  • Bluetooth not found on BCM43228

    - by TK Kocheran
    I've got a Broadcom BCM43228 mPCIe card which came with my motherboard (ASUS ROG Maximus V Extreme, can't seem to find a link to what the card is) which is working great for WiFi right now, but I can't detect the Bluetooth hardware onboard. In Windows, I have full Bluetooth 4.0 support. $ lspci 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:14.0 USB controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579V Gigabit Network Connection (rev 04) 00:1a.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) 00:1c.4 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 5 (rev c4) 00:1c.6 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 7 (rev c4) 00:1c.7 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 8 (rev c4) 00:1d.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Panther Point 6 port SATA Controller [AHCI mode] (rev 04) 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation Device 1189 (rev a1) 01:00.1 Audio device: NVIDIA Corporation Device 0e0a (rev a1) 0d:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 0e:00.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:01.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:04.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:05.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:06.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:07.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:08.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:09.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 10:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 12:00.0 SATA controller: ASMedia Technology Inc. ASM1062 Serial ATA Controller (rev 01) 15:00.0 Network controller: Broadcom Corporation BCM43228 802.11a/b/g/n 17:00.0 SATA controller: ASMedia Technology Inc. ASM1062 Serial ATA Controller (rev 01) The key line seems to be: 15:00.0 Network controller: Broadcom Corporation BCM43228 802.11a/b/g/n If I try to detect the Bluetooth card, I don't see anything: $ hcitool dev Devices: rfkill list all: Output lspci: Output lsusb: Output I finally found the card with usb-devices: T: Bus=01 Lev=02 Prnt=02 Port=00 Cnt=01 Dev#= 3 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=ff(vend.) Sub=01 Prot=01 MxPS=64 #Cfgs= 1 P: Vendor=0b05 ProdID=17b5 Rev=01.12 S: Manufacturer=Broadcom Corp S: Product=BCM20702A0 S: SerialNumber=############ C: #Ifs= 4 Cfg#= 1 Atr=e0 MxPwr=0mA I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=01 Prot=01 Driver=(none) I: If#= 1 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=01 Prot=01 Driver=(none) I: If#= 2 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none) I: If#= 3 Alt= 0 #EPs= 0 Cls=fe(app. ) Sub=01 Prot=01 Driver=(none) I've heard that this card needs to have firmware injected into it in order to function. If that's the case, how do I do it?

    Read the article

  • Long 'Wait' Time for three php/CSS files. Is something blocking them?

    - by William Pitcher
    I have been speed optimizing a Wordpress site to little effect. There are three files CSS-related php files from the Wordpress theme that are delaying page loads on the site. One of the three files is basically one line of custom CSS from the custom CSS feature in the theme. You can see what I am talking about with this Pingdom speed test: The yellow is 'Wait'. There are no slow items in the cut-off portion of the image. The full results are here: Pingdom Results Page 1. Any thoughts on what might be causing this? I understand that I have blocking CSS or JS files, but I don't see anything that would be causing that long of a wait. When I ran the P3 Plugin Profiler, Wordpress and all plugins appeared fine -- it is the theme that is taking all the time. GTmetrix recommends avoiding dynamic queries. I assume all the ver=3.61 references are to the version of Wordpress (which I am using). I noticed that my Wordpress sites using other themes don't make this query (at least not over and over). 2. Is this typical coding practice? 3. How much negative impact do these query-strings have -- a little or a lot? I tried searching for similar questions here, please excuse me if I missed something. Sometimes, I know just enough to be dangerous.

    Read the article

  • Binary to Ascii and back again

    - by rross
    I'm trying to interface with a hardware device via the serial port. When I use software like Portmon to see the messages they look like this: 42 21 21 21 21 41 45 21 26 21 29 21 26 59 5F 41 30 21 2B 21 27 42 21 21 21 21 41 47 21 27 21 28 21 27 59 5D 41 32 21 2A 21 28 When I run them thru a hex to ascii converter the commands don't make sense. Are these messages in fact something different than hex? My hope was to see the messages the device is passing and emulate them using c#. What can I do to find out exactly what the messages are?

    Read the article

  • Why not port Linux kernel to Common Lisp?

    - by rplevy
    Conventional wisdom states that OS kernels must be written in C in order to achieve the necessary levels of performance. This has been the justification for not using more expressive high level languages. However, for a few years now implementations of Common Lisp such as SBCL have proven to be just as performant as C. What then are the arguments against redoing the kernel in a powerfully expressive language, namely Common Lisp? I don't think anyone (at least anyone who knows what they are talking about) could argue against the fact that the benefits in transparency and readability would be tremendous, not to mention all the things that can't be done in C that can be done in Lisp, but there may be implementation details that would make this a bad idea.

    Read the article

  • Visual Studio 2008 Web Project error: Unable to start program http://localhost:port

    - by JookyDFW
    I am re-hashing this question because I have looked at over 50 threads in different forums and have not been able to get a resolution to my problem. Here are the specs: Windows XP SP3, Visual Studio 2008 SP1, .NET 3.5, ASP. NET MVC 2 project, IE 7 (was IE 8) Up until a few days ago I was not having any issues. It is now happening on any solution that I try to debug. I start a debug session (F5), the solution rebuilds, a VS development web server starts and then I get this error: Unable to start program http://localhost:2012/ If I open a web browser and enter the URL the application loads up. I had upgraded to IE 8 a few weeks ago and read there may be some issues so it has been uninstalled and I am currently on IE 7. Also, while IE 8 was installed I had switched my default browser to Firefox but my current default broweser is now IE7. I have reveiewed the threads on this site and others and have not been able to fix the issue. Any help would be appreciated.

    Read the article

  • Ruby SerialPorts Gem

    - by Seth Archer
    Using Ruby SerialPorts Gem to interact with hardware. When I write a byte array to the hardware using a program called "Serial Port Monitor" the hardware responds correctly. However, when I write the same byte array using ruby it doesn't work unless I do a read request just before the write request. This device doesn't respond correctly with this sp = SerialPort.new(args) sp.write [200.chr, 30.chr, 6.chr, 5.chr, 1.chr, 2.chr, 0.chr, 244.chr] But it does if I add a read request before the write. Like this sp SerialPort.new(args) sp.read sp.write [200.chr, 30.chr, 6.chr, 5.chr, 1.chr, 2.chr, 0.chr, 244.chr] This works, but I'm at a loss as to why. I should also add that the first snippet does work occasionally maybe 1/10 of the time.

    Read the article

  • CherryPy sessions for same domain, different port

    - by detly
    Consider the script below. It will launch two subprocesses, each one a CherryPy app (hit Ctrl+C or whatever the KeyboardInterrupt combo is on your system to end them both). If you run it with CP 3.0 (taking care to change the 3.0/3.1 specific lines in "StartServer"), then visit: http://localhost:15002/ ...you see an empty dict. Then visit: http://localhost:15002/set?val=10 http://localhost:15002/ ...and you see the newly populated dict. Then visit: http://localhost:15012/ ...and go back to http://localhost:15002/ ...and nothing has changed. If you try the same thing with CP 3.1 (remember the lines in "StartServer"!), when you get to the last step, the dict is now empty. This happens in Windows and Debian, Python 2.5 and 2.6. You can try all sorts of things: changing to file storage, separating the storage paths... the only difference it makes is that the sessions might get merged instead of erased. I've read another post about this as well, and there's a suggestion there to put the session tools config keys in the app config rather than the global config, but I don't think that's relevant to this usage where the apps run independently. What do I do to get independent CherryPy applications to NOT interfere with each other? Note: I originally asked this on the CherryPy mailing list but haven't had a response yet so I'm trying here. I hope that's okay. import os, os.path, socket, sys import subprocess import cgi import cherrypy HTTP_PORT = 15002 HTTP_HOST = "127.0.0.1" site1conf = { 'global' : { 'server.socket_host' : HTTP_HOST, 'server.socket_port' : HTTP_PORT, 'tools.sessions.on' : True, # 'tools.sessions.storage_type': 'file', # 'tools.sessions.storage_path': '1', # 'tools.sessions.storage_path': '.', 'tools.sessions.timeout' : 1440}} site2conf = { 'global' : { 'server.socket_host' : HTTP_HOST, 'server.socket_port' : HTTP_PORT + 10, 'tools.sessions.on' : True, # 'tools.sessions.storage_type': 'file', # 'tools.sessions.storage_path': '2', # 'tools.sessions.storage_path': '.', 'tools.sessions.timeout' : 1440}} class Home(object) : def __init__(self, key): self.key = key @cherrypy.expose def index(self): return """\ <html> <body>Session: <br>%s </body> </html> """ % cgi.escape(str(dict(cherrypy.session))) @cherrypy.expose def set(self, val): cherrypy.session[self.key.upper()] = val return """\ <html> <body>Set %s to %s</body> </html>""" % (cgi.escape(self.key), cgi.escape(val)) def StartServer(conf, key): cherrypy.config.update(conf) print 'Starting server (%s)' % key cherrypy.tree.mount(Home(key), '/', {}) # Start the web server. #### 3.0 # cherrypy.server.quickstart() # cherrypy.engine.start() #### #### 3.1 cherrypy.engine.start() cherrypy.engine.block() #### def Main(): # Start first webserver proc1 = subprocess.Popen( [sys.executable, os.path.abspath(__file__), "1"]) proc2 = subprocess.Popen( [sys.executable, os.path.abspath(__file__), "2"]) proc1.wait() proc2.wait() if __name__ == "__main__": print sys.argv if len(sys.argv) == 1: # Master process Main() elif(int(sys.argv[1]) == 1): StartServer(site1conf, 'magic') elif(int(sys.argv[1]) == 2): StartServer(site2conf, 'science') else: sys.exit(1)

    Read the article

  • MacPorts manual port location

    - by gok
    I am installing one library for python from MacPorts. But macports version is older than actual development svn version. Is it possible to specify a custom location for installation in MacPorts so I could install latest library from the developer's site?

    Read the article

  • Where to get apache poi port for .net

    - by Nassign
    I would like to know if there is a website where I could download the Apache POI ported for .net? I already found this link in the web http://www.apache.org/~avik/dist/poi-2.5.1-dev-20040708.dll But the version of apache poi now is 3.6, I was wondering if there is a latest version out there? Does the apache foundation support such porting? I already tried to search the apache website too with no avail. As for using Microsoft library, the excel interopt is not that good for concurrent processing like a web backend. If I use the DocumentFormat.OpenXML library, I have a limitation of creating office 2007 document only.

    Read the article

  • org.smslib port in use exception

    - by danar jabbar
    I am trying to create web application to send sms by gsm modem in JSP first I put destination mobile number and sms text in url and get by request.getparameter and first message sent with no problem but when send a message again by referenshing the same page i get this exception: org.smslib.GatewayException: Comm library exception: java.lang.RuntimeException: gnu.io.PortInUseException: org.smslib at org.smslib.modem.SerialModemDriver.connectPort(SerialModemDriver.java:102) at org.smslib.modem.AModemDriver.connect(AModemDriver.java:114) at org.smslib.modem.ModemGateway.startGateway(ModemGateway.java:189) at org.smslib.Service$1Starter.run(Service.java:276) I tried to stop gateway and stop service but no hope My code: public boolean sendMessage(String strMobileNo,String strSMSText) { try { OutboundMessage outboundMessage=new OutboundMessage(); SMS message=new SMS(); SerialModemGateway gateway = new SerialModemGateway("modem.com1", "COM12", 9600, "Huawie", "EF200"); gateway.setInbound(true); gateway.setOutbound(true); gateway.setSimPin("0000"); gateway.setSmscNumber("+9647701144010"); Service.getInstance().setOutboundMessageNotification(message); Service.getInstance().addGateway(gateway); Service.getInstance().startService(); outboundMessage.setText(strSMSText); outboundMessage.setRecipient(strMobileNo); outboundMessage.setEncoding(Message.MessageEncodings.ENCUCS2); //outboundMessage.setDeliveryDelay(5000); Service.getInstance().sendMessage(outboundMessage); System.out.println(outboundMessage); gateway.stopGateway(); Service.getInstance().stopService(); Thread.sleep(10000); return true; } catch (Exception e) { e.printStackTrace(); return false; } }

    Read the article

  • I want to port my delicious bookmarks to my website

    - by puneet
    I started building a app that will automatically download my delicious bookmarks, and save to a database, so they I can view them on my own website in my favoured format. I am forced to use oAuth, as I have a yahoo id to login to delicious. The problem is I am stuck at the point where oAuth requires a user to manually go and authenticate. Is there a code/ guidelines available anywhere I can follow? All I want is a way to automatically save my bookmarks to my database. Any help is appreciated. I can work on java, .net and php. Thanks.

    Read the article

  • Port a live system from App Engine Helper to App Engine Patch

    - by Alexander
    I am running a live system that is currently serving about 20K pages a day which is based on App Engine Helper (Python) with session support provided by AppEngine utilities. One problem that I have been having is that sessions are occasionally randomly logging out. I would like to try using the App Engine Patch, since it has "native" django session support, but I am worried that this is possibly going to be like doing a brain transplant. Specifically, current database models are all inhereted from BaseModel provided by the App Engine Helper. While, App Engine Patch does not have this inheritance. Does anyone know if it is possible to migrate a live system from App Engine Helper to App Engine Patch? If so, do you have any advice or warnings that I should heed, before attempting this transition? Thank you and kind regards Alex

    Read the article

  • Communication with HyperTerminal [ QT and WINApi ]

    - by javaAmator
    Hi! I write program to communicate with modem (it useing Hayes commands) and this is working. GUI is programmed with QT, but communication with COM port is write with winapi library. I have problem when I want to send with my program message from one computer to another, i can't send Polish chars (they are repleaced by '?'), how can I fix it ? Does anyone have idea ?? And I have one more problem, I can't send message from my program to Microsoft HyperTerminal, HyperTerminal receive something, but not that what I send. Thx for any help :) Important pieces of code: Connect with port: portHandle = CreateFile (portName, GENERIC_WRITE | GENERIC_READ, 0, NULL, OPEN_EXISTING, 0, NULL); GetCommState (portHandle, &dcb); switch(ui->comboBox->currentIndex()) { case 0 : dcb.BaudRate=CBR_110; break; case 1 : dcb.BaudRate=CBR_300; break; case 2 : dcb.BaudRate=CBR_600; break; case 3 : dcb.BaudRate=CBR_1200; break; case 4 : dcb.BaudRate=CBR_2400; break; case 5 : dcb.BaudRate=CBR_4800; break; case 6 : dcb.BaudRate=CBR_9600; break; case 7 : dcb.BaudRate=CBR_14400; break; case 8 : dcb.BaudRate=CBR_19200; break; case 9 : dcb.BaudRate=CBR_38400; break; case 10 : dcb.BaudRate=CBR_56000; break; case 11 : dcb.BaudRate=CBR_57600; break; case 12 : dcb.BaudRate=CBR_115200; break; case 13 : dcb.BaudRate=CBR_128000; break; case 14 : dcb.BaudRate=CBR_256000; break; } dcb.fBinary = TRUE; dcb.fParity = TRUE; dcb.fOutxCtsFlow = FALSE; dcb.fOutxDsrFlow = FALSE; dcb.fDtrControl = DTR_CONTROL_ENABLE; dcb.fDsrSensitivity = FALSE; dcb.fTXContinueOnXoff = TRUE; dcb.fOutX = FALSE; dcb.fInX = FALSE; dcb.fErrorChar = FALSE; dcb.fNull = FALSE; dcb.fRtsControl = RTS_CONTROL_ENABLE; dcb.fAbortOnError = FALSE; //dcb.ByteSize = dataBits; dcb.DCBlength = sizeof (DCB); switch(ui->comboBox_3->currentIndex()) { case 1 : dcb.Parity = EVENPARITY; break; case 3 : dcb.Parity = MARKPARITY; break; case 2 : dcb.Parity = ODDPARITY; break; case 4 : dcb.Parity = SPACEPARITY; break; case 0 : dcb.Parity = NOPARITY; break; } switch (ui->comboBox_4->currentIndex()) { case 0 : dcb.StopBits = ONESTOPBIT; break; case 1 : dcb.StopBits = ONE5STOPBITS;break; case 2 : dcb.StopBits = TWOSTOPBITS; break; } switch (ui->comboBox_2->currentIndex()) { case 0 : dcb.ByteSize = 5; break; case 1 : dcb.ByteSize = 6;break; case 2 : dcb.ByteSize= 7; break; case 3 : dcb.ByteSize = 8; break; } SetCommState (portHandle, &dcb); GetCommTimeouts (portHandle, &CommTimeouts); CommTimeouts.ReadIntervalTimeout = MAXDWORD; CommTimeouts.ReadTotalTimeoutMultiplier = 0; CommTimeouts.ReadTotalTimeoutConstant = 0; CommTimeouts.WriteTotalTimeoutMultiplier = 10; CommTimeouts.WriteTotalTimeoutConstant = 1000; SetCommTimeouts (portHandle, &CommTimeouts); Send MSG: void MainWindow::Send(char c) { do {WriteFile(portHandle, &c, 1, &cbWritten, NULL); } while (!(cbWritten)); } void MainWindow::on_pushButton_clicked() { QString str = ui->lineEdit->text(); std::string str2; ui->lineEdit->clear(); str2 = str.toStdString(); for(int i=0; i < str2.size();i++) { Send(str2[i]); //qDebug()<< str2[i]; } Send(char(13)); } Receive MSG: void ReaderThread::run() { char c; while(1) { c = Receive(); if(c==13) { emit insertPlainText("\n"); } else { emit insertPlainText(QString(c)); } } } char ReaderThread::Receive() { char c; do{ ReadFile(portHandle, &c, 1, &cbRead, NULL); } while (!(cbRead)); return c; }

    Read the article

  • Programmatically Set Proxy Address, Port, User, Password throught Windows Registry

    - by Fábio Antunes
    I'm writing a small C# application that will use Internet Explorer to interact with a couple a websites, with help from WatiN. However, it will also require from time to time to use a proxy. I've came across Programmatically Set Browser Proxy Settings in C#, but this only enables me to enter a proxy address, and I also need to enter a Proxy username and password. How can I do that? Note: It doesn't matter if a solution changes the entire system Internet settings. However, I would prefer to change only IE proxy settings (for any connection). The solution has to work with IE8 and Windows XP SP3 or higher. I'd like to have the possibility to read the Proxy settings first, so that later I can undo my changes. EDIT With the help of the Windows Registry accessible through Microsoft.Win32.RegistryKey, i was able to apply a proxy something like this: RegistryKey registry = Registry.CurrentUser.OpenSubKey("Software\\Microsoft\\Windows\\CurrentVersion\\Internet Settings", true); registry.SetValue("ProxyEnable", 1); registry.SetValue("ProxyServer", "127.0.0.1:8080"); But how can i specify a username and a password to login at the proxy server? I also noticed that IE doesn't refresh the Proxy details for its connections once the registry was changed how can i order IE to refresh its connection settings from the registry? Thanks

    Read the article

  • Restrict RDP port based on a Dynamic DNS

    - by webnoob
    Hi All, I want to set a restriction on my firewall (windows firewall on windows 2008) to only allow connections from a certain dynamic DNS. Is this possible? The reason I ask is that this would allow us to just change the IP on the dynamic DNS if our IP changes and means we won't get locked out of RDP. This also allows me to RDP in from other locations that have IP's that are not static by just changing the IP against the DNS. Any ideas. Thanks in advance.

