Search Results

Search found 5204 results on 209 pages for 'max hui'.

Page 70/209 | < Previous Page | 66 67 68 69 70 71 72 73 74 75 76 77  | Next Page >

  • How to set up linux watchdog daemon with Intel 6300esb

    - by ACiD GRiM
    I've been searching for this on Google for sometime now and I have yet to find proper documentation on how to connect the kernel driver for my 6300esb watchdog timer to /dev/watchdog and ensure that watchdog daemon is keeping it alive. I am using RHEL compatible Scientific Linux 6.3 in a KVM virtual machine by the way Below is everything I've tried so far: dmesg|grep 6300 i6300ESB timer: Intel 6300ESB WatchDog Timer Driver v0.04 i6300ESB timer: initialized (0xffffc900008b8000). heartbeat=30 sec (nowayout=0) | ll /dev/watchdog crw-rw----. 1 root root 10, 130 Sep 22 22:25 /dev/watchdog | /etc/watchdog.conf #ping = 172.31.14.1 #ping = 172.26.1.255 #interface = eth0 file = /var/log/messages #change = 1407 # Uncomment to enable test. Setting one of these values to '0' disables it. # These values will hopefully never reboot your machine during normal use # (if your machine is really hung, the loadavg will go much higher than 25) max-load-1 = 24 max-load-5 = 18 max-load-15 = 12 # Note that this is the number of pages! # To get the real size, check how large the pagesize is on your machine. #min-memory = 1 #repair-binary = /usr/sbin/repair #test-binary = #test-timeout = watchdog-device = /dev/watchdog # Defaults compiled into the binary #temperature-device = #max-temperature = 120 # Defaults compiled into the binary #admin = root interval = 10 #logtick = 1 # This greatly decreases the chance that watchdog won't be scheduled before # your machine is really loaded realtime = yes priority = 1 # Check if syslogd is still running by enabling the following line #pidfile = /var/run/syslogd.pid Now maybe I'm not testing it correctly, but I would expecting that stopping the watchdog service would cause the /dev/watchdog to time out after 30 seconds and I should see the host reboot, however this does not happen. Also, here is my config for the KVM vm <!-- WARNING: THIS IS AN AUTO-GENERATED FILE. CHANGES TO IT ARE LIKELY TO BE OVERWRITTEN AND LOST. Changes to this xml configuration should be made using: virsh edit sl6template or other application using the libvirt API. --> <domain type='kvm'> <name>sl6template</name> <uuid>960d0ac2-2e6a-5efa-87a3-6bb779e15b6a</uuid> <memory unit='KiB'>262144</memory> <currentMemory unit='KiB'>262144</currentMemory> <vcpu placement='static'>1</vcpu> <os> <type arch='x86_64' machine='rhel6.3.0'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <cpu mode='custom' match='exact'> <model fallback='allow'>Westmere</model> <vendor>Intel</vendor> <feature policy='require' name='tm2'/> <feature policy='require' name='est'/> <feature policy='require' name='vmx'/> <feature policy='require' name='ds'/> <feature policy='require' name='smx'/> <feature policy='require' name='ss'/> <feature policy='require' name='vme'/> <feature policy='require' name='dtes64'/> <feature policy='require' name='rdtscp'/> <feature policy='require' name='ht'/> <feature policy='require' name='dca'/> <feature policy='require' name='pbe'/> <feature policy='require' name='tm'/> <feature policy='require' name='pdcm'/> <feature policy='require' name='pdpe1gb'/> <feature policy='require' name='ds_cpl'/> <feature policy='require' name='pclmuldq'/> <feature policy='require' name='xtpr'/> <feature policy='require' name='acpi'/> <feature policy='require' name='monitor'/> <feature policy='require' name='aes'/> </cpu> <clock offset='utc'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/mnt/data/vms/sl6template.img'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </disk> <controller type='usb' index='0'> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x2'/> </controller> <interface type='bridge'> <mac address='52:54:00:44:57:f6'/> <source bridge='br0.2'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:88:0f:42'/> <source bridge='br1'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/> </interface> <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target type='serial' port='0'/> </console> <watchdog model='i6300esb' action='reset'> <address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/> </watchdog> <memballoon model='virtio'> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </memballoon> </devices> </domain> Any help is appreciated as the most I've found are patches to kvm and general softdog documentation or IPMI watchdog answers.

