Search Results

Search found 2523 results on 101 pages for 'communication'.

Page 75/101 | < Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >

  • Apache + mod_fcgid + perl = error 500

    - by f-aminov
    Hi guys! I'm trying to setup Apache2.2 with mod_fcgid and libapache2-mod-perl2 with no luck. I've created a fcgi-bin directory in the root directory of my website and put there a test.fcgi file with the following content: #!/usr/bin/perl use CGI; print "This is test.fcgi!\n"; While trying to access it via http://www.website.dom/fcgi-bin/test.fcgi I get error 500 (Internal Server Error). Here is my vhost config: <VirtualHost 95.131.29.226:8080> ServerName website.com DocumentRoot /var/www/data/website.com SuexecUserGroup user group ServerAlias www.website.com AddType application/x-httpd-php .php .php3 .php4 .php5 .phtml <Directory "/var/www/data/website.com/fcgi-bin/"> Options +ExecCGI Allow from all Order allow,deny AddHandler fcgid-script .fcgi </Directory> </VirtualHost> fcgid.conf: <IfModule mod_fcgid.c> AddHandler fcgid-script .fcgi SocketPath /var/lib/apache2/fcgid/sock IdleTimeout 3600 ProcessLifeTime 7200 MaxProcessCount 8 DefaultMaxClassProcessCount 2 IPCConnectTimeout 8 IPCCommTimeout 60 </IfModule> SuExec log: [2010-04-06 03:02:47]: uid: (500/equ) gid: (502/equ) cmd: test.fcgi Apache error log: test! test! [Tue Apr 06 03:02:51 2010] [notice] mod_fcgid: process /var/www/data/website.com/fcgi-bin/test.fcgi(26267) exit(communication error), terminated by calling exit(), return code: 0 [Tue Apr 06 03:02:53 2010] [notice] mod_fcgid: process /var/www/data/website.com/fcgi-bin/test.fcgi(26261) exit(server exited), terminated by calling exit(), return code: 0 I've no clue why I'm getting error 500, but when I'm trying to access this file using console ($ perl /var/www/data/website.com/fcgin-bin/test.fcgi) everthing works fine without any errors... Any suggestions on how to solve this problem would be greatly appreciated. Thank you!

    Read the article

  • SSH over HTTPS with proxytunnel and nginx

    - by Thermionix
    I'm trying to setup an ssh over https connection using nginx. I haven't found any working examples, so any help would be appreciated! ~$ cat .ssh/config Host example.net Hostname example.net ProtocolKeepAlives 30 DynamicForward 8118 ProxyCommand /usr/bin/proxytunnel -p ssh.example.net:443 -d localhost:22 -E -v -H "User-Agent: Mozilla/4.0 (compatible; MSIE 6.0; Win32)" ~$ ssh [email protected] Local proxy ssh.example.net resolves to 115.xxx.xxx.xxx Connected to ssh.example.net:443 (local proxy) Tunneling to localhost:22 (destination) Communication with local proxy: -> CONNECT localhost:22 HTTP/1.0 -> Proxy-Connection: Keep-Alive -> User-Agent: Mozilla/4.0 (compatible; MSIE 6.0; Win32) <- <html> <- <head><title>400 Bad Request</title></head> <- <body bgcolor="white"> <- <center><h1>400 Bad Request</h1></center> <- <hr><center>nginx/1.0.5</center> <- </body> <- </html> analyze_HTTP: readline failed: Connection closed by remote host ssh_exchange_identification: Connection closed by remote host Nginx config on the server; ~$ cat /etc/nginx/sites-enabled/ssh upstream tunnel { server localhost:22; } server { listen 443; server_name ssh.example.net; location / { proxy_pass http://tunnel; proxy_set_header Host $host; proxy_set_header X-Real-IP $remote_addr; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_redirect off; } ssl on; ssl_certificate /etc/ssl/certs/server.cer; ssl_certificate_key /etc/ssl/private/server.key; } ~$ tail /var/log/nginx/access.log 203.xxx.xxx.xxx - - [08/Feb/2012:15:17:39 +1100] "CONNECT localhost:22 HTTP/1.0" 400 173 "-" "-"

    Read the article

  • Is one server on a vlan unnecessary?

    - by moomoochoo
    DETAILS I've been researching web hosting solutions in Japan. Based on this question one of the services available seems to be a VLAN. I've read about the advantages of such a system for a large organization, but there doesn't seem to be much information regarding smaller setups. I take that to mean that for one server it is likely to be unnecessary? My concern is that I don't know how many other servers are on the WAN, so regardless of how many servers I use a VLAN might still be a good idea. SERVER INFO One dedicated server would be used. It would not be virtualized. My Research so far Based on comments here, a VLAN would be useful for mitigating these problems. A user on another server could, either mistakenly or maliciously, assign one of your IP addresses to their server, resulting in a "duplicate IP" situation that would cause connectivity issues. A user on another server could poison the arp cache and potentially redirect traffic to snoop on communication intended to/from your server. (later in the discussion this point was said to be unrealistic.) QUESTION Is it worthwhile getting a vlan for one dedicated server? Will it be easier/the same/ harder to manage?

    Read the article

  • EC2 Configuration

    - by user123683
    I am trying to create a server structure for my EC2 account. The design I have chosen consists of 2 instances running in different availability zones, elastic load balancer, an auto-scaling group with cloudwatch monitoring configured and a security group defining rules for access to the instances. This setup is to support an online web application written in PHP. I am trying to decide what is a better policy: Store MySQL DB on a separate Instance Store MySQL DB on an attached EBS volume (from what i know auto-scaling will not replicate the attached EBS volume but will generate new instances from a chosen AMI - is this view correct?) Regards the AMI I plan to use a basic Amazon linux 64 bit AMI, and install bastille (maybe OSSEC) but I am looking to also use an encrypted file system. Are there any issues using an encrypted file system and communication between the DB and webapp i neeed to be aware of? Are there any comms issues using the encrypted filesystem on the instance housing the webapp I was going to launch a second instance or attach a second volume in the second availability zone to act as a standby for the database - I'm just looking for some suggestions about how to get the two DB's to talk - will this be a big task Regards updates for security is it best to create a recent snapshot and just relaunch and allow Amazon to install updates on launch or is the yum update mechanism a suitable alternative - is it better practice to relaunch instead of updates being installed which force a restart. I plan to create two AMI snapshots one for the app server and one for the DB each with the same security measures in place - is this a reasonable - I just figure it is a better policy than having additional applications that are unnecessary included in a AMI that I intend on using. My plan for backup is to create periodic snapshots of the webapp and DB instances (if I use an additional EBS volume instead of separate instances my understanding is that the EBS volume will persist in S3 storage in the event of an unexpected termination and I can create snapshots of the volume backup purposes). Thanks in advance for suggestions and advice. I am new to EC2 and I may have described unnecessary overkill but I want to try implement what can be considered a best practice solution so all advice is appreciated.

    Read the article

  • How can I get my routers to forward ports correctly?

    - by Giffyguy
    My network currently looks like this (simplified): Note that Router #2 is connected to the LAN interface of Router #1. This should be familiar to anyone who has seen a standard static-IP setup with an additional firewall for a residence or other small building. Router #1 is actually my cable gateway, but since it is a fully functional router/firewall, I am going to refer to it as a router. Now, I need to open various ports in both firewalls for incoming communication to my server - port 80 is a good example. So I've opened up port 80 in Router #2, and so far all incoming traffic at the public IP X.X.X.129 is being routed correctly. The problem is that I also need my server to respond to incoming traffic at the public IP X.X.X.130 on the WAN interface of Router #1. Naturally, I can't just tell Router #1 to forward port 80 to another public IP. Port forwarding is only supported when the traffic is being directed to the LAN subnet. I am willing to restructure my network topology if required, with the following conditions: Router #1 cannot have its WAN IP reassigned - X.X.X.130 is mandatory. Router #1 cannot be moved or disconnected from the cloud. The server cannot be given a second IP address. I would prefer the server to have a private IP address - e.g. 10.0.0.10 I'd like to keep Router #2, but it can have a private IP - e.g. 10.0.1.10 Following these rules, I need to get my server to receive incoming traffic on port 80 from both public IP addresses. Does anyone on SU know if this is possible? So far my only theories have been to set up a static route on either router, or to somehow combine my two subnets into a single subnet.

    Read the article

  • The physical working paradigm of a signal passing on wire.

