent) FocusListeners that wait for the loss of focus from the text widget to perform additional input verification and execute an SQL query based on the user input. The issue I run into is clearing the text widgets. One of the widgets has the format "####-##" (Four Numbers, a hyphen, then two numbers) and I have implemented this listener, which is a modified version of SWT Snippet Snippet179. The initial text for this text widget is " - " to provide visual feedback to the user as to the expected format. Only numbers are acceptable input, and the program automatically skips past the hyphen at the appropriate point. /* * This listener was adapted from the "verify input in a template (YYYY/MM/DD)" SWT Code * Snippet (also known as Snippet179), from the Snippets page of the SWT Project. * SWT Code Snippets can be found at: * http://www.eclipse.org/swt/snippets/ */ textBox.addListener(SWT.Verify, new Listener() { boolean ignore; public void handleEvent(Event e) { if (ignore) return; e.doit = false; StringBuffer buffer = new StringBuffer(e.text); char[] chars = new char[buffer.length()]; buffer.getChars(0, chars.length, chars, 0); if (e.character == '\b') { for (int i = e.start; i < e.end; i++) { switch (i) { case 0: /* [x]xxx-xx */ case 1: /* x[x]xx-xx */ case 2: /* xx[x]x-xx */ case 3: /* xxx[x]-xx */ case 5: /* xxxx-[x]x */ case 6: /* xxxx-x[x] */ { buffer.append(' '); break; } case 4: /* xxxx[-]xx */ { buffer.append('-'); break; } default: return; } } textBox.setSelection(e.start, e.start + buffer.length()); ignore = true; textBox.insert(buffer.toString()); ignore = false; textBox.setSelection(e.start, e.start); return; } int start = e.start; if (start > 6) return; int index = 0; for (int i = 0; i < chars.length; i++) { if (start + index == 4) { if (chars[i] == '-') { index++; continue; } buffer.insert(index++, '-'); } if (chars[i] < '0' || '9' < chars[i]) return; index++; } String newText = buffer.toString(); int length = newText.length(); textBox.setSelection(e.start, e.start + length); ignore = true; textBox.insert(newText); ignore = false; /* * After a valid key press, verifying if the input is completed * and passing the cursor to the next text box. */ if (7 == textBox.getCaretPosition()) { /* * Attempting to change the text after receiving a known valid input that has no results (0000-00). */ if ("0000-00".equals(textBox.getText())) { // "0000-00" is the special "Erase Me" code for these text boxes. ignore = true; textBox.setText(" - "); ignore = false; } // Changing focus to a different textBox by using "setFocus()" method. differentTextBox.setFocus(); } } } ); As you can see, the only method I've figured out to clear this text widget from a different point in the code is by assigning "0000-00" textBox.setText("000000") and checking for that input in the listener. When that input is received, the listener changes the text back to " - " (four spaces, a hyphen, then two spaces). There is also a focusLost Listener that parses this text widget for spaces, then in order to avoid unnecessary SQL queries, it clears/resets all fields if the input is invalid (i.e contains spaces). // Adding focus listener to textBox to wait for loss of focus to perform SQL statement. textBox.addFocusListener(new FocusAdapter() { @Override public void focusLost(FocusEvent evt) { // Get the contents of otherTextBox and textBox. (otherTextBox must be <= textBox) String boxFour = otherTextBox.getText(); String boxFive = textBox.getText(); // If either text box has spaces in it, don't perform the search. if (boxFour.contains(" ") || boxFive.contains(" ")) { // Don't perform SQL statements. Debug statement. System.out.println("Tray Position input contains spaces. Ignoring."); //Make all previous results invisible, if any. labels.setVisible(false); differentTextBox.setText(""); labelResults.setVisible(false); } else { //... Perform SQL statement ... } } } ); OK. Often, I use SWT MessageBox widgets in this code to communicate to the user, or wish to change the text widgets back to an empty state after verifying the input. The problem is that messageboxes seem to create a focusLost event, and using the .setText(string) method is subject to SWT.Verify listeners that are present on the text widget. Any suggestions as to selectively ignoring these listeners in code, but keeping them present for all other user input? Thank you in advance for your assistance.

    Read the article

  • Adding data (not only text) to a multi column ListView (WPF)

    - by user811804
    I am working on a WPF application in C# (.NET 4.0) where I have a ListView with a GridView that has two columns. I dynamically want to add rows (in code). My dilemma is that only the first column will have regular text added to it. The second column will have an object that includes a multi column Grid with TextBlocks. (see link http://imageshack.us/photo/my-images/803/listview.png/) If I do what you would normally do when you want to enter text in all columns (ie. DisplayMemberBinding) all I get in the second column is the text "System.Windows.Grid", which obviously isn't what I want. For reference if I just try to add the Grid object (with the TextBlocks) with the code listView1.Items.Add(grid1) (not using DisplayMemberBinding) the object gets added to the second column only (with the first column being blank) and not how it normally works with text where the same text ends up in all columns. I hope my question is detailed enough and any help with this would be much appreciated. EDIT: I have tried the following code, howeever every time I click the button to add a new row every single row gets updated with the same datatemplate. (ie. the second column always shows the same data on every row.) xaml: <Window x:Class="TEST.MainWindow" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" Name="AAA" Title="MainWindow" Height="350" Width="525" Loaded="Window_Loaded"> <Grid Name="grid1"> <Grid.ColumnDefinitions> <ColumnDefinition Width="374*" /> <ColumnDefinition Width="129*" /> </Grid.ColumnDefinitions> <Button Content="Button" Height="23" HorizontalAlignment="Left" Margin="21,12,0,0" Name="button1" VerticalAlignment="Top" Width="75" Grid.Column="1" Click="button1_Click" /> </Grid> code: public partial class MainWindow : Window { ListView listView1 = new ListView(); GridViewColumn viewCol2 = new GridViewColumn(); public MainWindow() { InitializeComponent(); Style style = new Style(typeof(ListViewItem)); style.Setters.Add(new Setter(ListViewItem.HorizontalContentAlignmentProperty, HorizontalAlignment.Stretch)); listView1.ItemContainerStyle = style; GridView gridView1 = new GridView(); listView1.View = gridView1; GridViewColumn viewCol1 = new GridViewColumn(); viewCol1.Header = "Option"; gridView1.Columns.Add(viewCol1); viewCol2.Header = "Value"; gridView1.Columns.Add(viewCol2); grid1.Children.Add(listView1); viewCol1.DisplayMemberBinding = new Binding("Option"); } private void Window_Loaded(object sender, RoutedEventArgs e) { } private void button1_Click(object sender, RoutedEventArgs e) { DataTemplate dataTemplate = new DataTemplate(); FrameworkElementFactory spFactory = new FrameworkElementFactory(typeof(Grid)); Random random = new Random(); int cols = random.Next(1, 6); int full = 100; for (int i = 0; i < cols; i++) { FrameworkElementFactory col1 = new FrameworkElementFactory(typeof(ColumnDefinition)); int partWidth = random.Next(0, full); full -= partWidth; col1.SetValue(ColumnDefinition.WidthProperty, new GridLength(partWidth, GridUnitType.Star)); spFactory.AppendChild(col1); } if (full > 0) { FrameworkElementFactory col1 = new FrameworkElementFactory(typeof(ColumnDefinition)); col1.SetValue(ColumnDefinition.WidthProperty, new GridLength(full, GridUnitType.Star)); spFactory.AppendChild(col1); } for (int i = 0; i < cols; i++) { FrameworkElementFactory text1 = new FrameworkElementFactory(typeof(TextBlock)); SolidColorBrush sb1 = new SolidColorBrush(); switch (i) { case 0: sb1.Color = Colors.Blue; break; case 1: sb1.Color = Colors.Red; break; case 2: sb1.Color = Colors.Yellow; break; case 3: sb1.Color = Colors.Green; break; case 4: sb1.Color = Colors.Purple; break; case 5: sb1.Color = Colors.Pink; break; case 6: sb1.Color = Colors.Brown; break; } text1.SetValue(TextBlock.BackgroundProperty, sb1); text1.SetValue(Grid.ColumnProperty, i); spFactory.AppendChild(text1); } if (full > 0) { FrameworkElementFactory text1 = new FrameworkElementFactory(typeof(TextBlock)); SolidColorBrush sb1 = new SolidColorBrush(Colors.Black); text1.SetValue(TextBlock.BackgroundProperty, sb1); text1.SetValue(Grid.ColumnProperty, cols); spFactory.AppendChild(text1); } dataTemplate.VisualTree = spFactory; viewCol2.CellTemplate = dataTemplate; int rows = listView1.Items.Count + 1; listView1.Items.Add(new { Option = "Row " + rows }); } }

    Read the article

  • login form whith java/sqlite

    - by tuxou
    hi I would like to create a login form for my application with the possibility to add or remove users for an sqlite database, i have created the table users(nam, pass) but i can't unclud it in my login form, it someone could help me this is my login code: import java.awt.*; import java.awt.event.*; import javax.swing.*; public class login extends JFrame { // Variables declaration private JLabel jLabel1; private JLabel jLabel2; private JTextField jTextField1; private JPasswordField jPasswordField1; private JButton jButton1; private JPanel contentPane; // End of variables declaration public login() { super(); create(); this.setVisible(true); } private void create() { jLabel1 = new JLabel(); jLabel2 = new JLabel(); jTextField1 = new JTextField(); jPasswordField1 = new JPasswordField(); jButton1 = new JButton(); contentPane = (JPanel)this.getContentPane(); // // jLabel1 // jLabel1.setHorizontalAlignment(SwingConstants.LEFT); jLabel1.setForeground(new Color(0, 0, 255)); jLabel1.setText("username:"); // // jLabel2 // jLabel2.setHorizontalAlignment(SwingConstants.LEFT); jLabel2.setForeground(new Color(0, 0, 255)); jLabel2.setText("password:"); // // jTextField1 // jTextField1.setForeground(new Color(0, 0, 255)); jTextField1.setSelectedTextColor(new Color(0, 0, 255)); jTextField1.setToolTipText("Enter your username"); jTextField1.addActionListener(new ActionListener() { public void actionPerformed(ActionEvent e) { jTextField1_actionPerformed(e); } }); // // jPasswordField1 // jPasswordField1.setForeground(new Color(0, 0, 255)); jPasswordField1.setToolTipText("Enter your password"); jPasswordField1.addActionListener(new ActionListener() { public void actionPerformed(ActionEvent e) { jPasswordField1_actionPerformed(e); } }); // // jButton1 // jButton1.setBackground(new Color(204, 204, 204)); jButton1.setForeground(new Color(0, 0, 255)); jButton1.setText("Login"); jButton1.addActionListener(new ActionListener() { public void actionPerformed(ActionEvent e) { jButton1_actionPerformed(e); } }); // // contentPane // contentPane.setLayout(null); contentPane.setBorder(BorderFactory.createEtchedBorder()); contentPane.setBackground(new Color(204, 204, 204)); addComponent(contentPane, jLabel1, 5,10,106,18); addComponent(contentPane, jLabel2, 5,47,97,18); addComponent(contentPane, jTextField1, 110,10,183,22); addComponent(contentPane, jPasswordField1, 110,45,183,22); addComponent(contentPane, jButton1, 150,75,83,28); // // login // this.setTitle("Login To Members Area"); this.setLocation(new Point(76, 182)); this.setSize(new Dimension(335, 141)); this.setDefaultCloseOperation(WindowConstants.EXIT_ON_CLOSE); this.setResizable(false); } /** Add Component Without a Layout Manager (Absolute Positioning) */ private void addComponent(Container container,Component c,int x,int y,int width,int height) { c.setBounds(x,y,width,height); container.add(c); } private void jTextField1_actionPerformed(ActionEvent e) { } private void jPasswordField1_actionPerformed(ActionEvent e) { } private void jButton1_actionPerformed(ActionEvent e) { System.out.println("\njButton1_actionPerformed(ActionEvent e) called."); String username = new String(jTextField1.getText()); String password = new String(jPasswordField1.getText()); if(username.equals("") || password.equals("")) // If password and username is empty Do this { jButton1.setEnabled(false); JLabel errorFields = new JLabel("You must enter a username and password to login."); JOptionPane.showMessageDialog(null,errorFields); jTextField1.setText(""); jPasswordField1.setText(""); jButton1.setEnabled(true); this.setVisible(true); } else { JLabel optionLabel = new JLabel("You entered "+username+" as your username. Is this correct?"); int confirm =JOptionPane.showConfirmDialog(null,optionLabel); switch(confirm){ // Switch Case case JOptionPane.YES_OPTION: // Attempt to Login user jButton1.setEnabled(false); // Set button enable to false to prevent 2 login attempts break; case JOptionPane.NO_OPTION: // No Case.(Go back. Set text to 0) jButton1.setEnabled(false); jTextField1.setText(""); jPasswordField1.setText(""); jButton1.setEnabled(true); break; case JOptionPane.CANCEL_OPTION: // Cancel Case.(Go back. Set text to 0) jButton1.setEnabled(false); jTextField1.setText(""); jPasswordField1.setText(""); jButton1.setEnabled(true); break; } // End Switch Case } } public static void main(String[] args) { JFrame.setDefaultLookAndFeelDecorated(true); JDialog.setDefaultLookAndFeelDecorated(true); try { UIManager.setLookAndFeel("com.sun.java.swing.plaf.windows.WindowsLookAndFeel"); } catch (Exception ex) { System.out.println("Failed loading L&F: "); System.out.println(ex); } new login(); }; }

