Search Results

Search found 409 results on 17 pages for 'corp hicks'.

Page 7/17 | < Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >

  • Wireless broken after latest 12.04 update

    - by inderpaldeol
    I updated 12.04 yesterday and it broke my wireless connection. iwconfig lo no wireless extensions. eth0 no wireless extensions. l@ubuntu:~$ lspci|grep Network 03:00.0 Network controller: Ralink corp. RT3090 Wireless 802.11n 1T/1R PCIe In the hardware drivers, I see - rt3090sta is activated but currently not in use. WICD does not show wireless networks. Can someone help me please? Thanks id

    Read the article

  • Should I reply this email? [closed]

    - by y26jin
    As a university student with 4 month internship experience in telecommunication corp before,I received one email from one of the mobile & wireless related company saying I have met all sorts of pre-selection requirements and my resume has been proceeded to the hiring manager in charge of this position.I am interested in this position and I was wondering if I should reply this email now...any thoughts or suggestions?

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • Error getting PAM / Linux integrated with Active Directory

    - by topper
    I'm trying to add a Linux server to a network which is controlled by AD. The aim is that users of the server will be able to authenticate against the AD domain. I have Kerberos working, but NSS / PAM are more problematic. I'm trying to debug with a simple command such as the following, please see the error. Can anyone assist me to debug? root@antonyg04:~# ldapsearch -H ldap://raadc04.corp.MUNGED.com/ -x -D "cn=MUNGED,ou=Users,dc=corp,dc=MUNGED,dc=com" -W uid=MUNGED Enter LDAP Password: ldap_bind: Invalid credentials (49) additional info: 80090308: LdapErr: DSID-0C090334, comment: AcceptSecurityContext error, data 525, vece I have had to munge some details, but I can tell you that cn=MUNGED is my username for logging into the AD domain, and the password that I typed was the password for said domain. I don't know why it says "Invalid credentials", and the rest of the error is so cryptic, I have no idea. Is my approach somehow flawed? Is my DN obviously wrong? How can I confirm the correct DN? There was a tool online but I can't find it. NB I have no access to the AD Server for administration or configuration.

    Read the article

  • Using AuthzSVNAccessFile for controlling SVN Access produces HTTP 400 Bad Request

    - by meeper
    I have a new repository on an existing subversion server that requires us to perform path based authorization within the repository. I found that the AuthzSVNAccessFile directive in apache is directly responsible for allowing this functionality. After fixing several other problems such as AuthzSVNAccessFile preventing SVNListParentPath from operating properly, I am left with one single problem. I can checkout, I can update, I can commit, BUT I cannot execute an SVN COPY for performing branch/tagging operations. The moment I comment out the AuthzSVNAccessFile line in the Apache config everything works as expected except the obvious path authorizations. Versions: The server OS is Debian 6.0.7 (Squeeze) Apache 2.2.16-6+squeeze11 Server Subversion 1.6.12dfsg-7 Clients are running windows Clients tried are: TortoiseSVN 1.8.2 Build 24708 64bit SVN CLI Client 1.8.3 (r1516576) Authentication is performed via AD to a Windows 2003 domain and appears to be operating normally. I have stripped out all other configurations and repository setups to produce this single configuration that reproduces the problem. Apache Configuration: <VirtualHost *:443> ServerName svn-test.company.com ServerAlias /svn-test ServerAdmin [email protected] SSLEngine On SSLCertificateFile /etc/apache2/apache.pem ErrorLog /var/log/apache2/svn-test_error.log LogLevel warn CustomLog /var/log/apache2/svn-test_access.log combined ServerSignature On # Repository Access to all Repositories <Location "/"> DAV svn SVNParentPath /var/svn SVNListParentPath on AuthBasicProvider ldap AuthType Basic AuthzLDAPAuthoritative Off AuthName "Subversion Test Repository System" AuthLDAPURL "ldap://adserver.company.com:389/DC=corp,DC=company,DC=com?sAMAccountName?sub?(objectClass=*)" NONE AuthLDAPBindDN "CN=service_account,OU=ServiceIDs,OU=corp,OU=Delegated,DC=na,DC=corp,DC=company,DC=com" AuthLDAPBindPassword service_account_password Require valid-user SSLRequireSSL </Location> # <LocationMatch /.+> is a really dirty trick to make listing of repositories work # http://d.hatena.ne.jp/shimonoakio/20080130/1201686016 <LocationMatch /.+> AuthzSVNAccessFile /etc/apache2/svn_path_auth </LocationMatch> </VirtualHost> SVN Access File: [/] * = rw The repository used (AuthTestBasic) consists of the following directory structure and contains no externals (this is a literal listing, not an example): / /branches/ /tags/ /trunk/ /trunk/somefile.txt Tortoise produces the following error during a tag operation in it's tag result window: Adding directory failed: COPY on /authtestbasic/!svn/bc/2/trunk (400 Bad Request) The svn.exe CLI client produces the following error: C:\Users\e20epkt>svn copy https://servername/authtestbasic/trunk https://servername/authtestbasic/tags/tag1 -m "svn cli client" svn: E175002: Adding directory failed: COPY on /authtestbasic/!svn/bc/2/trunk (400 Bad Request) The Apache error log has nothing in it, however the apache access log has the following in it (IP addresses and usernames changed obviously): 10.1.2.100 - - [17/Oct/2013:11:53:40 -0700] "OPTIONS /authtestbasic/trunk HTTP/1.1" 401 2595 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "OPTIONS /authtestbasic/trunk HTTP/1.1" 200 996 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "OPTIONS /authtestbasic/trunk HTTP/1.1" 200 884 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPFIND /authtestbasic/trunk HTTP/1.1" 207 692 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPFIND /authtestbasic/!svn/vcc/default HTTP/1.1" 207 596 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "REPORT /authtestbasic/!svn/bc/0/trunk HTTP/1.1" 404 580 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPFIND /authtestbasic/!svn/vcc/default HTTP/1.1" 207 596 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "REPORT /authtestbasic/!svn/bc/2/trunk HTTP/1.1" 200 674 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPFIND /authtestbasic/!svn/bc/2/trunk HTTP/1.1" 207 548 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPFIND /authtestbasic/tags/tag1 HTTP/1.1" 404 580 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "MKACTIVITY /authtestbasic/!svn/act/f1e9dc07-fb5e-5a41-ac22-907705ef6e5e HTTP/1.1" 201 708 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPFIND /authtestbasic/tags HTTP/1.1" 207 580 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "CHECKOUT /authtestbasic/!svn/vcc/default HTTP/1.1" 201 708 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "PROPPATCH /authtestbasic/!svn/wbl/f1e9dc07-fb5e-5a41-ac22-907705ef6e5e/2 HTTP/1.1" 207 596 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "CHECKOUT /authtestbasic/!svn/ver/1/tags HTTP/1.1" 201 724 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "COPY /authtestbasic/!svn/bc/2/trunk HTTP/1.1" 400 596 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" 10.1.2.100 - myuseraccount [17/Oct/2013:11:53:40 -0700] "DELETE /authtestbasic/!svn/act/f1e9dc07-fb5e-5a41-ac22-907705ef6e5e HTTP/1.1" 204 1956 "-" "SVN/1.8.3 (x64-microsoft-windows) serf/1.3.1 TortoiseSVN-1.8.2.24708" You'll see that the second to last line contains the COPY command with the HTTP 400 response, however, there doesn't appear to be any indication as to why. Please note that, while yes this is a test repository on a test server, I am experiencing this same issue in this test setup where I have eliminated all other possible causes (mixed repository configurations, externals, etc). I have also confirmed that all files for the repository (/var/svn/authtestbasic) are owned by the Apache user www-data.

