Search Results

Search found 30575 results on 1223 pages for 'number systems'.

Page 686/1223 | < Previous Page | 682 683 684 685 686 687 688 689 690 691 692 693  | Next Page >

  • SQL SERVER – Removing Leading Zeros From Column in Table – Part 2

    - by pinaldave
    Earlier I wrote a blog post about Remvoing Leading Zeros from Column In Table. It was a great co-incident that my friend Madhivanan (no need of introduction for him) also post a similar article over on BeyondRelational.com. I strongly suggest to read his blog as well as he has suggested some cool solutions to the same problem. On original blog post asked two questions 1) if my sample for testing is correct and 2) If there is any better method to achieve the same. The response was amazing. I am proud on our SQL Community that we all keep on improving on each other’s contribution. There are some really good suggestions as a comment. Let us go over them right now. Improving the ResultSet I had missed including all zeros in my sample set which was an overlook. Here is the new sample which includes all zero values as well. USE tempdb GO -- Create sample table CREATE TABLE Table1 (Col1 VARCHAR(100)) INSERT INTO Table1 (Col1) SELECT '0001' UNION ALL SELECT '000100' UNION ALL SELECT '100100' UNION ALL SELECT '000 0001' UNION ALL SELECT '00.001' UNION ALL SELECT '01.001' UNION ALL SELECT '0000' GO Now let us go over some of the fantastic solutions which we have received. Response from Rainmaker SELECT CASE PATINDEX('%[^0 ]%', Col1 + ' ‘') WHEN 0 THEN '' ELSE SUBSTRING(Col1, PATINDEX('%[^0 ]%', Col1 + ' '), LEN(Col1)) END FROM Table1 Response from Harsh Solution 1 SELECT SUBSTRING(Col1, PATINDEX('%[^0 ]%', Col1 + 'a'), LEN(Col1)) FROM Table1 Response from Harsh Solution 2 SELECT RIGHT(Col1, LEN(Col1)+1 -PATINDEX('%[^0 ]%', Col1 + 'a' )) FROM Table1 Response from lucazav SELECT T.Col1 , label = CAST( CAST(REPLACE(T.Col1, ' ', '') AS FLOAT) AS VARCHAR(10)) FROM Table1 AS T Response from iamAkashSingh SELECT REPLACE(LTRIM(REPLACE(col1,'0',' ')),' ','0') FROM table1 Here is the resultset of above scripts. It will remove any leading zero or space and will display the number accordingly. If you believe there is a better solution, please leave a comment. I am just glad to see so many various responses and all of them teach us something new. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Function, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • How can I promote clean coding at my workplace?

    - by Michael
    I work with a lot of legacy Java and RPG code on an internal company application. As you might expect, a lot of the code is written in many different styles, and often is difficult to read because of poorly named variables, inconsistent formatting, and contradictory comments (if they're there at all). Also, a good amount of code is not robust. Many times code is pushed to production quickly by the more experienced programmers, while code by newer programmers is held back by "code reviews" that IMO are unsatisfactory. (They usually take the form of, "It works, must be ok," than a serious critique of the code.) We have a fair number of production issues, which I feel could be lessened by giving more thought to the original design and testing. I have been working for this company for about 4 months, and have been complimented on my coding style a couple of times. My manager is also a fan of cleaner coding than is the norm. Is it my place to try to push for better style and better defensive coding, or should I simply code in the best way I can, and hope that my example will help others see how cleaner, more robust code (as well as aggressive refactoring) will result in less debugging and change time?

    Read the article

  • Tools for retrieving and modifying multi-value attributes in Microsoft ActiveDirectory

    - by Justin
    Most attributes in MSAD are single-valued and pose no problem. I am familiar with the dsquery user -samid jdoe | dsmod -webpg "http://some.url/" method. However, some attributes are multi-valued, such as telephone number and webpage. These values can be managed through the Active Directory Users & Computers Microsoft Console (dsa.msc) via the dialogue shown by clicking on the "Other..." button, but I'd really rather script the modifications. It seems to me that dsmod & dsget do not support multi-value retrieval and editing; only the first value of the set seems to be accesible. Am I correct? If I am not correct, I would appreciate a syntax example. If I am correct, would you please recommend an alternative scriptable tool that can handle multi-value attributes? The more "official and supported" the tool, the better.

    Read the article

  • preparing to migrate MOSS 2007 SP1 content into new server with MOSS 2007 SP2 with the same server n

    - by Albert Widjaja
    To All Experts here, I'd like to perform a MOSS server content migration from the existing single instance server (SQL Server 2008, Windows Server 2008, SharePoint 2007 SP1) all in one and by maintaining the server name only, here's what I had in my migration plan document outline: I have created the new Windows Server 2008 R2 + SQL Server 2008 SP1 and MOSS 2007 SP2 after that: Backup MOSS_ContentDB from SQL Server 2008 SSMS (does this enough to cover all top level sites and its content in the library and doc. repository ?) Backup all top level sites from CA site using the CA Sites backup and restore tools. turn off the old MOSSDEV01 (current server) rename the existing server (TempServ01) into MOSSDEV01 (so that the user bookmark and other link inside MOSS site still working) perform restore of the DB restore the site collection and its content from the backup is that the correct way to do it ? I haven't execute the server configuration wizard to create the same port number of the SSP, CA and the SQL Server DB yet. Any idea and suggestion would be greatly appreciated Thanks.

    Read the article

  • Book review: Microsoft System Center Enterprise Suite Unleashed

    - by BuckWoody
    I know, I know – what’s a database guy doing reading a book on System Center? Well, I need it from time to time. System Center is actually a collection of about 7 different products that you can use to manage and monitor your software and hardware, from drive space through Microsoft Office, UNIX systems, and yes, SQL Server. It’s that last part I care about the most, and so I’ve dealt with Data Protection Manager and System Center Operations Manager (I call it SCOM) in SQL Server. But I wasn’t familiar with the rest of the suite nor was I as familiar as I needed to be with the “Essentials” release – a separate product that groups together the main features of System Center into a single offering for smaller organizations. These companies usually run with a smaller IT shop, so they sometimes opt for this product to help them monitor everything, including SQL Server. So I picked up “Microsoft System Center Enterprise Suite Unleashed” by Chris Amaris and a cast of others. I don’t normally like to get a technical book by multiple authors – I just find that most of the time it’s quite jarring to switch from author to author, but I think this group did pretty well here.  The first chapter on introducing System Center has helped me talk with others about what the product does, and which pieces fit well together with SQL Server. The writing is well done, and I didn’t find a jump from author to author as I went along. The information is sequential, meaning that they lead you from install to configuration and then use. It’s very much a concepts-and-how-to book, and a big one at that – over 950 pages of learning! It was a pretty quick read, though, since I skipped the installation parts and there are lots of screenshots. While I’m not sure you’d be an expert on the product when you finish reading this book, but I would say you’re more than halfway there. I would say it suits someone that learns through examples the best, since they have a lot of step-by-step examples I do recommend that you take a look if you have to interact with this product, or even if you are a smaller shop and you’re the primary IT resource. The last few chapters deal with System Center Essentials, and honestly it was the best part of the book for me. Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • SQL SERVER – A Puzzle – Fun with SEQUENCE in SQL Server 2012 – Guess the Next Value

    - by pinaldave
    Yesterday my friend Vinod Kumar wrote excellent blog post on SQL Server 2012: Using SEQUENCE. I personally enjoyed reading the content on this subject. While I was reading the blog post, I thought of very simple new puzzle. Let us see if we can try to solve it and learn a bit more about Sequence. Here is the script, which I executed. USE TempDB GO -- Create sequence CREATE SEQUENCE dbo.SequenceID AS BIGINT START WITH 3 INCREMENT BY 1 MINVALUE 1 MAXVALUE 5 CYCLE NO CACHE; GO -- Following will return 3 SELECT next value FOR dbo.SequenceID; -- Following will return 4 SELECT next value FOR dbo.SequenceID; -- Following will return 5 SELECT next value FOR dbo.SequenceID; -- Following will return which number SELECT next value FOR dbo.SequenceID; -- Clean up DROP SEQUENCE dbo.SequenceID; GO Above script gave me following resultset. 3 is the starting value and 5 is the maximum value. Once Sequence reaches to maximum value what happens? and WHY? Bonus question: If you use UNION between 2 SELECT statement which uses UNION, it also throws an error. What is the reason behind it? Can you attempt to answer this question without running this code in SQL Server 2012. I am very confident that irrespective of SQL Server version you are running you will have great learning. I will follow up of the answer in comments below. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Puzzle, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Data Modeling Resources

    - by Dejan Sarka
    You can find many different data modeling resources. It is impossible to list all of them. I selected only the most valuable ones for me, and, of course, the ones I contributed to. Books Chris J. Date: An Introduction to Database Systems – IMO a “must” to understand the relational model correctly. Terry Halpin, Tony Morgan: Information Modeling and Relational Databases – meet the object-role modeling leaders. Chris J. Date, Nikos Lorentzos and Hugh Darwen: Time and Relational Theory, Second Edition: Temporal Databases in the Relational Model and SQL – all theory needed to manage temporal data. Louis Davidson, Jessica M. Moss: Pro SQL Server 2012 Relational Database Design and Implementation – the best SQL Server focused data modeling book I know by two of my friends. Dejan Sarka, et al.: MCITP Self-Paced Training Kit (Exam 70-441): Designing Database Solutions by Using Microsoft® SQL Server™ 2005 – SQL Server 2005 data modeling training kit. Most of the text is still valid for SQL Server 2008, 2008 R2, 2012 and 2014. Itzik Ben-Gan, Lubor Kollar, Dejan Sarka, Steve Kass: Inside Microsoft SQL Server 2008 T-SQL Querying – Steve wrote a chapter with mathematical background, and I added a chapter with theoretical introduction to the relational model. Itzik Ben-Gan, Dejan Sarka, Roger Wolter, Greg Low, Ed Katibah, Isaac Kunen: Inside Microsoft SQL Server 2008 T-SQL Programming – I added three chapters with theoretical introduction and practical solutions for the user-defined data types, dynamic schema and temporal data. Dejan Sarka, Matija Lah, Grega Jerkic: Training Kit (Exam 70-463): Implementing a Data Warehouse with Microsoft SQL Server 2012 – my first two chapters are about data warehouse design and implementation. Courses Data Modeling Essentials – I wrote a 3-day course for SolidQ. If you are interested in this course, which I could also deliver in a shorter seminar way, you can contact your closes SolidQ subsidiary, or, of course, me directly on addresses [email protected] or [email protected]. This course could also complement the existing courseware portfolio of training providers, which are welcome to contact me as well. Logical and Physical Modeling for Analytical Applications – online course I wrote for Pluralsight. Working with Temporal data in SQL Server – my latest Pluralsight course, where besides theory and implementation I introduce many original ways how to optimize temporal queries. Forthcoming presentations SQL Bits 12, July 17th – 19th, Telford, UK – I have a full-day pre-conference seminar Advanced Data Modeling Topics there.

    Read the article

  • gparted won't boot from liveCD

    - by ant2009
    Hello, Fedora 12 2.6.32.9-70.fc12.i686 I downloaded the gparted iso and burnt it to a CD. gparted-live-0.5.2-1 This GParted Live was created by: create-gparted-live -l en -b u -e e -d sid -m http://free.nchc.org.tw/debian -s http://free.nchc.org.tw/debian-security -g http://free.nchc.org.tw/drbl-core -n 2.6.32-3 -i 0.5.2-1 The files and folders: isolinux live syslinux COPYING GParted-Live-Version I put the disk in and reboot. Nothing happens. I just get a flashing cursor in the top left hand corner. I then have to switch of the power button to get it to reboot. I have done this a number of time and the results are the same. Can anyone tell me how to boot from the gparted liveCD? Many thanks for any suggestions,

    Read the article

  • Good HDMI splitter/switch solution

    - by Mehper C. Palavuzlar
    I have a full HD TV which has only 2 HDMI ports on it. Since I have more than 2 devices I connect to TV (e.g. laptop, game console, DVD player), it becomes uncomfortable to plug in and plug out HDMI cables every time I need to use the relevant device. I need a cheap solution to increase the number of my HDMI ports at least to 3. What type of splitter/switch do you recommend? Does the quality of splitter matter, or do they all produce the same audio & video quality?

    Read the article

  • determining trustee of directories on novell netware volume

    - by Matt Delves
    Currently there are a lot of directories (user home directories that may no longer exist) on a netware volume. As this number is significant, I'm in need of an easy way of determining if there are any trustee's (existing users who have permissions to the directory) on the directories in question. So, several things I'm after. 1) Are there any applications, that take the input of a list of directories and output the same list with the trustee's attached? 2) Is there an easy way to determine the trustee's without looking at Console One? Thanks, Matt.

    Read the article

  • Remote file access.

    - by Rob Rob
    Hi, We're needing to provide remote (read/write) access to a number of files on our network to several users (some technical, some non-technical) who will be running Windows. The non technical users will need to be able to access their files in an easy to use manner. From previous experience, we could do this with: (some sort of) VPN SSH and something like Dokan (i've only previously done this on linux with sshfs) WebDav FTP VPN and SSH access are more open that we need at present, so I'm leaning towards webdav, however I only have limited experience of it (setting up an SVN server several years ago), but my understanding is that users can access it through windows explorer. FTP I haven't had much experience of, as I've always used SFTP via ssh - but i'd imagine we could make this work in a similar way to ssh. So my question is - have I missed any obvious candidates for this task, or if webdav is (or isn't) suitable what are the security implications of using it for this (obviously https will be used for the transfers, etc). Thanks, Rob.

    Read the article

  • Forwarding port to a VM - How to?

    - by Peter Gadd
    I use Win 8 Ent x64 on my PC, and I also have a Win 7 VMware virtual machine set up using a bridged network adapter. The IPv4 number for the Win 7 VM is 192.168.1.115. I require access to the VM from the Internet through port 1688. How do I set up port forwarding to achieve this? My router is a Cisco Linksys WAG120N. ========= If you require any further information to help me with this, I will gladly supply it. ========= Thanks in advance.

    Read the article

  • Server Configuration / Important Parameter for 500Req/Second

    - by Sparsh Gupta
    I am configuring a server to be used as nginx server for a very heavy traffic website. It is expected to receive traffic from a large number of IP addresses simultaneously. It is expected to get 500Req/Second with atleast 20Million unique IPs connecting it. One of the problems I noticed in my previos server was related to iptables / ipconntrack. I am not aware of this behaviour and would be glad to know which all parameters of a ubuntu / debian (32/64) bit machine should I tweek to get maximum performance from the server. I can put in a lot of RAM on the server but mission critical task is the response times. We ideally dont want any connection to be hanging / timing out / waiting and want as low as possible overall response times. P.S. We are also looking for a kick ass freelancer system admin who can help us figuring / setting this all up. Reach me incase you have some spare time and interested in working on some very heavy traffic website servers.

    Read the article

  • Oracle Utilities Application Framework V4.1 Group Fix 4 available

    - by ACShorten
    Oracle Utilities Application Framework V4.1 Group Fix 4 is available from My Oracle Support as Patch 13523301. This Group Fix contains a number of enhancements and keeps fixes up to date to the latest patch level. The enhancements included in this Group Fix include: UI Hints - In previous group fixes of the Oracle Utilities Application Framework the infrastructure to support UI Hints was introduced. This group fix completes the release of this functionality. Prior to this enhancement, products and implementers typically would build at least one UI Map per Business Object to display and/or maintain the object. Whilst, this can be generated using the UI Map maintenance function and stored, this enhancement allows additional tags and elements to be added to the Business Object directly to allow dynamic generation of the UI Map for maintenance and viewing the object. This reduces the need to generate and build a UI Map at all for that object. This will reduce maintenance effort of maintaining the product and implementation by eliminating the need to maintain the HTML for the UI Map. This also allows lower skilled personnel to maintain the system. Help and working examples are available from the View schema attributes and node names option from the Schema Tips dashboard zone. For example: Note: For examples of the hints, refer to an of the following Business Objects F1_OutcomeStyleLookup, F1-TodoSumEmailType, F1-BOStatusReason or F1-BIGeneralMasterConfig. Setting batch log file names -  By default the batch infrastructure supplied with the Oracle Utilities Application Framework sets the name and location of the log files to set values. In Group Fix 4 a set of user exits have been added to allow implementers and partners to set their own filename and location.  Refer to the Release Notes in the download for more details.

    Read the article

  • Certificate Template Missing from "Certificate Template to Issue"

    - by Adam Robinson
    I'm having a problem similar to that posted in this question: Missing Certificate template From certificate to issue The short version is that I've created a duplicate certificate template and I'm trying to add it to my domain CA so that I can issue certificates with it. However, when I go into the Certification Authority MMC and go to "Certificate Templates - New - Certificate Template To Issue", my template is missing (along with quite a number of other templates that are present in the domain). Unlike the previous question, however, my CA is running on Server 2008 R2 Enterprise. Our organization has a single DC and a single CA, so I'm not seeing where there could be propagation delay. Any ideas how to get my template to show so that I can issue certificates?

    Read the article

  • Rescue overdue offshore projects and convince management to use automated tests

    - by oazabir
    I have published two articles on codeproject recently. One is a story where an offshore project was two months overdue, my friend who runs it was paying the team from his own pocket and he was drowning in ever increasing number of change requests and how we brainstormed together to come out of that situation. Tips and Tricks to rescue overdue projects Next one is about convincing management to go for automated test and give developers extra time per sprint, at the cost of reduced productivity for couple of sprints. It’s hard to negotiate this with even dev leads, let alone managers. Whenever you tell them - there’s going to be less features/bug fixes delivered for next 3 or 4 sprints because we want to automate the tests and reduce manual QA effort; everyone gets furious and kicks you out of the meeting. Especially in a startup where every sprint is jam packed with new features and priority bug fixes to satisfy various stakeholders, including the VCs, it’s very hard to communicate the benefits of automated tests across the board. Let me tell you of a story of one of my startups where I had the pleasure to argue on this and came out victorious. How to convince developers and management to use automated test instead of manual test If you like these, please vote for me!

    Read the article

  • C#: My World Clock

    - by Bruce Eitman
    [Placeholder:  I will post the entire project soon] I have been working on cleaning my office of 8 years of stuff from several engineers working on many projects.  It turns out that we have a few extra single board computers with displays, so at the end of the day last Friday I though why not create a little application to display the time, you know, a clock.  How difficult could that be?  It turns out that it is quite simple – until I decided to gold plate the project by adding time displays for our offices around the world. I decided to use C#, which actually made creating the main clock quite easy.   The application was simply a text box and a timer.  I set the timer to fire a couple of times a second, and when it does use a DateTime object to get the current time and retrieve a string to display. And I could have been done, but of course that gold plating came up.   Seems simple enough, simply offset the time from the local time to the location that I want the time for and display it.    Sure enough, I had the time displayed for UK, Italy, Kansas City, Japan and China in no time at all. But it is October, and for those of us still stuck with Daylight Savings Time, we know that the clocks are about to change.   My first attempt was to simply check to see if the local time was DST or Standard time, then change the offset for China.  China doesn’t have Daylight Savings Time. If you know anything about the time changes around the world, you already know that my plan is flawed – in a big way.   It turns out that the transitions in and out of DST take place at different times around the world.   If you didn’t know that, do a quick search for “Daylight Savings” and you will find many WEB sites dedicated to tracking the time changes dates, and times. Now the real challenge of this application; how do I programmatically find out when the time changes occur and handle them correctly?  After a considerable amount of research it turns out that the solution is to read the data from the registry and parse it to figure out when the time changes occur. Reading Time Change Information from the Registry Reading the data from the registry is simple, using the data is a little more complicated.  First, reading from the registry can be done like:             byte[] binarydata = (byte[])Registry.GetValue("HKEY_LOCAL_MACHINE\\Time Zones\\Eastern Standard Time", "TZI", null);   Where I have hardcoded the registry key for example purposes, but in the end I will use some variables.   We now have a binary blob with the data, but it needs to be converted to use the real data.   To start we will need a couple of structs to hold the data and make it usable.   We will need a SYSTEMTIME and REG_TZI_FORMAT.   You may have expected that we would need a TIME_ZONE_INFORMATION struct, but we don’t.   The data is stored in the registry as a REG_TZI_FORMAT, which excludes some of the values found in TIME_ZONE_INFORMATION.     struct SYSTEMTIME     {         internal short wYear;         internal short wMonth;         internal short wDayOfWeek;         internal short wDay;         internal short wHour;         internal short wMinute;         internal short wSecond;         internal short wMilliseconds;     }       struct REG_TZI_FORMAT     {         internal long Bias;         internal long StdBias;         internal long DSTBias;         internal SYSTEMTIME StandardStart;         internal SYSTEMTIME DSTStart;     }   Now we need to convert the binary blob to a REG_TZI_FORMAT.   To do that I created the following helper functions:         private void BinaryToSystemTime(ref SYSTEMTIME ST, byte[] binary, int offset)         {             ST.wYear = (short)(binary[offset + 0] + (binary[offset + 1] << 8));             ST.wMonth = (short)(binary[offset + 2] + (binary[offset + 3] << 8));             ST.wDayOfWeek = (short)(binary[offset + 4] + (binary[offset + 5] << 8));             ST.wDay = (short)(binary[offset + 6] + (binary[offset + 7] << 8));             ST.wHour = (short)(binary[offset + 8] + (binary[offset + 9] << 8));             ST.wMinute = (short)(binary[offset + 10] + (binary[offset + 11] << 8));             ST.wSecond = (short)(binary[offset + 12] + (binary[offset + 13] << 8));             ST.wMilliseconds = (short)(binary[offset + 14] + (binary[offset + 15] << 8));         }             private REG_TZI_FORMAT ConvertFromBinary(byte[] binarydata)         {             REG_TZI_FORMAT RTZ = new REG_TZI_FORMAT();               RTZ.Bias = binarydata[0] + (binarydata[1] << 8) + (binarydata[2] << 16) + (binarydata[3] << 24);             RTZ.StdBias = binarydata[4] + (binarydata[5] << 8) + (binarydata[6] << 16) + (binarydata[7] << 24);             RTZ.DSTBias = binarydata[8] + (binarydata[9] << 8) + (binarydata[10] << 16) + (binarydata[11] << 24);             BinaryToSystemTime(ref RTZ.StandardStart, binarydata, 4 + 4 + 4);             BinaryToSystemTime(ref RTZ.DSTStart, binarydata, 4 + 16 + 4 + 4);               return RTZ;         }   I am the first to admit that there may be a better way to get the settings from the registry and into the REG_TXI_FORMAT, but I am not a great C# programmer which I have said before on this blog.   So sometimes I chose brute force over elegant. Now that we have the Bias information and the start date information, we can start to make sense of it.   The bias is an offset, in minutes, from local time (if already in local time for the time zone in question) to get to UTC – or as Microsoft defines it: UTC = local time + bias.  Standard bias is an offset to adjust for standard time, which I think is usually zero.   And DST bias is and offset to adjust for daylight savings time. Since we don’t have the local time for a time zone other than the one that the computer is set to, what we first need to do is convert local time to UTC, which is simple enough using:                 DateTime.Now.ToUniversalTime(); Then, since we have UTC we need to do a little math to alter the formula to: local time = UTC – bias.  In other words, we need to subtract the bias minutes. I am ahead of myself though, the standard and DST start dates really aren’t dates.   Instead they indicate the month, day of week and week number of the time change.   The dDay member of SYSTEM time will be set to the week number of the date change indicating that the change happens on the first, second… day of week of the month.  So we need to convert them to dates so that we can determine which bias to use, and when to change to a different bias.   To do that, I wrote the following function:         private DateTime SystemTimeToDateTimeStart(SYSTEMTIME Time, int Year)         {             DayOfWeek[] Days = { DayOfWeek.Sunday, DayOfWeek.Monday, DayOfWeek.Tuesday, DayOfWeek.Wednesday, DayOfWeek.Thursday, DayOfWeek.Friday, DayOfWeek.Saturday };             DateTime InfoTime = new DateTime(Year, Time.wMonth, Time.wDay == 1 ? 1 : ((Time.wDay - 1) * 7) + 1, Time.wHour, Time.wMinute, Time.wSecond, DateTimeKind.Utc);             DateTime BestGuess = InfoTime;             while (BestGuess.DayOfWeek != Days[Time.wDayOfWeek])             {                 BestGuess = BestGuess.AddDays(1);             }             return BestGuess;         }   SystemTimeToDateTimeStart gets two parameters; a SYSTEMTIME and a year.   The reason is that we will try this year and next year because we are interested in start dates that are in the future, not the past.  The function starts by getting a new Datetime with the first possible date and then looking for the correct date. Using the start dates, we can then determine the correct bias to use, and the next date that time will change:             NextTimeChange = StandardChange;             CurrentBias = TimezoneSettings.Bias + TimezoneSettings.DSTBias;             if (DSTChange.Year != 1 && StandardChange.Year != 1)             {                 if (DSTChange.CompareTo(StandardChange) < 0)                 {                     NextTimeChange = DSTChange;                     CurrentBias = TimezoneSettings.StdBias + TimezoneSettings.Bias;                 }             }             else             {                 // I don't like this, but it turns out that China Standard Time                 // has a DSTBias of -60 on every Windows system that I tested.                 // So, if no DST transitions, then just use the Bias without                 // any offset                 CurrentBias = TimezoneSettings.Bias;             }   Note that some time zones do not change time, in which case the years will remain set to 1.   Further, I found that the registry settings are actually wrong in that the DST Bias is set to -60 for China even though there is not DST in China, so I ignore the standard and DST bias for those time zones. There is one thing that I have not solved, and don’t plan to solve.  If the time zone for this computer changes, this application will not update the clock using the new time zone.  I tell  you this because you may need to deal with it – I do not because I won’t let the user get to the control panel applet to change the timezone. Copyright © 2012 – Bruce Eitman All Rights Reserved

    Read the article

  • Object model design: collections on classes

    - by Luke Puplett
    Hi all, Consider Train.Passengers, what type would you use for Passengers where passengers are not supposed to be added or removed by the consuming code? I'm using .NET Framework, so this discussion would suit .NET, but it could apply to a number of modern languages/frameworks. In the .NET Framework, the List is not supposed to be publicly exposed. There's Collection and ICollection and guidance, which I tend to agree with, is to return the closest concrete type down the inheritance tree, so that'd be Collection since it is already an ICollection. But Collection has read/write semantics and so possibly it should be a ReadOnlyCollection, but its arguably common sense not to alter the contents of a collection that you don't have intimate knowledge about so is it necessary? And it requires extra work internally and can be a pain with (de)serialization. At the extreme ends I could just return Person[] (since LINQ now provides much of the benefits that previously would have been afforded by a more specified collection) or even build a strongly-typed PersonCollection or ReadOnlyPersonCollection! What do you do? Thanks for your time. Luke

    Read the article

  • Get the Information You Need. Delivered.

    - by Get Proactive Customer Adoption Team
    Untitled Document Don’t Take Chances with Alerts—Get Hot Topics When Oracle Support publishes an alert, how do you find out about it? I can see any number of ways you might stumble onto an alert that you need. For example, if you are visiting My Oracle Support in search of answers under the Knowledge tab and happen to notice, and click on, the Alert tab the under the Knowledge Article region, you might see an alert listed for one of the products you use. There are other ways… like subscribing to one of the Oracle Blogs and finding the alert in your RSS feed because the blogger decided to write up that topic for the latest post. I’m sure your colleagues sometimes pass on critical alerts for your products, I hope, giving you the information before you needed it. Well, no matter how you learn about an alert, the important point is that you get the correct information in a timely way. Right? I must admit, the ‘magic’ required to find out via these methods makes me nervous. Rather than leave it to chance, I think you need a more reliable way to stay informed and receive alerts for your products when Oracle publishes them. You may not be aware of it, but there is a better way. Oracle Premier Support Customers can leverage the “Hot Topics E-Mail.” You select the products and topics that interest you. Based on your choices, the system sends you the support related information when Oracle Support publishes it. This way you and I can both relax, knowing you’ll have ready access to the alerts you need, and enjoy the breadth of support related information you choose to subscribe to. This can include recently updated Knowledge base articles, new bugs, and product news. If I’ve convinced you, you will want to know how to set up and subscribe to the Hot Topics E-Mail. The complete guide, Doc ID 793436.1, is waiting for you. Follow the instructions in the document, and you will always stay on top of the latest information from Oracle Support.

    Read the article

  • No endpoint listening at.........

    - by Michael Stephenson
    I was having some very frustrating behaviour on our build server and while I found a number of articles online with similar error messages none of them helped me.  I thought I would just explain this here incase if helps me or anyone else in future.The error message we were getting is:There was no endpoint listening at http://localhostStubs.ExternalApplication/SampleService.svc that could accept the message. This is often caused by an incorrect address or SOAP action. See InnerException, if present, for more detailsOur scenario is as follows:We have a solution where a WCF service application hosting the WCF routing service is listening to the Windows Azure Service Bus Relay.  We have an acceptance test project in the solution which sends a message to the service bus which is then received by the WCF routing service and routed to SampleService.svc which is hosted in another IIS application on the same box.  A response is flowed back through to the test.  In the tests there are 5 scenarios simulating a successful message, and various error conditions.  On my developer machine it was working absolutely fine every time, and a clean build on my developer machine worked fine.  On the build server however one or more of the tests would fail each time with the above error message.  There didnt seem to be any pattern to which test would fail.The solution was building on a Windows 2008 R2 machine with IIS 7 and AppFabric Server installed with auto-start configured for the IIS Application which would be listening to service bus.After lots of searching online and looking at logs etc it turned out to be a simple solution to just restart the WAS service (Windows Process Activation Service) and the services it advised you to restart with it.  Hope this helps someone else

    Read the article

  • How do I see what connections are being made?

    - by Coldblackice
    My DDWRT router is showing that my computer has a connection count around 600! The router is at 100% CPU use. How can I see what's making all the connections? So far, I've opened up Resource Monitor and checked the network tab. I can sort by which program is using the most network bandwidth (Pale Moon browser), but I can't see what's making all of the connections. Or rather, where all the connections are being toward (trying to find what tab must be making all of these connections). I've also tried netstat -A, but it apparently doesn't show the actual number of connections being made. At least, the list of established connections isn't very long, by any means (like enough to account for the 500+ connections apparently being made.

    Read the article

  • Want to Run OS Commands From WLST?

    - by Bala Kothandaraman
    If you spend a lot of time with WLST in the interactive mode, I am sure you have opened another command prompt/shell to check something at the OS file system level. If you wonder whether can execute an OS command from within WLST prompt, the answer is "Yes". This is very convenient similar to how you can execute OS commands from within "Vi" editor. In fact this feature is not from WLST but from underlying Jython. There is "os" module in Jython that provides a unified interface to a number of operating system functions. There is "system" function in the "os" module that can take a OS command as a string input and returns either "0" or "1" depends on whether the command was successful or failed. So this feature can also be used with scripting mode where the return code can be verified for further processing in the script. For eg. os.system(r'dir c:\bea') can list the contents of the bea folder under c drive. Notice the use of the preceding 'r' for escaping the entire string.

    Read the article

  • MyTop doesn't display executed queries

    - by recluze
    Hi, I'm trying to use mytop for figuring out what queries are being executed and how long they take. I can connect properly to the db but MySQL on localhost (5.1.41-3ubuntu12.8) up 0+01:50:47 [09:30:43] Queries: 3.0 qps: 0 Slow: 0.0 Se/In/Up/De(%): 68767/00/00/00 Key Efficiency: 99.1% Bps in/out: 0.0/ 1.2 Id User Host/IP DB Time Cmd Query or State -- ---- ------- -- ---- --- -------------- 225 root localhost 0 Query show full processlist 186 joom localhost culinary 5684 Sleep The number of queries increases over time but the queries themselves do not appear in the list. Is there some type of configuration that I need to do to enable it?

    Read the article

  • MySQL open files limit

    - by Brian
    This question is similar to set open_files_limit, but there was no good answer. I need to increase my table_open_cache, but first I need to increase the open_files_limit. I set the option in /etc/mysql/my.cnf: open-files-limit = 8192 This worked fine in my previous install (Ubuntu 8.04), but now in Ubuntu 10.04, when I start the server up, open_files_limit is reported to be 1710. That seems like a pretty random number for the limit to be clipped to. Anyway, I tried getting around it by adding a line like this in /etc/security/limits.conf: mysql hard nofile 8192 I also tried adding this to the pre-start script in mysql's upstart config (/etc/init/mysql.conf): ulimit -n 8192 Obviously neither of those things worked. So where is the hoop that has been added between Ubuntu 8.04 and 10.04 through which I must jump in order to actually increase the open files limit?

    Read the article

  • SQL SERVER – DATEDIFF – Accuracy of Various Dateparts

    - by pinaldave
    I recently received the following question through email and I found it very interesting so I want to share it with you. “Hi Pinal, In SQL statement below the time difference between two given dates is 3 sec, but when checked in terms of Min it says 1 Min (whereas the actual min is 0.05Min) SELECT DATEDIFF(MI,'2011-10-14 02:18:58' , '2011-10-14 02:19:01') AS MIN_DIFF Is this is a BUG in SQL Server ?” Answer is NO. It is not a bug; it is a feature that works like that. Let us understand that in a bit more detail. When you instruct SQL Server to find the time difference in minutes, it just looks at the minute section only and completely ignores hour, second, millisecond, etc. So in terms of difference in minutes, it is indeed 1. The following will also clear how DATEDIFF works: SELECT DATEDIFF(YEAR,'2011-12-31 23:59:59' , '2012-01-01 00:00:00') AS YEAR_DIFF The difference between the above dates is just 1 second, but in terms of year difference it shows 1. If you want to have accuracy in seconds, you need to use a different approach. In the first example, the accurate method is to find the number of seconds first and then divide it by 60 to convert it to minutes. SELECT DATEDIFF(second,'2011-10-14 02:18:58' , '2011-10-14 02:19:01')/60.0 AS MIN_DIFF Even though the concept is very simple it is always a good idea to refresh it. Please share your related experience with me through your comments. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL DateTime, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

< Previous Page | 682 683 684 685 686 687 688 689 690 691 692 693  | Next Page >