Search Results

Search found 7455 results on 299 pages for 'power cable'.

Page 74/299 | < Previous Page | 70 71 72 73 74 75 76 77 78 79 80 81  | Next Page >

  • Will the netinstall (minimal) work with a USB cellular modem?

    - by Z9iT
    Installing Ubuntu minimal is extremely easy when the system has a LAN card and connected to internet via Cable & Router... I Recently came across a situation where I needed to install Ubuntu Minimal on a system which wash not having a LAN card and cable internet anywhere around... The only access to the internet was through a USB Plug n Play Data-Card Modem. May anyone suggest something so that I may install Ubuntu Minimal using USB Modem as the only source of Internet, if it's possible at all?? (This relates to Ubuntu 12.04 in specific)

    Read the article

  • System crashes when internet connection is unplugged

    - by Rincewind
    When i first tried to install any ubuntu newer than 10.04 on my netbook (Acer aspire one 722 11,6" WXGA - C-60 Dual Core APU - AMD Radeon HD 6250 - 1x HDMI - 2GB DDR3 - 320GB - 802.11bgN - 6CELL2.2 - BT 3.0 - VGA Webcam), it would fail to boot. I found out that the only fix to this was linking it to the internet via lan-cable during the installation. However, after installing ubuntu 12.04 successfully my system is crashing everytime i unplug the lan-cable. My first thought was disabling the netbook´s w-lan (via the band at the top) but it was not fixing the problem. Looking on the taskmanager ('top') during the process brought no further insight, no process was exploding or something like that. As i am out of guesses help would be really appreaciated. Lg Rincewind

    Read the article

  • Clarification On Write-Caching Policy, Its Underlying Options And How It Applies To Hard Drives And Solid-State Drives

    - by Boris_yo
    In last week after doing more research on subject matter, I have been wondering about what I have been neglecting all those years to understand write-caching policy, always leaving it on default setting. Write-caching policy improves writing performance and consists of write-back caching and write-cache buffer flushing. This is how I understand all the above, but correct me if I erred somewhere: Write-through cache / Write-through caching itself is not a part of write caching policy per se and it's when data is written to both cache and storage device so if Windows will need that data later again, it is retrieved from cache and not from storage device which means only improved read performance as there is no need for waiting for storage device to read required data again. Since data is still written to storage device, write performance isn't improved and represents no risk of data loss or corruption in case of power failure or system crash while only data in cache gets lost. This option seems to be enabled by default and is recommended for removable devices with no need to use function of "Safely Remove Hardware" on user's part. Write-back caching is similar to above but without writing data to storage device, periodically releasing data from cache and writing to storage device when it is idle. In my opinion this option improves both read and write performance but represents risk if power failure or system crash occurs with the outcome of not only losing data eventually to be written to storage device, but causing file inconsistencies or corrupted file system. Write-back caching cannot be enabled together with write-through caching and it is not recommended to be enabled if no backup power supply is availabe. Write-cache buffer flushing I reckon is similar to write-back caching but enables immediate release and writing of data from cache to storage device right before power outage occurs but I don't know if it applies also to occasional system crash. This option seem to be complementary to write-back cache reducing or potentially eliminating risk of data loss or corruption of file system. I have questions about relevance of last 2 options to today's modern SSDs in order to get best performance and with less wear on SSDs: I know that traditional hard drives come with onboard cache (I wonder what type of cache that is), but do SSDs also come with cache? Assuming they do, is this cache faster than their NAND flash and system RAM and worth taking the risk of utilizing it by enabling write-back cache? I read somewhere that generally storage device's cache is faster than RAM, but I want to be sure. Additionally I read that write-caching should be enabled since current data that is to be written later to NAND flash is kept for a while in cache and provided there is data that gets modified a lot before finally being written, holding of this data and its periodic release reduces its write times to SSD thereby reducing its wearing. Now regarding to write-cache buffer flushing, I heard that SSD controllers are so fast by themselves that enabling this option is not required, because they manage flushing. However, once again, I don't know if SSDs have their own onboard cache and whether or not it is faster than their NAND flash and system RAM because if it is, keeping this option enabled would make sense. Recently I have posted question about issue with my Intel 330 SSD 120GB which was main reason to do deeper research having suspicion of write-caching policy being the culprit of SSD's freezing issue assuming data being released is what causes freezes. Currently I have write-cache enabled and write-cache buffer flushing disabled because I believe SSD controller's management of write-cache flushing and Windows write-cache buffer flushing are conflicting with each other: Since I want to troubleshoot in small steps to finally determine the source of issue, I have decided to start with write-caching policy and the move to drivers, switching to AHCI later on and finally disabling DIPM (device initiated power management) through registry modification thanks to @TomWijsman

    Read the article

  • Getting wireless to work on Ubuntu 11.10 (on a mac machine)

    - by yayu
    I have a 2008 white 13.3 inch macbook that now solely runs ubuntu. However, I cannot get wifi or cable to work on it. Regarding the cable, it atleast tries to connect but eventually disconnects from the wired network. Here is the output for lspci (pastebin) I tried installing b43-fwcutter and firmware-b43 but get errors. (I loaded them from a thumb drive and tried sudo dpkg -i). I cannot understand these instructions from the documentation, as I cannot locate the pool directory. b43-fwcutter is located on the Ubuntu install media under ../pool/main/b/b43-fwcutter/ and patch is located under ../pool/main/p/patch/ or both in the official repositories online. Note: In some versions (10.04 and 11.04 at least) there is not a /pool/main/p/patch/ If this file is missing then you don't need it. In this case you only need to install /pool/main/b/b43-fwcutter by following the instructions below.

    Read the article

  • Black frame around screen after HDMI connection failure

    - by Wolter Hellmund
    I was trying to watch a movie in my computer through the TV, so I connected both with an HDMI cable. I was unable to have a successful setup (the colors were all weird on the TV and the screen size, incorrect), I tried many resolutions using the nvidia-settings application and somehow my screen got framed by a black border and after that I have been unable to remove it, even after restarting the computer and not being connected to the HDMI cable anymore. I am using Ubuntu 11.10 amd64, my GPU is an nVidia GeForce 8600M GT and I am using the propietary driver version 280. The problem is due to some setting with my account only. I logged in to the guest session and the resolution is right there. Also, my desktop "thinks" the resolution is right (i.e. 1280x800), but it must be right in another scale because there is pixel area occupied by the black frame.

    Read the article

  • Ubuntu 12.04 wired ethernet not working and wireless not working, How do I fix it?

    - by Eloy
    I am new to ubuntu. I recently installed the latest ubuntu for desktop from http://www.ubuntu.com/download. I was very excited to start using ubuntu until I booted the computer and saw that i couldn't connect to the internet at all. I have spent hours trying to figure this out. I keep running into people suggesting installing drivers etc. I have tried about everything and nothing seems to work. I have the ethernet cable connected to the computer but it doesn't recognize it. I ran the following: lspci | grep -i eth and I get this 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5752 Gigabit Ethernet PCI Express (rev 02) Any help would be much appreciated. I am kind of bummed I have spent all this time tyring to get the internet to work and haven't even gotten to use the power of ubuntu Update copied from comment: Changing the Ethernet cable to a different one fixed the problem.

    Read the article

  • Linear regression confidence intervals in SQL

    - by Matt Howells
    I'm using some fairly straight-forward SQL code to calculate the coefficients of regression (intercept and slope) of some (x,y) data points, using least-squares. This gives me a nice best-fit line through the data. However we would like to be able to see the 95% and 5% confidence intervals for the line of best-fit (the curves below). What these mean is that the true line has 95% probability of being below the upper curve and 95% probability of being above the lower curve. How can I calculate these curves? I have already read wikipedia etc. and done some googling but I haven't found understandable mathematical equations to be able to calculate this. Edit: here is the essence of what I have right now. --sample data create table #lr (x real not null, y real not null) insert into #lr values (0,1) insert into #lr values (4,9) insert into #lr values (2,5) insert into #lr values (3,7) declare @slope real declare @intercept real --calculate slope and intercept select @slope = ((count(*) * sum(x*y)) - (sum(x)*sum(y)))/ ((count(*) * sum(Power(x,2)))-Power(Sum(x),2)), @intercept = avg(y) - ((count(*) * sum(x*y)) - (sum(x)*sum(y)))/ ((count(*) * sum(Power(x,2)))-Power(Sum(x),2)) * avg(x) from #lr Thank you in advance.

    Read the article

  • SharePoint – The Most Important Feature

    - by Bil Simser
    Watching twitter and doing a search for SharePoint and you see a lot (almost one every few minutes) of tweets about the top 10 new features in SharePoint. What answer do you get when you ask the question, “What’s the most important feature in SharePoint?”. Chances are the answer will vary. Some will say it’s the collaboration aspect, others might say it’s the new ribbon interface, multi-item editing, external content types, faceted search, large list support, document versioning, Silverlight, etc. The list goes on. However I think most people might be missing the most important feature that’s sitting right under their noses all this time. The most important feature of SharePoint? It’s called User Empowerment. Huh? What? Is that something I find in the Site Actions menu? Nope. It’s something that’s always been there in SharePoint, you just need to get the word out and support it. How many times have you had a team ask you for a team site (assuming you had SharePoint up and running). Or to create them a contact list. Or how long have you employed that guy in the corner who’s been copying and pasting content from Corporate Communications into the web from a Word document. Let’s stop the insanity. It doesn’t have to be this way. SharePoint’s strongest feature isn’t anything you can find in the Site Settings screen or Central Admin. It’s all about empowering your users and letting them take control of their content. After all, SharePoint really is a bunch of tools to allow users to collaborate on content isn’t it? So why are you stepping in as IT and helping the user every moment along the way. It’s like having to ask users to fill out a help desk ticket or call up the Windows team to create a folder on their desktop or rearrange their Start menu. This isn’t something IT should be spending their time doing nor is it something the users should be burdened with having to wait until their friendly neighborhood tech-guy (or gal) shows up to help them sort the icons on their desktop. SharePoint IS all about empowerment. Site owners can create whatever lists and libraries they need for their team, and if the template isn’t there they can always turn to my friend and yours, the Custom List. From that can spew forth approval tracking systems, new hire checklists, and server inventory. You’re only limited by your imagination and needs. Users should be able to create new sites as they need. Want a blog to let everyone know what your team is up to? Go create one, here’s how. What’s a blog you ask? Here’s what it is and why you would use one. SharePoint is the shift in the balance of power and you need, and an IT group, let go of certain responsibilities and let your users run with the tools. A power user who knows how to create sites and what features are available to them can help a team go from the forming stage to the storming stage overnight. Again, this all hinges on you as an IT organization and what you can and empower your users with as far as features go. Running with tools is great if you know how to use them, running with scissors not recommended unless you enjoy trips to the hospital. With Great Power comes Great Responsibility so don’t go out on Monday and send out a memo to the organization saying “This Bil guy says you peeps can do anything so here it is, knock yourself out” (for one, they’ll have *no* idea who this Bil guy is). This advice comes with the task of getting your users ready for empowerment. Whether it’s through some kind of internal training sessions, in-house documentation; videos; blog posts; on how to accomplish things in SharePoint, or full blown one-on-one sit downs with teams or individuals to help them through their problems. The work is up to you. Helping them along also should be part of your governance (you do have one don’t you?). Just because you have InfoPath client deployed with your Office suite, doesn’t mean users should just start publishing forms all over your SharePoint farm. There should be some governance behind that in what you’ll support and what is possible. The other caveat to all this is that SharePoint is not everything for everyone. It can’t cook you breakfast and impregnate your cat or solve world hunger. It also isn’t suited for every IT solution out there. It’s a horrible source control system (even though some people try to use it as such) and really can’t do financials worth a darn. Again, governance is key here and part of that governance and your responsibility in setting up and unleashing SharePoint into your organization is to provide users guidance on what should be in SharePoint and (more importantly) what should not be in SharePoint. There are boundaries you have to set where you don’t want your end users going as they might be treading into trouble. Again, this is up to you to set these constraints and help users understand why these pylons are there. If someone understands why they can’t do something they might have a better understanding and respect for those that put them there in the first place. Of course you’ll always have the power-users who want to go skiing down dead mans curve so this doesn’t work for everyone, but you can catch the majority of the newbs who don’t wander aimlessly off the beaten path. At the end of the day when all things are going swimmingly your end users should be empowered to solve the needs they have on a day to day basis and not having to keep bugging the IT department to help them create a view to show only approved documents. I wouldn’t go as far as business users building out full blown solutions and handing the keys to SharePoint Designer or (worse) Visual Studio to power-users might not be a path you want to go down but you also don’t have to lock up the SharePoint system in a tight box where users can’t use what’s there. So stop focusing on the shiny things in SharePoint and maybe consider making a shift to what’s really important. Making your day job easier and letting users get the most our of your technology investment.

    Read the article

  • Thread placement policies on NUMA systems - update

    - by Dave
    In a prior blog entry I noted that Solaris used a "maximum dispersal" placement policy to assign nascent threads to their initial processors. The general idea is that threads should be placed as far away from each other as possible in the resource topology in order to reduce resource contention between concurrently running threads. This policy assumes that resource contention -- pipelines, memory channel contention, destructive interference in the shared caches, etc -- will likely outweigh (a) any potential communication benefits we might achieve by packing our threads more densely onto a subset of the NUMA nodes, and (b) benefits of NUMA affinity between memory allocated by one thread and accessed by other threads. We want our threads spread widely over the system and not packed together. Conceptually, when placing a new thread, the kernel picks the least loaded node NUMA node (the node with lowest aggregate load average), and then the least loaded core on that node, etc. Furthermore, the kernel places threads onto resources -- sockets, cores, pipelines, etc -- without regard to the thread's process membership. That is, initial placement is process-agnostic. Keep reading, though. This description is incorrect. On Solaris 10 on a SPARC T5440 with 4 x T2+ NUMA nodes, if the system is otherwise unloaded and we launch a process that creates 20 compute-bound concurrent threads, then typically we'll see a perfect balance with 5 threads on each node. We see similar behavior on an 8-node x86 x4800 system, where each node has 8 cores and each core is 2-way hyperthreaded. So far so good; this behavior seems in agreement with the policy I described in the 1st paragraph. I recently tried the same experiment on a 4-node T4-4 running Solaris 11. Both the T5440 and T4-4 are 4-node systems that expose 256 logical thread contexts. To my surprise, all 20 threads were placed onto just one NUMA node while the other 3 nodes remained completely idle. I checked the usual suspects such as processor sets inadvertently left around by colleagues, processors left offline, and power management policies, but the system was configured normally. I then launched multiple concurrent instances of the process, and, interestingly, all the threads from the 1st process landed on one node, all the threads from the 2nd process landed on another node, and so on. This happened even if I interleaved thread creating between the processes, so I was relatively sure the effect didn't related to thread creation time, but rather that placement was a function of process membership. I this point I consulted the Solaris sources and talked with folks in the Solaris group. The new Solaris 11 behavior is intentional. The kernel is no longer using a simple maximum dispersal policy, and thread placement is process membership-aware. Now, even if other nodes are completely unloaded, the kernel will still try to pack new threads onto the home lgroup (socket) of the primordial thread until the load average of that node reaches 50%, after which it will pick the next least loaded node as the process's new favorite node for placement. On the T4-4 we have 64 logical thread contexts (strands) per socket (lgroup), so if we launch 48 concurrent threads we will find 32 placed on one node and 16 on some other node. If we launch 64 threads we'll find 32 and 32. That means we can end up with our threads clustered on a small subset of the nodes in a way that's quite different that what we've seen on Solaris 10. So we have a policy that allows process-aware packing but reverts to spreading threads onto other nodes if a node becomes too saturated. It turns out this policy was enabled in Solaris 10, but certain bugs suppressed the mixed packing/spreading behavior. There are configuration variables in /etc/system that allow us to dial the affinity between nascent threads and their primordial thread up and down: see lgrp_expand_proc_thresh, specifically. In the OpenSolaris source code the key routine is mpo_update_tunables(). This method reads the /etc/system variables and sets up some global variables that will subsequently be used by the dispatcher, which calls lgrp_choose() in lgrp.c to place nascent threads. Lgrp_expand_proc_thresh controls how loaded an lgroup must be before we'll consider homing a process's threads to another lgroup. Tune this value lower to have it spread your process's threads out more. To recap, the 'new' policy is as follows. Threads from the same process are packed onto a subset of the strands of a socket (50% for T-series). Once that socket reaches the 50% threshold the kernel then picks another preferred socket for that process. Threads from unrelated processes are spread across sockets. More precisely, different processes may have different preferred sockets (lgroups). Beware that I've simplified and elided details for the purposes of explication. The truth is in the code. Remarks: It's worth noting that initial thread placement is just that. If there's a gross imbalance between the load on different nodes then the kernel will migrate threads to achieve a better and more even distribution over the set of available nodes. Once a thread runs and gains some affinity for a node, however, it becomes "stickier" under the assumption that the thread has residual cache residency on that node, and that memory allocated by that thread resides on that node given the default "first-touch" page-level NUMA allocation policy. Exactly how the various policies interact and which have precedence under what circumstances could the topic of a future blog entry. The scheduler is work-conserving. The x4800 mentioned above is an interesting system. Each of the 8 sockets houses an Intel 7500-series processor. Each processor has 3 coherent QPI links and the system is arranged as a glueless 8-socket twisted ladder "mobius" topology. Nodes are either 1 or 2 hops distant over the QPI links. As an aside the mapping of logical CPUIDs to physical resources is rather interesting on Solaris/x4800. On SPARC/Solaris the CPUID layout is strictly geographic, with the highest order bits identifying the socket, the next lower bits identifying the core within that socket, following by the pipeline (if present) and finally the logical thread context ("strand") on the core. But on Solaris on the x4800 the CPUID layout is as follows. [6:6] identifies the hyperthread on a core; bits [5:3] identify the socket, or package in Intel terminology; bits [2:0] identify the core within a socket. Such low-level details should be of interest only if you're binding threads -- a bad idea, the kernel typically handles placement best -- or if you're writing NUMA-aware code that's aware of the ambient placement and makes decisions accordingly. Solaris introduced the so-called critical-threads mechanism, which is expressed by putting a thread into the FX scheduling class at priority 60. The critical-threads mechanism applies to placement on cores, not on sockets, however. That is, it's an intra-socket policy, not an inter-socket policy. Solaris 11 introduces the Power Aware Dispatcher (PAD) which packs threads instead of spreading them out in an attempt to be able to keep sockets or cores at lower power levels. Maximum dispersal may be good for performance but is anathema to power management. PAD is off by default, but power management polices constitute yet another confounding factor with respect to scheduling and dispatching. If your threads communicate heavily -- one thread reads cache lines last written by some other thread -- then the new dense packing policy may improve performance by reducing traffic on the coherent interconnect. On the other hand if your threads in your process communicate rarely, then it's possible the new packing policy might result on contention on shared computing resources. Unfortunately there's no simple litmus test that says whether packing or spreading is optimal in a given situation. The answer varies by system load, application, number of threads, and platform hardware characteristics. Currently we don't have the necessary tools and sensoria to decide at runtime, so we're reduced to an empirical approach where we run trials and try to decide on a placement policy. The situation is quite frustrating. Relatedly, it's often hard to determine just the right level of concurrency to optimize throughput. (Understanding constructive vs destructive interference in the shared caches would be a good start. We could augment the lines with a small tag field indicating which strand last installed or accessed a line. Given that, we could augment the CPU with performance counters for misses where a thread evicts a line it installed vs misses where a thread displaces a line installed by some other thread.)

    Read the article

  • Oracle Expands Sun Blade Portfolio for Cloud and Highly Virtualized Environments

    - by Ferhat Hatay
    Oracle announced the expansion of Sun Blade Portfolio for cloud and highly virtualized environments that deliver powerful performance and simplified management as tightly integrated systems.  Along with the SPARC T3-1B blade server, Oracle VM blade cluster reference configuration and Oracle's optimized solution for Oracle WebLogic Suite, Oracle introduced the dual-node Sun Blade X6275 M2 server module with some impressive benchmark results.   Benchmarks on the Sun Blade X6275 M2 server module demonstrate the outstanding performance characteristics critical for running varied commercial applications used in cloud and highly virtualized environments.  These include best-in-class SPEC CPU2006 results with the Intel Xeon processor 5600 series, six Fluent world records and 1.8 times the price-performance of the IBM Power 755 running NAMD, a prominent bio-informatics workload.   Benchmarks for Sun Blade X6275 M2 server module  SPEC CPU2006  The Sun Blade X6275 M2 server module demonstrated best in class SPECint_rate2006 results for all published results using the Intel Xeon processor 5600 series, with a result of 679.  This result is 97% better than the HP BL460c G7 blade, 80% better than the IBM HS22V blade, and 79% better than the Dell M710 blade.  This result demonstrates the density advantage of the new Oracle's server module for space-constrained data centers.     Sun Blade X6275M2 (2 Nodes, Intel Xeon X5670 2.93GHz) - 679 SPECint_rate2006; HP ProLiant BL460c G7 (2.93 GHz, Intel Xeon X5670) - 347 SPECint_rate2006; IBM BladeCenter HS22V (Intel Xeon X5680)  - 377 SPECint_rate2006; Dell PowerEdge M710 (Intel Xeon X5680, 3.33 GHz) - 380 SPECint_rate2006.  SPEC, SPECint, SPECfp reg tm of Standard Performance Evaluation Corporation. Results from www.spec.org as of 11/24/2010 and this report.    For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   Fluent The Sun Fire X6275 M2 server module produced world-record results on each of the six standard cases in the current "FLUENT 12" benchmark test suite at 8-, 12-, 24-, 32-, 64- and 96-core configurations. These results beat the most recent QLogic score with IBM DX 360 M series platforms and QLogic "Truescale" interconnects.  Results on sedan_4m test case on the Sun Blade X6275 M2 server module are 23% better than the HP C7000 system, and 20% better than the IBM DX 360 M2; Dell has not posted a result for this test case.  Results can be found at the FLUENT website.   ANSYS's FLUENT software solves fluid flow problems, and is based on a numerical technique called computational fluid dynamics (CFD), which is used in the automotive, aerospace, and consumer products industries. The FLUENT 12 benchmark test suite consists of seven models that are well suited for multi-node clustered environments and representative of modern engineering CFD clusters. Vendors benchmark their systems with the principal objective of providing comparative performance information for FLUENT software that, among other things, depends on compilers, optimization, interconnect, and the performance characteristics of the hardware.   FLUENT application performance is representative of other commercial applications that require memory and CPU resources to be available in a scalable cluster-ready format.  FLUENT benchmark has six conventional test cases (eddy_417k, turbo_500k, aircraft_2m, sedan_4m, truck_14m, truck_poly_14m) at various core counts.   All information on the FLUENT website (http://www.fluent.com) is Copyrighted1995-2010 by ANSYS Inc. Results as of November 24, 2010. For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   NAMD Results on the Sun Blade X6275 M2 server module running NAMD (a parallel molecular dynamics code designed for high-performance simulation of large biomolecular systems) show up to a 1.8X better price/performance than IBM's Power 7-based system.  For space-constrained environments, the ultra-dense Sun Blade X6275 M2 server module provides a 1.7X better price/performance per rack unit than IBM's system.     IBM Power 755 4-way Cluster (16U). Total price for cluster: $324,212. See IBM United States Hardware Announcement 110-008, dated February 9, 2010, pp. 4, 21 and 39-46.  Sun Blade X6275 M2 8-Blade Cluster (10U). Total price for cluster:  $193,939. Price/performance and performance/RU comparisons based on f1ATPase molecule test results. Sun Blade X6275 M2 cluster: $3,568/step/sec, 5.435 step/sec/RU. IBM Power 755 cluster: $6,355/step/sec, 3.189 step/sec/U. See http://www-03.ibm.com/systems/power/hardware/reports/system_perf.html. See http://www.ks.uiuc.edu/Research/namd/performance.html for more information, results as of 11/24/10.   For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   Reverse Time Migration The Reverse Time Migration is heavily used in geophysical imaging and modeling for Oil & Gas Exploration.  The Sun Blade X6275 M2 server module showed up to a 40% performance improvement over the previous generation server module with super-linear scalability to 16 nodes for the 9-Point Stencil used in this Reverse Time Migration computational kernel.  The balanced combination of Oracle's Sun Storage 7410 system with the Sun Blade X6275 M2 server module cluster showed linear scalability for the total application throughput, including the I/O and MPI communication, to produce a final 3-D seismic depth imaged cube for interpretation. The final image write time from the Sun Blade X6275 M2 server module nodes to Oracle's Sun Storage 7410 system achieved 10GbE line speed of 1.25 GBytes/second or better performance. Between subsequent runs, the effects of I/O buffer caching on the Sun Blade X6275 M2 server module nodes and write optimized caching on the Sun Storage 7410 system gave up to 1.8 GBytes/second effective write performance. The performance results and characterization of this Reverse Time Migration benchmark could serve as a useful measure for many other I/O intensive commercial applications. 3D VTI Reverse Time Migration Seismic Depth Imaging, see http://blogs.sun.com/BestPerf/entry/3d_vti_reverse_time_migration for more information, results as of 11/14/2010.                            

    Read the article

  • WinXP: Error 1167 -- Device (LPT1) not connected

    - by Thomas Matthews
    I am writing a program that opens LPT1 and writes a value to it. The WriteFile function is returning an error code of 1167, "The device is not connected". The Device Manager shows that LPT1 is present. I have a cable connected between a development board and the PC. The cable converts JTAG pin signals to signals on the parallel port. Power is applied and the cable is connected between the development board and the PC. The development board is powered on. I am using: Windows XP MS Visual Studio 2008, C language, console application, debug environment. Here is the relevant code fragments: HANDLE parallel_port_handle; void initializePort(void) { TCHAR * port_name = TEXT("LPT1:"); parallel_port_handle = CreateFile( port_name, GENERIC_READ | GENERIC_WRITE, 0, // must be opened with exclusive-access NULL, // default security attributes OPEN_EXISTING, // must use OPEN_EXISTING 0, // not overlapped I/O NULL // hTemplate must be NULL for comm devices ); if (parallel_port_handle == INVALID_HANDLE_VALUE) { // Handle the error. printf ("CreateFile failed with error %d.\n", GetLastError()); Pause(); exit(1); } return; } void writePort( unsigned char a_ucPins, unsigned char a_ucValue ) { DWORD dwResult; if ( a_ucValue ) { g_siIspPins = (unsigned char) (a_ucPins | g_siIspPins); } else { g_siIspPins = (unsigned char) (~a_ucPins & g_siIspPins); } /* This is a sample code for Windows/DOS without Windows Driver. */ // _outp( g_usOutPort, g_siIspPins ); //---------------------------------------------------------------------- // For Windows XP and later //---------------------------------------------------------------------- if(!WriteFile (parallel_port_handle, &g_siIspPins, 1, &dwResult, NULL)) { printf("Could not write to LPT1 (error %d)\n", GetLastError()); Pause(); return; } } If you believe this should be posted on Stack Overflow, please migrate it over (thanks).

    Read the article

  • Problem with switch dell 6224

    - by Matias
    Hello, we just have upgraded the firmware of a dell 6224 power connect switch and it won't reload. These are the symptons: - I power up the switch having the serial cable connected to it and the switch outputs nothing. The configuration of the serial console is fine: 9600 bds, etc... In fact, before the upgrade, I was connected to the switch through the very same cable. - Reseting the switch with its reset pinhole does not reset the switch: the power and fan lights powers off while I keep pressed the pinhole, but the switch itself does not resets. - When I connect an UTP cable to one of the switches port, the green lights don't flash, but ''mii-tool eth0'' in my laptop shows there is link!! The only thing I see in the output, different from other upgrades I've done, is this line at the end: Erasing Boot Flash.....^^^^Done. Any help or idea will be more than welcome!! Thanks!! console#show version Image Descriptions image1 : image2 : Images currently available on Flash -------------------------------------------------------------------- unit image1 image2 current-active next-active 1 <none> 3.0.0.8 image2 image2 console#boot system image2 Activating image image2 .. console#update bootcode Update bootcode and reset (Y/N)? Updating boot code ... Extracting boot code from image... Erasing Boot Flash.....^^^^Done.

    Read the article

  • What device can create wireless network while connecting to an ethernet router

    - by Nicolo
    Hi, I have access to an ethernet port of a wireless router. I simply connect my laptop to it via an ethernet cable. There are a total of four such ports on the wireless router. Now I want to connect a device (a wireless access point? wireless bridge? wireless switch?) via an ethernet cable to one of the other ethernet ports of the router. I want this device to act as a kind of wireless switch - it should "split" the ethernet connection coming from the router to two or more computers that connect to this device via a wireless. Basically, I have a wireless router with its wireless function switched off. I don't know the password for that router so can't activate the wireless function. Don't know the password of the ISP either. The only thing I can do is to connect via ethernet cable to the wireless router and this does not require a password. Now I want to use that connection and build a wireless upon it. What kind of device do I need? I am not really very well informed about network management and find the descriptions "wireless access point", "wireless bridge", "wireless switch" confusing. I know what an ethernet switch is - what I need is a device which would do the same but by allowing the clients to connect to it via a wireless. What kind of device would do that? Any recommendations about specific products?

    Read the article

  • big speed difference on a network link with and without VPN tunnel

    - by xirtyllo
    Scenario: We have a network link between two offices. The link is provided by a third party company through a VLAN on their network, but to us it is totally transparent -as if we had a simple ethernet cable going from one location to the other-. We have one router at each side of the link, with 3 VPN tunnels in between the two. The test: When I test the speed of the network link with the routers in place, with one laptop directly connected to the router on each side, I consistently get ~30/35Mbps. But if I take out the routers and I test the link connecting the laptops directly to the ethernet cable at each side, I consistently get ~85/88Mbps. It's quite a big performance hit, and I would tend to think that the VPN tunnels are responsible for the slow down. Is it normal that this configuration (two routers with three VPN tunnels between them) takes away so much bandwidth? More info: The encryption algorithm used for the VPN tunnels is AES128. The routers model is Zyxel USG200 and Zyxel USG1000, and their CPU, memory, and storage use is well within normal limits. The nominal bandwidth of the network link is 100Mbps. The network link in question is supplied by a third party company (the building in between our two offices). Basically it passes through their network as a VLAN, but the VLAN is completely transparent to us (e.g. no configuration required on our side, just like one single cable from end to end). Unfortunately (or maybe fortunately) I cannot directly test different routers configurations as I'm not the person in charge of it.

    Read the article

  • Can I make two wireless routers communicate using the wireless?

    - by Dana Robinson
    I want to make a setup like this: cable modem <-cable- wireless router 1 <-wireless- wireless router 2 in another room <-cables- PCs in another room Basically, I want to extend my network access across the house and then have a bunch of network jacks available for my office PCs. Right now, I have a cable modem going to a wireless router in one room and a PC with a wireless PCI card in it in the office on the other side of the house. I use internet connection sharing with the other PCs in the office. The problem is that ICS is flaky, especially when I switch to VPN on the Windows box to access files at work. I picked up a wireless USB adapter that I thought I could share among the PCs I work on but I'm not very happy with it so I'm going to return it (NDISwrapper support for it is poor). Is this possible? My wireless experience so far has been pretty straightforward so I have no idea what kind of hardware is available. I've looked at network extenders but those just look like repeaters for signal strength. I want wired network jacks in my office.

    Read the article

  • Wireless router blocking some sites while using ethernet is fine

    - by Micke
    I'm using Windows 7 and my router is a wireless Apple Airport Express that is approximately two years old. Suddenly I can't access some sites (for example www.sthlm.friskissvettis.se, or www.vegetarian-shoes.co.uk, some streamed tv-shows on svtplay.se, and a number of other random sites) when connecting to internet with my router. It worked good until recently and I'm fairly sure this problem emerged when my ISP upgraded from 10/10mbit to 100/10mbit speed. Most other sites like facebook and google works fine. When using my network cable to connect to internet everything works fine and I can access these sites. Firmware is current and I've tried reseting the router to factory defaults. Tried different browsers, and I can't ping the "blocked" sites either. Tracert www.sthlm.friskissvettis.se starts with 10.0.0.1 and continues through a number of long addresses until it says timeout. The last working address before timeout was sth-tcy-ipcore01-ge-0-2-0.neq.dgcsystems.net [83.241.252.13], if it matters. Tracert www.vegetarian-shoes.co.uk also eventually gives me a timeout. When the network cable is plugged in, I still get timeout on tracert www.sthlm.friskissvettis.se even though I can access the site in Chrome. Weird. www.vegetarian-shoes.co.uk doesn't give me a tracert timeout when the cable is plugged in, and I can access the site as usual. I've tried changing DNS servers to use opendns servers instead, but to no use. I've tried pinging these two sites with a lower MTU packet size (with this method: http://www.richard-slater.co.uk/archives/2009/10/23/change-your-mtu-under-vista-or-windows-7/), but still can't access them through ping... I don't know what to do anymore.... any suggestions???

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • How to connect 2 routers (Asmax and D-link) RJ11 vs RJ45 issue

    - by piobyz
    I just bought a new router, D-link DSL 2641B and want to connect it to another one, provided by my ISP, Asmax AR 804MP. Previously, I had Linksys WRT350N, and there was no problem, while I had Ethernet cable plugged in to one of LAN ports in Asmax and INTERNET(RJ45) port in Linksys, connection used PPPoE protocol -- worked OK. D-link has DSL(RJ11) port (which I don't want to use as Asmax replacement, while there is a separate Ethernet cable with a TV plugged to Asmax, which I don't want to configure from scratch on D-link). How should I connect my new D-link to work with Asmax? Via DSL port? Via one of the LAN ports (in which case I probably should change the purpose of this port in the config, I guess?). I tried connecting D-link both ways: LAN(ASMAX) to LAN(DLINK) LAN(ASMAX) to DSL(DLINK) (using RJ11 - RJ45 cable) I hope there is some setting in the DLINK's config that I overlooked. I haven't tried to see what's in ASMAX's config, but I guess I don't need to change anything there, while Linksys worked just fine? The only difference I see, is that D-link has RJ11 DSL port as WAN, and Linksys has RJ45 (called by them INTERNET) as a main WAN port.

    Read the article

  • ATI HDMI Audio disappears in Windows 7 when a TV is connected

    - by jsalonen
    So far I have unsuccessfully googled for HOURS with no luck fixing this very annoying problem. The settings is the following: I have PC running Windows 7 RC (64-bit) Video card is a ATI Radeon 4850 series card (Sapphire HD 4850 512MB to be exact) The video card has HDMI out with built-in audio chip I have an HDMI cable connecting the PC to a TV (Sony Bravia series) The problem is that when I connect the HDMI cable to the TV, the ATI HDMI Sound output device disappears completely from the list of playback devices in Windows. As a workaround I can restore the audio by re-installing the HDMI audio driver. However, when I disconnect the TV the driver disappears again. So basically, every time I want to watch stuff on my TV, I have to reinstall audio driver, which of course is VERY annoying. EDIT: I have figured out that I do not need to re-istall the HDMI audio driver to restore sound; I only need to reboot my computer with the HDMI cable plugged in to restore the audio driver. This suggests that the problem has something to do with information passed from TV to computer, which makes my HDMI Audio driver disappear. Are there any other, more elegant workarounds for this problem? All help is much appreciated!

    Read the article

  • Slow File Copy observed copying 40GB files across network to iSCSI device

    - by Rick
    Here's a curious ones for the gurus: Setup: Source Machine: Windows Server 2003 R2 machine with local hard drive. VHD file of 40GB. 1 x 1Gbps network card, Cat6 cable, switch. Target Machine: Windows Server 2008 R2 machine with iSCSI connection to iSCSI target on separate machine (1TB, RAID5). 1 x 1Gbps network card, Cat6 cable, connected to same switch as for Source Machine. Second 1Gbps network card, Cat6 cable, connected via isolated switch to the iSCSI target. Switches are Netgear JGS524 model (web managed). If I copy from the Win2003R2 machine to Win2008R2 machine local drive I get 40GB in 45 minutes, 36 seconds. If I copy from the Win2008R2 machine to the iSCSI target (local drive to iSCSI target) I get 40GB in 37 minutes 56 seconds. If I copy from the Win2003R2 machine to the iSCSI target via the Win2008R2 machine I get 40GB in 3 hours, 50 minutes, 24 seconds. All copies were done via the following command issued on the Win2008R2 box: XCOPY <source> <target> /J XCOPY /J - Copies using unbuffered I/O. Recommended for very large files. So, what's the bit I'm missing here? Why does a back-to-back copy take in total 1 hour, 23 minutes, 32 seconds when a "straight through" copy take almost 3 times as long? Switches show no errors, network hovers around the 3% utilisation mark for the duration of the copy (whereas the "back-to-back" copies are around the 25% utilisation mark). What have I missed?

    Read the article

  • Internet Connection not working - USB LAN connection - from particular modem

    - by Paul
    I am trying to fix Internet connection on a friends Dell inspiron 1720 with XP service pack 3. It has an integrated network card that stopped working, after powering down/up the modem still didnt work I brought it back to my place to try a few things ie check cable, update driver etc... still didnt work. So I bought a USB LAN connector. It didnt work straight away but I went to configure the properties and changed the ConnectionType from AutoSense to 100 BaseT 10BaseT Full_Duplex, I basically just tried them all. From my place when connected to my desktop - 10 BaseT and 10BaseT Full_Duplex worked. From my place When connected to their laptop - 10 BaseT and 10BaseT Full_Duplex worked. Happy I went back to my friends house confident it would all work, and it didnt. Brought it back to mine and it did. While there, in Network Connections the connection is there recognized, enabled, 'working properly' it just says not connected. Also there is no led on the USB connector While at mine as above except there is an led on the USB connector and it says connected. Other difference I can think of is they have a cable modem, I'm plugged into the back of a Belkin wireless router - would this make a difference? Any other ideas what to try? (Would getting the model of the cable modem help anyone?) The USB connector is "DM9601 USB to Fast Ethernet"

    Read the article

  • Can I get ethernet out of my Verizon FIOS set-top box?

    - by Tom Hughes
    Setup: my home network is long & skinny, and the FIOS-connected router is all the way at one of the apartment. At the other end, far away (and a floor higher) is my HD TV, which gets a cable-TV signal from a Verizon set-top box that is coax-connected back to the FIOS on-premises equipment. Wi-Fi won't work, the apartment is too stretched out, with old, thick walls and floors. Goal: I think there are three ways to get ethernet back to where the HD TV is: 1) run a cable! this isn't crazy but isn't cheap either (my building won't let me do it, it involves hiring an electrician because the cable would run partly through the public hallway ceiling) 2) split the coax near the TV and put in... a MoCA device? 3) somehow tease the set-top box, which has an RJ-11 (ethernet) port on the back, to give me network access. Question: any other choices? and, is one choice better than the others? #3 is by far the most desirable because it would involve the least wiring -- but I can't find any resources to help make it happen. #2 is a bit scary, I don't want to degrade service to the TV or anywhere else for that matter.

    Read the article

  • server and user directly connected no pinging...

    - by jtzero
    I have a server(fedora 12) with two nics on it, directly connected to say 192.168.1.0 and 192.168.2.0 the route table looks like this Destination Gateway Genmask Flags Metric Ref Use Iface 192.168.1.0 192.168.1.1 255.255.255.0 U 0 0 0 eth0 192.168.2.0 * 255.255.255.0 U 0 0 0 eth1 eth0 = 192.168.1.15 eth1 = 192.168.2.1 and a directly connected user (Mythdora) on the 192.168.2.0 network with ip 192.168.2.2 and route table like so Destination Gateway Genmask Flags Metric Ref Use Iface 192.168.2.0 * 255.255.255.0 U 0 0 0 eth0 the cable is a crossover and it works all three nics work -- connected my laptop to either end and assign it a valid 192.168.2.0 ip the pings will work. In fact if I disconnect the server side and plug the eth cable into the laptop and have thte box ping the laptop continually remove the eth cable and plug it back into the server both sides ping... unfortunately the box realizing it's connected to a different pc wipes its route table after say ten minutes or so. if I do a trace route from a box on the 1.0 network to the servers 192.168.2.1 interface never get a reply from it. as a note at one point I could ping the server from the 192.168.2.2 box but the server couldnt ping the 192.168.2.2 box.

    Read the article

  • How to Load Balance 2 Internet Connections on a Windows 7 machine?

    - by Jimmy Chandra
    It's sort of related to this particular question, but that one is on Mac. I am looking for similar solution on Windows 7. I have 2 network connections: (Connection A) Wireless terminal connecting to ISP A (3G / EVDO internet provider) (Connection B) Broadband wired connection connecting to ISP B (Cable internet provider) Both has access to the internet. When I try connecting to a website and checking the networking tab on my Task Manager, I only see the network traffic being routed to only Connection A. Is there a way to make the computer to utilize both network (in a sense using all the bandwidth available from both the Cable ISP and the 3G / EVDO ISP) at the same time? If so, what do I need to do to set this up ... on Windows 7? Here is a bit more info on my network connections (ipconfig /all): PPP adapter Wireless Terminal: IPv4: aa.bb.ccc.ddd(preferred) Subnet mask: 255.255.255.255 Default Gateway: 0.0.0.0 DNS: aa.ee.f.ggg aa.ee.f.hhh Primary Wins: jjj.ii.k.l Secondary Wins: jjj.ii.k.m Ethernet adapter LAN: IPv4: 192.168.1.100 (connected to a router by wired that itself connect to a cable modem) subnet mask: 255.255.255.0 Default gateway: 192.168.1.1 (the wireless router) DHCP: 192.168.1.1 (the wireless router) DNS: xxx.yy.zz.ww rr.sss.t.uuu For my own privacy, I don't believe the actual number matters, the patterns are representative of the ip numbering scheme...

    Read the article

< Previous Page | 70 71 72 73 74 75 76 77 78 79 80 81  | Next Page >