  • Resizing RAID 1 Array on Dell PowerEdge with Perc 4/Di & Windows SBS 2003

    - by Scott McKinney
    I have a Dell PowerEdge 2600 with Perc 4/Di RAID card and Windows SBS 2003 installed. The original system drive was a set of 17GB drives in a RAID 1 array. Over the years, these drives have failed (individually) and been replaced by a set of 73GB drives, but the RAID array is still 17GB in size. Is there a safe procedure to resize the RAID 1 array to use the entire 73GB without destroying/corrupting the data on the array? The Perc documentation mentions a Reconstruct option with Online Capacity Expansion, but is a woefully short on the exact details. Has anyone performed this procedure successfully (or unsuccessfully)? What were the steps? Are there any gotchas I should watch out for?

    Read the article

  • Very slow disk performance on Dell PowerEdge 2950 w/ PERC 6/i running RAID 10

    - by vocoder
    I recently set up a server running Ubuntu 10.04 LTS on a Dell PowerEdge 2950 server - it has 6 500 gb 7200RPM SATA drives setup in a RAID 10 config. I am seeing extremely poor disk performance - the RAID array reports all disks are normal and using MegaCLI, it looks like the BBU is fine. hdparm -tT /dev/sda reports: Timing cached reads: 90 MB in 2.05 seconds = 43.96 MB/sec Timing buffered disk reads: 24 MB in 3.11 seconds = 7.72 MB/sec So as you can see, it takes forever to something as simple as an apt-get upgrade and even logging into the server. How do I go about troubleshooting what is causing this? I upgraded the firmware on the PERC 6i RAID controller to the latest, but didn't see any improvements.

    Read the article

  • How to set up Dell OMSA tools on Debian 6 (Squeeze) (PE2950)

    - by javano
    I assume I have set up them up incorrectly or am missing a library or dependency. When I log into the OMSA web interface I can't see anything Also, omreport tells me nothing; root@box:~# omreport storage controller No controllers found I assume these two will use the same source of information so what ever is wrong will fix them both. I set up OMSA as per these instructions. Also I have compiled MegaCLI (as this is a PowerEdge 2950 with a Perc 6/i controller) and I have used that to update the RAID firmware, so that works, but the Dell tools aren't. What have I missed during set up? root@kvm1:~# cat /etc/issue Debian GNU/Linux 6.0 \n \l root@kvm1:~# uname -a Linux kvm1.mivoice.cust.vostron.net 3.4.9 #1 SMP Wed Aug 22 19:08:46 BST 2012 x86_64 GNU/Linux

    Read the article

  • Dell PE R710 Lifecycle Controller

    - by rihatum
    Hi All, How would one use the dell lifecycle controller on the new R710 Servers ? I have seen demos on youtube and it can install linux, windows from there without inserting the installation discs ? I am on the same LAN as the server and have setup iDrac Express (we dont have drac enterprise). Any suggestions ? Thanks

    Read the article

  • RAID 5 - DELL 2850 and others

    - by Kiara
    I have installed Ubuntu on a DELL 2850 and I have configured an array of 5 disks (SCSI 73GB 10K) in RAID5. I wanted to simulate a drive error so in the middle of something I just took one of the drives out and put it back again after a bit. Then the drive shows an orange light and seems to be rebuilding but actually is taking hours and hours with no results. So I went to the PERC utility (Ctrl+M) and the disk shows "REBLD". But it never gets to an online state. So I went to Objects - Physical drives - Rebuilding - View rebuild process. And in here I can see a bar moving from 0%... but if I reboot before finishing and get into the PERC Utility again, it seems to start again rebuilding from 0% - so it is not rebuilding automatically. My concern is: what would happen in a real situation? Do I have to just switch the server off and go to the Perc utility to start the rebuilding manually? I thought the whole point was to have this done automatically and without the need of stopping the server. Or does it perhaps rebuild automatically indeed but needs to have enough time without rebooting because otherwise the rebuilding process will start from scratch? It seems to take more than 3h for a 73gb disk! My second question is: can I mix then hard drives? So if I have a RAID of 5x73GB 10K can I use different size (146GB) or speeds (15K)? Apparently someone said it is OK in here Poweredge 2850: replace disk with larger in RAID?

    Read the article

  • Dell Inspiron 1564 overheating but fan not switching on, how to diagnose?

    - by Smugrik
    I've got a Dell Inspiron 1564 laptop that is about one and a half years old. Since about a week, the laptop started to overheat, causing it to switch off unexpectedly... The cpu fan is working erratically, it can start to spin for a while, doing its job and cooling down the cpu before it stops, but then the temperature goes up, and the fan doesn't reacts, once the temperature reaches a critical point (over 85 celsius, checked with speedfan...), the laptop switches off... I already cleaned the vents and fan from dust, to no avail, and it was actually quite clean anyway. Drivers and bios are up-to-date, no crapware was ever installed on this machine. I don't know how to diagnose the problem, could it be the temperature sensors that sends wrong information, so the fan doesn't reacts? but then I believe the computer wouldn't detect the overheat and stop... Is there a way I can pin point the problem? Maybe some low-level diagnostic tools to check functionality of sensors and fans??? The warranty is already over so any suggestion would be welcome. Thanks!!

    Read the article

  • dell server display on laptop screen

    - by hari
    Please redirect if this is not (and probably thats true) the correct forum/site. I have a dell server and I am trying to configure it for the first time. It is running windows server 2003. I do not have a monitor screen. Can I use laptop screen to display dell server and set it up? I mean to say is, if I can display dell server on laptop screen, it would be great. I am trying that with a dell laptop but not getting the display. Any help/pointer would be appreciated. Thanks in advance.

    Read the article

  • Restrict IPMI access on Dell BMC and iDRAC to an allowed IP range

    - by edgester
    I'm trying to secure the iDRAC's and BMC's on some of my Dell servers (R210, R410, R510). I want to restrict access to IPMI commands to only a few IP addresses. I've successfully restricted access to the iDrac using the instructions from http://support.dell.com/support/edocs/software/smdrac3/idrac/idrac10mono/en/ug/html/racugc2d.htm#wp1181529 , but the IP restrictions do not affect IPMI. A separate management network is not practical at this time because of lack or ports and some Dell BMC's don't offer a separate port. I'm told by my networking group that our switches don't support trunking, so using the vlan tagging is not an option either. Is there a way restrict the IPMI access to a list of allowed addresses? FYI, for various reasons, I have a mix of Dell servers with BMC's, iDrac Express and iDrac enterprise management features.

    Read the article

  • Trouble with wireless driver on a Dell Latitude D830

    - by Kevin
    After uninstalling Dell's wireless utility I get a new hardware found dialog that can not find any driver for my wifi card on it's own. I'm running Windows XP Professional Service Pack 3, and I would like to use the default wifi handler since dell's utility does not work with my company's wireless switch. I did try downloading the recommend driver from the dell support site Network Adapter 2 Model Intel(R) PRO/Wireless 3945ABG Network Connection Description [12] Intel(R) PRO/Wireless 3945ABG Network Connection Status Connected

    Read the article

  • Removing RAID on a DELL power-edge server

    - by Simon Callan
    We have a Dell Power-edge T110 server, with either a PERC S100 or S300 raid controller (I suspect S100), and 2 x 500GB SATA hard discs. These discs are running in RAID-1 configuration, (either 1 or 2 virtual discs), and on top of this, we have the C and D drives. As we are running low on disc space, we are looking at dropping the RAID to get some disc space back. Is it possible to split the discs back into 2 seperate hards discs that the OS can see, without losing all the data on the drives? Even better, would it be possible to split the D: drive, leaving the OS C: drive in RAID1 configuration?