    Read the article

  • Java RS232 Comm on Vista-64 bit

    - by DD
    We have a Java application which needs to communicate with a peripheral device over Virtual Serial COM port. We use the RS232 Java COMM API (javax.comm.properties, comm.jar, win32com.dll) to achieve the same. Currently the code works fine on Windows XP 32-bit, Vista 32-bit and Windows 7. However we are having a problem trying to communicate on Vista 64-bit. I read from the Java forums that there is no 64-bit support for the Java COMM API I was wondering if anyone was facing a similar situation and were able to resolve the same in some way?

    Read the article

  • Port blackberry to android app

    - by donald
    Hey, I am porting a blackberry application to android phone. The app is talking to web service using soap api. Is it possible to use ksoap2 available for android and use the same soap stub? if so, how? or I have to rewrite from scratch? I have never used soap/rest api's before, so m confused.

    Read the article

  • xdebug in netbeans won't bind to port 9000

    - by allenskd
    I've been trying to configure xdebug to work along with netbeans, my current configuration is [xdebug] zend_extension="C:\binaries\php\ext\php_xdebug-2.1.0RC1-5.3-vc6.dll" xdebug.remote_enable=on xdebug.remote_handler=dbgp xdebug.remote_host=127.0.0.1 (also tried localhost) xdebug.remote_port=9000 xdebug.idekey="netbeans-xdebug" I tried the test provided by a netbeans blog explaining how to test if the configuration works when binding it just outputs "unable to bind" Any suggestions?

    Read the article

  • DataReceived Event handler not receiving messages

    - by karthik
    I'm using the below code to receive the messages using serial port event handler. But it dosent receives any.I am not getting errors. The code breaks in "string msg = comport.Readline()" Am i doing something wrong ? public partial class SerialPortScanner : Form { private SerialPort comPort = new SerialPort(); public SerialPortScanner() { InitializeComponent(); comPort.Open(); comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); } void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadLine(); MessageBox.Show(msg); } } }

    Read the article

  • weird characters displayed during serial communication OSX

    - by nemo
    I have tried communicating via serial (OSX w/ prolific drivers - USB RS232 adapter - Tx,Rx and GND pins on device serial ttl port) to a device and done so successfully using screen /dev/tty.usbserial 115200 8N1 I get to log in and use it as if I was SSH or TelNetted in... However whenever I try to go into system recovery mode (holding CTRL+1) while the device is powering on, it starts displaying weird characters and until I close the screen session it will continue showing weird characters: Of course when we tried doing the same thing on my boss' macbook running windows and PuTTY and everything worked fine, even in system recovery mode; characters were displayed properly. What gives? Id like to learn the intuition to use because up till now I concluded that since I can bot into the system and see characters normally everything about the connection should be fine and its must have been the recovery partition that was broken. This was wrong of course... Niko

    Read the article

  • Issue with SPI (Serial Port Comm), stuck on ioctl()

