Search Results

Search found 23350 results on 934 pages for 'general event'.

Page 75/934 | < Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >

  • Mootools event leak

    - by user572263
    The example to demonstrate the issue can be found here: link text The test shows a basic Mootools class that contains an element variable with a click event attached. There’s also a “cleanup” function to remove the event and nullify the element variable. My problem is that when I loop a thousand times to create the “LeakClass” instance and clean it up, it causes a major memory leak like there’s no tomorrow. I tested this on IE8 and Chrome. On the other hand what I’ve noticed is that if I comment out the line that adds the “click” event, the code doesn’t leak. Can somebody please help me structure the class/event in a manner that it doesn’t leak. Thanks in advance.

    Read the article

  • c# event and delegate question

    - by user359562
    I want to detach the custom event but could not detach. Please find below I am using -= to detach the event. I assume after this, TextChanged2 method should not be invoked as I have unregistered the event. Let me know if my understanding is wrong. public delegate void TextChangedEventHandler1(object sender, TextBoxargs ta); public event TextChangedEventHandler1 TextChanged1; private void textBox1_TextChanged(object sender, EventArgs e) { this.TextChanged1 -= new TextChangedEventHandler1(TextChanged2); TextChanged2(sender, e); } public void TextChanged2(object sender, EventArgs e) { textBox1.Text = textBox1.Text.ToUpper(); }

    Read the article

  • poll(2) doesn't empty the event queue

    - by sasayins
    Hi, Im using linux as my programming platform. I am using poll(2) to know if my device is triggering an event. The first call of poll is ok, it blocks and wait for the event to happen. But in the second poll function call, it will return but it capture the event. Below are my code ret = poll( fds, 1, 2000); //2 secs timeout if( fds[0].revents & POLLIN && ret > 0) { printf("event occur\n"); } It seems the queue/buffer is not empty, im just assuming. What do you think is the problem? Thanks.

    Read the article

  • Why isn't this working - using :not() with an event handler

    - by james emanon
    I seem to have another issue that I am not conquering. Real simple premise. I have a mousedown event, and basically IF one particular element on the page is clicked, I want nothing to happen, else I want hide() some div. $(function(){ $("document :not(#_ignorelement)").mousedown(function(event){ if($('#_hidethiselement').length){ $('#_hidethiselement').hide(); } }) }) That is not working at all. I also tried the following: $(document).not($("#_ignorelement")).mousedown(function(event){ $(document).not("_ignorelement").mousedown(function(event){ IF I can solve that, curious how I would actually have ":not" encompass the parent div, like so: $().not("_ignoreelement").parent().closest('div').mousedown(function Because the element "_ignorelement" is an anchor tag that is in a div. Wonder how I can use the parent div perhaps, instead of the anchor tag. Anyways, any help would be appreciated.

    Read the article

  • System Account Logon Failures ever 30 seconds

    - by floyd
    We have two Windows 2008 R2 SP1 servers running in a SQL failover cluster. On one of them we are getting the following events in the security log every 30 seconds. The parts that are blank are actually blank. Has anyone seen similar issues, or assist in tracking down the cause of these events? No other event logs show anything relevant that I can tell. Log Name: Security Source: Microsoft-Windows-Security-Auditing Date: 10/17/2012 10:02:04 PM Event ID: 4625 Task Category: Logon Level: Information Keywords: Audit Failure User: N/A Computer: SERVERNAME.domainname.local Description: An account failed to log on. Subject: Security ID: SYSTEM Account Name: SERVERNAME$ Account Domain: DOMAINNAME Logon ID: 0x3e7 Logon Type: 3 Account For Which Logon Failed: Security ID: NULL SID Account Name: Account Domain: Failure Information: Failure Reason: Unknown user name or bad password. Status: 0xc000006d Sub Status: 0xc0000064 Process Information: Caller Process ID: 0x238 Caller Process Name: C:\Windows\System32\lsass.exe Network Information: Workstation Name: SERVERNAME Source Network Address: - Source Port: - Detailed Authentication Information: Logon Process: Schannel Authentication Package: Kerberos Transited Services: - Package Name (NTLM only): - Key Length: 0 Second event which follows every one of the above events Log Name: Security Source: Microsoft-Windows-Security-Auditing Date: 10/17/2012 10:02:04 PM Event ID: 4625 Task Category: Logon Level: Information Keywords: Audit Failure User: N/A Computer: SERVERNAME.domainname.local Description: An account failed to log on. Subject: Security ID: NULL SID Account Name: - Account Domain: - Logon ID: 0x0 Logon Type: 3 Account For Which Logon Failed: Security ID: NULL SID Account Name: Account Domain: Failure Information: Failure Reason: An Error occured during Logon. Status: 0xc000006d Sub Status: 0x80090325 Process Information: Caller Process ID: 0x0 Caller Process Name: - Network Information: Workstation Name: - Source Network Address: - Source Port: - Detailed Authentication Information: Logon Process: Schannel Authentication Package: Microsoft Unified Security Protocol Provider Transited Services: - Package Name (NTLM only): - Key Length: 0 EDIT UPDATE: I have a bit more information to add. I installed Network Monitor on this machine and did a filter for Kerberos traffic and found the following which corresponds to the timestamps in the security audit log. A Kerberos AS_Request Cname: CN=SQLInstanceName Realm:domain.local Sname krbtgt/domain.local Reply from DC: KRB_ERROR: KDC_ERR_C_PRINCIPAL_UNKOWN I then checked the security audit logs of the DC which responded and found the following: A Kerberos authentication ticket (TGT) was requested. Account Information: Account Name: X509N:<S>CN=SQLInstanceName Supplied Realm Name: domain.local User ID: NULL SID Service Information: Service Name: krbtgt/domain.local Service ID: NULL SID Network Information: Client Address: ::ffff:10.240.42.101 Client Port: 58207 Additional Information: Ticket Options: 0x40810010 Result Code: 0x6 Ticket Encryption Type: 0xffffffff Pre-Authentication Type: - Certificate Information: Certificate Issuer Name: Certificate Serial Number: Certificate Thumbprint: So appears to be related to a certificate installed on the SQL machine, still dont have any clue why or whats wrong with said certificate. It's not expired etc.

    Read the article

  • Windows Software RAID 5 Drive Failure Notification

    - by Wayne Hartman
    I plan on creating a Windows software RAID 5 array but need to know when a drive goes bum. I don't plan on wanting to check the server every so often, so how can I have an email sent when a drive goes kapüt or otherwise has problems? Keying off the event log would be OK, but how does one set up notifications on it when the exact event ID(s) may not be known?

    Read the article

  • ArgumentError: Error #1063: Argument count mismatch on com.flashden::MenuItem(). Expected 1, got 0.

    - by Suzanne
    I keep getting the below error only in firefox ArgumentError: Error #1063: Argument count mismatch on com.flashden::MenuItem(). Expected 1, got 0. at flash.display::Sprite/constructChildren() at flash.display::Sprite() at flash.display::MovieClip() at com.flashden::Preview() Below is my menu script: package com.flashden { import flash.display.MovieClip; import flash.text.; import flash.events.MouseEvent; import flash.events.; import flash.net.URLRequest; import flash.display.Loader; public class MenuItem extends MovieClip { private var scope; public var closedX :Number public static const OPEN_MENU = "openMenu"; function callLink(event:MouseEvent):void { public function MenuItem(scope) { // set scope to talk back to -------------------------------// this.scope = scope; // disable all items not to be clickable -------------------// txt_label.mouseEnabled = false; menuItemShine.mouseEnabled = false; menuItemArrow.mouseEnabled = false; // make background clip the item to be clicked (button) ----// menuItemBG.buttonMode = true; // add click event listener to the header background -------// menuItemBG.addEventListener(MouseEvent.CLICK, clickHandler); } private function clickHandler (e:MouseEvent) { scope.openMenuItem(this); } public function loadContent (contentURL:String) { var loader:Loader = new Loader(); configureListeners(loader.contentLoaderInfo); var request:URLRequest = new URLRequest(contentURL); loader.load(request); // place x position of content at the bottom of the header so the top is not cut off ----// loader.x = 35; // we add the content at level 1, because the background clip is at level 0 ----// addChildAt(loader, 0); } private function configureListeners(dispatcher:IEventDispatcher):void { dispatcher.addEventListener(Event.COMPLETE, completeHandler); dispatcher.addEventListener(HTTPStatusEvent.HTTP_STATUS, httpStatusHandler); dispatcher.addEventListener(Event.INIT, initHandler); dispatcher.addEventListener(IOErrorEvent.IO_ERROR, ioErrorHandler); dispatcher.addEventListener(Event.OPEN, openHandler); dispatcher.addEventListener(ProgressEvent.PROGRESS, progressHandler); dispatcher.addEventListener(Event.UNLOAD, unLoadHandler); } private function completeHandler(event:Event):void { //trace("completeHandler: " + event); // remove loader animation ----------------// removeChild(getChildByName("mc_preloader")); } private function httpStatusHandler(event:HTTPStatusEvent):void { // trace("httpStatusHandler: " + event); } private function initHandler(event:Event):void { //trace("initHandler: " + event); } private function ioErrorHandler(event:IOErrorEvent):void { //trace("ioErrorHandler: " + event); } private function openHandler(event:Event):void { //trace("openHandler: " + event); } private function progressHandler(event:ProgressEvent):void { //trace("progressHandler: bytesLoaded=" + event.bytesLoaded + " bytesTotal=" + event.bytesTotal); } private function unLoadHandler(event:Event):void { //trace("unLoadHandler: " + event); } } } Any idea why this is happening?

    Read the article

  • Calling a function that resides in the main page from a plugin?

    - by Justin Lee
    I want to call a function from within plugin, but the function is on the main page and not the plugin's .js file. EDIT I have jQuery parsing a very large XML file and building, subsequently, a large list (1.1 MB HTML file when dynamic content is copied, pasted, then saved) that has expand/collapse functionality through a plugin. The overall performance on IE is super slow and doggy, assuming since the page/DOM is so big. I am currently trying to save the collapsed content in the event.data when it is collapsed and remove it from the DOM, then bring it back when it is told to expand... the issue that I am having is that when I bring the content back, obviously the "click" and "hover" events are gone. I'm trying to re-assign them, currently doing so inside the plugin after the plugin expands the content. The issue then though is that is says the function that I declare within the .click() is not defined. Also the hover event doesn't seem to be re-assigning either.... if ($(event.data.trigger).attr('class').indexOf('collapsed') != -1 ) { // if expanding // console.log(event.data.targetContent); $(event.data.trigger).after(event.data.targetContent); $(event.data.target).hide(); /* This Line --->*/ $(event.data.target + 'a.addButton').click(addResourceToList); $(event.data.target + 'li.resource') .hover( function() { if (!($(this).attr("disabled"))) { $(this).addClass("over"); $(this).find("a").css({'display':'block'}); } }, function () { if (!($(this).attr("disabled"))) { $(this).removeClass("over"); $(this).children("a").css({'display':'none'}); } } ); $(event.data.target).css({ "height": "0px", "padding-top": "0px", "padding-bottom": "0px", "margin-top": "0px", "margin-bottom": "0px"}); $(event.data.target).show(); $(event.data.target).animate({ height: event.data.heightVal + "px", paddingTop: event.data.topPaddingVal + "px", paddingBottom: event.data.bottomPaddingVal + "px", marginTop: event.data.topMarginVal + "px", marginBottom: event.data.bottomMarginVal + "px"}, "normal");//, function(){$(this).hide();}); $(event.data.trigger).removeClass("collapsed"); $.cookies.set('jcollapserSub_' + event.data.target, 'expanded', {hoursToLive: 24 * 365}); } else if ($(event.data.trigger).attr('class').indexOf('collapsed') == -1 ) { // if collapsing $(event.data.target).animate({ height: "0px", paddingTop: "0px", paddingBottom: "0px", marginTop: "0px", marginBottom: "0px"}, "normal", function(){$(this).hide();$(this).remove();}); $(event.data.trigger).addClass("collapsed"); $.cookies.set('jcollapserSub_' + event.data.target, 'collapsed', {hoursToLive: 24 * 365}); } EDIT So, having new eyes truly makes a difference. As I was reviewing the code in this post this morning after being away over the weekend, I found where I had err'd. This: $(event.data.target + 'a.addButton').click(addResourceToList); Should be this (notice the space before a.addbutton): $(event.data.target + ' a.addButton').click(addResourceToList); Same issue with the "li.resource". So it was never pointing to the right elements... Thank you, Rene, for your help!!

    Read the article

  • OIM 11g notification framework

    - by Rajesh G Kumar
    OIM 11g has introduced an improved and template based Notifications framework. New release has removed the limitation of sending text based emails (out-of-the-box emails) and enhanced to support html features. New release provides in-built out-of-the-box templates for events like 'Reset Password', 'Create User Self Service' , ‘User Deleted' etc. Also provides new APIs to support custom templates to send notifications out of OIM. OIM notification framework supports notification mechanism based on events, notification templates and template resolver. They are defined as follows: Ø Events are defined as XML file and imported as part of MDS database in order to make notification event available for use. Ø Notification templates are created using OIM advance administration console. The template contains the text and the substitution 'variables' which will be replaced with the data provided by the template resolver. Templates support internationalization and can be defined as HTML or in form of simple text. Ø Template resolver is a Java class that is responsible to provide attributes and data to be used at runtime and design time. It must be deployed following the OIM plug-in framework. Resolver data provided at design time is to be used by end user to design notification template with available entity variables and it also provides data at runtime to replace the designed variable with value to be displayed to recipients. Steps to define custom notifications in OIM 11g are: Steps# Steps 1. Define the Notification Event 2. Create the Custom Template Resolver class 3. Create Template with notification contents to be sent to recipients 4. Create Event triggering spots in OIM 1. Notification Event metadata The Notification Event is defined as XML file which need to be imported into MDS database. An event file must be compliant with the schema defined by the notification engine, which is NotificationEvent.xsd. The event file contains basic information about the event.XSD location in MDS database: “/metadata/iam-features-notification/NotificationEvent.xsd”Schema file can be viewed by exporting file from MDS using weblogicExportMetadata.sh script.Sample Notification event metadata definition: 1: <?xml version="1.0" encoding="UTF-8"?> 2: <Events xmlns:xsi=http://www.w3.org/2001/XMLSchema-instance xsi:noNamespaceSchemaLocation="../../../metadata/NotificationEvent.xsd"> 3: <EventType name="Sample Notification"> 4: <StaticData> 5: <Attribute DataType="X2-Entity" EntityName="User" Name="Granted User"/> 6: </StaticData> 7: <Resolver class="com.iam.oim.demo.notification.DemoNotificationResolver"> 8: <Param DataType="91-Entity" EntityName="Resource" Name="ResourceInfo"/> 9: </Resolver> 10: </EventType> 11: </Events> Line# Description 1. XML file notation tag 2. Events is root tag 3. EventType tag is to declare a unique event name which will be available for template designing 4. The StaticData element lists a set of parameters which allow user to add parameters that are not data dependent. In other words, this element defines the static data to be displayed when notification is to be configured. An example of static data is the User entity, which is not dependent on any other data and has the same set of attributes for all event instances and notification templates. Available attributes are used to be defined as substitution tokens in the template. 5. Attribute tag is child tag for StaticData to declare the entity and its data type with unique reference name. User entity is most commonly used Entity as StaticData. 6. StaticData closing tag 7. Resolver tag defines the resolver class. The Resolver class must be defined for each notification. It defines what parameters are available in the notification creation screen and how those parameters are replaced when the notification is to be sent. Resolver class resolves the data dynamically at run time and displays the attributes in the UI. 8. The Param DataType element lists a set of parameters which allow user to add parameters that are data dependent. An example of the data dependent or a dynamic entity is a resource object which user can select at run time. A notification template is to be configured for the resource object. Corresponding to the resource object field, a lookup is displayed on the UI. When a user selects the event the call goes to the Resolver class provided to fetch the fields that are displayed in the Available Data list, from which user can select the attribute to be used on the template. Param tag is child tag to declare the entity and its data type with unique reference name. 9. Resolver closing tag 10 EventType closing tag 11. Events closing tag Note: - DataType needs to be declared as “X2-Entity” for User entity and “91-Entity” for Resource or Organization entities. The dynamic entities supported for lookup are user, resource, and organization. Once notification event metadata is defined, need to be imported into MDS database. Fully qualified resolver class name need to be define for XML but do not need to load the class in OIM yet (it can be loaded later). 2. Coding the notification resolver All event owners have to provide a resolver class which would resolve the data dynamically at run time. Custom resolver class must implement the interface oracle.iam.notification.impl.NotificationEventResolver and override the implemented methods with actual implementation. It has 2 methods: S# Methods Descriptions 1. public List<NotificationAttribute> getAvailableData(String eventType, Map<String, Object> params); This API will return the list of available data variables. These variables will be available on the UI while creating/modifying the Templates and would let user select the variables so that they can be embedded as a token as part of the Messages on the template. These tokens are replaced by the value passed by the resolver class at run time. Available data is displayed in a list. The parameter "eventType" specifies the event Name for which template is to be read.The parameter "params" is the map which has the entity name and the corresponding value for which available data is to be fetched. Sample code snippet: List<NotificationAttribute> list = new ArrayList<NotificationAttribute>(); long objKey = (Long) params.get("resource"); //Form Field details based on Resource object key HashMap<String, Object> formFieldDetail = getObjectFormName(objKey); for (Iterator<?> itrd = formFieldDetail.entrySet().iterator(); itrd.hasNext(); ) { NotificationAttribute availableData = new NotificationAttribute(); Map.Entry formDetailEntrySet = (Entry<?, ?>)itrd.next(); String fieldLabel = (String)formDetailEntrySet.getValue(); availableData.setName(fieldLabel); list.add(availableData); } return list; 2. Public HashMap<String, Object> getReplacedData(String eventType, Map<String, Object> params); This API would return the resolved value of the variables present on the template at the runtime when notification is being sent. The parameter "eventType" specifies the event Name for which template is to be read.The parameter "params" is the map which has the base values such as usr_key, obj_key etc required by the resolver implementation to resolve the rest of the variables in the template. Sample code snippet: HashMap<String, Object> resolvedData = new HashMap<String, Object>();String firstName = getUserFirstname(params.get("usr_key"));resolvedData.put("fname", firstName); String lastName = getUserLastName(params.get("usr_key"));resolvedData.put("lname", lastname);resolvedData.put("count", "1 million");return resolvedData; This code must be deployed as per OIM 11g plug-in framework. The XML file defining the plug-in is as below: <?xml version="1.0" encoding="UTF-8"?> <oimplugins xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <plugins pluginpoint="oracle.iam.notification.impl.NotificationEventResolver"> <plugin pluginclass= " com.iam.oim.demo.notification.DemoNotificationResolver" version="1.0" name="Sample Notification Resolver"/> </plugins> </oimplugins> 3. Defining the template To create a notification template: Log in to the Oracle Identity Administration Click the System Management tab and then click the Notification tab From the Actions list on the left pane, select Create On the Create page, enter values for the following fields under the Template Information section: Template Name: Demo template Description Text: Demo template Under the Event Details section, perform the following: From the Available Event list, select the event for which the notification template is to be created from a list of available events. Depending on your selection, other fields are displayed in the Event Details section. Note that the template Sample Notification Event created in the previous step being used as the notification event. The contents of the Available Data drop down are based on the event XML StaticData tag, the drop down basically lists all the attributes of the entities defined in that tag. Once you select an element in the drop down, it will show up in the Selected Data text field and then you can just copy it and paste it into either the message subject or the message body fields prefixing $ symbol. Example if list has attribute like First_Name then message body will contains this as $First_Name which resolver will parse and replace it with actual value at runtime. In the Resource field, select a resource from the lookup. This is the dynamic data defined by the Param DataType element in the XML definition. Based on selected resource getAvailableData method of resolver will be called to fetch the resource object attribute detail, if method is overridden with required implementation. For current scenario, Map<String, Object> params will get populated with object key as value and key as “resource” in the map. This is the only input will be provided to resolver at design time. You need to implement the further logic to fetch the object attributes detail to populate the available Data list. List string should not have space in between, if object attributes has space for attribute name then implement logic to replace the space with ‘_’ before populating the list. Example if attribute name is “First Name” then make it “First_Name” and populate the list. Space is not supported while you try to parse and replace the token at run time with real value. Make a note that the Available Data and Selected Data are used in the substitution tokens definition only, they do not define the final data that will be sent in the notification. OIM will invoke the resolver class to get the data and make the substitutions. Under the Locale Information section, enter values in the following fields: To specify a form of encoding, select either UTF-8 or ASCII. In the Message Subject field, enter a subject for the notification. From the Type options, select the data type in which you want to send the message. You can choose between HTML and Text/Plain. In the Short Message field, enter a gist of the message in very few words. In the Long Message field, enter the message that will be sent as the notification with Available data token which need to be replaced by resolver at runtime. After you have entered the required values in all the fields, click Save. A message is displayed confirming the creation of the notification template. Click OK 4. Triggering the event A notification event can be triggered from different places in OIM. The logic behind the triggering must be coded and plugged into OIM. Examples of triggering points for notifications: Event handlers: post process notifications for specific data updates in OIM users Process tasks: to notify the users that a provisioning task was executed by OIM Scheduled tasks: to notify something related to the task The scheduled job has two parameters: Template Name: defines the notification template to be sent User Login: defines the user record that will provide the data to be sent in the notification Sample Code Snippet: public void execute(String templateName , String userId) { try { NotificationService notService = Platform.getService(NotificationService.class); NotificationEvent eventToSend=this.createNotificationEvent(templateName,userId); notService.notify(eventToSend); } catch (Exception e) { e.printStackTrace(); } } private NotificationEvent createNotificationEvent(String poTemplateName, String poUserId) { NotificationEvent event = new NotificationEvent(); String[] receiverUserIds= { poUserId }; event.setUserIds(receiverUserIds); event.setTemplateName(poTemplateName); event.setSender(null); HashMap<String, Object> templateParams = new HashMap<String, Object>(); templateParams.put("USER_LOGIN",poUserId); event.setParams(templateParams); return event; } public HashMap getAttributes() { return null; } public void setAttributes() {} }

    Read the article

  • Issuing Current Time Increments in StreamInsight (A Practical Example)

    The issuing of a Current Time Increment, Cti, in StreamInsight is very definitely one of the most important concepts to learn if you want your Streams to be responsive. A full discussion of how to issue Ctis is beyond the scope of this article but a very good explanation in addition to Books Online can be found in these three articles by a member of the StreamInsight team at Microsoft, Ciprian Gerea. Time in StreamInsight Series http://blogs.msdn.com/b/streaminsight/archive/2010/07/23/time-in-streaminsight-i.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/07/30/time-in-streaminsight-ii.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/08/03/time-in-streaminsight-iii.aspx A lot of the problems I see with unresponsive or stuck streams on the MSDN Forums are to do with how Ctis are enqueued or in a lot of cases not enqueued. If you enqueue events and never enqueue a Cti then StreamInsight will be perfectly happy. You, on the other hand, will never see data on the output as you have not told StreamInsight to flush the stream. This article deals with a specific implementation problem I had recently whilst working on a StreamInsight project. I look at some possible options and discuss why they would not work before showing the way I solved the problem. The stream of data I was dealing with on this project was very bursty that is to say when events were flowing they came through very quickly and in large numbers (1000 events/sec), but when the stream calmed down it could be a few seconds between each event. When enqueuing events into the StreamInsight engne it is best practice to do so with a StartTime that is given to you by the system producing the event . StreamInsight processes events and it doesn't matter whether those events are being pushed into the engine by a source system or the events are being read from something like a flat file in a directory somewhere. You can apply the same logic and temporal algebra to both situations. Reading from a file is an excellent example of where the time of the event on the source itself is very important. We could be reading that file a long time after it was written. Being able to read the StartTime from the events allows us to define windows that will hold the correct sets of events. I was able to do this with my stream but this is where my problems started. Below is a very simple script to create a SQL Server table and populate it with sample data that will show exactly the problem I had. CREATE TABLE [dbo].[t] ( [c1] [int] PRIMARY KEY, [c2] [datetime] NULL ) INSERT t VALUES (1,'20100810'),(2,'20100810'),(3,'20100810') Column c2 defines the StartTime of the event on the source and as you can see the values in all 3 rows of data is the same. If we read Ciprian’s articles we know that we can define how Ctis get injected into the stream in 3 different places The Stream Definition The Input Factory The Input Adapter I personally have always been a fan of enqueing Ctis through the factory. Below is code typical of what I would use to do this On the class itself I do some inheriting public class SimpleInputFactory : ITypedInputAdapterFactory<SimpleInputConfig>, ITypedDeclareAdvanceTimeProperties<SimpleInputConfig> And then I implement the following function public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.FromTicks(-1)), AdvanceTimePolicy.Adjust); } The configInfo .CtiFrequency property is a value I pass through to define after how many events I want a Cti to be injected and this in turn will flush through the stream of data. I usually pass a value of 1 for this setting. The second parameter determines the CTI timestamp in terms of a delay relative to the events. -1 ticks in the past results in 1 tick in the future, i.e., ahead of the event. The problem with this method though is that if consecutive events have the same StartTime then only one of those events will be enqueued. In this example I use the following to define how I assign the StartTime of my events currEvent.StartTime = (DateTimeOffset)dt.c2; If I go ahead and run my StreamInsight process with this configuration i can see on the output adapter that two events have been removed To see this in a little more depth I can use the StreamInsight Debugger and see what happens internally. What is happening here is that the first event arrives and a Cti is injected with a time of 1 tick after the StartTime of that event (Also the EndTime of the event). The second event arrives and it has a StartTime of before the Cti and even though we specified AdvanceTimePolicy.Adjust on the factory we know that a point event can never be adjusted like this and the event is dropped. The same happens for the third event as well (The second and third events get trumped by the Cti). For a more detailed discussion of why this happens look here http://www.sqlis.com/sqlis/post/AdvanceTimePolicy-and-Point-Event-Streams-In-StreamInsight.aspx We end up with a single event being pushed into the output adapter and our result now makes sense. The next way I tried to solve this problem by changing the value of the second parameter to TimeSpan.Zero Here is how my factory code now looks public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.Zero), AdvanceTimePolicy.Adjust); } What I am doing here is declaring a policy that says inject a Cti together with every event and stamp it with a StartTime that is equal to the start time of the event itself (TimeSpan.Zero). This method has plus points as well as a downside. The upside is that no events will be lost by having the same StartTime as previous events. The Downside is that because the Cti is declared with the StartTime of the event itself then it does not actually flush that particular event because in the StreamInsight algebra, a Cti commits only those events that occurred strictly before them. To flush the events we need a Cti to be enqueued with a greater StartTime than the events themselves. Here is what happened when I ran this configuration As you can see all we got through was the Cti and none of the events. The debugger output shows the stamps on the Cti and the events themselves. Because the Cti issued has the same timestamp (StartTime) as the events then none of the events get flushed. I was nearly there but not quite. Because my stream was bursty it was possible that the next event would not come along for a few seconds and this was far too long for an event to be enqueued and not be flushed to the output adapter. I needed another solution. Two possible solutions crossed my mind although only one of them made sense when I explored it some more. Where multiple events have the same StartTime I could add 1 tick to the first event, two to the second, three to third etc thereby giving them unique StartTime values. Add a timer to manually inject Ctis The problem with the first implementation is that I would be giving the events a new StartTime. This would cause me the following problems If I want to define windows over the stream then some events may not be captured in the right windows and therefore any calculations on those windows I did would be wrong What would happen if we had 10,000 events with the same StartTime? I would enqueue them with StartTime + n ticks. Along comes a genuine event with a StartTime of the very first event + 1 tick. It is now too far in the past as far as my stream is concerned and it would be dropped. Not what I would want to do at all. I decided then to look at the Timer based solution I created a timer on my input adapter that elapsed every 200ms. private Timer tmr; public SimpleInputAdapter(SimpleInputConfig configInfo) { ctx = new SimpleTimeExtractDataContext(configInfo.ConnectionString); this.configInfo = configInfo; tmr = new Timer(200); tmr.Elapsed += new ElapsedEventHandler(t_Elapsed); tmr.Enabled = true; } void t_Elapsed(object sender, ElapsedEventArgs e) { ts = DateTime.Now - dtCtiIssued; if (ts.TotalMilliseconds >= 200 && TimerIssuedCti == false) { EnqueueCtiEvent(System.DateTime.Now.AddTicks(-100)); TimerIssuedCti = true; } }   In the t_Elapsed event handler I find out the difference in time between now and when the last event was processed (dtCtiIssued). I then check to see if that is greater than or equal to 200ms and if the last issuing of a Cti was done by the timer or by a genuine event (TimerIssuedCti). If I didn’t do this check then I would enqueue a Cti every time the timer elapsed which is not something I wanted. If the difference between the two times is greater than or equal to 500ms and the last event enqueued was by a real event then I issue a Cti through the timer to flush the event Queue, otherwise I do nothing. When I enqueue the Ctis into my stream in my ProduceEvents method I also set the values of dtCtiIssued and TimerIssuedCti   currEvent = CreateInsertEvent(); currEvent.StartTime = (DateTimeOffset)dt.c2; TimerIssuedCti = false; dtCtiIssued = currEvent.StartTime; If I go ahead and run this configuration I see the following in my output. As we can see the first Cti gets enqueued as before but then another is enqueued by the timer and because this has a later timestamp it flushes the enqueued events through the engine. Conclusion Hopefully this has shown how the enqueuing of Ctis can have a dramatic effect on the responsiveness of your output in StreamInsight. Understanding the temporal nature of the product is for me one of the most important things you can learn. I have attached my solution for the demos. It is all in one project and testing each variation is a simple matter of commenting and un-commenting the parts in the code we have been dealing with here.

    Read the article

  • Networking Problem MrxSmb event 50 "Delayed Write Failed" errors occurring all of the sudden

    - by Johnny Musso
    JUST THIS MONTH, we have started getting reports from a number of very stable clients that MrxSmb event id 50 errors keep appearing in their system event logs. Otherwise, they do not appear to have any networking problems except that there is a critical legacy application which seems to either be generating the MrxSmb errors or having errors occur because of them. The legacy application is comprised of 16 bit and 32 bit code and has not been changed or recompiled in many years. It has always been stable on Windows XP systems. The customers that have the problem usually have a small (5 clients or less) peer to peer network with all Windows XP systems. All service packs are loaded on the XP machines. Note: The only thing that seems to correct the problem is disabling opportunistic locking. I don't like this solution because it seems to slow down the network and sometimes causes record locking issues between users (on some networks). Also, this seems to have just started happening - as if a Windows update for XP has caused it? However, I have removed recent updates and it did not correct the issue. Thanks in advance for any help you can provide.

    Read the article

  • windows 7: Event 55 The file system structure on the disk is corrupt and unusable

    - by Radio
    Here is a real bad one! Windows 7 RTM with SP1 installed [Version 6.1.7601]. Recently tried to delete some folder on my hard drive and Windows prompted "Error 0x80070570: The file or directory is corrupted and unreadable", and at the same time placed an Event 55 describing "The file system structure on the disk is corrupt and unusable. Please run the chkdsk utility on \Device\HarddiskVolume2." Ran chkdsk, first with /f option, then with /r option. Result in both cases was: no errors found, 0 bad sectors. No problems chkdsk found at all! Went through StackExchange, Google and spent over 6 hours on this. Still cannot figure out the problem. Re-installing/Re-Formatting is not an option! What did I try: Hotfix - Windows6.1-KB982927-x64.msu - gave me an error about incompatibility with my computer, however it totally matches my system. CRC of hotfix was ok. Windows Repair Console found startup errors and fixed those, but this didn't help an issue, even by running chkdsk c: /R from it. http://support.microsoft.com/kb/246026 does not promise anything good. sfc /scannow does not help too. Replaced hard drive by cloning an old one using True Image, repeated all steps above. At the same time, some minor glitches started to appear in my Windows, like side panel and notification area settings are getting reset. Goal is to delete the folder and get rid of Event 55. Sounds like NTFS bug. Please help. This is completely ridiculous.

