  • some help required while working on java and cigwin together .

    - by Hippo
    Hello .. I am new to java and also cygwin . I do not have in detailed knowledge of both . I need some help.. I simple steps i will try to explain my problem. 1) I am working on tinyOS . its open source OS , used for wireless sensor networks. It provides java libraries to work on communication (PC to sensor) 2) I am working on windows xp environment through cigwin. 3) I am developing an application . THis application requires one java interface called "Serial Forwarder" , which is readily available in libraries provided. Previously i used to start this interface manually (by entering command *"java net.tinyos.sf.SerialForwarder ")*and then my application which uses this interface. But now i want to make my application independent . User need know about this background cygwin commands . 4) So in my java application i used "Runtime.getRuntime().exec( "java net.tinyos.sf.SerialForwarder)" . 5) This i neither giving any error nor starting the interface. Am I going on right way ? When i am using runtime execute command , how can i make sure that this command is called through cigwin interface ? Also .. if i want to write .bat file .. i which i can give commands which will be executed .. how can i make sure that those commands are given through cigwin .. and not through cmd.exe .. Please help . me .

    Read the article

  • Need a design pattern for representing multiple information sources

    - by hsmit
    I'm building a Java application that retrieves information from differing information sources. I'm using a sensor, a set of RecordStores and a few online web services. In the basic application all these resources are loaded by default. Some of these sources are directly read in a separate thread (load database, read sensor etc.). From this basic application some functions are started that use these sources. The classes that contain these functions (usually combining multiple sources information) are currently paramterized with a set of resources like this: AppPart a1 = new AppPart(source1, source2, source3); I could also do it like this AppPart a1 = new AppPart(this); ..where I need to make my sources public in order to read them. I'm also thinking about a kind of stage/collection to publish all sources on, e.g: public SourceCollectionStage sStage = new SourceCollectionStage(); and later: sStage.getSensor(); .. for example. What do you guys think is the best or most often used way to do this? Btw: the user interface is often implemented by the specific funtion classes, not by the main class. Should I do this in another way?

    Read the article

  • Some help required while working on Java and Cygwin together

    - by Hippo
    Hello .. I am new to java and also cygwin . I do not have in detailed knowledge of both . I need some help.. I simple steps i will try to explain my problem. 1) I am working on tinyOS . its open source OS , used for wireless sensor networks. It provides java libraries to work on communication (PC to sensor) 2) I am working on windows xp environment through cigwin. 3) I am developing an application . THis application requires one java interface called "Serial Forwarder" , which is readily available in libraries provided. Previously i used to start this interface manually (by entering command *"java net.tinyos.sf.SerialForwarder ")*and then my application which uses this interface. But now i want to make my application independent . User need know about this background cygwin commands . 4) So in my java application i used "Runtime.getRuntime().exec( "java net.tinyos.sf.SerialForwarder)" . 5) This i neither giving any error nor starting the interface. Am I going on right way ? When i am using runtime execute command , how can i make sure that this command is called through cigwin interface ? Also .. if i want to write .bat file .. i which i can give commands which will be executed .. how can i make sure that those commands are given through cigwin .. and not through cmd.exe .. Please help . me .

    Read the article

  • How can I get a static URL to a map image using the Google Static Maps API?

    - by Argote
    === BACKGROUND === Hello, so I've published a Web-App (still in "Beta") which uses the Flickr API to get information for the photos of a particular Flickr user and generates IPB code to post any of his/her images. While Flickr now gives you the IPB code to show the image and link back to the photo site directly on its site, my App also has the option of embeding the title, description, select EXIF data, location information, etc. into the post for the IPB forum. === PROBLEM === I've most recently added the option to integrate a Google Maps image of the photo's geolocation data into the post by using the Google Static Maps API. The problem is that the image URL I have is in the following form (including IPB [IMG] tags): [IMG]http://maps.google.com/maps/api/staticmap?zoom=16&size=600x600&maptype=hybrid&markers=19.387687,-99.251732&sensor=false[/IMG] Which shows this example image (In practice the image size is user selectable): However, some IPB forums seem to not support dyamic image URLs which gives me a broken image, I'd like to replace the [IMG]http://maps.google.com/maps/api/staticmap?zoom=16&size=600x600&maptype=hybrid&markers=19.387687,-99.251732&sensor=false[/IMG] with something like [IMG]http://maps.google.com/maps/api/staticmap/map0000001.png[/IMG] which should be supported by all IPB forums. Thanks in advance for your help. In case you're interested, the most recent "released" version of my Web-App can be found here: http://flickr.argote.mx/ (The changes I mention here are still on local development server).

    Read the article

  • MySql: Query multiple identical dynamic tables.

    - by JYelton
    I have a database with 500+ tables, each with identical structure, that contain historical data from sensors. I am trying to come up with a query that will locate, for example, all instances where sensor n exceeds x. The problem is that the tables are dynamic, the query must be able to dynamically obtain the list of tables. I can query information_schema.tables to get a list of the tables, like so: SELECT table_name FROM information_schema.tables WHERE table_schema = 'database_name'; I can use this to create a loop in the program and then query the database repeatedly, however it seems like there should be a way to have MySql do the multiple table search. I have not been able to make a stored procedure that works, but the examples I can find are generally for searching for a string in any column. I want to specifically find data in a specific column that exists in all tables. I admit I do not understand how to properly use stored procedures nor if they are the appropriate solution to this problem. An example query inside the loop would be: SELECT device_name, sensor_value FROM device_table WHERE sensor_value > 10; Trying the following does not work: SELECT device_name, sensor_value FROM ( SELECT table_name FROM information_schema.tables WHERE table_schema = 'database_name' ) WHERE sensor_value > 10; It results in an error: "Every derived table must have its own alias." The goal is to have a list of all devices that have had a given sensor value occur anywhere in their log (table). Ultimately, should I just loop in my program once I've obtained a list of tables, or is there a query structure that would be more efficient?

    Read the article

  • If we make a number every millisecond, how much data would we have in a day?

    - by Roger Travis
    I'm a bit confused here... I'm being offered to get into a project, where would be an array of certain sensors, that would give off reading every millisecond ( yes, 1000 reading in a second ). Reading would be a 3 or 4 digit number, for example like 818 or 1529. This reading need to be stored in a database on a server and accessed remotely. I never worked with such big amounts of data, what do you think, how much in terms of MBs reading from one sensor for a day would be?... 4(digits)x1000x60x60x24 ... = 345600000 bits ... right ? about 42 MB per day... doesn't seem too bad, right? therefor a DB of, say, 1 GB, would hold 23 days of info from 1 sensor, correct? I understand that MySQL & PHP probably would not be able to handle it... what would you suggest, maybe some aps? azure? oracle? ... Thansk!

    Read the article

  • Accelerometer stops delivering samples when the screen is off on Droid/Nexus One even with a WakeLoc

    - by William
    I have some code that extends a service and records onSensorChanged(SensorEvent event) accelerometer sensor readings on Android. I would like to be able to record these sensor readings even when the device is off (I'm careful with battery life and it's made obvious when it's running). While the screen is on the logging works fine on a 2.0.1 Motorola Droid and a 2.1 Nexus One. However, when the phone goes to sleep (by pushing the power button) the screen turns off and the onSensorChanged events stop being delivered (verified by using a Log.e message every N times onSensorChanged gets called). The service acquires a wakeLock to ensure that it keeps running in the background; but, it doesn't seem to have any effect. I've tried all the various PowerManager. wake locks but none of them seem to matter. _WakeLock = _PowerManager.newWakeLock(PowerManager.PARTIAL_WAKE_LOCK, "My Tag"); _WakeLock.acquire(); There have been conflicting reports about whether or not you can actually get data from the sensors while the screen is off... anyone have any experience with this on a more modern version of Android (Eclair) and hardware? This seems to indicate that it was working in Cupcake: http://groups.google.com/group/android-developers/msg/a616773b12c2d9e5 Thanks! PS: The exact same code works as intended in 1.5 on a G1. The logging continues when the screen turns off, when the application is in the background, etc.

    Read the article

  • Android - How to decide wether to run a Service in a separate Process?

    - by pableu
    I am working on an Android application that collects sensor data over the course of multiple hours. For that, we have a Service that collects the Sensor Data (e.g. Acceleration, GPS, ..), does some processing and stores them remotely on a server. Currently, this Service runs in a separate process (using android:service=":background" in the manifest). This complicates the communication between the Activities and the Service, but my predecessors created the Application this way because they thought that separating the Service from the Activities would make it more stable. I would like some more factual reasons for the effort of running a separate process. What are the advantages? Does it really run more stable? Is the Service less likely to be killed by the OS (to free up resources) if it's in a separate process? Our Application uses startForeground() and friends to minimize the chance of getting killed by the OS. The Android docs are not very specific about this, the mostly state that it depends on the Application's purpose ;-) TL;DR What are objective reasons to put a long-running Service in a separate process (in Android)?

    Read the article

  • Laptop LCD sometimes stops working on reboot. Please help.

    - by J Ringle
    I have a Gateway P-6831FX Laptop with Vista Ultimate. The Laptop LCD will sometimes not come on after I reboot the computer. I don't even close the lid and it happens. It isn't dim, it doesn't come on at all. No posting of CMOS (BIOS), nothing. Please note... this happens sometimes, not every time. Frustrating! When plugged into an external monitor, which works fine, Vista display properties can't even "sense" the laptop LCD. I try to enable the laptop LCD for dual display, turning on the laptop LCD, and it does nothing. It's like the laptop LCD is not even there. Manually taking a magnet in my hand to the laptop lid sensing switch (the sensor that turns off display/sleep mode when you close lid), sometimes causes the LCD backlight to "turn on" but not display any images. By "turn on" I mean I can see the screen backlight turn on to a 'dark gray' screen instead of pitch black. Subsequent reboot the laptop display is not working again! Here are the facts: Only happens at random and only after a reboot. Waking from Sleep mode isn't a problem. Pressing F4 function key for dual display does nothing when this happens. Closing lid doesn't seem to be related. (unless it is only after reboot.) using external magnet from laptop screen sensor sometimes triggers backlight to turn on but reboot back to square one with no LCD display. an external display always works fine. I have taken apart LCD, checked all wires and ribbons for loose connections or damage. I have replaced the Inverter. It doesn't seem to be heat related as I can put in sleep mode and resume fine when very hot. (external monitor works fine too). Sometimes the screen works fine as if there is not a problem at all. Even after a reboot... This is random. Any ideas out there? If it is a bad part... which one? The LCD seems to be fine. What are the odds of 2 bad inverters? The backlight is fine. The LCD wires/ribbons seem to be fine. I am at a loss. No warranty left and Gateway tech support is clueless. Thanks for any feedback that might help.

    Read the article

  • How can I disable the IR/Remote Control on an HP Laptop?

    - by Steve Rowe
    I've seen this happen on 2 different HP laptops now. If I try to use them in the same room as a Media Center, the MCE TV remote keeps sending commands to the laptop. This can do anything from wake it up and turn it on to just moving the selection around. There is no obvious way to disable the IR sensor or at least its response to the remote. Does anyone know how to do this?

    Read the article

  • My system show extremely hot processor temperature

    - by user34300
    I've build a small miniITX system with Pentium 4 processor. It works fine but there's extremely hot temperature is shown by the CPU sensor, around 120 C. Of course this is causing the fan run extremely fast as well making the whole system very loud. I tried to touch the CPU radiator but it is very cool so this should be some kind of error. Could you please give me an advice on how to troubleshoot this?

    Read the article

  • How to address a recurring low temperature error seen at every boot-up?

    - by GregC
    After updating to latest controller firmware, I started receiving the following error messages: LSI 2208 ROC: Temperature sensor below error threshold on enclosure 1 Sensors 5 thru 7 Is this something I should worry about, or is it a Red Herring? Details: I have a Sans Digital NexentaSTOR 24-disk JBOD enclosure connected to LSI 9286-8e RAID-on-Chip controller with two SAS cables. Seagate ES.2 3TB SAS hard drives populate every bay in the enclosure.

    Read the article

  • How can I monitor a Smart-UPS 2200 in PRTG?

    - by dasaybz
    This UPS is connected via a serial cable to a server. I am trying to get the temperature readings off of the sensor that is connected to the UPS and get them in PRTG. We were able to do this in the past and then when we changed the server out, we lost the settings. Does anyone have any info that might help? Thanks!!

    Read the article

  • How to turn a netbook into a powerful street navigator? Inexpensive options ?

    - by iceman
    I want to buy a USB powered GPS module together with a mapping software. Any recommendations and various options that I have ? Much like Garmin's MapSource software and GPS 18 USB: nRoute features an easy-to-use interface, making it intuitive to operate so you can focus on driving. It offers auto-routing and voice-prompting capabilities to virtually any address. The GPS 18 USB includes a 12 parallel channel, WAAS-enabled sensor with USB connection.

    Read the article

  • Galaxy Tab 3 producing continuous LightSensor error in LogCat

    - by Richard Tingle
    I am using a Galaxy Tab 3 as a test device for writing an android app. As such I'm interested in the output of the LogCat which is being filled with these error level messages. The device itself appears to work correctly, apps which rely on the light sensor correctly respond to it and the number in the error itself goes down if the light sensor is obscured. If I wasn't using it to develop apps I wouldn't even be aware of the issue but I believe it is an issue with the device itself not my app: simply plugging the tab 3 into the computer and using Eclipse - ADT to look at the LogCat without any app running leads to these errors being shown. I know I could filter the LogCat to ignore these errors but inconvenience aside; they concern me. A sample of the log cat is below (it generates errors continuously). This is on verbose so it includes some debug level (D/) messages as well as the error level messages (E/). How can I correct the device to no longer generate these errors. 06-11 10:08:45.789: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:45.992: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:46.195: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:46.398: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:46.601: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:46.804: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:47.007: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:47.210: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:47.414: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:47.617: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:47.820: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:48.023: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:48.039: D/dalvikvm(15201): GC_CONCURRENT freed 1947K, 17% free 16973K/20359K, paused 13ms+13ms, total 50ms 06-11 10:08:48.226: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:48.429: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 13 06-11 10:08:48.632: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 13 06-11 10:08:48.632: D/STATUSBAR-NetworkController(472): refreshSignalCluster: data=0 bt=false 06-11 10:08:48.835: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:49.039: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:49.242: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:49.445: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 13 06-11 10:08:49.632: D/STATUSBAR-NetworkController(472): refreshSignalCluster: data=0 bt=false 06-11 10:08:49.648: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 14 06-11 10:08:49.851: E/LightSensor(377): LightSensor::readEvents mPendingEvent.light = 13

    Read the article

  • Delegates and Events in C#

    - by hakanbilge
    Events and their underlying mechanism "Delegates" are very powerful tools of a developer and Event Driven Programming is one of the main Programming Paradigms. Its wiki definition is "event-driven programming or event-based programming is a programming paradigm in which the flow of the program is determined by events?i.e., sensor outputs or user actions (mouse clicks, key presses) or messages from other programs or threads." That means, your program can go its own way sequentially and in the case of anything that requires attention is done (when an event fires) by somebody or something, you can response it by using that event's controller method (this mechanism is like interrupt driven programming in embedded systems). There are many real world scenarios for events, for example, ASP.NET uses events to catch a click on a button or in your app, controller has notice of a change in UI by handling events exposed by view (in MVC pattern). Delegates in C# C# delegates correspond to function pointers in  [read more....]

    Read the article

  • Location, Orientation, and Writing a Custom Control with Mono for Android, .NET, and C#

    - by Wallym
    Like real estate, mobile is about location, location, location. That means that direction is an important item. And just as important is how this information is presented to the user. In Nov. 2011, we talked about building a user interface in Mono For Android. In this article, I'll expand a little bit on that by creating a compass that displays north. We'll use Android's built-in sensor support to determine the orientation of the device, then use a custom control to display North. The output will look like

    Read the article

  • Portal Turret Recreation an Amazing Clone of the Original [Video]

    - by Jason Fitzpatrick
    Last week Valve, the company behind the Portal series, received a crate containing a stunning replica of the iconic Portal turret sentry. Check out this video to see the turret in action. Valve explains the origin of the crate: On September 13th, 2012, Valve received another mysterious crate from WETA Workshop. Inside was a full-scale, articulated Portal turret, complete with a motion sensor. Once again, WETA Workshop’s gone far, far beyond our expectations to deliver something truly amazing. Thank you, WETA Workshop! If you’re ready to waste a little time geeking out over awesome props, designs, and other special FX goodies, you’ll definitely want to check out WETA’s site. [via Geeks Are Sexy] How To Create a Customized Windows 7 Installation Disc With Integrated Updates How to Get Pro Features in Windows Home Versions with Third Party Tools HTG Explains: Is ReadyBoost Worth Using?

    Read the article

  • What does "general purpose system" mean for Java SE Embedded?

    - by Majid Azimi
    The Oracle website says this about Java SE Embedded license: development is free, but royalties are required upon deployment on anything other than general purpose systems What does "general purpose system" mean here? We have a sensor network around the country. On each box we have installed, there is a micro controller based board that gets data from the environment and send data on serial port to a ARM based embedded board. On this board system there is a Java process which reads and submits data to our central server using JMS. Is this categorized as general purpose system? Sorry I'm asking this here. We are in Iran, there is no Oracle office here to ask.

    Read the article

  • How vibrations might effect Kinect depth measurements

    - by dreza
    I'm currently doing some research into development with the Microsoft Kinect product. My project manager has come up with a potential design for mounting the camera to do the capturing. However the solution means that the camera might be subject to vibrations as the platform it is on is directly connected to where the subjects will be moving. It was my thought that vibrations would effect the quality of the results, however I could not come up with a viable explanation as to why, other than it's the same as if you held a camera in your hand and your hand was shaking vs using a tripod. Do vibrations effect the depth measurements on a Kinect and if so how can I explain this in simple terms to my PM to help come up with a better design to attach the sensor to?

    Read the article

  • Ubuntu on Thinkpad Edge 11/13/14/15

    - by lasseespeholt
    I think a community wiki on problems (and solutions) when installing Ubuntu (10.10) on a Thinkpad Edge 11 would be nice (because I just got one ;)). I'll contribute with my own problems and solutions, and hope others will join too. Thinkwiki entry for the Edge 11 Known problems: No wifi-driver, solution: answer #1, answer #2 Fan is loud, even though it's on auto. No solution. Thinkfan is a possible solution, but correction values for sensors should be supplied (mapping sensors to specific areas). Also, one sensor is between -100C and +100C - maybe some kind of deactivation would help. FN keys stop working: see below. No sound on headphones: see below.

    Read the article

  • Ubuntu on Thinkpad Edge 11

    - by lasseespeholt
    Hi, I think a community wiki on problems (and solutions) when installing Ubuntu (10.10) on a Thinkpad Edge 11 would be nice (because I just got one ;)). I'll contribute with my own problems and solutions, and hope others will join too. Thinkwiki entry for the Edge 11 Known problems: No wifi-driver, solution: answer #1, answer #2 Fan is load, even though it's on auto. No solution. Thinkfan is a possible solution, but correction values for sensors should be supplied (mapping sensors to specific areas). Also, one sensor is between -100C and +100C - maybe some kind of deactivation would help.

    Read the article

  • My coworker created a 96 columns SQL table

    - by Eric
    Here we are in 2010, software engineers with 4 or 5 years or experience, still designing tables with 96 fracking columns. I told him it's gonna be a nightmare. I showed him that we have to use ordinals to interface MySQL with C#. I explained that tables with more columns than rows are a huge smell. Still, I get the "It's going to be simpler this way". What should I do? EDIT * This table contains data from sensors. We have sensor 1 with Dynamic_D1X Dynamic_D1Y [...] Dynamic_D6X Dynamic_D6Y [...]

    Read the article