    Read the article

  • regenerate the ID row in a MySQL Table with a Mysql's Script or PHP

    - by DomingoSL
    Hello, i have a database fill with information of the users who use my webpage. The table as many MySql tables have the ID parameters who is autoincrement. The issue is that when somebody eliminate his account from the site, in the database remain a jump in the sequence that i dont want cuz i have a script who fail if find some jump in the ID. Ex. ID Name PASS 1 Jhon 1234 2 Max 2233 3 Jorge 2232 If Max get out and a new user go in, this is what will happend. ID Name PASS 1 Jhon 1234 4 NewU 1133 3 Jorge 2232 So what is the best way to erase some body from the data base in order to avoid this isuue, or if is not a way, its posible to do a PHP or MySql script who eliminate all the contents in the ID row and regenerate it in order? Thanks A lot! sorry for my english

    Read the article

  • Port C's fread(&struct,....) to Python

    - by user287669
    Hey, I'm really struggling with this one. I'am trying to port a small piece of someone else's code to Python and this is what I have: typedef struct { uint8_t Y[LUMA_HEIGHT][LUMA_WIDTH]; uint8_t Cb[CHROMA_HEIGHT][CHROMA_WIDTH]; uint8_t Cr[CHROMA_HEIGHT][CHROMA_WIDTH]; } __attribute__((__packed__)) frame_t; frame_t frame; while (! feof(stdin)) { fread(&frame, 1, sizeof(frame), stdin); // DO SOME STUFF } Later I need to access the data like so: frame.Y[x][y] So I made a Class 'frame' in Python and inserted the corresponding variables(frame.Y, frame.Cb, frame.Cr). I have tried to sequentially map the data from Y[0][0] to Cr[MAX][MAX], even printed out the C struct in action but didn't manage to wrap my head around the method used to put the data in there. I've been struggling overnight with this and have to get back to the army tonight, so any immediate help is very welcome and appreciated. Thanks

    Read the article

  • SQL Server Group Concat with Different characters

    - by Molloch
    I have looked through a number of solutions to emulating "Group concat" functionality in SQL Server. I wanted to make a more human readable solution though and I can't work out how to do it. I have a view: ParentID | ChildName Which contains the records, for example: 1 | Max 1 | Jessie 2 | Steven 2 | Lucy 2 | Jake 3 | Mark I want to "Group Concat" these to get: 1 | Max and Jessie 2 | Steven, Lucy and Jake 3 | Mark So If there is only 1 child, just return name, if there are more than one, concat the last 2 with an ' and ' and all others with a ', '. I am a bit stuck on how to do this without resorting to CLR, which I don't want to do. I am happy with a function - but speed is an issue and how do I determine the child number so I can choose between ' and ', ', ' or ''?

    Read the article

  • How to recognize the touch of a non regular sprite image ?

    - by srikanth rongali
    I have a sprite and if it is touched the touch should be recognized. I used the coordinates to do so. I took the coordinates (min x, min y, max x , max y)of the sprite image. But The sprite image is not a rectangular shape. So, even if I touch the coordinates outside the sprite and inside the rectangular bounds the sprite is recognized. But for my application I need only the sprite to be recognized. So, I have to take only the coordinates of the sprite, but it is not regular shape. I am using CCSprite in my program. So, what can I do to for only the sprite to be selected ? Which classes should use for this? Thank You.

    Read the article

  • HTTP caching confusion

    - by Keith
    I'm not sure whether this is a server issue, or whether I'm failing to understand how HTTP caching really works. I have an ASP MVC application running on IIS7. There's a lot of static content as part of the site including lots of CSS, Javascript and image files. For these files I want the browser to cache them for at least a day - our .css, .js, .gif and .png files rarely change. My web.config goes like this: <system.webServer> <staticContent> <clientCache cacheControlMode="UseMaxAge" cacheControlMaxAge="1.00:00:00" /> </staticContent> </system.webServer> The problem I'm getting is that the browser (tested Chrome, IE8 and FX) doesn't seem to be caching the files as I'd expect. I've got the default settings (check for newer pages automatically in IE). On first visit the content downloads as expected HTTP/1.1 200 OK Cache-Control: max-age=86400 Content-Type: image/gif Last-Modified: Fri, 07 Aug 2009 09:55:15 GMT Accept-Ranges: bytes ETag: "3efeb2294517ca1:0" Server: Microsoft-IIS/7.0 X-Powered-By: ASP.NET Date: Mon, 07 Jun 2010 14:29:16 GMT Content-Length: 918 <content> I think that the Cache-Control: max-age=86400 should tell the browser not to request the page again for a day. Ok, so now the page is reloaded and the browser requests the image again. This time it gets an empty response with these headers: HTTP/1.1 304 Not Modified Cache-Control: max-age=86400 Last-Modified: Fri, 07 Aug 2009 09:55:15 GMT Accept-Ranges: bytes ETag: "3efeb2294517ca1:0" Server: Microsoft-IIS/7.0 X-Powered-By: ASP.NET Date: Mon, 07 Jun 2010 14:30:32 GMT So it looks like the browser has sent the ETag back (as a unique id for the resource), and the server's come back with a 304 Not Modified - telling the browser that it can use the previously downloaded file. It seems to me that would be correct for many caching situations, but here I don't want the extra round trip. I don't care if the image gets out of date when the file on the server changes. There are a lot of these files (even with sprite-maps and the like) and many of our clients have very slow networks. Each round trip to ping for that 304 status is taking about a 10th to a 5th of a second. Many also have IE6 which only has 2 HTTP connections at a time. The net result is that our application appears to be very slow for these clients with every page taking an extra couple of seconds to check that the static content hasn't changed. What response header am I missing that would cause the browser to aggressively cache the files? How would I set this in a .Net web.config for IIS7? Am I misunderstanding how HTTP caching works in the first place?

    Read the article

  • E4X in ActionScript help needed

    - by voipsecuritydigest.com
    Here is the XML How using E4X read values of nodes <status>??</status> and of node <invisible value="false"/> ? <?xml version="1.0" encoding="utf-8"?> <s:Application xmlns:fx="http://ns.adobe.com/mxml/2009" xmlns:s="library://ns.adobe.com/flex/spark" creationComplete="init()"> <fx:Declarations> <!-- Place non-visual elements (e.g., services, value objects) here --> </fx:Declarations> <fx:Script> <![CDATA[ var xml:XML = <iq type="result" id="ss-1"> <query status-min-ver="1" status-max="512" status-list-contents-max="5" status-list-max="3" xmlns="google:shared-status"> <status> ?? </status> <show> default </show> <status-list show="default"> <status> ?? </status> <status> ? </status> <status> ?? </status> </status-list> <status-list show="dnd"> <status> ?? </status> <status> dnd, i have bad mood </status> <status> showering </status> <status> ??_???¦ </status> <status> ? </status> </status-list> <invisible value="false"/> </query> </iq> public function init() { trace(xml.query.invisible.@value); } ]]> </fx:Script> </s:Application>

    Read the article

  • handling Concurrency in SQL SERVER 2005

    - by sameer
    Hi, I have one question for you, if you can answer and refer resource it will be great help. I have a scenario where i need to create a appointment slot and a serial no for each slot memberwise. ex: Member Id |App Slot # 1|1 1|2 2|1 2|2 1|3 what im doing is take the Max slot number,increamenting it and insert it memberwise. but the problem is concurrent user can create a slot when i take the max slot after that if any other user insert the slot the value that im working with is no more valid, how to over come this problem Thanks & Regards, Sameer

    Read the article

  • programming question

    - by shivam
    using System; using System.Data; using System.Collections.Generic; using System.ComponentModel; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.Data.SqlClient; namespace datasynchronization { public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void button1_Click(object sender, EventArgs e) { string connectString = @"Data Source=MOON\SQL2005;Initial Catalog=databaseA;Integrated Security=True"; using (var srcCon = new SqlConnection(connectString)) //connection to source table { srcCon.Open();//source table connection open SqlCommand cmd = new SqlCommand();// sqlobject for source table cmd.Connection = srcCon; string connectionString = @"Data Source=MOON\SQL2005;Initial Catalog=databaseB;Integrated Security=True"; using (var tgtCon = new SqlConnection(connectionString)) //connection to target table { tgtCon.Open(); //target table connection open SqlCommand objcmd1 = new SqlCommand();//sqlobject for target table objcmd1.Connection = tgtCon; objcmd1.CommandText = "SELECT MAX(date) FROM Table_2"; //query to findout the max date from target table var maxdate = objcmd1.ExecuteScalar(); // store the value of max date into the variable maxdate cmd.CommandText = string.Format("SELECT id,date,name,city,salary,region FROM Table_1 where date >'{0}'", maxdate); //select query to fetch rows from source table using (var reader = cmd.ExecuteReader()) { SqlCommand objcmd = new SqlCommand(); objcmd.Connection = tgtCon; objcmd.CommandText = "INSERT INTO Table_2(id,date,name,city,salary,region)VALUES(@id,@date,@name,@city,@salary,@region)"; objcmd.Parameters.Add("@id", SqlDbType.Int); objcmd.Parameters.Add("@date", SqlDbType.DateTime); objcmd.Parameters.Add("@name", SqlDbType.NVarChar); objcmd.Parameters.Add("@city", SqlDbType.NVarChar); objcmd.Parameters.Add("@salary", SqlDbType.Int); objcmd.Parameters.Add("@region", SqlDbType.Char); while (reader.Read()) { var order1 = reader[0].ToString(); var order2 = reader[1].ToString(); var order3 = reader[2].ToString(); var order4 = reader[3].ToString(); var order5 = reader[4].ToString(); var order6 = reader[5].ToString(); objcmd.Parameters["@id"].Value = order1; objcmd.Parameters["@date"].Value = order2; objcmd.Parameters["@name"].Value = order3; objcmd.Parameters["@city"].Value = order4; objcmd.Parameters["@salary"].Value = order5; objcmd.Parameters["@region"].Value = order6; objcmd.ExecuteNonQuery(); } } tgtCon.Close(); } srcCon.Close(); } } } } how can i organize the above written code in an efficient way?

    Read the article

  • Best Way to Generate Unique and consecutives numbers in Oracle

    - by RRUZ
    I need to generate unique and consecutive numbers (for use on an invoice), in a fast and reliable way. currently use a Oracle sequence, but in some cases generated numbers are not consecutive because of exceptions that may occur. I thought a couple of solutions to manage this problem, but neither of they convincing me. What solution do you recommend? Use a select max () SELECT MAX (NVL (doc_num, 0)) +1 FROM invoices Use a table to store the last number generated for the invoice. UPDATE docs_numbers SET last_invoice = last_invoice + 1 Another Solution?

    Read the article

  • Parallel Assignment operator in Ruby

    - by Bragaadeesh
    Hi, I was going through an example from Programming in Ruby book. This is that example def fib_up_to(max) i1, i2 = 1, 1 # parallel assignment (i1 = 1 and i2 = 1) while i1 <= max yield i1 i1, i2 = i2, i1+i2 end end fib_up_to(100) {|f| print f, " " } The above program simply prints the fibonacci numbers upto 100. Thats fine. My question here is when i replace the parallel assignment with something like this, i1 = i2 i2 = i1+i2 I am not getting the desired output. My question here is, is it advisable to use parallel assignments? (I come from Java background and it feels really wierd to see this type of assignment) One more doubt is : Is parallel assignment an operator?? Thanks

    Read the article

  • Problem with keyPress in Mozilla

    - by sudhansu
    I am usingtextarea to get some inputs. A label shows the updated chars left. It works fine in IE, but in FF 3.0, after reaching the max limit, it doesn't allow to delete or backspace key. I am using a javascript function on keypress event of the textarea. the javascript code is function checkLength() { var opinion = document.getElementById('opinion').value; if(opinion.length > 50) alert("You have reached the mas limit."); else document.getElementById('limit').innerHTML = 50 - opinion.length; } while on the page, i am using this <label id="limit">50 </label> <textarea id="opTxtArea" onkeypress="javascript:checkLength();"></textarea> Everything is working fine. The problem arises in FF, when the inputs reach the max limit, the message is displayed, but it doesn't allow to delete or backspace.

