Search Results

Search found 20859 results on 835 pages for 'little bobby tables'.

Page 76/835 | < Previous Page | 72 73 74 75 76 77 78 79 80 81 82 83  | Next Page >

  • How to select the top n from a union of two queries where the resulting order needs to be ranked by individual query?

    - by Jedidja
    Let's say I have a table with usernames: Id | Name ----------- 1 | Bobby 20 | Bob 90 | Bob 100 | Joe-Bob 630 | Bobberino 820 | Bob Junior I want to return a list of n matches on name for 'Bob' where the resulting set first contains exact matches followed by similar matches. I thought something like this might work SELECT TOP 4 a.* FROM ( SELECT * from Usernames WHERE Name = 'Bob' UNION SELECT * from Usernames WHERE Name LIKE '%Bob%' ) AS a but there are two problems: It's an inefficient query since the sub-select could return many rows (looking at the execution plan shows a join happening before top) (Almost) more importantly, the exact match(es) will not appear first in the results since the resulting set appears to be ordered by primary key. I am looking for a query that will return (for TOP 4) Id | Name --------- 20 | Bob 90 | Bob (and then 2 results from the LIKE query, e.g. 1 Bobby and 100 Joe-Bob) Is this possible in a single query?

    Read the article

  • Better way to make a bash script self-tracing?

    - by Kevin Little
    I have certain critical bash scripts that are invoked by code I don't control, and where I can't see their console output. I want a complete trace of what these scripts did for later analysis. To do this I want to make each script self-tracing. Here is what I am currently doing: #!/bin/bash # if last arg is not '_worker_', relaunch with stdout and stderr # redirected to my log file... if [[ "$BASH_ARGV" != "_worker_" ]]; then $0 "$@" _worker_ >>/some_log_file 2>&1 # add tee if console output wanted exit $? fi # rest of script follows... Is there a better, cleaner way to do this?

    Read the article

  • Can a page opt out of IIS 7 compression?

    - by Glen Little
    My pages are automatically being compressed by IIS7 with GZIP. That is great... but, for one particular page, I need to stream it to the user, using Response.Flush() when needed. But when the output is being compressed, the IIS server seems to collect all my output until the page is done before compressing and sending it to the client. That nullifies my attempt to Flush the content out to the user. Is there a way that I can have this one page opt out of the compression? One possible option I've determined that if I manually set the content type to one that does not match the IIS configuration at c:\windows\system32\inetsrv\config\applicationhost.config, then IIS will not compress it. Eg. Response.ContentType = "x-text/html". This works okay with IE8, as it falls back to display the HTML. But Firefox will ask the user what to do with the unknown file type. This could work, if there was another Mime Type I could use that browsers would accept as HTML, that is not matched in the applicationhost.config. For reference, these are the mime types that will be compressed: <add mimeType="text/*" enabled="true" /> <add mimeType="message/*" enabled="true" /> <add mimeType="application/x-javascript" enabled="true" /> <add mimeType="application/atom+xml" enabled="true" /> <add mimeType="application/xaml+xml" enabled="true" /> Others options? Are there other options to opt out of compression?

    Read the article

  • Issue with Callback method and maintaining CultureInfo and ASP.Net HttpRuntime

    - by Little Larry Sellers
    Hi All, Here is my issue. I am working on an E-commerce solution that is deployed to multiple European countries. We persist all exceptions within the application to SQL Server and I have found that there are records in the DB that have a DateTime in the future! We define the culture in the web.config, for example pt-PT, and the format expected is DD-MM-YYYY. After debugging I found the issue with these 'future' records in the DB is because of Callback methods we use. For example, in our Caching architecture we use Callbacks, as such - CacheItemRemovedCallback ReloadCallBack = new CacheItemRemovedCallback(OnRefreshRequest); When I check the current threads CultureInfo, on these Callbacks it is en-US instead of pt-PT and also the HttpContext is null. If an exception occurs on the Callback our exception manager reports it as MM-DD-YYYY and thus it is persisted to SQL Server incorrectly. Unfortunately, in the exception manager code, we use DateTime.Now, which is fine if it is not a callback. I can't change this code to be culture specific due to it being shared across other verticals. So, why don't callbacks into ASP.Net maintain context? Is there any way to maintain it on this callback thread? What are the best practices here? Thanks.

    Read the article

  • Writing a managed wrapper for unmanaged (C++) code - custom types/structs

    - by Bobby
    faacEncConfigurationPtr FAACAPI faacEncGetCurrentConfiguration( faacEncHandle hEncoder); I'm trying to come up with a simple wrapper for this C++ library; I've never done more than very simple p/invoke interop before - like one function call with primitive arguments. So, given the above C++ function, for example, what should I do to deal with the return type, and parameter? FAACAPI is defined as: #define FAACAPI __stdcall faacEncConfigurationPtr is defined: typedef struct faacEncConfiguration { int version; char *name; char *copyright; unsigned int mpegVersion; unsigned long bitRate; unsigned int inputFormat; int shortctl; psymodellist_t *psymodellist; int channel_map[64]; } faacEncConfiguration, *faacEncConfigurationPtr; AFAIK this means that the return type of the function is a reference to this struct? And faacEncHandle is: typedef struct { unsigned int numChannels; unsigned long sampleRate; ... SR_INFO *srInfo; double *sampleBuff[MAX_CHANNELS]; ... double *freqBuff[MAX_CHANNELS]; double *overlapBuff[MAX_CHANNELS]; double *msSpectrum[MAX_CHANNELS]; CoderInfo coderInfo[MAX_CHANNELS]; ChannelInfo channelInfo[MAX_CHANNELS]; PsyInfo psyInfo[MAX_CHANNELS]; GlobalPsyInfo gpsyInfo; faacEncConfiguration config; psymodel_t *psymodel; /* quantizer specific config */ AACQuantCfg aacquantCfg; /* FFT Tables */ FFT_Tables fft_tables; int bitDiff; } faacEncStruct, *faacEncHandle; So within that struct we see a lot of other types... hmm. Essentially, I'm trying to figure out how to deal with these types in my managed wrapper? Do I need to create versions of these types/structs, in C#? Something like this: [StructLayout(LayoutKind.Sequential)] struct faacEncConfiguration { uint useTns; ulong bitRate; ... } If so then can the runtime automatically "map" these objects onto eachother? And, would I have to create these "mapped" types for all the types in these return types/parameter type hierarchies, all the way down until I get to all primitives? I know this is a broad topic, any advice on getting up-to-speed quickly on what I need to learn to make this happen would be very much appreciated! Thanks!

    Read the article

  • Saving an xml file without

    - by little
    Hi, How do I work with an xml file that when updating it, after saving the commented lines would still be present. Here's my code snippet for saving the file: public static void WriteSettings(Settings settings, string path) { XmlSerializer serializer = new XmlSerializer(typeof(Settings)); TextWriter writer = new StreamWriter(path); serializer.Serialize(writer, settings); writer.Close(); }

    Read the article

  • Processing an XML file removes comments

    - by little
    This snippet <!--Please don't delete this--> is part of my xml file. After running this method, the resulting xml file does not contain this snippet anymore <!--Please don't delete this-->. Why is this? Here's my method: XmlSerializer serializer = new XmlSerializer(typeof(Settings)); TextWriter writer = new StreamWriter(path); serializer.Serialize(writer, settings); writer.Close();

    Read the article

  • Please help with very simple android widget button click. Getting very frustrated. :(

    - by Little Wendy
    I have poured over every example that I can find and I have gone through the official documentation from google. All I am trying to do is create a toast notification from a button click on a widget. I can get the widget (and button) to appear but I can't get my intent to fire. I have seen several examples that show doing this different ways but I just can't get it to work. I haven't felt this helpless with coding in a long time and I'm starting to feel dumb. This is what I have so far: public class simpleclick extends AppWidgetProvider { /** Called when the activity is first created. */ @Override public void onUpdate(Context context, AppWidgetManager appWidgetManager, int[] appWidgetIds) { final int N = appWidgetIds.length; Toast.makeText(context, "doing on update", Toast.LENGTH_SHORT).show(); for (int i=0; i<N; i++) { int appWidgetId = appWidgetIds[i]; Intent intent = new Intent(context, simpleclick.class); intent.setAction("ham"); PendingIntent pendingIntent = PendingIntent.getActivity(context, 0, intent, 0); RemoteViews views = new RemoteViews(context.getPackageName(), R.layout.main); views.setOnClickPendingIntent(R.id.Timm, pendingIntent); appWidgetManager.updateAppWidget(appWidgetId, views); } } //@Override public void onReceive(Context context, Intent intent) { // TODO Auto-generated method stub Toast.makeText(context, "action is: " + intent.getAction(), Toast.LENGTH_SHORT).show(); super.onReceive(context, intent); } } My manifest: <?xml version="1.0" encoding="utf-8"?> <manifest xmlns:android="http://schemas.android.com/apk/res/android" package="com.tblabs.simpleclick" android:versionCode="1" android:versionName="1.0"> <application android:icon="@drawable/icon" android:label="@string/app_name"> <receiver android:name="simpleclick"> <intent-filter> <action android:name="android.appwidget.action.APPWIDGET_UPDATE" /> </intent-filter> <meta-data android:name="android.appwidget.provider" android:resource="@xml/simpleclick" /> </receiver> </application> <uses-sdk android:minSdkVersion="5" /> </manifest> I would appreciate some help! Thanks, Wendy

    Read the article

  • SQL Monitor’s data repository: Alerts

    - by Chris Lambrou
    In my previous post, I introduced the SQL Monitor data repository, and described how the monitored objects are stored in a hierarchy in the data schema, in a series of tables with a _Keys suffix. In this post I had planned to describe how the actual data for the monitored objects is stored in corresponding tables with _StableSamples and _UnstableSamples suffixes. However, I’m going to postpone that until my next post, as I’ve had a request from a SQL Monitor user to explain how alerts are stored. In the SQL Monitor data repository, alerts are stored in tables belonging to the alert schema, which contains the following five tables: alert.Alert alert.Alert_Cleared alert.Alert_Comment alert.Alert_Severity alert.Alert_Type In this post, I’m only going to cover the alert.Alert and alert.Alert_Type tables. I may cover the other three tables in a later post. The most important table in this schema is alert.Alert, as each row in this table corresponds to a single alert. So let’s have a look at it. SELECT TOP 100 AlertId, AlertType, TargetObject, [Read], SubType FROM alert.Alert ORDER BY AlertId DESC;  AlertIdAlertTypeTargetObjectReadSubType 165550397:Cluster,1,4:Name,s29:srp-mr03.testnet.red-gate.com,9:SqlServer,1,4:Name,s0:,10 265549387:Cluster,1,4:Name,s29:srp-mr03.testnet.red-gate.com,7:Machine,1,4:Name,s0:,10 365548187:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s15:FavouriteThings,00 465547157:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s15:FavouriteThings,00 565546147:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s15:FavouriteThings,00 665545187:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,00 765544157:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,00 865543147:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,00 965542187:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s4:msdb,00 1065541147:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s4:msdb,00 11…     So what are we seeing here, then? Well, AlertId is an auto-incrementing identity column, so ORDER BY AlertId DESC ensures that we see the most recent alerts first. AlertType indicates the type of each alert, such as Job failed (6), Backup overdue (14) or Long-running query (12). The TargetObject column indicates which monitored object the alert is associated with. The Read column acts as a flag to indicate whether or not the alert has been read. And finally the SubType column is used in the case of a Custom metric (40) alert, to indicate which custom metric the alert pertains to. Okay, now lets look at some of those columns in more detail. The AlertType column is an easy one to start with, and it brings use nicely to the next table, data.Alert_Type. Let’s have a look at what’s in this table: SELECT AlertType, Event, Monitoring, Name, Description FROM alert.Alert_Type ORDER BY AlertType;  AlertTypeEventMonitoringNameDescription 1100Processor utilizationProcessor utilization (CPU) on a host machine stays above a threshold percentage for longer than a specified duration 2210SQL Server error log entryAn error is written to the SQL Server error log with a severity level above a specified value. 3310Cluster failoverThe active cluster node fails, causing the SQL Server instance to switch nodes. 4410DeadlockSQL deadlock occurs. 5500Processor under-utilizationProcessor utilization (CPU) on a host machine remains below a threshold percentage for longer than a specified duration 6610Job failedA job does not complete successfully (the job returns an error code). 7700Machine unreachableHost machine (Windows server) cannot be contacted on the network. 8800SQL Server instance unreachableThe SQL Server instance is not running or cannot be contacted on the network. 9900Disk spaceDisk space used on a logical disk drive is above a defined threshold for longer than a specified duration. 101000Physical memoryPhysical memory (RAM) used on the host machine stays above a threshold percentage for longer than a specified duration. 111100Blocked processSQL process is blocked for longer than a specified duration. 121200Long-running queryA SQL query runs for longer than a specified duration. 131400Backup overdueNo full backup exists, or the last full backup is older than a specified time. 141500Log backup overdueNo log backup exists, or the last log backup is older than a specified time. 151600Database unavailableDatabase changes from Online to any other state. 161700Page verificationTorn Page Detection or Page Checksum is not enabled for a database. 171800Integrity check overdueNo entry for an integrity check (DBCC DBINFO returns no date for dbi_dbccLastKnownGood field), or the last check is older than a specified time. 181900Fragmented indexesFragmentation level of one or more indexes is above a threshold percentage. 192400Job duration unusualThe duration of a SQL job duration deviates from its baseline duration by more than a threshold percentage. 202501Clock skewSystem clock time on the Base Monitor computer differs from the system clock time on a monitored SQL Server host machine by a specified number of seconds. 212700SQL Server Agent Service statusThe SQL Server Agent Service status matches the status specified. 222800SQL Server Reporting Service statusThe SQL Server Reporting Service status matches the status specified. 232900SQL Server Full Text Search Service statusThe SQL Server Full Text Search Service status matches the status specified. 243000SQL Server Analysis Service statusThe SQL Server Analysis Service status matches the status specified. 253100SQL Server Integration Service statusThe SQL Server Integration Service status matches the status specified. 263300SQL Server Browser Service statusThe SQL Server Browser Service status matches the status specified. 273400SQL Server VSS Writer Service statusThe SQL Server VSS Writer status matches the status specified. 283501Deadlock trace flag disabledThe monitored SQL Server’s trace flag cannot be enabled. 293600Monitoring stopped (host machine credentials)SQL Monitor cannot contact the host machine because authentication failed. 303700Monitoring stopped (SQL Server credentials)SQL Monitor cannot contact the SQL Server instance because authentication failed. 313800Monitoring error (host machine data collection)SQL Monitor cannot collect data from the host machine. 323900Monitoring error (SQL Server data collection)SQL Monitor cannot collect data from the SQL Server instance. 334000Custom metricThe custom metric value has passed an alert threshold. 344100Custom metric collection errorSQL Monitor cannot collect custom metric data from the target object. Basically, alert.Alert_Type is just a big reference table containing information about the 34 different alert types supported by SQL Monitor (note that the largest id is 41, not 34 – some alert types have been retired since SQL Monitor was first developed). The Name and Description columns are self evident, and I’m going to skip over the Event and Monitoring columns as they’re not very interesting. The AlertId column is the primary key, and is referenced by AlertId in the alert.Alert table. As such, we can rewrite our earlier query to join these two tables, in order to provide a more readable view of the alerts: SELECT TOP 100 AlertId, Name, TargetObject, [Read], SubType FROM alert.Alert a JOIN alert.Alert_Type at ON a.AlertType = at.AlertType ORDER BY AlertId DESC;  AlertIdNameTargetObjectReadSubType 165550Monitoring error (SQL Server data collection)7:Cluster,1,4:Name,s29:srp-mr03.testnet.red-gate.com,9:SqlServer,1,4:Name,s0:,00 265549Monitoring error (host machine data collection)7:Cluster,1,4:Name,s29:srp-mr03.testnet.red-gate.com,7:Machine,1,4:Name,s0:,00 365548Integrity check overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s15:FavouriteThings,00 465547Log backup overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s15:FavouriteThings,00 565546Backup overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s15:FavouriteThings,00 665545Integrity check overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,00 765544Log backup overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,00 865543Backup overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,00 965542Integrity check overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s4:msdb,00 1065541Backup overdue7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s4:msdb,00 Okay, the next column to discuss in the alert.Alert table is TargetObject. Oh boy, this one’s a bit tricky! The TargetObject of an alert is a serialized string representation of the position in the monitored object hierarchy of the object to which the alert pertains. The serialization format is somewhat convenient for parsing in the C# source code of SQL Monitor, and has some helpful characteristics, but it’s probably very awkward to manipulate in T-SQL. I could document the serialization format here, but it would be very dry reading, so perhaps it’s best to consider an example from the table above. Have a look at the alert with an AlertID of 65543. It’s a Backup overdue alert for the SqlMonitorData database running on the default instance of granger, my laptop. Each different alert type is associated with a specific type of monitored object in the object hierarchy (I described the hierarchy in my previous post). The Backup overdue alert is associated with databases, whose position in the object hierarchy is root → Cluster → SqlServer → Database. The TargetObject value identifies the target object by specifying the key properties at each level in the hierarchy, thus: Cluster: Name = "granger" SqlServer: Name = "" (an empty string, denoting the default instance) Database: Name = "SqlMonitorData" Well, look at the actual TargetObject value for this alert: "7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s14:SqlMonitorData,". It is indeed composed of three parts, one for each level in the hierarchy: Cluster: "7:Cluster,1,4:Name,s7:granger," SqlServer: "9:SqlServer,1,4:Name,s0:," Database: "8:Database,1,4:Name,s14:SqlMonitorData," Each part is handled in exactly the same way, so let’s concentrate on the first part, "7:Cluster,1,4:Name,s7:granger,". It comprises the following: "7:Cluster," – This identifies the level in the hierarchy. "1," – This indicates how many different key properties there are to uniquely identify a cluster (we saw in my last post that each cluster is identified by a single property, its Name). "4:Name,s14:SqlMonitorData," – This represents the Name property, and its corresponding value, SqlMonitorData. It’s split up like this: "4:Name," – Indicates the name of the key property. "s" – Indicates the type of the key property, in this case, it’s a string. "14:SqlMonitorData," – Indicates the value of the property. At this point, you might be wondering about the format of some of these strings. Why is the string "Cluster" stored as "7:Cluster,"? Well an encoding scheme is used, which consists of the following: "7" – This is the length of the string "Cluster" ":" – This is a delimiter between the length of the string and the actual string’s contents. "Cluster" – This is the string itself. 7 characters. "," – This is a final terminating character that indicates the end of the encoded string. You can see that "4:Name,", "8:Database," and "14:SqlMonitorData," also conform to the same encoding scheme. In the example above, the "s" character is used to indicate that the value of the Name property is a string. If you explore the TargetObject property of alerts in your own SQL Monitor data repository, you might find other characters used for other non-string key property values. The different value types you might possibly encounter are as follows: "I" – Denotes a bigint value. For example, "I65432,". "g" – Denotes a GUID value. For example, "g32116732-63ae-4ab5-bd34-7dfdfb084c18,". "d" – Denotes a datetime value. For example, "d634815384796832438,". The value is stored as a bigint, rather than a native SQL datetime value. I’ll describe how datetime values are handled in the SQL Monitor data repostory in a future post. I suggest you have a look at the alerts in your own SQL Monitor data repository for further examples, so you can see how the TargetObject values are composed for each of the different types of alert. Let me give one further example, though, that represents a Custom metric alert, as this will help in describing the final column of interest in the alert.Alert table, SubType. Let me show you the alert I’m interested in: SELECT AlertId, a.AlertType, Name, TargetObject, [Read], SubType FROM alert.Alert a JOIN alert.Alert_Type at ON a.AlertType = at.AlertType WHERE AlertId = 65769;  AlertIdAlertTypeNameTargetObjectReadSubType 16576940Custom metric7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s6:master,12:CustomMetric,1,8:MetricId,I2,02 An AlertType value of 40 corresponds to the Custom metric alert type. The Name taken from the alert.Alert_Type table is simply Custom metric, but this doesn’t tell us anything about the specific custom metric that this alert pertains to. That’s where the SubType value comes in. For custom metric alerts, this provides us with the Id of the specific custom alert definition that can be found in the settings.CustomAlertDefinitions table. I don’t really want to delve into custom alert definitions yet (maybe in a later post), but an extra join in the previous query shows us that this alert pertains to the CPU pressure (avg runnable task count) custom metric alert. SELECT AlertId, a.AlertType, at.Name, cad.Name AS CustomAlertName, TargetObject, [Read], SubType FROM alert.Alert a JOIN alert.Alert_Type at ON a.AlertType = at.AlertType JOIN settings.CustomAlertDefinitions cad ON a.SubType = cad.Id WHERE AlertId = 65769;  AlertIdAlertTypeNameCustomAlertNameTargetObjectReadSubType 16576940Custom metricCPU pressure (avg runnable task count)7:Cluster,1,4:Name,s7:granger,9:SqlServer,1,4:Name,s0:,8:Database,1,4:Name,s6:master,12:CustomMetric,1,8:MetricId,I2,02 The TargetObject value in this case breaks down like this: "7:Cluster,1,4:Name,s7:granger," – Cluster named "granger". "9:SqlServer,1,4:Name,s0:," – SqlServer named "" (the default instance). "8:Database,1,4:Name,s6:master," – Database named "master". "12:CustomMetric,1,8:MetricId,I2," – Custom metric with an Id of 2. Note that the hierarchy for a custom metric is slightly different compared to the earlier Backup overdue alert. It’s root → Cluster → SqlServer → Database → CustomMetric. Also notice that, unlike Cluster, SqlServer and Database, the key property for CustomMetric is called MetricId (not Name), and the value is a bigint (not a string). Finally, delving into the custom metric tables is beyond the scope of this post, but for the sake of avoiding any future confusion, I’d like to point out that whilst the SubType references a custom alert definition, the MetricID value embedded in the TargetObject value references a custom metric definition. Although in this case both the custom metric definition and custom alert definition share the same Id value of 2, this is not generally the case. Okay, that’s enough for now, not least because as I’m typing this, it’s almost 2am, I have to go to work tomorrow, and my alarm is set for 6am – eek! In my next post, I’ll either cover the remaining three tables in the alert schema, or I’ll delve into the way SQL Monitor stores its monitoring data, as I’d originally planned to cover in this post.

    Read the article

  • Mac server default file permissions

    - by Bobby Jack
    How do I change the default file permissions for files created on a Mac server? In case it's relevant, this is a Mac Mini running Mac OS 10.6.7. It's currently used mainly as a file server, and there are several users who need to share files. These files need to be writable by all, rather than the default which is writable only by the owner. I've been trying to do something with umask and a startup script, but I'm not sure there's a startup script that will apply to connections via Finder. I also need this to apply to files created on a client (also Macs) and copied onto the server.

    Read the article

  • mysql server upgrade problem from 5.0 to 5.1

    - by Avinash
    Hi I have upgraded my mysql server from 5.0 to 5.1. But i am having a problem related to tables for InnoDB storage Engine. My default engine is InnoDB, So it is enabled in my server. But tables with InneDB engine are not displaying in phpmyadmin. Tables with MyISAM are displaying properly. and also i can't fire a query on the table with InnoDB Engine. Thanks Avinash

    Read the article

  • how to multi-boot/upgrade linux from LVM-based partition

    - by kenny-bobby
    i currently have FC3 linux which installed itself on the hard disk using LVM partitioning, so it is basically all one big partition. i would like to try some other distributions and upgrade to something newer, but don't want to lose my current capabilities and data files, and i know nothing or less about LVM. Is it possible (and if so an example would be nice) to install a non-LVM-based distribution on the LVM disk and have multi-boot options? Or do i have to start over new and drop the LVM? My guess is that i should save my /home (data files and .rc files) on a backup device first, then somewhere/somehow create a new partion for installing another distribution. Any LVM experts out there that have tried anything like this--well i sure could use some pointers and advice...

    Read the article

  • Outlook 2010 Reminder Notification/OneNote Draw Bugs

    - by Bobby Varghese
    Can Outlook 2010 send me reminder alarms when the program is closed? If not, is there an add-on for this? Also, I use OneNote to take class notes, and sometimes, I will use the draw feature. When I close the program and come back to the notebook later, the drawings will shift and be scrambled, making my notes impossible to read and a huge hassle to fix. Has MS released an update other than (KB2288640), 32-Bit Edition to fix this?

    Read the article

  • CD/DVD WRITER I/O ERROR !!!

    - by bobby
    http://www.mediafire.com/imageview.php?quickkey=jqzdbd5n0nl i am getting the above error wen i am trying to burn a cd/dvd on my dvd writer. im am getting dis error for evry cd/dvd..!! i hv included a screenshot.above. i dnt knw whether it a problem wit my dvd writer...!! im unable to write any dvds/cds im using imgburn burning software.

    Read the article

  • CD/DVD WRITER I/O ERROR !!!

    - by bobby
    http://www.mediafire.com/imageview.php?quickkey=jqzdbd5n0nl i am getting the above error wen i am trying to burn a cd/dvd on my dvd writer. im am getting dis error for evry cd/dvd..!! i hv included a screenshot.above.

    Read the article

  • How do I decrypt a password-protected PDF on OSX?

    - by Brant Bobby
    I have a PDF that requires a password to view. I know what the password is. I frequently open this PDF to print it, and find entering the password each time incredibly annoying. How can I remove the password from the PDF? Since I need to print it, simply taking a screenshot isn't a good solution. I tried printing the file to a PDF, but Preview disables the "Save as PDF..." option in the print dialog.

    Read the article

  • Is Internet routing (BGP) fully automated?

    - by Adal
    If all the routing tables on the Internet would be erased simultaneously, will the routers be able to rediscover them automatically? I'm having an argument with a colleague who says that the RIPE routing tables are essential, but I remember reading that if the tables disappeared, the BGP protocol will allow routers to rediscover working routes between nodes by querying their neighbors which in turn will query their neighbors until a working route will be detected. Then that route will be used to repopulate the routing tables. After a while, all the routes will be restored (not necessarily the optimal routes). Is that correct?

    Read the article

  • Good Books About Scaling Up Databases/Servers/etc.?

    - by Mehrdad
    I've applied for an internship at a startup company that expects its user base to grow by a large factor in a small amount of time, and so part of their project is to scale everything up so that they're ready: handling more/larger requests efficiently, handling server failures, load balancing, getting more JavaScript to run faster on the client computers, etc. Part of my job will also be figuring out what to do, so it's not obvious what my exact task will be at the moment. I was told that I should start reading up a little more about this so that I would have a little bit of an idea of what to do. What are some good books for me to read on this topic? I have a little bit of experience with the usage of MySQL (and also a little experience with web development), but in no way do I claim any knowledge on the internal workings of databases or distributed systems, so I might need readings more on the introductory side.

    Read the article

  • How can I force a MySQL table to become corrupted?

    - by Rory McCann
    I have written a simple Nagios plugin that calls mysqlcheck (which checks for corrupted tables) and will give a warning if any are corrupt. However none of my tables are corrupt now. So I'm not 100% sure that my plugin is working fine. I have a dev server that's not misson critical. How can I force one (or any) of the tables there to be corrupt so that I can test my nagios alert? For the record the server is Ubuntu Dapper and the mysql is version 5.0

    Read the article

  • Match Hard Disk Partition Table?

    - by MA1
    What is the most efficient way to match the partition tables on two different hard disks? I have saved the partition tables using dd command in linux. The partition tables are from a Windows system.

    Read the article

  • Why is the usable memory on my Macbook pro shown as 2.74 Gb when there is 4GB installed with 32bit Windows 7? [closed]

    - by Bobby Alexander
    Possible Duplicate: Windows XP and RAM 3.5GB+ Installed RAM : 4 GB but 2.96GB Usable......why? I have a Macbook Pro with 4GB of installed RAM. I have installed Windows 7 on it which shows the usable memory as 2.74GB. Why is this? Don't tell me the 32 bit story; I program for a living. The maximum addressible memory on a 32 bit system is 4 GB not 3 GB. Need proof? MSDN: Memory Limits for Windows Releases

    Read the article

< Previous Page | 72 73 74 75 76 77 78 79 80 81 82 83  | Next Page >