    - by stef
    I'm trying to access a SPI sensor using the SPIDEV driver but my code gets stuck on IOCTL. I'm running embedded Linux on the SAM9X5EK (mounting AT91SAM9G25). The device is connected to SPI0. I enabled CONFIG_SPI_SPIDEV and CONFIG_SPI_ATMEL in menuconfig and added the proper code to the BSP file: static struct spi_board_info spidev_board_info[] { { .modalias = "spidev", .max_speed_hz = 1000000, .bus_num = 0, .chips_select = 0, .mode = SPI_MODE_3, }, ... }; spi_register_board_info(spidev_board_info, ARRAY_SIZE(spidev_board_info)); 1MHz is the maximum accepted by the sensor, I tried 500kHz but I get an error during Linux boot (too slow apparently). .bus_num and .chips_select should correct (I also tried all other combinations). SPI_MODE_3 I checked the datasheet for it. I get no error while booting and devices appear correctly as /dev/spidevX.X. I manage to open the file and obtain a valid file descriptor. I'm now trying to access the device with the following code (inspired by examples I found online). #define MY_SPIDEV_DELAY_USECS 100 // #define MY_SPIDEV_SPEED_HZ 1000000 #define MY_SPIDEV_BITS_PER_WORD 8 int spidevReadRegister(int fd, unsigned int num_out_bytes, unsigned char *out_buffer, unsigned int num_in_bytes, unsigned char *in_buffer) { struct spi_ioc_transfer mesg[2] = { {0}, }; uint8_t num_tr = 0; int ret; // Write data mesg[0].tx_buf = (unsigned long)out_buffer; mesg[0].rx_buf = (unsigned long)NULL; mesg[0].len = num_out_bytes; // mesg[0].delay_usecs = MY_SPIDEV_DELAY_USECS, // mesg[0].speed_hz = MY_SPIDEV_SPEED_HZ; mesg[0].bits_per_word = MY_SPIDEV_BITS_PER_WORD; mesg[0].cs_change = 0; num_tr++; // Read data mesg[1].tx_buf = (unsigned long)NULL; mesg[1].rx_buf = (unsigned long)in_buffer; mesg[1].len = num_in_bytes; // mesg[1].delay_usecs = MY_SPIDEV_DELAY_USECS, // mesg[1].speed_hz = MY_SPIDEV_SPEED_HZ; mesg[1].bits_per_word = MY_SPIDEV_BITS_PER_WORD; mesg[1].cs_change = 1; num_tr++; // Do the actual transmission if(num_tr > 0) { ret = ioctl(fd, SPI_IOC_MESSAGE(num_tr), mesg); if(ret == -1) { printf("Error: %d\n", errno); return -1; } } return 0; } Then I'm using this function: #define OPTICAL_SENSOR_ADDR "/dev/spidev0.0" ... int fd; fd = open(OPTICAL_SENSOR_ADDR, O_RDWR); if (fd<=0) { printf("Device not found\n"); exit(1); } uint8_t buffer1[1] = {0x3a}; uint8_t buffer2[1] = {0}; spidevReadRegister(fd, 1, buffer1, 1, buffer2); When I run it, the code get stuck on IOCTL! I did this way because, in order to read a register on the sensor, I need to send a byte with its address in it and then get the answer back without changing CS (however, when I tried using write() and read() functions, while learning, I got the same result, stuck on them). I'm aware that specifying .speed_hz causes a ENOPROTOOPT error on Atmel (I checked spidev.c) so I commented that part. Why does it get stuck? I though it can be as the device is created but it actually doesn't "feel" any hardware. As I wasn't sure if hardware SPI0 corresponded to bus_num 0 or 1, I tried both, but still no success (btw, which one is it?). UPDATE: I managed to have the SPI working! Half of it.. MOSI is transmitting the right data, but CLK doesn't start... any idea?

    Read the article

  • DataReceived Event handler not receiving messages using c#

    - by karthik
    I'm using the below code to receive the messages using serial port event handler. But it dosent receives any.I am not getting errors. The code breaks in "string msg = comport.Readline()" Am i doing something wrong ? public partial class SerialPortScanner : Form { private SerialPort comPort = new SerialPort(); public SerialPortScanner() { InitializeComponent(); comPort.Open(); comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); } void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadLine(); MessageBox.Show(msg); } } }

    Read the article

  • Recommendation for serial communications in Access 2007

    - by bglenn
    I need to communicate with a bar code scanner connected over a serial port in Microsoft Access. In older versions of Access I was able to use a wrapper around MSCOMM32.ocx that no longer seems to work. I can't use wedge communication because I need to use ACK/NACK which is only supported through the RS232 interface and I need to send messages to the scanner, which is also only supported through the RS232 interface. Are there any controls in widespread use that support serial communication in Access 2007? EDIT: In case anyone comes across this, the newest version of MSCOMM32.ocx (I believe dated 3/09) still works fine as of this writing. It is older versions of MSCOMM32.ocx that do not work.

    Read the article