    Read the article

  • i have a win32 windows application and want to capture full screen and remove the border of window d

    - by moon
    win32 windows application and want to capture full screen and remove the border of window displayed any one tell me how can i do so if this window capture the mouse keyboard controls then it will be ideal? // MonitorScreen.cpp : Defines the entry point for the application. // include "stdafx.h" include "MonitorScreen.h" define MAX_LOADSTRING 100 // Global Variables: HINSTANCE hInst; // current instance TCHAR szTitle[MAX_LOADSTRING]; // The title bar text TCHAR szWindowClass[MAX_LOADSTRING]; // the main window class name // Forward declarations of functions included in this code module: ATOM MyRegisterClass(HINSTANCE hInstance); BOOL InitInstance(HINSTANCE, int); LRESULT CALLBACK WndProc(HWND, UINT, WPARAM, LPARAM); INT_PTR CALLBACK About(HWND, UINT, WPARAM, LPARAM); int APIENTRY _tWinMain(HINSTANCE hInstance, HINSTANCE hPrevInstance, LPTSTR lpCmdLine, int nCmdShow) { UNREFERENCED_PARAMETER(hPrevInstance); UNREFERENCED_PARAMETER(lpCmdLine); // TODO: Place code here. MSG msg; HACCEL hAccelTable; // Initialize global strings LoadString(hInstance, IDS_APP_TITLE, szTitle, MAX_LOADSTRING); LoadString(hInstance, IDC_MONITORSCREEN, szWindowClass, MAX_LOADSTRING); MyRegisterClass(hInstance); // Perform application initialization: if (!InitInstance (hInstance, nCmdShow)) { return FALSE; } hAccelTable = LoadAccelerators(hInstance, MAKEINTRESOURCE(IDC_MONITORSCREEN)); // Main message loop: while (GetMessage(&msg, NULL, 0, 0)) { if (!TranslateAccelerator(msg.hwnd, hAccelTable, &msg)) { TranslateMessage(&msg); DispatchMessage(&msg); } } return (int) msg.wParam; } // // FUNCTION: MyRegisterClass() // // PURPOSE: Registers the window class. // // COMMENTS: // // This function and its usage are only necessary if you want this code // to be compatible with Win32 systems prior to the 'RegisterClassEx' // function that was added to Windows 95. It is important to call this function // so that the application will get 'well formed' small icons associated // with it. // ATOM MyRegisterClass(HINSTANCE hInstance) { WNDCLASSEX wcex; int s =sizeof(WNDCLASSEX); wcex.cbSize =sizeof(WNDCLASSEX); wcex.style = DESKTOP_HOOKCONTROL ;//CS_HREDRAW | CS_VREDRAW; wcex.lpfnWndProc = WndProc; wcex.cbClsExtra = 0; wcex.cbWndExtra = 0; wcex.hInstance = NULL;//hInstance; wcex.hIcon = NULL;//LoadIcon(hInstance, MAKEINTRESOURCE(IDI_MONITORSCREEN)); wcex.hCursor = NULL;//LoadCursor(NULL, IDC_ARROW); wcex.hbrBackground = (HBRUSH)(9); wcex.lpszMenuName = NULL;//MAKEINTRESOURCE(IDC_MONITORSCREEN); wcex.lpszClassName = szWindowClass; wcex.hIconSm = NULL;//LoadIcon(wcex.hInstance, MAKEINTRESOURCE(IDI_SMALL)); return RegisterClassEx(&wcex); } // // FUNCTION: InitInstance(HINSTANCE, int) // // PURPOSE: Saves instance handle and creates main window // // COMMENTS: // // In this function, we save the instance handle in a global variable and // create and display the main program window. // BOOL InitInstance(HINSTANCE hInstance, int nCmdShow) { HWND hWnd; hInst = hInstance; // Store instance handle in our global variable hWnd = CreateWindow(szWindowClass, szTitle, WS_OVERLAPPEDWINDOW, CW_USEDEFAULT, 0, CW_USEDEFAULT, 0, NULL, NULL, hInstance, NULL); if (!hWnd) { return FALSE; } ShowWindow(hWnd, nCmdShow); UpdateWindow(hWnd); return TRUE; } // // FUNCTION: WndProc(HWND, UINT, WPARAM, LPARAM) // // PURPOSE: Processes messages for the main window. // // WM_COMMAND - process the application menu // WM_PAINT - Paint the main window // WM_DESTROY - post a quit message and return // // LRESULT CALLBACK WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam) { int wmId, wmEvent; PAINTSTRUCT ps; HDC hdc; switch (message) { case WM_COMMAND: wmId = LOWORD(wParam); wmEvent = HIWORD(wParam); // Parse the menu selections: switch (wmId) { case IDM_ABOUT: DialogBox(hInst, MAKEINTRESOURCE(IDD_ABOUTBOX), hWnd, About); break; case IDM_EXIT: DestroyWindow(hWnd); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } break; case WM_PAINT: hdc = BeginPaint(hWnd, &ps); // TODO: Add any drawing code here... EndPaint(hWnd, &ps); break; case WM_DESTROY: PostQuitMessage(0); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } return 0; } // Message handler for about box. INT_PTR CALLBACK About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam) { UNREFERENCED_PARAMETER(lParam); switch (message) { case WM_INITDIALOG: return (INT_PTR)TRUE; case WM_COMMAND: if (LOWORD(wParam) == IDOK || LOWORD(wParam) == IDCANCEL) { EndDialog(hDlg, LOWORD(wParam)); return (INT_PTR)TRUE; } break; } return (INT_PTR)FALSE; }

    Read the article

  • Work time in fullcalendar [Solution]

    - by Zozo
    Full calendar have no included options to work-time feature (selecting first and last rows in agenda view for any day - where in example company is not working). I managed something like that: viewDisplay: function(view){ $.ajax({ url: 'index.php?r=calendar/Default/worktime', dataType: 'json', success: function(data){ if(view.name=='agendaWeek') selectWorkTime(data, 30, 0, 24, false); else if(view.name=='agendaDay') selectDayWorkTime(data, 30, 0, 24, view, false); } }); } Where index.php?r=calendar/Default/worktime is php file returning json. It looks like that: $arr = array( 'mon' => array('8:00', '17:00'), 'tue' => array('9:00', '15:00'), 'wed' => array('9:30', '19:00'), 'thu' => array('6:00', '14:00'), 'fri' => array('0:00', '24:00'), 'sat' => array('9:00', '14:00'), 'sun' => array() ); foreach ($arr as &$day){ foreach($day as &$hour){ $tmp = explode(':', $hour); $hour = $tmp[0] * 3600 + $tmp[1] * 60; } } print json_encode($arr); and at the end, some functions using for counting and selecting work-time: function selectDayWorkTime(timeArray, slotMinutes, minTime, maxTime, viewObject, showAtHolidays){ var dayname; $('.fc-content').find('.fc-view-agendaWeek').find('.fc-agenda-body') .children('.fc-work-time').remove(); $('.fc-content').find('.fc-view-agendaDay') .find('.fc-work-time-day').removeClass('fc-work-time-day'); switch(viewObject.start.getDay()){ case 1: dayname='mon'; break; case 2: dayname='tue'; break; case 3: dayname='wed'; break; case 4: dayname='thu'; break; case 5: dayname='fri'; break; case 6: dayname='sat'; break; case 0: dayname='sun'; break; } for(var day in timeArray){ if(day == dayname){ if($('.fc-content').find('.fc-view-agendaDay').find('.fc-'+day).attr('class').search('fc-holiday') == -1 || showAtHolidays){ var startBefore = 0; var endBefore = timeArray[day][0] / (60 * slotMinutes) - (minTime * 60) / slotMinutes; var startAfter = timeArray[day][1] / (60 * slotMinutes) - (minTime * 60) / slotMinutes; var endAfter = (maxTime - minTime) * 60 / slotMinutes - 1; for(startBefore; startBefore < endBefore; startBefore++){ $('.fc-view-agendaDay').find('.fc-slot'+startBefore).find('div').addClass('fc-work-time-day'); } for(startAfter; startAfter <= endAfter; startAfter++){ $('.fc-view-agendaDay').find('.fc-slot'+startAfter).find('div').addClass('fc-work-time-day'); } } } } } function selectWorkTime(timeArray, slotMinutes, minTime, maxTime, showAtHolidays){ for(var day in timeArray){ var startBefore = 0; var endBefore = timeArray[day][0] / (60 * slotMinutes) - (minTime * 60) / slotMinutes; var startAfter = timeArray[day][1] / (60 * slotMinutes) - (minTime * 60) / slotMinutes; var endAfter = (maxTime - minTime) * 60 / slotMinutes - 1; if(startBefore > endBefore) endBefore = startBefore; if(startAfter > endAfter) startAfter = endAfter; try{ selectCell(startBefore, endBefore, 'fc-'+day, 'fc-work-time', false, showAtHolidays); selectCell(startAfter, endAfter, 'fc-'+day, 'fc-work-time', true, showAtHolidays); } catch(e){ continue; } } } function selectCell(startRowNo, endRowNo, collClass, cellClass, closeGap, showAtHolidays){ $('.fc-content').find('.fc-view-agendaWeek').find('.fc-agenda-body') .children('.'+cellClass+''+startRowNo+''+collClass).remove(); $('.fc-content').find('.fc-view-agendaDay') .find('.fc-work-time-day').removeClass('fc-work-time-day'); if($('.fc-content').find('.fc-view-agendaWeek').find('.'+collClass).attr('class').search('fc-holiday') == -1 || showAtHolidays){ var width = $('.fc-content').find('.fc-view-agendaWeek') .find('.'+collClass+':last').width(); var height = 0; if(closeGap && (startRowNo != endRowNo)){ height = $('.fc-content').find('.fc-view-agendaWeek') .find('.fc-slot'+ startRowNo).height(); } $('.fc-view-agendaWeek').find('.fc-agenda-body').prepend('<div class="'+cellClass+' ' + ''+cellClass+''+startRowNo+''+collClass+'"></div>'); $('.'+cellClass).width(width - 2); height += $('.fc-content').find('.fc-view-agendaWeek') .find('.fc-slot'+ endRowNo).position().top - $('.fc-content').find('.fc-view-agendaWeek') .find('.fc-slot'+ startRowNo).position().top; $('.'+cellClass+''+startRowNo+''+collClass).height(height); $('.'+cellClass+''+startRowNo+''+collClass) .css('margin-top', $('.fc-content').find('.fc-view-agendaWeek') .find('.fc-slot'+ startRowNo).position().top); $('.'+cellClass+''+startRowNo+''+collClass) .css('margin-left', $('.fc-content').find('.fc-view-agendaWeek') .find('.'+collClass+':last').offset().left - width / 2); } } Don't forget about CSS: .fc-work-time-day{ background-color: yellow; opacity: 0.3; filter: alpha(opacity=30); /* for IE */ } .fc-work-time{ position: absolute; background-color: yellow; z-index:10; margin: 0; padding: 0; text-align: left; z-index: 0; opacity: 0.3; filter: alpha(opacity=30); /* for IE */ } So, I've got some questions about - is the other way to make the same, but no using absolute div's in agendaWeek? And... How can I get in viewDisplay function actual slotMinutes, minTime and maxTime