    Read the article

  • Office 2007 constantly crashes, logged as Event ID 1000

    - by Nori
    I have a user, who despite my best efforts, is having constant Office 2007 crashes. I've tried deleting their profile and setting it up again, repairing office, uninstalling completely and then reinstalling, and swapping out memory sticks. One event log error I keep getting is the following: (note all the Office errors are event id 1000) Faulting application name: OUTLOOK.EXE, version: 12.0.6539.5000, time stamp: 0x4c12486d Faulting module name: EMSMDB32.DLL, version: 12.0.6539.5000, time stamp: 0x4c1246f8 Exception code: 0xc0000005 Fault offset: 0x0005d8e2 Faulting process id: 0xf6c Faulting application start time: 0x01cb6633f33384f3 Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\OUTLOOK.EXE Faulting module path: c:\progra~2\micros~1\office12\EMSMDB32.DLL Report Id: 0d4a2eab-d231-11df-80a0-4061868f5d10 I also get this: Faulting application name: OUTLOOK.EXE, version: 12.0.6539.5000, time stamp: 0x4c12486d Faulting module name: olmapi32.dll, version: 12.0.6538.5000, time stamp: 0x4bfc6ad9 Exception code: 0xc0000005 Fault offset: 0x002357a9 Faulting process id: 0x5e4 Faulting application start time: 0x01cb661f4546aa77 Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\OUTLOOK.EXE Faulting module path: c:\progra~2\micros~1\office12\olmapi32.dll Report Id: a4a90658-d224-11df-80a0-4061868f5d10 The Excel error is this: Faulting application name: EXCEL.EXE, version: 12.0.6535.5002, time stamp: 0x4bd2a7f1 Faulting module name: KERNELBASE.dll, version: 6.1.7600.16385, time stamp: 0x4a5bdbdf Exception code: 0xe06d7363 Fault offset: 0x0000b727 Faulting process id: 0x14a8 Faulting application start time: 0x01cb61ab7bc0abab Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\EXCEL.EXE Faulting module path: C:\Windows\syswow64\KERNELBASE.dll Report Id: ba0c454b-cd9e-11df-80a0-4061868f5d10 Also have gotten this for PowerPoint: Faulting application name: POWERPNT.EXE, version: 12.0.6500.5000, time stamp: 0x49a68f9d Faulting module name: COMShim.dll, version: 2010.3.325.110, time stamp: 0x4c51e0b1 Exception code: 0x40000015 Fault offset: 0x0001e388 Faulting process id: 0x1480 Faulting application start time: 0x01cb5fe9a0660e81 Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\POWERPNT.EXE Faulting module path: C:\Program Files (x86)\FactSet\COMShim.dll Report Id: e03d2a21-cbdc-11df-9bc8-4061868f5d10 (Some of the above lines edited to keep you from scroll horizontally.) Lastly, I get this error several times a day, I don't think it is related but maybe it is: Failed extract of third-party root list from auto update cab at: http://www.download.windowsupdate.com/msdownload/update/v3/static/trustedr/en/authrootstl.cab with error: A required certificate is not within its validity period when verifying against the current system clock or the timestamp in the signed file. Any ideas? This is driving me nuts.

    Read the article

  • Deploying Windows Service through group policy fails with Event ID 102

    - by Sören Kuklau
    I'm trying to deploy a custom Windows Service (written in C#; installed through a VS setup project) using a group policy. To help debug this, I also have two additional MSIs in the same policy. All three packages are deployed as a machine policy, not a user one. On one machine (runs Windows Server 2008; no UAC), all three deploy fine. The service is set to Automatic, as expected. On two machines (run Windows 7; UAC), the two other MSIs deploy fine, but my service fails to install. The event log gives an event ID of 102, which appears to be a permissions problem: The install of application "Package Name" from policy "Policy Name" failed. The error was The installation source for this product is not available. Verify that the source exists and that you can access it. However, all three packages come from the same share linked through UNC, so this is unlikely. My guess is that UAC is the problem; that the service requires additional permissions. Do I need to alter the MSI somehow?

    Read the article

  • UACCEEventLog 301 Filling Event Logs

    - by rjt
    After pushing out clients for the MS Application Compatibility Toolkit on our domain via GPO, UACCEEventLog 301 occurs a few times per second in the event log. Several Thousand per hour. One test i need to do is logon with Administrator to see if these events go away while Admin, but of course that is not a fix. This is only part of the event log entry, but is the most readable and clearly indicates yet another problem with Antivirus software. But still no fix. Originally, i posted this In Words and Bytes, but then edited it to make it much easier to read. LocalMachine\Users do have Read Access to this key. For a test, i added "Domain Users" but there are many more events for other parts of the registry and for Administrators. <XML> <TYPE> UacceRegistryVirtualization </TYPE> <EXENAME>smcgui.exe</EXENAME> <EXEPATH>c:\program files\symantec\symantec endpoint protection </EXEPATH> <APINAME>RegOpenKeyA</APINAME> <REGKEYNAME> HKEY_LOCAL_MACHINE\SOFTWARE \Symantec\Symantec Endpoint Protection\AV\Storages \SymHeurProcessProtection\RealTimeScan\0 </REGKEYNAME> <RESTRICTEDBYACL>FALSE</RESTRICTEDBYACL> <DESIREDACCESS>MAXIMUM_ALLOWED</DESIREDACCESS> <REGVALUENAME></REGVALUENAME> <REGVALUETYPE>0x00000000</REGVALUETYPE> <REGVALUEDATA></REGVALUEDATA> <CURRENTGROUP>Users</CURRENTGROUP> </XML>

    Read the article

  • zsh auto-complete event designator

    - by simont
    (See my previous question for additional context). I'm migrating to zsh from bash, and using oh-my-zsh. When my zsh history looks something like the following: git status git add -A git commit I want to be able to re-run git add -A. To do that, I could use !?git add, which should: !?str[?] Refer to the most recent command containing str. The trailing ‘?’ is necessary if this reference is to be followed by a modifier or followed by any text that is not to be considered part of str. The link for zsh event designators is here. Unfortunately, I can't do this - as I'm typing !?git add, as I hit the ' ', it auto-completes the command to the most recent command matching git (ie, it auto-completes with git commit). I can't use the event designator properly because of this auto-completion as I hit the space. I assume this is an oh-my-zsh feature. I have no idea where to look, though - greping for 'complet' in the oh-my-zsh source doesn't get me anywhere. My question: how do I turn off this feature? Or, if that's not something that's known, where should I be looking - if I was going to implement this auto-complete when whitespace is entered, where would be a logical place to do so in the oh-my-zsh framework?

    Read the article

  • Diagnosing Logon Audit Failure event log entries

    - by Scott Mitchell
    I help a client manage a website that is run on a dedicated web server at a hosting company. Recently, we noticed that over the last two weeks there have been tens of thousands of Audit Failure entries in the Security Event Log with Task Category of Logon - these have been coming in about every two seconds, but interesting stopped altogether as of two days ago. In general, the event description looks like the following: An account failed to log on. Subject: Security ID: SYSTEM Account Name: ...The Hosting Account... Account Domain: ...The Domain... Logon ID: 0x3e7 Logon Type: 10 Account For Which Logon Failed: Security ID: NULL SID Account Name: david Account Domain: ...The Domain... Failure Information: Failure Reason: Unknown user name or bad password. Status: 0xc000006d Sub Status: 0xc0000064 Process Information: Caller Process ID: 0x154c Caller Process Name: C:\Windows\System32\winlogon.exe Network Information: Workstation Name: ...The Domain... Source Network Address: 173.231.24.18 Source Port: 1605 The value in the Account Name field differs. Above you see "david" but there are ones with "john", "console", "sys", and even ones like "support83423" and whatnot. The Logon Type field indicates that the logon attempt was a remote interactive attempt via Terminal Services or Remote Desktop. My presumption is that these are some brute force attacks attempting to guess username/password combinations in order to log into our dedicated server. Are these presumptions correct? Are these types of attacks pretty common? Is there a way to help stop these types of attacks? We need to be able to access the desktop via Remote Desktop so simply turning off that service is not feasible. Thanks

    Read the article

  • returning correct multiTouch id

    - by Max
    I've spent countless hours on reading tutorials and looking at every question related to multiTouch from here and Stackoverflow. But I just cannot figure out how to do this correctly. I use a loop to get my pointerId, I dont see alot of people doing this but its the only way I've managed to get it somewhat working. I have two joysticks on my screen, one for moving and one for controlling my sprites rotation and the angle he shoots, like in Monster Shooter. Both these work fine. My problem is that when I Move my sprite at the same time as Im shooting, my touchingPoint for my movement is set to the touchingPoint of my shooting, since the x and y is higher on the touchingPoint of my shooting (moving-stick on left side of screen, shooting-stick on right side), my sprite speeds up, this creates an unwanted change in speed for my sprite. I will post my entire onTouch method here with some variable-changes to make it more understandable. Since I do not know where Im going wrong. public void update(MotionEvent event) { if (event == null && lastEvent == null) { return; } else if (event == null && lastEvent != null) { event = lastEvent; } else { lastEvent = event; } int pointerCount = event.getPointerCount(); for (int i = 0; i < pointerCount; i++) { int x = (int) event.getX(i); int y = (int) event.getY(i); int id = event.getPointerId(i); int action = event.getActionMasked(); int actionIndex = event.getActionIndex(); String actionString; switch (action) { case MotionEvent.ACTION_DOWN: actionString = "DOWN"; break; case MotionEvent.ACTION_UP: shooting=false; // when shooting is true, it shoots dragging=false; // when dragging is true, it moves actionString = "UP"; break; case MotionEvent.ACTION_POINTER_DOWN: actionString = "PNTR DOWN"; break; case MotionEvent.ACTION_POINTER_UP: shooting=false; dragging=false; actionString = "PNTR UP"; break; case MotionEvent.ACTION_CANCEL: shooting=false; dragging=false; actionString = "CANCEL"; break; case MotionEvent.ACTION_MOVE: try{ if((int) event.getX(id) > 0 && (int) event.getX(id) < touchingBox && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ movingPoint.x = (int) event.getX(id); movingPoint.y = (int) event.getY(id); dragging = true; } else if((int) event.getX(id) > touchingBox && (int) event.getX(id) < view.getWidth() && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ shootingPoint.x = (int) event.getX(id); shootingPoint.y = (int) event.getY(id); shooting=true; }else{ shooting=false; dragging=false; } }catch(Exception e){ } actionString = "MOVE"; break; default: actionString = ""; } Wouldnt post this much code if I wasnt at an absolute loss of what I'm doing wrong. I simply can not get a good understanding of how multiTouching works. basicly movingPoint changes for both my first and second finger. I bind it to a box, but aslong as I hold one finger within this box, it changes its value based on where my second finger touches. It moves in the right direction and nothing gives an error, the problem is the speed-change, its almost like it adds up the two touchingPoints.

    Read the article

  • Norton Ghost EBAB03F1: The specified network name is no longer available.

    - by Breck Carter
    After about 15 minutes, a Norton Ghost 14 backup fails with Error EBAB03F1: The specified network name is no longer available. The source computer is a P4 laptop running Windows XP SP3. The target computer is a Core2 Quad desktop running Windows Vista Ultimate 64bit. It does not help to disable Norton 360 on the source computer or Norton Antivirus 2008 on the target computer. The Event Viewer consistently shows the same two VSS-related errors after Norton Ghost starts but before it fails. It makes no difference if the VSS service is started or stopped. The VSS errors do not appear elsewhere in the event log, only after Ghost starts. The MSS event messages, however, are quite common, appearing throughout the log, and they may have nothing to do with the problem. Here is the Norton Ghost error display... -Errors exist. --Unable to write to file. ---Error EBAB03F1: The specified network name is no longer available. ---Unable to set file size. ----Error EBAB03F1: The specified network name is no longer available. ----Unable to write to file. -----Error EBAB03F1: The specified network name is no longer available. -----Unable to set file size. ------Error EBAB03F1: The specified network name is no longer available. Here are the source computer events, with the final error at the top and the "Ghost Starting" message at the bottom: ===== Event Type: Error Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:40:26 AM User: N/A Computer: PAVILION2 Description: Error EC8F17B7: Cannot create recovery points for job: Drive Backup of (C:\) (3). Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Details: 0xEBAB0005 Source: Norton Ghost ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 3421 Date: 11/09/2009 Time: 9:34:06 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Recovery completed for database ReportServer$SQLEXPRESSTempDB (database ID 6) in 1 second(s) (analysis 205 ms, redo 0 ms, undo 376 ms.) This is an informational message only. No user action is required. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 5d 0d 00 00 0a 00 00 00 ]....... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 17137 Date: 11/09/2009 Time: 9:34:02 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Starting up database 'ReportServer$SQLEXPRESSTempDB'. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: f1 42 00 00 0a 00 00 00 ñB...... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 12302 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: An internal inconsistency was detected in trying to contact shadow copy service writers. Please check to see that the Event Service and Volume Shadow Copy Service are operating properly. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 42 55 45 43 58 4d 4c 43 BUECXMLC 0008: 33 36 33 37 00 00 00 00 3637.... 0010: 42 55 45 43 58 4d 4c 43 BUECXMLC 0018: 33 36 30 37 00 00 00 00 3607.... ===== Event Type: Information Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:27:57 AM User: N/A Computer: PAVILION2 Description: Info 6C8F1F63: The drive-based backup job, Drive Backup of (C:\) (3), has been started manually. Details: Source: Norton Ghost

    Read the article

  • Norton Ghost EBAB03F1: The specified network name is no longer available

    - by Breck Carter
    After about 15 minutes, a Norton Ghost 14 backup fails with Error EBAB03F1: The specified network name is no longer available. The source computer is a P4 laptop running Windows XP SP3. The target computer is a Core2 Quad desktop running Windows Vista Ultimate 64bit. It does not help to disable Norton 360 on the source computer or Norton Antivirus 2008 on the target computer. The Event Viewer consistently shows the same two VSS-related errors after Norton Ghost starts but before it fails. It makes no difference if the VSS service is started or stopped. The VSS errors do not appear elsewhere in the event log, only after Ghost starts. The MSS event messages, however, are quite common, appearing throughout the log, and they may have nothing to do with the problem. Here is the Norton Ghost error display... -Errors exist. --Unable to write to file. ---Error EBAB03F1: The specified network name is no longer available. ---Unable to set file size. ----Error EBAB03F1: The specified network name is no longer available. ----Unable to write to file. -----Error EBAB03F1: The specified network name is no longer available. -----Unable to set file size. ------Error EBAB03F1: The specified network name is no longer available. Here are the source computer events, with the final error at the top and the "Ghost Starting" message at the bottom: ===== Event Type: Error Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:40:26 AM User: N/A Computer: PAVILION2 Description: Error EC8F17B7: Cannot create recovery points for job: Drive Backup of (C:\) (3). Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Details: 0xEBAB0005 Source: Norton Ghost ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 3421 Date: 11/09/2009 Time: 9:34:06 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Recovery completed for database ReportServer$SQLEXPRESSTempDB (database ID 6) in 1 second(s) (analysis 205 ms, redo 0 ms, undo 376 ms.) This is an informational message only. No user action is required. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 5d 0d 00 00 0a 00 00 00 ]....... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 17137 Date: 11/09/2009 Time: 9:34:02 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Starting up database 'ReportServer$SQLEXPRESSTempDB'. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: f1 42 00 00 0a 00 00 00 ñB...... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 12302 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: An internal inconsistency was detected in trying to contact shadow copy service writers. Please check to see that the Event Service and Volume Shadow Copy Service are operating properly. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 42 55 45 43 58 4d 4c 43 BUECXMLC 0008: 33 36 33 37 00 00 00 00 3637.... 0010: 42 55 45 43 58 4d 4c 43 BUECXMLC 0018: 33 36 30 37 00 00 00 00 3607.... ===== Event Type: Information Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:27:57 AM User: N/A Computer: PAVILION2 Description: Info 6C8F1F63: The drive-based backup job, Drive Backup of (C:\) (3), has been started manually. Details: Source: Norton Ghost

    Read the article

  • .NET SerialPort DataReceived event not firing

    - by Klay
    I have a WPF test app for evaluating event-based serial port communication (vs. polling the serial port). The problem is that the DataReceived event doesn't seem to be firing at all. I have a very basic WPF form with a TextBox for user input, a TextBlock for output, and a button to write the input to the serial port. Here's the code: public partial class Window1 : Window { SerialPort port; public Window1() { InitializeComponent(); port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); } void port_DataReceived(object sender, SerialDataReceivedEventArgs e) { Debug.Print("receiving!"); string data = port.ReadExisting(); Debug.Print(data); outputText.Text = data; } private void Button_Click(object sender, RoutedEventArgs e) { Debug.Print("sending: " + inputText.Text); port.WriteLine(inputText.Text); } } Now, here are the complicating factors: The laptop I'm working on has no serial ports, so I'm using a piece of software called Virtual Serial Port Emulator to setup a COM2. VSPE has worked admirably in the past, and it's not clear why it would only malfunction with .NET's SerialPort class, but I mention it just in case. When I hit the button on my form to send the data, my Hyperterminal window (connected on COM2) shows that the data is getting through. Yes, I disconnect Hyperterminal when I want to test my form's ability to read the port. I've tried opening the port before wiring up the event. No change. I've read through another post here where someone else is having a similar problem. None of that info has helped me in this case. EDIT: Here's the console version (modified from http://mark.michaelis.net/Blog/TheBasicsOfSystemIOPortsSerialPort.aspx): class Program { static SerialPort port; static void Main(string[] args) { port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); string text; do { text = Console.ReadLine(); port.Write(text + "\r\n"); } while (text.ToLower() != "q"); } public static void port_DataReceived(object sender, SerialDataReceivedEventArgs args) { string text = port.ReadExisting(); Console.WriteLine("received: " + text); } } This should eliminate any concern that it's a Threading issue (I think). This doesn't work either. Again, Hyperterminal reports the data sent through the port, but the console app doesn't seem to fire the DataReceived event. EDIT #2: I realized that I had two separate apps that should both send and receive from the serial port, so I decided to try running them simultaneously... If I type into the console app, the WPF app DataReceived event fires, with the expected threading error (which I know how to deal with). If I type into the WPF app, the console app DataReceived event fires, and it echoes the data. I'm guessing the issue is somewhere in my use of the VSPE software, which is set up to treat one serial port as both input and output. And through some weirdness of the SerialPort class, one instance of a serial port can't be both the sender and receiver. Anyway, I think it's solved.

    Read the article

  • event capturing or bubbling

    - by ChampionChris
    I have a link button in a repeater control. the li element is drag and droppable using jquery. when the page loads the the link button works perfectly, the jquery that is attached and the server side code both execute. when I perform a drag and drop then click on the link button it doesn't not fire. when i click it a second time it does fire. If i perform 2 or drag and drops in a row the link button doesn't fire a as many drag and drops as i before it will fire. for example if if perform 3 drag and drops then it will take about 3 click before the events are fired. <asp:Repeater ID="rTracks" runat="server" OnItemDataBound="rTracks_ItemDataBound" EnableViewState="true"> <ItemTemplate> <li onclick="testclick();" class='admin-song ui-selectee <asp:Literal id="ltStatusClass" runat="server" />' mediaid="<%# Eval("MediaId") %>" artistid="<%# Eval("tbMedia.tbArtists.id") %>"><span class="handle"><strong> <%--<%# int.Parse(DataBinder.Eval(Container, "ItemIndex", "")) + 1%>--%><%# Eval("SortNumber")%></strong><%--0:03--%></span> <span class="play"><span class="btn-play">&nbsp;</span></span> <span class="track" title="<%# Eval("tbMedia.Title") %>"> <%# Eval("tbMedia.Title") %></span> <span class="artist"> <%# Eval("tbMedia.tbArtists.Name") %></span> <span class="time" length="<%# Eval("tbMedia.Length") %>"> <asp:Literal ID="ltRuntime" runat="server" /></span> <span class="notes"><span class="btn-notes"> <asp:Literal ID="ltNotesCount" runat="server" /></span></span> <span class="status"> <asp:Literal ID="ltStatus" runat="server" /></span> <span class="date"> <%# Eval("DateAdded") %></span> <span class="remove"><asp:LinkButton ID="lbStatusClass2" runat="server" CssClass="btn-del" OnClick="UpdateStatus" ValidationGroup='<%#Bind("MediaId") %>'> <%--<span class='<asp:Literal id="ltStatusClass2" runat="server" Text="btn-del" />'>--%> &nbsp;<%--</span>--%></asp:LinkButton></span></span> </li> </ItemTemplate> </asp:Repeater> I have onclick event on the li element, when the mouse is clicks the link button the li onclick event is fired even when linkbutton event doesnt fire. My question is if the li captures the event y doesnt the event fire on the linkbutton? What would be stopping the event?

    Read the article

  • DNS Client Event 1012: Error reading local hosts file

    - by Sam
    My notebook boots extreme slowly and shows loads of the following error in the event log: Error reading local hosts file Source: DNS Client Events EventID: 1012 The computer is quite new, I kind of just finished installing. So I don't feel like installing everything again (especially since this probably would result in the same problem anyway). Any idea how to resolve this? Thanks, Sam

    Read the article

  • Remote Desktop event ID 20499. No noticeable issues

    - by Marc05
    I get a warning event with ID 20499 for TerminalServices-RemoteConnectionManager.The error is: Remote Desktop Services has taken too long to load the user configuration from server \server.domain.home for user administrator. Yet, I don't see any issues (I'm guessing because that user is on the machine local). Why am I getting this warning? I'm on Windows Server 2012 R2 connecting from a Windows 8.1.

    Read the article

< Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >