Search Results

Search found 13451 results on 539 pages for 'physical environment'.

Page 74/539 | < Previous Page | 70 71 72 73 74 75 76 77 78 79 80 81  | Next Page >

  • WiFi stops working after a while in Lenovo ThinkPad W520 (Ubuntu 12.04)

    - by el10780
    After several minutes(I do not know how many) there is no internet connection on my laptop via Wi-Fi.Ubuntu doesn't show any kind of message that my WiFi was disconnected neither there is a signal drop,but suddenly Firefox stops connecting to web pages.I checked my modem/router and it seems that it is working fine.I tried also to reboot the WiFi device and nothing happens.The only thing that it makes it work again is a reboot of the system and if I do not want to do a reboot then I am enforced to connect to the Internet using Ethernet cable.Does anybody know what is happening? ## Some Hardware info that might be helpful ## el10780@ThinkPad-W520:~$ sudo lshw -class network *-network description: Ethernet interface product: 82579LM Gigabit Network Connection vendor: Intel Corporation physical id: 19 bus info: pci@0000:00:19.0 logical name: eth0 version: 04 serial: f0:de:f1:f1:be:10 size: 100Mbit/s capacity: 1Gbit/s width: 32 bits clock: 33MHz capabilities: pm msi bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=e1000e driverversion=1.5.1-k duplex=full firmware=0.13-3 ip=192.168.0.10 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:50 memory:f3a00000-f3a1ffff memory:f3a2b000-f3a2bfff ioport:6080(size=32) *-network description: Wireless interface product: Centrino Advanced-N + WiMAX 6250 vendor: Intel Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: wlan0 version: 5e serial: 64:80:99:63:14:74 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlwifi driverversion=3.2.0-26-generic firmware=41.28.5.1 build 33926 ip=192.168.0.6 latency=0 link=yes multicast=yes wireless=IEEE 802.11abgn resources: irq:52 memory:f3900000-f3901fff *-network description: Ethernet interface physical id: 1 bus info: usb@2:1.3 logical name: wmx0 serial: 00:1d:e1:53:b2:e8 capabilities: ethernet physical configuration: driver=i2400m firmware=i6050-fw-usb-1.5.sbcf link=no el10780@ThinkPad-W520:~$ lspci 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:16.0 Communication controller: Intel Corporation 6 Series/C200 Series Chipset Family MEI Controller #1 (rev 04) 00:16.3 Serial controller: Intel Corporation 6 Series/C200 Series Chipset Family KT Controller (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579LM Gigabit Network Connection (rev 04) 00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation 6 Series/C200 Series Chipset Family High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b4) 00:1c.1 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 2 (rev b4) 00:1c.3 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 4 (rev b4) 00:1c.4 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 5 (rev b4) 00:1c.6 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 7 (rev b4) 00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation QM67 Express Chipset Family LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller (rev 04) 00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation GF108 [Quadro 1000M] (rev a1) 03:00.0 Network controller: Intel Corporation Centrino Advanced-N + WiMAX 6250 (rev 5e) 0d:00.0 System peripheral: Ricoh Co Ltd Device e823 (rev 08) 0d:00.3 FireWire (IEEE 1394): Ricoh Co Ltd R5C832 PCIe IEEE 1394 Controller (rev 04) 0e:00.0 USB controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) el10780@ThinkPad-W520:~$ rfkill list all 0: hci0: Bluetooth Soft blocked: no Hard blocked: no 1: tpacpi_bluetooth_sw: Bluetooth Soft blocked: no Hard blocked: no 2: phy0: Wireless LAN Soft blocked: no Hard blocked: no 3: i2400m-usb:2-1.3:1.0: WiMAX Soft blocked: yes Hard blocked: no The weirdest thing is this screenshot which I took after running the **Additional Drivers** program.I mean I have a NVidia Quadro 1000M and my Intel Centrino WiFi Card and this shows that there are not proprietay drivers for my system. http://imageshack.us/photo/my-images/268/screenshotfrom201207062.png/

    Read the article

  • My LAN USB NIC is not working in ubuntu 11.10?

    - by Gaurav_Java
    Today i start my system its seems that my LAN port is not working . so i buy one USB to LAN adapter and i plug in ubuntu system its doen't connect automatically .when i check result lsusb its shows me that there is one DM9601 Ethernet adapter is connected when i click on network information in panel its shows me that there is something " wired NEtwork (Broadcom NetLink BCM5784M gigabit Ethernet PCIe) I think want some driver for that .i don't have any idea how it can be used ? here output of sudo lspci -nn *00:00.0 Host bridge [0600]: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub [8086:2a40] (rev 07) 00:02.0 VGA compatible controller [0300]: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller [8086:2a42] (rev 07) 00:02.1 Display controller [0380]: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller [8086:2a43] (rev 07) 00:1a.0 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 [8086:2937] (rev 03) 00:1a.1 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 [8086:2938] (rev 03) 00:1a.7 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 [8086:293c] (rev 03) 00:1b.0 Audio device [0403]: Intel Corporation 82801I (ICH9 Family) HD Audio Controller [8086:293e] (rev 03) 00:1c.0 PCI bridge [0604]: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 [8086:2940] (rev 03) 00:1c.1 PCI bridge [0604]: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 [8086:2942] (rev 03) 00:1c.2 PCI bridge [0604]: Intel Corporation 82801I (ICH9 Family) PCI Express Port 3 [8086:2944] (rev 03) 00:1c.4 PCI bridge [0604]: Intel Corporation 82801I (ICH9 Family) PCI Express Port 5 [8086:2948] (rev 03) 00:1d.0 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 [8086:2934] (rev 03) 00:1d.1 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 [8086:2935] (rev 03) 00:1d.2 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 [8086:2936] (rev 03) 00:1d.3 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 [8086:2939] (rev 03) 00:1d.7 USB Controller [0c03]: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 [8086:293a] (rev 03) 00:1e.0 PCI bridge [0604]: Intel Corporation 82801 Mobile PCI Bridge [8086:2448] (rev 93) 00:1f.0 ISA bridge [0601]: Intel Corporation ICH9M LPC Interface Controller [8086:2919] (rev 03) 00:1f.2 SATA controller [0106]: Intel Corporation ICH9M/M-E SATA AHCI Controller [8086:2929] (rev 03) 00:1f.3 SMBus [0c05]: Intel Corporation 82801I (ICH9 Family) SMBus Controller [8086:2930] (rev 03) 02:00.0 Ethernet controller [0200]: Broadcom Corporation NetLink BCM5784M Gigabit Ethernet PCIe [14e4:1698] (rev 10) 04:00.0 Network controller [0280]: Intel Corporation WiFi Link 5100 [8086:4232]* sudo lshw -class network *-network description: Ethernet interface product: NetLink BCM5784M Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth0 version: 10 serial: 00:1f:16:9a:56:98 capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.119 firmware=sb v2.19 latency=0 link=no multicast=yes port=twisted pair resources: irq:47 memory:f4500000-f450ffff *-network DISABLED description: Wireless interface product: WiFi Link 5100 vendor: Intel Corporation physical id: 0 bus info: pci@0000:04:00.0 logical name: wlan0 version: 00 serial: 00:22:fa:09:02:00 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlagn driverversion=3.0.0-17-generic firmware=8.83.5.1 build 33692 latency=0 link=no multicast=yes wireless=IEEE 802.11abgn resources: irq:46 memory:f4600000-f4601fff *-network description: Ethernet interface physical id: 4 logical name: eth1 serial: 00:60:6e:00:f1:7d size: 100Mbit/s capacity: 100Mbit/s capabilities: ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=dm9601 driverversion=22-Aug-2005 duplex=full firmware=Davicom DM9601 USB Ethernet ip=192.168.1.34 link=yes multicast=yes port=MII speed=100Mbit/s I am using Wimax internet connection which i have to connect from browser . at that time my system is not showing that i am connected to any wired connection. but when i connect internet from other system after getting conneted to internet . when i plug again my USB LAN then its shows that you are conneted to wired connetion. here is screenshot for conneting wimax from browser after connecting to internet network connection shows

    Read the article

  • How to sell logistical procedures that require less time to perform but more finesse?

    - by foampile
    I am working with a group where part of the responsibilities is managing a certain set of configuration files which, of course, have the same skeleton/structure across different environments but different values (like server, user, this setting, that setting etc.). Pretty classic scenario... The problem is that everyone just goes and modifies final, environment-specific files and basically repeats the work for every environment. Personally, I am offended to have to peform repeatable, mundane tasks in this day and age when we have technologies to automate it all. So I devised a very simple procedure of abstracting the files into templates, stubbing env-specific values with parameters and then wrote a simple Perl script that, given a template and an environment matrix with env-specific values for each param, produces the final file. So this is nothing special, cutting-edge or revolutionary -- I am pretty sure that 20 years ago efficient places did their CM like that. However, that requires that changes are made at the template level and then distributed across different environments using the script and not making changes in the final environment-specific files. This is where I am encountering resentment as they feel "comfortable" doing it their old, manual, repeated labor way. Personally, I don't have a problem with them working hard rather than smart but the problem is when I have to build on top of someone else's changes, I have to merge their changes into my template from a specific file, which takes time and is grueling. So my question is how to go about selling my method, which makes it so much faster in an environment that is resentful to change and where most things have to be done at the level of the least competent team member?

    Read the article

  • Time to Get Started with Oracle Data Integrator 12c!

    - by Sandrine Riley
    v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} It is time to get started with Oracle Data Integrator 12c! We would like to highlight for you a great place to begin your journey with ODI.  Here you will find the Getting Started section for ODI, which provides a few options. v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} w\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;} Step 1 – Start by downloading the Getting Started (PDF). The document provides general background information and detailed examples to help you learn how to use Oracle Data Integrator. This document guides you through a first project with Oracle Data Integrator 12c, and the instructions in this document are required for using the Getting Started Demonstration Environment. If you would like to run the Getting Started Demonstration Environment on your system go to Step 2 A. If you would like to run the Getting Started Demonstration Environment installed and pre-configured in a Virtual Image, go to Step 2 B. Step 2 - A-   A -  If you would like to run the Getting Started Demo Environment on your system, you will want to then download the Demo Environment for Getting Started (ZIP) archive containing ODI metadata, configuration scripts and sample data. B-   B -  Alternatively, a pre-configured virtual machine is available with the Getting Started installation and configuration. The Virtual Machine platform uses Oracle Virtual Box technology, and use of this configuration would necessitate the download/installation of Virtual Box and the Getting Started virtual machine. If you prefer this route and would rather run the Getting Started Demonstration Environment installed and preconfigured in a Virtual Machine, please download the ODI 12c Getting Started Virtual Machine. Step 3 – In continuation with the Getting Started Demonstration Environment and the Getting Started Guide, you will now be able to run through a first project with Oracle Data Integrator. Now that you have successfully done the exercises above, you may want to play on your own, and develop with Oracle Data Integrator on your environment...  here you can download a full version of Oracle Data Integrator 12c.  Enjoy, and happy developing! Learn more about Oracle Data Integrator; including FAQ, the Oracle by Example Series, Sample Code, and White Papers. Normal 0 false false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}

    Read the article

  • Migration a database from 32bit to 64bit

    - by Mike Dietrich
    Database migrations from an 32bit environment to an 64bit environment keeping the same platform architecture (e.g. moving an Oracle 10.2.0.5 database from MS Windows XP 32bit to MS Windows Server 2003 64bit) does not happen that often anymore. But still we see them getting done. And there are a few things to note when doing such a move. First of all the important question is:Will you upgrade your database as part of this move - Yes or No? If you say "Yes" then you are almost done with that topic as we will take care of that bitnes move during the upgrade. The only thing you have to take care is OLAP in case you are using OLAP Option with Analytic Workspaces (AW) by yourself. Those store data in Binary LOBs - and in order to move AWs from 32bit to 64bit you have to export your AWs prior to the move - and import them later on. People who don't use OLAP don't have to take care on this. But if you say "No" (meaning: no upgrade actions involved - you keep your database version) then you have to make sure to invalidate all packages and stored code in the database before you shutdown your database in the 32bit environment and prior to moving it over. And the same rule as above for OLAP applies once you use the OLAP Option. In the source environment: startup upgrade;    -- [or startup migrate; -- for Oracle 9i] @?/rdbms/admin/utlirp.sqlshutdown immediate In the destination environment: startup upgrade @?/olap/admin/xumuts.plb --Only if OLAP Option is installed@?/rdbms/admin/utlrp.sql The script utlirp.sql will invalidate all packages and stored code, utlrp.sql will recompile - and xumuts.plb will rebuild the OLAP Analytic Workspaces in case you have the OLAP Option installed.

    Read the article

  • How one could use a live editor

    - by Sathvik
    I was thinking about a live editing environment where code / a source file is synchronized so that, changes made by one user would be carried across to all others editing the file. Something like Google Wave, but for code. Could this kind of an environment be better for the code, as changes are shared instantly? (with revision-control, of course) Has anyone tried (or has had a need for) using a shared environment for code?

    Read the article

  • List of rich web application technologies

    - by Michal Czardybon
    I am trying to get myself acquainted with the world of rich web application. There are some comparison tables of available technologies on the Wikipedia, but I still find it unclear what are the options for rich application development. Could you please verify and complete the information I gathered below? What are the key pros and cons of each option? Which is the best choice for big and very rich web application? Option 1: ASP.NET/ASP.NET MVC Vendor: Microsoft Environment: Visual Studio Language: C# Output: HTML+JavaScript+AJAX Example: www.stackoverflow.com Option 2: Silverlight Vendor: Microsoft Environment: Visual Studio Language: C# Output: .NET executable? Example: ? Option 3: Google Web Toolkit Vendor: Google Environment: Eclipse Language: Java Output: HTML+JavaScript+AJAX Example: http://www.projectkaiser.com:8080/pk/ Option 4: Flex Vendor: Adobe Environment: ? Language: ? Output: Flash (.swf file) Example: http://listen.grooveshark.com/ Option 5: Adobe AIR Vendor: Adobe Environment: ? Language: ? Output: AIR Example: http://www.colabolo.com/en/download.html Option 5: Ruby on Rails Vendor: Rails Core Team Envirnoment: ? Language: Ruby Output: HTML+JavaScript+AJAX? Example: ? Option 6: Java Applets Vendor: Sun Environment: Eclipse Language: Java Output: Java Applet Option 7: OpenLeszlo Vendor: ? Environment: ? Language: ? Output: ? Example: ? Option 8: Python? ??? Option 9: XUL ???

    Read the article

  • How can I modify/merge Jinja2 dictionaries?

    - by Brian M. Hunt
    I have a Jinja2 dictionary and I want a single expression that modifies it - either by changing its content, or merging with another dictionary. >>> import jinja2 >>> e = jinja2.Environment() Modify a dict: Fails. >>> e.from_string("{{ x[4]=5 }}").render({'x':{1:2,2:3}}) Traceback (most recent call last): File "<stdin>", line 1, in <module> File "jinja2/environment.py", line 743, in from_string return cls.from_code(self, self.compile(source), globals, None) File "jinja2/environment.py", line 469, in compile self.handle_exception(exc_info, source_hint=source) File "<unknown>", line 1, in template jinja2.exceptions.TemplateSyntaxError: expected token 'end of print statement', got '=' Two-stage update: Prints superfluous "None". >>> e.from_string("{{ x.update({4:5}) }} {{ x }}").render({'x':{1:2,2:3}}) u'None {1: 2, 2: 3, 4: 5}' >>> e.from_string("{{ dict(x.items()+ {3:4}.items()) }}").render({'x':{1:2,2:3}}) Traceback (most recent call last): File "<stdin>", line 1, in <module> File "jinja2/environment.py", line 868, in render return self.environment.handle_exception(exc_info, True) File "<template>", line 1, in top-level template code TypeError: <lambda>() takes exactly 0 arguments (1 given) Use dict(x,**y): Fails. >>> e.from_string("{{ dict((3,4), **x) }}").render({'x':{1:2,2:3}}) Traceback (most recent call last): File "<stdin>", line 1, in <module> File "jinja2/environment.py", line 868, in render return self.environment.handle_exception(exc_info, True) File "<template>", line 1, in top-level template code TypeError: call() keywords must be strings So how does one modify the dictionary x in Jinja2 by changing an attribute or merging with another dictionary? This question is similar to: How can I merge two Python dictionaries as a single expression? -- insofar as Jinja2 and Python are analogous.

    Read the article

  • 64-bit 13.10 shows 1GB less RAM than 64-bit 13.04 did

    - by kiloseven
    Multiple 64-bit versions (Kubuntu, Lubuntu and Xubuntu) once installed on my ThinkPad R60 show 3GB of RAM, not the correct 4GB of RAM. Last week with 13.04, I had 4GB of RAM (which matches the BIOS) and this week I have 3GB available. Inquiring minds want to know. Details follow: Linux R60 3.11.0-12-generic #19-Ubuntu SMP Wed Oct 9 16:20:46 UTC 2013 x86_64 x86_64 x86_64 GNU/Linux r60 free -m reports: _ total used free shared buffers cached Mem: 3001 854 2146 0 22 486 -/+ buffers/cache: 346 2655 Swap: 0 0 0 . . . . . . lshw shows: description: Notebook product: 9459AT8 () vendor: LENOVO version: ThinkPad R60/R60i serial: redacted width: 64 bits capabilities: smbios-2.4 dmi-2.4 vsyscall32 configuration: administrator_password=disabled boot=normal chassis=notebook family=ThinkPad R60/R60i frontpanel_password=unknown keyboard_password=disabled power-on_password=disabled uuid=126E4001-48CA-11CB-9D53-B982AE0D1ABB *-core description: Motherboard product: 9459AT8 vendor: LENOVO physical id: 0 version: Not Available *-firmware description: BIOS vendor: LENOVO physical id: 0 version: 7CETC1WW (2.11 ) date: 01/09/2007 size: 144KiB capacity: 1984KiB capabilities: pci pcmcia pnp upgrade shadowing escd cdboot bootselect socketedrom edd acpi usb biosbootspecification {snip} *-memory description: System Memory physical id: 29 slot: System board or motherboard size: 4GiB *-bank:0 description: SODIMM DDR2 Synchronous physical id: 0 slot: DIMM 1 size: 2GiB width: 64 bits *-bank:1 description: SODIMM DDR2 Synchronous physical id: 1 slot: DIMM 2 size: 2GiB width: 64 bits dpkg -l linux-* returns: Desired=Unknown/Install/Remove/Purge/Hold | Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend |/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad) ||/ Name Version Description +++-======================================-=======================================-========================================================================== un linux-doc-3.2.0 (no description available) ii linux-firmware 1.79.6 Firmware for Linux kernel drivers ii linux-generic 3.2.0.52.62 Complete Generic Linux kernel un linux-headers (no description available) un linux-headers-3 (no description available) un linux-headers-3.0 (no description available) un linux-headers-3.2.0-23 (no description available) un linux-headers-3.2.0-23-generic (no description available) ii linux-headers-3.2.0-52 3.2.0-52.78 Header files related to Linux kernel version 3.2.0 ii linux-headers-3.2.0-52-generic 3.2.0-52.78 Linux kernel headers for version 3.2.0 on 64 bit x86 SMP ii linux-headers-generic 3.2.0.52.62 Generic Linux kernel headers un linux-image (no description available) un linux-image-3.0 (no description available) ii linux-image-3.2.0-52-generic 3.2.0-52.78 Linux kernel image for version 3.2.0 on 64 bit x86 SMP ii linux-image-generic 3.2.0.52.62 Generic Linux kernel image un linux-initramfs-tool (no description available) un linux-kernel-headers (no description available) un linux-kernel-log-daemon (no description available) ii linux-libc-dev 3.2.0-52.78 Linux Kernel Headers for development un linux-restricted-common (no description available) ii linux-sound-base 1.0.25+dfsg-0ubuntu1.1 base package for ALSA and OSS sound systems un linux-source-3.2.0 (no description available) un linux-tools (no description available)

    Read the article

  • wifi problems with lenovo g580 on kubuntu-13.04-desktop-amd64

    - by user203963
    i have a wifi connection problem in lenovo g580 on kubuntu-13.04-desktop-amd64. ethernet cable is working properly but wifi does'nt connect below are some hardware information sudo lshw -class network gives *-network description: Ethernet interface product: AR8162 Fast Ethernet vendor: Qualcomm Atheros physical id: 0 bus info: pci@0000:01:00.0 logical name: eth0 version: 10 serial: 20:89:84:3d:e9:10 size: 100Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm pciexpress msi msix bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=alx driverversion=1.2.3 duplex=full firmware=N/A ip=192.168.0.106 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:16 memory:90500000-9053ffff ioport:2000(size=128) *-network description: Network controller product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 version: 01 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=bcma-pci-bridge latency=0 resources: irq:17 memory:90400000-90403fff *-network description: Wireless interface physical id: 3 logical name: wlan0 serial: 68:94:23:fa:2c:d9 capabilities: ethernet physical wireless configuration: broadcast=yes driver=brcmsmac driverversion=3.8.0-19-generic firmware=N/A link=no multicast=yes wireless=IEEE 802.11bgn lsubs gives Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 003: ID 0489:e032 Foxconn / Hon Hai Bus 002 Device 003: ID 04f2:b2e2 Chicony Electronics Co., Ltd lspci gives 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:14.0 USB controller: Intel Corporation 7 Series/C210 Series Chipset Family USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation 7 Series/C210 Series Chipset Family MEI Controller #1 (rev 04) 00:1a.0 USB controller: Intel Corporation 7 Series/C210 Series Chipset Family USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation 7 Series/C210 Series Chipset Family High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation 7 Series/C210 Series Chipset Family PCI Express Root Port 1 (rev c4) 00:1c.1 PCI bridge: Intel Corporation 7 Series/C210 Series Chipset Family PCI Express Root Port 2 (rev c4) 00:1d.0 USB controller: Intel Corporation 7 Series/C210 Series Chipset Family USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation HM76 Express Chipset LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation 7 Series Chipset Family 6-port SATA Controller [AHCI mode] (rev 04) 00:1f.3 SMBus: Intel Corporation 7 Series/C210 Series Chipset Family SMBus Controller (rev 04) 01:00.0 Ethernet controller: Qualcomm Atheros AR8162 Fast Ethernet (rev 10) 02:00.0 Network controller: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller (rev 01) Does anyone knows the solution? rfkill list all gives 0: hci0: Bluetooth Soft blocked: no Hard blocked: no 1: phy0: Wireless LAN Soft blocked: yes Hard blocked: no 2: ideapad_wlan: Wireless LAN Soft blocked: yes Hard blocked: no 3: ideapad_bluetooth: Bluetooth Soft blocked: no Hard blocked: no

    Read the article

  • Unable to use factory girl with Cucumber and rails 3 (bundler problem)

    - by jbpros
    Hi there, I'm trying to run cucumber features with factory girl factories on a fresh Rails 3 application. Here is my Gemfile: source "http://gemcutter.org" gem "rails", "3.0.0.beta" gem "pg" gem "factory_girl", :git => "git://github.com/thoughtbot/factory_girl.git", :branch => "rails3" gem "rspec-rails", ">= 2.0.0.beta.4" gem "capybara" gem "database_cleaner" gem "cucumber-rails", :require => false Then the bundle install commande just runs smoothly: $ bundle install /usr/lib/ruby/gems/1.8/gems/bundler-0.9.3/lib/bundler/installer.rb:81:Warning: Gem::Dependency#version_requirements is deprecated and will be removed on or after August 2010. Use #requirement Updating git://github.com/thoughtbot/factory_girl.git Fetching source index from http://gemcutter.org Resolving dependencies Installing abstract (1.0.0) from system gems Installing actionmailer (3.0.0.beta) from system gems Installing actionpack (3.0.0.beta) from system gems Installing activemodel (3.0.0.beta) from system gems Installing activerecord (3.0.0.beta) from system gems Installing activeresource (3.0.0.beta) from system gems Installing activesupport (3.0.0.beta) from system gems Installing arel (0.2.1) from system gems Installing builder (2.1.2) from system gems Installing bundler (0.9.13) from system gems Installing capybara (0.3.6) from system gems Installing cucumber (0.6.3) from system gems Installing cucumber-rails (0.3.0) from system gems Installing culerity (0.2.9) from system gems Installing database_cleaner (0.5.0) from system gems Installing diff-lcs (1.1.2) from system gems Installing erubis (2.6.5) from system gems Installing factory_girl (1.2.3) from git://github.com/thoughtbot/factory_girl.git (at rails3) Installing ffi (0.6.3) from system gems Installing i18n (0.3.6) from system gems Installing json_pure (1.2.3) from system gems Installing mail (2.1.3) from system gems Installing memcache-client (1.7.8) from system gems Installing mime-types (1.16) from system gems Installing nokogiri (1.4.1) from system gems Installing pg (0.9.0) from system gems Installing polyglot (0.3.0) from system gems Installing rack (1.1.0) from system gems Installing rack-mount (0.4.7) from system gems Installing rack-test (0.5.3) from system gems Installing rails (3.0.0.beta) from system gems Installing railties (3.0.0.beta) from system gems Installing rake (0.8.7) from system gems Installing rspec (2.0.0.beta.4) from system gems Installing rspec-core (2.0.0.beta.4) from system gems Installing rspec-expectations (2.0.0.beta.4) from system gems Installing rspec-mocks (2.0.0.beta.4) from system gems Installing rspec-rails (2.0.0.beta.4) from system gems Installing selenium-webdriver (0.0.17) from system gems Installing term-ansicolor (1.0.5) from system gems Installing text-format (1.0.0) from system gems Installing text-hyphen (1.0.0) from system gems Installing thor (0.13.4) from system gems Installing treetop (1.4.4) from system gems Installing tzinfo (0.3.17) from system gems Installing webrat (0.7.0) from system gems Your bundle is complete! When I run cucumber, here is the error I get: $ rake cucumber (in /home/jbpros/projects/deorbitburn) /usr/lib/ruby/gems/1.8/gems/bundler-0.9.3/lib/bundler/resolver.rb:97:Warning: Gem::Dependency#version_requirements is deprecated and will be removed on or after August 2010. Use #requirement NOTICE: CREATE TABLE will create implicit sequence "posts_id_seq" for serial column "posts.id" NOTICE: CREATE TABLE / PRIMARY KEY will create implicit index "posts_pkey" for table "posts" /usr/bin/ruby1.8 -I "/usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/lib:lib" "/usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/cucumber" --profile default Using the default profile... git://github.com/thoughtbot/factory_girl.git (at rails3) is not checked out. Please run `bundle install` (Bundler::PathError) /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/source.rb:282:in `load_spec_files' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/source.rb:190:in `local_specs' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:36:in `runtime_gems' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:35:in `each' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:35:in `runtime_gems' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/index.rb:5:in `build' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:34:in `runtime_gems' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:14:in `index' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/index.rb:5:in `build' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:13:in `index' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:55:in `resolve_locally' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:28:in `specs' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:65:in `specs_for' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/environment.rb:23:in `requested_specs' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler/runtime.rb:18:in `setup' /home/jbpros/.bundle/gems/bundler-0.9.13/lib/bundler.rb:68:in `setup' /home/jbpros/projects/deorbitburn/config/boot.rb:7 /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `gem_original_require' /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `polyglot_original_require' /usr/lib/ruby/gems/1.8/gems/polyglot-0.3.0/lib/polyglot.rb:65:in `require' /home/jbpros/projects/deorbitburn/config/application.rb:1 /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `gem_original_require' /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `polyglot_original_require' /usr/lib/ruby/gems/1.8/gems/polyglot-0.3.0/lib/polyglot.rb:65:in `require' /home/jbpros/projects/deorbitburn/config/environment.rb:2 /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `gem_original_require' /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `polyglot_original_require' /usr/lib/ruby/gems/1.8/gems/polyglot-0.3.0/lib/polyglot.rb:65:in `require' /home/jbpros/projects/deorbitburn/features/support/env.rb:8 /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `gem_original_require' /usr/local/lib/site_ruby/1.8/rubygems/custom_require.rb:31:in `polyglot_original_require' /usr/lib/ruby/gems/1.8/gems/polyglot-0.3.0/lib/polyglot.rb:65:in `require' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/rb_support/rb_language.rb:124:in `load_code_file' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/step_mother.rb:85:in `load_code_file' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/step_mother.rb:77:in `load_code_files' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/step_mother.rb:76:in `each' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/step_mother.rb:76:in `load_code_files' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/cli/main.rb:48:in `execute!' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/../lib/cucumber/cli/main.rb:20:in `execute' /usr/lib/ruby/gems/1.8/gems/cucumber-0.6.3/bin/cucumber:8 rake aborted! Command failed with status (1): [/usr/bin/ruby1.8 -I "/usr/lib/ruby/gems/1....] (See full trace by running task with --trace) Do I have to do something special for bundler to check out factory girl's repository on github?

    Read the article

  • What is my miniport's service name?

    - by Ian Boyd
    i am trying to query the physical sector size of my drive using fsutil: C:\Windows\system32>fsutil fsinfo ntfsinfo c: NTFS Volume Serial Number : 0x78cc11b2cc116c1e Version : 3.1 Number Sectors : 0x000000003a382fff Total Clusters : 0x00000000074705ff Free Clusters : 0x00000000022fc29b Total Reserved : 0x00000000000007d0 Bytes Per Sector : 512 Bytes Per Physical Sector : <Not Supported> Bytes Per Cluster : 4096 Bytes Per FileRecord Segment : 1024 Clusters Per FileRecord Segment : 0 Mft Valid Data Length : 0x00000000305c0000 Mft Start Lcn : 0x00000000000c0000 Mft2 Start Lcn : 0x0000000003a382ff Mft Zone Start : 0x0000000006951940 Mft Zone End : 0x0000000006951c80 RM Identifier: 19B22CBE-570D-19DE-9C72-CD758F800DDC You can see that the Bytes Per Physical Sector value is Not Supported: Bytes Per Physical Sector : <Not Supported> In KB Article Microsoft support policy for 4K sector hard drives in Windows, Microsoft says: If fsutil.exe continues to display "Bytes Per Physical Sector : " after you apply the latest storage driver and the required hotfixes, make sure that the following registry path exists: HKLM\CurrentControlSet\Services\<miniport’s service name>\Parameters\Device\ Name: EnableQueryAccessAlignment Type: REG_DWORD Value: 1: Enable The only thing i don't know is what my Miniport's service name is. What is my miniport's service name. i know that my SATA drives are in AHCI mode, and AHCI uses the msahci driver service: Is that my miniport service? "MSAHCI"? See also Hitachi - Advanced Format Technology Brief RMPrepUSB - Advanced Format (4K sector) hard disks Microsoft support policy for 4K sector hard drives in Windows OSR Online - Advance Disk Format support in Storport Virtual Mniport diver Default cluster size for NTFS, FAT, and exFAT Wikipedia - Advanced Format