    Read the article

  • Android USB Host Communication

    - by Kip Russell
    I'm working on a project that utilizes the USB Host capabilities in Android 3.2. I'm suffering from a deplorable lack of knowledge and talent regarding USB/Serial communication in general. I'm also unable to find any good example code for what I need to do. I need to read from a USB Communication Device. Ex: When I connect via Putty (on my PC) I enter: >GO And the device starts spewing out data for me. Pitch/Roll/Temp/Checksum. Ex: $R1.217P-0.986T26.3*60 $R1.217P-0.986T26.3*60 $R1.217P-0.987T26.3*61 $R1.217P-0.986T26.3*60 $R1.217P-0.985T26.3*63 I can send the initial 'GO' command from the Android device at which time I receive an echo of 'GO'. Then nothing else on any subsequent reads. How can I: 1) Send the 'go' command. 2) Read in the stream of data that results. The USB device I'm working with has the following interfaces (endpoints). Device Class: Communication Device (0x2) Interfaces: Interface #0 Class: Communication Device (0x2) Endpoint #0 Direction: Inbound (0x80) Type: Intrrupt (0x3) Poll Interval: 255 Max Packet Size: 32 Attributes: 000000011 Interface #1 Class: Communication Device Class (CDC) (0xa) Endpoint #0 Address: 129 Number: 1 Direction: Inbound (0x80) Type: Bulk (0x2) Poll Interval (0) Max Packet Size: 32 Attributes: 000000010 Endpoint #1 Address: 2 Number: 2 Direction: Outbound (0x0) Type: Bulk (0x2) Poll Interval (0) Max Packet Size: 32 Attributes: 000000010 I'm able to deal with permission, connect to the device, find the correct interface and assign the endpoints. I'm just having trouble figuring out which technique to use to send the initial command read the ensuing data. I'm tried different combinations of bulkTransfer and controlTransfer with no luck. Thanks. I'm using interface#1 as seen below: public AcmDevice(UsbDeviceConnection usbDeviceConnection, UsbInterface usbInterface) { Preconditions.checkState(usbDeviceConnection.claimInterface(usbInterface, true)); this.usbDeviceConnection = usbDeviceConnection; UsbEndpoint epOut = null; UsbEndpoint epIn = null; // look for our bulk endpoints for (int i = 0; i < usbInterface.getEndpointCount(); i++) { UsbEndpoint ep = usbInterface.getEndpoint(i); Log.d(TAG, "EP " + i + ": " + ep.getType()); if (ep.getType() == UsbConstants.USB_ENDPOINT_XFER_BULK) { if (ep.getDirection() == UsbConstants.USB_DIR_OUT) { epOut = ep; } else if (ep.getDirection() == UsbConstants.USB_DIR_IN) { epIn = ep; } } } if (epOut == null || epIn == null) { throw new IllegalArgumentException("Not all endpoints found."); } AcmReader acmReader = new AcmReader(usbDeviceConnection, epIn); AcmWriter acmWriter = new AcmWriter(usbDeviceConnection, epOut); reader = new BufferedReader(acmReader); writer = new BufferedWriter(acmWriter); }

    Read the article

  • Create view or SP, only if the DB contains a pattern

    - by Randall Salas
    Hi all: I am working on a script, that needs to be run in many different SQL servers. Some of them, shared the same structure, in other words, they are identical, but the filegroups and the DB names are different. This is because is one per client. Anyway, I would like when running a script, If I chose the wrong DB, it should not be executed. I am trying to mantain a clean DB. here is my example, which only works for dropping a view if exists, but does not work for creating a new one. I also wonder how it would be for creating a stored procedure. Thx a lot. if exists (select * from dbo.sysobjects where id = object_id(N'[dbo].[ContentModDate]') and OBJECTPROPERTY(id, N'IsView') = 1) AND CHARINDEX('Content', DB_NAME()) 0 drop view [dbo].[ContentModDate] GO IF (CHARINDEX('Content', DB_NAME()) 0)BEGIN CREATE VIEW [dbo].[Rx_ContentModDate] AS SELECT 'Table1' AS TableName, MAX(ModDate) AS ModDate FROM Tabl1 WHERE ModDate IS NOT NULL UNION SELECT 'Table2', MAX(ModDate) AS ModDate FROM Table2 WHERE ModDate IS NOT NULL END END GO