    Read the article

  • how to use a class method as a WIN32 application callback method (WINPROC)... Error static struct HI

    - by numerical25
    I am receiving errors and at the same time trying to make this work so please read what I got to say. Thanks.... I am creating a c++ application and majority of the application is encapsulated into a class. That means that my WinProc function is a static class method that I use as my call back method for my win32 application. The problem is that since I created that as a win32 application, every class member I use inside that method has to be static as well. Including my HINSTANCE class which I use inside of it. Now I receive this error error LNK2001: unresolved external symbol "public: static struct HINSTANCE__ I need to figure out how to make this all work and below is my class declaration. My static member static HINSTANCE m_hInst is causing the error I believe. #pragma once #include "stdafx.h" #include "resource.h" #define MAX_LOADSTRING 100 class RenderEngine { protected: int m_width; int m_height; ATOM RegisterEngineClass(); public: static HINSTANCE m_hInst; //<------ This is causing the error HWND m_hWnd; int m_nCmdShow; TCHAR m_szTitle[MAX_LOADSTRING]; // The title bar text TCHAR m_szWindowClass[MAX_LOADSTRING]; // the main window class name bool InitWindow(); bool InitDirectX(); bool InitInstance(); //static functions static LRESULT CALLBACK WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam); static INT_PTR CALLBACK About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam); int Run(); }; Below is the implementation #include "stdafx.h" #include "RenderEngine.h" bool RenderEngine::InitWindow() { RenderEngine::m_hInst = NULL; // Initialize global strings LoadString(m_hInst, IDS_APP_TITLE, m_szTitle, MAX_LOADSTRING); LoadString(m_hInst, IDC_RENDERENGINE, m_szWindowClass, MAX_LOADSTRING); if(!RegisterEngineClass()) { return false; } if(!InitInstance()) { return false; } return true; } ATOM RenderEngine::RegisterEngineClass() { WNDCLASSEX wcex; wcex.cbSize = sizeof(WNDCLASSEX); wcex.style = CS_HREDRAW | CS_VREDRAW; wcex.lpfnWndProc = RenderEngine::WndProc; wcex.cbClsExtra = 0; wcex.cbWndExtra = 0; wcex.hInstance = m_hInst; wcex.hIcon = LoadIcon(m_hInst, MAKEINTRESOURCE(IDI_RENDERENGINE)); wcex.hCursor = LoadCursor(NULL, IDC_ARROW); wcex.hbrBackground = (HBRUSH)(COLOR_WINDOW+1); wcex.lpszMenuName = MAKEINTRESOURCE(IDC_RENDERENGINE); wcex.lpszClassName = m_szWindowClass; wcex.hIconSm = LoadIcon(wcex.hInstance, MAKEINTRESOURCE(IDI_SMALL)); return RegisterClassEx(&wcex); } LRESULT CALLBACK RenderEngine::WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam) { int wmId, wmEvent; PAINTSTRUCT ps; HDC hdc; switch (message) { case WM_COMMAND: wmId = LOWORD(wParam); wmEvent = HIWORD(wParam); // Parse the menu selections: switch (wmId) { case IDM_ABOUT: DialogBox(m_hInst, MAKEINTRESOURCE(IDD_ABOUTBOX), hWnd, About); break; case IDM_EXIT: DestroyWindow(hWnd); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } break; case WM_PAINT: hdc = BeginPaint(hWnd, &ps); // TODO: Add any drawing code here... EndPaint(hWnd, &ps); break; case WM_DESTROY: PostQuitMessage(0); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } return 0; } bool RenderEngine::InitInstance() { m_hWnd = NULL; m_hWnd = CreateWindow(m_szWindowClass, m_szTitle, WS_OVERLAPPEDWINDOW, CW_USEDEFAULT, 0, CW_USEDEFAULT, 0, NULL, NULL, m_hInst, NULL); if (!m_hWnd) { return FALSE; } if(!ShowWindow(m_hWnd, m_nCmdShow)) { return false; } UpdateWindow(m_hWnd); return true; } // Message handler for about box. INT_PTR CALLBACK RenderEngine::About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam) { UNREFERENCED_PARAMETER(lParam); switch (message) { case WM_INITDIALOG: return (INT_PTR)TRUE; case WM_COMMAND: if (LOWORD(wParam) == IDOK || LOWORD(wParam) == IDCANCEL) { EndDialog(hDlg, LOWORD(wParam)); return (INT_PTR)TRUE; } break; } return (INT_PTR)FALSE; } int RenderEngine::Run() { MSG msg; HACCEL hAccelTable; hAccelTable = LoadAccelerators(m_hInst, MAKEINTRESOURCE(IDC_RENDERENGINE)); // Main message loop: while (GetMessage(&msg, NULL, 0, 0)) { if (!TranslateAccelerator(msg.hwnd, hAccelTable, &msg)) { TranslateMessage(&msg); DispatchMessage(&msg); } } return (int) msg.wParam; } and below is the code being used within the WinMain RenderEngine go; int APIENTRY _tWinMain(HINSTANCE hInstance, HINSTANCE hPrevInstance, LPTSTR lpCmdLine, int nCmdShow) { UNREFERENCED_PARAMETER(hPrevInstance); UNREFERENCED_PARAMETER(lpCmdLine); // TODO: Place code here. RenderEngine::m_hInst = hInstance; go.m_nCmdShow = nCmdShow; if(!go.InitWindow()) { return 0; } go.Run(); return 0; } If anything does not make any sense, then I apologize, I am a newb. Thanks for the help!!

    Read the article

  • my window's handle is unused and cannot be evaluated

    - by numerical25
    I am trying to encapsulate my Win32 application into a class. My problem occurs when trying to initiate my primary window for the application below is my declaration and implementation... I notice the issue within my class method InitInstance(); declaration #pragma once #include "stdafx.h" #include "resource.h" #define MAX_LOADSTRING 100 class RenderEngine { protected: int m_width; int m_height; ATOM RegisterEngineClass(); public: static HINSTANCE m_hInst; HWND m_hWnd; int m_nCmdShow; TCHAR m_szTitle[MAX_LOADSTRING]; // The title bar text TCHAR m_szWindowClass[MAX_LOADSTRING]; // the main window class name bool InitWindow(); bool InitDirectX(); bool InitInstance(); //static functions static LRESULT CALLBACK WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam); static INT_PTR CALLBACK About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam); int Run(); }; implementation #include "stdafx.h" #include "RenderEngine.h" HINSTANCE RenderEngine::m_hInst = NULL; bool RenderEngine::InitWindow() { RenderEngine::m_hInst = NULL; // Initialize global strings LoadString(m_hInst, IDS_APP_TITLE, m_szTitle, MAX_LOADSTRING); LoadString(m_hInst, IDC_RENDERENGINE, m_szWindowClass, MAX_LOADSTRING); if(!RegisterEngineClass()) { return false; } if(!InitInstance()) { return false; } return true; } ATOM RenderEngine::RegisterEngineClass() { WNDCLASSEX wcex; wcex.cbSize = sizeof(WNDCLASSEX); wcex.style = CS_HREDRAW | CS_VREDRAW; wcex.lpfnWndProc = RenderEngine::WndProc; wcex.cbClsExtra = 0; wcex.cbWndExtra = 0; wcex.hInstance = m_hInst; wcex.hIcon = LoadIcon(m_hInst, MAKEINTRESOURCE(IDI_RENDERENGINE)); wcex.hCursor = LoadCursor(NULL, IDC_ARROW); wcex.hbrBackground = (HBRUSH)(COLOR_WINDOW+1); wcex.lpszMenuName = MAKEINTRESOURCE(IDC_RENDERENGINE); wcex.lpszClassName = m_szWindowClass; wcex.hIconSm = LoadIcon(wcex.hInstance, MAKEINTRESOURCE(IDI_SMALL)); return RegisterClassEx(&wcex); } LRESULT CALLBACK RenderEngine::WndProc(HWND hWnd, UINT message, WPARAM wParam, LPARAM lParam) { int wmId, wmEvent; PAINTSTRUCT ps; HDC hdc; switch (message) { case WM_COMMAND: wmId = LOWORD(wParam); wmEvent = HIWORD(wParam); // Parse the menu selections: switch (wmId) { case IDM_ABOUT: DialogBox(m_hInst, MAKEINTRESOURCE(IDD_ABOUTBOX), hWnd, About); break; case IDM_EXIT: DestroyWindow(hWnd); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } break; case WM_PAINT: hdc = BeginPaint(hWnd, &ps); // TODO: Add any drawing code here... EndPaint(hWnd, &ps); break; case WM_DESTROY: PostQuitMessage(0); break; default: return DefWindowProc(hWnd, message, wParam, lParam); } return 0; } bool RenderEngine::InitInstance() { m_hWnd = NULL;// When I step into my code it says on this line 0x000000 unused = ??? expression cannot be evaluated m_hWnd = CreateWindow(m_szWindowClass, m_szTitle, WS_OVERLAPPEDWINDOW, CW_USEDEFAULT, 0, CW_USEDEFAULT, 0, NULL, NULL, m_hInst, NULL); if (!m_hWnd)// At this point, memory has been allocated unused = ??. It steps over this { return FALSE; } if(!ShowWindow(m_hWnd, m_nCmdShow))// m_nCmdShow = 1 and m_hWnd is still unused and expression {//Still cannot be evaluated. This statement is true. and shuts down. return false; } UpdateWindow(m_hWnd); return true; } // Message handler for about box. INT_PTR CALLBACK RenderEngine::About(HWND hDlg, UINT message, WPARAM wParam, LPARAM lParam) { UNREFERENCED_PARAMETER(lParam); switch (message) { case WM_INITDIALOG: return (INT_PTR)TRUE; case WM_COMMAND: if (LOWORD(wParam) == IDOK || LOWORD(wParam) == IDCANCEL) { EndDialog(hDlg, LOWORD(wParam)); return (INT_PTR)TRUE; } break; } return (INT_PTR)FALSE; } int RenderEngine::Run() { MSG msg; HACCEL hAccelTable; hAccelTable = LoadAccelerators(m_hInst, MAKEINTRESOURCE(IDC_RENDERENGINE)); // Main message loop: while (GetMessage(&msg, NULL, 0, 0)) { if (!TranslateAccelerator(msg.hwnd, hAccelTable, &msg)) { TranslateMessage(&msg); DispatchMessage(&msg); } } return (int) msg.wParam; } and my winMain function that calls the class // RenderEngine.cpp : Defines the entry point for the application. #include "stdafx.h" #include "RenderEngine.h" // Global Variables: RenderEngine go; int APIENTRY _tWinMain(HINSTANCE hInstance, HINSTANCE hPrevInstance, LPTSTR lpCmdLine, int nCmdShow) { UNREFERENCED_PARAMETER(hPrevInstance); UNREFERENCED_PARAMETER(lpCmdLine); // TODO: Place code here. RenderEngine::m_hInst = hInstance; go.m_nCmdShow = nCmdShow; if(!go.InitWindow()) { return 0; } go.Run(); return 0; }

    Read the article

  • Export data to Excel from Silverlight/WPF DataGrid

    - by outcoldman
    Data export from DataGrid to Excel is very common task, and it can be solved with different ways, and chosen way depend on kind of app which you are design. If you are developing app for enterprise, and it will be installed on several computes, then you can to advance a claim (system requirements) with which your app will be work for client. Or customer will advance system requirements on which your app should work. In this case you can use COM for export (use infrastructure of Excel or OpenOffice). This approach will give you much more flexibility and give you possibility to use all features of Excel app. About this approach I’ll speak below. Other way – your app is for personal use, it can be installed on any home computer, in this case it is not good to ask user to install MS Office or OpenOffice just for using your app. In this way you can use foreign tools for export, or export to xml/html format which MS Office can read (this approach used by JIRA). But in this case will be more difficult to satisfy user tasks, like create document with landscape rotation and with defined fields for printing. At this article I'll show you how to work with Excel object from .NET 4 and Silverlight 4 with dynamic objects and give you an approach which allow you to export data from DataGrid Silverlight and WPF controls. Read more...

    Read the article

  • Why is there a /etc/init.d/mysql file on this Slackware machine? How could it have gotten there?

    - by jasonspiro
    A client of my IT-consulting service owns a web-development shop. He's been having problems with a Slackware 12.0 server running MySQL 5.0.67. The machine was set up by the client's sysadmin, who left on bad terms. My client no longer employs a sysadmin. As far as I can tell, the only copy of MySQL that's installed is the one described in /var/log/packages/mysql-5.0.67-i486-1: PACKAGE NAME: mysql-5.0.67-i486-1 COMPRESSED PACKAGE SIZE: 16828 K UNCOMPRESSED PACKAGE SIZE: 33840 K PACKAGE LOCATION: /var/slapt-get/archives/./slackware/ap/mysql-5.0.67-i486-1.tgz PACKAGE DESCRIPTION: mysql: mysql (SQL-based relational database server) mysql: mysql: MySQL is a fast, multi-threaded, multi-user, and robust SQL mysql: (Structured Query Language) database server. It comes with a nice API mysql: which makes it easy to integrate into other applications. mysql: mysql: The home page for MySQL is http://www.mysql.com/ mysql: mysql: mysql: mysql: FILE LIST: ./ var/ var/lib/ var/lib/mysql/ var/run/ var/run/mysql/ install/ install/doinst.sh install/slack-desc usr/ usr/include/ usr/include/mysql/ usr/include/mysql/my_alloc.h usr/include/mysql/sql_common.h usr/include/mysql/my_dbug.h usr/include/mysql/errmsg.h usr/include/mysql/my_pthread.h usr/include/mysql/my_list.h usr/include/mysql/mysql.h usr/include/mysql/sslopt-vars.h usr/include/mysql/my_config.h usr/include/mysql/mysql_com.h usr/include/mysql/m_string.h usr/include/mysql/sslopt-case.h usr/include/mysql/my_xml.h usr/include/mysql/sql_state.h usr/include/mysql/my_global.h usr/include/mysql/my_sys.h usr/include/mysql/mysqld_ername.h usr/include/mysql/mysqld_error.h usr/include/mysql/sslopt-longopts.h usr/include/mysql/keycache.h usr/include/mysql/my_net.h usr/include/mysql/mysql_version.h usr/include/mysql/my_no_pthread.h usr/include/mysql/decimal.h usr/include/mysql/readline.h usr/include/mysql/my_attribute.h usr/include/mysql/typelib.h usr/include/mysql/my_dir.h usr/include/mysql/raid.h usr/include/mysql/m_ctype.h usr/include/mysql/mysql_embed.h usr/include/mysql/mysql_time.h usr/include/mysql/my_getopt.h usr/lib/ usr/lib/mysql/ usr/lib/mysql/libmysqlclient_r.so.15.0.0 usr/lib/mysql/libmysqlclient_r.la usr/lib/mysql/libmyisammrg.a usr/lib/mysql/libmystrings.a usr/lib/mysql/libmyisam.a usr/lib/mysql/libmysqlclient.so.15.0.0 usr/lib/mysql/libmysqlclient_r.a usr/lib/mysql/libmysqlclient.a usr/lib/mysql/libheap.a usr/lib/mysql/libvio.a usr/lib/mysql/libmysqlclient.la usr/lib/mysql/libmysys.a usr/lib/mysql/libdbug.a usr/bin/ usr/bin/comp_err usr/bin/my_print_defaults usr/bin/resolve_stack_dump usr/bin/msql2mysql usr/bin/mysqltestmanager-pwgen usr/bin/myisampack usr/bin/replace usr/bin/mysqld_multi usr/bin/mysqlaccess usr/bin/mysql_install_db usr/bin/innochecksum usr/bin/myisam_ftdump usr/bin/mysqlcheck usr/bin/mysqltest usr/bin/mysql_upgrade_shell usr/bin/mysql_secure_installation usr/bin/mysql_fix_extensions usr/bin/mysqld_safe usr/bin/mysql_explain_log usr/bin/mysqlimport usr/bin/myisamlog usr/bin/mysql_tzinfo_to_sql usr/bin/mysql_upgrade usr/bin/mysqltestmanager usr/bin/mysql_fix_privilege_tables usr/bin/mysql_find_rows usr/bin/mysql_convert_table_format usr/bin/mysqltestmanagerc usr/bin/mysqlhotcopy usr/bin/mysqldump usr/bin/mysqlshow usr/bin/mysqlbug usr/bin/mysql_config usr/bin/mysqldumpslow usr/bin/mysql_waitpid usr/bin/mysqlbinlog usr/bin/mysql_client_test usr/bin/perror usr/bin/mysql usr/bin/myisamchk usr/bin/mysql_setpermission usr/bin/mysqladmin usr/bin/mysql_zap usr/bin/mysql_tableinfo usr/bin/resolveip usr/share/ usr/share/mysql/ usr/share/mysql/errmsg.txt usr/share/mysql/swedish/ usr/share/mysql/swedish/errmsg.sys usr/share/mysql/mysql_system_tables_data.sql usr/share/mysql/mysql.server usr/share/mysql/hungarian/ usr/share/mysql/hungarian/errmsg.sys usr/share/mysql/norwegian/ usr/share/mysql/norwegian/errmsg.sys usr/share/mysql/slovak/ usr/share/mysql/slovak/errmsg.sys usr/share/mysql/spanish/ usr/share/mysql/spanish/errmsg.sys usr/share/mysql/polish/ usr/share/mysql/polish/errmsg.sys usr/share/mysql/ukrainian/ usr/share/mysql/ukrainian/errmsg.sys usr/share/mysql/danish/ usr/share/mysql/danish/errmsg.sys usr/share/mysql/romanian/ usr/share/mysql/romanian/errmsg.sys usr/share/mysql/english/ usr/share/mysql/english/errmsg.sys usr/share/mysql/charsets/ usr/share/mysql/charsets/latin2.xml usr/share/mysql/charsets/greek.xml usr/share/mysql/charsets/koi8r.xml usr/share/mysql/charsets/latin1.xml usr/share/mysql/charsets/cp866.xml usr/share/mysql/charsets/geostd8.xml usr/share/mysql/charsets/cp1250.xml usr/share/mysql/charsets/koi8u.xml usr/share/mysql/charsets/cp852.xml usr/share/mysql/charsets/hebrew.xml usr/share/mysql/charsets/latin7.xml usr/share/mysql/charsets/README usr/share/mysql/charsets/ascii.xml usr/share/mysql/charsets/cp1251.xml usr/share/mysql/charsets/macce.xml usr/share/mysql/charsets/latin5.xml usr/share/mysql/charsets/Index.xml usr/share/mysql/charsets/macroman.xml usr/share/mysql/charsets/cp1256.xml usr/share/mysql/charsets/keybcs2.xml usr/share/mysql/charsets/swe7.xml usr/share/mysql/charsets/armscii8.xml usr/share/mysql/charsets/dec8.xml usr/share/mysql/charsets/cp1257.xml usr/share/mysql/charsets/hp8.xml usr/share/mysql/charsets/cp850.xml usr/share/mysql/korean/ usr/share/mysql/korean/errmsg.sys usr/share/mysql/german/ usr/share/mysql/german/errmsg.sys usr/share/mysql/mi_test_all.res usr/share/mysql/greek/ usr/share/mysql/greek/errmsg.sys usr/share/mysql/french/ usr/share/mysql/french/errmsg.sys usr/share/mysql/mysql_fix_privilege_tables.sql usr/share/mysql/dutch/ usr/share/mysql/dutch/errmsg.sys usr/share/mysql/serbian/ usr/share/mysql/serbian/errmsg.sys usr/share/mysql/mysql_system_tables.sql usr/share/mysql/my-huge.cnf usr/share/mysql/portuguese/ usr/share/mysql/portuguese/errmsg.sys usr/share/mysql/japanese/ usr/share/mysql/japanese/errmsg.sys usr/share/mysql/mysql_test_data_timezone.sql usr/share/mysql/russian/ usr/share/mysql/russian/errmsg.sys usr/share/mysql/czech/ usr/share/mysql/czech/errmsg.sys usr/share/mysql/fill_help_tables.sql usr/share/mysql/estonian/ usr/share/mysql/estonian/errmsg.sys usr/share/mysql/my-medium.cnf usr/share/mysql/norwegian-ny/ usr/share/mysql/norwegian-ny/errmsg.sys usr/share/mysql/my-small.cnf usr/share/mysql/mysql-log-rotate usr/share/mysql/italian/ usr/share/mysql/italian/errmsg.sys usr/share/mysql/my-large.cnf usr/share/mysql/ndb-config-2-node.ini usr/share/mysql/binary-configure usr/share/mysql/mi_test_all usr/share/mysql/mysqld_multi.server usr/share/mysql/my-innodb-heavy-4G.cnf usr/doc/ usr/doc/mysql-5.0.67/ usr/doc/mysql-5.0.67/README usr/doc/mysql-5.0.67/Docs/ usr/doc/mysql-5.0.67/Docs/INSTALL-BINARY usr/doc/mysql-5.0.67/COPYING usr/info/ usr/info/mysql.info.gz usr/libexec/ usr/libexec/mysqld usr/libexec/mysqlmanager usr/man/ usr/man/man8/ usr/man/man8/mysqlmanager.8.gz usr/man/man8/mysqld.8.gz usr/man/man1/ usr/man/man1/mysql_zap.1.gz usr/man/man1/mysql_setpermission.1.gz usr/man/man1/mysql_tzinfo_to_sql.1.gz usr/man/man1/msql2mysql.1.gz usr/man/man1/mysql_tableinfo.1.gz usr/man/man1/mysql_explain_log.1.gz usr/man/man1/mysqlcheck.1.gz usr/man/man1/comp_err.1.gz usr/man/man1/my_print_defaults.1.gz usr/man/man1/mysqlbinlog.1.gz usr/man/man1/myisam_ftdump.1.gz usr/man/man1/mysql_upgrade.1.gz usr/man/man1/mysql.1.gz usr/man/man1/mysql_client_test.1.gz usr/man/man1/resolve_stack_dump.1.gz usr/man/man1/mysql_fix_extensions.1.gz usr/man/man1/mysqlmanagerc.1.gz usr/man/man1/mysql_config.1.gz usr/man/man1/mysqlshow.1.gz usr/man/man1/myisamlog.1.gz usr/man/man1/replace.1.gz usr/man/man1/mysqlmanager-pwgen.1.gz usr/man/man1/mysqltest.1.gz usr/man/man1/innochecksum.1.gz usr/man/man1/mysqladmin.1.gz usr/man/man1/perror.1.gz usr/man/man1/mysql_waitpid.1.gz usr/man/man1/mysql_convert_table_format.1.gz usr/man/man1/mysqlman.1.gz usr/man/man1/mysqlimport.1.gz usr/man/man1/mysqlbug.1.gz usr/man/man1/mysql_find_rows.1.gz usr/man/man1/myisampack.1.gz usr/man/man1/myisamchk.1.gz usr/man/man1/mysql_fix_privilege_tables.1.gz usr/man/man1/mysql-stress-test.pl.1.gz usr/man/man1/resolveip.1.gz usr/man/man1/make_win_bin_dist.1.gz usr/man/man1/mysqlhotcopy.1.gz usr/man/man1/mysqld_multi.1.gz usr/man/man1/safe_mysqld.1.gz usr/man/man1/mysql_secure_installation.1.gz usr/man/man1/mysql_install_db.1.gz usr/man/man1/mysqldump.1.gz usr/man/man1/mysql-test-run.pl.1.gz usr/man/man1/mysqld_safe.1.gz usr/man/man1/mysqlaccess.1.gz usr/man/man1/mysql.server.1.gz usr/man/man1/make_win_src_distribution.1.gz etc/ etc/rc.d/ etc/rc.d/rc.mysqld.new etc/my-huge.cnf etc/my-medium.cnf etc/my-small.cnf etc/my-large.cnf /etc/rc.d/rc.mysqld is an ordinary Slackware-type start/stop script: #!/bin/sh # Start/stop/restart mysqld. # # Copyright 2003 Patrick J. Volkerding, Concord, CA # Copyright 2003 Slackware Linux, Inc., Concord, CA # # This program comes with NO WARRANTY, to the extent permitted by law. # You may redistribute copies of this program under the terms of the # GNU General Public License. # To start MySQL automatically at boot, be sure this script is executable: # chmod 755 /etc/rc.d/rc.mysqld # Before you can run MySQL, you must have a database. To install an initial # database, do this as root: # # su - mysql # mysql_install_db # # Note that step one is becoming the mysql user. It's important to do this # before making any changes to the database, or mysqld won't be able to write # to it later (this can be fixed with 'chown -R mysql.mysql /var/lib/mysql'). # To allow outside connections to the database comment out the next line. # If you don't need incoming network connections, then leave the line # uncommented to improve system security. #SKIP="--skip-networking" # Start mysqld: mysqld_start() { if [ -x /usr/bin/mysqld_safe ]; then # If there is an old PID file (no mysqld running), clean it up: if [ -r /var/run/mysql/mysql.pid ]; then if ! ps axc | grep mysqld 1> /dev/null 2> /dev/null ; then echo "Cleaning up old /var/run/mysql/mysql.pid." rm -f /var/run/mysql/mysql.pid fi fi /usr/bin/mysqld_safe --datadir=/var/lib/mysql --pid-file=/var/run/mysql/mysql.pid $SKIP & fi } # Stop mysqld: mysqld_stop() { # If there is no PID file, ignore this request... if [ -r /var/run/mysql/mysql.pid ]; then killall mysqld # Wait at least one minute for it to exit, as we don't know how big the DB is... for second in 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 \ 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 60 ; do if [ ! -r /var/run/mysql/mysql.pid ]; then break; fi sleep 1 done if [ "$second" = "60" ]; then echo "WARNING: Gave up waiting for mysqld to exit!" sleep 15 fi fi } # Restart mysqld: mysqld_restart() { mysqld_stop mysqld_start } case "$1" in 'start') mysqld_start ;; 'stop') mysqld_stop ;; 'restart') mysqld_restart ;; *) echo "usage $0 start|stop|restart" esac But there's also an unexpected init script on the machine, named /etc/init.d/mysql: #!/bin/sh # Copyright Abandoned 1996 TCX DataKonsult AB & Monty Program KB & Detron HB # This file is public domain and comes with NO WARRANTY of any kind # MySQL daemon start/stop script. # Usually this is put in /etc/init.d (at least on machines SYSV R4 based # systems) and linked to /etc/rc3.d/S99mysql and /etc/rc0.d/K01mysql. # When this is done the mysql server will be started when the machine is # started and shut down when the systems goes down. # Comments to support chkconfig on RedHat Linux # chkconfig: 2345 64 36 # description: A very fast and reliable SQL database engine. # Comments to support LSB init script conventions ### BEGIN INIT INFO # Provides: mysql # Required-Start: $local_fs $network $remote_fs # Should-Start: ypbind nscd ldap ntpd xntpd # Required-Stop: $local_fs $network $remote_fs # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: start and stop MySQL # Description: MySQL is a very fast and reliable SQL database engine. ### END INIT INFO # If you install MySQL on some other places than /usr, then you # have to do one of the following things for this script to work: # # - Run this script from within the MySQL installation directory # - Create a /etc/my.cnf file with the following information: # [mysqld] # basedir=<path-to-mysql-installation-directory> # - Add the above to any other configuration file (for example ~/.my.ini) # and copy my_print_defaults to /usr/bin # - Add the path to the mysql-installation-directory to the basedir variable # below. # # If you want to affect other MySQL variables, you should make your changes # in the /etc/my.cnf, ~/.my.cnf or other MySQL configuration files. # If you change base dir, you must also change datadir. These may get # overwritten by settings in the MySQL configuration files. #basedir= #datadir= # Default value, in seconds, afterwhich the script should timeout waiting # for server start. # Value here is overriden by value in my.cnf. # 0 means don't wait at all # Negative numbers mean to wait indefinitely service_startup_timeout=900 # The following variables are only set for letting mysql.server find things. # Set some defaults pid_file=/var/run/mysql/mysql.pid server_pid_file=/var/run/mysql/mysql.pid use_mysqld_safe=1 user=mysql if test -z "$basedir" then basedir=/usr bindir=/usr/bin if test -z "$datadir" then datadir=/var/lib/mysql fi sbindir=/usr/sbin libexecdir=/usr/libexec else bindir="$basedir/bin" if test -z "$datadir" then datadir="$basedir/data" fi sbindir="$basedir/sbin" libexecdir="$basedir/libexec" fi # datadir_set is used to determine if datadir was set (and so should be # *not* set inside of the --basedir= handler.) datadir_set= # # Use LSB init script functions for printing messages, if possible # lsb_functions="/lib/lsb/init-functions" if test -f $lsb_functions ; then . $lsb_functions else log_success_msg() { echo " SUCCESS! $@" } log_failure_msg() { echo " ERROR! $@" } fi PATH=/sbin:/usr/sbin:/bin:/usr/bin:$basedir/bin export PATH mode=$1 # start or stop shift other_args="$*" # uncommon, but needed when called from an RPM upgrade action # Expected: "--skip-networking --skip-grant-tables" # They are not checked here, intentionally, as it is the resposibility # of the "spec" file author to give correct arguments only. case `echo "testing\c"`,`echo -n testing` in *c*,-n*) echo_n= echo_c= ;; *c*,*) echo_n=-n echo_c= ;; *) echo_n= echo_c='\c' ;; esac parse_server_arguments() { for arg do case "$arg" in --basedir=*) basedir=`echo "$arg" | sed -e 's/^[^=]*=//'` bindir="$basedir/bin" if test -z "$datadir_set"; then datadir="$basedir/data" fi sbindir="$basedir/sbin" libexecdir="$basedir/libexec" ;; --datadir=*) datadir=`echo "$arg" | sed -e 's/^[^=]*=//'` datadir_set=1 ;; --user=*) user=`echo "$arg" | sed -e 's/^[^=]*=//'` ;; --pid-file=*) server_pid_file=`echo "$arg" | sed -e 's/^[^=]*=//'` ;; --service-startup-timeout=*) service_startup_timeout=`echo "$arg" | sed -e 's/^[^=]*=//'` ;; --use-mysqld_safe) use_mysqld_safe=1;; --use-manager) use_mysqld_safe=0;; esac done } parse_manager_arguments() { for arg do case "$arg" in --pid-file=*) pid_file=`echo "$arg" | sed -e 's/^[^=]*=//'` ;; --user=*) user=`echo "$arg" | sed -e 's/^[^=]*=//'` ;; esac done } wait_for_pid () { verb="$1" manager_pid="$2" # process ID of the program operating on the pid-file i=0 avoid_race_condition="by checking again" while test $i -ne $service_startup_timeout ; do case "$verb" in 'created') # wait for a PID-file to pop into existence. test -s $pid_file && i='' && break ;; 'removed') # wait for this PID-file to disappear test ! -s $pid_file && i='' && break ;; *) echo "wait_for_pid () usage: wait_for_pid created|removed manager_pid" exit 1 ;; esac # if manager isn't running, then pid-file will never be updated if test -n "$manager_pid"; then if kill -0 "$manager_pid" 2>/dev/null; then : # the manager still runs else # The manager may have exited between the last pid-file check and now. if test -n "$avoid_race_condition"; then avoid_race_condition="" continue # Check again. fi # there's nothing that will affect the file. log_failure_msg "Manager of pid-file quit without updating file." return 1 # not waiting any more. fi fi echo $echo_n ".$echo_c" i=`expr $i + 1` sleep 1 done if test -z "$i" ; then log_success_msg return 0 else log_failure_msg return 1 fi } # Get arguments from the my.cnf file, # the only group, which is read from now on is [mysqld] if test -x ./bin/my_print_defaults then print_defaults="./bin/my_print_defaults" elif test -x $bindir/my_print_defaults then print_defaults="$bindir/my_print_defaults" elif test -x $bindir/mysql_print_defaults then print_defaults="$bindir/mysql_print_defaults" else # Try to find basedir in /etc/my.cnf conf=/etc/my.cnf print_defaults= if test -r $conf then subpat='^[^=]*basedir[^=]*=\(.*\)$' dirs=`sed -e "/$subpat/!d" -e 's//\1/' $conf` for d in $dirs do d=`echo $d | sed -e 's/[ ]//g'` if test -x "$d/bin/my_print_defaults" then print_defaults="$d/bin/my_print_defaults" break fi if test -x "$d/bin/mysql_print_defaults" then print_defaults="$d/bin/mysql_print_defaults" break fi done fi # Hope it's in the PATH ... but I doubt it test -z "$print_defaults" && print_defaults="my_print_defaults" fi # # Read defaults file from 'basedir'. If there is no defaults file there # check if it's in the old (depricated) place (datadir) and read it from there # extra_args="" if test -r "$basedir/my.cnf" then extra_args="-e $basedir/my.cnf" else if test -r "$datadir/my.cnf" then extra_args="-e $datadir/my.cnf" fi fi parse_server_arguments `$print_defaults $extra_args mysqld server mysql_server mysql.server` # Look for the pidfile parse_manager_arguments `$print_defaults $extra_args manager` # # Set pid file if not given # if test -z "$pid_file" then pid_file=$datadir/mysqlmanager-`/bin/hostname`.pid else case "$pid_file" in /* ) ;; * ) pid_file="$datadir/$pid_file" ;; esac fi if test -z "$server_pid_file" then server_pid_file=$datadir/`/bin/hostname`.pid else case "$server_pid_file" in /* ) ;; * ) server_pid_file="$datadir/$server_pid_file" ;; esac fi case "$mode" in 'start') # Start daemon # Safeguard (relative paths, core dumps..) cd $basedir manager=$bindir/mysqlmanager if test -x $libexecdir/mysqlmanager then manager=$libexecdir/mysqlmanager elif test -x $sbindir/mysqlmanager then manager=$sbindir/mysqlmanager fi echo $echo_n "Starting MySQL" if test -x $manager -a "$use_mysqld_safe" = "0" then if test -n "$other_args" then log_failure_msg "MySQL manager does not support options '$other_args'" exit 1 fi # Give extra arguments to mysqld with the my.cnf file. This script may # be overwritten at next upgrade. $manager --user=$user --pid-file=$pid_file >/dev/null 2>&1 & wait_for_pid created $!; return_value=$? # Make lock for RedHat / SuSE if test -w /var/lock/subsys then touch /var/lock/subsys/mysqlmanager fi exit $return_value elif test -x $bindir/mysqld_safe then # Give extra arguments to mysqld with the my.cnf file. This script # may be overwritten at next upgrade. pid_file=$server_pid_file $bindir/mysqld_safe --datadir=$datadir --pid-file=$server_pid_file $other_args >/dev/null 2>&1 & wait_for_pid created $!; return_value=$? # Make lock for RedHat / SuSE if test -w /var/lock/subsys then touch /var/lock/subsys/mysql fi exit $return_value else log_failure_msg "Couldn't find MySQL manager ($manager) or server ($bindir/mysqld_safe)" fi ;; 'stop') # Stop daemon. We use a signal here to avoid having to know the # root password. # The RedHat / SuSE lock directory to remove lock_dir=/var/lock/subsys/mysqlmanager # If the manager pid_file doesn't exist, try the server's if test ! -s "$pid_file" then pid_file=$server_pid_file lock_dir=/var/lock/subsys/mysql fi if test -s "$pid_file" then mysqlmanager_pid=`cat $pid_file` echo $echo_n "Shutting down MySQL" kill $mysqlmanager_pid # mysqlmanager should remove the pid_file when it exits, so wait for it. wait_for_pid removed "$mysqlmanager_pid"; return_value=$? # delete lock for RedHat / SuSE if test -f $lock_dir then rm -f $lock_dir fi exit $return_value else log_failure_msg "MySQL manager or server PID file could not be found!" fi ;; 'restart') # Stop the service and regardless of whether it was # running or not, start it again. if $0 stop $other_args; then $0 start $other_args else log_failure_msg "Failed to stop running server, so refusing to try to start." exit 1 fi ;; 'reload'|'force-reload') if test -s "$server_pid_file" ; then read mysqld_pid < $server_pid_file kill -HUP $mysqld_pid && log_success_msg "Reloading service MySQL" touch $server_pid_file else log_failure_msg "MySQL PID file could not be found!" exit 1 fi ;; 'status') # First, check to see if pid file exists if test -s "$server_pid_file" ; then read mysqld_pid < $server_pid_file if kill -0 $mysqld_pid 2>/dev/null ; then log_success_msg "MySQL running ($mysqld_pid)" exit 0 else log_failure_msg "MySQL is not running, but PID file exists" exit 1 fi else # Try to find appropriate mysqld process mysqld_pid=`pidof $sbindir/mysqld` if test -z $mysqld_pid ; then if test "$use_mysqld_safe" = "0" ; then lockfile=/var/lock/subsys/mysqlmanager else lockfile=/var/lock/subsys/mysql fi if test -f $lockfile ; then log_failure_msg "MySQL is not running, but lock exists" exit 2 fi log_failure_msg "MySQL is not running" exit 3 else log_failure_msg "MySQL is running but PID file could not be found" exit 4 fi fi ;; *) # usage echo "Usage: $0 {start|stop|restart|reload|force-reload|status} [ MySQL server options ]" exit 1 ;; esac exit 0 An unimportant aside: The previous users of the machine kept a messy home directory. Their home directory was /root. I've pasted a copy at http://www.pastebin.ca/2167496. My question: Why is there a /etc/init.d/mysql file on this Slackware machine? How could it have gotten there? P.S. This question is far from perfect. Please feel free to edit it.

    Read the article

  • virtual directory make file copy operation extremely slow on UNC Path (IIS 7.5 bug?)

    - by user144737
    When i create a website/virtual directory pointing to UNC path, its make our file copy extremely slow on the UNC path. 6 seconds for file copy (~13 M) on the UNC path without any virtual directory/website pointing to it. over 1 mins. for file copy (same files ~13M) on the same UNC path with virtual directory/website pointing to it. All file copy operation run on web server side. Our setting as below: Web server - Windows Server standard R2 2008 / IIS 7.5 File server - Windows Server standard 2003 I have tested this case on 3 servers (Windows Server standard R2 2008 / IIS 7.5) and got same result. I also tested this case on 2 windows 2003 / IIS 6, it won't slow down the file copy. Is it IIS 7.5 bug? any patch/hotfix to solve this case? Thank you. Gordon

    Read the article

  • Recover Data Like a Forensics Expert Using an Ubuntu Live CD

    - by Trevor Bekolay
    There are lots of utilities to recover deleted files, but what if you can’t boot up your computer, or the whole drive has been formatted? We’ll show you some tools that will dig deep and recover the most elusive deleted files, or even whole hard drive partitions. We’ve shown you simple ways to recover accidentally deleted files, even a simple method that can be done from an Ubuntu Live CD, but for hard disks that have been heavily corrupted, those methods aren’t going to cut it. In this article, we’ll examine four tools that can recover data from the most messed up hard drives, regardless of whether they were formatted for a Windows, Linux, or Mac computer, or even if the partition table is wiped out entirely. Note: These tools cannot recover data that has been overwritten on a hard disk. Whether a deleted file has been overwritten depends on many factors – the quicker you realize that you want to recover a file, the more likely you will be able to do so. Our setup To show these tools, we’ve set up a small 1 GB hard drive, with half of the space partitioned as ext2, a file system used in Linux, and half the space partitioned as FAT32, a file system used in older Windows systems. We stored ten random pictures on each hard drive. We then wiped the partition table from the hard drive by deleting the partitions in GParted. Is our data lost forever? Installing the tools All of the tools we’re going to use are in Ubuntu’s universe repository. To enable the repository, open Synaptic Package Manager by clicking on System in the top-left, then Administration > Synaptic Package Manager. Click on Settings > Repositories and add a check in the box labelled “Community-maintained Open Source software (universe)”. Click Close, and then in the main Synaptic Package Manager window, click the Reload button. Once the package list has reloaded, and the search index rebuilt, search for and mark for installation one or all of the following packages: testdisk, foremost, and scalpel. Testdisk includes TestDisk, which can recover lost partitions and repair boot sectors, and PhotoRec, which can recover many different types of files from tons of different file systems. Foremost, originally developed by the US Air Force Office of Special Investigations, recovers files based on their headers and other internal structures. Foremost operates on hard drives or drive image files generated by various tools. Finally, scalpel performs the same functions as foremost, but is focused on enhanced performance and lower memory usage. Scalpel may run better if you have an older machine with less RAM. Recover hard drive partitions If you can’t mount your hard drive, then its partition table might be corrupted. Before you start trying to recover your important files, it may be possible to recover one or more partitions on your drive, recovering all of your files with one step. Testdisk is the tool for the job. Start it by opening a terminal (Applications > Accessories > Terminal) and typing in: sudo testdisk If you’d like, you can create a log file, though it won’t affect how much data you recover. Once you make your choice, you’re greeted with a list of the storage media on your machine. You should be able to identify the hard drive you want to recover partitions from by its size and label. TestDisk asks you select the type of partition table to search for. In most cases (ext2/3, NTFS, FAT32, etc.) you should select Intel and press Enter. Highlight Analyse and press enter. In our case, our small hard drive has previously been formatted as NTFS. Amazingly, TestDisk finds this partition, though it is unable to recover it. It also finds the two partitions we just deleted. We are able to change their attributes, or add more partitions, but we’ll just recover them by pressing Enter. If TestDisk hasn’t found all of your partitions, you can try doing a deeper search by selecting that option with the left and right arrow keys. We only had these two partitions, so we’ll recover them by selecting Write and pressing Enter. Testdisk informs us that we will have to reboot. Note: If your Ubuntu Live CD is not persistent, then when you reboot you will have to reinstall any tools that you installed earlier. After restarting, both of our partitions are back to their original states, pictures and all. Recover files of certain types For the following examples, we deleted the 10 pictures from both partitions and then reformatted them. PhotoRec Of the three tools we’ll show, PhotoRec is the most user-friendly, despite being a console-based utility. To start recovering files, open a terminal (Applications > Accessories > Terminal) and type in: sudo photorec To begin, you are asked to select a storage device to search. You should be able to identify the right device by its size and label. Select the right device, and then hit Enter. PhotoRec asks you select the type of partition to search. In most cases (ext2/3, NTFS, FAT, etc.) you should select Intel and press Enter. You are given a list of the partitions on your selected hard drive. If you want to recover all of the files on a partition, then select Search and hit enter. However, this process can be very slow, and in our case we only want to search for pictures files, so instead we use the right arrow key to select File Opt and press Enter. PhotoRec can recover many different types of files, and deselecting each one would take a long time. Instead, we press “s” to clear all of the selections, and then find the appropriate file types – jpg, gif, and png – and select them by pressing the right arrow key. Once we’ve selected these three, we press “b” to save these selections. Press enter to return to the list of hard drive partitions. We want to search both of our partitions, so we highlight “No partition” and “Search” and then press Enter. PhotoRec prompts for a location to store the recovered files. If you have a different healthy hard drive, then we recommend storing the recovered files there. Since we’re not recovering very much, we’ll store it on the Ubuntu Live CD’s desktop. Note: Do not recover files to the hard drive you’re recovering from. PhotoRec is able to recover the 20 pictures from the partitions on our hard drive! A quick look in the recup_dir.1 directory that it creates confirms that PhotoRec has recovered all of our pictures, save for the file names. Foremost Foremost is a command-line program with no interactive interface like PhotoRec, but offers a number of command-line options to get as much data out of your had drive as possible. For a full list of options that can be tweaked via the command line, open up a terminal (Applications > Accessories > Terminal) and type in: foremost –h In our case, the command line options that we are going to use are: -t, a comma-separated list of types of files to search for. In our case, this is “jpeg,png,gif”. -v, enabling verbose-mode, giving us more information about what foremost is doing. -o, the output folder to store recovered files in. In our case, we created a directory called “foremost” on the desktop. -i, the input that will be searched for files. This can be a disk image in several different formats; however, we will use a hard disk, /dev/sda. Our foremost invocation is: sudo foremost –t jpeg,png,gif –o foremost –v –i /dev/sda Your invocation will differ depending on what you’re searching for and where you’re searching for it. Foremost is able to recover 17 of the 20 files stored on the hard drive. Looking at the files, we can confirm that these files were recovered relatively well, though we can see some errors in the thumbnail for 00622449.jpg. Part of this may be due to the ext2 filesystem. Foremost recommends using the –d command-line option for Linux file systems like ext2. We’ll run foremost again, adding the –d command-line option to our foremost invocation: sudo foremost –t jpeg,png,gif –d –o foremost –v –i /dev/sda This time, foremost is able to recover all 20 images! A final look at the pictures reveals that the pictures were recovered with no problems. Scalpel Scalpel is another powerful program that, like Foremost, is heavily configurable. Unlike Foremost, Scalpel requires you to edit a configuration file before attempting any data recovery. Any text editor will do, but we’ll use gedit to change the configuration file. In a terminal window (Applications > Accessories > Terminal), type in: sudo gedit /etc/scalpel/scalpel.conf scalpel.conf contains information about a number of different file types. Scroll through this file and uncomment lines that start with a file type that you want to recover (i.e. remove the “#” character at the start of those lines). Save the file and close it. Return to the terminal window. Scalpel also has a ton of command-line options that can help you search quickly and effectively; however, we’ll just define the input device (/dev/sda) and the output folder (a folder called “scalpel” that we created on the desktop). Our invocation is: sudo scalpel /dev/sda –o scalpel Scalpel is able to recover 18 of our 20 files. A quick look at the files scalpel recovered reveals that most of our files were recovered successfully, though there were some problems (e.g. 00000012.jpg). Conclusion In our quick toy example, TestDisk was able to recover two deleted partitions, and PhotoRec and Foremost were able to recover all 20 deleted images. Scalpel recovered most of the files, but it’s very likely that playing with the command-line options for scalpel would have enabled us to recover all 20 images. These tools are lifesavers when something goes wrong with your hard drive. If your data is on the hard drive somewhere, then one of these tools will track it down! Similar Articles Productive Geek Tips Recover Deleted Files on an NTFS Hard Drive from a Ubuntu Live CDUse an Ubuntu Live CD to Securely Wipe Your PC’s Hard DriveReset Your Ubuntu Password Easily from the Live CDBackup Your Windows Live Writer SettingsAdding extra Repositories on Ubuntu TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Awe inspiring, inter-galactic theme (Win 7) Case Study – How to Optimize Popular Wordpress Sites Restore Hidden Updates in Windows 7 & Vista Iceland an Insurance Job? Find Downloads and Add-ins for Outlook Recycle !

    Read the article

  • Thinking of Adopting the PRINCE2™ Project Management Methodology? Consider Using PeopleSoft Projects to Help

    - by Megan Boundey
    Ever wondered what the PRINCE2™ project management methodology is? Ever wondered if you could use PeopleSoft Projects (ESA) to manage your projects using PRINCE2™?  Published by the Office of Government Commerce in the UK, PRINCE2™ is a scalable, business case and product description-driven Project Management methodology based upon managing by exception. Project activities are organized around fulfilling and meeting the product description. Quality assurance, configuration control and risk management are all based upon ensuring that the product delivered accurately meets the product description. PRINCE2™ is built upon seven principles and seven themes, each underpinning the PRINCE2™project management processes. Important for today’s business environment, the focus throughout PRINCE2™ is on the Business Case, which describes the rationale and business justification for a project. The Business Case drives all the project management processes from initial project setup to successful finish. PRINCE2™, as a method and a certification, is adopted in many countries worldwide, including the UK, Western Europe and Australia. We’ve just released a new white paper, which provides you with an overview of the principles, themes and project management processes associated with PRINCE2™. It also shows how these map to the functionality available within PeopleSoft Projects (ESA). In the time it takes to drink a coffee, you can learn about PRINCE2™ and determine whether it might help you deliver better project results. We encourage you to take a look.

    Read the article

  • How To Change The Screen Resolution in C#

    - by SAMIR BHOGAYTA
    All programmers are facing common problem is how to change screen Resolution dynamically. In .Net 2005 it's very easy to change the screen resolution. Here We will explain you how can we get the Screen resolution and how we will change the resolution at dynamically and while unloading the page it will come as it was before. In dot net we can access the values of user's screen resolution through the Resolution class. It also affects all running (and minimized) programs. Page_Load Function Screen Srn = Screen.PrimaryScreen; tempHeight = Srn.Bounds.Width; tempWidth = Srn.Bounds.Height; Page.ClientScript.RegisterStartupScript (this.GetType(), "Error", "alert('" + "Your Current Resolution is = " + tempHeight + " * " + tempWidth + "');"); //if you want Automatically Change res.at page load. //please uncomment this code. if (tempHeight == 600)//if the system is 800*600 Res.then change to { FixHeight = 768; FixWidth = 1024; Resolution.CResolution ChangeRes = new Resolution.CResolution(FixHeight, FixWidth); } Change Resoultion in C# switch (cboRes.SelectedValue.ToString()) { case "800*600": FixHeight = 800; FixWidth = 600; Resolution.CResolution ChangeRes600 = new Resolution.CResolution(FixHeight, FixWidth); break; case "1024*768": FixHeight = 1024; FixWidth = 768; Resolution.CResolution ChangeRes768 = new Resolution.CResolution(FixHeight, FixWidth); break; case "1280*1024":How To Change The Screen Resolution in C# FixHeight = 1280; FixWidth = 1024; Resolution.CResolution ChangeRes1024 = new Resolution.CResolution(FixHeight, FixWidth); break; }

    Read the article

  • SRs @ Oracle: How do I License Thee?

    - by [email protected]
    With the release of the new Sun Ray product last week comes the advent of a different software licensing model. Where Sun had initially taken the approach of '1 desktop device = one license', we later changed things to be '1 concurrent connection to the server software = one license', and while there were ways to tell how many connections there were at a time, it wasn't the easiest thing to do.  And, when should you measure concurrency?  At your busiest time, of course... but when might that be?  9:00 Monday morning this week might yield a different result than 9:00 Monday morning last week.In the acquisition of this desktop virtualization product suite Oracle has changed things to be, in typical Oracle fashion, simpler.  There are now two choices for customers around licensing: Named User licenses and Per Device licenses.Here's how they work, and some examples:The Rules1) A Sun Ray device, and PC running the Desktop Access Client (DAC), are both considered unique devices.OR, 2) Any user running a session on either a Sun Ray or an DAC is still just one user.So, you have a choice of path to go down.Some Examples:Here are 6 use cases I can think of right now that will help you choose the Oracle server software licensing model that is right for your business:Case 1If I have 100 Sun Rays for 100 users, and 20 of them use DAC at home that is 100 user licenses.If I have 100 Sun Rays for 100 users, and 20 of them use DAC at home that is 120 device licenses.Two cases using the same metrics - different licensing models and therefore different results.Case 2If I have 100 Sun Rays for 200 users, and 20 of them use DAC at home that is 200 user licenses.If I have 100 Sun Rays for 200 users, and 20 of them use DAC at home that is 120 device licenses.Same metrics - very different results.Case 3If I have 100 Sun Rays for 50 users, and 20 of them use DAC at home that is 50 user licenses.If I have 100 Sun Rays for 50 users, and 20 of them use DAC at home that is 120 device licenses.Same metrics - but again - very different results.Based on the way your business operates you should be able to see which of the two licensing models is most advantageous to you.Got questions?  I'll try to help.(Thanks to Brad Lackey for the clarifications!)

    Read the article

  • Rackmount temperature/humidity control

    - by Evan Plaice
    This may seem like a strange question because it involves a non-traditional approach. What I'm looking for is a standard rackmount cooling/humidity control module. The idea is to build a portable server rack (in a case) that can be deployed to the field but limit the cooling/temperature control requirements to just the case that the server gear is contained in. I understand that the chiller may warm it's surrounding environment so, as an additional approach, it will be possible to have a separate case for the chiller alone. Do these exist? What are they called? Where can I find one?

    Read the article

  • Professional Scrum Developer (.NET) Training in London

    - by Martin Hinshelwood
    On the 26th - 30th July in Microsoft’s offices in London Adam Cogan from SSW will be presenting the first Professional Scrum Developer course in the UK. I will be teaching this course along side Adam and it is a fantastic experience. You are split into teams and go head-to-head to deliver units of potentially shippable work in four two hour sprints. The Professional Scrum Developer course is the only course endorsed by both Microsoft and Ken Schwaber and they have worked together very effectively in brining this course to fruition. This course is the brain child of Richard Hundhausen, a Microsoft Regional Director, and both Adam and I attending the Trainer Prep in Sydney when he was there earlier this year. He is a fantastic trainer and no matter where you do this course you can be safe in the knowledge that he has trained and vetted all of the teachers. A tools version of Ken if you will Find a course and register Download this syllabus Download the Scrum Guide What is the Professional Scrum Developer course all about? Professional Scrum Developer course is a unique and intensive five-day experience for software developers. The course guides teams on how to turn product requirements into potentially shippable increments of software using the Scrum framework, Visual Studio 2010, and modern software engineering practices. Attendees will work in self-organizing, self-managing teams using a common instance of Team Foundation Server 2010. Who should attend this course? This course is suitable for any member of a software development team – architect, programmer, database developer, tester, etc. Entire teams are encouraged to attend and experience the course together, but individuals are welcome too. Attendees will self-organize to form cross-functional Scrum teams. These teams require an aggregate of skills specific to the selected case study. Please see the last page of this document for specific details. Product Owners, ScrumMasters, and other stakeholders are welcome too, but keep in mind that everyone who attends will be expected to commit to work and pull their weight on a Scrum team. What should you know by the end of the course? Scrum will be experienced through a combination of lecture, demonstration, discussion, and hands-on exercises. Attendees will learn how to do Scrum correctly while being coached and critiqued by the instructor, in the following topic areas: Form effective teams Explore and understand legacy “Brownfield” architecture Define quality attributes, acceptance criteria, and “done” Create automated builds How to handle software hotfixes Verify that bugs are identified and eliminated Plan releases and sprints Estimate product backlog items Create and manage a sprint backlog Hold an effective sprint review Improve your process by using retrospectives Use emergent architecture to avoid technical debt Use Test Driven Development as a design tool Setup and leverage continuous integration Use Test Impact Analysis to decrease testing times Manage SQL Server development in an Agile way Use .NET and T-SQL refactoring effectively Build, deploy, and test SQL Server databases Create and manage test plans and cases Create, run, record, and play back manual tests Setup a branching strategy and branch code Write more maintainable code Identify and eliminate people and process dysfunctions Inspect and improve your team’s software development process What does the week look like? This course is a mix of lecture, demonstration, group discussion, simulation, and hands-on software development. The bulk of the course will be spent working as a team on a case study application delivering increments of new functionality in mini-sprints. Here is the week at a glance: Monday morning and most of the day Friday will be spent with the computers powered off, so you can focus on sharpening your game of Scrum and avoiding the common pitfalls when implementing it. The Sprints Timeboxing is a critical concept in Scrum as well as in this course. We expect each team and student to understand and obey all of the timeboxes. The timebox duration will always be clearly displayed during each activity. Expect the instructor to enforce it. Each of the ½ day sprints will roughly follow this schedule: Component Description Minutes Instruction Presentation and demonstration of new and relevant tools & practices 60 Sprint planning meeting Product owner presents backlog; each team commits to delivering functionality 10 Sprint planning meeting Each team determines how to build the functionality 10 The Sprint The team self-organizes and self-manages to complete their tasks 120 Sprint Review meeting Each team will present their increment of functionality to the other teams = 30 Sprint Retrospective A group retrospective meeting will be held to inspect and adapt 10 Each team is expected to self-organize and manage their own work during the sprint. Pairing is highly encouraged. The instructor/product owner will be available if there are questions or impediments, but will be hands-off by default. You should be prepared to communicate and work with your team members in order to achieve your sprint goal. If you have development-related questions or get stuck, your partner or team should be your first level of support. Module 1: INTRODUCTION This module provides a chance for the attendees to get to know the instructors as well as each other. The Professional Scrum Developer program, as well as the day by day agenda, will be explained. Finally, the Scrum team will be selected and assembled so that the forming, storming, norming, and performing can begin. Trainer and student introductions Professional Scrum Developer program Agenda Logistics Team formation Retrospective Module 2: SCRUMDAMENTALS This module provides a level-setting understanding of the Scrum framework including the roles, timeboxes, and artifacts. The team will then experience Scrum firsthand by simulating a multi-day sprint of product development, including planning, review, and retrospective meetings. Scrum overview Scrum roles Scrum timeboxes (ceremonies) Scrum artifacts Simulation Retrospective It’s required that you read Ken Schwaber’s Scrum Guide in preparation for this module and course. MODULE 3: IMPLEMENTING SCRUM IN VISUAL STUDIO 2010 This module demonstrates how to implement Scrum in Visual Studio 2010 using a Scrum process template*. The team will learn the mapping between the Scrum concepts and how they are implemented in the tool. After connecting to the shared Team Foundation Server, the team members will then return to the simulation – this time using Visual Studio to manage their product development. Mapping Scrum to Visual Studio 2010 User Story work items Task work items Bug work items Demonstration Simulation Retrospective Module 4: THE CASE STUDY In this module the team is introduced to their problem domain for the week. A kickoff meeting by the Product Owner (the instructor) will set the stage for the why and what that will take during the upcoming sprints. The team will then define the quality attributes of the project and their definition of “done.” The legacy application code will be downloaded, built, and explored, so that any bugs can be discovered and reported. Introduction to the case study Download the source code, build, and explore the application Define the quality attributes for the project Define “done” How to file effective bugs in Visual Studio 2010 Retrospective Module 5: HOTFIX This module drops the team directly into a Brownfield (legacy) experience by forcing them to analyze the existing application’s architecture and code in order to locate and fix the Product Owner’s high-priority bug(s). The team will learn best practices around finding, testing, fixing, validating, and closing a bug. How to use Architecture Explorer to visualize and explore Create a unit test to validate the existence of a bug Find and fix the bug Validate and close the bug Retrospective Module 6: PLANNING This short module introduces the team to release and sprint planning within Visual Studio 2010. The team will define and capture their goals as well as other important planning information. Release vs. Sprint planning Release planning and the Product Backlog Product Backlog prioritization Acceptance criteria and tests Sprint planning and the Sprint Backlog Creating and linking Sprint tasks Retrospective At this point the team will have the knowledge of Scrum, Visual Studio 2010, and the case study application to begin developing increments of potentially shippable functionality that meet their definition of done. Module 7: EMERGENT ARCHITECTURE This module introduces the architectural practices and tools a team can use to develop a valid design on which to develop new functionality. The teams will learn how Scrum supports good architecture and design practices. After the discussion, the teams will be presented with the product owner’s prioritized backlog so that they may select and commit to the functionality they can deliver in this sprint. Architecture and Scrum Emergent architecture Principles, patterns, and practices Visual Studio 2010 modeling tools UML and layer diagrams SPRINT 1 Retrospective Module 8: TEST DRIVEN DEVELOPMENT This module introduces Test Driven Development as a design tool and how to implement it using Visual Studio 2010. To maximize productivity and quality, a Scrum team should setup Continuous Integration to regularly build every team member’s code changes and run regression tests. Refactoring will also be defined and demonstrated in combination with Visual Studio’s Test Impact Analysis to efficiently re-run just those tests which were impacted by refactoring. Continuous integration Team Foundation Build Test Driven Development (TDD) Refactoring Test Impact Analysis SPRINT 2 Retrospective Module 9: AGILE DATABASE DEVELOPMENT This module lets the SQL Server database developers in on a little secret – they can be agile too. By using the database projects in Visual Studio 2010, the database developers can join the rest of the team. The students will see how to apply Agile database techniques within Visual Studio to support the SQL Server 2005/2008/2008R2 development lifecycle. Agile database development Visual Studio database projects Importing schema and scripts Building and deploying Generating data Unit testing SPRINT 3 Retrospective Module 10: SHIP IT Teams need to know that just because they like the functionality doesn’t mean the Product Owner will. This module revisits acceptance criteria as it pertains to acceptance testing. By refining acceptance criteria into manual test steps, team members can execute the tests, recording the results and reporting bugs in a number of ways. Manual tests will be defined and executed using the Microsoft Test Manager tool. As the Sprint completes and an increment of functionality is delivered, the team will also learn why and when they should create a branch of the codeline. Acceptance criteria Testing in Visual Studio 2010 Microsoft Test Manager Writing and running manual tests Branching SPRINT 4 Retrospective Module 11: OVERCOMING DYSFUNCTION This module introduces the many types of people, process, and tool dysfunctions that teams face in the real world. Many dysfunctions and scenarios will be identified, along with ideas and discussion for how a team might mitigate them. This module will enable you and your team to move toward independence and improve your game of Scrum when you depart class. Scrum-butts and flaccid Scrum Best practices working as a team Team challenges ScrumMaster challenges Product Owner challenges Stakeholder challenges Course Retrospective What will be expected of you and you team? This is a unique course in that it’s technically-focused, team-based, and employs timeboxes. It demands that the members of the teams self-organize and self-manage their own work to collaboratively develop increments of software. All attendees must commit to: Pay attention to all lectures and demonstrations Participate in team and group discussions Work collaboratively with other team members Obey the timebox for each activity Commit to work and do your best to deliver All teams should have these skills: Understanding of Scrum Familiarity with Visual Studio 201 C#, .NET 4.0 & ASP.NET 4.0 experience*  SQL Server 2008 development experience Software testing experience * Check with the instructor ahead of time for the exact technologies Self-organising teams Another unique attribute of this course is that it’s a technical training class being delivered to teams of developers, not pairs, and not individuals. Ideally, your actual software development team will attend the training to ensure that all necessary skills are covered. However, if you wish to attend an open enrolment course alone or with just a couple of colleagues, realize that you may be placed on a team with other attendees. The instructor will do his or her best to ensure that each team is cross-functional to tackle the case study, but there are no guarantees. You may be required to try a new role, learn a new skill, or pair with somebody unfamiliar to you. This is just good Scrum! Who should NOT take this course? Because of the nature of this course, as explained above, certain types of people should probably not attend this course: Students requiring command and control style instruction – there are no prescriptive/step-by-step (think traditional Microsoft Learning) labs in this course Students who are unwilling to work within a timebox Students who are unwilling to work collaboratively on a team Students who don’t have any skill in any of the software development disciplines Students who are unable to commit fully to their team – not only will this diminish the student’s learning experience, but it will also impact their team’s learning experience Find a course and register Download this syllabus Download the Scrum Guide Technorati Tags: Scrum,SSW,Pro Scrum Dev

