Search Results

Search found 19131 results on 766 pages for 'power options'.

Page 72/766 | < Previous Page | 68 69 70 71 72 73 74 75 76 77 78 79  | Next Page >

  • Is it possible to power off a PCIe video card/slot? (eg. hot-plug)

    - by CR.
    I'm looking at building a system that supports VT-d so I can pass through a high powered loud video card to a Xen/KVM/whatever VM (host will be Linux based). However, when I'm not using the VM I want to turn the video card off so its fan does not run. The card will not be used when the VM isn't running. Anyone know if this is possible? The PCI-Express hot-plug specification allows cutting power to specific slots but I have never heard of anyone doing it with a video card and my searches for information have turned up nothing.

    Read the article

  • In terms of load handling, which is better: one server or two of equivalent power?

    - by seldary
    My goal is to figure out if i'm better off with one strong server, or multiple weaker servers with a load balancer. Does the fact of splitting the load between servers have an effect on the total load my website could take? It's hard to single that out, because there are of course a lot of parameters that affect the results, so some assumptions: Putting failover considerations aside - I know it matters, but for the sake of the question's simplicity, lets assume nothing fails. The servers in the multiple servers option have an accumulated "power" equivalent to the one server option (about the same amount of cores and RAM space). If that is too theoretical, here is a concrete question that could help: Suppose I have several instances of exactly the same server - lets call it S. Suppose that server S can serve a load of up to X calls per time unit. Will two S servers with a load balancer serve 2X calls per time unit? significantly more? significantly less?

    Read the article

  • Sound issues after trying everything

    - by Lerp
    I cannot get my sound working properly, no matter what I do, there's always some problem. It's very annoying as it's the only thing preventing me from making Ubuntu my main OS. At the moment my sound always plays through both my speakers and my headphones regardless except the sound through the headphones is crackly. It is also a bit quiet even though everything is maxed. I've managed to improve the situation to a point where the sound out of my speakers is perfect but I have none at all from my headphones. I do have two connectors listed in the sound settings but regardless of which one is selected it always plays through the speakers. I think this might have something to do with the fact that my speakers are plugging into the front of my computer, typically the headphone jack, and my headphones are plugging into the back but when I try disconnecting the speakers from the front there is still no sound from the headphones. I fixed the speaker sound by going through the sound settings and making sure they were all set to 100% then rebooting. Things I have tried: Maxing everything and unmuting everything in alsamixer Uninstalling pulseaudio Making gstreamer use only alsa via gstreamer-properties. This worked with the sound test button including independent sound between headphones and speakers but when I reset the computer it no longer worked. So I tried setting it manually in gconf-editor which didn't work either. Reinstalling alsa and pulseaudio Setting the model in /etc/modprobe.d/alsa-base.conf to 6stack and 6stack-dig neither worked. Upgrading to 12.10 Here's some command output to help you diagnose my problem. aplay -l **** List of PLAYBACK Hardware Devices **** card 0: Intel [HDA Intel], device 0: AD198x Analog [AD198x Analog] Subdevices: 0/1 Subdevice #0: subdevice #0 card 0: Intel [HDA Intel], device 1: AD198x Digital [AD198x Digital] Subdevices: 1/1 Subdevice #0: subdevice #0 card 0: Intel [HDA Intel], device 2: AD198x Headphone [AD198x Headphone] Subdevices: 1/1 Subdevice #0: subdevice #0 sudo lshw -C sound *-multimedia description: Audio device product: 82801JI (ICH10 Family) HD Audio Controller vendor: Intel Corporation physical id: 1b bus info: pci@0000:00:1b.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:70 memory:f7ff8000-f7ffbfff cat /proc/asound/card*/codec* | grep "Codec" Codec: Analog Devices AD1989B cat /etc/modprobe.d/alsa-base.conf # autoloader aliases install sound-slot-0 /sbin/modprobe snd-card-0 install sound-slot-1 /sbin/modprobe snd-card-1 install sound-slot-2 /sbin/modprobe snd-card-2 install sound-slot-3 /sbin/modprobe snd-card-3 install sound-slot-4 /sbin/modprobe snd-card-4 install sound-slot-5 /sbin/modprobe snd-card-5 install sound-slot-6 /sbin/modprobe snd-card-6 install sound-slot-7 /sbin/modprobe snd-card-7 # Cause optional modules to be loaded above generic modules install snd /sbin/modprobe --ignore-install snd $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-ioctl32 ; /sbin/modprobe --quiet --use-blacklist snd-seq ; } # # Workaround at bug #499695 (reverted in Ubuntu see LP #319505) install snd-pcm /sbin/modprobe --ignore-install snd-pcm $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-pcm-oss ; : ; } install snd-mixer /sbin/modprobe --ignore-install snd-mixer $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-mixer-oss ; : ; } install snd-seq /sbin/modprobe --ignore-install snd-seq $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-seq-midi ; /sbin/modprobe --quiet --use-blacklist snd-seq-oss ; : ; } # install snd-rawmidi /sbin/modprobe --ignore-install snd-rawmidi $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-seq-midi ; : ; } # Cause optional modules to be loaded above sound card driver modules install snd-emu10k1 /sbin/modprobe --ignore-install snd-emu10k1 $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-emu10k1-synth ; } install snd-via82xx /sbin/modprobe --ignore-install snd-via82xx $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist snd-seq ; } # Load saa7134-alsa instead of saa7134 (which gets dragged in by it anyway) install saa7134 /sbin/modprobe --ignore-install saa7134 $CMDLINE_OPTS && { /sbin/modprobe --quiet --use-blacklist saa7134-alsa ; : ; } # Prevent abnormal drivers from grabbing index 0 options bt87x index=-2 options cx88_alsa index=-2 options saa7134-alsa index=-2 options snd-atiixp-modem index=-2 options snd-intel8x0m index=-2 options snd-via82xx-modem index=-2 options snd-usb-audio index=-2 options snd-usb-caiaq index=-2 options snd-usb-ua101 index=-2 options snd-usb-us122l index=-2 options snd-usb-usx2y index=-2 # Ubuntu #62691, enable MPU for snd-cmipci options snd-cmipci mpu_port=0x330 fm_port=0x388 # Keep snd-pcsp from being loaded as first soundcard options snd-pcsp index=-2 # Keep snd-usb-audio from beeing loaded as first soundcard options snd-usb-audio index=-2 options snd-hda-intel model=6stack

    Read the article

  • Please help me give this principle a name

    - by Brent Arias
    As a designer, I like providing interfaces that cater to a power/simplicity balance. For example, I think the LINQ designers followed that principle because they offered both dot-notation and query-notation. The first is more powerful, but the second is easier to read and follow. If you disagree with my assessment of LINQ, please try to see my point anyway; LINQ was just an example, my post is not about LINQ. I call this principle "dial-able power". But I'd like to know what other people call it. Certainly some will say "KISS" is the common term. But I see KISS as a superset, or a "consumerism" practice. Using LINQ as my example again, in my view, a team of programmers who always try to use query notation over dot-notation are practicing KISS. Thus the LINQ designers practiced "dial-able power", whereas the LINQ consumers practice KISS. The two make beautiful music together. I'll give another example. Imagine a C# logging tool that has two signatures allowing two uses: void Write(string message); void Write(Func<string> messageCallback); The purpose of the two signatures is to fulfill these needs: //Every-day "simple" usage, nothing special. myLogger.Write("Something Happened" + error.ToString() ); //This is performance critical, do not call ToString() if logging is //disabled. myLogger.Write( () => { "Something Happened" + error.ToString() }); Having these overloads represents "dial-able power," because the consumer has the choice of a simple interface or a powerful interface. A KISS-loving consumer will use the simpler signature most of the time, and will allow the "busy" looking signature when the power is needed. This also helps self-documentation, because usage of the powerful signature tells the reader that the code is performance critical. If the logger had only the powerful signature, then there would be no "dial-able power." So this comes full-circle. I'm happy to keep my own "dial-able power" coinage if none yet exists, but I can't help think I'm missing an obvious designation for this practice. p.s. Another example that is related, but is not the same as "dial-able power", is Scott Meyer's principle "make interfaces easy to use correctly, and hard to use incorrectly."

    Read the article

  • Issues with configuration of Apache and mod_auth_sspi

    - by TekiusFanatikus
    I've been able to get this working using XAMP with Apache 2.0.55 and XAMP Apache 2.2.14 without any problems. However, when I attempt to configure our intranet server (Apache 2.0.59), I don't get the same results. The results are that the following variables contain the information desired: $_SERVER["REMOTE_USER"] AND $_SERVER["PHP_AUTH_USER"]. In this case, they are blank. I'm expecting "domain/user_name". Conf file stuff: <Directory "/xxx/xampp/htdocs/"> # # Possible values for the Options directive are "None", "All", # or any combination of: # Indexes Includes FollowSymLinks SymLinksifOwnerMatch ExecCGI MultiViews # # Note that "MultiViews" must be named *explicitly* --- "Options All" # doesn't give it to you. # # The Options directive is both complicated and important. Please see # http://httpd.apache.org/docs/2.2/mod/core.html#options # for more information. # #Options Indexes FollowSymLinks Includes ExecCGI Options Indexes FollowSymLinks # # AllowOverride controls what directives may be placed in .htaccess files. # It can be "All", "None", or any combination of the keywords: # Options FileInfo AuthConfig Limit # #AllowOverride All AllowOverride None # # Controls who can get stuff from this server. # #Order allow,deny #Allow from all Order allow,deny Allow from all #NT Domain Login AuthName "Intranet" AuthType SSPI SSPIAuth On SSPIAuthoritative On SSPIDomain "xxxx" SSPIOfferBasic Off SSPIPerRequestAuth On SSPIOmitDomain Off # keep domain name in userid string SSPIUsernameCase lower Require valid-user </Directory> I would like to note that I've modified the paths to reflect the intranet environment. I'm using the following module: http://sourceforge.net/projects/mod-auth-sspi/ Once the module is installed and the conf file is modified, the intranet environment's server scope isn't populated with the expected variables. Edit #1 <Directory "/path_here"> # # Possible values for the Options directive are "None", "All", # or any combination of: # Indexes Includes FollowSymLinks SymLinksifOwnerMatch ExecCGI MultiViews # # Note that "MultiViews" must be named *explicitly* --- "Options All" # doesn't give it to you. # # The Options directive is both complicated and important. Please see # http://httpd.apache.org/docs/2.2/mod/core.html#options # for more information. # #Options Indexes FollowSymLinks Includes ExecCGI Options Indexes FollowSymLinks # # AllowOverride controls what directives may be placed in .htaccess files. # It can be "All", "None", or any combination of the keywords: # Options FileInfo AuthConfig Limit # #AllowOverride All AllowOverride None # # Controls who can get stuff from this server. # #Order allow,deny #Allow from all Order allow,deny Allow from all #NT Domain Login AuthName "Intranet" AuthType SSPI SSPIAuth On SSPIAuthoritative On SSPIDomain "domain_here" SSPIOfferBasic On SSPIPerRequestAuth On SSPIOmitDomain Off # keep domain name in userid string SSPIUsernameCase lower Require valid-user </Directory>

    Read the article

  • Knowledge Pathways Designer - Recommended Settings

    - by ted.henson
    The General page of the Options dialog box contains the application preferences for Knowledge Pathways Designer. It is recommended that you leave certain settings as they are, unless you have a specific reason for changing them. The following are a few of the settings on the General page with an explanation of the recommended setting. They are in the order they appear on the page: Allow version 2.0 style links: This option should remain disabled unless you were using content that was created using version 2.0 of Knowledge Pathways and you want the same linking functionality that existed in that version 2.0. This feature enables you to reuse parts of titles that contain no AUs. However, keep in mind that this type of link is not a true link, but a cross between a copy and a link. To create a 2.0 style link, you drag and drop sections between titles. You can only create 2.0 style links to sections that belong to the Title AU. When creating a version 2.0 style link, your mouse pointer will change to indicate a 2.0 link is being created. Confirm deletion of outline items and Confirm deletion of titles: It is recommended that these options remain enabled to avoid deleting something by accident. Display tracking data loss warning when opening a published title: It recommended that this option be enabled so you will receive the warning message when you open the development copy of a title, reminding you of the implications of your changes. ulCopy files when converting a Section to an Assignable Unit: This option should remain enabled unless you have a specific reason for not copying the files. If this is disabled, you will (in effect) lose your content files upon converting because they will not be copied to the new AU directory on the content root. In this case, you would need to use Windows Explorer to copy your files manually. Working with Spelling Options All of the spelling options are enabled by default. Your design team can review these options to determine if you want to make changes, depending upon your specific needs. Understanding Dictionary Options You should leave the dictionary options as they are, unless you have a specific reason for changing them. While you can delete the user (customizable) dictionary, doing so is not recommended. Setting Check In/Check Out Options The ability to check in and check out titles and AUs will impact the efficiency of your design team. Decide what your check in and check out processes are before you start developing titles. The Check In/Check Out page of the Options dialog box contains two options that affect what happens when you open a title using the Open Title dialog box. Both of these options are enabled by default and are described below: Check Out for editing enabled: This option ensures that the Check Out for editing option will be selected when you open the development copy of a title from the Open Title dialog box. If this option is disabled, you must select the Check Out for editing option every time you want to check out a title for editing. Attempt to Check Out for entire branch: When this option is enabled, Designer checks out the selected title and all AUs and sections that are part of that title, provided they are available for check out. If this option is disabled, you will only check out the Title AU and anything that belongs to that Title AU (e.g., sections, questions, etc.), but not other AUs. The Check In/Check Out page of the Options dialog box also contains options that control what happens when you close a title. You can choose one option in the Check In when Closing a Title area. The option selected is a matter of preference and you should determine which option is most appropriate for your design team.

    Read the article

  • Is post-sudden-power-loss filesystem corruption on an SSD drive's ext3 partition "expected behavior"?

    - by Jeremy Friesner
    My company makes an embedded Debian Linux device that boots from an ext3 partition on an internal SSD drive. Because the device is an embedded "black box", it is usually shut down the rude way, by simply cutting power to the device via an external switch. This is normally okay, as ext3's journalling keeps things in order, so other than the occasional loss of part of a log file, things keep chugging along fine. However, we've recently seen a number of units where after a number of hard-power-cycles the ext3 partition starts to develop structural issues -- in particular, we run e2fsck on the ext3 partition and it finds a number of issues like those shown in the output listing at the bottom of this Question. Running e2fsck until it stops reporting errors (or reformatting the partition) clears the issues. My question is... what are the implications of seeing problems like this on an ext3/SSD system that has been subjected to lots of sudden/unexpected shutdowns? My feeling is that this might be a sign of a software or hardware problem in our system, since my understanding is that (barring a bug or hardware problem) ext3's journalling feature is supposed to prevent these sorts of filesystem-integrity errors. (Note: I understand that user-data is not journalled and so munged/missing/truncated user-files can happen; I'm specifically talking here about filesystem-metadata errors like those shown below) My co-worker, on the other hand, says that this is known/expected behavior because SSD controllers sometimes re-order write commands and that can cause the ext3 journal to get confused. In particular, he believes that even given normally functioning hardware and bug-free software, the ext3 journal only makes filesystem corruption less likely, not impossible, so we should not be surprised to see problems like this from time to time. Which of us is right? Embedded-PC-failsafe:~# ls Embedded-PC-failsafe:~# umount /mnt/unionfs Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Invalid inode number for '.' in directory inode 46948. Fix<y>? yes Directory inode 46948, block 0, offset 12: directory corrupted Salvage<y>? yes Entry 'status_2012-11-26_14h13m41.csv' in /var/log/status_logs (46956) has deleted/unused inode 47075. Clear<y>? yes Entry 'status_2012-11-26_10h42m58.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47076. Clear<y>? yes Entry 'status_2012-11-26_11h29m41.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47080. Clear<y>? yes Entry 'status_2012-11-26_11h42m13.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47081. Clear<y>? yes Entry 'status_2012-11-26_12h07m17.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47083. Clear<y>? yes Entry 'status_2012-11-26_12h14m53.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47085. Clear<y>? yes Entry 'status_2012-11-26_15h06m49.csv' in /var/log/status_logs (46956) has deleted/unused inode 47088. Clear<y>? yes Entry 'status_2012-11-20_14h50m09.csv' in /var/log/status_logs (46956) has deleted/unused inode 47073. Clear<y>? yes Entry 'status_2012-11-20_14h55m32.csv' in /var/log/status_logs (46956) has deleted/unused inode 47074. Clear<y>? yes Entry 'status_2012-11-26_11h04m36.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47078. Clear<y>? yes Entry 'status_2012-11-26_11h54m45.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47082. Clear<y>? yes Entry 'status_2012-11-26_12h12m20.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47084. Clear<y>? yes Entry 'status_2012-11-26_12h33m52.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47086. Clear<y>? yes Entry 'status_2012-11-26_10h51m59.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47077. Clear<y>? yes Entry 'status_2012-11-26_11h17m09.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47079. Clear<y>? yes Entry 'status_2012-11-26_12h54m11.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47087. Clear<y>? yes Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Couldn't fix parent of inode 46948: Couldn't find parent directory entry Pass 4: Checking reference counts Unattached inode 46945 Connect to /lost+found<y>? yes Inode 46945 ref count is 2, should be 1. Fix<y>? yes Inode 46953 ref count is 5, should be 4. Fix<y>? yes Pass 5: Checking group summary information Block bitmap differences: -(208264--208266) -(210062--210068) -(211343--211491) -(213241--213250) -(213344--213393) -213397 -(213457--213463) -(213516--213521) -(213628--213655) -(213683--213688) -(213709--213728) -(215265--215300) -(215346--215365) -(221541--221551) -(221696--221704) -227517 Fix<y>? yes Free blocks count wrong for group #6 (17247, counted=17611). Fix<y>? yes Free blocks count wrong (161691, counted=162055). Fix<y>? yes Inode bitmap differences: +(47089--47090) +47093 +47095 +(47097--47099) +(47101--47104) -(47219--47220) -47222 -47224 -47228 -47231 -(47347--47348) -47350 -47352 -47356 -47359 -(47457--47488) -47985 -47996 -(47999--48000) -48017 -(48027--48028) -(48030--48032) -48049 -(48059--48060) -(48062--48064) -48081 -(48091--48092) -(48094--48096) Fix<y>? yes Free inodes count wrong for group #6 (7608, counted=7624). Fix<y>? yes Free inodes count wrong (61919, counted=61935). Fix<y>? yes embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: ********** WARNING: Filesystem still has errors ********** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Directory entry for '.' in ... (46948) is big. Split<y>? yes Missing '..' in directory inode 46948. Fix<y>? yes Setting filetype for entry '..' in ... (46948) to 2. Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Pass 4: Checking reference counts Inode 2 ref count is 12, should be 13. Fix<y>? yes Pass 5: Checking group summary information embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite: clean, 657/62592 files, 87882/249937 blocks

    Read the article

  • Apache Options -Indexes give me 404 instead of 403, why?

    - by netmano
    I have an Apache/2.2.21 (Debian) webserver, which I disabled directory listing with Options -Indexes but now I got 404 error for a directory, but I think I should get a 403. I have no idea why I get 404, rather than 403. What should I check? I have disabled autoindex module, after it I got a 404 for every URL that request a directory listing (eg: www.somesite.com/dir ). How can I get a 403 for this. (The dir does exist) As a try I also put Options -Index in the end of main config file (apache2.conf).

    Read the article

  • How to easily use Windows 7 search advanced options?

    - by Scott Evernden
    Is there an alternative to trying to remember all the advanced search options? Like an actual GUI as we had for windows XP? As powerful as Windows Search apparently is, I cannot possibly remember all the options available. How is a mere mortal like my Dad supposed to understand and retain all this? I get the shakes every time i need to find something on Win 7. Anyone have some relief? Part 2: Why does it RE-run a search if i add a column and try to sort on that?

    Read the article

  • Can I disable Pam Loginuid? Can I find out options used to configure kernel?

    - by dunxd
    I am getting a lot of the following types of error in my secure log on a CentOS 5.4 server: crond[10445]: pam_loginuid(crond:session): set_loginuid failed opening loginuid sshd[10473]: pam_loginuid(sshd:session): set_loginuid failed opening loginuid I've seen discussion of this being caused when using a non-standard kernel without the correct CONFIG_AUDIT and CONFIG_AUDITSYSCALL options set. Where this is the case, it is advised to comment out some lines in the pam.d config files. I am running a Virtual Private Server where I need to use the kernel provided by the supplier. Is there a way to find out what options they used to configure the kernel? I want to verify if the above is the cause. If this turns out not to be the cause, what are the risk of disabling pam_loginuid for crond and sshd?

    Read the article

  • Using Internet Explorer 8 and 9 beta under internet options -advanced java does not show to check the box

    - by Michael Bishop
    I am using internet 8 and under internet options advanced there is not box to check to enable java. I was told to reset which did nto work. I have tried to uninstall java 6-21 32 bit but I get windows installer error 1723. I brought up the java console and made sure it was pointing to the right target. But I guess the main thing is I have no enable java under internet options, advanced. It was under security to enable java scripting. Any answers?

    Read the article

  • Where to set java heap options (e.g. -Xmx) for Tomcat 6 under Ubuntu 9.04?

    - by Chris
    I'm running Tomcat using the tomcat6 package from Ubuntu 9.04, which makes a daemon out of Tomcat using jsvc. I'd like to know the proper way to set Java heap options like -Xmx for Tomcat. I'd like to put the configuration wherever is most stylistically correct, and wherever is least likely to be overwritten by Ubuntu package updates. The options I see right now: Hard-code them somewhere in /etc/init.d/tomcat6. Hard-code them somewhere in /usr/share/tomcat6/bin/catalina.sh. Create a line in /usr/share/tomcat6/bin/startup.sh to set CATALINA_OPTS to have the desired flags, and then export CATALINA_OPTS as an environment variable. (This looks like it will get picked up by catalina.sh.) The last option sounds like the best one, and it's advocated (without explanation of why) at http://serverfault.com/questions/121038/increasing-javas-heapspace-in-tomcat-startup-script. But I wanted to get a second opinion. Anyone want to confirm that there isn't a better way?

    Read the article

  • How to assess a job offer with stock options? [closed]

    - by seas
    Cannot help expressing my curiosity about this issue. First of all, Russia, a country, I live in, as far as I understand, is a virgin land on this matter. Motivation is purely developed here and options are not existed at all. So, I am absolutely not aware about this. I roughly understand the mechanism of options. And, as far as I understand, the major white spot in the whole that story, how much will a singe share cost. How much will I get from all those N x 1000 options? I see two ways one can get money from the business: 1. Business goes IPO !!! 2. Business is sold as a whole to another owner. Next way is rather questionable about getting money: 3. Business goes without IPO "forever" (a generation would rather die before it IPO). I am also interested some explanations about situation ?3. Situation ?1 is clear - market decides everything, you either wait for stock price you satisfied or sell everything now. But topic is rather about ?2 - business is sold to another business. I am considering the following model: I am well payed specialist with company X. Somebody, with a company Y makes me an offer. Y is a startup. They cannot offer me much money and cannot overbid my salary, but they grow fast and hope to be bought soon. Instead of money, they offer me N x 1000 options. My problem is "how to assess this offer against my current, stable and well-payed job"? Are there any average cost of virtual share during selling one company to another? Are there any average stock price companies prefer to go to IPO? Are there any barriers against spreading the value of sock before selling the company or IPO (hiring too much people with options package too fast will decrease each package value, I mean)? Are there any good articles with explanations? Is all that somehow written in the law?

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • WHM Checking server status so frequently?

    - by Webnet
    Why do I have so many whm-server-status elements on this Apache status screen for WHM. 0-1 28256 0/4/808 _ 0.20 5 26 0.0 0.19 6.62 72.95.166.85 diablo-source.gamer-source.com GET /lib/ajax/keep-alive.php?_dc=1276829050557 HTTP/1.1 1-1 28259 0/5/934 _ 0.00 4 188 0.0 0.06 6.67 127.0.0.1 server.gospire.com GET /whm-server-status/ HTTP/1.0 2-1 - 0/0/940 . 0.18 55 0 0.0 0.00 6.61 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 3-1 - 0/0/914 . 0.49 28 0 0.0 0.00 8.46 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 4-1 - 0/0/837 . 0.00 62 0 0.0 0.00 7.49 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 5-1 27580 0/15/849 _ 6.36 7 188 0.0 0.69 6.89 127.0.0.1 server.gospire.com GET /whm-server-status/ HTTP/1.0 6-1 - 0/0/829 . 0.00 58 0 0.0 0.00 4.20 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 7-1 - 0/0/878 . 0.03 47 0 0.0 0.00 4.62 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 8-1 26737 0/19/759 W 7.55 93 0 0.0 0.93 8.24 76.76.103.50 gamer-source.com GET /development-blog/?p=101&cpage=108 HTTP/1.0 9-1 - 0/0/847 . 0.36 61 0 0.0 0.00 7.90 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 10-1 28233 0/8/705 _ 0.17 6 201 0.0 0.06 6.18 127.0.0.1 server.gospire.com GET /whm-server-status/ HTTP/1.0 11-1 - 0/0/754 . 0.00 48 0 0.0 0.00 6.50 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 12-1 28235 0/6/670 W 0.11 25 0 0.0 0.04 3.15 76.76.103.50 gamer-source.com GET /development-blog/?p=104&cpage=1 HTTP/1.0 13-1 - 0/0/611 . 0.00 60 0 0.0 0.00 4.76 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 14-1 - 0/0/713 . 0.00 59 0 0.0 0.00 5.70 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 15-1 - 0/0/696 . 0.00 57 0 0.0 0.00 4.85 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 16-1 - 0/0/695 . 0.50 73 0 0.0 0.00 4.43 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 17-1 - 0/0/547 . 0.17 56 0 0.0 0.00 4.89 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 18-1 - 0/0/472 . 0.00 80 0 0.0 0.00 2.05 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 19-1 27588 0/7/423 _ 6.59 1 184 0.0 0.69 2.79 127.0.0.1 server.gospire.com GET /whm-server-status/ HTTP/1.0 20-1 27589 0/6/420 _ 6.54 3 184 0.0 0.71 3.62 127.0.0.1 server.gospire.com GET /whm-server-status/ HTTP/1.0 21-1 28242 0/10/374 _ 0.44 6 819 0.0 0.05 1.81 67.195.114.23 gamer-source.com GET /development-blog/?p=120 HTTP/1.0 22-1 - 0/0/359 . 0.00 79 0 0.0 0.00 3.45 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 23-1 - 0/0/326 . 0.16 163 0 0.0 0.00 2.64 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 24-1 - 0/0/430 . 0.40 74 0 0.0 0.00 3.30 127.0.0.1 server.gospire.com OPTIONS * HTTP/1.0 25-1 27624 0/23/276 W 0.78 0 0 0.0 0.16 1.08 127.0.0.1 server.gospire.com GET /whm-server-status/ HTTP/1.0

    Read the article

  • Can't Get Mac Mini to turn on - no screen, no beep, only the fan, power light, and optical drive noi

    - by pibyers
    I have an Intel-based Mac mini mid-2007 (Model A1176). This is the computer my kids use so I don't use it regularly. The computer had been working fine until one day my kids told me that it no longer works. The computer will not boot up. When I turn it on the fan turns, the white power light in the front turns on, and there is a sound that appears to be from the optical drive (rather than hard drive). I don't get anything to the monitor, nor do I get any dings or other start up sounds from the computer. Here is what I've tried thus far to no avail: 1) Swapped out the monitors early on since I figured that was my weak link - no change 2) Reset the PMU - no change 3) Tried to boot up from the System Disk - The mini loaded the dvd into the drive, but nothing else (I can't eject the disk so I can put it back) 3) Start up the computer in target mode connected to another mac - I tried this too, but I never received a chime or the disk show up on the other mac. I'm about out of ideas apart from scraping the computer. Does anyone have any ideas that I can try? Again, nothing has been done to the computer in at least 6 months when I upgraded the RAM. I'm also still on Leopard. Thanks.

    Read the article

  • What can I do to prevent system power downs?

    - by Joe King
    Yesterday I was given my brother's old laptop - core i7, 2.67GHz, 8GB RAM, 128GB SSD, Win7 64 bit. It's a Sony Vaio Z11. Approx 18 months old. When running something computationally intensive, the fan starts up and after about 30 secs it just powers itself down with no warning. I guess it is overheating. There is nothing in the event logs to suggest what is causing it - the only thing I see is "the last system shutdown was unexpected" or something similar. This is a problem for me because I use a lot of number crunching apps, which pretty much makes it useless to me. I would like to know if there is anything I can do, other than the obvious things I've done already - open up and clean out dust, re-install the OS. According to my brother, this problem started about 6 months ago when it was already outside warranty. If it's just used for simple things - web browsing, word processing etc, the problem does not occur. Any ideas for what I can do to fix this ? Update: I found that the laptop has 2 hardware settings for graphics: Speed and Stamina - the Speed setting seems to use an nvidia GEforce GT 330M, while the Stamina setting uses an Intel chipset. With the setting on Speed, I can hear the fan the whole time, and the system powers down after a short while (5-10 mins) even just doing basic tasks (browsing this site for example), but doesn't shut down if I just leave it switched on. In this mode it also sometimes just freezes the screen and I have to power off myself. However on Stamina setting it only powers down when doing number crunching and never freezes the screen.

    Read the article

  • How to make the value of one select box drive the options of a second select box

    - by Ben McCormack
    I want to make an HTML form with 2 select boxes. The selected option in the first select box should drive the options in the second select box. I would like to solve this dynamically on the client (using javascript or jQuery) rather than having to submit data to the server. For example, let's say I have the following Menu Categories and Menu Items: Sandwiches Turkey Ham Bacon Sides Mac 'n Cheese Mashed Potatoes Drinks Coca Cola Sprite Sweetwater 420 I would have two select boxes, named Menu Category and Items, respectively. When the user selects Sandwiches in the Menu Category box, the options in the Items box will only show Sandwich options. I'm stuck as how I might approach this. Once I filter out the 2nd list one time, how do I "find" the list options once I change my menu category in the 1st list? Also, if I'm thinking in SQL, I would have a key in the 1st box that would be used to link to the data in the 2nd box. However, I can't see where I have room for a "key" element in the 2nd box. How could this problem be solved with a combination of jQuery or plain javascript?

    Read the article

  • JQuery plugin: catch events for clicking/tabbing into and out of an input box

    - by poswald
    I'm creating a Javascript JQuery Timepicker control plugin (which I hope to open source soon) and I would like some advice on how to best register the events in the cleanest way. The control will attach to an <input> box and provide a graphical way to enter times of day ( 14:25, 2:45 AM, etc...). It does this by adding a <div> after the input box. What I want is to bind an openControl() function that fires when the input is clicked or tabbed to, and a closeControl() function that fires when the input box is tabbed away from or deselected but not if the control itself is clicked. That is, I don't want to close the control if you're clicking inside of the control's <input> or the <div>. Here's what I have been doing to try to get there: /* Close the control attached to the passed inputNode */ function closeContainer(inputNode, options) { $input = $(inputNode); if ( $input.next().is(':visible')) { $input.next().hide(options.hideAnim, options.hideOptions, options.hideDuration, options.onHide ); } } /* Open the control */ function openContainer(node, options) { $input = $(node); $input.next().show(options.showAnim, options.showOptions, options.showDuration, options.onShow ); // bind a click handler for closing the contol $("body").bind('click', function (e) { $('.time-control').each( function () { $input = $(this).prev(); // only close if click is outside of the control or the input box if (jQuery.contains(this, e.target) || ($input.get(0) === e.target) ) { closeContainer($input, options); setTime($input, $input.next(), options); } else { closeContainer($input, options); } }); }); } I want to add support for tabbing in/out but I feel like this approach is wrong. Focus/Blur wasn't working well because the blur event fires if you click on the control. Should I be using those events but filtering out if they are inside the control's div? Anyone have a better way of doing this? Thanks!

    Read the article

  • Is there a way to force the monitor to power off in Windows 8?

