  • Can VMWare Server 2.0 be useful in Production for easing backups?

    - by Keith Sirmons
    Howdy, Let's run this idea by the group here. I am thinking about using VMWare Server in production to host a 2008 Domain Controller with DHCP and DNS, a 2008 member server with WSUS, some virus software, and other "management" utilities a second 2008 member server with SQL, IIS, and File Shares for a medium business of 50-100 desktops. The reason I am leaning toward Server vs ESXi is for backup purposes. Using ESXi, if I want to backup the VM's, I would need a second server in the office with enough storage availability to hold a copy of the vmdks. I am wondering if putting this virtual environment on top of a basic 2008 server install will allow for easier backups to both tape and/or to offsite storage using JungleDisk. Can a snapshot be triggered easily via a scheduled job? I know this doesn't necessarily handle file level restores, but I want to make sure in a DR situation, we can restore production servers quickly. Does this concept hold water? Would a very minimum install of the 2008 Host remove too many resources from the actual production machines? This would be a new Dell 410 server with 12 GB ram and (6) 600 GB 15K in a RAID 6, Dual Intel Xeon 2.26GHz procs.

    Read the article

  • Internal disk not correctly recognised by Windows 7

    - by david
    i'm having problems configuring a disk in a brand new, clean windows-7 install. here are some system specifics- . disk- western digital velociraptor wd6000hlhx . mobo- gigabyte z77x-ud3h . bios sata-mode set to ahci [not raid], w/disk connected to sata0 [6gb/s hi-speed sata]. . windows 7 enterprise sp1 x64 the disk is recognized by bios and correctly identified [name & size ok]. the disk is also recognized by windows on a h/w level, but it won't show up in the explorer. windows reports the device is working correctly. windows disk manager shows the drive, but says it's uninitialized and has no partitions [which is incorrect]. if i try to initialize the drive, windows throws an error saying that it "cannot find the file specified". [which file???] before connecting the drive to the new machine, i partitioned and formatted the disk under windows xp sp2, giving it 2 partitions [mbr, not gpt] and copying over a boatload of data. obviously none of this appears under windows 7. removing the disk from the new machine and replacing it back in the windows xp machine shows the disk and all data are intact and functional. i'd like to have windows 7 recognize the disk w/o having to lose the data and start over. is this possible? if so, how would i do that? I checked this post, but even though the problem seems identical, the information didn't help. any help appreciated. thanks!

    Read the article

  • Windows 7 install detects SSD but doesn't list it to install to

    - by Mohamed Meligy
    I'm having quite a weird problem when trying to install Windows 7 SP1 on a new Corsair Force Series 3 SSD to replace a failing HDD in my wife's laptop. When I boot to Windows install, it shows that I have no disks to install to, and tells me to find it a driver to any custom disks I may have. When I go to repair option on the first install window, and then open command prompt Window, I can see the disk using diskpart, and can partition it and format partitions, and then later access them from command prompt and copy files to them. After creating partitions, clicking the "browse" button in Windows install screen that shows no disks available to install Windows to, does show the partitions created by diskpart! So, it does detect the disk and partitions, but refuses to list them as options to install to. People on the Interwebs seem to suggest that just running diskpart "clean" solved the issue for most people, just creating an "active" "primary" partition is al most tutorials suggest. Both got me only as far as described above. The BIOS doesn't have RAID option, changing between "ATA" and "AHCI" (the only available options) didn't make any difference. Might be worth mentioning that this is on a laptop that has Sata III controller for main drive (which I connected the Sata3 SSD to), and Sata II for DVD (which I used for Windows install media). That's what googling brings at least (DELL XPS 15 L502). Any ideas? . Update: The SSD is 460 GB. I tried setting it all as one partition and creating 70-90 GB partition as well (NTFS). More importantly, Windows doesn't list the partition as one it cannot install to (which it does with disks in general when they are small for example). What happens here is different. It doesn't list anything at all. It shows empty list of drives.