    Read the article

  • VLOOKUP in Excel, part 2: Using VLOOKUP without a database

    - by Mark Virtue
    In a recent article, we introduced the Excel function called VLOOKUP and explained how it could be used to retrieve information from a database into a cell in a local worksheet.  In that article we mentioned that there were two uses for VLOOKUP, and only one of them dealt with querying databases.  In this article, the second and final in the VLOOKUP series, we examine this other, lesser known use for the VLOOKUP function. If you haven’t already done so, please read the first VLOOKUP article – this article will assume that many of the concepts explained in that article are already known to the reader. When working with databases, VLOOKUP is passed a “unique identifier” that serves to identify which data record we wish to find in the database (e.g. a product code or customer ID).  This unique identifier must exist in the database, otherwise VLOOKUP returns us an error.  In this article, we will examine a way of using VLOOKUP where the identifier doesn’t need to exist in the database at all.  It’s almost as if VLOOKUP can adopt a “near enough is good enough” approach to returning the data we’re looking for.  In certain circumstances, this is exactly what we need. We will illustrate this article with a real-world example – that of calculating the commissions that are generated on a set of sales figures.  We will start with a very simple scenario, and then progressively make it more complex, until the only rational solution to the problem is to use VLOOKUP.  The initial scenario in our fictitious company works like this:  If a salesperson creates more than $30,000 worth of sales in a given year, the commission they earn on those sales is 30%.  Otherwise their commission is only 20%.  So far this is a pretty simple worksheet: To use this worksheet, the salesperson enters their sales figures in cell B1, and the formula in cell B2 calculates the correct commission rate they are entitled to receive, which is used in cell B3 to calculate the total commission that the salesperson is owed (which is a simple multiplication of B1 and B2). The cell B2 contains the only interesting part of this worksheet – the formula for deciding which commission rate to use: the one below the threshold of $30,000, or the one above the threshold.  This formula makes use of the Excel function called IF.  For those readers that are not familiar with IF, it works like this: IF(condition,value if true,value if false) Where the condition is an expression that evaluates to either true or false.  In the example above, the condition is the expression B1<B5, which can be read as “Is B1 less than B5?”, or, put another way, “Are the total sales less than the threshold”.  If the answer to this question is “yes” (true), then we use the value if true parameter of the function, namely B6 in this case – the commission rate if the sales total was below the threshold.  If the answer to the question is “no” (false), then we use the value if false parameter of the function, namely B7 in this case – the commission rate if the sales total was above the threshold. As you can see, using a sales total of $20,000 gives us a commission rate of 20% in cell B2.  If we enter a value of $40,000, we get a different commission rate: So our spreadsheet is working. Let’s make it more complex.  Let’s introduce a second threshold:  If the salesperson earns more than $40,000, then their commission rate increases to 40%: Easy enough to understand in the real world, but in cell B2 our formula is getting more complex.  If you look closely at the formula, you’ll see that the third parameter of the original IF function (the value if false) is now an entire IF function in its own right.  This is called a nested function (a function within a function).  It’s perfectly valid in Excel (it even works!), but it’s harder to read and understand. We’re not going to go into the nuts and bolts of how and why this works, nor will we examine the nuances of nested functions.  This is a tutorial on VLOOKUP, not on Excel in general. Anyway, it gets worse!  What about when we decide that if they earn more than $50,000 then they’re entitled to 50% commission, and if they earn more than $60,000 then they’re entitled to 60% commission? Now the formula in cell B2, while correct, has become virtually unreadable.  No-one should have to write formulae where the functions are nested four levels deep!  Surely there must be a simpler way? There certainly is.  VLOOKUP to the rescue! Let’s redesign the worksheet a bit.  We’ll keep all the same figures, but organize it in a new way, a more tabular way: Take a moment and verify for yourself that the new Rate Table works exactly the same as the series of thresholds above. Conceptually, what we’re about to do is use VLOOKUP to look up the salesperson’s sales total (from B1) in the rate table and return to us the corresponding commission rate.  Note that the salesperson may have indeed created sales that are not one of the five values in the rate table ($0, $30,000, $40,000, $50,000 or $60,000).  They may have created sales of $34,988.  It’s important to note that $34,988 does not appear in the rate table.  Let’s see if VLOOKUP can solve our problem anyway… We select cell B2 (the location we want to put our formula), and then insert the VLOOKUP function from the Formulas tab: The Function Arguments box for VLOOKUP appears.  We fill in the arguments (parameters) one by one, starting with the Lookup_value, which is, in this case, the sales total from cell B1.  We place the cursor in the Lookup_value field and then click once on cell B1: Next we need to specify to VLOOKUP what table to lookup this data in.  In this example, it’s the rate table, of course.  We place the cursor in the Table_array field, and then highlight the entire rate table – excluding the headings: Next we must specify which column in the table contains the information we want our formula to return to us.  In this case we want the commission rate, which is found in the second column in the table, so we therefore enter a 2 into the Col_index_num field: Finally we enter a value in the Range_lookup field. Important:  It is the use of this field that differentiates the two ways of using VLOOKUP.  To use VLOOKUP with a database, this final parameter, Range_lookup, must always be set to FALSE, but with this other use of VLOOKUP, we must either leave it blank or enter a value of TRUE.  When using VLOOKUP, it is vital that you make the correct choice for this final parameter. To be explicit, we will enter a value of true in the Range_lookup field.  It would also be fine to leave it blank, as this is the default value: We have completed all the parameters.  We now click the OK button, and Excel builds our VLOOKUP formula for us: If we experiment with a few different sales total amounts, we can satisfy ourselves that the formula is working. Conclusion In the “database” version of VLOOKUP, where the Range_lookup parameter is FALSE, the value passed in the first parameter (Lookup_value) must be present in the database.  In other words, we’re looking for an exact match. But in this other use of VLOOKUP, we are not necessarily looking for an exact match.  In this case, “near enough is good enough”.  But what do we mean by “near enough”?  Let’s use an example:  When searching for a commission rate on a sales total of $34,988, our VLOOKUP formula will return us a value of 30%, which is the correct answer.  Why did it choose the row in the table containing 30% ?  What, in fact, does “near enough” mean in this case?  Let’s be precise: When Range_lookup is set to TRUE (or omitted), VLOOKUP will look in column 1 and match the highest value that is not greater than the Lookup_value parameter. It’s also important to note that for this system to work, the table must be sorted in ascending order on column 1! If you would like to practice with VLOOKUP, the sample file illustrated in this article can be downloaded from here. Similar Articles Productive Geek Tips Using VLOOKUP in ExcelImport Microsoft Access Data Into ExcelImport an Access Database into ExcelCopy a Group of Cells in Excel 2007 to the Clipboard as an ImageShare Access Data with Excel in Office 2010 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Quickly Schedule Meetings With NeedtoMeet Share Flickr Photos On Facebook Automatically Are You Blocked On Gtalk? Find out Discover Latest Android Apps On AppBrain The Ultimate Guide For YouTube Lovers Will it Blend? iPad Edition

    Read the article

  • 4th International SOA Symposium + 3rd International Cloud Symposium by Thomas Erl - call for presentations

    - by Jürgen Kress
    At the last SOA & Cloud Symposium by Thomas Erl the SOA Partner Community had a great present. The next conference takes place April 2011 in Brazil, make sure you submit your papers. The International SOA and Cloud Symposium brings together lessons learned and emerging topics from SOA and Cloud projects, practitioners and experts. The two-day conference agenda will be organized into the following primary tracks: SOA Architecture & Design SOA & BPM Real World SOA Case Studies SOA & Cloud Security Real World Cloud Computing Case Studies REST & Service-Orientation BPM, BPMN & Service-Orientation Business of SOA SOA & Cloud: Infrastructure & Architecture Business of Cloud Computing Presentation Submissions The SOA and Cloud Symposium 2010 program committees invite submissions on all topics related to SOA and Cloud, including but not limited to those listed in the preceding track descriptions. While contributions from consultants and vendors are appreciated, product demonstrations or vendor showcases will not be accepted. All contributions must be accompanied with a biography that describes the SOA or Cloud Computing related experience of the presenter(s). Presentation proposals should be submitted by filling out the speaker form and sending the completed form to [email protected]. All submissions must be received no later than January 31, 2010. To download the speaker form, please click here. Specially we are looking for Oracle SOA Suite and BPM Suite Case Studies! For additional call for papers please visit our SOA Community Wiki.   For more information on SOA Specialization and the SOA Partner Community please feel free to register at www.oracle.com/goto/emea/soa (OPN account required) Blog Twitter LinkedIn Mix Forum Wiki Website Technorati Tags: SOA Symposium,Cloud Symposium,Thomas Erl,SOA,SOA Suite,Oracle,Call for papers,OPN,BPM,Jürgen Kress

    Read the article

  • Should MVVM ViewModel inject an HTML template for default view?

    - by explunit
    I'm working on web application design that includes Knockout.js and have an overall MVVM question: Does it make sense for the ViewModel to automatically inject a default HTML template (pulled from separate file)? More detail: suppose I have a site like this... header... widget 1 widget 2 widget 3 footer ...and widgets 1/2/3 are going to be Knockout.js ViewModels determined at runtime from an overall list of available widgets, each with associated HTML template file. I understand that in MVVM you want the view (HTML template in this case) to be separate from the ViewModel (Javascript file in this case) so that people can edit it separately and possibly provide multiple templates for different "skins". However, it seems like it would also make sense for the ViewModel to point to a default html template that gets automatically used unless the controlling code provides a different one. Am I looking at this correctly? As an example, see this answer on StackOverflow where he recommends injecting the HTML and then the ViewModel. Seems like a one-liner would make more sense in that case, with the possibility of overriding a default template value.

    Read the article

  • What is the best position for power unit?

    - by guest86
    I would like to buy new computer case. Last time I bought a computer was in 2008 and many things have changed up to day. Many new computer cases have power unit placed down, on bottom. I'm thinking about buying some of those cases, but i'm not sure about something - if power unit is placed on the bottom it can't take away hot air from the case and pump it out right? All my PC parts are silent - CPU (E8200, placed below 12cm Nochtua fan of power unit) has heat-pipe cooler with Nochtua fan spinning at only 800rpms, GPU has cooler powered by 7V instead 12 and that's why i don't want to HAVE TO place another fan to pump out hot air instead of PU placed on top. That might make some noise. So i ask someone more experienced: if i buy some computer case with PU placed down, do i HAVE TO place some fan to pump out hot air?

    Read the article

< Previous Page | 60 61 62 63 64 65 66 67 68 69 70 71  | Next Page >