Search Results

Search found 153 results on 7 pages for 'norton'.

Page 7/7 | < Previous Page | 3 4 5 6 7 

  • Refreshing Your PC Won’t Help: Why Bloatware is Still a Problem on Windows 8

    - by Chris Hoffman
    Bloatware is still a big problem on new Windows 8 and 8.1 PCs. Some websites will tell you that you can easily get rid of manufacturer-installed bloatware with Windows 8′s Reset feature, but they’re generally wrong. This junk software often turns the process of powering on your new PC from what could be a delightful experience into a tedious slog, forcing you to spend hours cleaning up your new PC before you can enjoy it. Why Refreshing Your PC (Probably) Won’t Help Manufacturers install software along with Windows on their new PCs. In addition to hardware drivers that allow the PC’s hardware to work properly, they install more questionable things like trial antivirus software and other nagware. Much of this software runs at boot, cluttering the system tray and slowing down boot times, often dramatically. Software companies pay computer manufacturers to include this stuff. It’s installed to make the PC manufacturer money at the cost of making the Windows computer worse for actual users. Windows 8 includes “Refresh Your PC” and “Reset Your PC” features that allow Windows users to quickly get their computers back to a fresh state. It’s essentially a quick, streamlined way of reinstalling Windows.  If you install Windows 8 or 8.1 yourself, the Refresh operation will give your PC a clean Windows system without any additional third-party software. However, Microsoft allows computer manufacturers to customize their Refresh images. In other words, most computer manufacturers will build their drivers, bloatware, and other system customizations into the Refresh image. When you Refresh your computer, you’ll just get back to the factory-provided system complete with bloatware. It’s possible that some computer manufacturers aren’t building bloatware into their refresh images in this way. It’s also possible that, when Windows 8 came out, some computer manufacturer didn’t realize they could do this and that refreshing a new PC would strip the bloatware. However, on most Windows 8 and 8.1 PCs, you’ll probably see bloatware come back when you refresh your PC. It’s easy to understand how PC manufacturers do this. You can create your own Refresh images on Windows 8 and 8.1 with just a simple command, replacing Microsoft’s image with a customized one. Manufacturers can install their own refresh images in the same way. Microsoft doesn’t lock down the Refresh feature. Desktop Bloatware is Still Around, Even on Tablets! Not only is typical Windows desktop bloatware not gone, it has tagged along with Windows as it moves to new form factors. Every Windows tablet currently on the market — aside from Microsoft’s own Surface and Surface 2 tablets — runs on a standard Intel x86 chip. This means that every Windows 8 and 8.1 tablet you see in stores has a full desktop with the capability to run desktop software. Even if that tablet doesn’t come with a keyboard, it’s likely that the manufacturer has preinstalled bloatware on the tablet’s desktop. Yes, that means that your Windows tablet will be slower to boot and have less memory because junk and nagging software will be on its desktop and in its system tray. Microsoft considers tablets to be PCs, and PC manufacturers love installing their bloatware. If you pick up a Windows tablet, don’t be surprised if you have to deal with desktop bloatware on it. Microsoft Surfaces and Signature PCs Microsoft is now selling their own Surface PCs that they built themselves — they’re now a “devices and services” company after all, not a software company. One of the nice things about Microsoft’s Surface PCs is that they’re free of the typical bloatware. Microsoft won’t take money from Norton to include nagging software that worsens the experience. If you pick up a Surface device that provides Windows 8.1 and 8 as Microsoft intended it — or install a fresh Windows 8.1 or 8 system — you won’t see any bloatware. Microsoft is also continuing their Signature program. New PCs purchased from Microsoft’s official stores are considered “Signature PCs” and don’t have the typical bloatware. For example, the same laptop could be full of bloatware in a traditional computer store and clean, without the nasty bloatware when purchased from a Microsoft Store. Microsoft will also continue to charge you $99 if you want them to remove your computer’s bloatware for you — that’s the more questionable part of the Signature program. Windows 8 App Bloatware is an Improvement There’s a new type of bloatware on new Windows 8 systems, which is thankfully less harmful. This is bloatware in the form of included “Windows 8-style”, “Store-style”, or “Modern” apps in the new, tiled interface. For example, Amazon may pay a computer manufacturer to include the Amazon Kindle app from the Windows Store. (The manufacturer may also just receive a cut of book sales for including it. We’re not sure how the revenue sharing works — but it’s clear PC manufacturers are getting money from Amazon.) The manufacturer will then install the Amazon Kindle app from the Windows Store by default. This included software is technically some amount of clutter, but it doesn’t cause the problems older types of bloatware does. It won’t automatically load and delay your computer’s startup process, clutter your system tray, or take up memory while you’re using your computer. For this reason, a shift to including new-style apps as bloatware is a definite improvement over older styles of bloatware. Unfortunately, this type of bloatware has not replaced traditional desktop bloatware, and new Windows PCs will generally have both. Windows RT is Immune to Typical Bloatware, But… Microsoft’s Windows RT can’t run Microsoft desktop software, so it’s immune to traditional bloatware. Just as you can’t install your own desktop programs on it, the Windows RT device’s manufacturer can’t install their own desktop bloatware. While Windows RT could be an antidote to bloatware, this advantage comes at the cost of being able to install any type of desktop software at all. Windows RT has also seemingly failed — while a variety of manufacturers came out with their own Windows RT devices when Windows 8 was first released, they’ve all since been withdrawn from the market. Manufacturers who created Windows RT devices have criticized it in the media and stated they have no plans to produce any future Windows RT devices. The only Windows RT devices still on the market are Microsoft’s Surface (originally named Surface RT) and Surface 2. Nokia is also coming out with their own Windows RT tablet, but they’re in the process of being purchased by Microsoft. In other words, Windows RT just isn’t a factor when it comes to bloatware — you wouldn’t get a Windows RT device unless you purchased a Surface, but those wouldn’t come with bloatware anyway. Removing Bloatware or Reinstalling Windows 8.1 While bloatware is still a problem on new Windows systems and the Refresh option probably won’t help you, you can still eliminate bloatware in the traditional way. Bloatware can be uninstalled from the Windows Control Panel or with a dedicated removal tool like PC Decrapifier, which tries to automatically uninstall the junk for you. You can also do what Windows geeks have always tended to do with new computers — reinstall Windows 8 or 8.1 from scratch with installation media from Microsoft. You’ll get a clean Windows system and you can install only the hardware drivers and other software you need. Unfortunately, bloatware is still a big problem for Windows PCs. Windows 8 tries to do some things to address bloatware, but it ultimately comes up short. Most Windows PCs sold in most stores to most people will still have the typical bloatware slowing down the boot process, wasting memory, and adding clutter. Image Credit: LG on Flickr, Intel Free Press on Flickr, Wilson Hui on Flickr, Intel Free Press on Flickr, Vernon Chan on Flickr     

    Read the article

  • Cannot ping router with a static IP assigned?