    Read the article

  • Openfiler iSCSI performance

    - by Justin
    Hoping someone can point me in the right direction with some iSCSI performance issues I'm having. I'm running Openfiler 2.99 on an older ProLiant DL360 G5. Dual Xeon processor, 6GB ECC RAM, Intel Gigabit Server NIC, SAS controller with and 3 10K SAS drives in a RAID 5. When I run a simple write test from the box directly the performance is very good: [root@localhost ~]# dd if=/dev/zero of=tmpfile bs=1M count=1000 1000+0 records in 1000+0 records out 1048576000 bytes (1.0 GB) copied, 4.64468 s, 226 MB/s So I created a LUN, attached it to another box I have running ESXi 5.1 (Core i7 2600k, 16GB RAM, Intel Gigabit Server NIC) and created a new datastore. Once I created the datastore I was able to create and start a VM running CentOS with 2GB of RAM and 16GB of disk space. The OS installed fine and I'm able to use it but when I ran the same test inside the VM I get dramatically different results: [root@localhost ~]# dd if=/dev/zero of=tmpfile bs=1M count=1000 1000+0 records in 1000+0 records out 1048576000 bytes (1.0 GB) copied, 26.8786 s, 39.0 MB/s [root@localhost ~]# Both servers have brand new Intel Server NIC's and I have Jumbo Frames enabled on the switch, the openfiler box as well as the VMKernel adapter on the ESXi box. I can confirm this is set up properly by using the vmkping command from the ESXi host: ~ # vmkping 10.0.0.1 -s 9000 PING 10.0.0.1 (10.0.0.1): 9000 data bytes 9008 bytes from 10.0.0.1: icmp_seq=0 ttl=64 time=0.533 ms 9008 bytes from 10.0.0.1: icmp_seq=1 ttl=64 time=0.736 ms 9008 bytes from 10.0.0.1: icmp_seq=2 ttl=64 time=0.570 ms The only thing I haven't tried as far as networking goes is bonding two interfaces together. I'm open to trying that down the road but for now I am trying to keep things simple. I know this is a pretty modest setup and I'm not expecting top notch performance but I would like to see 90-100MB/s. Any ideas?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here. EDIT: I found another person who has the exact same problem as me: http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14451763

    Read the article

  • Will this increase my Virtual private Server failing rate ?

    - by Spencer Lim
    Will this increase my Virtual private Server failing rate if i :- install Microsoft Window Server 2008 Enterprise install SQL server enterprise 2008 install IIS 7.5 install ASP.Net Mvc 2 install Microsoft Exchange << should live inside MWS2008 ? or standalone without OS? install Team foundation server << should live inside MWS2008 ? or standalone without OS? on one mini VPS with specification of DELL Poweredge R710 shared plan DDR3 ECC RAMs 16GB and -- 1GB for this VPS using DELL PERC 6i raid controller (this thing alone about 1.5k-2k) and the SAS HDD (15K RPM) (146GB) -- 33GB to this VPS each hdd is freaking fast over 300MB read / write possible with proper tuning the motherboard is a DELL and it has twin redundant PSU (870watt 85%eff) its running on Intel Xeon 5502 (Quad Core) x2 so about 8 physical proc (fairly share) is there any ruler to measure for this about one VPS can only install what what what service ? because of my resource is limited =.@ may i know if it is install in this way,maybe it seem like defeat the way of "VPS"... what will happen ? or any guideline on this issue (fully configuring the window server 2008 R2) ? Thx for reply

    Read the article

  • Server Performance

    - by sb12
    I know very little about performance tuning of servers etc... so i thought i'd put this up here as i start some research on it, just to get some direction. I am in the process of migrating from my old server to a new one - both are 64 bit machines. One is a few years old, the other brand new (PowerEdge R410). The old server spec is: 2 cpus, 3.4GHz Pentiums, 8G of RAM, Fedora 11 currently installed The new server spec is: 16 cpus, 3.2 GHz Xeon, 16G of RAM, CentOS 6.2 installed. Also RAID10 is on the new server - no RAID on the old one. Both servers currently have the same database (MySQL) with the same data migrated. I wrote a Perl script that simply steps through each row of a table in the database (about 18000 rows) and updates a value in that row. Every row in the table is updated. Out of curiosity i ran this perl script on both machines, just to see how the new server would perform vs. the old one, and it produced interesting results: The old server was twice as fast as the new one to complete. Looking at the database, both are configured exactly the same (the new one being a dump of the old one...)... Anyone any ideas why this would be given the hardware gap between both? As i said i'm about to start some digging, but thought i'd put this up here to maybe get some good direction.... Many thanks in advance..