    Read the article

  • SQL Server Licensing in a VMware vSphere Cluster

    - by Helvick
    If I have SQL Server 2008 instances running in virtual machines on a VMware vSphere cluster with vMotion\DRS enabled so that the VM's can (potentially) run on any one of the physical servers in the cluster what precisely are the license requirements? For example assume that I have 4 physical ESX Hosts with dual physical CPU's and 3 separate single vCPU Virtual Machines running SQL Server 2008 running in that cluster. How many SQL Standard Processor licenses would I need? Is it 3 (one per VM) or 12 (one per VM on each physical host) or something else? How many SQL Enterprise Processor licenses would I need? Is it 3 (one per VM) or 8 (one for each physical CPU in the cluster) or, again, something else? The range in the list prices for these options goes from $17k to $200k so getting it right is quite important. Bonus question: If I choose the Server+CAL licensing model do I need to buy multiple Server instance licenses for each of the ESX hosts (so 12 copies of the SQL Server Standard server license so that there are enough licenses on each host to run all VM's) or again can I just license the VM and what difference would using Enterprise per server licensing make? Edited to Add Having spent some time reading the SQL 2008 Licensing Guide (63 Pages! Includes Maps!*) I've come across this: • Under the Server/CAL model, you may run unlimited instances of SQL Server 2008 Enterprise within the server farm, and move those instances freely, as long as those instances are not running on more servers than the number of licenses assigned to the server farm. • Under the Per Processor model, you effectively count the greatest number of physical processors that may support running instances of SQL Server 2008 Enterprise at any one time across the server farm and assign that number of Processor licenses And earlier: ..For SQL Server, these rule changes apply to SQL Server 2008 Enterprise only. By my reading this means that for my 3 VM's I only need 3 SQL 2008 Enterprise Processor Licenses or one copy of Server Enterprise + CALs for the cluster. By implication it means that I have to license all processors if I choose SQL 2008 Standard Processor licensing or that I have to buy a copy of SQL Server 2008 Standard for each ESX host if I choose to use CALs. *There is a map to demonstrate that a Server Farm cannot extend across an area broader than 3 timezones unless it's in the European Free Trade Area, I wasn't expecting that when I started reading it.

    Read the article

  • SQL Server Licensing in a VMware vSphere Cluster

    - by Helvick
    If I have SQL Server 2008 instances running in virtual machines on a VMware vSphere cluster with vMotion\DRS enabled so that the VM's can (potentially) run on any one of the physical servers in the cluster what precisely are the license requirements? For example assume that I have 4 physical ESX Hosts with dual physical CPU's and 3 separate single vCPU Virtual Machines running SQL Server 2008 running in that cluster. How many SQL Standard Processor licenses would I need? Is it 3 (one per VM) or 12 (one per VM on each physical host) or something else? How many SQL Enterprise Processor licenses would I need? Is it 3 (one per VM) or 8 (one for each physical CPU in the cluster) or, again, something else? The range in the list prices for these options goes from $17k to $200k so getting it right is quite important. Bonus question: If I choose the Server+CAL licensing model do I need to buy multiple Server instance licenses for each of the ESX hosts (so 12 copies of the SQL Server Standard server license so that there are enough licenses on each host to run all VM's) or again can I just license the VM and what difference would using Enterprise per server licensing make? Edited to Add Having spent some time reading the SQL 2008 Licensing Guide (63 Pages! Includes Maps!*) I've come across this: • Under the Server/CAL model, you may run unlimited instances of SQL Server 2008 Enterprise within the server farm, and move those instances freely, as long as those instances are not running on more servers than the number of licenses assigned to the server farm. • Under the Per Processor model, you effectively count the greatest number of physical processors that may support running instances of SQL Server 2008 Enterprise at any one time across the server farm and assign that number of Processor licenses And earlier: ..For SQL Server, these rule changes apply to SQL Server 2008 Enterprise only. By my reading this means that for my 3 VM's I only need 3 SQL 2008 Enterprise Processor Licenses or one copy of Server Enterprise + CALs for the cluster. By implication it means that I have to license all processors if I choose SQL 2008 Standard Processor licensing or that I have to buy a copy of SQL Server 2008 Standard for each ESX host if I choose to use CALs. *There is a map to demonstrate that a Server Farm cannot extend across an area broader than 3 timezones unless it's in the European Free Trade Area, I wasn't expecting that when I started reading it.

    Read the article

  • which package i should choose, if i want to install virtualenv for python?

    - by hugemeow
    pip search just returns so many matches, i am confused about which package i should choose to install .. should i only install virtualenv? or i'd better also install virtualenv-commands and virtualenv-commands, etc, but i really don't know exactly what virtualenv-commands is ... mirror0@lab:~$ pip search virtualenv virtualenvwrapper - Enhancements to virtualenv virtualenv - Virtual Python Environment builder veh - virtualenv for hg pyutilib.virtualenv - PyUtilib utility for building custom virtualenv bootstrap scripts. envbuilder - A package for automatic generation of virtualenvs virtstrap-core - A bootstrapping mechanism for virtualenv+pip and shell scripts tox - virtualenv-based automation of test activities virtualenvwrapper-win - Port of Doug Hellmann's virtualenvwrapper to Windows batch scripts everyapp.bootstrap - Enhanced virtualenv bootstrap script creation. orb - pip/virtualenv shell script wrapper monupco-virtualenv-python - monupco.com registration agent for stand-alone Python virtualenv applications virtualenvwrapper-powershell - Enhancements to virtualenv (for Windows). A clone of Doug Hellmann's virtualenvwrapper RVirtualEnv - relocatable python virtual environment virtualenv-clone - script to clone virtualenvs. virtualenvcontext - switch virtualenvs with a python context manager lessrb - Wrapper for ruby less so that it's in a virtualenv. carton - make self-extracting virtualenvs virtualenv5 - Virtual Python 3 Environment builder clever-alexis - Clever redhead girl that builds and packs Python project with Virtualenv into rpm, deb, etc. kforgeinstall - Virtualenv bootstrap script for KForge pypyenv - Install PyPy in virtualenv virtualenv-distribute - Virtual Python Environment builder virtualenvwrapper.project - virtualenvwrapper plugin to manage a project work directory virtualenv-commands - Additional commands for virtualenv. rjm.recipe.venv - zc.buildout recipe to turn the entire buildout tree into a virtualenv virtualenvwrapper.bitbucket - virtualenvwrapper plugin to manage a project work directory based on a BitBucket repository tg_bootstrap - Bootstrap a TurboGears app in a VirtualEnv django-env - Automaticly manages virtualenv for django project virtual-node - Install node.js into your virtualenv django-environment - A plugin for virtualenvwrapper that makes setting up and creating new Django environments easier. vip - vip is a simple library that makes your python aware of existing virtualenv underneath. virtualenvwrapper.django - virtualenvwrapper plugin to create a Django project work directory terrarium - Package and ship relocatable python virtualenvs venv_dependencies - Easy to install any dependencies in a virtualenviroment(without making symlinks by hand and etc...) virtualenv-sh - Convenient shell interface to virtualenv virtualenvwrapper.github - Plugin for virtualenvwrapper to automatically create projects based on github repositories. virtualenvwrapper.configvar - Plugin for virtualenvwrapper to automatically export config vars found in your project level .env file. virtualenvwrapper-emacs-desktop - virtualenvwrapper plugin to control emacs desktop mode bootstrapper - Bootstrap Python projects with virtualenv and pip. virtualenv3 - Obsolete fork of virtualenv isotoma.depends.zope2_13_8 - Running zope in a virtualenv virtual-less - Install lessc into your virtualenv virtualenvwrapper.tmpenv - Temporary virtualenvs are automatically deleted when deactivated isotoma.plone.heroku - Tooling for running Plone on heroku in a virtualenv gae-virtualenv - Using virtualenv with zipimport on Google App Engine pinvenv - VirtualEnv plugins for pin isotoma.depends.plone4_1 - Running plone in a virtualenv virtualenv-tools - A set of tools for virtualenv virtualenvwrapper.npm - Plugin for virtualenvwrapper to automatically encapsulate inside the virtual environment any npm installed globaly when the venv is activated d51.django.virtualenv.test_runner - Simple package for running isolated Django tests from within virtualenv difio-virtualenv-python - Difio registration agent for stand-alone Python virtualenv applications VirtualEnvManager - A package to manage various virtual environments. virtualenvwrapper.gem - Plugin for virtualenvwrapper to automatically encapsulate inside the virtual environment any gems installed when the venv is activated

    Read the article

  • How To Grant Folder permissions for WMSvc IIS

    - by LillyPop
    Im using Web Deploy with IIS7 and I want to grant permissions on a web site physical folder. Ive done this before (as I have another physical folder with r/w for WMSvc) but I have forgotten how I did it! When I go to the physical folder Security Tab Edit Add Object Name = WMSvc Check Names, I get 'An object named WMSvc cannot be found'?? I have the 'WMSvc' object listed fine in the 'Groups or usernames' on the other Folder I mentioned above. I feel a bit daft, what am I doing wrong, how can give folder permissions to WMSvc object on a physical folder?

    Read the article

  • Linked vSphere servers preventing cloning?

    - by brian
    I've currently got a pair of vSphere5 standard servers (physical, not VAs) managing about a hundred ESX 4.1 and 5 hosts in two different physical and logical datacenters. With our last purchase, we bought another vSphere license for the new vS server. I unmanaged all the ESX servers in one datacenter and added them to new vSphere server. Our previous single-vS-server layout used to be: -vSphere1 --Datacenter1 (where the physical ESX host was located) ---Folder ----ESX server1 --Datacenter2 ---Folder ----ESX server2 Now it looks like -vSphere1 --Datacenter1 ---Folder ----ESX server1 -vSphere2 (new vSphere server) --Datacenter2 ---Folder ----ESX server2 ESX server2 was removed from vSphere1's inventory and added to vSphere2's, so it is now managed by vSphere2. This is nice and all, as no vSphere <-- ESX management traffic leaves the physical datacenter, except for one huge oversight: when I go to clone a VM, the opposite vSphere server (and thus other datacenter) does not show up in the list on the first page of the wizard. Is this a bug, a license limitation, or is it just simply not possible to clone a VM from an ESX box managed by one vS server to another ESX box managed by a /different/ vS server?

    Read the article

  • Trac problem: AttributeError: Cannot find an implementation of the "IRequestHandler" interface named "WikiModule"

    - by Janosch
    This problem already has been described mutliple times in different mailing lists, but no solution has yet been published. My original setup is as follows (but in the mean time i have a simpler one on Windows 7): Ubuntu server with apache 2.2 and python 2.7 virutal python environment created with virtualenv installed babel, genshi and trac in this order using pip in the virtual environment Trac seems to run fine with tracd, but when visiting it through apache, i get the following error in an official trac error page: AttributeError: Cannot find an implementation of the "IRequestHandler" interface named "WikiModule" The stacktrace looks like this: Traceback (most recent call last): File "/srv/trac/python-environment/lib/python2.5/site-packages/Trac-0.13dev_r10668-py2.5.egg/trac/web/main.py",line 473, in _dispatch_request dispatcher.dispatch(req) File "/srv/trac/python-environment/lib/python2.5/site-packages/Trac-0.13dev_r10668-py2.5.egg/trac/web/main.py", line 154, in dispatch chosen_handler = self.default_handler File "/srv/trac/python-environment/lib/python2.5/site-packages/Trac-0.13dev_r10668-py2.5.egg/trac/config.py", line 691, in __get__ self.section, self.name)) AttributeError: Cannot find an implementation of the "IRequestHandler" interface named "WikiModule". Please update the option trac.default_handler in trac.ini. I already tried a lot to get down to the root of the problem, for me it looks as if all nativ trac components refuse to load. When one explicitely imports these components in the wsgi handler, some of them start to work somehow. Since i suspected the virtual environment, i dropped it, and manually copied all dependencies (babel, genshi, trac, ..) to one directory, and added this directory to system.path in the wsgi handler. I get exactly the same error. Since this setup is now independend from the environment, one can easily try it out on any other machine (windows or linux) running apache 2 and python 2.7. On my Windwos 7 machine, i got exactly the same problem. I zipped together the whole bundle, one can download it from http://www.xterity.de/tmp/trac-installation.zip . In the apache configuration (Windows 7 machine) i use the following settings: Alias /trac/chrome/common "D:/workspace/trac-installation/trac-resources/common" Alias /trac/chrome/site "D:/workspace/trac-installation/trac-resources/site" WSGIScriptAlias /trac "D:/workspace/trac-installation/apache/handler.wsgi" <Directory "D:/workspace/trac-installation/trac-resources"> Order allow,deny Allow from all </Directory> <Directory "D:/workspace/trac-installation"> Order allow,deny Allow from all </Directory> <Location "/trac"> Order allow,deny Allow from all </Location> And my handler.wsgi looks like this: import os import sys sys.path.append('D:/workspace/trac-installation/dependencies/') os.environ['TRAC_ENV'] = 'D:/workspace/trac-installation/trac-environments/Esp004' os.environ['PYTHON_EGG_CACHE'] = 'D:/workspace/trac-installation/eggs' import trac.web.main application = trac.web.main.dispatch_request Has anybody got an idea what could be the problem, or how to find out where it comes from?