    - by Uriah
    Alright. I am running Ubuntu LTS 12.04 and am trying to configure a local caching/master DNS server so I am using Bind9. First, here are some things via default DHCP: /etc/network/interfaces cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet dhcp # The primary network interface - STATIC #auto eth0 #iface eth0 inet static # address 192.168.2.113 # netmask 255.255.255.0 # network 192.168.2.0 # broadcast 192.168.2.255 # gateway 192.168.2.1 # dns-search uclemmer.net # dns-nameservers 192.168.2.113 8.8.8.8 /etc/resolv.conf cat /etc/resolv.conf # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN nameserver 192.168.2.1 search uclemmer.net ifconfig ifconfig eth0 Link encap:Ethernet HWaddr 00:14:2a:82:d4:9e inet addr:192.168.2.103 Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: fe80::214:2aff:fe82:d49e/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1067 errors:0 dropped:0 overruns:0 frame:0 TX packets:2504 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:153833 (153.8 KB) TX bytes:214129 (214.1 KB) Interrupt:23 Base address:0x8800 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:915 errors:0 dropped:0 overruns:0 frame:0 TX packets:915 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:71643 (71.6 KB) TX bytes:71643 (71.6 KB) ping ping -c 4 192.168.2.1 PING 192.168.2.1 (192.168.2.1) 56(84) bytes of data. 64 bytes from 192.168.2.1: icmp_req=1 ttl=64 time=0.368 ms 64 bytes from 192.168.2.1: icmp_req=2 ttl=64 time=0.224 ms 64 bytes from 192.168.2.1: icmp_req=3 ttl=64 time=0.216 ms 64 bytes from 192.168.2.1: icmp_req=4 ttl=64 time=0.237 ms --- 192.168.2.1 ping statistics --- 4 packets transmitted, 4 received, 0% packet loss, time 2997ms rtt min/avg/max/mdev = 0.216/0.261/0.368/0.063 ms ping -c 4 google.com PING google.com (74.125.134.102) 56(84) bytes of data. 64 bytes from www.google-analytics.com (74.125.134.102): icmp_req=1 ttl=48 time=15.1 ms 64 bytes from www.google-analytics.com (74.125.134.102): icmp_req=2 ttl=48 time=11.4 ms 64 bytes from www.google-analytics.com (74.125.134.102): icmp_req=3 ttl=48 time=11.6 ms 64 bytes from www.google-analytics.com (74.125.134.102): icmp_req=4 ttl=48 time=11.5 ms --- google.com ping statistics --- 4 packets transmitted, 4 received, 0% packet loss, time 3003ms rtt min/avg/max/mdev = 11.488/12.465/15.118/1.537 ms ip route ip route default via 192.168.2.1 dev eth0 metric 100 192.168.2.0/24 dev eth0 proto kernel scope link src 192.168.2.103 As you can see, with DHCP everything seems to work fine. Now, here are things with static IP: /etc/network/interfaces cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # The primary network interface #auto eth0 #iface eth0 inet dhcp # The primary network interface - STATIC auto eth0 iface eth0 inet static address 192.168.2.113 netmask 255.255.255.0 network 192.168.2.0 broadcast 192.168.2.255 gateway 192.168.2.1 dns-search uclemmer.net dns-nameservers 192.168.2.1 8.8.8.8 I have tried dns-nameservers in various combos of *.2.1, *.2.113, and other reliable, public nameservers. /etc/resolv.conf cat /etc/resolv.conf # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN nameserver 192.168.2.1 nameserver 8.8.8.8 search uclemmer.net Obviously, when I change the nameservers in the /etc/network/interfaces file, the nameservers change here too. ifconfig ifconfig eth0 Link encap:Ethernet HWaddr 00:14:2a:82:d4:9e inet addr:192.168.2.113 Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: fe80::214:2aff:fe82:d49e/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1707 errors:0 dropped:0 overruns:0 frame:0 TX packets:2906 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:226230 (226.2 KB) TX bytes:263497 (263.4 KB) Interrupt:23 Base address:0x8800 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:985 errors:0 dropped:0 overruns:0 frame:0 TX packets:985 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:78625 (78.6 KB) TX bytes:78625 (78.6 KB) ping ping -c 4 192.168.2.1 PING 192.168.2.1 (192.168.2.1) 56(84) bytes of data. --- 192.168.2.1 ping statistics --- 4 packets transmitted, 0 received, 100% packet loss, time 3023ms ping -c 4 google.com ping: unknown host google.com Lastly, here are my bind zone files: /etc/bind/named.conf.options cat /etc/bind/named.conf.options options { directory "/etc/bind"; // // // query-source address * port 53; notify-source * port 53; transfer-source * port 53; // If there is a firewall between you and nameservers you want // to talk to, you may need to fix the firewall to allow multiple // ports to talk. See http://www.kb.cert.org/vuls/id/800113 // If your ISP provided one or more IP addresses for stable // nameservers, you probably want to use them as forwarders. // Uncomment the following block, and insert the addresses replacing // the all-0's placeholder. // forwarders { // 0.0.0.0; // }; forwarders { // My local 192.168.2.113; // Comcast 75.75.75.75; 75.75.76.76; // Google 8.8.8.8; 8.8.4.4; // DNSAdvantage 156.154.70.1; 156.154.71.1; // OpenDNS 208.67.222.222; 208.67.220.220; // Norton 198.153.192.1; 198.153.194.1; // Verizon 4.2.2.1; 4.2.2.2; 4.2.2.3; 4.2.2.4; 4.2.2.5; 4.2.2.6; // Scrubit 67.138.54.100; 207.255.209.66; }; // // // //allow-query { localhost; 192.168.2.0/24; }; //allow-transfer { localhost; 192.168.2.113; }; //also-notify { 192.168.2.113; }; //allow-recursion { localhost; 192.168.2.0/24; }; //======================================================================== // If BIND logs error messages about the root key being expired, // you will need to update your keys. See https://www.isc.org/bind-keys //======================================================================== dnssec-validation auto; auth-nxdomain no; # conform to RFC1035 listen-on-v6 { any; }; }; /etc/bind/named.conf.local cat /etc/bind/named.conf.local // // Do any local configuration here // // Consider adding the 1918 zones here, if they are not used in your // organization //include "/etc/bind/zones.rfc1918"; zone "example.com" { type master; file "/etc/bind/zones/db.example.com"; }; zone "2.168.192.in-addr.arpa" { type master; file "/etc/bind/zones/db.2.168.192.in-addr.arpa"; /etc/bind/zones/db.example.com cat /etc/bind/zones/db.example.com ; ; BIND data file for example.com interface ; $TTL 604800 @ IN SOA yossarian.example.com. root.example.com. ( 1343171970 ; Serial 604800 ; Refresh 86400 ; Retry 2419200 ; Expire 604800 ) ; Negative Cache TTL ; @ IN NS yossarian.example.com. @ IN A 192.168.2.113 @ IN AAAA ::1 @ IN MX 10 yossarian.example.com. ; yossarian IN A 192.168.2.113 router IN A 192.168.2.1 printer IN A 192.168.2.200 ; ns01 IN CNAME yossarian.example.com. www IN CNAME yossarian.example.com. ftp IN CNAME yossarian.example.com. ldap IN CNAME yossarian.example.com. mail IN CNAME yossarian.example.com. /etc/bind/zones/db.2.168.192.in-addr.arpa cat /etc/bind/zones/db.2.168.192.in-addr.arpa ; ; BIND reverse data file for 2.168.192.in-addr interface ; $TTL 604800 @ IN SOA yossarian.example.com. root.example.com. ( 1343171970 ; Serial 604800 ; Refresh 86400 ; Retry 2419200 ; Expire 604800 ) ; Negative Cache TTL ; @ IN NS yossarian.example.com. @ IN A 255.255.255.0 ; 113 IN PTR yossarian.example.com. 1 IN PTR router.example.com. 200 IN PTR printer.example.com. ip route ip route default via 192.168.2.1 dev eth0 metric 100 192.168.2.0/24 dev eth0 proto kernel scope link src 192.168.2.113 I can SSH in to the machine locally at *.2.113 or at whatever address is dynamically assigned when in DHCP "mode". *2.113 is in my router's range and I have ports open and forwarding to the server. Pinging is enabled on the router too. I briefly had a static configuration working but it died after the first reboot. Please let me know what other info you might need. I am beyond frustrated/baffled.

    Read the article

  • Windows CE Chat Transcript (March 30, 2010)

    - by Bruce Eitman
    For those of you who missed the chat today, here is the raw transcript.   By raw, I mean that I copied and pasted the discussion without any edits. This is divided into two parts, the top part is the answers from the Microsoft Experts and the bottom part is the questions from the audience. Answers from Microsoft:   Karel Danihelka [MS] (Expert)[2010-3-30 12:2]: Hi everyone, my name is Karel Danihelka and I am developer in partner response team. Sing Wee [MS] (Expert)[2010-3-30 12:2]: Hi, I'm Sing Wee, part of the CoreOS/BSP Test Team. GLanger_MS (Expert)[2010-3-30 12:2]: Hi, I'm Glen Langer, program manager on the Core Team. Karel Danihelka [MS] (Expert)[2010-3-30 12:3]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? A: Until you are using CPU with GHz frequency your only chance is use interrupt handler and implement all funcionality there. But it will be really tricky and may reduce system performance. If period will be near to millisecond timeframe you can use normal thread wait for event pattern. Karel Danihelka [MS] (Expert)[2010-3-30 12:5]: Q: I want to partition my NAND Flash device. One partition to use for hive ragistry and the other for the apps and data. The only way to do it is programmatically or setting some registry values ? A: It need to be set in registry - generally you need mark this partition as boot partition. Karel Danihelka [MS] (Expert)[2010-3-30 12:7]: Q: My CPU is Intel celeron M processor 1Ghz. A: In this case you can try use normal approach - in interrupt handler return SYSINTR and start thread in device driver which will spin thread waiting on event attached to this SYSINTR. Karel Danihelka [MS] (Expert)[2010-3-30 12:7]: Q: If i need to implement it using interrupt handlers, What are all the files that I should look at? A: Good quesiton - I would recommend documentation and there was BSP development book to download for free. mikehall_ms (Moderator)[2010-3-30 12:8]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? A: Using product support is the formal way to report bugs/issues - Product support can then create an issue that can be tracked. Karel Danihelka [MS] (Expert)[2010-3-30 12:9]: Q: But the operation for creating the partitions ? A: This is tricky - if you will make it autopartition & autoformat it will be created by filesystem. But generally it depends on your boot loader. mikehall_ms (Moderator)[2010-3-30 12:10]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: At MIX 2010 Charlie Kindel presented a session that described some of the core technologies that make up Windows Phone 7 Series, including the underlying operating system (Windows CE) and the new ISV programming model based on Silverlight and .NET - check out the Mix Online Videos to get more information. davbo-msft (Moderator)[2010-3-30 12:10]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: This forum is to discussed released products in the industry. Windows Mobile & Windows CE are based on the same Windows CE Kernel/system. Windows CE is focused on deliverying the OS for embedded customers in the market where Windows Mobile is focused on deliverying compelling Windows Phone platform. davbo-msft (Moderator)[2010-3-30 12:11]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: http://en.wikipedia.org/wiki/Windows_CE Wikipedia gives a good breakdown of the version history. Travis Hobrla [MS] (Expert)[2010-3-30 12:13]: Q: I created a OS design with KITL and kernel debugger enabled. But I am unable to connect to the target for debugging. I am getting the following error when i try to connect with the device. PB Debugger Cannot initialize the Kernel Debugger. PB Debugger Debugger could not initialize connection. PB Debugger The Kernel Debugger is waiting to connect with target. PB Debugger The Kernel Debugger has been disconnected successfully. A: One possibility is that a rogue cesvchost.exe has co-opted the debugger. I am assuming this is CE 6.0? Can you try exiting visual studio and manually killing the cesvchost.exe process from the Task Manager? davbo-msft (Moderator)[2010-3-30 12:14]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? A: For info on contacting Microsoft support refer to the support page on the Embedded website: http://msdn.microsoft.com/en-us/windowsembedded/dd897633.aspx Sing Wee [MS] (Expert)[2010-3-30 12:16]: Q: Do u mean ISR/IST implementation? How can i register an interrupt? What kind of interrupt should i register? A: A good introduction to interrupts in WinCE 6.0 can be found here (aside from the documentation on MSDN): http://download.microsoft.com/download/9/c/f/9cffaa58-4000-48d6-a4b2-5fed9e4e6410/Chapter%206%20-%20Developing%20Device%20Drivers.pdf mikehall_ms (Moderator)[2010-3-30 12:16]: Q: What will be different in Windows Compact 7 from CE 6.0? A: Unfortunately we cannot discuss unreleased products on this chat - keep an eye on the Windows Embedded web site and blogs to keep up to date with product announcements. Travis Hobrla [MS] (Expert)[2010-3-30 12:16]: Q: I am using CE 6.0. There is no cesvchost process running in my system. A: What operating system are you using? Karel Danihelka [MS] (Expert)[2010-3-30 12:16]: Q: So...I have to modify file system code to create 2 partition at system startup ?!! I haven't understood.... A: You don't need to modify code, there are registry settings to achive this (look to documentation). But you may need to create partition table in boot loader. Unfortunatelly there isn't simple way how to do it. davbo-msft (Moderator)[2010-3-30 12:18]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Windows Embedded CE 6.0 R3 includes Sliverlight for Windows Embedded. Refer to New Features overview on the embedded web site. http://www.microsoft.com/windowsembedded/en-us/products/windowsce/default.mspx. Silverlight - The power of Silverlight brought to Windows Embedded CE to create rich applications and user interfaces is new part of Windows CE Embedded. mikehall_ms (Moderator)[2010-3-30 12:20]: Q: The link for developing device drivers is not working. can u please check that? A: http://msdn.microsoft.com/en-us/library/ms923714.aspx davbo-msft (Moderator)[2010-3-30 12:20]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Sorry misunderstood the question I thought you were asking if embedded CE could handle Silverlight. Please repost so that the question goes back into the active queue because once answered no way to put the status back to open. Travis Hobrla [MS] (Expert)[2010-3-30 12:21]: Q: sorry! Windows XP SP3 A: Can you try exiting VS2005 and confirming cesvchost.exe is not running, then renaming C:\Documents and Settings\USERNAME\Local Settings\Application Data\Microsoft\CoreCon\1.0 to 1.0_backup, then restarting VS2005? Sing Wee [MS] (Expert)[2010-3-30 12:24]: Q: Can I have the book's name please? A: I believe the downloadable version is related to the last link I sent. If you go to the following website, I believe you can download the whole thing: http://msdn.microsoft.com/en-us/windowsembedded/ce/cc294468.aspx davbo-msft (Moderator)[2010-3-30 12:24]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? A: change the URI of the image or use a writeable bitmap if they want to manually toggle the pixels Sing Wee [MS] (Expert)[2010-3-30 12:25]: A: Whoops, hit [ENTER] too early. On the right side, you'll see there an "Exam Preparation Kit" link that can be downloaded in several different languages. Sing Wee [MS] (Expert)[2010-3-30 12:25]: Q: Can I have the book's name please? A: Whoops, hit [ENTER] too early. On the right side, you'll see there an "Exam Preparation Kit" link that can be downloaded in several different languages. Karel Danihelka [MS] (Expert)[2010-3-30 12:26]: Q: I have a NAND Flash on my target device. On this flash I have the hive registry and an application.I have observed that when the NAND flash is fully, the system startup time is longer....is there a degradation of NAND use that influences the startup time ? Why ? A: Yes - on boot flash abstraction library (old one) read metadata from all sectors to rebuild physical - logical mapping table. davbo-msft (Moderator)[2010-3-30 12:27]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Need addition info on this question. Can you provide more details on what you are trying to do in Silverlight? davbo-msft (Moderator)[2010-3-30 12:27]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? A: Additonal Info: if you want to manually touch the pixels use WriteableBitmap if you want to use the underlying HWND then use IXRVisualHost::GetHWND() davbo-msft (Moderator)[2010-3-30 12:28]: Q: Writable bitmap, is there an example of the syntax? A: if you want to manually touch the pixels use WriteableBitmap if you want to use the underlying HWND then use IXRVisualHost::GetHWND() davbo-msft (Moderator)[2010-3-30 12:29]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Can I get more information about this question about what you are trying to accomplish in Silverlight? davbo-msft (Moderator)[2010-3-30 12:31]: Q: IXRVisualHost::GetHWND() exactly what I needed Thanks, A: Your welcome Sing Wee [MS] (Expert)[2010-3-30 12:31]: Q: ok. thanks for the book's link A: No problem. Travis Hobrla [MS] (Expert)[2010-3-30 12:32]: Q: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. A: There are a couple workarounds I can think of. I believe the Module element is only used when doing