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article

  • Expected IOPS for log writing on PS6000X SAN?

    - by dssz
    Customer is experiencing poor Sybase ASE 15 performance on a PS6000X SAN with 16 X 450GB 10K in RAID-50. The server is a Dell R710 running 2003 server R2 64bit in ESX 4.0.0,256968 I've used sqlio to benchmark the sequential write performance of 4KB blocks on the drive. sqlio -kW -t1 -s600 -dE -o1 -fsequential -b4 -BH -LS sqliotestfile.dat Result is 1900 IOPS. However, when Sybase is running a sustained workload of small inserts SAN HQ shows a consistent 590 IOPS (and 100% 4K write activity). It also shows that the write latency increases to 1.2ms from <1ms. Monitoring and tests in Sybase demonstrate the performance problem is IO related and in particular there is a lot of wait time writing to the log. The SAN indicates that write caching is enabled. What IOPS should the SAN be capable of for 4k sequential write activity? Also, with write caching enabled, shouldn't the controller be batching up the 4K writes into something more efficient? Also, any tips on Sybase on ESX would be appreciated.

    Read the article

  • How does one change the UUID of a Volume on Mac OS X 10.6?

    - by Emmel
    Does anyone know how to change the UUID of a Volume? The background for this question is that I have a duplicate UUID issue: I have /Volumes/OldMacHD with a UUID of XYZ. I have /Volumes/Mirror1 with a UUID of XYZ (same UUID! I bet that's because OldMacHD USED to be part of this mirror). I got these UUIDs via 'diskutil info /dev/thatdisknumber | grep UUID'. I'd like to change the UUID of 'Mirror1'. I discovered by chance the 'hfs.util' utility, since these are HFS volumes after all. The man page for hfs.util says that if you issue the -s flag, this changes the UUID. However, if you type hfs.util all by itself, it doesn't show you the -s option at all, just every option besides that! Grr. I tried it anyway: sudo /System/Library/Filesystems/hfs.fs/hfs.util -s /dev/disk4 (the raid volume). Nothing happens. No error message, no success message. UUID exactly the same. I tried it while the volume was unmounted. Any ideas?

    Read the article

  • Dell PE2950 - slow IO rates for writing and reading locally

    - by OrenM
    I'm having a serious issue with dell server PE2950. The server has really slow IO rates, so slow that I'm not able to use it anymore I tried few things to solve this: changing disks to new disks (configured them as raid1) changing perc card + perc cables reinstalling the OS of course, had to cause of changing of disks, centos 5.5 x64bit firmware update to everything virtual disks policy: No Read Ahead,Write Back, disk cache policy disabled. openmanage doesn't alert about anything, also i ran dell's diag tests, everything passed, also dell didn't see anything in deset log. dell offered to reseat everything, including the cpu, we did that as well, still io rates are slow I have several PE2950 servers, and I never had such a thing with any of those. All have similar or exact hardware as this one, all configured the same, with the same os centos 5.5 x64, same disks, same raid, same policy. Just for comparison: the problematic PE2950 server: [root@bad ~]# time sh -c "dd if=/dev/zero of=/tmp/ddfile bs=8k count=200000 && sync" 200000+0 records in 200000+0 records out 1638400000 bytes (1.6 GB) copied, 27.7946 seconds, 58.9 MB/s real 0m33.968s user 0m0.531s sys 0m26.000s good PE2950 server (with the exact same hardware): [root@good ~]# time sh -c "dd if=/dev/zero of=/tmp/ddfile bs=8k count=200000 && sync" 200000+0 records in 200000+0 records out 1638400000 bytes (1.6 GB) copied, 3.19999 seconds, 512 MB/s real 0m7.694s user 0m0.053s sys 0m4.057s Hopefully you will have an idea what can cause the problem.

    Read the article

  • How do I resolve BSOD: PAGE_FAULT_IN_NONPAGED_AREA?

