Search Results

Search found 31501 results on 1261 pages for 'event log'.

Page 77/1261 | < Previous Page | 73 74 75 76 77 78 79 80 81 82 83 84  | Next Page >

  • OIM 11g notification framework

    - by Rajesh G Kumar
    OIM 11g has introduced an improved and template based Notifications framework. New release has removed the limitation of sending text based emails (out-of-the-box emails) and enhanced to support html features. New release provides in-built out-of-the-box templates for events like 'Reset Password', 'Create User Self Service' , ‘User Deleted' etc. Also provides new APIs to support custom templates to send notifications out of OIM. OIM notification framework supports notification mechanism based on events, notification templates and template resolver. They are defined as follows: Ø Events are defined as XML file and imported as part of MDS database in order to make notification event available for use. Ø Notification templates are created using OIM advance administration console. The template contains the text and the substitution 'variables' which will be replaced with the data provided by the template resolver. Templates support internationalization and can be defined as HTML or in form of simple text. Ø Template resolver is a Java class that is responsible to provide attributes and data to be used at runtime and design time. It must be deployed following the OIM plug-in framework. Resolver data provided at design time is to be used by end user to design notification template with available entity variables and it also provides data at runtime to replace the designed variable with value to be displayed to recipients. Steps to define custom notifications in OIM 11g are: Steps# Steps 1. Define the Notification Event 2. Create the Custom Template Resolver class 3. Create Template with notification contents to be sent to recipients 4. Create Event triggering spots in OIM 1. Notification Event metadata The Notification Event is defined as XML file which need to be imported into MDS database. An event file must be compliant with the schema defined by the notification engine, which is NotificationEvent.xsd. The event file contains basic information about the event.XSD location in MDS database: “/metadata/iam-features-notification/NotificationEvent.xsd”Schema file can be viewed by exporting file from MDS using weblogicExportMetadata.sh script.Sample Notification event metadata definition: 1: <?xml version="1.0" encoding="UTF-8"?> 2: <Events xmlns:xsi=http://www.w3.org/2001/XMLSchema-instance xsi:noNamespaceSchemaLocation="../../../metadata/NotificationEvent.xsd"> 3: <EventType name="Sample Notification"> 4: <StaticData> 5: <Attribute DataType="X2-Entity" EntityName="User" Name="Granted User"/> 6: </StaticData> 7: <Resolver class="com.iam.oim.demo.notification.DemoNotificationResolver"> 8: <Param DataType="91-Entity" EntityName="Resource" Name="ResourceInfo"/> 9: </Resolver> 10: </EventType> 11: </Events> Line# Description 1. XML file notation tag 2. Events is root tag 3. EventType tag is to declare a unique event name which will be available for template designing 4. The StaticData element lists a set of parameters which allow user to add parameters that are not data dependent. In other words, this element defines the static data to be displayed when notification is to be configured. An example of static data is the User entity, which is not dependent on any other data and has the same set of attributes for all event instances and notification templates. Available attributes are used to be defined as substitution tokens in the template. 5. Attribute tag is child tag for StaticData to declare the entity and its data type with unique reference name. User entity is most commonly used Entity as StaticData. 6. StaticData closing tag 7. Resolver tag defines the resolver class. The Resolver class must be defined for each notification. It defines what parameters are available in the notification creation screen and how those parameters are replaced when the notification is to be sent. Resolver class resolves the data dynamically at run time and displays the attributes in the UI. 8. The Param DataType element lists a set of parameters which allow user to add parameters that are data dependent. An example of the data dependent or a dynamic entity is a resource object which user can select at run time. A notification template is to be configured for the resource object. Corresponding to the resource object field, a lookup is displayed on the UI. When a user selects the event the call goes to the Resolver class provided to fetch the fields that are displayed in the Available Data list, from which user can select the attribute to be used on the template. Param tag is child tag to declare the entity and its data type with unique reference name. 9. Resolver closing tag 10 EventType closing tag 11. Events closing tag Note: - DataType needs to be declared as “X2-Entity” for User entity and “91-Entity” for Resource or Organization entities. The dynamic entities supported for lookup are user, resource, and organization. Once notification event metadata is defined, need to be imported into MDS database. Fully qualified resolver class name need to be define for XML but do not need to load the class in OIM yet (it can be loaded later). 2. Coding the notification resolver All event owners have to provide a resolver class which would resolve the data dynamically at run time. Custom resolver class must implement the interface oracle.iam.notification.impl.NotificationEventResolver and override the implemented methods with actual implementation. It has 2 methods: S# Methods Descriptions 1. public List<NotificationAttribute> getAvailableData(String eventType, Map<String, Object> params); This API will return the list of available data variables. These variables will be available on the UI while creating/modifying the Templates and would let user select the variables so that they can be embedded as a token as part of the Messages on the template. These tokens are replaced by the value passed by the resolver class at run time. Available data is displayed in a list. The parameter "eventType" specifies the event Name for which template is to be read.The parameter "params" is the map which has the entity name and the corresponding value for which available data is to be fetched. Sample code snippet: List<NotificationAttribute> list = new ArrayList<NotificationAttribute>(); long objKey = (Long) params.get("resource"); //Form Field details based on Resource object key HashMap<String, Object> formFieldDetail = getObjectFormName(objKey); for (Iterator<?> itrd = formFieldDetail.entrySet().iterator(); itrd.hasNext(); ) { NotificationAttribute availableData = new NotificationAttribute(); Map.Entry formDetailEntrySet = (Entry<?, ?>)itrd.next(); String fieldLabel = (String)formDetailEntrySet.getValue(); availableData.setName(fieldLabel); list.add(availableData); } return list; 2. Public HashMap<String, Object> getReplacedData(String eventType, Map<String, Object> params); This API would return the resolved value of the variables present on the template at the runtime when notification is being sent. The parameter "eventType" specifies the event Name for which template is to be read.The parameter "params" is the map which has the base values such as usr_key, obj_key etc required by the resolver implementation to resolve the rest of the variables in the template. Sample code snippet: HashMap<String, Object> resolvedData = new HashMap<String, Object>();String firstName = getUserFirstname(params.get("usr_key"));resolvedData.put("fname", firstName); String lastName = getUserLastName(params.get("usr_key"));resolvedData.put("lname", lastname);resolvedData.put("count", "1 million");return resolvedData; This code must be deployed as per OIM 11g plug-in framework. The XML file defining the plug-in is as below: <?xml version="1.0" encoding="UTF-8"?> <oimplugins xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <plugins pluginpoint="oracle.iam.notification.impl.NotificationEventResolver"> <plugin pluginclass= " com.iam.oim.demo.notification.DemoNotificationResolver" version="1.0" name="Sample Notification Resolver"/> </plugins> </oimplugins> 3. Defining the template To create a notification template: Log in to the Oracle Identity Administration Click the System Management tab and then click the Notification tab From the Actions list on the left pane, select Create On the Create page, enter values for the following fields under the Template Information section: Template Name: Demo template Description Text: Demo template Under the Event Details section, perform the following: From the Available Event list, select the event for which the notification template is to be created from a list of available events. Depending on your selection, other fields are displayed in the Event Details section. Note that the template Sample Notification Event created in the previous step being used as the notification event. The contents of the Available Data drop down are based on the event XML StaticData tag, the drop down basically lists all the attributes of the entities defined in that tag. Once you select an element in the drop down, it will show up in the Selected Data text field and then you can just copy it and paste it into either the message subject or the message body fields prefixing $ symbol. Example if list has attribute like First_Name then message body will contains this as $First_Name which resolver will parse and replace it with actual value at runtime. In the Resource field, select a resource from the lookup. This is the dynamic data defined by the Param DataType element in the XML definition. Based on selected resource getAvailableData method of resolver will be called to fetch the resource object attribute detail, if method is overridden with required implementation. For current scenario, Map<String, Object> params will get populated with object key as value and key as “resource” in the map. This is the only input will be provided to resolver at design time. You need to implement the further logic to fetch the object attributes detail to populate the available Data list. List string should not have space in between, if object attributes has space for attribute name then implement logic to replace the space with ‘_’ before populating the list. Example if attribute name is “First Name” then make it “First_Name” and populate the list. Space is not supported while you try to parse and replace the token at run time with real value. Make a note that the Available Data and Selected Data are used in the substitution tokens definition only, they do not define the final data that will be sent in the notification. OIM will invoke the resolver class to get the data and make the substitutions. Under the Locale Information section, enter values in the following fields: To specify a form of encoding, select either UTF-8 or ASCII. In the Message Subject field, enter a subject for the notification. From the Type options, select the data type in which you want to send the message. You can choose between HTML and Text/Plain. In the Short Message field, enter a gist of the message in very few words. In the Long Message field, enter the message that will be sent as the notification with Available data token which need to be replaced by resolver at runtime. After you have entered the required values in all the fields, click Save. A message is displayed confirming the creation of the notification template. Click OK 4. Triggering the event A notification event can be triggered from different places in OIM. The logic behind the triggering must be coded and plugged into OIM. Examples of triggering points for notifications: Event handlers: post process notifications for specific data updates in OIM users Process tasks: to notify the users that a provisioning task was executed by OIM Scheduled tasks: to notify something related to the task The scheduled job has two parameters: Template Name: defines the notification template to be sent User Login: defines the user record that will provide the data to be sent in the notification Sample Code Snippet: public void execute(String templateName , String userId) { try { NotificationService notService = Platform.getService(NotificationService.class); NotificationEvent eventToSend=this.createNotificationEvent(templateName,userId); notService.notify(eventToSend); } catch (Exception e) { e.printStackTrace(); } } private NotificationEvent createNotificationEvent(String poTemplateName, String poUserId) { NotificationEvent event = new NotificationEvent(); String[] receiverUserIds= { poUserId }; event.setUserIds(receiverUserIds); event.setTemplateName(poTemplateName); event.setSender(null); HashMap<String, Object> templateParams = new HashMap<String, Object>(); templateParams.put("USER_LOGIN",poUserId); event.setParams(templateParams); return event; } public HashMap getAttributes() { return null; } public void setAttributes() {} }

    Read the article

  • Issuing Current Time Increments in StreamInsight (A Practical Example)

    The issuing of a Current Time Increment, Cti, in StreamInsight is very definitely one of the most important concepts to learn if you want your Streams to be responsive. A full discussion of how to issue Ctis is beyond the scope of this article but a very good explanation in addition to Books Online can be found in these three articles by a member of the StreamInsight team at Microsoft, Ciprian Gerea. Time in StreamInsight Series http://blogs.msdn.com/b/streaminsight/archive/2010/07/23/time-in-streaminsight-i.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/07/30/time-in-streaminsight-ii.aspx http://blogs.msdn.com/b/streaminsight/archive/2010/08/03/time-in-streaminsight-iii.aspx A lot of the problems I see with unresponsive or stuck streams on the MSDN Forums are to do with how Ctis are enqueued or in a lot of cases not enqueued. If you enqueue events and never enqueue a Cti then StreamInsight will be perfectly happy. You, on the other hand, will never see data on the output as you have not told StreamInsight to flush the stream. This article deals with a specific implementation problem I had recently whilst working on a StreamInsight project. I look at some possible options and discuss why they would not work before showing the way I solved the problem. The stream of data I was dealing with on this project was very bursty that is to say when events were flowing they came through very quickly and in large numbers (1000 events/sec), but when the stream calmed down it could be a few seconds between each event. When enqueuing events into the StreamInsight engne it is best practice to do so with a StartTime that is given to you by the system producing the event . StreamInsight processes events and it doesn't matter whether those events are being pushed into the engine by a source system or the events are being read from something like a flat file in a directory somewhere. You can apply the same logic and temporal algebra to both situations. Reading from a file is an excellent example of where the time of the event on the source itself is very important. We could be reading that file a long time after it was written. Being able to read the StartTime from the events allows us to define windows that will hold the correct sets of events. I was able to do this with my stream but this is where my problems started. Below is a very simple script to create a SQL Server table and populate it with sample data that will show exactly the problem I had. CREATE TABLE [dbo].[t] ( [c1] [int] PRIMARY KEY, [c2] [datetime] NULL ) INSERT t VALUES (1,'20100810'),(2,'20100810'),(3,'20100810') Column c2 defines the StartTime of the event on the source and as you can see the values in all 3 rows of data is the same. If we read Ciprian’s articles we know that we can define how Ctis get injected into the stream in 3 different places The Stream Definition The Input Factory The Input Adapter I personally have always been a fan of enqueing Ctis through the factory. Below is code typical of what I would use to do this On the class itself I do some inheriting public class SimpleInputFactory : ITypedInputAdapterFactory<SimpleInputConfig>, ITypedDeclareAdvanceTimeProperties<SimpleInputConfig> And then I implement the following function public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.FromTicks(-1)), AdvanceTimePolicy.Adjust); } The configInfo .CtiFrequency property is a value I pass through to define after how many events I want a Cti to be injected and this in turn will flush through the stream of data. I usually pass a value of 1 for this setting. The second parameter determines the CTI timestamp in terms of a delay relative to the events. -1 ticks in the past results in 1 tick in the future, i.e., ahead of the event. The problem with this method though is that if consecutive events have the same StartTime then only one of those events will be enqueued. In this example I use the following to define how I assign the StartTime of my events currEvent.StartTime = (DateTimeOffset)dt.c2; If I go ahead and run my StreamInsight process with this configuration i can see on the output adapter that two events have been removed To see this in a little more depth I can use the StreamInsight Debugger and see what happens internally. What is happening here is that the first event arrives and a Cti is injected with a time of 1 tick after the StartTime of that event (Also the EndTime of the event). The second event arrives and it has a StartTime of before the Cti and even though we specified AdvanceTimePolicy.Adjust on the factory we know that a point event can never be adjusted like this and the event is dropped. The same happens for the third event as well (The second and third events get trumped by the Cti). For a more detailed discussion of why this happens look here http://www.sqlis.com/sqlis/post/AdvanceTimePolicy-and-Point-Event-Streams-In-StreamInsight.aspx We end up with a single event being pushed into the output adapter and our result now makes sense. The next way I tried to solve this problem by changing the value of the second parameter to TimeSpan.Zero Here is how my factory code now looks public AdapterAdvanceTimeSettings DeclareAdvanceTimeProperties<TPayload>(SimpleInputConfig configInfo, EventShape eventShape) { return new AdapterAdvanceTimeSettings( new AdvanceTimeGenerationSettings(configInfo.CtiFrequency, TimeSpan.Zero), AdvanceTimePolicy.Adjust); } What I am doing here is declaring a policy that says inject a Cti together with every event and stamp it with a StartTime that is equal to the start time of the event itself (TimeSpan.Zero). This method has plus points as well as a downside. The upside is that no events will be lost by having the same StartTime as previous events. The Downside is that because the Cti is declared with the StartTime of the event itself then it does not actually flush that particular event because in the StreamInsight algebra, a Cti commits only those events that occurred strictly before them. To flush the events we need a Cti to be enqueued with a greater StartTime than the events themselves. Here is what happened when I ran this configuration As you can see all we got through was the Cti and none of the events. The debugger output shows the stamps on the Cti and the events themselves. Because the Cti issued has the same timestamp (StartTime) as the events then none of the events get flushed. I was nearly there but not quite. Because my stream was bursty it was possible that the next event would not come along for a few seconds and this was far too long for an event to be enqueued and not be flushed to the output adapter. I needed another solution. Two possible solutions crossed my mind although only one of them made sense when I explored it some more. Where multiple events have the same StartTime I could add 1 tick to the first event, two to the second, three to third etc thereby giving them unique StartTime values. Add a timer to manually inject Ctis The problem with the first implementation is that I would be giving the events a new StartTime. This would cause me the following problems If I want to define windows over the stream then some events may not be captured in the right windows and therefore any calculations on those windows I did would be wrong What would happen if we had 10,000 events with the same StartTime? I would enqueue them with StartTime + n ticks. Along comes a genuine event with a StartTime of the very first event + 1 tick. It is now too far in the past as far as my stream is concerned and it would be dropped. Not what I would want to do at all. I decided then to look at the Timer based solution I created a timer on my input adapter that elapsed every 200ms. private Timer tmr; public SimpleInputAdapter(SimpleInputConfig configInfo) { ctx = new SimpleTimeExtractDataContext(configInfo.ConnectionString); this.configInfo = configInfo; tmr = new Timer(200); tmr.Elapsed += new ElapsedEventHandler(t_Elapsed); tmr.Enabled = true; } void t_Elapsed(object sender, ElapsedEventArgs e) { ts = DateTime.Now - dtCtiIssued; if (ts.TotalMilliseconds >= 200 && TimerIssuedCti == false) { EnqueueCtiEvent(System.DateTime.Now.AddTicks(-100)); TimerIssuedCti = true; } }   In the t_Elapsed event handler I find out the difference in time between now and when the last event was processed (dtCtiIssued). I then check to see if that is greater than or equal to 200ms and if the last issuing of a Cti was done by the timer or by a genuine event (TimerIssuedCti). If I didn’t do this check then I would enqueue a Cti every time the timer elapsed which is not something I wanted. If the difference between the two times is greater than or equal to 500ms and the last event enqueued was by a real event then I issue a Cti through the timer to flush the event Queue, otherwise I do nothing. When I enqueue the Ctis into my stream in my ProduceEvents method I also set the values of dtCtiIssued and TimerIssuedCti   currEvent = CreateInsertEvent(); currEvent.StartTime = (DateTimeOffset)dt.c2; TimerIssuedCti = false; dtCtiIssued = currEvent.StartTime; If I go ahead and run this configuration I see the following in my output. As we can see the first Cti gets enqueued as before but then another is enqueued by the timer and because this has a later timestamp it flushes the enqueued events through the engine. Conclusion Hopefully this has shown how the enqueuing of Ctis can have a dramatic effect on the responsiveness of your output in StreamInsight. Understanding the temporal nature of the product is for me one of the most important things you can learn. I have attached my solution for the demos. It is all in one project and testing each variation is a simple matter of commenting and un-commenting the parts in the code we have been dealing with here.

    Read the article

  • Logging events as an Office 2007 application opens.

    - by Joshua King
    Is it possible to log what a Microsoft Office 2007 application does as it starts up. We are having an issue with Word where it hangs on the splash screen for a particular user and no one else and would like to find out what is causing it to hang. Windows event viewer only shows that the application was terminated unexpectedly because of a hang.

    Read the article

  • Nagios vs Splunk

    - by dan_vitch
    I am looking to implement log tracking at my current company. After some research it seems Nagios and Splunk are the two best options. I was wondering if there is a consensus with which is better. I understand that Splunk can be quite pricey if the non-free version is used. That being said I can imagine the answer to my question will be "If you have the money use Splunk, if not use Nagios"

    Read the article

  • tomcat6 on ubuntu fails when user set to root

    - by J G
    I'm well aware that running tomcat6 is really bad from a security point of view - and opens the box it is running on to all kinds of security risks and attack vectors. That said: When I change the entry in the /etc/init.d/tomcat6 to TOMCAT6_USER=root and then run sudo /etc/init.d/tomcat6 start I get [fail] and nothing is written to the logs under /var/log/tomcat6 and no entry for tomcat6 is created under /var/run How do I diagnose what is going wrong?

    Read the article

  • need help with logparser on iis logs

    - by user36440
    I am using logparser 2.2 and need a script that does two things: finding urls that contain a value within referer need to loop over 30 folders logparser -rpt:-1 "select count(*)INTO feeds.txt from u_ex100302*.log where to_lowercase(cs(Referer)) like '/feeds%'"

    Read the article

  • Free Windows Application Blocker/Monitor

    - by Click Ok
    I want a free application monitor that when detects certain keywords on window title by example, it closes the application (or prevents that it opens/install). Nice extra will be if the program log the application activity too and internet sites accessed by any browser. Thank you very much! PS: I'm using Windows 7 Ultimate.

    Read the article

  • SQL Server 2005, Huge LDF file.

    - by Scott Jackson
    Hi, I have a database running on SQL Server 2005. The database is 20Gb and the LDF file is 35Gb ! I'm now running low on disk space and want to shrink the log file. How can I do this and how can I stop this happening again ? Many thanks Scott

    Read the article

  • How can I force a merge of all WAL files in pg_xlog back into my base "data" directory?

    - by Zac B
    Question: Is there a way to tell Postgres (9.2) to "merge all WAL files in pg_xlog back into the non-WAL data files, and then delete all WAL files successfully merged?" I would like to be able to "force" this operation; i.e. checkpoint_segments or archiving settings should be ignored. The filesystem WAL buffer (pg_xlog) directory should be emptied, or nearly emptied. It's fine if some or all of the space consumed by the pg_xlog directory is then consumed by the data directory; our DBA has asked for WAL database backups without any backlogged WALs, but space consumption is not a concern. Having near-zero WAL activity during this operation is a fine constraint. I can ensure that the database server is either shut down or not connectible (zero user-generated transaction load) during this process. Essentially, I'd like Postgres to ignore archiving/checkpoint retention policies temporarily, and flush all WAL activity to the core database files, leaving pg_xlog in the same state as if the database were recently created--with very few WAL files. What I've Tried: I know that the pg_basebackup utility performs something like this (it generates an almost-all-WALs-merged copy of a Postgres instance's data directory), but we aren't ready to use it on all our systems yet, as we are still testing replication settings; I'm hoping for a more short-term solution. I've tried issuing CHECKPOINT commands, but they just recycle one WAL file and replace it with another (that is, if they do anything at all; if I issue them during database idle time, they do nothing). pg_switch_xlog() similarly just forces a switch to the next log segment; it doesn't flush all queued/buffered segments. I've also played with the pg_resetxlog utility. That utility sort of does what I want, but all of its usage docs seem to indicate that it destroys (rather than flushing out of the transaction log and into the main data files) some or all of the WAL data. Is that impression accurate? If not, can I use pg_resetxlog during a zero-WAL-activity period to force a flush of all queued WAL data to non-WAL data? If the answer to that is negative, how can I achieve this goal? Thanks!

    Read the article

  • Complete stack traces from Hyperic

    - by Mike Kushner
    I've setup Hyperic to run on our CI-machine, and every once in a while it reacts to some random stack trace and sends of an alert. So far so good, we've caught a lot of intermittent bugs that way. My only issue is that the alert only contains the first error line and not the entire stack trace, which requires me to access the machine and look at the logs manually. Is there any way to modify the alert message to contain more information, alternatively to include the log file in the alert mail?

    Read the article

  • How to enable Windows Mobile 6 logs?

    - by Serge - appTranslator
    Hi All, Someone told me that one can enable Windows Mobile simply by creating a bunch of registry values as explained in this TechEd article. The article is in the scopê of MS System Configuration Manager but my client tells me that the logs can be created even without System Config Manager. I tried but I couldn't get the system to create any such log file. Can anyone explain how to get this logs (or why I can't get them)? TIA,

    Read the article

  • is this a hacker or normal apache logs?

    - by Max
    Hey, just checked my Apache logs and stumbled upon this log: Client denied by server configuration. What I found weird, are the different phpMyAdmin versions. The IP is in Czech: http://whois.domaintools.com/188.120.221.206 Am I just too overcautious?

    Read the article

  • IIS EventLog Errors

    - by chris
    I keep getting this error in my event viewer on IIS 6. I'm trying to figure out if my error resets my connection (maybe recycles the worker processes?). The error is: An attempt was made to load filter 'C:\Program Files\Software Artisans\FileUp \FileUpIsapi.dll' but it requires the SF_NOTIFY_READ_RAW_DATA filter notification and this notification is not supported in Worker Process Isolation Mode. For more information, see Help and Support Center at http://go.microsoft.com/fwlink /events.asp.

    Read the article

  • Network Services disabled (not starting) on Windows XP

    - by Rickesh John
    I am currently running Windows XP Service Pack 3 on my system. But today, when I failed to connect to the internet, via a LAN cable, I realized that almost all of the vital network services had stopped functioning. Any attempts to start it through services.msc gives me the following message: Could not start the DNS Client Service on Local Computer Error 1068: The dependency service group failed to start All my software or services that are related to networking have stopped functioning, for example, Windows Firewall is turned off permanently, so is my Avast Anti-Virus' service of Real Time Shields and Web Shield. When I insert the LAN wire into my laptop, it registers itself, but this is what I get when I do a ping localhost C:>ping localhost Unable to contact IP driver, error code 2 Moveover, with ipconfig I get this : Windows IP Configuration An internal error occurred: The request is not supported. Please contact Microsoft Product Support Services for further help. Additional Information: Unable to query host name On some further poking around, I saw that none of the "NETWORK SERVICE" process in task manager, except svchost.exe were running. Also, when I first opened the task manager, I saw some 20 processes running with username column empty for most of them. With some search in Google, I found out that these services were important, DHCP DNS Net logon Network connection Network location Awareness TCP/IP Net BIOS Helper none of them, except Network Connections are working, they do not start. The event viewer of my system shows a bunch of 7000 and 7001 event errors. I have tried re installing the network driver, booting in safe mode with networking and tried to enable those services mentioned above. I had disabled System Restore some time back, so I have no restore points for my system. I tried a lot of things from Google searches but none of them worked. Also, with such a long list of issue, I am a little confused as to what should I search on the internet. :( One more thing I would like to mention, previous morning, my anti-virus Avast detected a RootKit buried deep in my system folders. It was removed, but maybe this was a problem caused by the root kit. I did run a boot-time scan but no viruses were found. Please please please advice. Is formatting and re-installation of Windows my only option?

    Read the article

  • Lots of Failure Alerts on my DC

    - by Param
    I am receiving lots of Failure Audit logs on my DC, can you guide me - how should i identify the culprit. Please see the below print-screen for more detail. The logon type is 3, that means it is a network logon. I have identify the Workstation from the log, but how should i prove who or which process is sending broadcast with logon authentication to my DC. The Anti-virus is also updated. Note:- The Workstation is in Workgroup.

    Read the article

  • What is the best tool to aggregate traffic stats from multiple nginx servers?

    - by gekkz
    The setup: 2 or more nginx machines each machine has the same virtual hosts traffic is load balanced via DNS to each machine I need to figure out what are the best tools to use to get some traffic stats, mostly interested in amount of hits and total traffic in gigabytes. Obviously, the log information will come from nginx, formatted like this: log_format main '$remote_addr $host $remote_user [$time_local] "$request" ' '$status $body_bytes_sent "$http_referer" "$http_user_agent" "$gzip_ratio"';

    Read the article

  • psloglist -w into a file

    - by user11588
    I'm trying to redirect windows event log continuously into a file. psloglist.exe has the -w feature (that listens for new events and outputs to console) so I tried combining it with redirection into a file like so: psloglist -w > out.txt It doesn't work. As new events are logged they do not show up in the file. However, if I remove > out.txt new events do shows up in the console!

    Read the article

  • DNS Query.log - Multiple query’s for ripe.net

    - by Christopher Wilson
    Currently I run a DNS server (bind9) that handles queries from clients over the internet lately I have noticed hundreds of queries from all different address's that look like this (Server IP removed) client 216.59.33.210#53: query: ripe.net IN ANY +ED (0.0.0.0) client 216.59.33.204#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) client 184.107.255.202#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) client 205.204.65.83#53: query: ripe.net IN ANY +ED (0.0.0.0) client 69.162.110.106#53: query: ripe.net IN ANY +ED (0.0.0.0) client 216.59.33.210#53: query: ripe.net IN ANY +ED (0.0.0.0) client 69.162.110.106#53: query: ripe.net IN ANY +ED (0.0.0.0) client 216.59.33.204#53: query: ripe.net IN ANY +ED (0.0.0.0) client 208.64.127.5#53: query: ripe.net IN ANY +ED (0.0.0.0) Can someone please explain why there are so many clients querying for ripe.net ?

    Read the article

  • ESXI Crash need help to understand log and support about nexentastor on virtual machine

    - by Bgnt44
    If i understand right, the following core dump means that the cpu4 has crashed the Host if i read the next line it seem that at the time the CPU 4 was assigned to the NexentaStore Vm ... SO if im right i can say that NexentaStor Vm crash my esxi Am i right ? Does that core dump can provide me some more informations ? 2012-11-14T03:48:01.046Z cpu4:6089)0x41221f25ba08:[0x41803007abff]PanicvPanicInt@vmkernel#nover+0x56 stack: 0x3000000008, 0x41221f25ba 2012-11-14T03:48:01.046Z cpu4:6089)0x41221f25bae8:[0x41803007b4a7]Panic@vmkernel#nover+0xae stack: 0x2e067c00000010, 0x0, 0x1f25bb38, 2012-11-14T03:48:01.047Z cpu4:6089)0x41221f25bc18:[0x4180300a7823]TLBDoInvalidate@vmkernel#nover+0x45a stack: 0xca, 0x0, 0x0, 0x0, 0x0 2012-11-14T03:48:01.047Z cpu4:6089)0x41221f25bc68:[0x418030489e17]UserMem_CartelFlush@<None>#<None>+0xce stack: 0xcaa0b, 0x0, 0x0, 0x4 2012-11-14T03:48:01.047Z cpu4:6089)0x41221f25bd78:[0x41803048ab91]UserMemUnmapStateCleanup@<None>#<None>+0x58 stack: 0x0, 0x41221f25bd 2012-11-14T03:48:01.047Z cpu4:6089)0x41221f25be58:[0x41803048b97d]UserMemUnmap@<None>#<None>+0x104 stack: 0x41221f267000, 0x41221f25bf 2012-11-14T03:48:01.048Z cpu4:6089)0x41221f25be98:[0x41803048bf20]UserMem_Unmap@<None>#<None>+0xe3 stack: 0x426, 0x0, 0x41221f25bef8, 2012-11-14T03:48:01.048Z cpu4:6089)0x41221f25beb8:[0x4180304a5985]UW64VMKSyscallUnpackReleasePhysMemMap@<None>#<None>+0x18 stack: 0x10 2012-11-14T03:48:01.048Z cpu4:6089)0x41221f25bef8:[0x418030476791]User_LinuxSyscallHandler@<None>#<None>+0x17c stack: 0x41803004cc70, 2012-11-14T03:48:01.048Z cpu4:6089)0x41221f25bf18:[0x4180300a82be]User_LinuxSyscallHandler@vmkernel#nover+0x19 stack: 0x3ffe63bed80, 0 2012-11-14T03:48:01.049Z cpu4:6089)0x41221f25bf28:[0x418030110064]gate_entry@vmkernel#nover+0x63 stack: 0x10b, 0x0, 0x0, 0x426, 0xcf76 2012-11-14T03:48:01.049Z cpu4:6089)VMware ESXi 5.1.0 [Releasebuild-799733 x86_64] PCPU 1 locked up. Failed to ack TLB invalidate (total of 1 locked up, PCPU(s): 1). 2012-11-14T03:48:01.050Z cpu4:6089)cr0=0x80010031 cr2=0xcaa0b750 cr3=0x197d7b000 cr4=0x42768 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:0 world:6111 name:"vmm0:Windows_2012_-_SQL" (V) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:1 world:6032 name:"vmm0:Windows_2012_-_AD" (V) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:2 world:6098 name:"vmm0:Windows_2012_-_App" (V) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:3 world:4099 name:"idle3" (IS) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:4 world:6089 name:"vmx-vcpu-0:NexentaStor" (U) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:5 world:6134 name:"vmm0:Ubuntu_-_NGINX" (V) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:6 world:4102 name:"idle6" (IS) 2012-11-14T03:48:01.050Z cpu4:6089)pcpu:7 world:4103 name:"idle7" (IS) 2012-11-14T03:48:01.050Z cpu4:6089)@BlueScreen: PCPU 1 locked up. Failed to ack TLB invalidate (total of 1 locked up, PCPU(s): 1).

    Read the article

  • How to log the actual output in apache?

    - by Oscar Rodriguez
    I am doing LAMP development for a mobile platform. However, the client browser does not allow me to view the source code of visited pages. I consider the source code to be of huge importance for debugging, so I would like to configure my web server so every time a user makes a request, in addition to sending the client a response, that response (the actual contents of the returned page) is also stored in a file with a filename I can cross-relate with access_log (maybe ip-timestamp-filename? or maybe a unique ID in an additional column in access_log?). I've searched quite a bit, but haven't even gotten close to finding what I'm looking for. Has anybody been able to do this?

    Read the article

  • Cannot log in with created user in mysql

    - by Brian G
    Using this command GRANT ALL PRIVILEGES ON *.* to brian@'%' identified by 'password'; I try to login with: mysql -u brian -ppassword The error is: ERROR 1045 (28000): Access denied for user 'brian'@'localhost' (using password: YES) I am doing this as root and I did try to flush privileges. I tried this with countless users but it does not seem to work. I can create a user with no password and login works. Command line and from phpmyadmin

    Read the article

  • How do I fix issue causing "incomplete startup packet" log message trying to implement replication in Postgresql?

    - by colour me brad
    I've got two cloud servers running Ubuntu 13.04 and PostgreSQL 9.2. I've primarily used this blog post to aid me in setting things up. However, to do the initial database dump to the slave I'm using pg_start_backup/pg_stop_backup strategy used in this other blog post. I've read through the docs and postgres wikis as well. I ran into several problems I was able to solve, but I can't get past this wretched "the database is starting up" failure. I'm not sure if seeing "cp: cannot stat '/var/lib/postgresql/9.2/archive/00000001000000000000003A': No such file or directory" after "consistent recover state reached" is normal or the first sign of a problem. The searching I've done on "the database is starting up" and "incomplete startup packet" tells me that something is sending empty TCP packets to the slave. The only thing that even knows about the slave is the master, so I'm not sure why it's sending empty packets... Has anyone worked with this and have an idea what might be going wrong? The postgres log on the slave looks like so: 2013-08-26 13:01:38 CDT LOG: entering standby mode 2013-08-26 13:01:38 CDT LOG: restored log file "000000010000000000000039" from archive 2013-08-26 13:01:38 CDT LOG: incomplete startup packet 2013-08-26 13:01:39 CDT LOG: redo starts at 0/39000020 2013-08-26 13:01:39 CDT LOG: consistent recovery state reached at 0/390000E0 cp: cannot stat '/var/lib/postgresql/9.2/archive/00000001000000000000003A': No such file or directory 2013-08-26 13:01:39 CDT LOG: streaming replication successfully connected to primary 2013-08-26 13:01:39 CDT FATAL: the database system is starting up 2013-08-26 13:01:39 CDT FATAL: the database system is starting up 2013-08-26 13:01:40 CDT FATAL: the database system is starting up 2013-08-26 13:01:40 CDT FATAL: the database system is starting up 2013-08-26 13:01:41 CDT FATAL: the database system is starting up 2013-08-26 13:01:42 CDT FATAL: the database system is starting up 2013-08-26 13:01:42 CDT FATAL: the database system is starting up 2013-08-26 13:01:43 CDT FATAL: the database system is starting up 2013-08-26 13:01:43 CDT FATAL: the database system is starting up 2013-08-26 13:01:44 CDT FATAL: the database system is starting up 2013-08-26 13:01:44 CDT FATAL: the database system is starting up 2013-08-26 13:01:44 CDT LOG: incomplete startup packet 2013-08-26 13:03:27 CDT FATAL: the database system is starting up 2013-08-26 13:03:27 CDT FATAL: the database system is starting up 2013-08-26 13:03:30 CDT FATAL: the database system is starting up 2013-08-26 13:03:30 CDT FATAL: the database system is starting up thanks! brad

    Read the article

< Previous Page | 73 74 75 76 77 78 79 80 81 82 83 84  | Next Page >