    - by Rune Jacobsen
    I have googled this a bit and looked at powrprof.dll and PsShutdown but I haven't found a way to do exactly what I want to do. You know that power save option that lets Windows turn off your monitor(s) if you haven't touched the system for x amount of time? Well, I have a PC that needs to be on most of the day (and night), and I have to watch it much of the time, so I can't have a short timeout for automatically turning off the monitor. However, once I leave it for a few hours (happens at varying times of the day), I would like to be able to issue a command that puts the computer in this mode. Not sleep mode, not hibernate mode. Monitor off, that is all. I realize of course I could just turn the physical monitor off. That is not what I want. This Dell monitor takes forever to display a picture from a cold state. If it is turned off by the computer not sending a signal - not so bad. Is there any way for me to do this? As mentioned, the OS can do it, so I would find it really useful if I could do it too. :)

    Read the article

  • Pull network or power? (for contianing a rooted server)

    - by Aleksandr Levchuk
    When a server gets rooted (e.g. a situation like this), one of the first things that you may decide to do is containment. Some security specialists advise not to enter remediation immediately and to keep the server online until forensics are completed. Those advises are usually for APT. It's different if you have occasional Script kiddie breaches. However, you may decide to remediate (fix things) early and one of the steps in remediation is containment of the server. Quoting from Robert Moir's Answer - "disconnect the victim from its muggers". A server can be contained by pulling the network cable or the power cable. Which method is better? Taking into consideration the need for: Protecting victims from further damage Executing successful forensics (Possibly) Protecting valuable data on the server Edit: 5 assumptions Assuming: You detected early: 24 hours. You want to recover early: 3 days of 1 systems admin on the job (forensics and recovery). The server is not a Virtual Machine or a Container able to take a snapshot capturing the contents of the servers memory. You decide not to attempt prosecuting. You suspect that the attacker may be using some form of software (possibly sophisticated) and this software is still running on the server.

    Read the article

  • Running two graphics cards (non-SLI) to power 3D on two different monitors?

    - by Delameko
    Hi, I'm a bit clueless about this, so excuse my naivety. I have two video cards, a Nvidia 8800 and a GT120, powering three monitors. I run two 3D game instances (two Everquest 2 clients), one on each of my first two monitors. It's been running fine, although sometimes it sounds like the computer is trying to take off. Today I realised that I was actually playing them on the two monitors that are both powered by the 8800. Thinking that I might as well make use of the power of both cards I tried switching the monitor cables over so that each card would be "powering" one of the clients. (Is it silly to assume this is how it works?) This doesn't seem to have had the desired effect, as the client running on the 8800 screen is running worse than it was before. Is it even possible to run two clients on separate GPUs? Is SLI the only way to utilise 2 GPUs? Is there something special I have to do? Or do I have to set the client to use a particular GPU (an option I can't seem to find in EQ2)? I run the clients in window mode if that makes any difference, and I'm running Win 7. Thanks.

    Read the article

  • If incentive pay is considered harmful, what are the other options? [closed]

    - by Ricardo Cardona Ramirez
    Possible Duplicate: What kind of innovative non-cash financial benefits do I offer to my developers to retain them along with a competitive salary? I recently read about incentive payments and their consequences. In our company we have a bonus according to the developer's performance, but it has brought many problems, such as those described in the article. If the subsidies are damaging, what choice do we have?

    Read the article

  • What are the options for setting up a UNIX environment to learn C using Kernighan and Richie's The C Programming Language?

    - by ssbrewster
    I'm a novice programmer and have been experimenting with Javascript, jQuery and PHP but felt I wasn't getting a real depth of understanding of what I was doing. So, after reading Joel Spolsky's response to a question on this site (which I can't find now!), I took it back to basics and read Charles Petzold's 'Code' and am about to move onto Kernighan and Richie's The C Programming Language. I want to learn this in a UNIX environment but only have access to a Windows system. I have Ubuntu 12.04 running on a virtualised machine via VMWare Player, and done some coding in the terminal. Is using a Linux distro the only option for programming in a UNIX environment on Windows? And what are the next steps to start programming in C in UNIX and where do I get a compiler from?

    Read the article

  • What are the possible options for AI path-finding etc when the world is "partitionned"?

    - by Sebastien Diot
    If you anticipate a large persistent game world, and you don't want to end up with some game server crashing due to overload, then you have to design from the ground up a game world that is partitioned in chunks. This is in particular true if you want to run your game servers in the cloud, where each individual VM is relatively week, and memory and CPU are at a premium. I think the biggest challenge here is that the player receives all the parts around the location of the avatar, but mobs/monsters are normally located in the server itself, and can only directly access the data about the part of the world that the server own. So how can we make the AI behave realistically in that context? It can send queries to the other servers that own the neighboring parts, but that sounds rather network intensive and latency prone. It would probably be more performant for each mob AI to be spread over the neighboring parts, and proactively send the relevant info to the part that contains the actual mob atm. That would also reduce the stress in a mob crossing a border between two parts, and therefore "switching server". Have you heard of any AI design that solves those issues? Some kind of distributed AI brain? Maybe some kind of "agent" community working together through message passing?

    Read the article

< Previous Page | 68 69 70 71 72 73 74 75 76 77 78 79  | Next Page >