    Read the article

  • VMWare Server - Writing files to virtual hard drive performance

    - by Ardman
    We have just moved our infrastructure from physical servers to virtual machines. Everything is running great and we are happy with the result of the move. We have identified one problem, and that is reading/writing performance. We have an application that compiles files and writes to disk. This is considerably slower on the new virtual machines compared to the physical machines. Is there a performance bottleneck when writing to a virtual hard drive compared to a physical hard drive?

    Read the article

  • Package upgrade on Ubuntu raid server and grub setup issue

    - by RecNes
    I have remote Ubuntu 10.10 server running on raid system. I did package upgrade yesterday night for security reasons. During the upgrade, grub installation screen appeared and asked me which partition I wanted to install grub. Options are sda,sdb,md1 and md2. I decide to install them on both sda and sdb partitions. I wondering, was I make true decision? If machine get reboot is it can be boot up safely? You can find fdisk output and fstab mount points below: Fstab: proc /proc proc defaults 0 0 none /dev/pts devpts gid=5,mode=620 0 0 /dev/md0 none swap sw 0 0 /dev/md1 /boot ext3 defaults 0 0 /dev/md2 / ext3 defaults 0 0 Fdisk: Disk /dev/sda: 750.2 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00029bb5 Device Boot Start End Blocks Id System /dev/sda1 1 262 2102562 fd Linux raid autodetect /dev/sda2 263 295 265072+ fd Linux raid autodetect /dev/sda3 296 91201 730202445 fd Linux raid autodetect Disk /dev/md0: 2152 MB, 2152923136 bytes 2 heads, 4 sectors/track, 525616 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table Disk /dev/md1: 271 MB, 271319040 bytes 2 heads, 4 sectors/track, 66240 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md1 doesn't contain a valid partition table Disk /dev/md2: 747.7 GB, 747727224832 bytes 2 heads, 4 sectors/track, 182550592 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/md2 doesn't contain a valid partition table Disk /dev/sdb: 750.2 GB, 750156374016 bytes 255 heads, 63 sectors/track, 91201 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00088969 Device Boot Start End Blocks Id System /dev/sdb1 1 262 2102562 fd Linux raid autodetect /dev/sdb2 263 295 265072+ fd Linux raid autodetect /dev/sdb3 296 91201 730202445 fd Linux raid autodetect

    Read the article

  • Virtual PC network connection setting issue

    - by George2
    Hello everyone, I am using Virtual PC 2007 on Windows Vista Enterprise x86. My confusion is about the network setting for guest OS. In the network setting, I can set the network adaptor of guest OS to one of my physical network adaptors of my host OS (I have tested that it works for guest OS to use the physical network adaptor of host OS to access external network). But in this way, 1. since both host OS and guest OS will use the same physical network adaptor, will there be any conflicts (e.g. same H/W serves two OS)? 2. will guest OS share a part of network bandwidth of the host OS of the physical network adaptor? 3. What means NAT setting in guest OS network connection adaptor? thanks in advance, George

    Read the article

  • VMWare - Writing files to virtual hard drive performance

    - by Ardman
    We have just moved our infrastructure from physical servers to virtual machines. Everything is running great and we are happy with the result of the move. We have identified one problem, and that is reading/writing performance. We have an application that compiles files and writes to disk. This is considerably slower on the new virtual machines compared to the physical machines. Is there a performance bottleneck when writing to a virtual hard drive compared to a physical hard drive?

    Read the article

  • How to use Hardware RAID in Ubuntu Server

    - by user2071938
    I have an Adaptec RAID-Controller and created an RAID-1(Mirroring) succesfully. Now I have installed Ubuntu Server 12.04.3. When I type fdisk -l I get this output: bf@fileserver:~$ sudo fdisk -l Disk /dev/sda: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/sda doesn't contain a valid partition table Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/sdb doesn't contain a valid partition table Disk /dev/sdc: 80.0 GB, 80026361856 bytes 255 heads, 63 sectors/track, 9729 cylinders, total 156301488 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0004c454 Device Boot Start End Blocks Id System /dev/sdc1 * 2048 499711 248832 83 Linux /dev/sdc2 501758 156301311 77899777 5 Extended /dev/sdc5 501760 156301311 77899776 8e Linux LVM Disk /dev/mapper/fileserver--vg-root: 75.6 GB, 75606523904 bytes 255 heads, 63 sectors/track, 9191 cylinders, total 147668992 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/fileserver--vg-root doesn't contain a valid partition table Disk /dev/mapper/ddf1_Data: 1000.1 GB, 1000065728512 bytes 255 heads, 63 sectors/track, 121584 cylinders, total 1953253376 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/mapper/ddf1_Data doesn't contain a valid partition table Disk /dev/mapper/fileserver--vg-swap_1: 4160 MB, 4160749568 bytes 255 heads, 63 sectors/track, 505 cylinders, total 8126464 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/fileserver--vg-swap_1 doesn't contain a valid partition table The 80 GB HDD is for the System The 1000.2 GB HDD should be for my data. But I'm a bit confused becauser there are listed two 1000.2 GB HDDs, due the Hardware RAID shoudln't there be only one HDD vissible to the OS? (I have two 1000.2 GB HDDs in an Raid-1 Array) dmraid gives me bf@fileserver:~$ sudo dmraid -r /dev/sdb: ddf1, ".ddf1_disks", GROUP, ok, 1953253376 sectors, data@ 0 /dev/sda: ddf1, ".ddf1_disks", GROUP, ok, 1953253376 sectors, data@ 0 so It seems to be ok? But how do I partitionate this disks and which one should I mount(sdb or sda?) Hope you can help me thx Florian

    Read the article

< Previous Page | 70 71 72 73 74 75 76 77 78 79 80 81  | Next Page >