Search Results

Search found 59257 results on 2371 pages for 'windows identity'.

Page 775/2371 | < Previous Page | 771 772 773 774 775 776 777 778 779 780 781 782  | Next Page >

  • Static route works on one computer, not the other

    - by Dan
    I have been struggling with this for a couple days now, maybe I just need some people with a fresh perspective to figure out what the issue is. Basically I have a bunch of computers that are being routed through a specific gateway in order to access a web page that is hosted internally on a separate subnet. I set up static routes on all of the computers, and they all work... except one. Here's what a route print -4 looks like for a working computer (Windows 7): =========================================================================== Interface List 14...xx xx xx xx xx xx ......Broadcom 802.11n Network Adapter 11...xx xx xx xx xx xx ......Realtek PCIe GBE Family Controller 1...........................Software Loopback Interface 1 12...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter 13...00 00 00 00 00 00 00 e0 Microsoft 6to4 Adapter 17...00 00 00 00 00 00 00 e0 Teredo Tunneling Pseudo-Interface =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 10.xxx.xxx.230 10.xxx.xxx.94 20 10.zzz.zzz.0 255.255.255.0 10.xxx.xxx.147 10.xxx.xxx.94 21 10.xxx.xxx.0 255.255.255.0 On-link 10.xxx.xxx.94 276 10.xxx.xxx.94 255.255.255.255 On-link 10.xxx.xxx.94 276 10.xxx.xxx.255 255.255.255.255 On-link 10.xxx.xxx.94 276 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 10.xxx.xxx.94 276 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 10.xxx.xxx.94 276 =========================================================================== Persistent Routes: Network Address Netmask Gateway Address Metric 10.zzz.zzz.0 255.255.255.0 10.xxx.xxx.147 1 =========================================================================== And here's a route print -4 from the station that doesn't work (also Windows 7): =========================================================================== Interface List 10...xx xx xx xx xx xx ......Realtek PCIe GBE Family Controller 1...........................Software Loopback Interface 1 12...00 00 00 00 00 00 00 e0 Microsoft 6to4 Adapter 14...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #2 16...00 00 00 00 00 00 00 e0 Teredo Tunneling Pseudo-Interface =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 10.xxx.xxx.230 10.xxx.xxx.132 276 10.zzz.zzz.0 255.255.255.0 10.xxx.xxx.147 10.xxx.xxx.132 21 10.xxx.xxx.0 255.255.255.0 On-link 10.xxx.xxx.132 276 10.xxx.xxx.132 255.255.255.255 On-link 10.xxx.xxx.132 276 10.xxx.xxx.255 255.255.255.255 On-link 10.xxx.xxx.132 276 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 10.xxx.xxx.132 276 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 10.xxx.xxx.132 276 =========================================================================== Persistent Routes: Network Address Netmask Gateway Address Metric 10.zzz.zzz.0 255.255.255.0 10.xxx.xxx.147 1 =========================================================================== Both of these stations are running Windows 7. So essentially what I am trying to do here is route all traffic to the 10.zzz.zzz.0 subnet through the 10.xxx.xxx.147 gateway. Everything else should go through the 10.xxx.xxx.230 gateway. This is the intended behavior, and again it is working everywhere but that one station. I noticed that the Active Route metric costs differ between the two stations, but I am new to the routing table and I am not sure how that is impacting the behavior. I hope I have been able to explain the situation clearly. Any help would be much appreciated. I can provide any additional information if needed!

    Read the article

  • Symantec Protection Suite and System Recovery 2011 Desktop Edition

    - by rihatum
    I am re-posting this as my previous question was being treated as if I am "Shopping or seeking Product Recommendations" even though I was NOT - BTW they have deleted my comments too which were not offensive in nature. anyway - I have re-phrased some parts of my question and I hope SF Admins "Do Not Modify / Edit" this one - will be most grateful for that. I have a lot of respect for the People who visit this SITE and help others ! Just To clarify : Just to go by SF rules - I am not seeking someone to Design this solution, I am simply seeking real world examples, experiences, technical expert opinions / suggestions, any tips or tricks they may have or any problems they may have faced while doing something similar above with these products. I am also not asking for Capacity Planning for Storage, We have done some research and I am seeking Expert Assurance / Suggestions. We (our company) are planning to deploy Symantec Endpoint Protection and Symantec Desktop Recovery 2011 Desktop Edition to our 3000 - 4000 workstations (Windows7 32 and 64) with a few 100s with Windows XP 32/64 Bit. I have read the implementation guide for SEP and have read tech-notes for Desktop Recovery 2011. Our team have planned to deploy this as follows : 1 x dedicated SQL 2008R2 for Symantec Endpoint Protection (Instead of using the Embedded Database) 1 x Dedicated SQL 2008R2 for Symantec Desktop Recovery 2011 (Instead of using the Embedded Database) 1 x Dedicated W2K8 R2 Box for the SEPM (Symantec Endpoint Protection Manager - Mgmt. APP) 1 x Dedicated W2K8 R2 Box for the Symantec Desktop Recovery 2011 Management Application Agent Deployment : As per Symantec Documentation for both of the above, an agent can be pushed via the Mgmt. Application (provided no firewalls are blocking ports required etc. - we have Windows firewall disabled already). Server Hardware : Per SQL Server : 16GB RAM + SAS DISKS + Dual XEON, RAID-10 for the SQL DB or I can always mount a LUN from our existing Hitachi or EMC SAN. SEPM Server : 16GB RAM + SAS DISKS + DUAL XEON System Recovery MGMT SERVER : 16GB RAM + SAS DISKS + DUAL XEON Above is the initial plan we have for 3000 - 4000 client workstation (Windows) Now my Questions :-) a) If we had these users distributed amongst two sites with AD DC / GC in each site, How would I restrict SEPM and Desktop Mgmt. solution to only check for users in their respective site ? b) At present all users are under one building but we are going to move some dept. to a new location (with dedicated connectivity), How would we control which SEPM / MGMT Server is responsible for which site ? c) We have netbackup in our environment backing up other servers, I am planning to protect these 4 (2 x SQL, 1 x SEPM, 1 x System Recovery Mgmt. Server) via netbackup or I can use System recovery 2011 server edition on all 4 of these boxes as well. (License is not an issue as we have the complete symantec portfolio included in our license). d) Now - Saving Desktop backups - What strategies have you implemented ? Any best practice recommendation for a large user base ? I was thinking to either mount a LUN from our Hitachi SAN on the Symantec Recovery Server itself or backup to the users hard drive locally and then copy it over to a network location ? Suggestions welcome :-) If you have anything to add / correct - that will be really helpful before diving into the actual implementation phase. Will be most grateful with your suggestions, recommendations and corrections with above - Many Thanks !

    Read the article

  • How to change the language of driver interface for Canon Pixma printers?

    - by Sammy
    Is there a way to change the language of the driver interface for Canon Pixma printers? Which language is used seems to be determined by the language of the OS or the Windows localization settings. I really don't want that, I want to be able to set the language manually to my own liking, either during the driver installation or afterwards. I have found a workaround for Pixma IP2770 where you edit the setup.ini file by replacing the language names and the DLL search paths with <SELECT> under the LANGUAGES section. So instead of... 0000=<SELECT> 0001=Arabic,RES\STRING\IJInstAR.ini,RES\DLL\IJInstAR.dll 0804=Simplified Chinese,RES\STRING\IJInstCN.ini,RES\DLL\IJInstCN.dll 0404=Traditional Chinese,RES\STRING\IJInstTW.ini,RES\DLL\IJInstTW.dll 0005=Czech,RES\STRING\IJInstCZ.ini,RES\DLL\IJInstCZ.dll 0006=Danish,RES\STRING\IJInstDK.ini,RES\DLL\IJInstDK.dll 0007=German,RES\STRING\IJInstDE.ini,RES\DLL\IJInstDE.dll 0008=Greek,RES\STRING\IJInstGR.ini,RES\DLL\IJInstGR.dll 0009=English,RES\STRING\IJInstUS.ini,RES\DLL\IJInstUS.dll 000A=Spanish,RES\STRING\IJInstES.ini,RES\DLL\IJInstES.dll 000B=Finnish,RES\STRING\IJInstFI.ini,RES\DLL\IJInstFI.dll 000C=French,RES\STRING\IJInstFR.ini,RES\DLL\IJInstFR.dll 000E=Hungarian,RES\STRING\IJInstHU.ini,RES\DLL\IJInstHU.dll 0010=Italian,RES\STRING\IJInstIT.ini,RES\DLL\IJInstIT.dll 0011=Japanese,RES\STRING\IJInstJP.ini,RES\DLL\IJInstJP.dll 0012=Korean,RES\STRING\IJInstKR.ini,RES\DLL\IJInstKR.dll 0013=Dutch,RES\STRING\IJInstNL.ini,RES\DLL\IJInstNL.dll 0014=Norwegian,RES\STRING\IJInstNO.ini,RES\DLL\IJInstNO.dll 0015=Polish,RES\STRING\IJInstPL.ini,RES\DLL\IJInstPL.dll 0016=Portuguese,RES\STRING\IJInstPT.ini,RES\DLL\IJInstPT.dll 0019=Russian,RES\STRING\IJInstRU.ini,RES\DLL\IJInstRU.dll 001D=Swedish,RES\STRING\IJInstSE.ini,RES\DLL\IJInstSE.dll 001E=Thai,RES\STRING\IJInstTH.ini,RES\DLL\IJInstTH.dll 001F=Turkish,RES\STRING\IJInstTR.ini,RES\DLL\IJInstTR.dll 0021=Indonesian,RES\STRING\IJInstID.ini,RES\DLL\IJInstID.dll You get.... 0000=<SELECT> 0001=<SELECT> 0804=<SELECT> 0404=<SELECT> 0005=<SELECT> 0006=<SELECT> 0007=<SELECT> 0008=<SELECT> 0009=English,RES\STRING\IJInstUS.ini,RES\DLL\IJInstUS.dll 000A=<SELECT> 000B=<SELECT> 000C=<SELECT> 000E=<SELECT> 0010=<SELECT> 0011=<SELECT> 0012=<SELECT> 0013=<SELECT> 0014=<SELECT> 0015=<SELECT> 0016=<SELECT> 0019=<SELECT> 001D=<SELECT> 001E=<SELECT> 001F=<SELECT> 0021=<SELECT> .... in case English is the preferred language. It's a way to force the installation program to only install the English language support. IP2770 is a model for the Asian market, so if you want to check this out you need to go to the Canon India download page (for instance) to get the driver. Unfortunately this method is not possible with my IP4000. There is no driver even available for it to download for Windows Vista. But is there really no way of changing the language of the UI in any normal way, you know... without having to hack it? Besides, the driver for my printer comes with Windows Vista, so I don't even have to install any drivers. And little do I get the chance to set the language, knowing that the installation never happens. Any ideas?...

    Read the article

  • How to switch and list windows (possibly of the same application) in Unity?

    - by Bruno
    Is there a way to switch easily between specific windows belonging to the same given application? For example, open Firefox, maximise the window; then, open its History window (History menu - Show all history), maximise it too. Is there an easy way to switch between these two maximised Firefox windows, without necessarily minimising the current window (or other windows in front of the required window)? Similarly, if I open another application alongside, how can I quickly go to the Firefox window of my choice? I have tried Alt+Tab, but when coming back from another application, which of the Firefox windows I end up with seems indeterministic. Under Gnome, I would find the window I'm looking for in the bottom bar. Under OSX, I would right-click on the application's icon and choose the relevant window from the list. Under Windows 7, I would click on the application icon and choose from the smaller windows. Is there something similar that's not activated or not visible by default in Unity? Hovering my mouse until I've found somewhere worth hovering over hasn't been very successful so far. I would prefer a click-based solution, but solutions involving key short-cuts instead are welcome.

    Read the article

  • How to develop a Windows 8 app in 30 days!

    - by Scott Spradlin
    Begin your 30-day journey to create a Windows Store style app. Sign up to get started and receive: Insider tips and tricks on Windows 8 application development. Personal on-the-phone access to a Windows 8 architect*. An exclusive one-on-one Windows Store design consultation*. An opportunity to get expert help from a Microsoft Services Engineer at an App Excellence Lab. Sign up today and get started. Your new Windows 8 app could be mere days away. * Offer good only to legal residents in the 50 United States & D.C., age 18 or older to hobbyists, professionals or developers in the field of software tech who sign up for building a Windows 8 application on www.generationapp.com. Offer limited to 250 design consultations per month and 500 technical review consultations per month, on a first come first served basis. Limit of one session of each offer type per person. This offer is non-transferable and cannot be combined with any other offer. This offer ends when supplies are exhausted, and is not redeemable for cash.

    Read the article

  • Is there supposed to be a Windows Network folder in the file manager?

    - by Cindy
    I pulled my hard drive out of my computer and started with a bootable usb version of Ubuntu, which I am using that at this point. At first boot, I see that there is a Windows folder when browsing network. Since there is no operating system present, besides the usb that I boot from, should there be a Windows network folder? Original question First of all I just want to say, I wish I had tried Ubuntu a couple years ago when I first heard about it, but I was like a lot of the population and went with the "easy way" and stuck with Windows because I didn't want to take the time to learn something new. Well, about 3 months ago I realized someone had hacked into my computer, and then found they had hacked my facebook account so I decided I had better do a complete credit check. I found student loans (totalling about 30,000 so far) had recently showed up on my credit report. I think it's going to be a long, long road to recovery now but I'm hoping Ubuntu will be a start and definitely an eye opener. My relationship with Windows is over. I had 3 antivirus programs running, none were protecting me like I thought they were. Turned out a free program that I downloaded was the only one that could detect and clean the virus, but by then it was too late. Anyhow, my question is, I pulled my hard drive out of my computer and started with a bootable usb version of Ubuntu, which I am using that at this point. At first boot, I see that there is a Windows folder when browsing network. Since there is no operating system present, besides the usb that I boot from, should there be a Windows network folder? I am using a local ISP (and won't be much longer because I am very paranoid at this point) and I want to make sure all is ok before I put my new hard drive in and install Ubuntu. Any help would be appreciated. Also, I want to thank Ubuntu and the community for giving people an alternative.

    Read the article

  • Windows Azure Error: Failed to start Storage Emulator: the SQL Server instance ‘localhost\SQLExpress’ could not be found

    - by DigiMortal
    When running some of your Windows Azure applications when storage emulator is not configured you may get the following error: "Windows Azure Tools: Failed to initialize Windows Azure storage emulator. Unable to start Development Storage. Failed to start Storage Emulator: the SQL Server instance ‘localhost\SQLExpress’ could not be found.   Please configure the SQL Server instance for Storage Emulator using the ‘DSInit’ utility in the Windows Azure SDK.". Here’s how to solve this problem. You need to run DSInit utility to create database. For Windows Azure SDK 1.6 the location for DSInit utility is: C:\Program Files\Windows Azure Emulator\emulator\devstore By default DSInit expects that your database server is (local)\SQLEXPRESS but you can change it easily. If you have MSSQL instance called SQLEXPRESS then it is enough to just run DSInit. If you need some other instance then run the following command: DSInit /sqlinstance:<instance name> For default instance use “.” as instance name: DSInit /sqlinstance:. You can find more information about sqlinstance and other switches from DSInit documentation. If database was correctly created you should see dialog like this: When storage database is ready you can run your application.

    Read the article

  • how to remove obsolete device and network entries? Device manager "uninstall" option has no effect

    - by Gizmo
    I am trying to remove a few "obsolete" things which annoy me (because I like to have everything cleen, working and not interferring with each other, fresh, etc..). I tried looking for solutions without any help, so here I am to ask. My first part is about removing obsolete networks, let me explain by showing the ipconfig output: C:\windows\system32>ipconfig Windows IP Configuration Wireless LAN adapter Local Area Connection* 11: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Wireless LAN adapter Local Area Connection* 9: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Ethernet adapter LAN: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Wireless LAN adapter Wi-Fi: Connection-specific DNS Suffix . : home Link-local IPv6 Address . . . . . : fe80::c129:8d57:bbd1:3564%10 IPv4 Address. . . . . . . . . . . : 192.168.2.1 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : 192.168.2.254 Tunnel adapter isatap.home: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : home C:\windows\system32> Specificalyy the first two adapter entries annoy me because the adapters are not visible in the network connection menu (invisible folder / file visibility set to "show"): And here is the second problem altogether with the first one: No matter what I click/do, Uninstall option has no effect on the multiplexor driver. (bridging stuff, right?) I really want to remove the Wireless LAN adapter Local Area Connection entries and the adapter multiplexor stuff but it's impossible? Why is this? How can I remove them anyway?

    Read the article

  • Silverlight Cream for March 17, 2010 -- #814

    - by Dave Campbell
    In this Issue: Tim Heuer(-2-), René Schulte(-2-), Bart Czernicki, Mark Monster, Pencho Popadiyn, Alex Golesh, Phil Middlemiss, and Yochay Kiriaty. Shoutouts: Check out the new themes, and Tim Heuer's poetry skills: SNEAK PEEK: New Silverlight application themes I learned to program Windows 3.1 from reading Charles Petzold's book, and here we are again: Free ebook: Programming Windows Phone 7 Series (DRAFT Preview) Here's a blog you're going to want to watch, and first up on the blog tonight is links to the complete set of MIX10 phone sessions: The Windows Phone Developer Blog First let me get a couple of things out of my system... "Holy Crap it's March 17th already" and "Holy Crap, we're all Windows Phone Developers!" I'm sure both of those were old news to anyone that's not been in a coma since Monday, but I've been a tad busy here at #MIX10. I'm not complainin' ... I'm just sayin' From SilverlightCream.com: Getting Started with Silverlight and Windows Phone 7 Development With any new Silverlight technology we have to begin with Tim Heuer... and this is Tim's announcement of Silverlight on the Windows Phone 7 Series ('cmon, can I call it a "Silverlight Phone"? ... please?) ... hope I didn't type that out loud :) ... so... in case you fell asleep Sunday, and just woke up, Tim let the dogs out on this and we could all talk about it. In all seriousness, bookmark this page... lots of good links. A guide to what has changed in the Silverlight 4 RC Continuing the 'bookmark this page' thought... Tim Heuer also has one up on what the heck is all in the Silverlight 4 RC they released on Monday... check this out... really good stuff in there... and a great post detailing it all. The Silverlight 4 Release Candidate René Schulte has a good post up detailing the new stuff in Silverlight 4 RC, with special attention paid to the webcam/mic and AsyncCaptureImage Let it ring - WriteableBitmapEx for Windows Phone René Schulte has a Windows Phone post up as well, introducing the WriteableBitmapEx library for Windows Phone... how cool is that?? Silverlight for Windows Phone 7 is NOT the same full Silverlight 3 RTM Bart Czernicki dug into the docs to expose some of the differences between Silverlight for the Windows Phone and Silverlight 3. If you've been developing in SL3 and want to also do Phone, check out this post and his resource listings. Trying to sketch a Windows Phone 7 application Mark Monster tried to SketchFlow a Windows Phone app and hit some problems... if anyone has thoughts, contribute on his blog page. Using Reactive Extensions in Silverlight – part 2 – Web Services Pencho Popadiyn has part 2 of his tutorial on Rx, and this one is concentrating on asynchronous service calls. Silverlight 4 Quick Tip: Out-Of-Browser Improvements This post from Alex Golesh is a little weird since he was sitting next to me in a session at MIX10 when he submitted it :) ... good update on what's new in OOB in the RC Turning a round button into a rounded panel I like Phil Middlemiss' other title for this post: "A Scalable Orb Panel-Button-Thingy" ... this is a very cool resizing button that works amazingly similar to the resizable skinned dialogs I did in Win32!... very cool, Phil! Go Get It – The Windows Phone Developer Training Kit Did you know there was a Windows Phone Training Kit with Hands-on Labs? Yochay Kiriaty at the Windows Phone Developer Blog wrote about it... I pulled it down, and it looks really good! Stay in the 'Light! Twitter SilverlightNews | Twitter WynApse | WynApse.com | Tagged Posts | SilverlightCream Join me @ SilverlightCream | Phoenix Silverlight User Group Technorati Tags: Silverlight    Silverlight 3    Silverlight 4    Windows Phone MIX10

    Read the article

  • Get HDD (and NOT Volume) Serial Number on Vista Ultimate 64 bit

    - by TheAgent
    Hi all. I was once looking for getting the HDD serial number without using WMI, and I found it. The code I found and posted on StackOverFlow.com works very well on 32 bit Windows, both XP and Vista. The trouble only begins when I try to get the serail number on 64 bit OSs (Vista Ultimate 64, specifically). The code returns String.Empty, or a Space all the time. Anyone got an idea how to fix this? EDIT: I used the tools Dave Cluderay suggested, with interesting results: Here is the output from DiskId32, on Windows XP SP2 32-bit: To get all details use "diskid32 /d" Trying to read the drive IDs using physical access with admin rights Drive 0 - Primary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Trying to read the drive IDs using the SCSI back door Drive 4 - Tertiary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Trying to read the drive IDs using physical access with zero rights **** STORAGE_DEVICE_DESCRIPTOR for drive 0 **** Vendor Id = [] Product Id = [MAXTOR STM3160215AS] Product Revision = [3.AAD] Serial Number = [] **** DISK_GEOMETRY_EX for drive 0 **** Disk is fixed DiskSize = 160041885696 Trying to read the drive IDs using Smart Drive 0 - Primary Controller - - Master drive Drive Model Number________________: [MAXTOR STM3160215AS] Drive Serial Number_______________: [ 6RA26XK3] Drive Controller Revision Number__: [3.AAD] Controller Buffer Size on Drive___: 2097152 bytes Drive Type________________________: Fixed Drive Size________________________: 160041885696 bytes Hard Drive Serial Number__________: 6RA26XK3 Hard Drive Model Number___________: MAXTOR STM3160215AS And DiskId32 run on Windows Vista Ultimate 64-bit: To get all details use "diskid32 /d" Trying to read the drive IDs using physical access with admin rights Trying to read the drive IDs using the SCSI back door Trying to read the drive IDs using physical access with zero rights **** STORAGE_DEVICE_DESCRIPTOR for drive 0 **** Vendor Id = [MAXTOR S] Product Id = [TM3160215AS] Product Revision = [3.AA] Serial Number = [] **** DISK_GEOMETRY_EX for drive 0 **** Disk is fixed DiskSize = 160041885696 Trying to read the drive IDs using Smart Hard Drive Serial Number__________: Hard Drive Model Number___________: Notice how much lesser the information is on Vista, and how the Serial Number is not returned. Also the other tool, EnumDisk, refers to my hard disks on Vista as "SCSI" as opposed to "ATA" on Windows XP. Any ideas? EDIT 2: I'm posting the results from EnumDisks: On Windows XP SP2 32-bit: Properties for Device 1 Device ID: IDE\DiskMAXTOR_STM3160215AS_____________________3.AAD___ Adapter Properties ------------------ Bus Type : ATA Max. Tr. Length: 0x20000 Max. Phy. Pages: 0xffffffff Alignment Mask : 0x1 Device Properties ----------------- Device Type : Direct Access Device (0x0) Removable Media : No Product ID : MAXTOR STM3160215AS Product Revision: 3.AAD Inquiry Data from Pass Through ------------------------------ Device Type: Direct Access Device (0x0) Vendor ID : MAXTOR S Product ID : TM3160215AS Product Rev: 3.AA Vendor Str : *** End of Device List

    Read the article

  • ReadFile doesn't work asynchronously on Win7 and Win2k8

    - by f0b0s
    According to MSDN ReadFile can read data 2 different ways: synchronously and asynchronously. I need the second one. The folowing code demonstrates usage with OVERLAPPED struct: #include <windows.h> #include <stdio.h> #include <time.h> void Read() { HANDLE hFile = CreateFileA("c:\\1.avi", GENERIC_READ, 0, NULL, OPEN_EXISTING, FILE_FLAG_OVERLAPPED, NULL); if ( hFile == INVALID_HANDLE_VALUE ) { printf("Failed to open the file\n"); return; } int dataSize = 256 * 1024 * 1024; char* data = (char*)malloc(dataSize); memset(data, 0xFF, dataSize); OVERLAPPED overlapped; memset(&overlapped, 0, sizeof(overlapped)); printf("reading: %d\n", time(NULL)); BOOL result = ReadFile(hFile, data, dataSize, NULL, &overlapped); printf("sent: %d\n", time(NULL)); DWORD bytesRead; result = GetOverlappedResult(hFile, &overlapped, &bytesRead, TRUE); // wait until completion - returns immediately printf("done: %d\n", time(NULL)); CloseHandle(hFile); } int main() { Read(); } On Windows XP output is: reading: 1296651896 sent: 1296651896 done: 1296651899 It means that ReadFile didn't block and returned imediatly at the same second, whereas reading process continued for 3 seconds. It is normal async reading. But on windows 7 and windows 2008 I get following results: reading: 1296661205 sent: 1296661209 done: 1296661209. It is a behavior of sync reading. MSDN says that async ReadFile sometimes can behave as sync (when the file is compressed or encrypted for example). But the return value in this situation should be TRUE and GetLastError() == NO_ERROR. On Windows 7 I get FALSE and GetLastError() == ERROR_IO_PENDING. So WinApi tells me that it is an async call, but when I look at the test I see that it is not! I'm not the only one who found this "bug": read the comment on ReadFile MSDN page. So what's the solution? Does anybody know? It is been 14 months after Denis found this strange behavior.

    Read the article

  • 2nd Year College - Learning - Microsoft Server Products

    - by Ryan
    As the title says, I just finished my first year of college (majoring in Software Engineering). Fortunately my school likes Microsoft enough, and I can get pretty much anything I want that Microsoft sells. I also can get IBM Websphere and the like for free as well. Earlier this year, I set up an oldish computer (2.6 Pentium D, x64) to run ubuntu server headless. I'm predominately a Java developer, so Apache, Maven, Nexus, Sonar, SVN, etc made it onto the machine. It worked really well for personal and school projects, especially team projects (quick ramp up). Anyways, I started to pick up C# to complement my Java knowledge (don't judge me :P), and am interested in working with some of the associated Microsoft equivalents. The machine currently has the Ubuntu install, as well as Windows 7 Ultimate. I do all of my actual development work off my laptop, also running Windows 7 Ultimate. I was wondering what software you would recommend putting on the machine. I’m not actually serving anything off the machine itself, but in Ubuntu I had it doing integration tests with Hudson on every commit, and profiling my applications, etc, etc. The machine would be running headless, and I would remote into it. Here is what I am currently leaning towards / wondering about: Windows 7 Ultimate vs Windows Server 2008 (R2) (no one is really clear why I should go with one over the other) Windows Team Foundation Sharepoint (Never used it before, kind of meh about it) IBM Websphere or Glassfish (Some Java EE web server) SQL Server 2008 A DVCS In order to better control product conflicts / limit resource use, I’m wondering if I should install things into virtual machines (I can get VmWare or Microsoft Virtualization Products) I also plan on installing everything I had running under Linux (it’s almost entirely Java based development software, so it’ll run on both, only reason I went with ubuntu during the year was because the apache build seemed better). I’m primarily looking to become familiar with enterprise software development tools, as well as get something functional that will help my development process. (IE, I’ll still use project and assign tasks even though I might be the only one to assign tasks to, just to practice doing so). Is there any other software / configuration details I should explore? Opinions on my current list? I primarily use C#, Java, and PHP. I'm familiar with ruby, and python as well. Thanks!

    Read the article

  • LSI RAID monitor reports "Consistency Check inconsistency logging disabled"

    - by carlpett
    I have a server with a LSI MegaRAID 9261-8i controller. Recently I started getting alerts like this one: Controller ID: 1 Consistency Check inconsistency logging disabled, too many inconsistencies on VD: 0 Generated on:Sat May 12 04:06:40 2012 SYSTEM DETAILS--- IP Address: 192.168.1.29 OS Name: Windows 7 x64 OS Version: 6.01 Driver Name: megasas.sys Driver Version: 4.5.1.64 IMAGE DETAILS--- BIOS Version: 2.120.33-1197 Firmware Package Version: 12.12.0-0045 Firmware Version: 3.21.00_4.11.05.00_0x05000000 VD 0 is a RAID mirror containing the system disk. I have searched and read, but cannot find any trace of how to actually do anything about this. I tried running a scandisk but that did not find anything (as I expected, since scandisk reads the disks as exposed by the controller, right?). The MegaRAID Storage Manager does not as far as I can see have any options for checking or fixing physical disks. The program claims the VD is "healty", and both disks have Error count 0. Also a bit strange is the System details in the message... The IP address is associated with the RAS (dial in) interface, and the OS should be Windows Server 2011 SBS. Has anyone else experienced this before? What can be done?

    Read the article

  • Upgraded AGPM Server cannot connect to relocated archive

    - by thommck
    We were using the Advanced Group Policy Management (AGPM) v3.0 on out Windows Server 2008 DC. It kept the archive on the C: drive. When we upgraded to AGPM v4 we relocated the archive to the D: drive. Now when we try to look at a GPO's hisory in GPMC we get the following error Failed to connect to the AGPM Server. The following error occurred: The server was unable to process the request due to an internal error. For more information about the error, either turn on IncludeExceptionDetailInFaults (either from ServiceBehaviorAttribute or from the configuration behavior) on the server in order to send the exception information back to the client, or turn on tracing as per the Microsoft .NET Framework 3.0 SDK documentation and inspect the server trace logs. System.ServiceModel.FaultException (80131501) You are able to click Retry or Cancel. Retry brings up the same error and Cancel takes you back to GPMC and the History tab displays "Archive not found". I installed the client on a Windows 7 computer (which is a n unsupported set up) and it could read the server archive without any issues. I followed the TechNet article "Move the AGPM Server and the Archive" but that didn't make a difference How can I tell the server where the archive is?

    Read the article

  • Why does chkdsk produce "Correcting error in index $I30 for file 33267" and then freeze?

    - by wcpro
    I am running chkdsk like this: chkdsk k: /x I get this error: Correcting error in index $I30 for file 33267. What does it mean? Here's the full problem: Microsoft Windows [Version 6.1.7600] Copyright (c) 2009 Microsoft Corporation. All rights reserved. C:\Windows\system32>chkdsk e: /r The type of the file system is NTFS. Volume label is RodDrobo. CHKDSK is verifying files (stage 1 of 5)... 162048 file records processed. File verification completed. 0 large file records processed. 0 bad file records processed. 0 EA records processed. 0 reparse records processed. CHKDSK is verifying indexes (stage 2 of 5)... 10 percent complete. (167130 of 208124 index entries processed) Correcting error in index $I30 for file 33267. Correcting error in index $I30 for file 33267. <--- it always reaches this spot, then hangs forever

    Read the article

  • The Message Queuing service failed to join the computer's domain 'DOMAIN' Error 0xc00e0025

    - by SimonGoldstone
    Struggling to get MSMQ installed in Domain Integration mode on Windows 2012 (Azure). So far, I've provisioned a brand new Windows Server 2012 (R2) machine on the Azure platform and installed the Active Directory role and promoted the machine to a domain controller. Once the AD was in place, I then added the MSMQ feature, along with the Directory Integration add on. However, it will not install in AD integration mode. It will only work in Workgroup mode. I can verify this by running the following powershell command: New-MSMQQueue -name Queue1 -queuetype Public When I run this command, I get the following error: New-MsmqQueue : A workgroup installation computer does not support the operation. The event viewer reveals to errors in the Application log: 1. The Message Queuing service failed to join the computer's domain 'DOMAIN'. Error 0xc00e0025: 2. Message Queuing was unable to create the msmq (MSMQ Configuration) object in Active Directory Domain Services. Error c00e0025h: I'm struggling here. Any advice?

    Read the article

  • SQL Server 2008 Cluster Installation - First network name always fails

    - by boflynn
    I'm testing failover clustering in Windows Server 2008 to host a SQL Server 2008 installation using this installation guide. My base cluster is installed and working properly, as well as clustering the DTC service. However, when it comes time to install SQL Server, my first attempt at installation always fails with the same message and seems to "taint" the network name. For example, with my previous cluster attempt, I was installing SQL Server as VSQL. After approximately 15 attempts of installation and trying to resolve the errors, e.g. changing domain accounts for SQL, setting SPNs, etc., I typoed the network name as VQSL and the installation worked. Similarly on my current cluster, I tried installing with the SQL service named PROD-C1-DB and got the same errors as last time until I tried changing the name to anything else, e.g. PROD-C1-DB1, SQL, TEST, etc., at which point the install works. It will even install to VSQL now. While testing, my install routine was: Run setup.exe from patched media, selecting appropriate options After the install fails, I'd chose "Remove node from a SQL Server failover cluster" and remove the single, failed, node Attempt to diagnose problem, inspect event logs, etc. Delete the computer account that was created for the SQL Service from Active Directory Delete the MSSQL10.MSSQLSERVER folder from the shared data drive The error message I receive from the SQL Server installer is: The following error has occurred: The cluster resource 'SQL Server' could not be brought online. Error: The group or resource is not in the correct state to perform the requested operation. (Exception from HRESULT: 0x8007139F) Along with hundreds of the following errors in the Application event log: [sqsrvres] checkODBCConnectError: sqlstate = 28000; native error = 4818; message = [Microsoft][SQL Server Native Client 10.0][SQL Server]Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. System configuration notes: Windows Server 2008 Enterprise Edition x64 SQL Server 2008 Enterprise Edition x64 using slipstreamed SP1+CU1 media Dell PowerEdge servers Fibre attached storage

    Read the article

  • Can't successfully run Sharepoint Foundation 2010 first time configuration

    - by Robert Koritnik
    I'm trying to run the non-GUI version of configuration wizard using power shell because I would like to set config and admin database names. GUI wizard doesn't give you all possible options for configuration. I run this command: New-SPConfigurationDatabase -DatabaseName "Sharepoint2010Config" -DatabaseServer "developer.pleiado.pri" -AdministrationContentDatabaseName "Sharepoint2010Admin" -DatabaseCredentials (Get-Credential) -Passphrase (ConvertTo-SecureString "%h4r3p0int" -AsPlainText -Force) Of course all these are in the same line. I've broken them down into separate lines to make it easier to read. When I run this command I get this error: New-SPConfigurationDatabase : Cannot connect to database master at SQL server a t developer.pleiado.pri. The database might not exist, or the current user does not have permission to connect to it. At line:1 char:28 + New-SPConfigurationDatabase <<<< -DatabaseName "Sharepoint2010Config" -Datab aseServer "developer.pleiado.pri" -AdministrationContentDatabaseName "Sharepoint 2010Admin" -DatabaseCredentials (Get-Credential) -Passphrase (ConvertTo-SecureS tring "%h4r3p0int" -AsPlainText -Force) + CategoryInfo : InvalidData: (Microsoft.Share...urationDatabase: SPCmdletNewSPConfigurationDatabase) [New-SPConfigurationDatabase], SPExcep tion + FullyQualifiedErrorId : Microsoft.SharePoint.PowerShell.SPCmdletNewSPCon figurationDatabase I created two domain accounts: SPF_DATABASE - database account SPF_ADMIN - farm account I'm running powershell console as domain administrator. I've tried to run SQL Management studio as domain admin and created a dummy database and it worked wothout a problem. I'm running: Windows 7 x64 on the machine where Sharepoint Foundation 2010 should be installed and also has preinstalled SQL Server 2008 R2 Windows Server 2008 R2 Server Core is my domain controller I've installed Sharepoint according to MS guides http://msdn.microsoft.com/en-us/library/ee554869%28office.14%29.aspx installing all additional patches that are related to my configuration. Any ideas what should I do to make it work?

    Read the article

  • Task Scheduler not running .bat or .vbs successfully

    - by Django Reinhardt
    Hi there, got this weird problem, which will hopefully have an obvious solution for some enlightened soul: We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs script stopped successfully executing... but oddly it worked fine when ran manually! The error given in these circumstances was always "Timeout". We thought we try a little creative thinking, and run the .vbs another way: Via a .bat file. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file is nothing more than... CScript "C:\location\script.vbs" > Log.txt But the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The log.txt file says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • IIS 7 returns 304 instead of 200

    - by Ola Herrdahl
    I have a strange issue with IIS 7. Sometimes it seems to return a 304 instead of a 200. Here is a sample request captured with Fiddler: (Note that the file requested is not located in my browsers cache yet.) GET https://[mysite]/Content/js/jquery.form.js HTTP/1.1 Accept: */* Referer: https://[mysite]/Welcome/News Accept-Language: sv-SE User-Agent: Mozilla/4.0 (compatible; MSIE 8.0; Windows NT 6.1; WOW64; Trident/4.0; SLCC2; .NET CLR 2.0.50727; .NET CLR 3.5.30729; .NET CLR 3.0.30729; Media Center PC 6.0; InfoPath.2; OfficeLiveConnector.1.4; OfficeLivePatch.1.3; .NET4.0C; .NET4.0E) Accept-Encoding: gzip, deflate Host: [mysite] Connection: Keep-Alive Cache-Control: no-cache Cookie: ... Note that there is no If-Modified-Since or If-None-Match in the request. But still the response is: HTTP/1.1 304 Not Modified Cache-Control: public Expires: Tue, 02 Mar 2010 06:26:08 GMT Last-Modified: Mon, 22 Feb 2010 21:58:44 GMT ETag: "1CAB40A337D4200" Server: Microsoft-IIS/7.5 X-Powered-By: ASP.NET Date: Mon, 01 Mar 2010 17:06:34 GMT Does anyone have a clue of what could be wrong here? I'm running IIS 7 on Windows Web Server 2008 R2.

    Read the article

  • Goldtouch USB Keyboard reverses keystrokes in fast typing -- expected?

    - by Justin Grant
    I am running into an odd keyboard problem: some key combinations end up reversed (e.g. "pl" ends up being emitted as "lp") when I'm typing quickly. The problematic ones are the key combos I hit with two adjacent fingers on my right hand-- in other words, the combos I can hit the fastest. No idea how fast is "fastest", but I guess around 50-150 msecs gap between them. I'm trying to track down whether this represents a failed keyboard, an inherent limitation of my Goldtouch USB keyboards, or a software problem on my Windows 7 Lenovo T500. I use a PS/2 version of the same Goldtouch keyboard at home with no problems. I've tried another USB keyboard with my laptop and can't repro the problem. I've also used this keyboard on other laptops without a problem. According to this SU thread, USB keyboards have higher latency than PS/2 keyboards-- up to 30 msecs. I find it hard to imagine that I can type key combos faster than 50 msecs, probably more like 100-150. Anyone encountered this problem with this or another keyboard? If so, how did you fix it? Any idea if there's a "keyboard log" or some way to diagnose the problem inside Windows?

    Read the article

  • Task Scheduler not able to execute .vbs scripts successfully

    - by Django Reinhardt
    Apologies if this has a really obvious answer! We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs scripts stopped successfully executing (always timing out)... but could still be executed manually with no problems(!). Not knowing any good reason why the Task Scheduler should start having problems, we thought we'd try a little "creative thinking", and run the .vbs another way: Via a .bat file executed by the Task Scheduler. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file run by Task Scheduler is nothing more than... CScript "C:\location\script.vbs" > Log.txt But after an attempt to run it, the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The Log.txt (as output from the .bat file above) says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • "No more threads can be created in the system" in Network and Sharing Center

    - by Zell Faze
    A while back I noticed on one of our laboratory computers (Windows 7, very little extra software installed) that the network connection icon in the system tray would claim that it had no network connection, even though it did. This issue would go away after the computer was rebooted, but would surface again the next time I looked at the computer (a few days later). Upon opening the Network and Sharing Center I am shown an actual error message, but not one that seems to give me a lot of information about what the problem is. In the place of the usual information about network adapters and whether you are connected to the Internet it simply says: "No more threads can be created in the system." The Event Viewer shows hundreds of events from different services also with the same message. "Volume Shadow Copy Service error: Unexpected error calling routine CoCreateInstance. hr = 0x800700a4, No more threads can be created in the system."; "The WinHTTP Web Proxy Auto-Discovery Service service failed to start due to the following error: A thread could not be created for the service."; "The IP Helper service terminated with the following error: No more threads can be created in the system." As far as I can tell, this message seems to mean that there is some sort of resource leak in Windows where something is creating a large number of threads and those threads are not being killed off? I've tried restarting WMI and several services related to networking, without avail. Can anyone provide more information on what "No more threads can be created in the system" might mean and what I might be able to do to fix the issue? Currently the only solution appears to be restarting.

    Read the article

  • The boot selection failed because a required device is inaccessible 0xc000000e

    - by bbodenmiller
    A family member of mine recently went on vacation and turned off their computer, something they normally do not do, upon returning home it would not turn on and now returns the error message below. Generally friends and family come to me for help with computers and I have no problem, however this time I am a bit stumped. Any suggestions would be greatly appreciated. As you can see the error message is: Status: 0xc000000e Info: The best selection failed because a required device is inaccessible. Before going to this error message it briefly flashes the Windows loading screen. I have been able to confirm through the Windows RE Command Line and the dir command that the C: drive is accessible and likely is just suffering a bootup issue. I have tried: Launching the repair process discussed in the error message three times however each time it requires a restart and then returns to the same error message. Changing the boot order to be hard drive first Getting into safe mode; F8 just results in the same error message before I can get to the menu to select safe mode I have checked to make sure the BCD (bcdedit, Boot Configuration Data) is still intact as per https://www.symantec.com/business/support/index?page=content&id=TECH160475 I plan to try (but would like additional comments on): sfc /scannow; requires a restart and thus will likely result in the error message again A memory scan Bootrec as per http://support.microsoft.com/kb/927392#method1 Swapping IDE cables/ports Resetting the BIOS I noticed others with similar issues around the web are dual-booting however this machine is not setup in a dual-boot environment. Additionally at one point this error message supposedly showed up before I started working on the computer: The instruction at 0xfbe2584d referenced memory at 0x00000008. The memory could not be read. As previously stated any additional suggestions or words of advice would be greatly apprecaited.

    Read the article

  • certutil -ping fails with 30 seconds timeout - what to do?

    - by mark
    The certificate store on my Win7 box is constantly hanging. Observe: C:\1.cmd C:\certutil -? | findstr /i ping -ping -- Ping Active Directory Certificate Services Request interface -pingadmin -- Ping Active Directory Certificate Services Admin interface C:\set PROMPT=$P($t)$G C:\(13:04:28.57)certutil -ping CertUtil: -ping command FAILED: 0x80070002 (WIN32: 2) CertUtil: The system cannot find the file specified. C:\(13:04:58.68)certutil -pingadmin CertUtil: -pingadmin command FAILED: 0x80070002 (WIN32: 2) CertUtil: The system cannot find the file specified. C:\(13:05:28.79)set PROMPT=$P$G C:\ Explanations: The first command shows you that there are –ping and –pingadmin parameters to certutil Trying any ping parameter fails with 30 seconds timeout (the current time is seen in the prompt) This is a serious problem. It screws all the secure communication in my app. If anyone knows how this can be fixed - please share. Thanks. P.S. 1.cmd is simply a batch of these commands: certutil -? | findstr /i ping set PROMPT=$P($t)$G certutil -ping certutil -pingadmin set PROMPT=$P$G EDIT1 I have succeeded to pin down the single windows API that causes the problem - DsGetDcName According to the windbg, the certutil -ping invokes it like so: PDOMAIN_CONTROLLER_INFO pdci; DWORD ret = ::DsGetDcName(NULL, NULL, NULL, NULL, DS_DIRECTORY_SERVICE_PREFERRED, &pdci); On my workstation it times out for 30 seconds and then returns error code 1355, which is ERROR_NO_SUCH_DOMAIN No domain controller is available for the specified domain or the domain does not exist. On another machine, which is accidentally a windows server 2003, it returns almost immediately with the correct domain controller name inside the returned DOMAIN_CONTROLLER_INFO structure. Now the question is what is missing on my workstation for that API to find the correct domain controller?

    Read the article

< Previous Page | 771 772 773 774 775 776 777 778 779 780 781 782  | Next Page >