Search Results

Search found 102001 results on 4081 pages for 'windows error reporting'.

Page 79/4081 | < Previous Page | 75 76 77 78 79 80 81 82 83 84 85 86  | Next Page >

  • Windows 8 preinstall downgrade to Win 7: UEFI problems :/

    - by Tim Flemming
    I have a friend who has a Hp Laptop with UEFI booting. He locked himself out of windows 8 (forgot his password)... so he called me. Well after trying to use the latest version of chntpw in UBCD5.2.6, i came to the conclusion i needed to wipe the drive and install windows 7. A little googling suggested using certain versions of chntpw, but i decided to not waste the time burning endless CDs. Anyway, He agreed to installing Win7 "I hate the big tile thingys". So i attacked with Gparted. Wiped the whole drive. Set flags to boot. Set part table as MBR. However upon trying to install win7, it still claimed i had a GPT style disk. unable to install. the only thing i can think of I'm doing wrong is not changing the bios/UEFI to legacy... My question is, If I enable legacy, somehow get the drive to actually be MBR, and use my X86 DVD, should I be good? Is there some common glitches ppl miss when dealing with GPT/EFI/UEFI? I need answers cuz he now has a blank laptop which I am responsible for. Another question. windows 8 came installed on a GPT disk. SO WHY WHEN I BOOT THE INSTALL DVD DOES IT SAY IT CANT INSTALL TO A GPT STYLE DISK??? WTF??? talk about the bleeding edge man.

    Read the article

  • One Windows Domain workstation can ping gateway but gets no internet access

    - by dindeman
    One of the (Windows XP SP3) workstations of our Windows Domain could not access internet anymore, this problem suddenly happened overnight. The domain controllers (there are three of them) are all running Windows Server 2008. First I compared the output of ipconfig /all on the faulty workstation with the output of a working workstation and it was just fine as it had always been. In particular the default gateway was correct and always remained pingable from the faulty workstation. I guessed that something was wrong with the DHCP service and I restarted the DHCP server service on all of our three DCs as well as the DHCP client service on the faulty workstation. This didn't solve the issue. I then thought of renewing the DHCP lease with ipconfig /release and ipconfig /renew and here is my first question: why did this never work? The same IP address (192.168.0.45) kept being assigned despite all my attempts to renew it (note that all our workstation are getting their TCP/IP automatically.) Even by leaving the domain and changing the computer name the same address was yet again obtained... Anyway I then proceeded to switch the TCP/IP configuration for that machine manually to another free valid IP address (192.168.0.41)... and then the internet access came back! I then cleared any traces of the previous IP in the DHCP leases list and in the DNS tables of our DCs and, after setting back the TCP/IP configuration to 'automatic', finally, the new lease would be granted (192.168.0.41) alongside with the internet access. My second question: what went suddenly wrong with the original IP address?

    Read the article

  • Repairing Windows 7 boot after Ubuntu 10.10 install

    - by Ted
    I've read various threads on this after googling, including one on this site. I had Windows 7 installed on an SSD. I wanted to try Ubuntu so I created a partition for it on the SSD and booted with the live CD to install Ubuntu. Went through the install and somehow Ubuntu carved out another partition on the SSD rather than using the one I had already created. Windows 7 would then not boot but Ubuntu would. I booted with my 7 cd and ran the automatic startup repair, it didn't find any problems. I then ran the bootsect command on the drive with 7. It said it repaired the bootmgr but Windows still would not boot and now Ubuntu won't either. I read somewhere else that it may be due to the partition that 7 was on being changed during the install. I don't care about the Ubuntu installation but I don't want to lose the 7 install, can I delete the ubuntu partition through booting with the 7 cd? Will that do any good? Thank you all! I'm stumped even though I've done startup repairs before, just not after Ubuntu install.

    Read the article

  • Grayed-Out Sleep and Hibernate Options on Windows 7 After Updating Graphics Driver

    - by Maxim Z.
    I have a Gateway M275 Tablet PC, on which I've installed Windows 7 Ultimate. The laptop is quite old, so there aren't any Win7 drivers for it, not to mention any Vista drivers. Win7 has been working for some time, but I noticed that my video output wasn't working. I went into Device Manager and found that I didn't have a driver for my video card: it just recognized it as the standard one. I searched online and found an XP driver for it, released by Gateway. Device Manager accepted this driver and prompted me to reboot. After that, I noticed that my Sleep and Hibernate options in the Shut Down menu have been grayed-out. I looked online and found that many people are attributing this to display drivers, as such an old driver would surely not be compatible with the standby procedures Windows 7 uses. To make it clear: I was able to Sleep and Hibernate before updating the drivers; now, I can't. Running powercfg /a gives me, "An internal system component has disabled this standby state," for each available standby mode. Is there some way that the driver can be modified to support hibernation? The new driver fixed my video output problem, but I guess hibernation is more important for me. If not, what steps should I take to remove the driver and just leave the standard Windows one, which previously supported hibernation and sleep on this computer? Thanks in advance.

    Read the article

  • Windows 7 using llt for ipv6

    - by Seoman
    The question asked below is based on the specific implementations of the Os not the RFC. Looking on a way to be able to assign a fixed ip address to a host, before it boots I found that Centos 6 works fine with no modifications and Windows 7 does not work at all. As defined in enter link description here exists 3 valid ways of generate a DUID: 1 Link-layer address plus time 2 Vendor-assigned unique ID based on Enterprise Number 3 Link-layer address Looking at the centos, that works fine, I can see the following autogenerated DUID: option dhcp6.client-id 0:1:0:1:19:60:25:f1:52:54:0:6b:b9:9e; and the MAC address for this host is: ifconfig eth1 | grep HWaddr eth1 Link encap:Ethernet HWaddr 52:54:00:6B:B9:9E As you can see, the DUID containts the MAC address. I can assign a fixed ip address to this host by including an entry on my dhcp server similar to: host vm { hardware ethernet 52:54:00:6B:B9:9E; fixed-address6 2001:db8:0:1::200; if packet(0,1) = 1 { log(debug,"VM Request match!"); } } And the Centos 6 gets his ip. On the windows side, I faced a common problem explained on this other link enter link description here As summary, Win7 uses the option 2 of the DUID generation or a variation of this one. On the link explains how to move it to a llt (link layer + time) but is not working fine. If I modify the DUID to one that looks like the one generated on Centos (but with the right MAC) it works as expected. Question 1 How Can I change the DUID generation for Windows 7 to be based on MAC as Centos 6 does? Thanks

    Read the article

  • Searching SharePoint site with Windows Explorer

    - by alexsome
    Every week, I manually backup recent versions of the files on my group's SharePoint site. I open the library in Windows Explorer, search for all files modified in the past week, then copy and paste them to a network location. We need this process because our SharePoint site has a quota that we would easily meet if we had unlimited versions, so we keep a history of older versions on the network. Recently I got an upgrade to my work computer and I am unable to search the site using Windows Explorer. When I run the search for files modified in the last week no results are returned. If I run a search with no criteria on the file library, all the files are found but the "modified on" field is blank. So the search results only have the file and type fields. The new computer has Windows XP, just like the old one did. I hope this makes sense. Does anyone have any clue what the problem could be? I'd be happy to provide more info if necessary. It's bugging me to no end and I'm not even sure where to begin looking - it's either a trivial issue or a very obscure one. Thanks a lot.

    Read the article

  • No "New Folder" button in windows 7

    - by user1125620
    My sibling's laptop is running windows 7 x64. The torrents folder in Documents doesn't show the New Folder button. ctrl+shift+n doesn't work either. I tried EVERYTHING here: Can't create new folder from anywhere in Windows 7 ..but nothing worked. As with the OP there, running the .reg file brings an error that says something about not being able to change the registry value while something is using it. I removed one entry at a time in the .reg file until I narrowed down the ones that were causing the problem, which were in HKEY_CLASSES_ROOT/CLSID. The only different reg value, however, was in HKEY_CLASSES_ROOT\CLSID{11dbb47c-a525-400b-9e80-a54615a090c0}\InProcServer32, for which the default value was %SystemRoot%\system32\explorerframe.dll and the value trying to be set ExplorerFrame.dll. I'm on windows 7 32bit and that's the same value I have for the entry, so I doubt that's it. The only thing I think is slightly off is that there is a user group with a strange name that only has execute and read access, and I can't grant it full control. Every time I try, it acts as if it works, but doesn't change it. I tried booting into safe mode and changing it, but it did the same thing. It is the folder where utorrent puts any new downloads, so it's possible utorrent did something, though that's never happened to me before. edit: I had renamed the folder to something else to avoid the problem, and then went onto my own computer to try to figure out what was wrong (I personally don't like using the touchpad on laptops). While searching, my sibling starting watching a movie. I minimized the movie and saw that the same thing had happened to the folder I renamed. Also changed was the file layout. It showed the different days and the files modified on those days. So, I was able to fix it by doing: Clicking Organize Layout Menu Bar On the menu bar clicking View Arrange By Folder

    Read the article

  • Error after installing Django (supposed PATH or PYTHONPATH "error")

    - by illuminated
    Hi all, I guess this is a PATH/PYTHONPATH error, but my attempts failed so far to make django working. System is Ubuntu 10.04, 64bit: mx:~/webapps$ cat /etc/lsb-release DISTRIB_ID=Ubuntu DISTRIB_RELEASE=10.04 DISTRIB_CODENAME=lucid DISTRIB_DESCRIPTION="Ubuntu 10.04 LTS" Python version: 2.6.5: @mx:~/webapps$ python -V Python 2.6.5 When I run django-admin.py, the following happens: mx:~/webapps$ django-admin.py Traceback (most recent call last): File "/usr/local/bin/django-admin.py", line 2, in <module> from django.core import management ImportError: No module named django.core Similar when I import django in python shell: mx:~/webapps$ python Python 2.6.5 (r265:79063, Apr 16 2010, 13:09:56) [GCC 4.4.3] on linux2 Type "help", "copyright", "credits" or "license" for more information. >>> import django Traceback (most recent call last): File "<stdin>", line 1, in <module> ImportError: No module named django >>> quit() More details: mx:~/webapps$ python -c "from distutils.sysconfig import get_python_lib; print get_python_lib()" /usr/lib/python2.6/dist-packages Within python shell: Python 2.6.5 (r265:79063, Apr 16 2010, 13:09:56) [GCC 4.4.3] on linux2 Type "help", "copyright", "credits" or "license" for more information. >>> import sys >>> print sys.path ['', '/usr/lib/python2.6/dist-packages/django', '/usr/local/lib/python2.6/dist-packages/django/bin', '/usr/local/lib/python2.6/dist-packages/django', '/home/petra/webapps', '/usr/lib/python2.6', '/usr/lib/python2.6/plat-linux2', '/usr/lib/python2.6/lib-tk', '/usr/lib/python2.6/lib-old', '/usr/lib/python2.6/lib-dynload', '/usr/lib/python2.6/dist-packages', '/usr/lib/python2.6/dist-packages/PIL', '/usr/lib/pymodules/python2.6'] django-admin.py can be found here: mx:~/webapps$ locate django-admin.py ~/install/sources/Django-1.2.1/build/lib.linux-i686-2.6/django/bin/django-admin.py ~/install/sources/Django-1.2.1/build/scripts-2.6/django-admin.py ~/install/sources/Django-1.2.1/django/bin/django-admin.py /usr/local/bin/django-admin.py /usr/local/lib/python2.6/dist-packages/django/bin/django-admin.py /usr/local/lib/python2.6/dist-packages/django/bin/django-admin.pyc and in the end this doesn't help: export PYTHONPATH="/usr/lib/python2.6/dist-packages/django:$PYTHONPATH" nor this: export PYTHONPATH="/usr/local/lib/python2.6/dist-packages/django:$PYTHONPATH" How to solve this !? Thanks all in advance! :)

    Read the article

  • gae error : Error: Server Error, how to debut it .

    - by zjm1126
    when i upload my project to google-app-engine , it show this : Error: Server Error The server encountered an error and could not complete your request. If the problem persists, please report your problem and mention this error message and the query that caused it. why ? how can i debug this error ? thanks

    Read the article

  • gae error : Error: Server Error, how to debug it .

    - by zjm1126
    when i upload my project to google-app-engine , it show this : Error: Server Error The server encountered an error and could not complete your request. If the problem persists, please report your problem and mention this error message and the query that caused it. why ? how can i debug this error ? thanks

    Read the article

  • How to change SMP affinity of an IRQ on Ubuntu domU inside Xen XCP?

    - by Alexander Gladysh
    I'd like to change IRQ SMP affinity for reasons, outlined in this question: CPU0 is swamped with eth1 interrupts But I can't — I see Input/output error when I try to write to /proc/irq/*/smp_affinity. Please point me to the HOWTO on the matter. (A formal reference on /proc/irq/*/ would be cool as well.) Gory details: Note that this is a VM inside an Ubuntu-based Xen XCP host. $ uname -a Linux MYHOST 2.6.38-15-virtual #59-Ubuntu SMP Fri Apr 27 16:40:18 UTC 2012 i686 i686 i386 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 11.04 Release: 11.04 Codename: natty $ sudo cat /proc/irq/*/smp_affinity 01 01 01 01 01 80 80 80 80 80 80 40 40 40 40 40 40 20 20 20 20 20 20 10 10 10 10 10 10 08 08 08 08 08 08 04 04 04 04 04 04 02 02 02 02 02 02 01 01 01 01 01 01 Update. The error details: $ N=$(grep -c processor /proc/cpuinfo) $ echo $N 8 $ printf %x $((2**N-1)) ff $ printf %x $((2**N-1)) | sudo tee /proc/irq/*/smp_affinity fftee: /proc/irq/288/smp_affinity: Input/output error tee: /proc/irq/289/smp_affinity: Input/output error tee: /proc/irq/290/smp_affinity: Input/output error tee: /proc/irq/291/smp_affinity: Input/output error tee: /proc/irq/292/smp_affinity: Input/output error tee: /proc/irq/293/smp_affinity: Input/output error tee: /proc/irq/294/smp_affinity: Input/output error tee: /proc/irq/295/smp_affinity: Input/output error tee: /proc/irq/296/smp_affinity: Input/output error tee: /proc/irq/297/smp_affinity: Input/output error tee: /proc/irq/298/smp_affinity: Input/output error tee: /proc/irq/299/smp_affinity: Input/output error tee: /proc/irq/300/smp_affinity: Input/output error tee: /proc/irq/301/smp_affinity: Input/output error tee: /proc/irq/302/smp_affinity: Input/output error tee: /proc/irq/303/smp_affinity: Input/output error tee: /proc/irq/304/smp_affinity: Input/output error tee: /proc/irq/305/smp_affinity: Input/output error tee: /proc/irq/306/smp_affinity: Input/output error tee: /proc/irq/307/smp_affinity: Input/output error tee: /proc/irq/308/smp_affinity: Input/output error tee: /proc/irq/309/smp_affinity: Input/output error tee: /proc/irq/310/smp_affinity: Input/output error tee: /proc/irq/311/smp_affinity: Input/output error tee: /proc/irq/312/smp_affinity: Input/output error tee: /proc/irq/313/smp_affinity: Input/output error tee: /proc/irq/314/smp_affinity: Input/output error tee: /proc/irq/315/smp_affinity: Input/output error tee: /proc/irq/316/smp_affinity: Input/output error tee: /proc/irq/317/smp_affinity: Input/output error tee: /proc/irq/318/smp_affinity: Input/output error tee: /proc/irq/319/smp_affinity: Input/output error tee: /proc/irq/320/smp_affinity: Input/output error tee: /proc/irq/321/smp_affinity: Input/output error tee: /proc/irq/322/smp_affinity: Input/output error tee: /proc/irq/323/smp_affinity: Input/output error tee: /proc/irq/324/smp_affinity: Input/output error tee: /proc/irq/325/smp_affinity: Input/output error tee: /proc/irq/326/smp_affinity: Input/output error tee: /proc/irq/327/smp_affinity: Input/output error tee: /proc/irq/328/smp_affinity: Input/output error tee: /proc/irq/329/smp_affinity: Input/output error tee: /proc/irq/330/smp_affinity: Input/output error tee: /proc/irq/331/smp_affinity: Input/output error tee: /proc/irq/332/smp_affinity: Input/output error tee: /proc/irq/333/smp_affinity: Input/output error tee: /proc/irq/334/smp_affinity: Input/output error tee: /proc/irq/335/smp_affinity: Input/output error Update. irqbalance is running: $ sudo service irqbalance status irqbalance start/running, process 560

    Read the article

  • Reporting System architecture for better performance

    - by pauloya
    Hi, We have a product that runs Sql Server Express 2005 and uses mainly ASP.NET. The database has around 200 tables, with a few (4 or 5) that can grow from 300 to 5000 rows per day and keep a history of 5 years, so they can grow to have 10 million rows. We have built a reporting platform, that allows customers to build reports based on templates, fields and filters. We face performance problems almost since the beginning, we try to keep reports display under 10 seconds but some of them go up to 25 seconds (specially on those customers with long history). We keep checking indexes and trying to improve the queries but we get the feeling that there's only so much we can do. Off course the fact that the queries are generated dynamically doesn't help with the optimization. We also added a few tables that keep redundant data, but then we have the added problem of maintaining this data up to date, and also Sql Express has a limit on the size of databases. We are now facing a point where we have to decide if we want to give up real time reports, or maybe cut the history to be able to have better performance. I would like to ask what is the recommended approach for this kind of systems. Also, should we start looking for third party tools/platforms? I know OLAP can be an option but can we make it work on Sql Server Express, or at least with a license that is cheap enough to distribute to thousands of deployments? Thanks

    Read the article

  • Seeking reporting or templating tool to generate large formatted PDF reports from dataset

    - by Mr. Tacos
    Say I have some data in MySQL or a big ole CSV file. I also have a report. It's a PDF, call it 100 pages long. I need to generate variations on this PDF for slices of the data. More specific example: I have a CSV file with each StackOverflow user in a row and each column contains various statistics about that user. I have a report called "Your StackOverflow Performance". Its got lots of text, always the same, but each section contains something like: "You Vs. The Average StackOverflow Poster on this metric". I want a table that appears there that has the average data, which is the same in every run of the PDF, in one column. In the second column, I want your data, which is different for each PDF/row in the CSV file/user of StackOverflow. I'm pretty sure people use things like Crystal for this? Is there something in MS SQL Server that's good for this? An open source template language? I'm not even really sure if what I need is called a 'reporting' tool (since I don't really need to do any crunching, the data in this case is being crunched by a series of scripts and SPSS, I don't need bands and subbands and so on) or 'templating'. Is there even such a thing as templating PDFs? Natch, I'd be fine with something that generates output easily scriptable to PDF, like eps, but not something like HTML. The report formatting is fussy and done and externally determined and handed down from on high. It's print-oriented, not webby. Thanks in advance.

    Read the article

  • Reporting tool for OLAP, *not* OLTP!

    - by Stefan Moser
    I'm looking for a control that I can put on top of an already existing OLAP star schema to allow the user to define their own "queries" and generate reports. Right now I have some predefined reports built on top of the cubes, but I'd like to allow the user to define their own criteria based on the cubes that I've created. I've found lots of products that will allow you to treat a transactional table like an OLAP cube, but nothing specifically for pre-existing cubes. EDIT: Let me be clear, I know there are countless reporting tools out there that claim to report on OLAP cubes. The problem is they all assume they are looking at transactional data and try to create their own cubes. I have tables that contain tens, if not hundreds of millions of records. Most tools crash when handling this much data, the others just run incredible slowly. I don't want a tool that is targeting the business people. I want a tool that understands what a star and snowflake schema is. I want to be able to tell it what the fact tables are and what the dimension tables are, and then creates a UI on top of them. This is an easier problem to solve for the tool vendor because I am spoon feeding them the cubes. I want to rely on the fact that cubes are a standardized pattern and I want a tool that takes advantage of this fact. I want a tool that targets developers and starts with the assumption that I actually know how to manage my data, it just needs to build pretty reports for me and not crumble under the weight of my data.

    Read the article

  • Question about Reporting and Data Warehousing Software bundled with SQL Server 2005

    - by anonymous user
    We currently use SQL Server 2005 Enterprise for our fairly large application, that has its roots in pre SQL Server 7.0. The tables are normalized and designed mainly for the application. The developers for the most part have the legacy SQL Server mindset. Only using the part of TSQL that existed back in 7.0, not using any of the new features of tsql or that are bundled with 2005. We're currently trying to build on demand reports using some crappy third party software, and will eventually try to build a data warehouse using more of the same crappy third party software (name removed to protect the guilty, don't ask I will not tell). The rationale for this was that we didn't want to spend more money to buy this additional software from Microsoft (this was not my decision, I had no input, but is my problem now). But from what I can tell is that Enterprise includes all of these tools, or am I missing something? What comes bundled with SQL Server 2005 Enterprise as far as reporting and data warehousing? Will we need to purchase anything else? is there actually anything else that can be purchased from Microsoft in this regard?

    Read the article

  • Returning data from SQL Server reporting web service call

    - by user79339
    Hi, I am generating a report that contains the version number. The version number is stored in the DB and retrieved/incremented as part of the report generation. The only problem is, I am calling SSRS via a web service call, which returns the generated report as a byte array. Is there any way to get the version number out of this generated report? For example to display a dialog that says "You generated Status Report, Version number 3". I tried passing in an output parameter and setting it inside the storedproc. Its modified when i execute it in sql management studio, but not in the reporting studio. Or atleast i can't seem to bind to the modified, post execution value (using expression "=Parameters!ReportVersion.Value"). Of course, I could get/increment the version number from database myself before calling the SSRS webservice and pass it along as a parameter to the Report, but that might cause concurrancy problems. On the whole, it just seems neater for the storedproc to access/generate a version number and return it to the ReportingEngine, which will generate the report with the version number and return the updated version number to the WebService client. Any thoughts/Ideas?

    Read the article

  • Reporting Services 2005 - Parameter reliant on cascading parameters

    - by sHr0oMaN
    Good day I have the following: In a SSRS 2005 report I have three report parameters: FinancialPeriodType ("Month" or "Week" in a DropDownList), FinancialPeriod (cascading DropDownList populated depending on first selection) and another parameter, OpeningBalance, of type float. The first two parameters are cascading i.e. the first parameter is used by the query populating the second's available values. This works fine. What I'm attemping to do is default the value of OpeningBalance to a value from a dataset populated by a stored procedure which takes in the first two parameters. However as soon as I select a value for the first parameter, I get the following error: An error occurred during report processing. The value for the report parameter 'OpeningBalance' is not valid for its type.' I've tried setting the default of the second parameter to be a meaningful default (something like 200901) as well as defaulting the second parameter in the SQL store procedure with no affect. Using SQL Profiler I've noticed that selecting a value for the first parameter doesn't even execute the SQL used to obtain available values for the second parameter.

    Read the article

  • Reporting Services Sum of Inner Group in Outer Group

    - by Spoonybard
    I have a report in Reporting Services 2008 using ASP.net 3.5 and SQL Server 2008. The report has 2 groupings and a detail row. This is the current format: Outer Group Inner Group Detail Row The Detail Row represents an item on a receipt and a receipt can have multiple items. Each receipt was paid with a certain payment method. So the Outer Group is grouped by payment type, the Inner Group is grouped by the receipt's ID, and the Detail Row is each item for the given receipt. My raw data result set has two important columns: The Amount Received and the Amount Applied. The Amount Received is how much money in total was collected for all the items on the receipt. The Amount Applied is how much money each item got from the total Amount Received. Sample Result Set: ReceiptID Item ItemID AmountReceived AmountApplied Payment Method ------------------------------------------------------------------------------------------ 1 Book 1 $200.00 $40.00 Cash 1 CD 2 $200.00 $20.00 Cash 1 Software 3 $200.00 $100.00 Cash 1 Backpack 4 $200.00 $40.00 Cash The Inner Group displays the AmountReceived correctly as $200. However, the Outer Group displays the AmountReceived as $800, because I believe that it is going off each detail row which in this case is a count of 4 items. What I want is to see in the Outer Group that the Amount Received is $200. I tried restricting the scope in my SUM function to be the Inner Group, but I get the error "The scope parameter must be set to a string constant that is equal to either the name of a containing group, the name of a containing data region, or the name of a dataset." Does anyone have any suggestions on how to solve this issue? Thanks.

    Read the article

  • Resolving "Error accessing a table..." Error

    Are you encountering an error message during DB2 database startup? Or during the execution of Alter Tablespace SQL command? If ';yes';, then the three possible reasons for the error message are, contai... [Author: Mark Willium - Computers and Internet - May 13, 2010]

    Read the article

  • CUDA linking error - Visual Express 2008 - nvcc fatal due to (null) configuration file

    - by Josh
    Hi, I've been searching extensively for a possible solution to my error for the past 2 weeks. I have successfully installed the Cuda 64-bit compiler (tools) and SDK as well as the 64-bit version of Visual Studio Express 2008 and Windows 7 SDK with Framework 3.5. I'm using windows XP 64-bit. I have confirmed that VSE is able to compile in 64-bit as I have all of the 64-bit options available to me using the steps on the following website: (since Visual Express does not inherently include the 64-bit packages) http://jenshuebel.wordpress.com/2009/02/12/visual-c-2008-express-edition-and-64-bit-targets/ I have confirmed the 64-bit compile ability since the "x64" is available from the pull-down menu under "Tools-Options-VC++ Directories" and compiling in 64-bit does not result in the entire project being "skipped". I have included all the needed directories for 64-bit cuda tools, 64 SDK and Visual Express (\VC\bin\amd64). Here's the error message I receive when trying to compile in 64-bit: 1>------ Build started: Project: New, Configuration: Release x64 ------ 1>Compiling with CUDA Build Rule... 1>"C:\CUDA\bin64\nvcc.exe" -arch sm_10 -ccbin "C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\bin" -Xcompiler "/EHsc /W3 /nologo /O2 /Zi /MT " -maxrregcount=32 --compile -o "x64\Release\template.cu.obj" "c:\Documents and Settings\All Users\Application Data\NVIDIA Corporation\NVIDIA GPU Computing SDK\C\src\CUDA_Walkthrough_DeviceKernels\template.cu" 1>nvcc fatal : Visual Studio configuration file '(null)' could not be found for installation at 'C:/Program Files (x86)/Microsoft Visual Studio 9.0/VC/bin/../..' 1>Linking... 1>LINK : fatal error LNK1181: cannot open input file '.\x64\Release\template.cu.obj' 1>Build log was saved at "file://c:\Documents and Settings\Administrator\My Documents\Visual Studio 2008\Projects\New\New\x64\Release\BuildLog.htm" 1>New - 1 error(s), 0 warning(s) ========== Build: 0 succeeded, 1 failed, 0 up-to-date, 0 skipped ========== Here's the simple code I'm trying to compile/run in 64-bit: #include <stdlib.h> #include <stdio.h> #include <string.h> #include <math.h> #include <cuda.h> void mypause () { printf ( "Press [Enter] to continue . . ." ); fflush ( stdout ); getchar(); } __global__ void VecAdd1_Kernel(float* A, float* B, float* C, int N) { int i = blockDim.x*blockIdx.x+threadIdx.x; if (i<N) C[i] = A[i] + B[i]; //result should be a 16x1 array of 250s } __global__ void VecAdd2_Kernel(float* B, float* C, int N) { int i = blockDim.x*blockIdx.x+threadIdx.x; if (i<N) C[i] = C[i] + B[i]; //result should be a 16x1 array of 400s } int main() { int N = 16; float A[16];float B[16]; size_t size = N*sizeof(float); for(int i=0; i<N; i++) { A[i] = 100.0; B[i] = 150.0; } // Allocate input vectors h_A and h_B in host memory float* h_A = (float*)malloc(size); float* h_B = (float*)malloc(size); float* h_C = (float*)malloc(size); //Initialize Input Vectors memset(h_A,0,size);memset(h_B,0,size); h_A = A;h_B = B; printf("SUM = %f\n",A[1]+B[1]); //simple check for initialization //Allocate vectors in device memory float* d_A; cudaMalloc((void**)&d_A,size); float* d_B; cudaMalloc((void**)&d_B,size); float* d_C; cudaMalloc((void**)&d_C,size); //Copy vectors from host memory to device memory cudaMemcpy(d_A,h_A,size,cudaMemcpyHostToDevice); cudaMemcpy(d_B,h_B,size,cudaMemcpyHostToDevice); //Invoke kernel int threadsPerBlock = 256; int blocksPerGrid = (N+threadsPerBlock-1)/threadsPerBlock; VecAdd1(blocksPerGrid, threadsPerBlock,d_A,d_B,d_C,N); VecAdd2(blocksPerGrid, threadsPerBlock,d_B,d_C,N); //Copy results from device memory to host memory //h_C contains the result in host memory cudaMemcpy(h_C,d_C,size,cudaMemcpyDeviceToHost); for(int i=0; i<N; i++) //output result from the kernel "VecAdd" { printf("%f ", h_C[i] ); printf("\n"); } printf("\n"); cudaFree(d_A); cudaFree(d_B); cudaFree(d_C); free(h_A); free(h_B); free(h_C); mypause(); return 0; }

    Read the article

  • How to debug manifest errors?

    - by Rryk
    I am creating an application that depends on third-party library, which in turn depends on MSVCP90D.dll (it was compiled with debug symbols). While starting the application it fails to start and provides an error message: I have found such library in C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\redist\Debug_NonRedist\amd64\Microsoft.VC90.DebugCRT and C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\redist\Debug_NonRedist\x86\Microsoft.VC90.DebugCRT. As you can see one of them is 64-bit, while the other is 32-bit. When I have placed 32-bit into the directory of the application the application silently crashes while loading (log from Visual Studio Output window is below). With the 32-bit one I get another error message: If I press Abort -- programs shuts down, Retry results in breaking into debug session for crt0msg.c file. This is system file and I have no idea how to debug it. If I press Ignore I get yet another error message: So the question is how to debug such errors? Please give me some links where I can read more about it or point me out what exactly I should do in such cases. I know this relates to manifest problems -- please give me a good resource where I can read about resources, since what I have found have confused me even more. This is log for 64-bit version of the MSVCP90D.dll library: 'chrome.exe': Loaded 'D:\Projects\Chromium\devenv\install\build-msvc-debug\chromium-xml3d-rtsg2\chrome.exe', Symbols loaded. 'chrome.exe': Loaded 'C:\Windows\SysWOW64\ntdll.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\kernel32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\KernelBase.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\user32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\gdi32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\lpk.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\usp10.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\msvcrt.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\advapi32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\sechost.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\rpcrt4.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\sspicli.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\cryptbase.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\shell32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\shlwapi.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\winmm.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\version.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\psapi.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\imm32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\msctf.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'D:\Projects\Chromium\devenv\install\build-msvc-debug\chromium-xml3d-rtsg2\chrome.dll', Symbols loaded. 'chrome.exe': Loaded 'C:\Windows\SysWOW64\ole32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\oleaut32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\winsxs\x86_microsoft.windows.common-controls_6595b64144ccf1df_6.0.7600.16385_none_421189da2b7fabfc\comctl32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\oleacc.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\opengl32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\glu32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\ddraw.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\dciman32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\setupapi.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\cfgmgr32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\devobj.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\dwmapi.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'C:\Windows\SysWOW64\secur32.dll', Symbols loaded (source information stripped). 'chrome.exe': Loaded 'D:\Projects\Chromium\devenv\install\build-msvc-debug\rtsg2\bin\RTSG2.dll', Symbols loaded. 'chrome.exe': Unloaded 'D:\Projects\Chromium\devenv\install\build-msvc-debug\chromium-xml3d-rtsg2\chrome.dll' 'chrome.exe': Unloaded 'D:\Projects\Chromium\devenv\install\build-msvc-debug\rtsg2\bin\RTSG2.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\secur32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\opengl32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\ddraw.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\dwmapi.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\setupapi.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\devobj.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\cfgmgr32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\dciman32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\glu32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\oleacc.dll' 'chrome.exe': Unloaded 'C:\Windows\winsxs\x86_microsoft.windows.common-controls_6595b64144ccf1df_6.0.7600.16385_none_421189da2b7fabfc\comctl32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\oleaut32.dll' 'chrome.exe': Unloaded 'C:\Windows\SysWOW64\ole32.dll' 'chrome.exe': Loaded 'C:\Windows\SysWOW64\ole32.dll', Symbols loaded (source information stripped). The program '[1152] chrome.exe: Native' has exited with code 9 (0x9).

    Read the article

  • Error LNK1223 on ARM builds

    - by Seva Alekseyev
    eMbedded Visual C++ 3 project, building for PocketPC 2000. On the ARM build, the linker throws the following error: fatal error LNK1223: invalid or corrupt file: file contains invalid pdata contributions On SH3, the project compiles, links, and works. The project also works when built for ARM on Visual C++ 2005, but I need to test builds specifically from eVC3. Any ideas, please? What's a pdata contribution and how do I affect (or disable) those? It's something to do with exception handling; I've tried disabling SEH by specifying /EHsc, to no effect.

    Read the article

  • Windows 2008 R2 SMB / CIFS Logging to diagnose Brother MFC Network Scanning

    - by Steven Potter
    I am attempting to setup network scanning on a brother MFC-9970CDW printer. According to the Brother documentation, the printer is setup to connect to any CIFS network share. I applied all of the appropriate setting in the printer however I get a "sending error" when I try to scan a document. When I look at the logs of the 2008 R2 server that I am attempting to connect to; I can see in the security log where the printer successfully authenticates, however nothing else is logged. I would assume that immediately after the authentication, the printer is making a CIFS request and some sort of error is occurring, however I can't seem to find any way to log this information to find out what is going on. Is it possible to get Windows 2008 to log SMB/CIFS traffic? Followup: I installed Microsoft netmon and captured the packets associated with the transaction: 510 3:04:28 PM 7/9/2012 34.4277743 System 192.168.1.134 192.168.1.10 SMB SMB:C; Negotiate, Dialect = NT LM 0.12 {SMBOverTCP:30, TCP:29, IPv4:22} 511 3:04:28 PM 7/9/2012 34.4281246 System 192.168.1.10 192.168.1.134 SMB SMB:R; Negotiate, Dialect is NT LM 0.12 (#0), SpnegoToken (1.3.6.1.5.5.2) {SMBOverTCP:30, TCP:29, IPv4:22} 519 3:04:29 PM 7/9/2012 34.8986214 System 192.168.1.134 192.168.1.10 SMB SMB:C; Session Setup Andx, NTLM NEGOTIATE MESSAGE {SMBOverTCP:30, TCP:29, IPv4:22} 520 3:04:29 PM 7/9/2012 34.8989310 System 192.168.1.10 192.168.1.134 SMB SMB:R; Session Setup Andx, NTLM CHALLENGE MESSAGE - NT Status: System - Error, Code = (22) STATUS_MORE_PROCESSING_REQUIRED {SMBOverTCP:30, TCP:29, IPv4:22} 522 3:04:29 PM 7/9/2012 34.9022870 System 192.168.1.134 192.168.1.10 SMB SMB:C; Session Setup Andx, NTLM AUTHENTICATE MESSAGEVersion:v2, Domain: CORP, User: PRINTSUPOFF, Workstation: BRN001BA9AD1FE6 {SMBOverTCP:30, TCP:29, IPv4:22} 523 3:04:29 PM 7/9/2012 34.9032421 System 192.168.1.10 192.168.1.134 SMB SMB:R; Session Setup Andx {SMBOverTCP:30, TCP:29, IPv4:22} 525 3:04:29 PM 7/9/2012 34.9051855 System 192.168.1.134 192.168.1.10 SMB SMB:C; Tree Connect Andx, Path = \\192.168.1.10\IPC$, Service = ????? {SMBOverTCP:30, TCP:29, IPv4:22} 526 3:04:29 PM 7/9/2012 34.9053083 System 192.168.1.10 192.168.1.134 SMB SMB:R; Tree Connect Andx, Service = IPC {SMBOverTCP:30, TCP:29, IPv4:22} 528 3:04:29 PM 7/9/2012 34.9073573 System 192.168.1.134 192.168.1.10 DFSC DFSC:Get DFS Referral Request, FileName: \\192.168.1.10\NSCFILES, MaxReferralLevel: 3 {SMB:33, SMBOverTCP:30, TCP:29, IPv4:22} 529 3:04:29 PM 7/9/2012 34.9152042 System 192.168.1.10 192.168.1.134 SMB SMB:R; Transact2, Get Dfs Referral - NT Status: System - Error, Code = (549) STATUS_NOT_FOUND {SMB:33, SMBOverTCP:30, TCP:29, IPv4:22} 531 3:04:29 PM 7/9/2012 34.9169738 System 192.168.1.134 192.168.1.10 SMB SMB:C; Tree Disconnect {SMBOverTCP:30, TCP:29, IPv4:22} 532 3:04:29 PM 7/9/2012 34.9170688 System 192.168.1.10 192.168.1.134 SMB SMB:R; Tree Disconnect {SMBOverTCP:30, TCP:29, IPv4:22} As you can see, the DFS referral fails and the transaction is shut down. I can't see any reason for the DFS referral to fail. The only reference I can find online is: https://bugzilla.samba.org/show_bug.cgi?id=8003 Anyone have any ideas for a solution?

    Read the article

  • Fatal Error when using ADODB in VB6 on Windows Server 2003 SP2

    - by m.edmondson
    We've got a legacy app (VB6) which works fine on an old Windows Server 2003 box and has been for many years. Recently we've had to move it to a different physical location and in doing this we cloned the box with virtualisation and placed it elsewhere. In theory these two environments should be identical. On the new box however the app falls over when calling the RecordCount method of an ADODB.Recordset. I should say that I can successfully read the ADODB.RecordSet.Properties.Count property with no problem on the line before. The event viewer reports the following: Event Type: Error Event Source: Application Error Event Category: (100) Event ID: 1000 Date: 28/09/2012 Time: 11:15:27 User: N/A Computer: APP01 Description: Faulting application Control.exe, version 1.0.0.6, faulting module ntdll.dll, version 5.2.3790.4789, fault address 0x0002c6e4. I can only imagine there is something wrong with using ADODB within a virtualised environment. Any ideas?

    Read the article

< Previous Page | 75 76 77 78 79 80 81 82 83 84 85 86  | Next Page >