SYSGEN parsing to make sure dependent SYSGENs are present when the item is selected, so I believe it is optional to the catalog. The other obvious workaround is to shorten the soc name. I realize neither of these solutions is ideal. This is not something we anticipated when we tested CE6.0, sorry. Travis Hobrla [MS] (Expert)[2010-3-30 12:33]: Q: I am getting this error only when I select the KdStub as the debugger in Target device connectivity. A: Right, but KdStub is the debugger that you should use. Have you tried the steps I suggested? Travis Hobrla [MS] (Expert)[2010-3-30 12:36]: Q: If I select Active KTIL, My OS doesn't boots. It says "loading NK.EXE at 0x<xxxxx> location" after that nothing comes in the debug log. A: Can you look at the serial debug output and see what is happening there? Often it can give you a clue to the KITL driver malfunctioning. Travis Hobrla [MS] (Expert)[2010-3-30 12:38]: Q: I have tried that and I am getting the same error. A: I am assuming you have a device created in Target -> Connectivity Options in Platform Builder. What are the Kernel download / Kernel transport for your device? Travis Hobrla [MS] (Expert)[2010-3-30 12:40]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug A: This looks reasonable and does not give clues as to why boot would halt at that point. If you capture a network trace or turn on KITL debug zones via dpCurSettings in kitl.dll, do you see KITL active after this? Travis Hobrla [MS] (Expert)[2010-3-30 12:41]: Q: Both is happening via Ethernet. A: Only thing I have left to suggest is a Platform Builder installation Repair, then. Karel Danihelka [MS] (Expert)[2010-3-30 12:42]: Q: Hi, I saw that the ATADISK is quite generic and des not have any optimizations. Do you have any advice to consider while tryin to improve the performance of it? A: If I remember correctly sample code has support for some specific hardware controllers (little obsolete now). This should be good start point (if you will not decide take existing driver as sample and write you own). Travis Hobrla [MS] (Expert)[2010-3-30 12:44]: Q: I didn't do that. I have to try. A: I think that's the next valid step. You need to figure out whether KITL is hanging or the device - use instrumented serial debug messages and network trace to determine this. Sing Wee [MS] (Expert)[2010-3-30 12:46]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug A: Neo, have you by any chance tried looking into your firewall to see if it might be blocking traffic on any particular ports? Wireshark/netmon might be able to help you here if that's the issue. davbo-msft (Moderator)[2010-3-30 12:48]: Q: I lost spell check, how can i get it back A: Hello - can you give additional details about your question? Is this related to a Windows CE Embedded application? masatos_MSFT (Expert)[2010-3-30 12:51]: Q: When attempting to run the CETK cellcore tests the documentation states the pre-requisites include "stinger.ini", "ltk.ini" but windows CE doesn't provide these or document what they fully need to contain. Implicitly you also need "datatrans.xml" which isn't supplied. If you get around this error and steal these from Windows Mobile instead, when you try and run the CETK tests you get a data abort in radiometricsdll.dll. How should we invoke the cellcore parts of CETK? A: Hi Pev, what version of Windows CE and CETK are you using? I do not have the expertise to answer this question, but can find somebody who can. Travis Hobrla [MS] (Expert)[2010-3-30 12:52]: Q: I don't see a kitlcore.dll in my OS. is my debug image fails to load because of that? A: kitl.dll should be all that's needed, kitlcore.lib is linked into that. Travis Hobrla [MS] (Expert)[2010-3-30 12:55]: Q: I've got a platform (not developed by myself) where I2C bus support has to be provided through the OAL as the kernel needs to talk to devices such as the power management IC and gas gauge so a 'proper' I2C driver hanging off device manager isn't possible. This happens to be a polled driver, so obviously it hits the system hard when either under lots of traffic or an error condition occurs and the driver constantly polls. I originally thought that there was no straightforward way to make such code interrupt driven in the kernel (as it's a cludge) but I realised that that's exactly what ETHDBG drivers do. Is there any reason why I shouldn't have a go at implementing a similar mechanism for our kernel resident I2C driver? If not, are there any obvious pitfalls - I've not seen any other BSP's do this in the past... A: You can make a 'proper' driver that calls down into the OAL to do the actual I2C transactions. Alternatively you can build an interrupt-based version in the OAL where you handle everything in the ISR. There is nothing wrong with that so long as the rest of your drivers and app threads can handle longer times with interrupts off while you are servicing I2C interrupts. Sing Wee [MS] (Expert)[2010-3-30 12:55]: Q: I am having trouble with my mouse, I have the microsoft wireless mobile mouse 3000, when I push the scroll button I am suppose to have autoscroll instead it shows other web pages,Can you help me out tell me what to do!!! A: Sorry, this current chat is about Windows Embedded Compact. Hope you're able to find an answer to your question elsewhere. davbo-msft (Moderator)[2010-3-30 12:56]: Q: Is the Silverlight Animation "Spline" a BezierSpline? A: Spline - http://msdn.microsoft.com/en-us/library/ee501495.aspx<BR< a>>   masatos_MSFT (Expert)[2010-3-30 12:57]: Thanks for the info Pev. I will follow up with the CETK experts here and get back to you. davbo-msft (Moderator)[2010-3-30 12:59]: Q: Spline- bad link A: http://msdn.microsoft.com/en-us/library/ee501495.aspx davbo-msft (Moderator)[2010-3-30 13:0]: Q: Sorry, got to tirm the ">" A: No Worries http://msdn.microsoft.com/en-us/library/ee501495.aspx davbo-msft (Moderator)[2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; davbo-msft (Moderator)[2010-3-30 13:1]: Q: hi everybody. I would like to know if there is something know about a bug in RTC API (VOIP), especially when using SIP. According the to the analysis with application verifyier there is a heap link in rtcdllmedia.dll. All of the unreleased chunks seem to have a size of 6560 bytes. A: I will follow up with the Networking Team for a response. davbo-msft (Moderator)[2010-3-30 13:1]: Q: Hi, we've problems with debugging of applications (= breakpoints in Platform Builder will be ignored) over KITL on Windows CE 5.0, if the PDB files are large (over 60MB). Are there any limitations to size of the PDB files? A: I will follow up with the tools team for a response and post with the transcript. Sing Wee [MS] (Expert)[2010-3-30 13:1]: Q: I am unable to use the target control in my development environment. any ideas? A: Make sure you have SYSGEN_SHELL=1 set in your build environment. davbo-msft (Moderator)[2010-3-30 13:3]: Q: what are the main differences between Object Store and RAM disk ? They are both in RAM...are there performance differences ? access differences ? A: I will follow up with the Core Team and get a response posted with the transcript to MSDN  The Questions   [2010-3-30 12:57]: Thanks for the info Pev. I will follow up with the CETK experts here and get back to you. [2010-3-30 12:59]:   [2010-3-30 13:0]:   [2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; [2010-3-30 13:1]: [2010-3-30 13:1]: [2010-3-30 13:1]: [2010-3-30 13:3]: neo (Guest)[2010-3-30 11:37]: Hi all KellyG (Guest)[2010-3-30 11:37]: Hi KellyG (Guest)[2010-3-30 11:37]: I have a question unrelated to windows Ce embedded, can you please help me?? neo (Guest)[2010-3-30 11:38]: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals! c neo (Guest)[2010-3-30 11:38]: yes. post it. May be i cud give a try KellyG (Guest)[2010-3-30 11:38]: My Product key listed on my tower is not the product key I need for microsoft office, but that is the only product key listed. neo (Guest)[2010-3-30 11:39]: I hope this is a chat for windows embedded. please post ur queries in office forums KellyG (Guest)[2010-3-30 11:39]: it is but i could not find a forum for office neo (Guest)[2010-3-30 11:40]: I think moderators will help u out. @ davbo-msft: can u help this guy? neo (Guest)[2010-3-30 11:41]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? davbo-msft (Moderator)[2010-3-30 11:50]: Our chat today covers the topic of Windows Embedded CE! 1. This chat will last for one hour. During this hour, our Experts will respond to as many questions as they can. Please understand that there may be some questions we cannot respond to due to lack of information or because the information is not yet public. 2. We encourage you to submit questions for our Experts. To do so, type your questions in the send box, select the “ask the Experts” box and click SEND. Questions sent directly to the Guest Chat room will not be answered by the Experts, but we encourage other community members to assist. 3. We ask that you stay on topic for the duration of the chat. This helps the Guests and Experts follow the conversation more easily. We invite you to ask off topic questions after this chat is over, but not during. 4. Please abide by the Chat Code of Conduct. Chat code of conduct: <http://msdn.microsoft.com/chats/chatroom.aspx?ctl=hlp#Conduct>; Pev (Guest)[2010-3-30 11:54]: Evening! davbo-msft (Moderator)[2010-3-30 11:54]: Hello everyone this is Dave Boyce - I worked in the Multimedia area for Windows CE. neo (Guest)[2010-3-30 11:55]: hello dave neo (Guest)[2010-3-30 11:55]: The chat code of conduct link is not working! Pev (Guest)[2010-3-30 11:56]: Best be polite just in case then ;-) neo (Guest)[2010-3-30 11:56]: davbo-msft (Moderator)[2010-3-30 11:57]: I'll check out the issue w/ the link paolopat (Guest)[2010-3-30 12:0]: Hello davbo-msft (Moderator)[2010-3-30 12:0]: We are pleased to welcome our Experts for today’s chat. I will have them introduce themselves now. Chat will begin in a couple of minutes. <http://www.Microsoft.com/Embedded>; paolopat (Guest)[2010-3-30 12:3]: Hello Experts ! neo (Guest)[2010-3-30 12:3]: Welcome all! paolopat (Guest)[2010-3-30 12:3]: Q: I want to partition my NAND Flash device. One partition to use for hive ragistry and the other for the apps and data. The only way to do it is programmatically or setting some registry values ? neo (Guest)[2010-3-30 12:3]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? neo (Guest)[2010-3-30 12:5]: Q: My CPU is Intel celeron M processor 1Ghz. Pev (Guest)[2010-3-30 12:5]: neo: if your silicon has multiple general purpose timers, pick one that's not in use for the system timer / profiler and set it up to trigger irqs for your purpose. You can't guarantee hard realtime type responses though... GarySwalling (Guest)[2010-3-30 12:5]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? Pev (Guest)[2010-3-30 12:6]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? paolopat (Guest)[2010-3-30 12:6]: Q: But the operation for creating the partitions ? neo (Guest)[2010-3-30 12:6]: Q: If i need to implement it using interrupt handlers, What are all the files that I should look at? GPM (Guest)[2010-3-30 12:6]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? Jhony (Guest)[2010-3-30 12:7]: Q: I created a OS design with KITL and kernel debugger enabled. But I am unable to connect to the target for debugging. I am getting the following error when i try to connect with the device. PB Debugger Cannot initialize the Kernel Debugger. PB Debugger Debugger could not initialize connection. PB Debugger The Kernel Debugger is waiting to connect with target. PB Debugger The Kernel Debugger has been disconnected successfully. Charles (Guest)[2010-3-30 12:7]: What will be different in Windows Compact 7 from CE 6.0? neo (Guest)[2010-3-30 12:8]: Can I have the book's name please? kiefs_dev (Guest)[2010-3-30 12:8]: Q: hi everybody. I would like to know if there is something know about a bug in RTC API (VOIP), especially when using SIP. According the to the analysis with application verifyier there is a heap link in rtcdllmedia.dll. All of the unreleased chunks seem to have a size of 6560 bytes. paolopat (Guest)[2010-3-30 12:10]: Q: So...I have to modify file system code to create 2 partition at system startup ?!! I haven't understood.... neo (Guest)[2010-3-30 12:10]: Q: Do u mean ISR/IST implementation? How can i register an interrupt? What kind of interrupt should i register? neo (Guest)[2010-3-30 12:11]: Q: Can I have the book's name please? Charles (Guest)[2010-3-30 12:11]: Q: What will be different in Windows Compact 7 from CE 6.0? PaulT (Guest)[2010-3-30 12:11]: neo: I'd say that you really need the docs for YOUR BSP, not generic documents for BSPs in general. Each BSP may be architected differently. If you're using the CEPC BSP, then the documentation that comes with Platform Builder is a reasonable place to look. GPM (Guest)[2010-3-30 12:11]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? Elektrobit (Guest)[2010-3-30 12:12]: Q: Hi, we've problems with debugging of applications (= breakpoints in Platform Builder will be ignored) over KITL on Windows CE 5.0, if the PDB files are large (over 60MB). Are there any limitations to size of the PDB files? Jhony (Guest)[2010-3-30 12:15]: Q: I am using CE 6.0. There is no cesvchost process running in my system. alexquisi (Guest)[2010-3-30 12:15]: Q: Hi, I saw that the ATADISK is quite generic and des not have any optimizations. Do you have any advice to consider while tryin to improve the performance of it? Jhony (Guest)[2010-3-30 12:17]: Windows XP service pack 1 Jhony (Guest)[2010-3-30 12:17]: Q: sorry! Windows XP SP3 neo (Guest)[2010-3-30 12:19]: Q: The link for developing device drivers is not working. can u please check that? paolopat (Guest)[2010-3-30 12:20]: Q: I have a NAND Flash on my target device. On this flash I have the hive registry and an application.I have observed that when the NAND flash is fully, the system startup time is longer....is there a degradation of NAND use that influences the startup time ? Why ? Pev (Guest)[2010-3-30 12:20]: Q: When attempting to run the CETK cellcore tests the documentation states the pre-requisites include "stinger.ini", "ltk.ini" but windows CE doesn't provide these or document what they fully need to contain. Implicitly you also need "datatrans.xml" which isn't supplied. If you get around this error and steal these from Windows Mobile instead, when you try and run the CETK tests you get a data abort in radiometricsdll.dll. How should we invoke the cellcore parts of CETK? Pev (Guest)[2010-3-30 12:21]: Hi all, Pev (Guest)[2010-3-30 12:21]: oops Pev (Guest)[2010-3-30 12:21]: :-D Pev (Guest)[2010-3-30 12:24]: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Pev (Guest)[2010-3-30 12:25]: Q: Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. GPM (Guest)[2010-3-30 12:25]: Q: Writable bitmap, is there an example of the syntax? Pev (Guest)[2010-3-30 12:25]: Q: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. Pev (Guest)[2010-3-30 12:25]: sorry, messed up submission there! GPM (Guest)[2010-3-30 12:26]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? GPM (Guest)[2010-3-30 12:28]: Q: IXRVisualHost::GetHWND() exactly what I needed Thanks, PaulT (Guest)[2010-3-30 12:29]: GPM: You don't have to keep submitting the questions. The chat experts have an application that they're using to follow the chat and all Ask the Experts questions are logged. Jhony (Guest)[2010-3-30 12:29]: Q: I am getting this error only when I select the KdStub as the debugger in Target device connectivity. neo (Guest)[2010-3-30 12:30]: Q: ok. thanks for the book's link Pev (Guest)[2010-3-30 12:31]: Hm, did those two I submitted get picked up by anyone? neo (Guest)[2010-3-30 12:33]: Q: If I select Active KTIL, My OS doesn't boots. It says "loading NK.EXE at 0x<xxxxx> location" after that nothing comes in the debug log. PaulT (Guest)[2010-3-30 12:34]: Pev: PaulT (Guest)[2010-3-30 12:35]: Pev: I'm sure they did. The guys who are actually on the chat may not be experts in that part of things. That's usually the explanation when you don't get an answer in 10 minutes or so. Pev (Guest)[2010-3-30 12:36]: Ah, fair enough Susie (Guest)[2010-3-30 12:36]: My Outlook Express incoming mail is corrput. No ONE has been able to fix the problem, Dell or Norton. I have dial up I'm in a rural area Jhony (Guest)[2010-3-30 12:37]: Q: I have tried that and I am getting the same error. Pev (Guest)[2010-3-30 12:37]: Susie : Use Thunderbird instead :-D PaulT (Guest)[2010-3-30 12:37]: Susie: Sorry, but this chat is not about Windows, but Embedded (like what runs on a phone). Your best chance is to find a local expert or talk to your ISP. paolopat (Guest)[2010-3-30 12:37]: Q: what are the main differences between Object Store and RAM disk ? They are both in RAM...are there performance differences ? access differences ? Susie (Guest)[2010-3-30 12:38]: My computer knowlege is very limited, what is Thunderbird? Pev (Guest)[2010-3-30 12:38]: A different email client :-D neo (Guest)[2010-3-30 12:39]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug Susie (Guest)[2010-3-30 12:39]: Do I need to uninstall Outlook Express youngboyzie (Guest)[2010-3-30 12:39]: I need to start battery calibration for my new battery for my dell inspiron 1525 laptop and should be able to reach the BIOS screen by hitting f2 but this isnt working... help? Pev (Guest)[2010-3-30 12:39]: Nah, you can run it instead - you'll still need help from your ISP to configure it I expect Jhony (Guest)[2010-3-30 12:39]: Q: Both is happening via Ethernet. PaulT (Guest)[2010-3-30 12:40]: youngboyzie: You're off-topic. This is not a general chat for Windows and certainly not for Dell. You'll have to ask Dell how to get to setup; it's their machine. bill (Guest)[2010-3-30 12:41]: I lost spell check, how can i get et back neo (Guest)[2010-3-30 12:42]: Q: I didn't do that. I have to try. Jhony (Guest)[2010-3-30 12:43]: Q: Ok. I will do it then. bill (Guest)[2010-3-30 12:43]: Q: I lost spell check, how can i get it back PaulT (Guest)[2010-3-30 12:44]: bill: This isn't a general Windows chat. There are some Web forums that you might try. GarySwalling (Guest)[2010-3-30 12:45]: Q: Thanks, I found the Phone 7 presentation at http://live.visitmix.com/MIX10/Sessions/CL13 GPM (Guest)[2010-3-30 12:45]: Q: Is the Silverlight Animation "Spline" a BezierSpline? neo (Guest)[2010-3-30 12:46]: Q: ok. I'll do it. thanks Pev (Guest)[2010-3-30 12:46]: Whowever was asking about KITL connection : I've had this loads in the past. I think I started debugging last time by using wireshark to see what was happening on the network then setting up the OAL_ETHER and OAL_FUNC and OAL_VERBOSE as well as OAL_KITL flags to see what was actually happening in the driver.... Pev (Guest)[2010-3-30 12:47]: I'd generally make sure that you're testing though a 10baseT hub (instead of anything faster) and forcing Active KITL in polled mode too... neo (Guest)[2010-3-30 12:48]: Q: I disabled the firewall in my PC. Pev (Guest)[2010-3-30 12:50]: Q: I've got a platform (not developed by myself) where I2C bus support has to be provided through the OAL as the kernel needs to talk to devices such as the power management IC and gas gauge so a 'proper' I2C driver hanging off device manager isn't possible. This happens to be a polled driver, so obviously it hits the system hard when either under lots of traffic or an error condition occurs and the driver constantly polls. I originally thought that there was no straightforward way to make such code interrupt driven in the kernel (as it's a cludge) but I realised that that's exactly what ETHDBG drivers do. Is there any reason why I shouldn't have a go at implementing a similar mechanism for our kernel resident I2C driver? If not, are there any obvious pitfalls - I've not seen any other BSP's do this in the past... neo (Guest)[2010-3-30 12:51]: Q: I don't see a kitlcore.dll in my OS. is my debug image fails to load because of that? Pev (Guest)[2010-3-30 12:52]: Q: Hi masatos, I'm using Windows Embedded CE 6.0 with R3 and patched to feb 2010's QFE's (with it's associated CETK version) this is a machine with only CE 6.0 on (no conflicts with earlier CE or WM...) neo (Guest)[2010-3-30 12:54]: ok. Got it neo (Guest)[2010-3-30 12:54]: Q: ok. Got it Roundman (Guest)[2010-3-30 12:55]: Q: I am having trouble with my mouse, I have the microsoft wireless mobile mouse 3000, when I push the scroll button I am suppose to have autoscroll instead it shows other web pages,Can you help me out tell me what to do!!! Pev (Guest)[2010-3-30 12:55]: Hey neo, debugging kitl issues is really frustrating but dont lose heart :-) neo (Guest)[2010-3-30 12:55]: @ pev : u fixed the problem of KITL after that? neo (Guest)[2010-3-30 12:56]: I am getting the same error again and again. I even cleaned my environment and tried in a fresh PC. But didn't succeed yet Pev (Guest)[2010-3-30 12:56]: Well, eventually - my experiences probably won't help you as different platforms have different reasons for doing that neo (Guest)[2010-3-30 12:56]: I think so PaulT (Guest)[2010-3-30 12:58]: neo: Have you searched the old messages in microsoft.public.windowsce.platbuilder? It seems to me that there was a packet size situation where it was possible to have problems with KITL connections based on a setting on the PC. Google Groups, groups.google.com, Advanced Groups Search will allow you to search a single newsgroup or a set of newsgroups easily. GPM (Guest)[2010-3-30 12:58]: Q: Spline- bad link PaulT (Guest)[2010-3-30 12:58]: GPM: without the > at the end does it work? It seems to for me... neo (Guest)[2010-3-30 12:58]: But some times if i try to connect to the device again. The Image information is seen in the serial debug. what does that mean?Download BIN file information: ----------------------------------------------------- [0]: Base Address=0x220000 Length=0x18DAADC Received a broadcast message !CheckUDP: Not UDP (proto = 0x00000001) after this i am getting the old errors. PB debugger cannot initialize ... GPM (Guest)[2010-3-30 12:59]: Q: Sorry, got to tirm the ">" neo (Guest)[2010-3-30 12:59]: ok paul. I ll look into that. davbo-msft (Moderator)[2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; neo (Guest)[2010-3-30 13:1]: Q: I am unable to use the target control in my development environment. any ideas? Pev (Guest)[2010-3-30 13:1]: Sure, if KITL isn't connected target control won't work as it runs over kitl... neo (Guest)[2010-3-30 13:1]: ok .thanks pev neo (Guest)[2010-3-30 13:2]: yes. sysgen_shell is set to 1 neo (Guest)[2010-3-30 13:2]: Q: yes. sysgen_shell is set to 1 Marcelovk (Guest)[2010-3-30 13:2]: Q: Is there any way to extract the default command lines of the tests in CETK? I want to have it running unconnected from the desktop.   Copyright © 2010 – Bruce Eitman All Rights Reserved

    Read the article

< Previous Page | 3 4 5 6 7