    Read the article

  • Dell poweredge 1850's - wont install os

    - by user1326789
    I have 3 of these dell 1850 rack servers. 1 has 3GB RAM and 2 73GB HDD's. 2 have 6GB RAM and each of them has 2 73GB HDD's. I am currently trying to install an os on them but when i boot with windows xp setup, it gives me an error saying no partition found. Now i have set these drives up in RAID on the server and i put them "online" so it should be working fine but they're not. Please assist me in installing an operating system on these, i have no clue as to if it's the BIOS or the RAID controller within it. Thanks in advance, -Matt.

    Read the article

  • Docking Station Sound Doesn't Work on Dell D830 with Windows 7

    - by cisellis
    I have a Dell Latitude D830 laptop that is running Windows 7 Enterprise x64. I connect to a docking station during the day with multiple monitors, a keyboard and a mouse. Everything runs with no problems including most of the docking station ports (usb, monitors, etc.) However, the sound port from the docking station does not work since the upgrade to Windows-7. Even with the laptop plugged in, the sound always comes out of the laptop, not the headphones plugged into the docking station. Here's what I've tried: I've seen other issues like via Google this that seem to be mostly unanswered. I found one or two that referenced using the Vista x64 drivers, especially the Nvidia drivers. I do not have an Nvidia chipset but I've reinstalled the sound drivers and that has not helped. I don't have a support contract and considering the cost is usually high to call Dell, that's not an option. Dell's forums are pretty much a wasteland and I've found no help there. Since this is a docking station I thought I might need to try the SATA or Intel chipset drivers from the dell site instead, however I'm not really sure and I need to work on this laptop in the meantime. I can't really afford the downtime to experiment with random drivers all day in case they turn out to be incompatible (Dell still hasn't added Windows 7 to their support site as far as I can tell). Does anyone have any other ideas? Has anyone had this issue and solved it? If so, how? Thanks in advance for your help.

    Read the article

  • Dell replacement return

    - by terrani
    Hi, I am not sure if I can ask this question here. Please let me know if my question is not suitable here. I just received my replacement monitor from dell. While I was talking to dell tech., he told me that Dell would charge me for the replacement monitor if I fail to return my defective monitor within 15 days. I don't know why he told me that when I didn't ask it. so here is my question. How are they going to charge me?? Dell does not have my credit card or bank account info. Do they store my credit card or bank account information on their database???

    Read the article

  • How to use 3T SAS HDDs which aren't supported by Dell PERC 6i

    - by Sunry
    We bought several 3T SAS hard disks want to use with our Dell R710 server. But we found our R710 can't recognize the 3T hd, and then we dig out the raid card is PERC 6i which doesn't support it. Contacted with Dell that H700 and H800 support 3T hd, thought we can buy a H700 , but the SAS cable is not available in the market right now. And it seems very hard for us to change the raid card, also no suitable tools to tease the special screws. So I want to know if any other method to use these 3T hds instead of putting them in the warehouse? Can I low formatting it to 2TB, and plug it into Dell R710 to use? Or a SAS to USB adapter to use it as USB external disk? I just want to use them by Dell R710 even external.

    Read the article

  • Manage Dell workstations with OpenManage Essentials (OME)

    - by Jonathan Rioux
    How can I manage Dell workstations with OpenManage Essentials ? First, is it possible? Because iv read that only Dell servers can be managed with OME. I would like to inventory each Dell workstations I have in my environment, and be able to see their service tag with warranty expiration, etc. Or which product must I use to do this? There are so much Dell management products like OMCI, OMCC, ITA, etc!! I am so lost with all these products.

    Read the article

  • Imaging Dell OEM Windows 7 install onto other Dell laptops purchased

    - by lolkjmz
    We have ordered 70 dell laptops directly from dell. We are wondering if we can take the existing OEM install of windows on one of the laptops, add some files and then deploy that image to the rest of the laptops. We are trying to avoid making an image from the ground up. I would imagine since we have purchased 70 laptops that the same install would work on all 70 - I am not sure though. I have imaged three laptops with this image and attached them all onto the domain with no problems. They are also all activated. Updates ran fine as well. We are using this to duplicate drives http://www.startech.com/HDD/Duplicators/4-Bay-USB-3-0-eSATA-to-SATA-Standalone-1-3-HDD-Hard-Drive-Duplicator-Dock~SATDOCK4U3RE Will this method work or is there potential for problems in the future?

    Read the article

  • Flickering/Flashing screen problem related to keyboard

    - by LeandroCR
    This will seems quite bizarre but that's a huge problem for me, I'm facing it for a long time since Ubuntu 12.04. My Ubuntu/Linux Mint/Debian (Unity/Gnome) always starts flickering after using the computer for a while, I always thought this had something to do with the video board. I have an Vostro 3550 (Radeon 6xxx/Intel Onboard). First I realized that when I was navigating trough an website, when i selected with the mouse a combo, the combo closed it self automatically then the screen starts flickering. The i realized when i was trying to make the login in the terminal (crtl + alt + f1) a strange character appears, like: ^@ repeatedly. When i keep CRTL pressed the system never flickers! I have absolutely no problem using Windows. What can i do? There is no such thing as Keyboard driver on Dell Support. I would love to use Ubuntu only, but this is very annoying. Problem happens on Ubuntu 12.04, .10 and 13.04 Linux Mint 15 (Cinnamon) Debian Live with Gnome

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • Dell PE2950 - slow IO rates for writing and reading locally

    - by OrenM
    I'm having a serious issue with dell server PE2950. The server has really slow IO rates, so slow that I'm not able to use it anymore I tried few things to solve this: changing disks to new disks (configured them as raid1) changing perc card + perc cables reinstalling the OS of course, had to cause of changing of disks, centos 5.5 x64bit firmware update to everything virtual disks policy: No Read Ahead,Write Back, disk cache policy disabled. openmanage doesn't alert about anything, also i ran dell's diag tests, everything passed, also dell didn't see anything in deset log. dell offered to reseat everything, including the cpu, we did that as well, still io rates are slow I have several PE2950 servers, and I never had such a thing with any of those. All have similar or exact hardware as this one, all configured the same, with the same os centos 5.5 x64, same disks, same raid, same policy. Just for comparison: the problematic PE2950 server: [root@bad ~]# time sh -c "dd if=/dev/zero of=/tmp/ddfile bs=8k count=200000 && sync" 200000+0 records in 200000+0 records out 1638400000 bytes (1.6 GB) copied, 27.7946 seconds, 58.9 MB/s real 0m33.968s user 0m0.531s sys 0m26.000s good PE2950 server (with the exact same hardware): [root@good ~]# time sh -c "dd if=/dev/zero of=/tmp/ddfile bs=8k count=200000 && sync" 200000+0 records in 200000+0 records out 1638400000 bytes (1.6 GB) copied, 3.19999 seconds, 512 MB/s real 0m7.694s user 0m0.053s sys 0m4.057s Hopefully you will have an idea what can cause the problem.

    Read the article

  • Dell Driver Support for Latitude E6320 Windows 7 Enterprise

    - by IamPolaris
    I recently did a reinstall of Windows 7 Enterprise on a Dell Latitude E6320, which is a 64 bit system. After the install process, and doing typical Windows Update stuff, I looked at my Device Manager and found that I had devices which were missing drivers. My missing drivers: After going to the Dell Support site and looking at the files, and doing some sleuthing I found the following support document: http://downloads.dell.com/utility/Latitude%20E-Family%20%20Mobile%20Precision%20Re-Image%20How-To%20Guide%20-%20A03%20Rev%203%200.pdf This document hints in appendix C that the Broadcom USH is the Control Point Security and the Unknown device is Micro freefall sensor. The network controller is my wireless, as I cannot connect wirelessly, and the final missing driver I am not sure. Attempting to install the control point security exe on the support page will not work. After downloading, I am given the message that I am attempting to install a 32 bit driver on a 64 bit machine EVEN THOUGH I selected the win7 64 bit option from the support page. Beyond that, some of the drivers (Which are confusing to read and hard to understand what they do) and the system utilities which are supposedly supposed to make this process simpler will either a) not run because they are 32 bit exe's or b) the support page cannot find the file attempted to download. Is there anything I can do to get (at the very least) my wireless running, but idealistically all of my drivers. A solution which assumes Dell is completely incompetent would be ideal. :P Some forums have said that I should download the chipset driver, others say to get the system utility file (DSS_UTIL_WIN_R282536.EXE). I have had no luck as of yet...

    Read the article

  • Remove Dell Openmanage from Windows 2008

    - by Erwin Blonk
    I have installed Dell Openmanage Server Agent 4.2.2 on Windows Server 2008. I need the newer version, so I need to install this version first. However, outside some registry references pointing to sources that aren't there, there is little or no trace of it being installed. For example, no trace of the program files or an entry in Prgrams And Features. Still, installing a newer version keeps coming up with an older version that needs to be removed first. When I try to install version 4.2.2 to repair and eventually remove it, it gives an error: Dell Openmanage Server Agent - Error An error was encountered while testing machine type. Failure openingen required handle to .DLL. Dell Openmanage Server Agent cannot continue the installation. Setup will exit now. I haven't found anything using different parts of the error messages as search terms.

    Read the article

  • Dell OpenManage Causing Periodic Slowness

    - by Zorlack
    Today we diagnosed the cause of a Periodic slowness issue: see here. Dell OpenManage Server Administrator seems to have been causing hourly slowness. It would occasionally peg one of the CPUs for upwards of two minutes. Disabling it drastically improved the performance of the SQL Server. The server hardware: Dell R710 Dual Quad Core 2.9GHz Processors 96GB Memory 2 Disk RAID 1 SAS System Disk (Internal) 4 Disk RAID 10 SAS Log Disk (Internal) 14 Disk RAID 10 SAS Data Disk (External DAS MD1000) Windows 2008 Enterprise R2 x64 We installed the OS using Dell OpenManage Server Assistant, so I assume that it was correctly configured. For now we have disabled OMSA to alleviate the performance issues it was causing, but I'd like to be able to re-enable it. Has anyone had a similar experience that can shed a little light on the nature of this problem?

    Read the article

  • Dell printer goes offline after second print job.

    - by Ac0ua
    Dell printer goes offline(server connection) after second print job. Although the printer's display says it is ready. If you turn off then on the printer you can send one job and goes back offline(server connection) on the next print job. We have multiple Dell 2330dn printers installed through a print server, only one of the printers is experiencing this problem. Two different users. Two different machines. Two different operating systems (win7 and Vista). The computers have been reset. Dell printers have web interface if this helps (through IP address). Thanks for any help!

    Read the article

  • Install Windows Server 2008 Core on a Dell Optiplex 790

    - by Alex Marshall
    Does anybody have experience installing Windows Server 2008 Core on a Dell Optiplex 790? When I connect to the machine with the Hyper-V Manager Administrator snap-in, and try to create and run a virtual machine, I get the error "The Virtual Machine could not be started because the hypervisor is not running". I've disabled the Execute Disable functionality in the BIOS as was requried for other Dell models, but no matter what combination of security and virtualization settings I use on the machine, I can't get this working. EDIT: I've installed Windows Server 2008 Core on a Dell Optiplex 790, and I'm trying to install and setup a guest VM on the Hypervisor EDIT 2: The Hyper-V role is installed and configured, without any errors in the event log. Hardware-assisted virtualization is also enabled.

    Read the article

  • Dell Vostro 1000 w/fresh XP Pro installation running very slow

    - by Ssvarc
    I'm working on a Dell Vostro 1000 laptop. It was running slowly and hanging, antivirus scans turned up nothing and the same with the Dell diagnostics (DFT hung - but Dell's diagnostics gave the HD a pass) so I imaged the HD and installed XP Pro on it. The laptop is still slow! (It takes a noticeable delay to enter words into the Google search box in IE and the computer hangs every time it enters the XP screensaver.) What are the likely possibilities at this point and how would I go about checking for them?

    Read the article