    Read the article

  • Using MS Standalone profiler in VS2008 Professional

    - by fishdump
    I am trying to profile my .NET dll while running it from VS unit testing tools but I am having problems. I am using the standalone command-line profiler as VS2008 Professional does not come with an inbuilt profiler. I have an open CMD window and have run the following commands (I instrumented it earlier which is why vsinstr gave the warning that it did): C:\...\BusinessRules\obj\Debug>vsperfclrenv /samplegclife /tracegclife /globalsamplegclife /globaltracegclife Enabling VSPerf Sampling Attach Profiling. Allows to 'attaching' to managed applications. Current Profiling Environment variables are: COR_ENABLE_PROFILING=1 COR_PROFILER={0a56a683-003a-41a1-a0ac-0f94c4913c48} COR_LINE_PROFILING=1 COR_GC_PROFILING=2 C:\...\BusinessRules\obj\Debug>vsinstr BusinessRules.dll Microsoft (R) VSInstr Post-Link Instrumentation 9.0.30729 x86 Copyright (C) Microsoft Corp. All rights reserved. Error VSP1018 : VSInstr does not support processing binaries that are already instrumented. C:\...\BusinessRules\obj\Debug>vsperfcmd /start:trace /output:foo.vsp Microsoft (R) VSPerf Command Version 9.0.30729 x86 Copyright (C) Microsoft Corp. All rights reserved. C:\...\BusinessRules\obj\Debug> I then ran the unit tests that exercised the instrumented code. When the unit tests were complete, I did... C:\...\BusinessRules\obj\Debug>vsperfcmd /shutdown Microsoft (R) VSPerf Command Version 9.0.30729 x86 Copyright (C) Microsoft Corp. All rights reserved. Waiting for process 4836 ( C:\Program Files\Microsoft Visual Studio 9.0\Common7\IDE\vstesthost.exe) to shutdown... It was clearly waiting for VS2008 to close so I closed it... Shutting down the Profile Monitor ------------------------------------------------------------ C:\...\BusinessRules\obj\Debug> All looking good, there was a 3.2mb foo.vsp file in the directory. I next did... C:\...\BusinessRules\obj\Debug>vsperfreport foo.vsp /summary:all Microsoft (R) VSPerf Report Generator, Version 9.0.0.0 Copyright (C) Microsoft Corporation. All rights reserved. VSP2340: Environment variables were not properly set during profiling run and managed symbols may not resolve. Please use vsperfclrenv before profiling. File opened Successfully opened the file. A report file, foo_Header.csv, has been generated. A report file, foo_MarksSummary.csv, has been generated. A report file, foo_ProcessSummary.csv, has been generated. A report file, foo_ThreadSummary.csv, has been generated. Analysis completed A report file, foo_FunctionSummary.csv, has been generated. A report file, foo_CallerCalleeSummary.csv, has been generated. A report file, foo_CallTreeSummary.csv, has been generated. A report file, foo_ModuleSummary.csv, has been generated. C:\...\BusinessRules\obj\Debug> Notice the warning about environment variables and using vsperfclrenv? But I had run it! Maybe I used the wrong switches? I don't know. Anyway, loading the csv files into Excel or using the perfconsole tool gives loads of useful info with useless symbol names: *** Loading commands from: C:\temp\PerfConsole\bin\commands\timebytype.dll *** Adding command: timebytype *** Loading commands from: C:\temp\PerfConsole\bin\commands\partition.dll *** Adding command: partition Welcome to PerfConsole 1.0 (for bugs please email: [email protected]), for help type: ?, for a quickstart type: ?? > load foo.vsp *** Couldn't match to either expected sampled or instrumented profile schema, defaulting to sampled *** Couldn't match to either expected sampled or instrumented profile schema, defaulting to sampled *** Profile loaded from 'foo.vsp' into @foo > > functions @foo >>>>> Function Name Exclusive Inclusive Function Name Module Name -------------------- -------------------- -------------- --------------- 900,798,600,000.00 % 900,798,600,000.00 % 0x0600003F 20397910 14,968,500,000.00 % 44,691,540,000.00 % 0x06000040 14736385 8,101,253,000.00 % 14,836,330,000.00 % 0x06000041 5491345 3,216,315,000.00 % 6,876,929,000.00 % 0x06000042 3924533 <snip> 71,449,430.00 % 71,449,430.00 % 0x0A000074 42572 52,914,200.00 % 52,914,200.00 % 0x0A000073 0 14,791.00 % 13,006,010.00 % 0x0A00007B 0 199,177.00 % 6,082,932.00 % 0x2B000001 5350072 2,420,116.00 % 2,420,116.00 % 0x0A00008A 0 836.00 % 451,888.00 % 0x0A000045 0 9,616.00 % 399,436.00 % 0x0A000039 0 18,202.00 % 298,223.00 % 0x06000046 1479900 I am so close to being able to find the bottlenecks, if only it will give me the function and module names instead of hex numbers! What am I doing wrong? --- Alistair.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • PowerShell PowerPack Download

    - by BuckWoody
    I read Jeffery Hicks’ article in this month’s Redmond Magazine on a new add-in for Windows PowerShell 2.0. It’s called the PowerShell Pack and it has a some great new features that I plan to put into place on my production systems as soon as I finished learning and testing them. You can download the pack here if you have PowerShell 2.0. I’m having a lot of fun with it, and I’ll blog about what I’m learning here in the near future, but you should check it out. The only issue I have with it right now is that you have to load a module and then use get-help to find out what it does, because I haven’t found a lot of other documentation so far. The most interesting modules for me are the ones that can run a command elevated (in PSUserTools), the task scheduling commands (in TaskScheduler) and the file system checks and tools (in FileSystem). There’s also a way to create simple Graphical User Interface panels (in ). I plan to string all these together to install a management set of tools on my SQL Server Express Instances, giving the user “task buttons” to backup or restore a database, add or delete users and so on. Yes, I’ll be careful, and yes, I’ll make sure the user is allowed to do that. For now, I’m testing the download, but I thought I would share what I’m up to. If you have PowerShell 2.0 and you download the pack, let me know how you use it. Script Disclaimer, for people who need to be told this sort of thing: Never trust any script, including those that you find here, until you understand exactly what it does and how it will act on your systems. Always check the script on a test system or Virtual Machine, not a production system. Yes, there are always multiple ways to do things, and this script may not work in every situation, for everything. It’s just a script, people. All scripts on this site are performed by a professional stunt driver on a closed course. Your mileage may vary. Void where prohibited. Offer good for a limited time only. Keep out of reach of small children. Do not operate heavy machinery while using this script. If you experience blurry vision, indigestion or diarrhea during the operation of this script, see a physician immediately. Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • Slow wifi on Ubuntu 12.04 wifi driver ath9k

    - by lunar
    For the last couple of days my wifi connection is extremely slow. I am pretty sure that it is caused by the driver. Can this be improved? lo no wireless extensions. wlan0 IEEE 802.11bgn ESSID:"MyWiFi" Mode:Managed Frequency:2.437 GHz Access Point: 00:18:68:FE:7B:C7 Bit Rate=58.5 Mb/s Tx-Power=15 dBm Retry long limit:7 RTS thr:off Fragment thr:off Power Management:off Link Quality=48/70 Signal level=-62 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:6960 Missed beacon:0 eth0 no wireless extensions. sudo lshw -class network *-network description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:03:00.0 logical name: wlan0 version: 01 serial: 74:f0:6d:34:c2:4e width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.2.0-31-generic-pae firmware=N/A ip=192.168.1.2 latency=0 link=yes multicast=yes wireless=IEEE 802.11bgn resources: irq:17 memory:d7400000-d740ffff *-network description: Ethernet interface product: AR8131 Gigabit Ethernet vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:06:00.0 logical name: eth0 version: c0 serial: 48:4b:38:78:f6:ae capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI firmware=N/A latency=0 link=no multicast=yes port=twisted pair resources: irq:51 memory:d3800000-d383ffff ioport:8000(size=128) lsusb Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 003: ID 04f2:b1bb Chicony Electronics Co., Ltd Bus 001 Device 004: ID 0b05:1788 ASUSTek Computer, Inc. lspci 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 18) 00:01.0 PCI bridge: Intel Corporation Core Processor PCI Express x16 Root Port (rev 18) 00:02.0 VGA compatible controller: Intel Corporation Core Processor Integrated Graphics Controller (rev 18) 00:16.0 Communication controller: Intel Corporation 5 Series/3400 Series Chipset HECI Controller (rev 06) 00:1a.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.1 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 2 (rev 06) 00:1c.3 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 4 (rev 06) 00:1c.4 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 5 (rev 06) 00:1c.5 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 6 (rev 06) 00:1d.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation Mobile 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 4 port SATA AHCI Controller (rev 06) 00:1f.6 Signal processing controller: Intel Corporation 5 Series/3400 Series Chipset Thermal Subsystem (rev 06) 01:00.0 VGA compatible controller: NVIDIA Corporation GF108 [GeForce GT 425M] (rev a1) 03:00.0 Network controller: Atheros Communications Inc. AR9285 Wireless Network Adapter (PCI-Express) (rev 01) 04:00.0 USB controller: Fresco Logic Device 1400 (rev 01) 06:00.0 Ethernet controller: Atheros Communications Inc. AR8131 Gigabit Ethernet (rev c0) ff:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 05) ff:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 05) ff:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 05) ff:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 05) ff:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 05) ff:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 05) rfkill list all 0: hci0: Bluetooth Soft blocked: yes Hard blocked: no 1: phy0: Wireless LAN Soft blocked: no Hard blocked: no

    Read the article

  • ALC889 - GA-P55-UD4 -no sound - Ubuntu 11.10

    - by george
    I have computer with a Gigabyte P55A-UD4 motherboard. I have on-board audio - Realtek ALC889. I am using Ubuntu 11.10 and have no sound. please please heeeelp :). i have tryed to install high definition audio codecs from realtek but it doesn't work. in bios the azalia codec is turned on. ps : sorry for my english. 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 12) 00:01.0 PCI bridge: Intel Corporation Core Processor PCI Express x16 Root Port (rev 12) 00:1a.0 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1a.1 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1a.2 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1a.7 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.4 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 5 (rev 06) 00:1c.5 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 6 (rev 06) 00:1c.6 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 7 (rev 06) 00:1d.0 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1d.1 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1d.2 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1d.3 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB Universal Host Controller (rev 06) 00:1d.7 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 6 port SATA AHCI Controller (rev 06) 00:1f.3 SMBus: Intel Corporation 5 Series/3400 Series Chipset SMBus Controller (rev 06) 01:00.0 VGA compatible controller: nVidia Corporation GT216 [GeForce GT 220] (rev a2) 01:00.1 Audio device: nVidia Corporation High Definition Audio Controller (rev a1) 03:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 03:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 04:00.0 IDE interface: Marvell Technology Group Ltd. Device 91a3 (rev 11) 05:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 06:03.0 IDE interface: Integrated Technology Express, Inc. IT8213 IDE Controller 06:07.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link) 3f:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 02) 3f:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 02) 3f:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 02) 3f:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 02) 3f:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 02) 3f:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 02) aplay -l karta 0: Intel [HDA Intel], urzadzenie 0: ALC889 Analog [ALC889 Analog] Urzadzenia podrzedne: 1/1 Urzadzenie podrzedne #0: subdevice #0 karta 0: Intel [HDA Intel], urzadzenie 1: ALC889 Digital [ALC889 Digital] Urzadzenia podrzedne: 1/1 Urzadzenie podrzedne #0: subdevice #0 karta 1: NVidia [HDA NVidia], urzadzenie 3: HDMI 0 [HDMI 0] Urzadzenia podrzedne: 1/1 Urzadzenie podrzedne #0: subdevice #0 karta 1: NVidia [HDA NVidia], urzadzenie 7: HDMI 0 [HDMI 0] Urzadzenia podrzedne: 1/1 Urzadzenie podrzedne #0: subdevice #0 karta 1: NVidia [HDA NVidia], urzadzenie 8: HDMI 0 [HDMI 0] Urzadzenia podrzedne: 1/1 Urzadzenie podrzedne #0: subdevice #0 karta 1: NVidia [HDA NVidia], urzadzenie 9: HDMI 0 [HDMI 0] Urzadzenia podrzedne: 1/1 Urzadzenie podrzedne #0: subdevice #0

    Read the article

  • How do I configure WakeOnUSB properly?

    - by wishi
    How do I configure Wake-On-USB properly on a 10.04 or 10.10 Ubuntu (2.6.36 and higher if needed)? (Wake-on-USB is when the computer is asleep and for example a USB Keyboard event wakes up the machine!) The notebook is an Acer Aspire Timeline X 1830T. I don't know in which way the Linux Kernel supports the controllers. There are different ways to approach this, for example /proc/acpi/wakeup... or UDEV... or something with HAL? /proc/acpi/wakeup shows every device in S4, but I need S3. Device S-state Status Sysfs node P0P2 S4 *disabled PEGP S4 *disabled P0P1 S0 *disabled pci:0000:00:1e.0 EHC1 S4 *disabled pci:0000:00:1d.0 USB1 S4 *enabled USB2 S4 *disabled USB3 S4 *disabled USB4 S4 *disabled EHC2 S4 *disabled pci:0000:00:1a.0 USB5 S4 *disabled USB6 S4 *disabled USB7 S4 *disabled HDEF S0 *disabled pci:0000:00:1b.0 RP01 S5 *disabled pci:0000:00:1c.0 PXSX S5 *disabled pci:0000:01:00.0 RP02 S0 *disabled pci:0000:00:1c.1 PXSX S5 *disabled pci:0000:02:00.0 RP03 S0 *disabled PXSX S5 *disabled RP04 S0 *disabled PXSX S5 *disabled RP05 S0 *disabled PXSX S5 *disabled RP07 S0 *disabled PXSX S5 *disabled RP08 S0 *disabled PXSX S5 *disabled GLAN S0 *disabled PEG3 S4 *disabled PEG5 S4 *disabled PEG6 S4 *disabled SLPB S3 *enabled S4, which is Suspend-To-Disk afaik... doesn't seem to work either if I echo USB1 into the wakeup table. It just sets an S4 flag. can I get the USB ports in S3? I want to make the machine wakeup from Suspend-To-Ram (S3, ACPI standard) in case a key on my external keyboard is pressed. It only wakes up if a key on the internal Laptop keyboard is pressed... from Suspend To Ram. It seems if I plug in a USB mouse, that the USB port isn't even powered. I have no BIOS option to change this. Further specific information regarding the device: usb-devices T: Bus=01 Lev=02 Prnt=02 Port=01 Cnt=01 Dev#= 13 Spd=1.5 MxCh= 0 D: Ver= 1.10 Cls=00(>ifc ) Sub=00 Prot=00 MxPS= 8 #Cfgs= 1 P: Vendor=04d9 ProdID=1603 Rev=03.10 S: Manufacturer= S: Product=USB Keyboard C: #Ifs= 2 Cfg#= 1 Atr=a0 MxPwr=100mA I: If#= 0 Alt= 0 #EPs= 1 Cls=03(HID ) Sub=01 Prot=01 Driver=usbhid I: If#= 1 Alt= 0 #EPs= 1 Cls=03(HID ) Sub=00 Prot=00 Driver=usbhid root@underwater-laptop:/# lsusb [...] Bus 001 Device 013: ID 04d9:1603 Holtek Semiconductor, Inc. Bus 001 Device 004: ID 0bda:0138 Realtek Semiconductor Corp. Bus 001 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub [...] If this doesn't work I have to properly explain why :( - but I think it is very hard to research this kernel internal. Any hints for good information here? I hope it's possible... I'm just looking for any solution. edit: this, waking up on USB, works on Windows! Thanks a lot, Marius

    Read the article

  • DropDownListFor and relating my lambda to my ViewModel

    - by Daniel Harvey
    After googling for a while I'm still drawing a blank here. I'm trying to use a ViewModel to pull and provide a dictionary to a drop down list inside a strongly typed View: <%@ Page Title="" Language="C#" MasterPageFile="~/Views/Shared/Site.Master" Inherits="Notebook.ViewModels.CorporationJoinViewModel" %> ... <%: Html.DropDownListFor(c => c.CorpDictionary.Keys, new SelectList(Model.CorpDictionary, "Value", "Key"))%> I'm getting the error CS1061: 'object' does not contain a definition for 'CorpDictionary' and no extension method 'CorpDictionary' accepting a first argument of type 'object' could be found and the relevant bit of my ViewModel public class CorporationJoinViewModel { DB _db = new DB(); // data context public Dictionary<int, string> CorpDictionary { get { Dictionary<int, string> corporations = new Dictionary<int, string>(); int x = 0; foreach (Corporation corp in _db.Corporations) { corporations.Add(x, corp.name); } return corporations; } } I'll admit i have a pretty magical understanding of how linq is finding my ViewModel object from that lambda, and the error message is making me think it's not. Is my problem the method I'm using to pass the data? What am I missing here?

    Read the article

  • Text piped to PowerShell.exe isn't recieved when using [Console]::ReadLine()

    - by crtracy
    I'm getting itermittent data loss when calling .NET [Console]::ReadLine() to read piped input to PowerShell.exe: >ping localhost | powershell -NonInteractive -NoProfile -C "do {$line = [Console]::ReadLine(); ('' + (Get-Date -f 'HH:mm :ss') + $line) | Write-Host; } while ($line -ne $null)" 23:56:45time<1ms 23:56:45 23:56:46time<1ms 23:56:46 23:56:47time<1ms 23:56:47 23:56:47 Normally 'ping localhost' from Vista64 looks like this, so there is a lot of data missing from the output above: Pinging WORLNTEC02.bnysecurities.corp.local [::1] from ::1 with 32 bytes of data: Reply from ::1: time<1ms Reply from ::1: time<1ms Reply from ::1: time<1ms Reply from ::1: time<1ms Ping statistics for ::1: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms But using the same API from C# recieves all the data sent to the process (excluding some newline differences). Code: namespace ConOutTime { class Program { static void Main (string[] args) { string s; while ((s = Console.ReadLine ()) != null) { if (s.Length > 0) // don't write time for empty lines Console.WriteLine("{0:HH:mm:ss} {1}", DateTime.Now, s); } } } } Output: 00:44:30 Pinging WORLNTEC02.bnysecurities.corp.local [::1] from ::1 with 32 bytes of data: 00:44:30 Reply from ::1: time<1ms 00:44:31 Reply from ::1: time<1ms 00:44:32 Reply from ::1: time<1ms 00:44:33 Reply from ::1: time<1ms 00:44:33 Ping statistics for ::1: 00:44:33 Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), 00:44:33 Approximate round trip times in milli-seconds: 00:44:33 Minimum = 0ms, Maximum = 0ms, Average = 0ms So, if calling the same API from PowerShell instead of C# many parts of StdIn get 'eaten'. Is the PowerShell host reading string from StdIn even though I didn't use 'PowerShell.exe -Command -'?

    Read the article

  • XPath Trouble with getting attributes

    - by Travis
    I'm having a bit of trouble with some XML in Java. The following is the result of an API call to EVE Online. How can I get the "name" and "characterID" for each row? Frankly I just have no idea where to start with this one, so please don't ask for extra information. I just gotta know how to get those attributes. <?xml version='1.0' encoding='UTF-8'?> <eveapi version="1"> <currentTime>2007-12-12 11:48:50</currentTime> <result> <rowset name="characters" key="characterID" columns="name,characterID,corporationName,corporationID"> <row name="Mary" characterID="150267069" corporationName="Starbase Anchoring Corp" corporationID="150279367" /> <row name="Marcus" characterID="150302299" corporationName="Marcus Corp" corporationID="150333466" /> <row name="Dieinafire" characterID="150340823" corporationName="Center for Advanced Studies" corporationID="1000169" /> </rowset> </result> <cachedUntil>2007-12-12 12:48:50</cachedUntil> </eveapi>

    Read the article

  • hyperv vss writer unexpected error

    - by Eric Martin
    I am using Mozy Pro to backup our Hyperv servers. I am doing this without any issues on a 2nd server but this box hasn't backed up sucessfully yet. I was told by the support tech at Mozy to type: vssadmin list providers >c:\providers.txt vssadmin list writers >c:\writers.txt Writers.txt: vssadmin 1.1 - Volume Shadow Copy Service administrative command-line tool (C) Copyright 2001-2013 Microsoft Corp. Writer name: 'Task Scheduler Writer' Writer Id: {d61d61c8-d73a-4eee-8cdd-f6f9786b7124} Writer Instance Id: {1bddd48e-5052-49db-9b07-b96f96727e6b} State: [1] Stable Last error: No error Writer name: 'VSS Metadata Store Writer' Writer Id: {75dfb225-e2e4-4d39-9ac9-ffaff65ddf06} Writer Instance Id: {088e7a7d-09a8-4cc6-a609-ad90e75ddc93} State: [1] Stable Last error: No error Writer name: 'Performance Counters Writer' Writer Id: {0bada1de-01a9-4625-8278-69e735f39dd2} Writer Instance Id: {f0086dda-9efc-47c5-8eb6-a944c3d09381} State: [1] Stable Last error: No error Writer name: 'System Writer' Writer Id: {e8132975-6f93-4464-a53e-1050253ae220} Writer Instance Id: {506e7d9c-ded3-4edf-824a-4dd9af7f7538} State: [1] Stable Last error: No error Writer name: 'ASR Writer' Writer Id: {be000cbe-11fe-4426-9c58-531aa6355fc4} Writer Instance Id: {1de438e4-09de-487c-9ea8-eeafbe3fd210} State: [1] Stable Last error: No error Writer name: 'COM+ REGDB Writer' Writer Id: {542da469-d3e1-473c-9f4f-7847f01fc64f} Writer Instance Id: {511d23d9-4cbb-400f-b739-e6e0a8ecdbee} State: [1] Stable Last error: No error Writer name: 'Microsoft Hyper-V VSS Writer' Writer Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Instance Id: {32f41185-2b20-41ff-a7aa-92c262f578cd} State: [1] Stable Last error: Unexpected error Writer name: 'Registry Writer' Writer Id: {afbab4a2-367d-4d15-a586-71dbb18f8485} Writer Instance Id: {fa328ece-623f-43cc-9888-e897e108c40e} State: [1] Stable Last error: No error Writer name: 'Shadow Copy Optimization Writer' Writer Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} Writer Instance Id: {7b582861-7f7f-4c10-adb1-5106bcab3902} State: [1] Stable Last error: No error Writer name: 'WMI Writer' Writer Id: {a6ad56c2-b509-4e6c-bb19-49d8f43532f0} Writer Instance Id: {d2f73a0f-c19a-44cc-bcd2-6c84ac6e516b} State: [1] Stable Last error: No error Writer name: 'MSMQ Writer (MSMQ)' Writer Id: {7e47b561-971a-46e6-96b9-696eeaa53b2a} Writer Instance Id: {95ea6efc-c00c-47ca-90d1-28fbe6d7a8d0} State: [1] Stable Last error: No error Writer name: 'IIS Config Writer' Writer Id: {2a40fd15-dfca-4aa8-a654-1f8c654603f6} Writer Instance Id: {d5a32f43-0675-400d-8502-cdece4c867e1} State: [1] Stable Last error: No error Providers.txt: vssadmin 1.1 - Volume Shadow Copy Service administrative command-line tool (C) Copyright 2001-2013 Microsoft Corp. Provider name: 'Microsoft File Share Shadow Copy provider' Provider type: Fileshare Provider Id: {89300202-3cec-4981-9171-19f59559e0f2} Version: 1.0.0.1 Provider name: 'Microsoft Software Shadow Copy provider 1.0' Provider type: System Provider Id: {b5946137-7b9f-4925-af80-51abd60b20d5} Version: 1.0.0.7 The tech said I needed to resolve this issue: Writer name: 'Microsoft Hyper-V VSS Writer' Writer Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Instance Id: {32f41185-2b20-41ff-a7aa-92c262f578cd} State: [1] Stable Last error: Unexpected error I checked the event viewer and this is the only thing I found related to hyperv: I don't know where to start to resolve this or to find out where the issue is at. I know nothing of the vss writer for hyperv so any input would be greatly appreciated.

    Read the article

  • Graphics driver for ubuntu on dell latitude XT

    - by marc.riera
    Hi, we have a laptop (dell latitude xt) on our company, and we would like to install ubuntu on it. windows 7 works fine out of the box, so the hardware is fine. since this laptop has a touchscreen we just installed ubuntu 10.10 netbook edition 32x. But, we do not manage to enable the touchscreen, neither the vga graphic drivers. this is the output from lspci, if somebody cares. 00:00.0 Host bridge: ATI Technologies Inc Radeon Xpress 7930 Host Bridge 00:01.0 PCI bridge: ATI Technologies Inc RS7932 PCI Bridge 00:04.0 PCI bridge: ATI Technologies Inc Device 7934 00:06.0 PCI bridge: ATI Technologies Inc RS7936 PCI Bridge 00:07.0 PCI bridge: ATI Technologies Inc Device 7937 00:13.0 USB Controller: ATI Technologies Inc SB600 USB (OHCI0) 00:13.1 USB Controller: ATI Technologies Inc SB600 USB (OHCI1) 00:13.2 USB Controller: ATI Technologies Inc SB600 USB (OHCI2) 00:13.3 USB Controller: ATI Technologies Inc SB600 USB (OHCI3) 00:13.4 USB Controller: ATI Technologies Inc SB600 USB (OHCI4) 00:13.5 USB Controller: ATI Technologies Inc SB600 USB Controller (EHCI) 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 14) 00:14.1 IDE interface: ATI Technologies Inc SB600 IDE 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) 00:14.3 ISA bridge: ATI Technologies Inc SB600 PCI to LPC Bridge 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge 01:05.0 VGA compatible controller: ATI Technologies Inc Radeon Xpress 1250 03:01.0 CardBus bridge: Texas Instruments PCIxx12 Cardbus Controller 03:01.1 FireWire (IEEE 1394): Texas Instruments PCIxx12 OHCI Compliant IEEE 1394 Host Controller 03:01.3 SD Host controller: Texas Instruments PCIxx12 SDA Standard Compliant SD Host Controller 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5756ME Gigabit Ethernet PCI Express 0b:00.0 Network controller: Broadcom Corporation BCM4321 802.11a/b/g/n (rev 03) I've tryied to install ati drivers 9.3 , which I downloaded and installed, unpacked and installed, builded and installed, but nothing worked. Looks like the latests version is just accepted to work on jaunty 9.04, so they are kind of old. what else I can do? thanks. Marc Information added: lsusb and lspci -n |grep 01:05.0 sysop@wl083517:~$ lspci -n |grep 01:05.0 01:05.0 0300: 1002:7942 sysop@wl083517:~$ lsusb Bus 006 Device 002: ID 413c:8138 Dell Computer Corp. Wireless 5520 Voda I Mobile Broadband (3G HSDPA) Minicard EAP-SIM Port Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 002: ID 413c:8140 Dell Computer Corp. Wireless 360 Bluetooth Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 002: ID 0483:2016 SGS Thomson Microelectronics Fingerprint Reader Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 002: ID 1b96:0001 N-Trig Duosense Transparent Electromagnetic Digitizer Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 03f0:1807 Hewlett-Packard Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub sysop@wl083517:~$

    Read the article

  • IIS6 Virtual Directory 500 Error on Remote Share

    - by David
    We have our servers at the server farm in a domain. Let's call it LIVE. Our developer computers live in a completely separate corporate domain, miles and miles away. Let's call it CORP. We have a large central storage unit (unix) that houses images and other media needed by many webservers in the server farm. The IIS application pools run as (let's say) LIVE\MediaUser and use those credentials to connect to a central storage share as a virtual directory, retrieve the images, and serve them as if they were local on each server. The problem is in development. On my development machine. I log in as CORP\MyName. My IIS 6 application pool runs as Network Service. I can't run it as a user from the LIVE domain because my machine isn't (and can not be) joined to that domain. I try to create a virtual directory, point it to the same network directory, click Connect As, uncheck the "Always use the authenticated user's credentials when validating access to the network directory" checkbox so that I can enter the login info, enter the credentails for LIVE\MediaUser, click OK, verify the password, etc. This doesn't work. I get "HTTP Error 500 - Internal server error" from IIS. The IIS log file reports sc-status = 500, sc-substatus = 16, and sc-win32-status = 1326. The documentation says this means "UNC authorization credentials are incorrect" and the Win32 status means "Logon failure: unknown user name or bad password." This would be all and good if it were anywhere close to accurate. I double- and trouble-checked it. Tried multiple known good logins. The IIS manager allows me to view the file tree in its window, it's only the browser that kicks me out. I even tried going to the virtual directory's Directory Security tab, and under Authentication and Access Control, I tried using the same LIVE domain username for the anonymous access credential. No luck. I'm not trying to run any ASP, ASP.NET, or other dynamic anything out of the virtual directory. I just want IIS to be able to load static images, css, and js files. If anyone has some bright ideas I would be most appreciative!

    Read the article

  • Using Android 2.0 with Exchange server behind firewall

    - by Yurik
    Blackberry has an enterprise server that works with MS Exchange, and pushes all updates to the user's blackberry devices. We are considering switching to Android phones, which supposedly support Exchange servers. Will there be a similar program for Android? Are there any configuration changes that have to be done on Exchange server? (Exchange is behind the corp firewall).

    Read the article

  • How can access files on shared drive from Windows 2008 server configured with SFTP

    - by communicator
    I have installed OpenSSH on my windows 2008 server by following the user guide here . Now I have some files on windows network share with UNC path as \\corp\test\testdata I want map this file system on network share to my windows 2008 server which is configred with SFTP so that I can access these files from my Java Program by doing SFTP to windows 2008 server.Is there anyway I can map the network share to C or other drive in server so that all the files on the share will be available as local files on the server?

    Read the article

  • Graphics driver for ubuntu on dell latitude XT

    - by marc.riera
    we have a laptop (dell latitude xt) on our company, and we would like to install ubuntu on it. windows 7 works fine out of the box, so the hardware is fine. since this laptop has a touchscreen we just installed ubuntu 10.10 netbook edition 32x. But, we do not manage to enable the touchscreen, neither the vga graphic drivers. this is the output from lspci, if somebody cares. 00:00.0 Host bridge: ATI Technologies Inc Radeon Xpress 7930 Host Bridge 00:01.0 PCI bridge: ATI Technologies Inc RS7932 PCI Bridge 00:04.0 PCI bridge: ATI Technologies Inc Device 7934 00:06.0 PCI bridge: ATI Technologies Inc RS7936 PCI Bridge 00:07.0 PCI bridge: ATI Technologies Inc Device 7937 00:13.0 USB Controller: ATI Technologies Inc SB600 USB (OHCI0) 00:13.1 USB Controller: ATI Technologies Inc SB600 USB (OHCI1) 00:13.2 USB Controller: ATI Technologies Inc SB600 USB (OHCI2) 00:13.3 USB Controller: ATI Technologies Inc SB600 USB (OHCI3) 00:13.4 USB Controller: ATI Technologies Inc SB600 USB (OHCI4) 00:13.5 USB Controller: ATI Technologies Inc SB600 USB Controller (EHCI) 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 14) 00:14.1 IDE interface: ATI Technologies Inc SB600 IDE 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) 00:14.3 ISA bridge: ATI Technologies Inc SB600 PCI to LPC Bridge 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge 01:05.0 VGA compatible controller: ATI Technologies Inc Radeon Xpress 1250 03:01.0 CardBus bridge: Texas Instruments PCIxx12 Cardbus Controller 03:01.1 FireWire (IEEE 1394): Texas Instruments PCIxx12 OHCI Compliant IEEE 1394 Host Controller 03:01.3 SD Host controller: Texas Instruments PCIxx12 SDA Standard Compliant SD Host Controller 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5756ME Gigabit Ethernet PCI Express 0b:00.0 Network controller: Broadcom Corporation BCM4321 802.11a/b/g/n (rev 03) I've tryied to install ati drivers 9.3 , which I downloaded and installed, unpacked and installed, builded and installed, but nothing worked. Looks like the latests version is just accepted to work on jaunty 9.04, so they are kind of old. what else I can do? thanks. Marc Information added: lsusb and lspci -n |grep 01:05.0 sysop@wl083517:~$ lspci -n |grep 01:05.0 01:05.0 0300: 1002:7942 sysop@wl083517:~$ lsusb Bus 006 Device 002: ID 413c:8138 Dell Computer Corp. Wireless 5520 Voda I Mobile Broadband (3G HSDPA) Minicard EAP-SIM Port Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 002: ID 413c:8140 Dell Computer Corp. Wireless 360 Bluetooth Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 002: ID 0483:2016 SGS Thomson Microelectronics Fingerprint Reader Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 002: ID 1b96:0001 N-Trig Duosense Transparent Electromagnetic Digitizer Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 03f0:1807 Hewlett-Packard Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub sysop@wl083517:~$

    Read the article

  • BIND split-view DNS config problem

    - by organicveggie
    We have two DNS servers: one external server controlled by our ISP and one internal server controlled by us. I'd like internal requests for foo.example.com to map to 192.168.100.5 and external requests continue to map to 1.2.3.4, so I'm trying to configure a view in bind. Unfortunately, bind fails when I attempt to reload the configuration. I'm sure I'm missing something simple, but I can't figure out what it is. options { directory "/var/cache/bind"; forwarders { 8.8.8.8; 8.8.4.4; }; auth-nxdomain no; # conform to RFC1035 listen-on-v6 { any; }; }; zone "." { type hint; file "/etc/bind/db.root"; }; zone "localhost" { type master; file "/etc/bind/db.local"; }; zone "127.in-addr.arpa" { type master; file "/etc/bind/db.127"; }; zone "0.in-addr.arpa" { type master; file "/etc/bind/db.0"; }; zone "255.in-addr.arpa" { type master; file "/etc/bind/db.255"; }; view "internal" { zone "example.com" { type master; notify no; file "/etc/bind/db.example.com"; }; }; zone "example.corp" { type master; file "/etc/bind/db.example.corp"; }; zone "100.168.192.in-addr.arpa" { type master; notify no; file "/etc/bind/db.192"; }; I have excluded the entries in the view for allow-recursion and recursion in an attempt to simplify the configuration. If I remove the view and just load the example.com zone directly, it works fine. Any advice on what I might be missing?

    Read the article

  • IIS6 Virtual Directory 500 Error on Remote Share

    - by David Boike
    We have our servers at the server farm in a domain. Let's call it LIVE. Our developer computers live in a completely separate corporate domain, miles and miles away. Let's call it CORP. We have a large central storage unit (unix) that houses images and other media needed by many webservers in the server farm. The IIS application pools run as (let's say) LIVE\MediaUser and use those credentials to connect to a central storage share as a virtual directory, retrieve the images, and serve them as if they were local on each server. The problem is in development. On my development machine. I log in as CORP\MyName. My IIS 6 application pool runs as Network Service. I can't run it as a user from the LIVE domain because my machine isn't (and can not be) joined to that domain. I try to create a virtual directory, point it to the same network directory, click Connect As, uncheck the "Always use the authenticated user's credentials when validating access to the network directory" checkbox so that I can enter the login info, enter the credentails for LIVE\MediaUser, click OK, verify the password, etc. This doesn't work. I get "HTTP Error 500 - Internal server error" from IIS. The IIS log file reports sc-status = 500, sc-substatus = 16, and sc-win32-status = 1326. The documentation says this means "UNC authorization credentials are incorrect" and the Win32 status means "Logon failure: unknown user name or bad password." This would be all and good if it were anywhere close to accurate. I double- and trouble-checked it. Tried multiple known good logins. The IIS manager allows me to view the file tree in its window, it's only the browser that kicks me out. I even tried going to the virtual directory's Directory Security tab, and under Authentication and Access Control, I tried using the same LIVE domain username for the anonymous access credential. No luck. I'm not trying to run any ASP, ASP.NET, or other dynamic anything out of the virtual directory. I just want IIS to be able to load static images, css, and js files. If anyone has some bright ideas I would be most appreciative!

    Read the article

  • Active Directory : AdExplorer and LDAP browsers

    - by webwesen
    I can access my corp AD with SysInternals' "AdExplorer" with no problems. however, when I try to use generic LDAP browser (ldp.exe in my example) to access the same AD directory I can't get the required protocol/auth method. I think I have tried them all. what protocol/settings does AdExplorer use by default?

    Read the article

  • Pros and Cons of using internal or external domain name for Active Directory

    - by MadBoy
    I was always thought to use internal domain name (company.local or company.corp) for Active Directory instead of (company.com or company.pl). Recently we were thinking that by using external domain name we can get some advantages for stuff like certificates for Exchange, Sharepoint and alike where internal and external name would be exactly the same making it unnecessary to buy special certificates. What are advantages and disadvantages for both? What could be potential problem when doing so and what could be a big advantage?

    Read the article

< Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >