Search Results

Search found 59257 results on 2371 pages for 'windows identity'.

Page 794/2371 | < Previous Page | 790 791 792 793 794 795 796 797 798 799 800 801  | Next Page >

  • IIS is not accepting connections after WIndows system update

    - by user78102
    I've been running a web site for the past year on Windows Home Server 2008 R2. After the March 2012 system updates, the site is no longer accessible to clients. They see this error: website is online but isn't accepting connections. Ping tests to the FQDN of the server are successful and NSLOOKUP returns the correct result. The Internet connection tests out good from the server. I have not changed my internet connection (Comcast Business Internet) or my router configuration (I forward incoming requests from the outside to port 80 of the local IP address of the server). I have tried: Disabling the Windows Firewall. Rebuilding the OS and configuration. I still have the problem. How can I resolve this?

    Read the article

  • Virtualizing Windows with VT-d to play within it

    - by Bahaïka
    I would like to know if what I want to is possible. First, here is my hardware configuration : MB : Gigabyte H77-DS3H Intel Core i5 3330 (3.00GHz) MSI Nvidia GTX 760 8 Gb RAM 1333 MHz What I want to do is to have a linux (probably ArchLinux) as a main and unique OS on my computer (I don't want a dualboot). And virtualizing Windows under Linux. I've read about VT-d (supported by my CPU) and PCIBackHide. I'd like to know if I can initialize Linux with the Integrated Graphics and Virtualize Windows to use the GTX 760. If I can do it, where do I have to plug my two screens ? On the MainBoard or the GTX 760 ? How do I achive that idea ?

    Read the article

  • Windows API Error 2 when installing MikTex (Win7)

    - by GreenAsJade
    I am trying to install MikTex 2.9.3927 on Windows 7 x64. Very early in the installation process, I get a MikTex setup wizard error saying: "Windows API Error 2: The system cannot find the file specified Details: C:...\somefile.tpm" The file that results in the error seems to be different every time I try. I have tried many different installation paths, with many different setup options. The same error occurs if I download the ~138MB "Basic MiKTeX 2.9" Installer or if I use the Net Installer to download the entire setup (~1GB). Note that this is a duplicate question - the other copy of this question is closed to users of under 10 rep. I have asked it so that I can provide an updated answer...

    Read the article

  • MSBuild: TlbImp error since upgrading to VS 2010

    - by floele
    Hi, since upgrading my project to VS2010, including the use of MSBuild v4 instead of 3.5 (and not making any other changes), I get the following build error and have no clue how to fix it (log from CC.NET): <target name="ResolveComReferences" success="false"> <message level="high"><![CDATA[C:\Programme\Microsoft SDKs\Windows\v7.0A\bin\TlbImp.exe c:\Assemblies\NMSDVDXU.dll /namespace:NMSDVDXLib /machine:X64 /out:obj\x64\Release\Interop.NMSDVDXLib.dll /sysarray /transform:DispRet /reference:c:\Assemblies\Bass.Net.dll /reference:c:\Assemblies\LogicNP.FileView.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\mscorlib.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Data.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Design.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Drawing.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Management.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Windows.Forms.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Xml.dll /reference:C:\WINDOWS\assembly\GAC\stdole\7.0.3300.0__b03f5f7f11d50a3a\stdole.dll ]]></message> <error code="TI0000" file="TlbImp"><![CDATA[A single valid machine type compatible with the input type library must be specified.]]></error> <warning code="MSB3283" file="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets" line="1558" column="9"><![CDATA[Die Wrapperassembly für die Typbibliothek "NMSDVDXLib" wurde nicht gefunden.]]></warning> <message level="high"><![CDATA[C:\Programme\Microsoft SDKs\Windows\v7.0A\bin\TlbImp.exe c:\Assemblies\StarBurnX12.dll /namespace:RocketDivision.StarBurnX /machine:X64 /out:obj\x64\Release\Interop.RocketDivision.StarBurnX.dll /sysarray /transform:DispRet /reference:c:\Assemblies\Bass.Net.dll /reference:c:\Assemblies\LogicNP.FileView.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\mscorlib.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Data.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Design.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Drawing.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Management.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Windows.Forms.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Xml.dll /reference:C:\WINDOWS\assembly\GAC\stdole\7.0.3300.0__b03f5f7f11d50a3a\stdole.dll ]]></message> <error code="TI0000" file="TlbImp"><![CDATA[A single valid machine type compatible with the input type library must be specified.]]></error> <warning code="MSB3283" file="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets" line="1558" column="9"><![CDATA[Die Wrapperassembly für die Typbibliothek "RocketDivision.StarBurnX" wurde nicht gefunden.]]></warning> </target> Problem: A single valid machine type compatible with the input type library must be specified. It only applies to the x64 build of my project, x86 still works fine. Apparently, it tries to build a x64 interop assembly from the x86 DLL located in "C:\Assemblies". When executing the TlbImp command with the x64 DLL which is located in a different directory, it works fine. However, I don't know how I can configure my project to use different COM references for the x86 and x64 build. The OS on which the project is being compiled is WinXP x86. Building worked fine when using VS2005 + MSBuild 3.5 Any help would be highly appreciated. I tried building the upgraded project with MSBuild v3.5, but that doesn't work either. It complains about unknown NoWarn codes (probably new in 4.0).

    Read the article

  • How to get around batch file processing limit

    - by Patrick Cuff
    I have a Windows batch file that processes all the files in a given directory. I have 206,783 files I need to process: for %%f in (*.xml) do call :PROCESS %%f goto :STOP :PROCESS :: do something with the file program.exe %1 > %1.new set /a COUNTER=%COUNTER%+1 goto :EOF :STOP @echo %COUNTER% files processed When I run the batch file, the following output is written: 65535 files processed As part of the processing, an output file is created for each file procesed, with a .new extension. When I do a dir *.new it reports 65,535 files exist. So, it appears my command environment has a hard limit on the number of files it can recognize, and that limit is 64K - 1. Is there a way to extend the command environment to manage more than 64K - 1 files? If not, would a VBScript or JavaScript be able to process all 206,783 files? I'm running on Windows 2003 server, Enterprise Edition, 32-bit. UPDATE It looks like the root cause of my issue was with the built-in Windows "extract" command for ZIP files. The files I have to process were copied from another system via a ZIP file. My server doesn't have a ZIP utility installed, just the native Windows commands. I right-clicked on the ZIP file, and did an "Extract all...", which apparently just extracted the first 65,535 files. I downloaded and installed 7-zip onto my server, unzipped all the files, and my batch script worked as intended.

    Read the article

  • Problem with creation of scheduled task from IIS6 on SR2003

    - by Morten Louw Nielsen
    Hi, I am writing a webapplication using .NET. The webapp creates scheduled tasks using the System.Diagnostics.Process class, calling SCHTASKS.EXE with parameters. I have changed the identity on the app pool, to a specific domain user. The domain-user is local administrator on all the four webservers. From webserver01 I am creating tasks on webserver01 to webserver04. It works perfect for 3-5 days, but then it breaks. It gives me the following errormessage in a messagebox: "The application failed to initialize properly (0xc0000142). Click on OK to terminate the application." If I have the system in the broken state, and I change the identity of the app pool to Domain administrator, it works. As I change it back to my domain-user, it breaks again. If I reboot the server, it works again for the same amount of days, but will break again. It seems like a permission-related problem. I just don't understand why it works sometimes, and sometimes doesn't. I hope someone outthere has seen this problem! Looking forward to hear from you! Kind regards, Morten, Denmark

    Read the article

  • eventmachine and external scripts via backticks

    - by Maciek
    I have a small HTTP server script I've written using eventmachine which needs to call external scripts/commands and does so via backticks (``). When serving up requests which don't run backticked code, everything is fine, however, as soon as my EM code executes any backticked external script, it stops serving requests and stops executing in general. I noticed eventmachine seems to be sensitive to sub-processes and/or threads, and appears to have the popen method for this purpose, but EM's source warns that this method doesn't work under Windows. Many of the machines running this script are running Windows, so I can't use popen. Am I out of luck here? Is there a safe way to run an external command from an eventmachine script under Windows? Is there any way I could fire off some commands to be run externally without blocking EM's execution? edit: the culprit that seems to be screwing up EM the most is my usage of the Windows start command, as in: start java myclass. The reason I'm using start is because I want those external scripts to start running and keep running after the EM request is served

    Read the article

  • Accesing WinCE ComboBox DroppedDown property (.NET CF 2.0)

    - by PabloG
    I'm implementing custom behavior sub-classing the form controls, but I cannot manage to access the DroppedDown property of the ComboBox. Looking in the help, it's supposed to be supported in CF.NET 2.0: using System; using System.Collections.Generic; using System.ComponentModel; using System.Drawing; using System.Data; using System.Text; using System.Windows.Forms; namespace xCustomControls { public partial class xComboBox : System.Windows.Forms.ComboBox { private ComboBox comboBox1; public xComboBox() { InitializeComponent(); this.KeyDown += new KeyEventHandler(this.KeyDownHandler); } private void KeyDownHandler(object sender, KeyEventArgs e) { // DroppedDown doesn't appear in the IntelliSense of ComboBox. // or this.comboBox1. if (((ComboBox)sender).DroppedDown) // fail! return; switch (e.KeyData) { case Keys.Up: case Keys.Enter: case Keys.Down: e.Handled = true; this.Parent.SelectNextControl((Control)sender, e.KeyData != Keys.Up, true, true, true); ... fails with 'System.Windows.Forms.ComboBox' does not contain a definition for 'DroppedDown' and no extension method 'DroppedDown' accepting a first argument of type 'System.Windows.Forms.ComboBox' could be found How can I access the property? TIA, Pablo

    Read the article

  • Malware - Technical anlaysis

    - by nullptr
    Note: Please do not mod down or close. Im not a stupid PC user asking to fix my pc problem. I am intrigued and am having a deep technical look at whats going on. I have come across a Windows XP machine that is sending unwanted p2p traffic. I have done a 'netstat -b' command and explorer.exe is sending out the traffic. When I kill this process the traffic stops and obviously Windows Explorer dies. Here is the header of the stream from the Wireshark dump (x.x.x.x) is the machines IP. GNUTELLA CONNECT/0.6 Listen-IP: x.x.x.x:8059 Remote-IP: 76.164.224.103 User-Agent: LimeWire/5.3.6 X-Requeries: false X-Ultrapeer: True X-Degree: 32 X-Query-Routing: 0.1 X-Ultrapeer-Query-Routing: 0.1 X-Max-TTL: 3 X-Dynamic-Querying: 0.1 X-Locale-Pref: en GGEP: 0.5 Bye-Packet: 0.1 GNUTELLA/0.6 200 OK Pong-Caching: 0.1 X-Ultrapeer-Needed: false Accept-Encoding: deflate X-Requeries: false X-Locale-Pref: en X-Guess: 0.1 X-Max-TTL: 3 Vendor-Message: 0.2 X-Ultrapeer-Query-Routing: 0.1 X-Query-Routing: 0.1 Listen-IP: 76.164.224.103:15649 X-Ext-Probes: 0.1 Remote-IP: x.x.x.x GGEP: 0.5 X-Dynamic-Querying: 0.1 X-Degree: 32 User-Agent: LimeWire/4.18.7 X-Ultrapeer: True X-Try-Ultrapeers: 121.54.32.36:3279,173.19.233.80:3714,65.182.97.15:5807,115.147.231.81:9751,72.134.30.181:15810,71.59.97.180:24295,74.76.84.250:25497,96.234.62.221:32344,69.44.246.38:42254,98.199.75.23:51230 GNUTELLA/0.6 200 OK So it seems that the malware has hooked into explorer.exe and hidden its self quite well as a Norton Scan doesn't pick anything up. I have looked in Windows firewall and it shouldn't be letting this traffic through. I have had a look into the messages explorer.exe is sending in Spy++ and the only related ones I can see are socket connections etc... My question is what can I do to look into this deeper? What does malware achieve by sending p2p traffic? I know to fix the problem the easiest way is to reinstall Windows but I want to get to the bottom of it first, just out of interest.

    Read the article

  • Problem detecting installed application on Win Svr 2003 x64

    - by PD
    I have an x86 Windows application that consists of a couple of services and a client ui. Due to various issues with persuading the various MSIs to upgrade properly, the installation process is now governed by a wizard-style program that detects what is currently installed and handles upgrades by storing the user's current settings, uninstalling the existing software and installing the new version(s). The basic process is: Look in HKLM\Software\Classes\Installer\Products Loop through the GUID keys therein looking for ProductName="(my app name)" If not found, repeat starting from HKCU\Software\Microsoft\Installer\Products instead If found, offer the user an upgrade (as described earlier) else a clean install (i.e. user is asked various questions by the wizard) Now, this works just fine on pretty much any Windows platform you care to mention, from XP up. It fails only on Windows Server 2003 x64, in that an existing installation is not detected by the wizard - despite the exact same registry keys being present as are on any other platform I test on. It's fine on: XP x32 Vista x32, x64 Server 2003 x86 Server 2008 x86, x64 Server 2008 R2 x64 Windows 7 x86, x64 It's only Server 2003 x64 that seems to exhibit this issue.

    Read the article

  • Where should I store shared resources between LocalSystem and regular user with UAC?

    - by rwired
    My application consists of two parts: A Windows Service running under the LocalSystem account and a client process running under the currently logged in regular user. I need to deploy the application across Windows versions from XP up to Win7. The client will retrieve files from the web and collect user data from the user. The service will construct files and data of it's own which the client needs to read. I'm trying to figure out the best place (registry or filesystem, or mix) to store all this. One file the client or service needs to be able to retrieve from the net is an update_patch executable which needs to run whenever an upgrade is available. I need to be sure the initial installer SETUP.EXE, and also the update_patch can figure out this ideal location and set a RegKey to be read later by both client and server telling them the magic location (The SETUP.EXE will run with elevated privileges since it needs to install the service) On my Win7 test system the service %APPDATA% points to: C:\Windows\system32\config\systemprofile\AppData\Roaming and the %APPDATA% of the client points to: C:\Users\(username)\AppData\Roaming Interestingly Google Chrome stores everything (App and Data) in C:\Users\(username)\AppData\Local\Google\Chrome Chrome runs pretty much in exactly the way I want my suite to run (able to silently update itself in the background) What I'm trying to avoid is nasty popups warning the user that the app wants to modify the system, and I want to avoid problems when VirtualStore doesn't exist because the user is running XP/2000/2003 or has UAC turned off. My target audience are non-tech-savvy general Windows users.

    Read the article

  • How to optimize paging for large in memory database

    - by snakefoot
    I have an application where the entire database is implemented in memory using a stl-map for each table in the database. Each item in the stl-map is a complex object with references to other items in the other stl-maps. The application works with a large amount of data, so it uses more than 500 MByte RAM. Clients are able to contact the application and get a filtered version of the entire database. This is done by running through the entire database, and finding items relevant for the client. When the application have been running for an hour or so, then Windows 2003 SP2 starts to page out parts of the RAM for the application (Eventhough there is 16 GByte RAM on the machine). After the application have been partly paged out then a client logon takes a long time (10 mins) because it now generates a page fault for each pointer lookup in the stl-map. I can see it is possible to tell Windows to lock memory in RAM, but this is generally only recommended for device drivers, and only for "small" amounts of memory. I guess a poor mans solution could be to loop through the entire memory database, and thus tell Windows we are still interested in keeping the datamodel in RAM. I guess another poor mans solution could be to disable the pagefile completely on Windows. I guess the expensive solution would be a SQL database, and then rewrite the entire application to use a database layer. Then hopefully the database system will have implemented means to for fast access. Are there other more elegant solutions ?

    Read the article

  • Sharing a global/static variable between a process and DLL

    - by minjang
    I'd like to share a static/global variable only between a process and a dll that is invoked by the process. The exe and dll are in the same memory address space. I don't want the variable to be shared among other processes. Elaboration of the problem: Say that there is a static/global variable x in a.cpp. Both the exe foo.exe and the dll bar.dll have a.cpp, so the variable x is in both images. Now, foo.exe dynamically loads (or statically) bar.dll. Then, the problem is whether the variable x is shared by the exe and dll, or not. In Windows, these two guys never share the x: the exe and dll will have a separate copy of x. However, in Linux, the exe and dll do share the variable x. Unfortunately, I want the behavior of Linux. I first considered using pragma data_seg on Windows. However, even if I correctly setup the shared data segment, foo.exe and bar.dll never shares the x. Recall that bar.dll is loaded into the address space of foo.exe. However, if I run another instance of foo.exe, then x is shared. But, I don't want x to be shared by different processes. So, using data_seg was failed. I may it use a memory-mapped file by making an unique name between exe and dll, which I'm trying now. Two questions: Why the behavior of Linux and Windows is different? Can anyone explain more about this? What would be most easiest way to solve this problem on Windows?

    Read the article

  • How to avoid mouse move on Touch

    - by VirtualBlackFox
    I have a WPF application that is capable of being used both with a mouse and using Touch. I disable all windows "enhancements" to just have touch events : Stylus.IsPressAndHoldEnabled="False" Stylus.IsTapFeedbackEnabled="False" Stylus.IsTouchFeedbackEnabled="False" Stylus.IsFlicksEnabled="False" The result is that a click behave like I want except on two points : The small "touch" cursor (little white star) appears where clicked an when dragging. Completely useless as the user finger is already at this location no feedback is required (Except my element potentially changing color if actionable). Elements stay in the "Hover" state after the movement / Click ends. Both are the consequences of the fact that while windows transmit correctly touch events, he still move the mouse to the last main-touch-event. I don't want windows to move the mouse at all when I use touch inside my application. Is there a way to completely avoid that? Notes: Handling touch events change nothing to this. Using SetCursorPos to move the mouse away make the cursor blink and isn't really user-friendly. Disabling the touch panel to act as an input device completely disable all events (And I also prefer an application-local solution, not system wide). I don't care if the solution involve COM/PInvoke or is provided in C/C++ i'll translate. If it is necessary to patch/hook some windows dlls so be it, the software will run on a dedicated device anyway. I'm investigating the surface SDK but I doubt that it'll show any solution. As a surface is a pure-touch device there is no risk of bad interaction with the mouse.

    Read the article

  • Why "Content-Length: 0" in POST requests?

    - by stesch
    A customer sometimes sends POST requests with Content-Length: 0 when submitting a form (10 to over 40 fields). We tested it with different browsers and from different locations but couldn't reproduce the error. The customer is using Internet Explorer 7 and a proxy. We asked them to let their system administrator see into the problem from their side. Running some tests without the proxy, etc.. In the meantime (half a year later and still no answer) I'm curious if somebody else knows of similar problems with a Content-Length: 0 request. Maybe from inside some Windows network with a special proxy for big companies. Is there a known problem with Internet Explorer 7? With a proxy system? The Windows network itself? Google only showed something in the context of NTLM (and such) authentication, but we aren't using this in the web application. Maybe it's in the way the proxy operates in the customer's network with Windows logins? (I'm no Windows expert. Just guessing.) I have no further information about the infrastructure.

    Read the article

  • PowerShell Code Snippets for SharePoint2010 Developers

    - by ybbest
    Install solution to SharePoint Farm and activate Feature to a site collection #Please specify the solution package path. $SolutionPackagePath = “C:\ybbest\myForm.xsn” Add-SPSolution -LiteralPath $SolutionPackagePath #Please specify the site collection url. $SiteCollectionUrl=”http:// ybbest /” # Install the solution package to the SharePoint Farm Install-SPSolution -Identity ybbest.wsp -GACDeployment #Activate features in the solution package to a Site Collection Enable-SPFeature -Identity 8ed800a2-3494-4cba-adf1-ed8714cb062d -Url $SiteCollectionUrl Retract solution from SharePoint Farm and deactivate Feature to a site collection #Deactivate features from a Site Collection Disable-SPFeature -Identity 8ed800a2-3494-4cba-adf1-ed8714cb062d -Url http:// ybbest / # Uninstall the solution package to the SharePoint Farm Uninstall-SPSolution -Identity ybbest.wsp # Remove the solution package to the SharePoint Farm Remove-SPSolution -Identity ybbest.wsp Install Admin Approved InfoPath form #Please specify the template path. $InfopathFormTemplatePath = “C:\ybbest\myForm.xsn” #Please specify the site collection url. $SiteCollectionUrl=”http:// ybbest /” #Install InfoPath to the SharePoint Farm $formTemplate=Install-SPInfoPathFormTemplate -Path $InfopathFormTemplatePath #Activate InfoPath form to Site Collection Enable-SPInfoPathFormTemplate -Identity $formTemplate -Site $SiteCollectionUrl References http://technet.microsoft.com/en-us/library/ee806878.aspx http://www.wssdemo.com/Lists/PowerShell/Commands.aspx

    Read the article

  • Can't ssh to instance

    - by megas
    I have a linode instance, I was successfully connecting to it via ssh. But I've decided to rebuild my instance and then I can not connect to that instance via ssh. The linode works correctly because I can get access via Lish (lonode ssh) I've tried to clear known_hosts with: ssh-keygen -R 212.71.xxx.xx But I still getting message: ssh [email protected] -v OpenSSH_5.9p1 Debian-5ubuntu1.1, OpenSSL 1.0.1 14 Mar 2012 debug1: Reading configuration data /etc/ssh/ssh_config debug1: /etc/ssh/ssh_config line 19: Applying options for * debug1: Connecting to 212.71.238.74 [212.71.238.74] port 22. debug1: Connection established. debug1: identity file /home/megas/.ssh/id_rsa type 1 debug1: Checking blacklist file /usr/share/ssh/blacklist.RSA-2048 debug1: Checking blacklist file /etc/ssh/blacklist.RSA-2048 debug1: identity file /home/megas/.ssh/id_rsa-cert type -1 debug1: identity file /home/megas/.ssh/id_dsa type -1 debug1: identity file /home/megas/.ssh/id_dsa-cert type -1 debug1: identity file /home/megas/.ssh/id_ecdsa type -1 debug1: identity file /home/megas/.ssh/id_ecdsa-cert type -1 debug1: Remote protocol version 2.0, remote software version OpenSSH_5.9p1 Debian-5ubuntu1.1 debug1: match: OpenSSH_5.9p1 Debian-5ubuntu1.1 pat OpenSSH* debug1: Enabling compatibility mode for protocol 2.0 debug1: Local version string SSH-2.0-OpenSSH_5.9p1 Debian-5ubuntu1.1 debug1: SSH2_MSG_KEXINIT sent debug1: SSH2_MSG_KEXINIT received debug1: kex: server->client aes128-ctr hmac-md5 none debug1: kex: client->server aes128-ctr hmac-md5 none debug1: sending SSH2_MSG_KEX_ECDH_INIT debug1: expecting SSH2_MSG_KEX_ECDH_REPLY debug1: Server host key: ECDSA c5:c3:a7:c0:5a:25:a1:64:c4:04:0c:42:bb:46:f6:96 debug1: Host '212.71.238.74' is known and matches the ECDSA host key. debug1: Found key in /home/megas/.ssh/known_hosts:1 debug1: ssh_ecdsa_verify: signature correct debug1: SSH2_MSG_NEWKEYS sent debug1: expecting SSH2_MSG_NEWKEYS debug1: SSH2_MSG_NEWKEYS received debug1: Roaming not allowed by server debug1: SSH2_MSG_SERVICE_REQUEST sent debug1: SSH2_MSG_SERVICE_ACCEPT received debug1: Authentications that can continue: publickey,password debug1: Next authentication method: publickey debug1: Offering RSA public key: /home/megas/.ssh/id_rsa debug1: Authentications that can continue: publickey,password debug1: Trying private key: /home/megas/.ssh/id_dsa debug1: Trying private key: /home/megas/.ssh/id_ecdsa debug1: No more authentication methods to try. Permission denied (publickey,password). How to resolve this problem? Thanks

    Read the article

  • How can I reliably check client identity whilst making DCOM calls to a C# .Net 3.5 Server?

    - by pionium
    Hi, I have an old Win32 C++ DCOM Server that I am rewriting to use C# .Net 3.5. The client applications sit on remote XP machines and are also written in C++. These clients must remain unchanged, hence I must implement the interfaces on new .Net objects. This has been done, and is working successfully regarding the implementation of the interfaces, and all of the calls are correctly being made from the old clients to the new .Net objects. However, I'm having problems obtaining the identity of the calling user from the DCOM Client. In order to try to identify the user who instigated the DCOM call, I have the following code on the server... [DllImport("ole32.dll")] static extern int CoImpersonateClient(); [DllImport("ole32.dll")] static extern int CoRevertToSelf(); private string CallingUser { get { string sCallingUser = null; if (CoImpersonateClient() == 0) { WindowsPrincipal wp = System.Threading.Thread.CurrentPrincipal as WindowsPrincipal; if (wp != null) { WindowsIdentity wi = wp.Identity as WindowsIdentity; if (wi != null && !string.IsNullOrEmpty(wi.Name)) sCallingUser = wi.Name; } if (CoRevertToSelf() != 0) ReportWin32Error("CoRevertToSelf"); } else ReportWin32Error("CoImpersonateClient"); return sCallingUser; } } private static void ReportWin32Error(string sFailingCall) { Win32Exception ex = new Win32Exception(); Logger.Write("Call to " + sFailingCall + " FAILED: " + ex.Message); } When I get the CallingUser property, the value returned the first few times is correct and the correct user name is identified, however, after 3 or 4 different users have successfully made calls (and it varies, so I can't be more specific), further users seem to be identified as users who had made earlier calls. What I have noticed is that the first few users have their DCOM calls handled on their own thread (ie all calls from a particular client are handled by a single unique thread), and then subsequent users are being handled by the same threads as the earlier users, and after the call to CoImpersonateClient(), the CurrentPrincipal matches that of the initial user of that thread. To Illustrate: User Tom makes DCOM calls which are handled by thread 1 (CurrentPrincipal correctly identifies Tom) User Dick makes DCOM calls which are handled by thread 2 (CurrentPrincipal correctly identifies Dick) User Harry makes DCOM calls which are handled by thread 3 (CurrentPrincipal correctly identifies Harry) User Bob makes DCOM calls which are handled by thread 3 (CurrentPrincipal incorrectly identifies him as Harry) As you can see in this illustration, calls from clients Harry and Bob are being handled on thread 3, and the server is identifying the calling client as Harry. Is there something that I am doing wrong? Are there any caveats or restrictions on using Impersonations in this way? Is there a better or different way that I can RELIABLY achieve what I am trying to do? All help would be greatly appreciated. Regards Andrew

    Read the article

  • How can i solve "An explicit value for the identity column in table"?

    - by Phsika
    if i try to add some data into my table error occurs: Error:Msg 8101, Level 16, State 1, Line 1 An explicit value for the identity column in table 'ENG_PREP' can only be specified when a column list is used and IDENTITY_INSERT is ON. insert into ENG_PREP VALUES('572012-01-1,572012-01-2,572012-01-3,572013-01-1,572013-01-2', '', '500', '', 'A320 P.001-A', 'Removal of the LH Wing Safety Rope', '', '', '', '0', '', 'AF', '12-00-00-081-001', '', '', '', '', '', '', '' )

    Read the article

  • make select @@IDENTITY; a long?

    - by acidzombie24
    I am grabbing the last rowid and i am doing this select @@IDENTITY pk = (long)cmd.ExecuteScalar(); I get an invalid typecast bc this is int instead of long. Why doesnt this return a long? can i make it return long? Solution for now is to use pk = Convert.ToInt64(cmd.ExecuteScalar());

    Read the article

< Previous Page | 790 791 792 793 794 795 796 797 798 799 800 801  | Next Page >