    - by smwikipedia
    Hi, This may be more a question of physics, so pardon me if there's any inconvenience. When I study computer networks, I often read something like this in order to represent a signal, we place some voltage on one end of the wire and the other end will detect the voltage and thus the signal. So I am wondering how a signal exactly passes through wire? Here's my current understanding based on my formal knowledge about electronics: First we need a close circuit to constrain/hold the electronic field. When we place a voltage at somewhere A of the circuit, electronic field will start to build up within the circuit medium, this process should be as fast as light speed. And as the electronic field is being built up, the electrons within the circuit medium are moved, and thus electronic current occurs, and once the electronic current is strong enough to be detected at somewhere else B on the complete circuit, then B knows about what has happend at A and thus communication between A and B is achieved. The above is only talking about the process of sending a single voltage through wire. If there's a bitstream and we need to send a series of voltages, I am not sure which of the following is true: The 2nd voltage should only be sent from A after the 1st voltage has been detected at B, the time interval is time needed to stimulate the electronic field in the medium and form a detectable electronic current at B. Several different voltages could be sent on wire one by one, different electronic current values will exists along the wire simutaneously and arrive at B successively. I hope I made myself clear and someone else has ever pondered this question. (I tag this question with network cause I don't know if there's a better option.) Thanks, Sam

    Read the article

  • Fatal Execution Engine Error on the Windows2008 r2, IIS7.5

    - by user66524
    Hi Guys We are running some asp.net(3.5) applications on the Windows2008 r2, IIS7.5. Recently we got some event logs so difficult, we have not idea hope some guys can help. 1.EventID: 1334 (9-1-2011 8:41:57) Error message An error occurred during a process host idle check. Exception: System.AccessViolationException Message: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. StackTrace: at System.Collections.Hashtable.GetEnumerator() at System.Web.Hosting.ApplicationManager.IsIdle() at System.Web.Hosting.ProcessHost.IsIdle() 2.EventID: 1023 (9-1-2011 19:44:02) Error message .NET Runtime version 2.0.50727.4952 - Fatal Execution Engine Error (742B851A) (80131506) 3.EventID: 1000 (9-1-2011 19:44:03) Error message Faulting application name: w3wp.exe, version: 7.5.7600.16385, time stamp: 0x4a5bcd2b Faulting module name: mscorwks.dll, version: 2.0.50727.4952, time stamp: 0x4bebd49a Exception code: 0xc0000005 Fault offset: 0x0000c262 Faulting process id: 0x%9 Faulting application start time: 0x%10 Faulting application path: %11 Faulting module path: %12 Report Id: %13 4.EventID: 5011 (9-1-2011 19:44:03) Error message A process serving application pool 'AppPoolName' suffered a fatal communication error with the Windows Process Activation Service. The process id was '2552'. The data field contains the error number. 5.some info: we got the memory.hdmp(234MB) and minidump.mdmp(19.2) from control panel action center but I donot know how to use that :(

    Read the article

  • Service Unavailable - App Pool disabled error...anyone know why?

    - by andy
    Hi guys A small number of our sites intermediately experience an error that is a mystery to us. Our set up is: Windows Server 2003 IIS6 .NET 3.5 We have about 35 Websites running on IIS Each site has it's own App Pool Each App Pool has the identity: Network Service The symptom is: The Application Pool for a site stops, and when you browse to the site, you only see: SERVICE UNAVAILABLE In the Event Logs, we have one Error, that looks like this: Application pool 'AppPool1' is being automatically disabled due to a series of failures in the process(es) serving that application pool. And we have several Warnings leading up to the error, that look like this (note: the warnings look the same, except for the process id): A process serving application pool 'AppPool1' suffered a fatal communication error with the World Wide Web Publishing Service. The process id was '292'. The data field contains the error number. What's causing this? As I said, it doeasn't happen very often....the last time was about 6 months ago...and it usually happens with the same site/App pool. Any ideas? cheers!

    Read the article

  • windows cant "see" camera

    - by user330401
    So I bought a lil emerson camera and I am trying to get it to read the thing on windows 7. The instructions for the camer say when you first hook it up via usb AUTOPLAY will come up and your good to go. Well that worked for me the first time I hooked it up. However the 2nd time, it started trying to install drivers. Since then I can't get it to show up in windows explorer. I have tried disabling and uninstalling everything and trying to start from scratch but its useless, I'm stuck with having to pull the sd card everytime. I really dont like doing this as its a cheap camera, so if I can fix the communication between the devices via usb I would be really happy. As of right now the device installation shows a checked USB COMPOSITE DEVICE and 3 X'd GENERIC IMAGE DEVIC. Can someone please help me get this sorted. PS there are no drivers for this camera, not in the packaging, not available from emerson, and to be honest it shouldn't need any. The only function the camera has when hooked up via USB is charging and access to the DCIM. The charging still works, but the drive just won't load. Any suggestions?

    Read the article

  • What breaks in a Windows domain if a member has a high time skew?

    - by Ryan Ries
    It's taken for granted by most IT people that in a Windows domain, if a member server's clock is off by more than 5 minutes (or however many minutes you've configured it for) from that of its domain controller - logons and authentications will fail. But that is not necessarily true. At least not for all authentication processes on all versions of Windows. For instance, I can set my time on my Windows 7 client to be skewed all to heck - logoff/logon still works fine. What happens is that my client sends an AS_REQ (with his time stamp) to the domain controller, and the DC responds with KRB_AP_ERR_SKEW. But the magic is that when the DC responds with the aforementioned Kerberos error, the DC also includes his time stamp, which the client in turn uses to adjust his own time and resubmits the AS_REQ, which is then approved. This behavior is not considered a security threat because encryption and secrets are still being used in the communication. This is also not just a Microsoft thing. RFC 4430 describes this behavior. So my question is does anyone know when this changed? And why is it that other things fail? For instance, Office Communicator kicks me off if my clock starts drifting too far out. I really wish to have more detail on this. edit: Here's the bit from RFC 4430 that I'm talking about: If the server clock and the client clock are off by more than the policy-determined clock skew limit (usually 5 minutes), the server MUST return a KRB_AP_ERR_SKEW. The optional client's time in the KRB-ERROR SHOULD be filled out. If the server protects the error by adding the Cksum field and returning the correct client's time, the client SHOULD compute the difference (in seconds) between the two clocks based upon the client and server time contained in the KRB-ERROR message. The client SHOULD store this clock difference and use it to adjust its clock in subsequent messages. If the error is not protected, the client MUST NOT use the difference to adjust subsequent messages, because doing so would allow an attacker to construct authenticators that can be used to mount replay attacks.

    Read the article

  • Difference between "traceroute" and "traceroute -U"

    - by AndiDog
    The manpage of traceroute says that the "-U" parameter (UDP probing) is the default, but I'm getting different results every time. With "-U": traceroute -U www.univ-paris1.fr traceroute to www.univ-paris1.fr (193.55.96.121), 30 hops max, 60 byte packets [...] 13 rap-vl165-te3-2-jussieu-rtr-021.noc.renater.fr (193.51.181.101) 59.445 ms 56.924 ms 56.651 ms [...] 18 * paris1web.univ-paris1.fr (193.55.96.121) 23.797 ms 23.603 ms but the normal traceroute gives me another result (never reaches the final node) - it's either "!X" or just exits after the maximum of 30 hops: traceroute www.univ-paris1.fr traceroute to www.univ-paris1.fr (193.55.96.121), 30 hops max, 60 byte packets [...] 11 te1-1-paris1-rtr-021.noc.renater.fr (193.51.189.38) 28.147 ms 28.250 ms 28.538 ms [... non-responding nodes ...] 28 site-1.03-jussieu.rap.prd.fr (195.221.126.58) 85.941 ms !X * * Note: I tried this very often and always get the same results. The path in my local network is always the same. So what does the "-U" parameter actually change here? I'm especially interested what the reason for "!X" could be (communication administratively prohibited). EDIT: If that helps, paris-traceroute gives me the following for the last hop: 14 P(1, 6) site-1.03-jussieu.rap.prd.fr (195.221.126.58) 34.938 ms !5 !T2 which means that node discards the packet with TTL=2 and returns an unknown message (not "destination unreachable" or the like).

    Read the article

  • Fatal Execution Engine Error on the Windows2008 r2, IIS7.5

    - by user66524
    Hi Guys We are running some asp.net(3.5) applications on the Windows2008 r2, IIS7.5. Recently we got some event logs so difficult, we have not idea hope some guys can help. 1.EventID: 1334 (9-1-2011 8:41:57) Error message An error occurred during a process host idle check. Exception: System.AccessViolationException Message: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. StackTrace: at System.Collections.Hashtable.GetEnumerator() at System.Web.Hosting.ApplicationManager.IsIdle() at System.Web.Hosting.ProcessHost.IsIdle() 2.EventID: 1023 (9-1-2011 19:44:02) Error message .NET Runtime version 2.0.50727.4952 - Fatal Execution Engine Error (742B851A) (80131506) 3.EventID: 1000 (9-1-2011 19:44:03) Error message Faulting application name: w3wp.exe, version: 7.5.7600.16385, time stamp: 0x4a5bcd2b Faulting module name: mscorwks.dll, version: 2.0.50727.4952, time stamp: 0x4bebd49a Exception code: 0xc0000005 Fault offset: 0x0000c262 Faulting process id: 0x%9 Faulting application start time: 0x%10 Faulting application path: %11 Faulting module path: %12 Report Id: %13 4.EventID: 5011 (9-1-2011 19:44:03) Error message A process serving application pool 'AppPoolName' suffered a fatal communication error with the Windows Process Activation Service. The process id was '2552'. The data field contains the error number. 5.some info: we got the memory.hdmp(234MB) and minidump.mdmp(19.2) from control panel action center but I donot know how to use that :(

    Read the article

  • Why does just splitting an Ethernet cable not work?

    - by Sin Jeong-hun
    I thought the Ethernet is logically a one-line communication bus (for argument's sake, I am excluding hubs). All machines attached on the bus hears the same signals and the machines themselves try to avoid collisions by randomly backing off. http://computer.howstuffworks.com/ethernet6.htm If so, why would splitting one Ethernet line from my home router into two and connecting two computers not work? Why do I have to add a switch to it? *What the Internet said would not work. [4 port home router] ------[one Ethernet cable]-----[simple splitter]======[two computers] *What the Internet said I should do [4 port home router] ------[one Ethernet cable]-----[switch]======[two computers] Is this because of the signal degradation (reduced electric current)? Thank you for all the answers! The reason why I did not just use the two ports of my home router is... The 4-port gigabit router is in my room, and I had put a computer in another room (also my room, though). Since a wired network is far more reliable and secure, I had bought a long Ethernet cable and and connected the computer to the router. Now I was thinking about adding another computer to that room. I could buy another long Ethernet cable, but then there will be two cables between the rooms. The one line already is a minor annoyance, so I thought if I could share the one line between the two computers in that room. A switch would work, but it requires power and is a little bit pricey. That is why I wondered why it would not work to simply split the physical Ethernet cable. Apparently I do not completely understand how Ethernet and a switch work. I just have some bit of knowledge I heard in my college class.

    Read the article

  • I am unable to run a client/server program in php

    - by sibi
    This is the program I am trying to run: $host = "127.0.0.1"; $port = 25003; // don't timeout! set_time_limit(0); // create socket $socket = socket_create(AF_INET, SOCK_STREAM, 0) or die("Could not create socket\n"); // bind socket to port $result = socket_bind($socket, $host, $port) or die("Could not bind to socket\n"); // start listening for connections $result = socket_listen($socket, 3) or die("Could not set up socket listener\n"); // accept incoming connections // spawn another socket to handle communication $spawn = socket_accept($socket) or die("Could not accept incoming connection\n"); // read client input $input = socket_read($spawn, 1024) or die("Could not read input\n"); // clean up input string $input = trim($input); echo "Client Message : ".$input; // reverse client input and send back $output = strrev($input) . "\n"; socket_write($spawn, $output, strlen ($output)) or die("Could not write output\n"); // close sockets socket_close($spawn); socket_close($socket); I enabled the PHP_socket option in WAMP but still I keep getting errors like unable to bind. Can someone please help me out?

    Read the article

  • Security for university research lab systems

    - by ank
    Being responsible for security in a university computer science department is no fun at all. And I explain: It is often the case that I get a request for installation of new hw systems or software systems that are really so experimental that I would not dare put them even in the DMZ. If I can avoid it and force an installation in a restricted inside VLAN that is fine but occasionally I get requests that need access to the outside world. And actually it makes sense to have such systems have access to the world for testing purposes. Here is the latest request: A newly developed system that uses SIP is in the final stages of development. This system will enable communication with outside users (that is its purpose and the research proposal), actually hospital patients not so well aware of technology. So it makes sense to open it to the rest of the world. What I am looking for is anyone who has experience with dealing with such highly experimental systems that need wide outside network access. How do you secure the rest of the network and systems from this security nightmare without hindering research? Is placement in the DMZ enough? Any extra precautions? Any other options, methodologies?

    Read the article

  • Total newb having SSH and remote MySQL access problems

    - by kscott
    I don't often work with linux or need to SSH into remote MySQL databases, so pardon my ignorance. For months I had been using the HeidiSQL client application to remotely access a MySQL database. Today two things happened: the DB moved to a new server and I updated HeidiSQL, now I cannot log in to the MySQL server, when attempting I get this message from Heidi: SQL Error (2003) in statement #0: Can't connect to MySQL server on 'localhost' (10061) If I use Putty, I can connect to the server and get MySQL access through command line, including fetching data from the DB. I assume this means my credentials and address are correct, but do not understand why putting those same details into HeidiSQL's SSH tunnel info won't work. I also downloaded the MySQL Workbench and attempted to set up a connection through that client and got this message: Cannot Connect to Database Server Your connection attempt failed for user 'myusername' from your host to server at localhost:3306: Lost connection to MySQL server at 'reading initial communication packet', system error: 0 Please: 1 Check that mysql is running on server localhost 2 Check that mysql is running on port 3306 (note: 3306 is the default, but this can be changed) 3 Check the myusername has rights to connect to localhost from your address (mysql rights define what clients can connect to the server and from which machines) 4 Make sure you are both providing a password if needed and using the correct password for localhost connecting from the host address you're connecting from From Googling around I see that it could be related to the MySQL bind-address, but I am a third party sub-contractor with no access to the MySQL settings of this box and the system admin is assuring me that I'm an idiot and need to figure it out on my end. This is completely possible but I don't know what else to try. Edit 1 - The client settings I am using In Heidi and MySQL Workbench I am using the following: SSH host + port: theHostnameOfTheRemoteServer.com:22 {this is the same host I can Putty to} SSH Username: mySSHusername {the same user name I use for my Putty connection} SSH Password: mySSHpassword {the same password for the Putty connection} Local port: 3307 MySQL host: theHostnameOfTheRemoteServer.com MySQL User: mySQLusername {which I can connect with once in with Putty} MySQL Password: mySQLpassword {which works once in with Putty} Port: 3306

    Read the article

  • Thin client - cloud machine - to run via iPad, iPhone, most Androids etc

    - by Carl Lindberg
    I'm tired of having a laptop macbook that breaks down or having files that I need to sync via dropbox etc all the time via the machines to different OS installations. It sucks. I want a thin client where I can login on any machine - my iPhone, PC desktop, iPad etc to one running machine. I would like to replace a modernly powerful desktop iMac with a thin client running via my iPad. I will connect the iPad with a keyboard/mouse too so you get the idea. But I want to be able to use some of the Android phones as well (I guess most Android phones today has a good enough performance/resolution etc to run a thin client). Of course it has to be able to have input/output in sound. Printing can be solved by PDF/emailing etc - so no direct communication to the printer ports to USB etc is necessary. Is there such a service today? It should cost somewhere under something like $40/ month. I will run stuff like CPU heavy duty ableton for music production, xCode for making iOS apps, some games etc. And on the thin client also run virtual machines. VM of Ubuntu and Windows.

    Read the article

  • Hubs/switches taking out switches?

    - by Bart Silverstrim
    Here's the issue...we have a network with a lot of Cisco switches. Someone plugged in a hub on the network, and then we started seeing "weird" behavior; errors in communication between clients and servers, or network timeouts, dropping network connections, etc. It seemed that somehow that hub (or SOHO switch) was particularly freaking out our Cisco 3700 series switches. Disconnect that hub or netgear-type SOHO switch and things settled down again. We're in the process of trying to get a centralized logging server for SNMP and management, etc., to see if we can trap errors or narrow down when someone does this sort of thing without our knowledge because things seem to work, for the most part, without issue, we just get freaky oddball incidents on particular switches that don't seem to have any explanation until we find out someone decided to take matters into their own hands to expand available ports in their room. Without getting into procedure changes or locking down ports or "in our organization they'd be fired" answers, can someone explain why adding a small switch or hub, not necessarily a SOHO router (even a dumb hub apparently caused the 3700's to freak out) sending DHCP request out, will cause issues? The boss said it's because the Cisco's are getting confused because that rogue hub/switch is bridging multiple MAC's/IP's into one port on the Cisco switches and they just choke on that, but I thought their routing tables should be able to handle multiple machines coming into the port. Anyone see that behavior before and have a clearer explanation of what's happening? I'd like to know for future troubleshooting and better understanding that just waving my hand and saying "you just can't".

    Read the article

  • Port forwarding on D-Link DIR-615 super-slow, useless

    - by Jaroslav Záruba
    Hello I have replaced my old router with DIR-615 from D-Link, and now the port forwarding is so slow it makes the router practically useless for requests coming from outside of my network. Accessing the router itself (admin UI) from outside is without any issues, no delay whatsoever. But when I try to access a service residing on any of the computers in my network from outside the requests take minutes and minutes. (E.g. I can see source of my GWT-app main page, but loading additional CSS and JS files takes years.) If anyone could recommend any further diagnostics I should do to figure out what is happening it would be great. Few notes: happens with more services (web-app on Tomcat, viewing directory index via Apache) it does not make a difference whether the service is hosted on wired or wireless PC accessing the service on a localhost works fine, as does any 'inner' communication turning off firewall on target PC does not make difference either (makes sense) when I replace this router with the old one (both 192.168.1.1) everything works fine I see nothing suspicious in the router's log I believe I have the latest firmware (4.11) DIR-615 sucks, it already died once completely Regards Jarda Z.

    Read the article

  • how to maitain the authentication details/passwords in a 50 people company

    - by sabya
    What is the process that you guys follow to maintain authentication details like login ids and passwords? There will be definitely some shared passwords. So, the target is to minimize the impact when someone is leaving the company. By "shared password", I mean, the account, which is shared among multiple people in the company. The issues that the process should address are: - Affected areas. Quickly find the resources to which the leaving user was having access to. Forgetting password. What happens if a user forgets an authentication details? How does he get it? I think he shouldn't ask a team mate. I mean no-verbal communication. Find dependencies of a resource. Suppose I am changing the password for a mail account, which is getting used by some automated scripts to send mails. Here, the scripts are dependent on the mail account, so changing the password of the mail account means we have to change the password in the script too. So, how do find all the dependencies of a resource? I'd prefer a process which addresses these issues. But you can also recommend products which are open source and not hosted. I have gone through PassPack, but they don't solve #4. There is a similar question here. But that does not exactly answer my question.

    Read the article

  • Apache2.2 not responding on Windows 7 desktop

    - by Adam
    Afternoon! I'm having some trouble with Apache2.2 on Windows 7. For over a year it's been running no problem, but all of a sudden requests have just stopped responding. They don't ever time out, the browser just keeps on waiting for a response, which makes me think it's something blocking communication with Apache. Interestingly though, if I stop Apache the requests fail immediately. The Apache service is running, and using netstat I can see it listening on port 80 as configured: TCP 127.0.0.1:80 0.0.0.0:0 LISTENING If I stop the Apache service, that line disappears. I have an entry within my hosts file for each VHost I'm trying, all pointing to 127.0.0.1. Each VHost is configured to *:80. Nothing however is getting recorded in the access or error (at debug level) log files. I've verified the file paths are correct, even though they were never changed. Neither is anything getting recorded within Windows' Event Log. The problem showed up when I added a new VHost and restarted, however I hadn't been using it for a couple of days prior so I don't believe it's the config change. I have performed a syntax check to be sure, and when starting from the command prompt no errors are reported there. I do have Windows Firewall running, however I've verified the Apache rule is correct and tried turning it off to ensure that wasn't the problem. I've reinstalled Apache, in the hope it might magically fix something using the default config, but still no joy. I've also tried using a different port. I'm completely lost for ideas now. Can anybody help? Cheers Adam

    Read the article

  • Slow boot for OS and external devices

    - by Derek Van Cuyk
    I have been having this problem intermittently but as of yesterday, it has become more consistent. It originally started when I rebooted my PC at home and the OS (Windows 8) sat in a loop appearing to do nothing while loading. I figured since this was a new installation, that something may have just become corrupted and I decided to reinstall. So I tried to boot off of the thumb drive which had the installation iso and encountered pretty much the same issue. Same with the DVD drive. So, I rebooted once again and left it to load the entire night just to see if it ever would and sure enough this morning, Windows had finally loaded. Authentication had the same roblem albeit not quite as long (took about 5 minutes to authenticate). However, once I was in, everything appeared to be working fine and as quick as normal with the exception of when I tried to scan the C drive for any errors, which ran unbearably slow (45 minutes and before I left for work and was not finished scanning a 64GB SSD drive). I mention that I have had this issue but never when loading the OS. Before it occurred when trying to install windows 7 from a different DVD drive than the one I have now. It took me about 3 hours to do it since I had to wait sometimes 30+ min for each step to finish processing. Does anyone have an idea as to what can cause this? I am assuming it is the motherboard since it is responsible for communication with all the devices I'm having issues with but I cannot find anyone else who has had a problem like this and don't want to drop more money on a MB if it isn't the problem. Hardware: Motherboard: Asus M4A78T-E Socket AM3/ AMD 790GX/ Hybrid CrossFireX Hard Drive: Kingston SSDNow V+180 64GB Micro SATA II 3GB/S 1.8 Inch Solid State Drive SVP180S2/64G Optical Drive: Samsung Blu-Ray Combo Internal 12XReadable and DVD-Writable Drive with Lightscribe SH-B123L/BSBP Thanks, Derek

    Read the article

  • Cannot connect to Solaris Server when Oracle GoldenGate process uses the port

    - by Abdallah Ghrb
    I'm trying to test the Oracle goldengate to replicate data between two databases on the same server. So I installed two databases and two goldengate homes in the same machine. The goldengate processes are started from each home and they are responsible for the replication : Process from home 1 configured on port 7809 & process for home 2 configured on port 7810. For a successful replication, processes started from goldengate home 1 should communicate with processes started from goldengate home 2. But for some reasons, this is not happening. The goldengate log file has the following error : OGG-01223 Oracle GoldenGate Capture for Oracle, exthrr.prm: TCP/IP error 131 (Connection reset by peer). "Googling" for this error, it said that the connection occurred but the host terminated it. Tried to telnet the machine with the used port and it gave the following error: bash-3.00$ telnet 10.10.3.124 7810 Trying 10.10.3.124... Connected to 10.10.3.124. Escape character is '^]'. Connection to 10.10.3.124 closed by foreign host. Here the communication occurs but for only around 3 seconds then it is closed by the host, which is the same explanation of the above error in the goldengate log file. I tried to change the port but still the same error. The problem is happening only when the goldengate process is using the port. When other process is using the same port, I can telnet successfully.

    Read the article

  • Postfix unable to find local server

    - by Andrew
    I'm working with postfix on fedora 9 and I'm attempting to make some changes to a system setup by my predecessor. Currently the postfix server on [mail.ourdomain.com] is setup to forward mail sent to two addresses to another server for processing. The other server [www01.ourdomain.com] receives the email and sends it to a PHP script to be processed. Then that PHP script generates and sends a response to the user who sent the original email. We're adding more web servers to the system and as a result we've decided to move these processing scripts to our admin [admin.ourdomain.com] server to make them easier to keep track of. I've already setup and tested the processing scripts on [admin.ourdomain.com], and on the mail server doing the forwarding [mail.ourdomain.com] I added [admin.ourdomain.com] to /etc/hosts and also added another, aside from the one for [www01.ourdomain.com], entry to /etc/postfix/transport for [admin.ourdomain.com]. I also restarted postfix as well. I've tested the communication from [mail.ourdomain.com] to [admin.ourdomain.com] using telnet and the [admin.ourdomain.com] domain and everything runs correctly. But as soon as I change the forward address and attempt to send an email to the mail server I get a bounce message stating "Host or domain name not found. Name service error for name=admin.ourdomain.com type=A: Host not found". If I change the forward settings back to [www01.ourdomain.com] then everything works fine. Is there some setting I'm missing in Postfix? The server itself and telnet work fine it just seems to be postfix that's not able to discover the location of [admin.ourdomain.com].

    Read the article

  • Some free cloud solution to enhance your business

    - by Saif Bechan
    I am co-owner of a small internet business. I am in charge of IT, and I try to get things done as low cost as possible. When investing in servers, resources and overall business costs your project can soon turn into a financial disaster. Cloud solutions can help you in solving some financial problems, they can help you in scalability problems, and overall performance problems of your server or web application. Recently I moved the whole internal/external communication(email,calendar,documents) of my business to the cloud. I did this by using the free version of Google Apps. This works great and is a big advantage on multiple levels. I do not have to fight spam anymore on my system, and there are less resources used on my system. Also switching servers will go a lot easier. Questions Can you name some cloud solution that you have used, or some you just recommend. They can fairy form financial benefits, organizational benefits, performance benefits. It doesn't matter as soon as it helps you spread the load of your business.

    Read the article

< Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >