Search Results

Search found 22961 results on 919 pages for 'memory management'.

Page 760/919 | < Previous Page | 756 757 758 759 760 761 762 763 764 765 766 767  | Next Page >

  • Want to use something like Citrix XenClient, Free Alternative?

    - by Chris
    I'm looking to go into IT, general office server management, and it looks like XenClient would be a awesome tool to use. If I get it right, you would store a central image of the OS you want to deploy (in an iso file) on the main server. Then use XenClient to pull that image down to the client, and it will then boot the OS inside of the virtual machine. Does it download the image of the OS and store it locally (like cloning the VM onto the client?) I'd love to find a free (possibly open source?) alternative to this, I keep on hearing about KVM in Linux and PXE booting a minimalistic OS to use remote KVMs.... Would that be what I'm looking for? Ideally, I'd like a system.. - That allows me to manage one central image for multiple clients (virtualized hardware) - Easily push a new VM onto the client for easy updating. - Be able to keep files in sync (but that might be a samba / active directory's job) Would those things be possible with some kind of free alternative? Some guidance would be greatly appreciated.

    Read the article

  • Windows Server 2008 R2 Server Manager not working -> mmc.exe crashes with System.IO.FileNotFoundException

    - by Aleja_Vigo
    Since some days ago I can't run the Server Manager, it fails like this: Descripción: Stopped working Firma con problemas: Nombre del evento de problema: CLR20r3 Firma del problema 01: mmc.exe Firma del problema 02: 6.1.7600.16385 Firma del problema 03: 4a5bc808 Firma del problema 04: System.Management Firma del problema 05: 2.0.0.0 Firma del problema 06: 4ca2baf0 Firma del problema 07: 32f Firma del problema 08: 12b Firma del problema 09: System.IO.FileNotFoundException Versión del sistema operativo: 6.1.7601.2.1.0.272.7 There are other strange syntoms in the SO: Hyper-V stopped working as well, fails to load any VM information The desktop icons rearrange themselves all the time, and always on boot, after I move them. I use now an app that remembers their position to restore it... Windows Update service dissapeared, along with BITS service, I managed to recover them and installed all updates availables today I'm going nuts looking for information about these errors. Solutions that didn't work: sfc /scannow Doesn't complain about anything All windows updates applied (after recovering missing Windows Update) ServerManager.log: Only one error all the time: Error (Id=0) System.Runtime.InteropServices.COMException (0x800706D9): No hay más extremos disponibles desde el asignador de extremos. (Excepción de HRESULT: 0x800706D9) en Microsoft.Windows.ServerManager.NativeMethods.INetFwPolicy2.IsRuleGroupCurrentlyEnabled(String group) en Microsoft.Windows.ServerManager.DirectResult.GetRemoteManagementEnabled() In english : "There are no more endpoints available from the endpoint mapper" Where could I see which is the infamous file that mmc.exe is looking for in that System.IO.FileNotFoundException?? Please, any light on this would be much appreciated...

    Read the article

  • Hyper-V Virtual Ethernet Adapter not working probperly - Code 31 on Host

    - by Chris S
    I have a Windows 8.1 machine with Hyper-V installed. From a "clean" Hyper-V configuration I open Virtual Switch Manager, create an External switch with "Allow management operating system to share this network adapter", click OK. Everything seems to work properly but the host loses network connectivity. Opening Device Manager, the "Hyper-V Virtual Ethernet Adapter" is shown under the Network Adapter section with a yellow triangle, and the following message: This device is not working properly because Windows cannot load the drivers required for this device. (Code 31) An object ID was not found in the file. I tried "Uninstalling" the device, seems to work, but the device doesn't actually remove. I tried removing and re-adding the Hyper-V feature completely, no difference. Tried scf /scannow, no problems. System and Application logs show no errors. The Hyper-V-VMMS Networking log shows the following: Log Name: Microsoft-Windows-Hyper-V-VMMS-Networking Source: Microsoft-Windows-Hyper-V-VMMS Date: 10/24/2013 10:53:07 AM Event ID: 26088 Description: Failed to apply static IP settings to internal Ethernet adapter {A813DE9A-BE70-4FAE-AD31-BE4D54505A4B} ('885435B8-BE65-4EE9-826D-AB56035237ED'): Unspecified error (0x80004005). If I try to remove the Virtual Switch in Hyper-V Virtual Switch Manager I get this in that same log: Log Name: Microsoft-Windows-Hyper-V-VMMS-Networking Source: Microsoft-Windows-Hyper-V-VMMS Date: 10/24/2013 11:19:47 AM Event ID: 26142 Description: Failed while removing virtual Ethernet switch. Trying to remove the Virtual Switch leads to an error: Error applying Virtual Switch Properties changes Failed while removing virtual Ethernet switch. VM Networking does work.

    Read the article

  • Unable to set password in IIS 8 for Domain User as ApplicationPool Identity

    - by Niels R.
    I'm trying to set a Domain User account as ApplicationPool Identity in IIS 8 (Windows 2012). When trying this using the IIS Management Console I always get an error: Value does not fall within the expected range. When trying to set the identity using appcmd.exe it fails on both the command setting the username and password or the command only setting the password. Setting the username is no problem. Trying to set both the username and password [FAIL]: >appcmd set config /section:applicationPools /[name='AppPoolName'].processModel.identityType:SpecificUser /[name='AppPoolName'].processModel.userName:DOMAIN\Username /[name='AppPoolName'].processModel.password:P4ssW0rd Applied configuration changes to section "system.applicationHost/applicationPools" for "MACHINE/WEBROOT/APPHOST" at configuration commit path "MACHINE/WEBROOT/APPHOST" ERROR ( hresult:80070057, message:Failed to commit configuration changes. The parameter is incorrect. ) Trying to set only the username [SUCCESS]: >appcmd set config /section:applicationPools /[name='AppPoolName'].processModel.identityType:SpecificUser /[name='AppPoolName'].processModel.userName:DOMAIN\Username Applied configuration changes to section "system.applicationHost/applicationPools" for "MACHINE/WEBROOT/APPHOST" at configuration commit path "MACHINE/WEBROOT/APPHOST" Trying to set the password after successfully setting the username [FAIL]: >appcmd set config /section:applicationPools /[name='AppPoolName'].processModel.identityType:SpecificUser /[name='AppPoolName'].processModel.password:P4ssW0rd Applied configuration changes to section "system.applicationHost/applicationPools" for "MACHINE/WEBROOT/APPHOST" at configuration commit path "MACHINE/WEBROOT/APPHOST" ERROR ( hresult:80070057, message:Failed to commit configuration changes. The parameter is incorrect. ) I added the Domain User to the IIS_IUSRS group and allowed it to "Log on as a service". Any suggestions what I might be doing wrong?

    Read the article

  • Unable to back up SQL Server databases using a maintenance plan

    - by Stephen Jennings
    I am trying to create a maintenance plan that will run automatically and back up my SQL Server 2005 databases automatically. I create a new maintenance plan and add a "Back Up Database Task", select all databases, and choose a path to back up to. When I save and try to execute this plan, I get the following error message: =================================== Execution failed. See the maintenance plan and SQL Server Agent job history logs for details. =================================== Job 'Backup.Subplan_1' failed. (SqlManagerUI) ------------------------------ Program Location: at Microsoft.SqlServer.Management.SqlManagerUI.MaintenancePlanMenu_Run.PerformActions() I've checked the maintenance plan log, the agent log, and just about every log file I can find and there are no entries at all to help me figure out why this is failing. If I right-click on a specific database and select "Back Up", the task succeeds. I tried changing the plan to back up just that one database and it still failed. I've tried running the plan with both Windows authentication and SQL Server authentication with the sa account. I also tried specifically granting the SQL Server Agent user account full privileges on the backup folder, but it still failed. While searching the web for clues, the only solution I've run across so far suggests running sp_configure 'allow_update', 0. I tried this but allow_update was already set to 0 and it did not fix the problem. The Windows server and SQL Server have all updates applied to them. Thanks for any suggestions!

    Read the article

  • Upgraded AGPM Server cannot connect to relocated archive

    - by thommck
    We were using the Advanced Group Policy Management (AGPM) v3.0 on out Windows Server 2008 DC. It kept the archive on the C: drive. When we upgraded to AGPM v4 we relocated the archive to the D: drive. Now when we try to look at a GPO's hisory in GPMC we get the following error Failed to connect to the AGPM Server. The following error occurred: The server was unable to process the request due to an internal error. For more information about the error, either turn on IncludeExceptionDetailInFaults (either from ServiceBehaviorAttribute or from the configuration behavior) on the server in order to send the exception information back to the client, or turn on tracing as per the Microsoft .NET Framework 3.0 SDK documentation and inspect the server trace logs. System.ServiceModel.FaultException (80131501) You are able to click Retry or Cancel. Retry brings up the same error and Cancel takes you back to GPMC and the History tab displays "Archive not found". I installed the client on a Windows 7 computer (which is a n unsupported set up) and it could read the server archive without any issues. I followed the TechNet article "Move the AGPM Server and the Archive" but that didn't make a difference How can I tell the server where the archive is?

    Read the article

  • procdump on w3wp.exe: Only part of a ReadProcessMemory or WriteProcessMemory request was completed

    - by JakeS
    I'm having a problem with an IIS application that occasionally spikes up in CPU usage, and am trying to use procdump to get a memory dump for examination. I'm running "procdump.exe -64 -mA 9999" where 9999 is the pid of the process. But every time I do it, I get an error: Only part of a ReadProcessMemory or WriteProcessMemory request was completed. Doing this also recycles the apppool, relieving the CPU spike, so I can't keep trying until I get it right. Does anyone know what is going wrong? EDIT WITH MORE INFO: So far I've failed to generate a debug dump no matter what tool I try. All of them seem to generate the same sort of error. This is 2008 R2 Datacenter running IIS7 with a 64-bit asp.net web site. My best guess is that something is getting blocked, causing some requests to remain open in IIS and gradually using up resources. If I monitor the worker process using the IIS Manager and view all requests, throughout the day I'll start to see some requests that "stick" and run forever. Some of these are for static files. Some are for aspx pages. I cannot see any "common" reason for them. Every once in a while the app pool starts taking up 100% CPU and the only remedy is to kill it.

    Read the article

  • HYPER-V R2 Can not mount ISO from network location (UNC Path)

    - by Entity_Razer
    So, as the name suggest I'm trying to mount a ISO from a network share using the UNC path to a HYPER-V R2 Cluster. This is a pure Demo / test case setup with: 2x HYPER-V R2 1X NAS/iSCSI CSV Cluster Management is happening through the MMC with RSAT tools. So what i've done so far is: Set up the cluster and configure Quorum, add CSV Shares and disks, set up 1 Virtual Machine on the Hyper-1 node. What i'm trying to do is, you go to settings --- DVD Drive --- use network location ---- Pick ISO file and press "apply". Error I'm getting is either "User account does not have rights to mount iso". I changed that or stopped getting that message when I went to the HYPER-V Node settings and tabbed on: "Use Default Credentials Automatically". Now I stopped getting the "user does not have right..." message but I get the following: Error applying DVD Drive Changes Failed to remove device microsoft synthetic DVD Drive:" the specified network resource or device is no longer available" I've google'd the problem but am unable to find a solution. Anyone here able to help me out ? Much abbliged !

    Read the article

  • Smart Array P400 - Accelerator Replacement Battery Failure

    - by inflammable
    TL;DR - Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator for a Smart Array P400 controller a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? We have a slightly confusing situation with a Smart Array P400 storage controller with the 512mb battery backed accelerator addon on an HP DL380 server. The storage controller is (afaik) running the latest firmware and driver: Model: Smart Array P400 Controller Status: OK Firmware Version: 7.24 Serial Number: *snip* Rebuild Priority: Medium Expand Priority: Medium Number Of Ports: 2 The storage diagnostic (both on the both boot-up screen for the controller and within the 'Management Homepage' and the 'HP Array Diagnostic Utility') recently starting showing the following status a fault for the battery for the accelerator: Accelerator Status: Temporarily Disabled Error Code: Cache Disabled Low Batteries Serial Number: *snip* Total Memory: 524288 KB Read Cache: 25% Write Cache: 75% Battery Status: Failed Read Errors: 0 Write Errors: 0 We replaced the battery with a new unit (a visual inspection of the P400 card showing nothing unusual) and saw the same fault - but expected this to disappear over the course of a few hours/days as it charged. This didn't happy, and the fault status remains the same as above. Given the battery is a genuine part from HP, I wouldn't have expected a replacement battery to fail straight away, or to be dead-on-arrival (is that naivety on my part?). Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? Is there any diagnostic that could tell me more about the failed battery, without cracking the server open again? Many thanks!

    Read the article

  • Occasional disk I/O errors in SQLite

    - by Alix Axel
    I have a very simple website running PHP and SQLite 3.7.9 (with PDO). After establishing the SQLite connection I immediately execute the following queries: PRAGMA busy_timeout=0; PRAGMA cache_size=8192; PRAGMA foreign_keys=ON; PRAGMA journal_size_limit=67110000; PRAGMA legacy_file_format=OFF; PRAGMA page_size=4096; PRAGMA recursive_triggers=ON; PRAGMA secure_delete=ON; PRAGMA synchronous=NORMAL; PRAGMA temp_store=MEMORY; PRAGMA journal_mode=WAL; PRAGMA wal_autocheckpoint=4096; This website only has one writer and a few occasional readers, so I don't expect any concurrency problems (and I'm even using WAL). Every couple of days, I've seen this error being reported by PHP: Fatal error: Uncaught exception 'PDOException' with message 'SQLSTATE[HY000]: General error: 10 disk I/O error' in ... Stack trace: #0 ...: PDO-exec('PRAGMA cache_si...') There are several things that make this error very weird to me: it's not a transient problem - no matter how many times I refresh the page, it won't go away the database file is not corrupted - the sqlite3 executable can open the database without problems If the following pragmas are commented out, PHP stops throwing the disk I/O exception: PRAGMA cache_size=8192; PRAGMA synchronous=NORMAL; PRAGMA journal_mode=WAL; Then, after successfully reconnecting to the database, I'm able to reintroduce these pragmas and the code with run smoothly for days - until eventually, the same error will occur without any apparent reason. I wasn't able to reproduce this error so far, so I'm clueless about the origin of it. I'm really curious what may be causing this problem... Any ideas? Environment: Ubuntu Server 12.04 LTS PHP 5.4.15 SQLite 3.7.9 Database size: ? 10MiB Transaction (write) size: ? 1KiB EDIT: Might these symptoms have something to do with busy_timeout?

    Read the article

  • powershell v2 remoting - How do you enable unecrypted traffic

    - by Peter Walke
    I'm writing a powershell v2 script that I'd like to run against a remote server. When I run it, I get the error : Connecting to remote server failed with the following error message : The WinRM client cannot process the request. Unencrypted traffic is currently disabled in the client configuration. Change the client configurati on and try the request again. For more information, see the about_ Remote_Troubleshooting Help topic. I looked at the online help for about _ Remote_Troubleshooting, but it didn't point me towards how to enable unecrypted traffic. Below is the script that I'm using that is causing me problems. Note: I have already run Enable-PSRemoting on the remote machine to allow it to accept incoming requests. I have tried to use a session option variable, but it doesn't seem to make any difference. $key = "HKLM:\SOFTWARE\Microsoft\PowerShell\1\ShellIds" Set-ItemProperty $key ConsolePrompting True $tvar = "password" $password = ConvertTo-SecureString -string $tvar -asPlainText –force $username="domain\username" $mySessionOption = New-PSSessionOption -NoEncryption $credential = New-Object System.Management.Automation.PSCredential($username,$password) invoke-command -filepath C:\scripts\RemoteScript.ps1 -sessionoption $mySessionOption -authentication digest -credential $credential -computername RemoteServer How do I enable unencrypted traffic?

    Read the article

  • Can't successfully run Sharepoint Foundation 2010 first time configuration

    - by Robert Koritnik
    I'm trying to run the non-GUI version of configuration wizard using power shell because I would like to set config and admin database names. GUI wizard doesn't give you all possible options for configuration. I run this command: New-SPConfigurationDatabase -DatabaseName "Sharepoint2010Config" -DatabaseServer "developer.pleiado.pri" -AdministrationContentDatabaseName "Sharepoint2010Admin" -DatabaseCredentials (Get-Credential) -Passphrase (ConvertTo-SecureString "%h4r3p0int" -AsPlainText -Force) Of course all these are in the same line. I've broken them down into separate lines to make it easier to read. When I run this command I get this error: New-SPConfigurationDatabase : Cannot connect to database master at SQL server a t developer.pleiado.pri. The database might not exist, or the current user does not have permission to connect to it. At line:1 char:28 + New-SPConfigurationDatabase <<<< -DatabaseName "Sharepoint2010Config" -Datab aseServer "developer.pleiado.pri" -AdministrationContentDatabaseName "Sharepoint 2010Admin" -DatabaseCredentials (Get-Credential) -Passphrase (ConvertTo-SecureS tring "%h4r3p0int" -AsPlainText -Force) + CategoryInfo : InvalidData: (Microsoft.Share...urationDatabase: SPCmdletNewSPConfigurationDatabase) [New-SPConfigurationDatabase], SPExcep tion + FullyQualifiedErrorId : Microsoft.SharePoint.PowerShell.SPCmdletNewSPCon figurationDatabase I created two domain accounts: SPF_DATABASE - database account SPF_ADMIN - farm account I'm running powershell console as domain administrator. I've tried to run SQL Management studio as domain admin and created a dummy database and it worked wothout a problem. I'm running: Windows 7 x64 on the machine where Sharepoint Foundation 2010 should be installed and also has preinstalled SQL Server 2008 R2 Windows Server 2008 R2 Server Core is my domain controller I've installed Sharepoint according to MS guides http://msdn.microsoft.com/en-us/library/ee554869%28office.14%29.aspx installing all additional patches that are related to my configuration. Any ideas what should I do to make it work?

    Read the article

  • Cacti rrdtool graph with no values, NaN in .rrd file

    - by beicha
    Cacti 0.8.7h, with latest RRDTool. I successfully graphed CPU/Interface traffic, but got blank graphs like when it comes to Memory/Temperature monitoring. The problem/bug is actually archived here, however this post didn't help. I can snmpget the value, e.g SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1 = Gauge32: 26. However, the problem seems to exist in storing these values to the .rrd file. Output of rrdtool info powerbseipv6testrouter_cisco_memfree_40.rrd AVERAGE cisco_memfree as below: filename = "powerbseipv6testrouter_cisco_memfree_40.rrd" rrd_version = "0003" step = 300 last_update = 1321867894 ds[cisco_memfree].type = "GAUGE" ds[cisco_memfree].minimal_heartbeat = 600 ds[cisco_memfree].min = 0.0000000000e+00 ds[cisco_memfree].max = 1.0000000000e+12 ds[cisco_memfree].last_ds = "UNKN" ds[cisco_memfree].value = 0.0000000000e+00 ds[cisco_memfree].unknown_sec = 94 rra[0].cf = "AVERAGE" rra[0].rows = 600 rra[0].pdp_per_row = 1 rra[0].xff = 5.0000000000e-01 rra[0].cdp_prep[0].value = NaN rra[0].cdp_prep[0].unknown_datapoints = 0 rra[1].cf = "AVERAGE" rra[1].rows = 700 rra[1].pdp_per_row = 6 rra[1].xff = 5.0000000000e-01 rra[1].cdp_prep[0].value = NaN rra[1].cdp_prep[0].unknown_datapoints = 0 rra[2].cf = "AVERAGE" rra[2].rows = 775 rra[2].pdp_per_row = 24 rra[2].xff = 5.0000000000e-01 rra[2].cdp_prep[0].value = NaN rra[2].cdp_prep[0].unknown_datapoints = 18 rra[3].cf = "AVERAGE" rra[3].rows = 797 rra[3].pdp_per_row = 288 rra[3].xff = 5.0000000000e-01 rra[3].cdp_prep[0].value = NaN rra[3].cdp_prep[0].unknown_datapoints = 114 rra[4].cf = "MAX" rra[4].rows = 600 rra[4].pdp_per_row = 1 rra[4].xff = 5.0000000000e-01 rra[4].cdp_prep[0].value = NaN rra[4].cdp_prep[0].unknown_datapoints = 0 rra[5].cf = "MAX" rra[5].rows = 700 rra[5].pdp_per_row = 6 rra[5].xff = 5.0000000000e-01 rra[5].cdp_prep[0].value = NaN rra[5].cdp_prep[0].unknown_datapoints = 0 rra[6].cf = "MAX" rra[6].rows = 775 rra[6].pdp_per_row = 24 rra[6].xff = 5.0000000000e-01 rra[6].cdp_prep[0].value = NaN rra[6].cdp_prep[0].unknown_datapoints = 18 rra[7].cf = "MAX" rra[7].rows = 797 rra[7].pdp_per_row = 288 rra[7].xff = 5.0000000000e-01 rra[7].cdp_prep[0].value = NaN rra[7].cdp_prep[0].unknown_datapoints = 114

    Read the article

  • uWSGI log file...permission denied to read file

    - by bkev
    I have a server running Django/Nginx/uWSGI with uWSGI in emperor mode, and the error log for it (the vassal-level error log, not the emperor-level log) has a continual permissions error every time it spawns a new worker, like so: Tue Jun 26 19:34:55 2012 - Respawned uWSGI worker 2 (new pid: 9334) Error opening file for reading: Permission denied Problem is, I don't know what file it's having trouble opening; it's not the log file, obviously, since I'm looking at it and it's writing to that without issue. Any way to find out? I'm running the apt-get version of uWSGI 1.0.3-debian through Upstart on Ubuntu 12.04. The site is working successfully, aside from what seems like a memory leak...hence my looking at the log file. My Upstart conf file description "uWSGI" start on runlevel [2345] stop on runlevel [06] respawn env UWSGI=/usr/bin/uwsgi env LOGTO=/var/log/uwsgi/emperor.log exec $UWSGI \ --master \ --emperor /etc/uwsgi/vassals \ --die-on-term \ --auto-procname \ --no-orphans \ --logto $LOGTO \ --logdate My Vassal ini file: [uwsgi] # Variables base = /srv/env/mysiteenv # Generic Config uid = uwsgi gid = uwsgi socket = 127.0.0.1:5050 master = true processes = 2 reload-on-as = 128 harakiri = 60 harakiri-verbose = true auto-procname = true plugins = http,python cache = 2000 home = %(base) pythonpath = %(base)/mysite module = wsgi logto = /srv/log/mysite/uwsgi_error.log logdate = true

    Read the article

  • Extract Key and Certificate from Kemp Loadmaster?

    - by Matt Simmons
    I'm trying very hard to get away from a set of Kemp Loadmasters that I bought years ago to provide HA access to our website. Part of that process is going to be putting the key and certificate in the new solution (HAproxy with nginx doing SSL). Unfortunately, I've come up against a problem... The Kemp has built-in certificate management, and it generates CSR's at the touch of a button. It also supported importing of signed certificates, however it does not, so far as I can tell, allow any kind of export of the key itself. There is a "backup key and certificates" ability, however here's the text from the manual: LoadMaster supports exporting of ALL certificate information. This includes private key, host and intermediate certificates. The export file is designed to be used for import into another LoadMaster and is encrypted. Export and import can be completed using the WUI at Certificates -> Backup/Restore Certs. Please make sure to note the pass phrase used to create the export, it will be required to complete the import. You can selectively resort only Virtual Service certificates including private keys, intermediate certificates or both. Well, that is great, but as for actually DEALING with the certs, I'm apparently out of luck. Of course, I'm not going to give up that easily. I ran "file" on the saved cert bundle and got this: $ file client1.certs.backup client1.certs.backup: gzip compressed data, from Unix Well, awesome, I thought. Maybe it's just a .tar.gz, so I unzipped it, and that went fine, but my attempts to untar it didn't work, and running "file" on it now just gives this: $ file client1.certs.backup client1.certs.backup: data So that's where I'm stuck. Anyone have experience with these?

    Read the article

  • Why does Mass Effect 1 run so slow on my machine if I have an XFX NVidia 9400GT video card? [closed]

    - by Papuccino1
    I so sick and tired of having my components pass the minimum requirements of a game and then I get 15 FPS on the game on everything low. Should't PC developers say 'use at least this video card for a smooth 30 FPS'? Here are my specs: Windows 7 2GB DDR2 RAM XFX Nvidia 9400gt Intel Pentium D Dual Core 2.8ghz I should be at LEAST getting 30 FPS on everything low right? Please tell me what I can do to make games run as they should, or is my video card not good for these games? Here are the recommended requirements from the official site: Recommended System Requirements for Mass Effect on the PC Operating System: Windows XP or Vista Processor: 2.6+GHZ Intel or 2.4+GHZ AMD Memory: 2 Gigabyte Ram Video Card: NVIDIA GeForce 7900 GTX or higher. ATI X1800 XL series or higher Hard Drive Space: 12 Gigabytes Sound Card: DirectX 9.0c compatible sound card and drivers – 5.1 sound card recommended My videocard is 9400GT, how is that worse than a 7900GTX? :S Edit 2: I should note, that I get poor frames when running the game in absolute BOTTOM specs. lowest resolution, no particles, etc. etc. Absolute ZERO and getting poor framerates.

    Read the article

  • i5 540M or i7 720QM for laptop running VMs and software development tools?

    - by Donald Hughes
    I'm a software developer that would primarily be running Windows 7 as the primary operating system. On a typical day, I might, at any given moment, be running Visual Studio, Expression Web, SQL Server developer (and Management Console), IIS, Photoshop, a dozen browser tabs in 2-3 different browsers, Skype video chat, streaming music, and a couple of VMs (WinXP and Ubuntu) for testing/experimentation. Obviously, RAM is a concern, which is why I plan to use 8 GB so I can devote enough to the VMs to be usable. I'm also tempted to use an ExpressCard SSD for storing the VM disks to ease disk contention. And I know that that is asking a lot from a laptop, and I should just use a desktop, but I need to be able to take my work with me between several locations. It seems that at a reasonable price point, it comes down to the i5 540M versus the i7 720QM. I'm leaning toward the i7 since it would allow me to dedicate a whole hyperthreaded core to each VM, and still have two cores left for the primary OS. I've heard that the i5 has better battery life, but I'm curious for my scenario if there would be a meaningful difference. I don't usually work without a plug, but I do occasionally ride the train or fly and it would be nice to have at least 3 hours of juice for unusual circumstances. And, finally, for this usage scenario, would a dedicated video option be preferred over the i5's integrated video? It sounds like Visual Studio 2010 (and Windows 7) can take advantage of the video card.

    Read the article

  • Setting up Group Managed Service Account on Windows Server 2012 R2

    - by Moo MinTroll
    I have a Windows 2012 R2 domain controller called cox.win.testlab. I have set up a group of hosts where I would like to use a gMSA (Group Managed Service Account). This group is called SQLManagedHosts. I created the account by following these steps in Powershell on the domain controller: PS C:\Windows\system32> Add-KdsRootKey -EffectiveTime ((get-date).addhours(-10)) Guid ---- 9b68b1e7-db76-c4e4-4978-63c2965e5596 PS C:\Windows\system32> New-ADServiceAccount mSQL -DNSHostName cox.win.testlab -PrincipalsAllowedToRetrieveManagedPassword SQLManagedHosts PS C:\Windows\system32> Get-ADServiceAccount msql DistinguishedName : CN=mSQL,CN=Managed Service Accounts,DC=win,DC=testlab Enabled : True Name : mSQL ObjectClass : msDS-GroupManagedServiceAccount ObjectGUID : cf9df74a-38e0-4d7a-856e-9af882b08800 SamAccountName : mSQL$ SID : S-1-5-21-3443997112-87545443-1733229669-1602 UserPrincipalName : On one of the hosts listed in SQLManagedHosts, I ran: PS C:\Windows\system32> Install-ADServiceAccount msql Install-ADServiceAccount : Cannot install service account. Error Message: 'An unspecified error has occurred'. At line:1 char:1 + Install-ADServiceAccount msql + ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + CategoryInfo : WriteError: (mSQL:String) [Install-ADServiceAccount], ADException + FullyQualifiedErrorId : InstallADServiceAccount:PerformOperation:InstallServiceAcccountFailure,Microsoft.ActiveDirectory.Management.Commands.InstallADServiceAccount Any ideas why it might be failing? All servers involved are Windows Server 2012 R2.

    Read the article

  • Connectivity with SQL Server Express 2008 r2 and SQL Server 2000 on same machine

    - by Jim R
    At first glance this may same a duplicate of Installing both SQL Server 2000 and SQL Server 2008 on the same machine, but it is not. I have SQL Server 2000 and SQL Server 2008 R2 installed on the same machine and working fine. My problem lies with connecting to the 2008 R2 server from a remote machine. My connectivity needs to be TCP. The legacy installation or SQL 2000 uses the default port of 1433. The named instance is by default configured to use 'Shared Memory' and is working fine. When I configured the 2008 R2 server to use 1433 (I did not think that thru) the service refused to start becasue 1433 was already in use by the legacy SQL 2000 default instance. Doh! What I want to do is have both servers available simultaneously via TCP. both servers need not be on the same port, put if I cannot run them on the same port, then how do I configure the clients? Is there not some kind of proxy available that can monitor the 1433 port and pass the request thru to the correct SQL instance by name? Is this capability built into SQL server already? Thanks, Jim

    Read the article

  • Windows 7 on a 64-bit computer

    - by GetFree
    I read on Wikipedia that Windows 7 on a 64-bit PC needs twice as much RAM as on a 32-bit PC. I understand why is that: every number stored in memory takes 8 bytes rather than just 4. That, in simple terms, means that your amount of RAM is reduced to half when you use Windows 7 on a 64-bit computer. Now, I have a Intel Core 2 Duo Laptop with Windows Vista right now (2 GB of RAM). My question is: Since Core 2 is a 64-bit architecture, if I upgrade to Windows 7 will my laptop be working as if it had just 1 GB of RAM? Or... to say it in other words: Having a 64-bit PC with Windows 7 do you need twice as much RAM as you need on a 32-bit PC to have the same performance? If I am right, then I'd say it's a terrible business to have a 64-bit computer and Windows 7 on it (I hope I am mistaken, though). Follow-up: After some answers, I'm realizing it's not the same thing to have a 32-bit OS on a 64-bit PC than a 64-bit OS on a 64-bit PC. Apparently, the problem of Windows 7 requiring twice as much RAM on 64-bit architectures is when you have both the OS and PC supporting 64 bits. I'd like new answers to address this issue. Also, is it possible to have more that 4 GB of RAM on a 64-bit PC using a 32-bit version of Windows?

    Read the article

  • fedora12, yum not releasing "lock" after performing an action

    - by James.Elsey
    Hello, This problem has been occurring quite frequently recently and I can't seem to find a way of preventing it. Whenever I perform an action with yum such as to install or remove software, it appears to execute successfully but then I'm unable to move onto the next yum command For example, I executed yum remove skype, it appeared to remove ok, but next when I try to yum search skype it appears that yum is still processing, and I have to manually kill that process via kill 1234 (or whatever the PID is) My output is as follows [root@nevada james]# yum remove skype Loaded plugins: presto, refresh-packagekit Setting up Remove Process Resolving Dependencies --> Running transaction check ---> Package skype.i586 0:2.1.0.47-fc10 set to be erased --> Finished Dependency Resolution Dependencies Resolved ================================================================================ Package Arch Version Repository Size ================================================================================ Removing: skype i586 2.1.0.47-fc10 installed 24 M Transaction Summary ================================================================================ Remove 1 Package(s) Reinstall 0 Package(s) Downgrade 0 Package(s) Is this ok [y/N]: y Downloading Packages: Running rpm_check_debug Running Transaction Test Finished Transaction Test Transaction Test Succeeded Running Transaction Erasing : skype-2.1.0.47-fc10.i586 1/1 Removed: skype.i586 0:2.1.0.47-fc10 Complete! [root@nevada james]# yum search skype Loaded plugins: presto, refresh-packagekit Existing lock /var/run/yum.pid: another copy is running as pid 3639. Another app is currently holding the yum lock; waiting for it to exit... The other application is: PackageKit Memory : 79 M RSS (372 MB VSZ) Started: Fri Dec 18 08:39:18 2009 - 00:01 ago State : Sleeping, pid: 3639 Kernel version : 2.6.31.6-166.fc12.x86_64 Any ideas how I can prevent this behaviour? Thanks

    Read the article

  • Excel techniques for perfmon csv log file analysis

    - by Aszurom
    I have perfmon running against several servers, where I'm outputting to a .csv file data like CPU %time, memory bytes free, hard disk I/O metrics like s/write and writes/s. The ones graphing the SQL servers are also collecting SQL stats. The web servers are collecting .Net relevant stuff. I am aware of PAL, and used it as a template of what data to capture based on server type actually. I just don't think the output it generates is detailed or flexible enough - but it does a pretty remarkable job of parsing logs and making graphs. I'm borderline incompetent with Excel, so I'm hoping to be directed to some knowledge of how to take a perfmon output .csv and mine it in Excel to produce some numbers that are meaningful to me as a sysadmin. I could of course just pick a range of data and assemble a graph out of that and look for spikes and trends, but I'm convinced there is some technique to this that makes it more manageable than looking at a monsterous spreadsheet of numbers and trying to make graphs of it. Plus, it's pretty time consuming and not something I can do as a "take a glance at the servers" sort of routine. I'm graphing CPU, disk use, network b/sec, etc. in Cacti as well, which is nice for seeing big trends. The problem is that it is 5 minute averages, so a server could have a problem but it's intermittent and washes out in a 5 min average. What do you do with perfmon data that I could learn from?

    Read the article

  • OpenSolaris / Nexenta problems with NetXen 4-port NIC card (ntxn driver)

    - by ewwhite
    Hello, I'm running NexentaStor Enterprise on an HP ProLiant DL180 G6 server. The onboard NIC interfaces surface as igb0 and igb1 and work well. However, I've added an HP NC375T 4-port network card using the NetXen 3031 chipset. This card should be handled by the ntxn driver in the SUNWntxn package, but that results in "ntxn0: failed to map doorbell" messages upon boot. The network interfaces don't show up. After some research, I found HP's driver package for the card. The release notes for the driver package state: This version of the Driver is supported only on Oracle Solaris 10 5/09 & 10/09. Oracle Solaris 10 5/09 & 10/09 contain an older version of NetXen P3 driver package called SUNWntxn. So, adding another version of NetXen P3 driver package using pkgadd command might result in conflicts with the NetXen driver binary & related files. Users are advised to uninstall native SUNWntxn driver package before installing the new package. The install completes, but I end up with a different set of errors in initializing the card. ifconfig ntxn0 plumb ifconfig: cannot open link "ntxn0": DLPI link does not exist dmesg output: Jan 29 07:20:17 ch-san2 ntxn: [ID 977263 kern.warning] WARNING: Memory not available Jan 29 07:20:17 ch-san2 ntxn: [ID 404858 kern.notice] NOTICE: ntxn0: Mac registration error Trying to manually create the device files: root@ch-san2:/volumes# add_drv -i "4040,100" ntxn ("ntxn") already in use as a driver or alias. Update the driver: root@ch-san2:/volumes# update_drv -f ntxn devfsadm: driver failed to attach: ntxn Warning: Driver (ntxn) successfully added to system but failed to attach Any ideas on how to get this driver working, or should I ditch the card and go with an Intel or something else?

    Read the article

  • Server 2008 R2 - Unable to install any printer drivers

    - by toffitomek
    My problem is exactly this same as described here: Server 2008 R2 - Unable to install any printer drivers Options - google groups I have few Windows 2008 R2 (no SP1) servers in remote offices, mostly in Domain Controller, and many of them have problems installing ANY printer drivers. following errors show up in Event Log when adding printer driver under Print and Document Services/Print Management/Print Services/ /Drivers OR trying any other way to install drivers: EventID 215: Installing printer driver - failed, error code 0x57, HRESULT 0x80070057. See the event user data for context information. EventID 215: Installing printer driver Canon iR C2380/2550 PCL6 failed, error code 0x0, HRESULT 0x80070057. See the event user data for context information. EventID 215: Installing printer driver Canon iR C2380/2550 PCL6 failed, error code 0x490, HRESULT 0x80070057. See the event user data for context information. in this particular server case this is problem with Canon iRC 2380i printer with Canon Generic PCL6 Driver, but it seems to apply to any driver and any printer (tried different drivers, different versions, PCL, postscript, etc) I'm using 64 bit drivers that should be working on this platform. Any help will be appreciated.

    Read the article

  • Video and LAN Cards are not recognized on Intel DG41RQ MB

    - by artyom
    Hello, My 32 bit Debian Etch with Etch-n-Half kernel 2.6.24 and Etch-n-half video driver xserver-xorg-video-intel 2.2.1-1~etchnhalf2 does not recognize my on-board LAN and Video. I can work only with VESA display. And additional PCI LAN card (that I wanted to use for Cross-X-Cabel). output of lspci 00:00.0 Host bridge: Intel Corporation 4 Series Chipset DRAM Controller (rev 03) 00:01.0 PCI bridge: Intel Corporation 4 Series Chipset PCI Express Root Port (rev 03) 00:02.0 VGA compatible controller: Intel Corporation 4 Series Chipset Integrated Graphics Controller (rev 03) 00:1b.0 Audio device: Intel Corporation 82801G (ICH7 Family) High Definition Audio Controller (rev 01) 00:1c.0 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 1 (rev 01) 00:1c.1 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 2 (rev 01) 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01) 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01) 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01) 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01) 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1) 00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01) 00:1f.1 IDE interface: Intel Corporation 82801G (ICH7 Family) IDE Controller (rev 01) 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01) 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 01) 04:01.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10 According to MB Spec: Video: Intel G41 Express Chipset Graphics and Memory Controller Hub Graphics (GMCH) LAN: Realtek 8111D Gigabit Ethernet Controller LAN Support When I run dpkg-reconfigure xserver-xorg is suggest i810 driver but X does not start, it does not start with intel driver as well; only vesa. LAN I even can't find in lspci... the last Realtek card is external one 100MB card. Where to start from?

    Read the article

< Previous Page | 756 757 758 759 760 761 762 763 764 765 766 767  | Next Page >