  • Polling servers at the same port - Threads and Java

    - by John
    Hi there. I'm currently busy working on an IP ban tool for the early versions of Call of Duty 1. (Apparently such a feature wasn't implemented in these versions). I've finished a single threaded application but it won't perform well enough for multiple servers, which is why I am trying to implement threading. Right now, each server has its own thread. I have a Networking class, which has a method; "GetStatus" -- this method is synchronized. This method uses a DatagramSocket to communicate with the server. Since this method is static and synchronized, I shouldn't get in trouble and receive a whole bunch of "Address already in use" exceptions. However, I have a second method named "SendMessage". This method is supposed to send a message to the server. How can I make sure "SendMessage" cannot be invoked when there's already a thread running in "GetStatus", and the other way around? If I make both synchronized, I will still get in trouble if Thread A is opening a socket on Port 99999 and invoking "SendMessage" while Thread B is opening a socket on the same port and invoking "GetStatus"? (Game servers are usually hosted on the same ports) I guess what I am really after is a way to make an entire class synchronized, so that only one method can be invoked and run at a time by a single thread. Hope that what I am trying to accomplish/avoid is made clear in this text. Any help is greatly appreciated.

    Read the article

  • Garbage data from serial port.

    - by sasayins
    Hi I wrote a code in Linux platform that read the data in serial port, my code below: int fd; char *rbuff=NULL; struct termios new_opt, old_opt; int ret; fd = open("/dev/ttyS0", O_RDWR | O_NOCTTY); if( fd == -1 ) { printf("Can't open file: %s\n", strerror(errno)); return -1; } tcgetattr(fd, &old_opt); new_opt.c_cflag = B115200 | CS8 | CLOCAL | CREAD; new_opt.c_iflag = IGNPAR /*| ICRNL*/; new_opt.c_oflag = 0; new_opt.c_lflag = ICANON; tcsetattr(fd, TCSANOW, &new_opt); rbuff = malloc(NBUFF); printf("reading..\n"); memset(rbuff,0x00,NBUFF); ret = read(fd, rbuff, NBUFF); printf("value:%s",rbuff); if(ret == -1) { printf("Read error:%s\n",strerror(errno)); return -1; } tcsetattr(fd, TCSANOW, &old_opt); close(fd); My problem is the code above doesn't read the first data that was transmitted, then the second transmission the data is garbage, then the third is the normal data. Did I missed a setting in the serial port? Thanks.

    Read the article

  • ftp connection problem, vsftp server, active mode

    - by Mark Szente
    I have a server that runs vsftpd to handle ftp connections. One of my users have a notebook with Total Commander and WinSCP installed. Both ftp clients fail right after the connection is established to the server and it tries to download the directory listing with the following error message: Timeout detected. Could not retrieve directory listing PORT command successful. Consider using PASV. Error listing directory '/'. The weird thing is: the notebook works perfectly ok with other ftp servers. My ftp server also works well with other clients. In fact, this user also has a pc running on the same LAN as the notebook and the pc works well with the ftp server. We use PORT ftp connection mode. Passive mode works well but is not an option at this point. I would post more technical details but I don't even know what this problem is related to. Anyway, below is the server side tcpdump for the failed connection attempt. There's no further communication between the client and the server after the last line of log. Thank you very much for any hint! 23:39:24.514852 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: S 1314489715:1314489715(0) win 65535 <mss 1460,nop,wscale 3,nop,nop,sackOK> 23:39:24.514896 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: S 2633658883:2633658883(0) ack 1314489716 win 5840 <mss 1460,nop,nop,sackOK,nop,wscale 2> 23:39:24.520842 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: . ack 1 win 62500 23:39:24.523803 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 1:21(20) ack 1 win 1460 23:39:24.546858 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 1:15(14) ack 21 win 62497 23:39:24.546902 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: . ack 15 win 1460 23:39:24.547247 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 21:55(34) ack 15 win 1460 23:39:24.762806 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: . ack 55 win 62493 23:39:30.415011 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 15:28(13) ack 55 win 62493 23:39:30.454116 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: . ack 28 win 1460 23:39:31.036283 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 55:78(23) ack 28 win 1460 23:39:31.053018 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 28:34(6) ack 78 win 62490 23:39:31.053042 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: . ack 34 win 1460 23:39:31.053268 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 78:97(19) ack 34 win 1460 23:39:31.068969 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 34:40(6) ack 97 win 62488 23:39:31.069148 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 97:112(15) ack 40 win 1460 23:39:31.069179 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 112:119(7) ack 40 win 1460 23:39:31.076981 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: . ack 119 win 62485 23:39:31.077010 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 119:177(58) ack 40 win 1460 23:39:31.114979 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 40:45(5) ack 177 win 62478 23:39:31.115164 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 177:186(9) ack 45 win 1460 23:39:31.180966 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 45:53(8) ack 186 win 62476 23:39:31.181066 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 186:216(30) ack 53 win 1460 23:39:31.213065 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 53:80(27) ack 216 win 62473 23:39:31.213180 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 216:267(51) ack 80 win 1460 23:39:31.251086 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: P 80:86(6) ack 267 win 62466 23:39:31.251498 IP 195.70.xx.xx.20 > 62.201.xx.xx.5001: S 2640780713:2640780713(0) win 5840 <mss 1460,sackOK,timestamp 2054371220 0,nop,wscale 2> 23:39:31.290979 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: . ack 86 win 1460 23:39:34.251489 IP 195.70.xx.xx.20 > 62.201.xx.xx.5001: S 2640780713:2640780713(0) win 5840 <mss 1460,sackOK,timestamp 2054374220 0,nop,wscale 2> 23:39:40.249625 IP 195.70.xx.xx.20 > 62.201.xx.xx.5001: S 2640780713:2640780713(0) win 5840 <mss 1460,sackOK,timestamp 2054380220 0,nop,wscale 2> 23:39:43.695108 IP 195.70.xx.xx.21 > 62.201.xx.xx.1057: P 2280716551:2280716588(37) ack 3838413728 win 5840 23:39:52.248791 IP 195.70.xx.xx.20 > 62.201.xx.xx.5001: S 2640780713:2640780713(0) win 5840 <mss 1460,sackOK,timestamp 2054392220 0,nop,wscale 2> 23:40:16.245159 IP 195.70.xx.xx.20 > 62.201.xx.xx.5001: S 2640780713:2640780713(0) win 5840 <mss 1460,sackOK,timestamp 2054416221 0,nop,wscale 2> 23:40:29.853685 IP 195.70.xx.xx.21 > 62.201.xx.xx.1057: FP 37:51(14) ack 1 win 5840 23:40:31.241951 IP 195.70.xx.xx.21 > 62.201.xx.xx.2241: P 267:304(37) ack 86 win 1460 23:40:31.381708 IP 62.201.xx.xx.2241 > 195.70.xx.xx.21: . ack 304 win 62462

    Read the article

  • How can I accurately determine the age of a hard drive?

    - by Todd Stout
    Yes, if it's large, heavy, and only 65 Meg in capacity, you can assume it's ancient. An RLL controller would positively indicate the drive is from antiquity. What about drives that are only 3 or 4 years old? If I know the serial number, make and model is there a public database that indicates a manufacturing date? Update: As trite as this question might seem to some, the hard drive I was looking at that precipitated this question had no obvious manufacturing date stamped on it. I realize that most do. I think the answers given are very useful to myself and others.

    Read the article

  • Jquery convert integer to string and back

    - by Richbyte
    These are the logical steps which i need render with jquery: var x is a 2 digit number(integer) derived from an input.value(); If var x is not 33 or 44 Convert this 2 digit number to string; split the string in 2 parts as number; Add these 2 values; Return var x value as this value. Else Return var x value literally as 33 or 44 whatever is the case. Thanks!

    Read the article

  • WinXP: Error 1167 -- Device (LPT1) not connected

    - by Thomas Matthews
    I am writing a program that opens LPT1 and writes a value to it. The WriteFile function is returning an error code of 1167, "The device is not connected". The Device Manager shows that LPT1 is present. I have a cable connected between a development board and the PC. The cable converts JTAG pin signals to signals on the parallel port. Power is applied and the cable is connected between the development board and the PC. The development board is powered on. I am using: Windows XP MS Visual Studio 2008, C language, console application, debug environment. Here is the relevant code fragments: HANDLE parallel_port_handle; void initializePort(void) { TCHAR * port_name = TEXT("LPT1:"); parallel_port_handle = CreateFile( port_name, GENERIC_READ | GENERIC_WRITE, 0, // must be opened with exclusive-access NULL, // default security attributes OPEN_EXISTING, // must use OPEN_EXISTING 0, // not overlapped I/O NULL // hTemplate must be NULL for comm devices ); if (parallel_port_handle == INVALID_HANDLE_VALUE) { // Handle the error. printf ("CreateFile failed with error %d.\n", GetLastError()); Pause(); exit(1); } return; } void writePort( unsigned char a_ucPins, unsigned char a_ucValue ) { DWORD dwResult; if ( a_ucValue ) { g_siIspPins = (unsigned char) (a_ucPins | g_siIspPins); } else { g_siIspPins = (unsigned char) (~a_ucPins & g_siIspPins); } /* This is a sample code for Windows/DOS without Windows Driver. */ // _outp( g_usOutPort, g_siIspPins ); //---------------------------------------------------------------------- // For Windows XP and later //---------------------------------------------------------------------- if(!WriteFile (parallel_port_handle, &g_siIspPins, 1, &dwResult, NULL)) { printf("Could not write to LPT1 (error %d)\n", GetLastError()); Pause(); return; } } If you believe this should be posted on Stack Overflow, please migrate it over (thanks).

    Read the article

  • NetBSD Networking

    - by Mike
    Hello, everyone! I have an old Toshiba Satellite 4015CDT, with Pentium II MMX, 32MB RAM, 4GB HDD. It also has one USB 1.0 port, parallel and serial ports, a 3.5" floppy drive and a CD-ROM drive (probably almost dead). I've installed NetBSD on this machine (full install) and now I want to connect it to the Internet. Although it has one PCMCIA modem card in it, it is obviously not an option. I've narrowed down my available options to the following: Connect a USB wireless adapter. I have a Realtek RTL8192 adapter, but although the system gives me the device's name (through dmesg) it fails to recognize it as a network adapter. Connect the laptop to another machine through a serial connection, so that the other machine will serve as a bridge to the Internet. Here is the page from the NetBSD documentation on serial connections. Unfortunately, I was not able to find anything on bridging there. I would very much appreciate your suggestions on the topic. Thanks in advance.

    Read the article

  • Easiest way to allow direct HTTPS connection in Intercept mode?

    - by Nick Lin
    I know the SSL issue has been beaten to death I'm using DNS redirect to force my clients to use my intercept proxy. As we all know, intercepting HTTPS connection is not possible unless I provide a fake certificate. What I want to achieve here is to allow all HTTPS requests connect directly to the source server, thus bypassing Squid: HTTP connection Proxy by Squid HTTPS connection Bypass Squid and connect directly I spent the past few days goolging and trying different methods but none worked so far. I read about SSL tunneling using the CONNECT method but couldn't find any more information on it. I tried a similar method in using RINETD to forward all traffic going through port 443 of my Squid back to the original IP of www.pandora.com. Unfortunately, I did not realize all other HTTPS requests are also forwarded to the IP of www.pandora.com. For example, https://www.gmail.com also takes me to https://www.pandora.com Since I'm running the Intercept mode, the forwarding needs to be dynamic and match each HTTPS domain name with proper original IP. Can this be done in Squid or iptables? Lastly, I'm directing traffic to my Squid server using DNS zone redirect. For example, a client requests www.google.com, my DNS server directs that request to my Squid IP, then my transparent Squid will proxy that request. Will this set up affect what I'm trying to achieve? I tried many methods but couldn't get it to work. Any takes on how to do this?

    Read the article

  • Cassandra Remote Connection

    - by Lyuben Todorov
    I'm not managing to connect to cassandra from outside machines. The database is hosted on a windows machine and im trying to connect through a mac (but this shouldn't cause problems) Local connection works: C:\cassandra\bin>cassandra-cli Starting Cassandra Client Connected to: "Test Cluster" on 127.0.0.1/9160 Welcome to Cassandra CLI version 1.1.6 But fails from other machines on the same network bin/cassandra-cli --host 192.168.0.10 --port 9160 org.apache.thrift.transport.TTransportException: java.net.ConnectException: Operation timed out at org.apache.thrift.transport.TSocket.open(TSocket.java:183) at org.apache.thrift.transport.TFramedTransport.open(TFramedTransport.java:81) at org.apache.cassandra.cli.CliMain.connect(CliMain.java:70) at org.apache.cassandra.cli.CliMain.main(CliMain.java:246) Exception connecting to 192.168.0.10/9160. Reason: Operation timed out. Welcome to Cassandra CLI version 1.2.0-beta3 Type 'help;' or '?' for help. Type 'quit;' or 'exit;' to quit. There is a router on the network but these ports have been triggred Ports: 1024, 7000, 7001, 7199, 9160 And the same ports were forwarded to 192.168.0.10 (where Cassandra is hosted) Cassandra version is 1.0.7 And the settings I think i need to change in cassandra.yaml listen_address: 192.168.0.10 rpc_address: I'm not really sure if I've missed any steps. Any help would be appreciated.

    Read the article

  • LAN->LAN IP translation (for TortoiseSVN + Artifacts + Buffalo router)

    - by Armchair Bronco
    Here's my scenario: I've got a VisualSVN server on my main dev box @ home. I'm also using Visual Studio 2010, TortoiseSVN, VisualSVN client (for source control), and Versioned 'Artifacts' (for bug tracking). (I had to modify the fake URL's below to use only one slash because as a new user, I can't post more than one real URL.) I've got my Buffalo AirStation WHR-HP-G300N router properly configured so my business partner can connect to the SVN server. I have port forwarding enabled for the internet-side IP address (like http:/99.888.77.66:443) which gets forwarded to an internal IP (like 192.168.11.6). This part is working great. The problem I'm having is with the integration piece between TortoiseSVN and my bug tracking system. I need to provide a bugtraq:url property, but I haven't been able to get relative paths to work. So I'm forced to use an absolute URL. On my end, I need to use the name of my server (for example: bugtraq:url = https:/my-server/svn/bla..), but this doesn't work for my partner. He needs to specify the IP address (for example: bugtraq:url = https:/999.888.77.66:443/svn/bla...) Is there a way to configure my router such that the IP address for this parameter gets re-routed/re-mapped to "https://my-server" if the request originates from the LAN itself? My router's software supports LAN-Internet and Internet-LAN, but I don't see LAN-LAN.

    Read the article

  • Trying to Set Up SSH Tunneling To MySQL Server for MySQL Query Browser

    - by Teno
    I'm trying to set up SSH tunneling on a remote web server to another MySQL server so that the database can be browsed easily with MySQL Query Browser. I'm following this page but cannot connect to the MySQL server. http://www.howtogeek.com/howto/ubuntu/access-your-mysql-server-remotely-over-ssh/ What I've done: logged in to the web server with Putty via SSH. typed ssh -L 33060:[database]:3306 [myusername]@[webserver_address] where [...]s are altered by the actual information. I was asked a password and typed it and got the following message. So it seems login was successful. socket: Protocol not supported Last login: .... 2012 from .... Copyright (c) 1980, 1983, 1986, 1988, 1990, 1991, 1993, 1994 The Regents of the University of California. All rights reserved. FreeBSD 7.1-RELEASE.... Welcome to FreeBSD! Opened MySQL Query Browser in Windows and entered Server Host: localhost Port: 33060 UserName: myusername PassWord: mypassword And it says, Could not connect to the specified instance. MySQL Error Number 2003 Can't connect to MySQL Server on 'localhost' (10061) Sorry if this is too basic. Thanks for your information.

    Read the article

  • Apache2 - Hosting two sites on the same domain with different ports

    - by user1026361
    I am hosting a staging site (test.mydomain.com) which currently work well on port 80 for two sites (test.mydomain.com and test.FRmydomain.com) I am working on a new backend and I would like to deploy a third site on this server for testing. My hope is that it will live at test.mydomain.com:4204. I've got some experience with apache and quickly added statements: Listen 4204 NameVirtualHost *:4204 and created a new config for my site. What I imagine are the relevant parts of my config: <VirtualHost *:4204 > ServerAdmin [email protected] ServerName test.mydomain.com:4204 However, the site is not publicly available, by name or ip. If i curl localhost:4204 from the server, I get the expected page content At this point, I'm a bit of a loss on how to go forwards. It seems like my config is correct but not available to be served. Am I better off defining a proxy definition so that, for instance: test.mydomain.com/4204 proxies to my localhost server or is there a way to make the site available via the internet? EDIT: I have added an iptable rule after further Googling with the command: iptables -I INPUT -p tcp --dport 4204 -j ACCEPT I can see apache listening on 4204 and the rule is definitely in place but cant reach the site

    Read the article

  • pfSense Load Balancer and Virtual IP

    - by jshin47
    I have two identical web servers on 10.2.1.13 and 10.2.1.113. I would like to set up pfSense load balancer to balance requests to both of these. I set up pools that included HTTP and HTTPS for both of these hosts, then set up virtual servers that responded on HTTP and HTTPS and referred traffic to its respective pool. However, I set up the virtual server to listen on 10.2.1.213, a LAN IP rather than a WAN IP, because I want LAN traffic to be able use the load balancer virtual server as well. So, I set up a Virtual IP for 10.2.1.213 on LAN IP, and a NAT port forwarding rule for HTTP and HTTPS traffic on a WAN IP to forward to 10.2.1.213. It seems like this should work, but it fails. What eventually happens is that when I try to access the page from WAN, I am directed to the login page for my pfSense device rather than the page I am expecting. When I try to access 10.2.1.213 from LAN, the request times out. What is going wrong here? I have tried it with and without NAT reflection to no avail. Please advise

    Read the article

  • ports only available from the outside network

    - by ChrisJ
    This is a counter-intuitive problem for me. I have a new Win 2003 server on a static IP address w.x.y.z. Tomcat 7, PostgreSQL 9.1, and Subversion are installed. All of it appears to be working fine from the server itself. We can also access the Tomcat manager, web applications, and run "svn ls svn://w.x.y.z/" from outside our network. However, when I try from another machine in the office, phpPgAdmin and svn cannot establish connections with the server. http://w.x.y.z:5432/phppgadmin cannot connect. The svn command from above returns: svn: E730061: Unable to connect to a repository at URL 'svn://w.x.y.z/' svn: E730061: Can't connect to host 'w.x.y.z': No connection could be made because the target machine actively refused it. Tomcat manager and the other web apps we have deployed work fine. Netstat -a from the server shows this: Proto Local Address Foreign Address State TCP SERVERNAME:3690 SERVERNAME:0 LISTENING TCP SERVERNAME:5432 SERVERNAME:0 LISTENING Windows Firewall was off, but just in case I also tried to enable it and open ports 3690 (svn) and 5432 (postgres). No change. I don't have access to the router/switch because it just doesn't work that way in Port-au-Prince and our sysadmin is on R&R. Is there anything that might be causing the problem from the server side?

    Read the article

  • XP box with 3 NICs on Server 2003 Domain

    - by Hannibal
    I have assigned all three NICs IP addresses that are outside the DHCP pool. I have 2 NICs are connected to 1 switch and the 3rd to my second switch. I want to assign one of the two NICs on the 1st switch to "normal" network activity (e.g. internet access, RDP, etc.) The other two NICs I want to reserve for mirroring ports on their respective switches. While this machine is connected to the domain I can access the internet and Remote Desktop. I have no idea which NIC I am using until I start mirroring a port, at which time, if I happen to be connected through one of the NICs I have dedicated to mirroring, I lose my remote desktop. I am aware that I would have more control over the NICs using Linux. I want to explore Windows solutions before I go that route because reinstalling another OS would be inconvenient (but not impossible). I would likely use a version of Backtrack (3 or 4 not sure). I would also have to learn how to access the machine remotely but I've done it before so this would be a minor obstacle. Thank you for your assistance.

    Read the article

  • Easiest way to allow direct HTTPS connection in Intercept mode?

    - by Nicolo
    I know the SSL issue has been beaten to death I'm using DNS redirect to force my clients to use my intercept proxy. As we all know, intercepting HTTPS connection is not possible unless I provide a fake certificate. What I want to achieve here is to allow all HTTPS requests connect directly to the source server, thus bypassing Squid: HTTP connection Proxy by Squid HTTPS connection Bypass Squid and connect directly I spent the past few days goolging and trying different methods but none worked so far. I read about SSL tunneling using the CONNECT method but couldn't find any more information on it. I tried a similar method in using RINETD to forward all traffic going through port 443 of my Squid back to the original IP of www.pandora.com. Unfortunately, I did not realize all other HTTPS requests are also forwarded to the IP of www.pandora.com. For example, https://www.gmail.com also takes me to https://www.pandora.com Since I'm running the Intercept mode, the forwarding needs to be dynamic and match each HTTPS domain name with proper original IP. Can this be done in Squid or iptables? Lastly, I'm directing traffic to my Squid server using DNS zone redirect. For example, a client requests www.google.com, my DNS server directs that request to my Squid IP, then my transparent Squid will proxy that request. Will this set up affect what I'm trying to achieve? I tried many methods but couldn't get it to work. Any takes on how to do this?

    Read the article

  • USB-to-Serial showing gibberish at 115200 Baud

    - by Mose
    I've got a serious problem which drives me crazy because I tried everything I could think of. First of all, I made a video: http://youtu.be/boghkuq7L_s but please read the following text for more information, not only view the video! When using a USB-to-Serial interface everything works as long as I don't go beyond 57600 Baud. At higher rates I only get giberish like this: év.­b0JNLYÆÿ¿iëd0U²(kßÞb! ú]/xscB!ï¯!BoXûÿ1ïâÖCÿ6ÌAnè*íÌC)º¿BíÞØ.C.@ÆÃwHJÂs "YE:ñ.èFðÌCÊ÷ÞÄ !x H w6@BtbHJ ̪ Ì6ì H¾a¿bH.">îvy®;f<ßBÌ p­L¨fæH­E ­þ¼MBÞI What makes the problem so strange is, I exchanged every component and the problem still presists. I tried differtent OSes (Ubuntu, WinXP, Win7, OSX 10.7) with 32 and 64 Bit. I tried USB-to-Serial interface from FTDI and Prolific. I tried reading the output from my Raspberry PI and from an Asterisk Appliance. I changed the cables and the wiring. Nothing helped. In the video I made a example with a old Notebook with native COM and put the USB-to-Serial to the same connection as "sniffer" (only Rx and GND connected) to make sure the output and everything is ok as one can see on the native port. The voltage is ok. Settings for both are 115200 Baud, 8 Bit with 1 Stop and no flow control. Native is ok. USB is messed up. I used the newest drivers and double checked all connections. I have no idea what is wrong here. As I couldn't find anyone describing problems like this I question my long experiance in computer science and think I'm doing some completly wrong... Please help :-/

    Read the article

  • USB 3.0 ports backwards compatibility problems with 2.0 devices?

    - by AaronLS
    I see some info on the net that suggest that I should be able to get my USB 2.0 devices to work in 3.0 ports. I only have two 2.0 ports on my new computer, and six 3.0 ports. I have installed drives. There's two different drivers, I guess some of the ports are supported by the intel board and some supported by some other chipset on the motherboard. I however have yet to get any of the 3.0 ports to work, and my brother had had the same issue with his devices not working in 3.0 ports on his computer. So I am beginning to wonder if the backwards compatibility isn't reliable for some reason. Maybe manufacturers opting not to implement 2.0 support on the 3.0 ports. I understand that physically the wiring is there, but that is only half the story. Beyond my brother's and my own computers (different motherboards/everything), I have yet to see a 2.0 device work in a 3.0 port. Is there any reason for this apparent device incompatibility? I.e. looking for responses that would indicate what areas to explore for issues or if there is any known cases of manufacturers deviating from spec in hardware or drivers. I am aware it's "supposed" to work :) Update: Does this have any relation to "USB Legacy Support" options in the BIOS? There several options combinations of options with "USB Legacy Support" and "USB 3.0 Legacy Support" and the description for these is a bit confusing, sounds like a bad translation.

    Read the article

  • Indefinite loops where the first time is different

    - by George T
    This isn't a serious problem or anything someone has asked me to do, just a seemingly simple thing that I came up with as a mental exercise but has stumped me and which I feel that I should know the answer to already. There may be a duplicate but I didn't manage to find one. Suppose that someone asked you to write a piece of code that asks the user to enter a number and, every time the number they entered is not zero, says "Error" and asks again. When they enter zero it stops. In other words, the code keeps asking for a number and repeats until zero is entered. In each iteration except the first one it also prints "Error". The simplest way I can think of to do that would be something like the folloing pseudocode: int number = 0; do { if(number != 0) { print("Error"); } print("Enter number"); number = getInput(); }while(number != 0); While that does what it's supposed to, I personally don't like that there's repeating code (you test number != 0 twice) -something that should generally be avoided. One way to avoid this would be something like this: int number = 0; while(true) { print("Enter number"); number = getInput(); if(number == 0) { break; } else { print("Error"); } } But what I don't like in this one is "while(true)", another thing to avoid. The only other way I can think of includes one more thing to avoid: labels and gotos: int number = 0; goto question; error: print("Error"); question: print("Enter number"); number = getInput(); if(number != 0) { goto error; } Another solution would be to have an extra variable to test whether you should say "Error" or not but this is wasted memory. Is there a way to do this without doing something that's generally thought of as a bad practice (repeating code, a theoretically endless loop or the use of goto)? I understand that something like this would never be complex enough that the first way would be a problem (you'd generally call a function to validate input) but I'm curious to know if there's a way I haven't thought of.

    Read the article

  • How do I configure the number of worker threads used by SqlServer 2005 Agent

    - by Decker
    How can I increase the limit of worker threads from the default 10 for SQL Server 2005 SqlAgent? I have 9 jobs that run almost continuously and that leaves only one available thread for the rest of the scheduled jobs. Oftentimes, when no thread is available, I will see the jobs in "Waiting for worker thread" state. I'd like to increase the number to about 12 (which should do the trick for me). Any idea where this is set?

    Read the article

  • Number of Splitters on Coaxial Connection and Cable Internet Quality of Service

    - by Matthew Ruston
    Does running multiple coaxial splitters on a single coaxial cable line effect quality of service for cable internet connections? Suppose there are 2-4 splitters between the cable line coming into a building before the connection to a cable modem, does this negatively effect the latency, throughput, etc of a cable internet connection by any measurable amount? Is there a maximum number of times that a coaxial cable can be split into multiple internet and TV connections before QoS suffers?