    - by Burnzy
    I have been trouble shooting this for a few days and cannot fix this anyhow. Computer specifications Mobo: ASUS Sabertooth X58 LGA 1366 Intel X58 SATA 6Gb/s USB 3.0 ATX Intel Motherboard CPU: Intel(R) Core(TM) i7 CPU 920 (Bloomfield) @ 2.67 ( no OC ) RAM: 6144MB RAM GPU: 2x NVIDIA GeForce GTS 250 1Go in SLI (sli is not enabled anyway at the moment anyway) Drives: OCZ RevoDrive OCZSSDPX-1RVD0120 PCI-E x4 120GB PCI Express MLC Internal SSD [RAID-0]. (I know this could potentilly cause trouble but I had the BSOD before using this drive) Seagate Barracuda 7200.11 ST31500341AS 1.5TB 7200 RPM 32MB Cache SATA 3.0Gb/s 3.5" Internal Hard Drive - Bare Drive Click here for a log of a crash I just had. Click here for a log of a crash I had 30 minutes later, note that it's another driver. Some info Occurence: It seems pretty random so far, haven't noticed any kind of pattern I tried: Windows memory diagnostic (went smoothly at 1066mhz) As I said, it was still happening on my HDD, so when I bought the revodrive I install a new OS on there and still got the error, I believed it happened and I had no drivers installed at that point (not 100% sure) Change the following registry value to 1 (true): HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\SessionManager \MemoryManagement\ClearPageFileAtShutdown Tried to lower even more ram clock Made sure ram timing was set to recommended by manufacturer Verified if motherboard was in good physical condition (yes and its brand new) There is one thing to note, when I got the new motherboard, I installed the new drivers WITHOUT formatting and the I removed the motherboard drivers that I could remove from the control panel (pretty much the first things that have been installed). Could this cause an issue even ON THE OTHER drive (revodrive). Hopefully someone can help me, I am getting tired of this, spending so much money and cannot get this to work correctly. If you need any other information let me know, thank you!

    Read the article

  • Unable to authenticate to Windows Server 2003 for file browsing as non-administrator user.

    - by Fopedush
    I've got a windows server 2003 box containing a raid 5 array I use for mass storage. I want to set up a special non-administrator account that can be used to browse files over the network, with only read access. Ideally I'll map my network drive as this user to avoid accidentally hosing my data, and mount as an administrator user on occasions where I actually need write access. I've created a non-administrator user on the Windows Server box (called "ReadOnly)", and granted the user read permissions on the folders I need. However, when I try to browse to the files, and authenticate as this user, I'm told "Permission denied". If I throw the readOnly user into the administrators group, however, I can authenticate and browse just fine. I am, of course, only attempting to browse to folder for which I have given this user read permissions. Obviously my ReadOnly user is missing some privilege here, but I can't figure out what it is. I've been digging around in group policy editor all day to no avail. What am I missing? Fake Edit: I'm doing my browsing from a Windows 7 box, but I don't think that is relevant.

    Read the article

  • How does one change the UUID of a Volume on Mac OSX 10.6?

    - by Emmel
    Does anyone know how to change the UUID of a Volume? The background for this question is that I have a duplicate UUID issue: I have /Volumes/OldMacHD with a UUID of XYZ. I have /Volumes/Mirror1 with a UUID of XYZ (same UUID! I bet that's because OldMacHD USED to be part of this mirror). I got these UUIDs via 'diskutil info /dev/thatdisknumber | grep UUID'. I'd like to change the UUID of 'Mirror1'. I discovered by chance the 'hfs.util' utility, since these are HFS volumes after all. The man page for hfs.util says that if you issue the -s flag, this changes the UUID. However, if you type hfs.util all by itself, it doesn't show you the -s option at all, just every option besides that! Grr. I tried it anyway: sudo /System/Library/Filesystems/hfs.fs/hfs.util -s /dev/disk4 (the raid volume). Nothing happens. No error message, no success message. UUID exactly the same. I tried it while the volume was unmounted. Any ideas?

    Read the article

  • Repairing inconsistent pages in database

    - by Raj
    We have a SQL 2000 DB. The server crashed due to Raid array failure. Now when we run DBCC CHECKDB, we get an error that there are 27 consistency errors in 9 pages. When we run DBCC PAGE on these pages, we get this: Msg 8939, Level 16, State 106, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (m_freeCnt == freeCnt) failed. Values are 2 and 19. Msg 8939, Level 16, State 108, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (emptySlotCnt == 0) failed. Values are 1 and 0. Since the indicated index is non-clustered and is created by a unique constarint that includes 2 columns, we tried dropping and recreating the index. This resulted in the following error: CREATE UNIQUE INDEX terminated because a duplicate key was found for index ID 2. Most significant primary key is '3280'. The statement has been terminated. However running Select var_id,result_on from tests group by var_id,result_on having count(*)>1 returns 0 rows. Here is what we are planning to do: Restore a pre-server crash copy of the DB and run DBCC CHECKDB If that returns clean, then restore again with no recovery Apply all subequent TLOG backups Stop production app, take a tail log backup and apply that too Drop prod DB and rename the freshly restored DB to make it prod Start prod app Could someone please punch holes in this approach? Maybe, suggest a different approach? What we need is minimum downtime. SQL 2000 DB Size 94 GB The table that has corrupt pages has 460 Million+ rows of data Thanks for the help. Raj

    Read the article

  • Installing Linux on an Asus p8z68-m PRO Motherboard

    - by Holland
    Here is a challenge: how is this done? I've tried disabling the ASM1061 controller in the Onboard Devices section, using Wubi, booting from USB (as I don't have a DVD drive, yet), and even booting from RAID/IDE (with AHCI as the default) to do this. Still, no dice. Google shows up virtually nothing related about Linux and this mobo, apart from a people just saying "disable ASMedia" (which, I assume is the ASM1061 controller, as that's all I see - apart from the USB 3.0, which I disabled already) and it hasn't really helped much. Thus, what is wrong here? Edit My problem is that I cannot boot Linux via USB or a simple Windows installer such as Wubi (for Ubuntu). I wind up getting error messages along the lines of write cache failed, along with many other cryptic error messages similar to the following: [ 1400.351374] sd 4:0:0:0: [sdb] Test WP failed, assume Write Enabled [ 1400.353433] sd 4:0:0:0: [sdb] Asking for cache data failed [ 1400.356601] sd 4:0:0:0: [sdb] Assuming drive cache: write through This seems to be common for Asus P8Z68-M Pro motherboards, with the only notable solution being to "disable ASMedia", which, as I said before, I'm guessing is the ASM1061 controller on the motherboard. Despite already disabling this, I have tried this with both Fedora and Ubuntu without any success. I need to know what I can do about this; has anyone ran into something similar or heard about this issue before? I know these motherboards are relatively new...

    Read the article

  • Server hang - data loss on reboot, post mortem analysis

    - by rovangju
    A development server I'm responsible for (ext3 on raid 5 w/Debian Squeeze) froze up over the weekend and I was forced to reset it, as in unresponsive from KVM/physical keyboard access, no eth devices responding, etc. Not even the backup process ran (Figures, the one time I don't check for confirmation) So after the reset, it turns out that every trace of disk IO activity that should have happened for a period of ~24H is completely gone. The log files have a big gap in the dates and times. As if the writes were never committed to disk, no processes seemed to have run. Luckily it was a weekend and nothing of value would have been lost and I don't suspect a hack. What can I do in post mortem to this event - to prevent it from ever happening again? I've seen this happen before on a completely different machine running FreeBSD. I am rounding up the disk checking tools right now - but there must be more going on! Mount options: /dev/sda1 on / type ext3 (rw,errors=remount-ro) Kernel: Linux dev 2.6.32-5-686-bigmem Disk/Inodes: 13%/3%