    Read the article

  • CSS for mobile sometimes reverts back to original

    - by Jessie
    So most of the time my stylesheets appear properly. The standard/original one always works flawlessly, however it seems sometimes the mobile one is disregarded when looked at from a mobile device I have them designated as follows: <link runat="server" href="CustomStyleSheets/Menu.css" rel="stylesheet" type="text/css" /> <link href="CustomStyleSheets/mobile.css" rel="stylesheet" type="text/css" media="only screen and (max-device-width: 799px)" /> I'm using a Droid X to view the page, in portrait mode, so the device width shouldn't be exceeding the max-width specified above, but sometimes, randomly, it still reverts back to the original css page. Any way to keep it from doing so?

    Read the article

  • Illegal token on right side of ::

    - by Adam Haile
    I have the following template declaration: template <typename T> void IterTable(int& rIdx, std::vector<double>& rVarVector, const std::vector<T>& aTable, const T aValue, T aLowerBound = -(std::numeric_limits<T>::max()), //illegal token on right side of '::' shows here bool aLeftOpen = true) const; Which throws the illegal token error as noted, on the line with "-(std::numeric_limits::max())". I got this code from some old linux source that I'm trying to compile on Windows. Any idea what the issue is?

    Read the article

  • creating a JQuery function

    - by Russell Parrott
    Sorry to bother you guys & girls again on Christmas eve, but I need help creating a reusable JQuery function. I have "badly crafted" this set of code that all works. But I would really like to put it as a function so I don't have to keep repeating everything for each form. I am not too sure about how all the if statements can be combined etc. that is why I wrote it as it is. Any help much appreciated - Oh I suppose it could also be some kind of plugin but that might be the next step if I can understand how the function works. $(':input:visible').live('blur',function(){ if($(this).attr('required')) { if($(this).val() == '' ) { $(this).css({'background-color':'#FFEEEE' }); $(this).parent('form').children('input[type=submit]').hide(); $(this).next('.errormsg').html('OOPs ... '+$(this).prev('label').html()+' is required'); $(this).focus(); $(this).attr('placeholder').hide(); } else { $(this).css({'background-color':'#FFF' , 'border-color':'#999999'}); $(this).next('.errormsg').empty(); $(this).parent('form').children('input[type=submit]').show(); } } return false; }); $(':input[max]').live('blur',function(){ if($(this).attr('max') < parseInt($(this).val()) ){ $(this).next('.errormsg').html( 'OOPs ... the maximum value is '+$(this).attr('max') ); $(this).parent('form').children('input[type=submit]').hide(); $(this).focus(); } else {} return false; }); $(':input[min]').live('blur',function(){ if($(this).attr('min') > parseInt($(this).val()) ){ $(this).next('.errormsg').html( 'OOPs ... the minimum value is '+$(this).attr('min') ); $(this).parent('form').children('input[type=submit]').hide(); $(this).focus(); } else {} return false; }); $(':input[maxlength]').live('keyup',function(){ if($(this).val()==''){ } else { $(this).next('.errormsg').html( $(this).attr('maxlength')- $(this).val().length +' chars remaining'); } return false; }); As said, help much appreciated with one small (I hope) thing, how can I break out of any function IF there are no error messages to actually submit the form?

    Read the article

  • Nested query to find details in table B for maximum value in table A

    - by jpatokal
    I've got a huge bunch of flights travelling between airports. Each airport has an ID and (x,y) coordinates. For a given list of flights, I want to find the northernmost (highest x) airport visited. Here's the query I'm currently using: SELECT name,iata,icao,apid,x,y FROM airports WHERE y=(SELECT MAX(y) FROM airports AS a , flights AS f WHERE (f.src_apid=a.apid OR f.dst_apid=a.apid) ) This works beautifully and reasonably fast as long as y is unique, but fails once it isn't. What I'd want to do instead is find the MAX(y) in the subquery, but return the unique apid for the airport with the highest y. Any suggestions?

    Read the article

  • Which will be the best query OR there is an another one?

    - by serhan
    SELECT k.id,k.adsoyad, COUNT(DISTINCT(e.id)) as iletisimbilgisisay, COUNT(DISTINCT(f.id)) AS ilangonderensay, COUNT(DISTINCT(g.id)) AS emlaksahibisay, isNULL(MAX(eb.yonetici_kisi),0) AS yoneticiid FROM dbo.kisiler k LEFT OUTER JOIN dbo.emlaklar e ON e.iletisimbilgisi=k.id LEFT OUTER JOIN dbo.emlaklar f ON f.ilangonderen=k.id LEFT OUTER JOIN dbo.emlaklar g ON g.emlaksahibi=k.id LEFT OUTER JOIN dbo.emlakcibilgileri eb ON eb.yonetici_kisi=k.id GROUP BY k.id,k.adsoyad ORDER BY yoneticiid DESC, iletisimbilgisisay DESC, ilangonderensay DESC total execution time (above) 28 SELECT id,adsoyad, (select COUNT(id) FROM dbo.emlaklar WHERE iletisimbilgisi=k.id) AS iletisimbilgisisay, (select COUNT(id) FROM dbo.emlaklar WHERE emlaksahibi=k.id) AS emlaksahibisay, (select COUNT(id) FROM dbo.emlaklar WHERE ilangonderen=k.id) AS ilangonderensay, (Select isNULL(MAX(id),0) FROM dbo.emlakcibilgileri WHERE yonetici_kisi=k.id) AS yoneticiid FROM dbo.kisiler k total execution time 4 my tables are emlaklar: id int, ilangonderen int,iletisimbilgisi int,emlaksahibi int kisiler: id int,kisiadi emlakcibilgileri: id int,yonetici_kisi int,firma and ilangonderen,iletisimbilgisi,emlaksahibi,yonetici_kisi => kisiler.id

    Read the article

  • JBoss as a windows service. Where can i set the JAVA_OPTS?

    - by ikky
    hi. I'm running JBoss as a windows service, but i can't seem to find where i can configure the JAVA_OPTS to make it work properly. I need to set the Xms and the Xmx. I have tried to just run JBoss manually (run.bat) and in the same file i set the JAVA_OPTS= -Xms128m -Xmx512m. And that works. Here is my install.bat where i install the JBoss as a service: set JBOSS_CLASS_PATH=%JAVA_HOME%\lib\tools.jar;%JBOSS_HOME%\bin\run.jar rem copy /Y JavaService.exe D:\PROJECT\bin\JBossService.exe JBossService.exe -install JBoss %JAVA_HOME%\jre\bin\server\jvm.dll -Djava.class.path=%JBOSS_CLASS_PATH% -start org.jboss.Main -stop org.jboss.Shutdown -method systemExit -out %PROJECT_HOME%\log\JBoss_out.log -err %PROJECT_HOME%\log\JBoss_err.log -current D:\PROJECT\bin net start JBoss When i look at the info about JBoss Application Server (http://localhost:8080/web-console/) i see this info: JVM Environment Free Memory: 9 MB Max Memory: 63 MB Total Memory: 63 MB And i MUST have more Max Memory. Does anybody know where i can set the JAVA_OPTS when running JBoss as a service?

    Read the article

  • Capitalize Words in PHP with custom delimitor

    - by Paulie
    Hey guys, i need a method to capitalize every first letter of a word. This is what i got so far and it is working for almost every string...but it fails on this one "WELLNESS & RENOMME". // method in stringModify Class function capitalizeWords($words, $charList) { $capitalizeNext = true; for ($i = 0, $max = strlen($words); $i < $max; $i++) { if (strpos($charList, $words[$i]) !== false) { $`capitalizeNext` = true; } else if ($capitalizeNext) { $capitalizeNext = false; $words[$i] = strtoupper($words[$i]); } } return $words; } // Calling method $stringModify->capitalizeWords("WELLNESS & RENOMME", " -&"); I hope someone can help me out...i tried for 1,5 hours now and don't have a clue. Thanks in advance for any tips or hints. Greetz Paulie

    Read the article

  • How to stream semi-live audio over internet

    - by Thomas Tempelmann
    I want to write something like Skype, i.e. I have a constant audio stream on one computer and then recompress it in a format that's suitable for a latent internet connection, receive it on the other end and play it. Let's also assume that the internet connection is fairly modern and fast, i.e. DSL or alike, no slow connections over phone and such. The involved computers will also be rather modern (Dual Core Intel CPUs at 2GHz or more). I know how to handle the audio on the machines. What I don't know is how to transmit the audio in an efficient way. The challenges are: I'd like get good audio quality across the line. The stream should be received without drops. The stream may, however, be received with a little delay (a second delay is acceptable). I imagine that the transport software could first determine the average (and max) latency, then start the stream and tell the receiver to wait for that max latency before starting to play the audio. With that, if the latency doesn't get any higher, the entire stream will be playable on the other side without stutter or drops. If, due to unexpected IP latencies or blockages, the stream does get cut off, I want to be able to notice this so that I can take actions (e.g. abort the stream) and eventually start a new transmission. What are my options if I want do use ready-made software for the compression and tranmission? I have no intention to write my own audio compression engine, really. OTOH, I plan to sell the solution in a vertical market, meaning I can afford a few dollars of license fees per copy, but not $100s. I guess the simplest solution would be to just open a TCP stream, send a few packets back and forth to determine their running time (or even use UDP for that), then use the results as the guide for my max latency value, then simply fire the audio data in its raw form (uncompressed 16 bit stereo), along with a timing code over the TCP connection. The receiver reads the data and plays it with the pre-determined delay. That might just work with the type of fast connection I expect. I just wonder if there are better solutions to reach this goal, with better performance (lower latency) and less data (compressed). BTW, I first try to implement this on OS X, but might want to do it on Windows, too, if it proves successful.

    Read the article

  • proper Django ORM syntax to make this code work in MySQL

    - by gtujan
    I have the following django code working on an sqlite database but for some unknown reason I get a syntax error if I change the backend to MySQL...does django's ORM treat filtering differently in MySQL? def wsjson(request,imei): wstations = WS.objects.annotate(latest_wslog_date=Max('wslog__date'),latest_wslog_time=Max('wslog__time')) logs = WSLog.objects.filter(date__in=[b.latest_wslog_date for b in wstations],time__in=[b.latest_wslog_time for b in wstations],imei__exact=imei) data = serializers.serialize('json',logs) return HttpResponse(data,'application/javascript') The code basically gets the latest logs from WSlog corresponding to each record in WS and serializes it to json. Models are defined as: class WS(models.Model): name = models.CharField(max_length=20) imei = models.CharField(max_length=15) description = models.TextField() def __unicode__(self): return self.name class WSLog(models.Model): imei = models.CharField(max_length=15) date = models.DateField() time = models.TimeField() data1 = models.DecimalField(max_digits=8,decimal_places=3) data2 = models.DecimalField(max_digits=8,decimal_places=3) WS = models.ForeignKey(WS) def __unicode__(self): return self.imei

    Read the article

  • tricky SQL when joining

    - by Erik
    I've two tables, shows and objects. I want to print out the latest objects, and the shownames for them. Right now I'm doing it this way: SELECT MAX(objects.id) as max_id, shows.name, shows.id FROM shows, objects WHERE shows.id = objects.showId GROUP BY shows.name however, if I also want to fetch the episode of the object I can't put it like SELECT object.episode [...], because then wont automatically select the object which is MAX(objects.id), so my question is how to do that? If you haven't already figured out my tables they're like this: Shows id name and also: Objects id name episode season showId Using MySQL. Thanks!

    Read the article

< Previous Page | 66 67 68 69 70 71 72 73 74 75 76 77  | Next Page >