    Read the article

  • Intel Rapid Storage Technology (pre-OS) driver installation

    - by Nero theZero
    My desktop machine is built on Gigabyte GA-Z87-UD3H and Gigabyte provides the latest driver for Intel Rapid Storage Technology (IRST), which I installed after installing the OS. Same goes for my Lenovo Thinkpad-T420. And for both machine, checking the controller device under the IDE ATA/ATAPI Controllers section in Device Manager I see the driver has been updated to the latest version. I set the SATA controller to AHCI from BIOS On the desktop machine I have one WD 2TB BLACK & one WD 3TB Green I don’t use RAID, & no chance of using in near future, but according to Intel IRST improves performance in single disk scenario too. Now I have the following questions – What is the actual purpose of IRST (pre-OS install) driver that doesn’t get served with a post-OS driver that I installed? There must be some difference, otherwise there wouldn’t be a pre-OS version of the driver. Right? In the pre-OS procedure (loading the drivers at OS-installation time) after successfully completing the OS installation, do I need that post-OS driver? Because after installing from that one I got a quick launch icon that runs the IRST configuration application. Where do get that after installing the pre-OS driver? As it is “pre-OS”, when I load it at OS-installation time, does it updates anything at BIOS level or anywhere other than HDD? That’s because I’m going to dual boot Windows 7 with Windows 8.1, and after installing Windows 7 when I install Windows 8.1 & load the IRST driver for that, is there any chance of any “overwriting” or OS-incompatibility? In short, is there anything specific to follow while installing the second OS?

    Read the article

  • How does the LeftHand SAN perform in a Production environment?

    - by Keith Sirmons
    Howdy, I previously asked this ServerFault question: Does anyone have experience with lefthands VSA SAN The general consensus looks like it does not perform well enough for a production SQL server even at a light load. So the new question is, How does LeftHand's SAN perform on the HP or Dell dedicated Hardware boxes? We are looking at the Starter SAN with 2 HP nodes in a 2-way replication, 2 ESX servers hosting a total of 2 Active Directory server, 1 MS SQL server, 1 File Server, and 1 General Purpose Server for things like Virus Scan (All Microsoft Server 2005 or 2008). The reason I am looking at LeftHand is for the complete software package. I plan to have a DR site and like how the SAN can perform an Async Replication to the offsite location without having to go back to the Vendor for more licenses. I also like the redundancy built into the Network Raid architecture. I have looked at other SANS and found different faults with them. For example, Dell's EqualLogic: Found that although the individual box is very redundant in hardware, the Data once spanned across multiple boxes is not redundant, if a node goes down you have lost the only copy of the data sitting on that hardware (One thing is certain, all hardware fails... When? is the only question.). I have used an XioTech SAN as well.. Well worth the money BTW, but I think it is overkill for the size of the office I am targeting. The cost to get the hardware redundancy in the XioTech makes it a little out of reach for the budget I am working in. Thank you, Keith

    Read the article

  • Kerberos service on win2k dc will not start following disk failure

    - by iwilson68
    Hi, I have a win2k (mixed mode domain) with 4 DCS. One of these also acts an exchange 2000 server which uses 2 logical volumes from an MSA 2000 array. AD etc is stored on local drives. We experienced a problem last week when the raid array fell back to a redundant controller and this temporarily meant that the two logical drives were not visible to the server for around 5 minutes and a couple of reboots. The log records these Events as Type: Warning Event Source: Disk Event Category: None Event ID: 51 Date: 06/11/2009 Time: 11:46:23 User: N/A Computer: server1 Description: An error was detected on device \Device\Harddisk1\DR1 during a paging operation. Following these problems, the server “kerberos Key Distribution” service refuses to start with an “error.31 a device attached to the system is not functioning”. All other automatic start services (including net logon) are running and there are no DNS issues etc. All devices are also functioning but the two logical MSA disks are now numbered in the Windows Disk Management MMC as 2 and 4 and I suspect that they may have previously been identified as disks 1 & 2 and perhaps windows still sees this as an ongoing failure?? Replication has not been affected but obviously there are many audit failures in the security log relating to users and workstations presumably linked to the Kerberos issue. Attempting to manually start the kerberos service generates the following in the System Log. Event Type: Error Event Source: Service Control Manager Event Category: None Event ID: 7023 Date: 09/11/2009 Time: 09:46:55 User: N/A Computer: Server1 Description: The Kerberos Key Distribution Center service terminated with the following error: A device attached to the system is not functioning. DCDIAG passes all tests except “Advertising” and “Services” which I believe relate directly to the failure of Kerberos only. Any advice would be appreciated.

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here.

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • Dell PowerEdge 1600SC Server won't boot from Fedora 12 DVD because of CD only drive.

    - by studiohack23
    Dell PowerEdge 1600SC Server won't boot from Fedora 12 DVD in the drive because it only supports CDs as I found out after the fact. I'm a complete novice @ servers, so if you need more detail, let me know, and I'll try to provide it. This server is around 4-6 years old. it has "PXE" boot, not sure what that means? This particular server has 3 RAID hard drives. As far as I know, they have all been wiped. I looked up the service tag on Dell, and it has: Compact Disk Drive, 650M, I Internal, Half Height, 48X, BlackHitachi LG Data Storage as its CD drive. Thus, the CD drive does not support DVDs, so installation will have to be via a live CD. However, I'm trying to put Amahi Home Server (http://www.amahi.org/), and Live CD/USB stick installs are not recommended unless one is an expert Linux user. any suggestions as to how to get around this? PROBLEM SOLVED! THANKS for all the help!

    Read the article

  • Backup and Archive Strategy Question

    - by OneNerd
    I am having trouble finding a backup strategy for our code assets that 'just works' without any manual intervention. Goal is to have an off-site backup (a synchronized one) so that when we check-in files, create builds, etc. to the network drive, the entire folder structure is automatically synchronized and backed-up (in real time, or 1x per day) at some off-site location so if our office blows up, we don't lose all of our data. I have looked into some online backup services, but have not yet had any success. Some are quirky/buggy, others limit file size and/or kinds of files (which doesn't work well for developer files). Everything gets checked in and saved to a single server (on a Raid Mirror), so we just need to have a folder on that server backed up/synchronized to some off-site location. So my question is this. What are you using for your off-site backup strategy. What software, system, or service? Is there a be-all/end-all system of backing up your code assets that I just haven't found yet? Thanks

    Read the article

  • Switch Windows 8 from a hybrid MBR/GPT => GPT only on Macbook Pro Retina

    - by Sid
    I used DiskUtility+Bootcamp Wizard to setup my hard drive for Windows 8 (final MSDN). Somewhere in that process, the Apple tools turned my GPT disk into a hybrid MBR/GPT. All my 4 primary MBR partitions are used up, so when I try turning on Bitlocker in Windows 8, it complains about not finding a System drive. I know on Windows 8 the Bitlocker setup tries to create the 200(?)MB system partition if it's missing. However with all 4 partitions filled I suspect it can't create system drive = it can't find it = throws back an error like "BitLocker Setup could not find a target system drive. You may need to manually prepare your drive for BitLocker". I've already tried disabling hibernation, swap file etc. Now I'm thinking that if I were to get rid of the MBR scheme altogether, perhaps I can be alright within the GPT world without MBR's 4 primary partitions limit. So, how can I get rid of the MBR tables on the hybrid scheme in a manner that still leaves Mac OS and Windows 8 in working conditions? Details: Hardware is the MacbookPro Retina. Primary MBR partitions are consumed as follows: EFI partition HFS+ partition (=encrypted, therefore ="Apple_CoreStorage") HFS+ partition (Recovery partition, contains unencrypted Mac bootloader) NTFS partition (Windows8 all-in-one partition) diskutil list output sid-mbpr:~ sid$ diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *251.0 GB disk0 1: EFI 209.7 MB disk0s1 2: Apple_CoreStorage 160.0 GB disk0s2 3: Apple_Boot Recovery HD 650.0 MB disk0s3 4: Microsoft Basic Data Win8 90.1 GB disk0s4 GPT vs MBR addresses sid-mbpr:~ sid$ sudo gptsync /dev/rdisk0 Password: Current GPT partition table: # Start LBA End LBA Type 1 40 409639 EFI System (FAT) 2 409640 312909639 Unknown 3 312909640 314179175 Mac OS X Boot 4 314179584 490233855 Basic Data Current MBR partition table: # A Start LBA End LBA Type 1 1 409639 ee EFI Protective 2 409640 312909639 ac Apple RAID 3 312909640 314179175 ab Mac OS X Boot 4 * 314179584 490233855 07 NTFS/HPFS Status: GPT partition of type 'Unknown' found, will not touch this disk.** **: Ignore this message, the gptsync tool is old and doesn't understand the UUID for "Apple_CoreStorage" / FileVault2 partitions. Since LBA addresses are alright, safe to ignore this message.

    Read the article