Search Results

Search found 19009 results on 761 pages for 'network shares'.

Page 8/761 | < Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >

  • Windows Explorer slow response when disconnect from the network

    - by ITGuy24
    As a Systems Admin I have seen this issue repeatedly and it drives me crazy. Basically the problem occurs when you open My Documents or My Computer (Windows Explorer) there is a big delay ranging from 5-25 seconds before it actually opens and shows the content. Sometimes the problem continues with each subfolder you open. The problem is most common when disconnected from the network and when you have mapped drives. The most common solution for this problem is to disconnect any mapped drives or printers that are discconected/not reaachable. I have also heard that turning off "Automatically search for network folders and printers" can solve this issue but I have yet to see this work. Does anyone know of any other work arounds for this?

    Read the article

  • Cannot find network path for computer in workgroup of home Windows XP PCs

    - by John Galt
    VMWare Workstation 6.5 is running as an app on a Windows Vista 64bit PC host. Thanks to Workstation we have 2 guest machines running: TerriVM and MattVM (both of these run Windows XP SP2). We are attempting to get virtual networking configured so we can access the files of both of these VM guest systems from other real PCs connected to this home network. We think we are close but we can't quite get it right... Here is what we've done so far: * On VM Workstation, we set "Host Virtual Network Mapping" to use VMnet0 with the setting "Bridge to an automatically chosen adapter". * On each VM guest (i.e. using Windows explorer on XP), we rightmouse on the C disk, click "Sharing" tab, set shareName to "C_Disk" and check both boxes labeled "Share this folder on the network" and "Allow network users to change my files". Symptoms: On "JohnsRealXP" PC, we go to Windows Explorer, My Computer, Map Network Drive, type into Folder textbox: \TerriVM\C_Disk and assign drive letter T. We see all the folders on this shared drive and can open files on them. So that is good. On same "JohnsRealXP" PC, we go to Windows Explorer, My Computer, Map Network Drive, type into Folder textbox: \MattVM\C_Disk and assign drive letter M. We get a message box "_The network path \mattvm\C_Disk could not be found_". Alternatively, we type just \mattvm\ into the Folder box and click "Browse" and get a dialog box where we drill down from "Entire Network" to "Microsoft Windows Network" to "Workgroup" where both TerriVM and MattVM are listed as computers on the network. Clicking the + sign next to MattVM gives an hourglass and never enables the OK button and I have to cancel. In summary, I think we've attempted to share both of these virtual machines using the same techniques and connect to them in similar fashion, but one connects properly and the other machine can be seen but no shared resources on it can be accessed. Can anyone suggest something possibly overlooked or something to try? Thanks so much in advance.

    Read the article

  • Un-balanced network speed although using fiberoptic cable line

    - by Hoàng Long
    I'm not sure this is a right place to ask this question, but there's a strange thing that I don't quite sure what the reason is. My company has hired a fiberoptic cable line for network use (Wifi and cable through a router). But the strange thing is that, whenever someone view YouTube or listen stream music, then network speed for all the others become extremely slow. The download speed for that person is about 4-5 MB/s (or more), but others suffer. I'm still a newbie about networking. But I know there should be a solution. Could anyone tell me a way to stop this bad behavior? It's not possible for asking people not viewing YouTube, since that's part of their jobs. Any insights about this problem would be very welcome.

    Read the article

  • Cannot access shares via \\servername but \\ip works

    - by Jeff
    To set up the scenario: One of our techs set one of the domain controllers to use Microsoft time. The time IS correct (including Time Zone) and DOES match the other domain controller's time; it was previously incorrect, however. Since the change, no users can connect via \\servername\share or \\servername.domainname.com but \\ip\share works fine. I cannot even access it from the other domain controller with which I know both have the same time. The servername DOES resolve to the correct IP address. Also, strangely enough, \\domainname.com works as well which resolves to the same server. Finally Everything that I have tried does resolve to the same, correct IP address. The error is: login failure: The target account name is incorrect. I believe it is time related but since the times are correct and match I'm not sure. Anyone know what might cause this?

    Read the article

  • Why doesn't the network drive not automatically connect?

    - by Sheldon
    I've set up samba on my Ubuntu desktop. It appears to be something to do with the server. With all user accounts on Ubuntu(except the default one I use all the time) windows isn't able to/doesn't automatically map the network drive. In other words: I am only able to to automatically map the network drive on windows with only one of the accounts created on Ubuntu. Edit: I am able to connect using other accounts, I'm just not able to automatically map using those credentials. Details: Windows 7, Ubuntu 12.10

    Read the article

  • Windows 7 Mapped Network Drive Multiplying to Create Duplicates all the way to Z:

    - by bendiy
    A strange issue came in today from some users. At least two Windows 7 x64 boxes that have duplicate mappings of a network drive. The drive is not mapped with a log in script, but done manual through "Map Network Drive". Everything has been fine for months, but all of the sudden, Explorer looks like this: Files (\\fileServerPath) (S:) Files (\\fileServerPath) (T:) Files (\\fileServerPath) (U:) Files (\\fileServerPath) (V:) Files (\\otherServerPath) (W:) Files (\\fileServerPath) (X:) Files (\\fileServerPath) (Y:) Files (\\fileServerPath) (Z:) There are some other networks drives mixed in there that did not duplicate. The drive is normally mapped to S:\, but it decided to make its way to Z:. What is going on here? I've found this and will be trying soon: http://social.technet.microsoft.com/Forums/en/w7itpronetworking/thread/b5647cc3-15d0-4776-bb00-a869bd8f930b

    Read the article

  • Mount Ubuntu shares remotely with Mac and Windows

    - by Donald
    First time on here so please be gentle! I have setup a small school network with a Ubuntu 12.04 Server for use as a fileserver mainly. I have managed to set the server up (all command line based - no GUI) and setup the Samba shares, which works really well internally. Internally, the school have a combination of Mac's and Windows machines and they can all access the shares happily. The school has a fixed IP ADSL connection and I have added a route in the router to allow me remote access to the server using SSH (port 22). That also works well. All good so far! What I now want to do is allow remote access to the shares. I have done a bit of reading and thought I had found the answer with SSHFS but I am still non-the-wiser. So, my basic questions is: In Windows, how can I map to the Ubuntu shares across the internet through the router? In Mac OS, how can I add the remote share across the internet? The school used to have a Windows server and the users were used to creating a VPN and then pulling up the share folders etc, but I'm unsure how to do this with the Ubuntu server. I assume I need to add another route through the router too allow for SSHFS or something similar? Thanks in advance... Donald

    Read the article

  • problem with network-manager-pptp

    - by Riuzaki90
    I've a problema with the VPA CAble connection of my university... on the website of the university there's a .sh file that set all the variables of the connection in ETC/PPP/PEERS and another .sh file that call the connection...I'm on ubuntu 11.10 and when I run the setup.sh I have this error: impossible to find network-manager-pptp these are the two file that I had talk about: #!/bin/bash echo "Creazione della connessione in corso attendere........." apt-get update apt-get install pptp-linux network-manager-pptp echo -n "Digitare la propria Username: " read USERNAME echo -n "Digitare la propria Password: " read PASSWORD pptpsetup --create UNICAL_Campus_Access --server 160.97.73.253 --username $USERNAME --password $PASSWORD echo 'pty "pptp 160.97.73.253 --nolaunchpppd"' >/etc/ppp/peers/UNICAL_Campus_Access echo 'require-mppe-128' >>/etc/ppp/peers/UNICAL_Campus_Access echo 'file /etc/ppp/options.pptp'>>/etc/ppp/peers/UNICAL_Campus_Access echo 'name '$USERNAME''>>/etc/ppp/peers/UNICAL_Campus_Access echo 'remotename PPTP'>>/etc/ppp/peers/UNICAL_Campus_Access echo 'ipparam UNICAL_Campus_Access'>>/etc/ppp/peers/UNICAL_Campus_Access echo $USERNAME' PPTP '$PASSWORD' *'>>/etc/ppp/chap-secrets rm /etc/ppp/options.pptp echo '###############################################################################'>/etc/ppp/options.pptp echo '# $Id: options.pptp,v 1.3 2006/03/26 23:11:05 quozl Exp $'>>/etc/ppp/options.pptp echo '#'>>/etc/ppp/options.pptp echo '# Sample PPTP PPP options file /etc/ppp/options.pptp'>>/etc/ppp/options.pptp echo '# Options used by PPP when a connection is made by a PPTP client.'>>/etc/ppp/options.pptp echo '# This file can be referred to by an /etc/ppp/peers file for the tunnel.'>>/etc/ppp/options.pptp echo '# Changes are effective on the next connection. See "man pppd".'>>/etc/ppp/options.pptp echo '#'>>/etc/ppp/options.pptp echo '# You are expected to change this file to suit your system. As'>>/etc/ppp/options.pptp echo '# packaged, it requires PPP 2.4.2 or later from http://ppp.samba.org/'>>/etc/ppp/options.pptp echo '# and the kernel MPPE module available from the CVS repository also on'>>/etc/ppp/options.pptp echo '# http://ppp.samba.org/, which is packaged for DKMS as kernel_ppp_mppe.'>>/etc/ppp/options.pptp echo '###############################################################################'>>/etc/ppp/options.pptp echo '# Lock the port'>>/etc/ppp/options.pptp echo 'lock'>>/etc/ppp/options.pptp echo '# Authentication'>>/etc/ppp/options.pptp echo '# We do not need the tunnel server to authenticate itself'>>/etc/ppp/options.pptp echo 'noauth'>>/etc/ppp/options.pptp echo '#We won"t do PAP, EAP, CHAP, or MSCHAP, but we will accept MSCHAP-V2'>>/etc/ppp/options.pptp echo '#(you may need to remove these refusals if the server is not using MPPE)'>>/etc/ppp/options.pptp echo 'refuse-pap'>>/etc/ppp/options.pptp echo 'refuse-eap'>>/etc/ppp/options.pptp echo 'refuse-chap'>>/etc/ppp/options.pptp echo 'refuse-mschap'>>/etc/ppp/options.pptp echo '# Compression Turn off compression protocols we know won"t be used'>>/etc/ppp/options.pptp echo 'nobsdcomp'>>/etc/ppp/options.pptp echo 'nodeflate'>>/etc/ppp/options.pptp echo '# Encryption'>>/etc/ppp/options.pptp echo '# (There have been multiple versions of PPP with encryption support,'>>/etc/ppp/options.pptp echo '# choose with of the following sections you will use. Note that MPPE'>>/etc/ppp/options.pptp echo '# requires the use of MSCHAP-V2 during authentication)'>>/etc/ppp/options.pptp echo '# http://ppp.samba.org/ the PPP project version of PPP by Paul Mackarras'>>/etc/ppp/options.pptp echo '# ppp-2.4.2 or later with MPPE only, kernel module ppp_mppe.o'>>/etc/ppp/options.pptp echo '#{{{'>>/etc/ppp/options.pptp echo '# Require MPPE 128-bit encryption'>>/etc/ppp/options.pptp echo '#require-mppe-128'>>/etc/ppp/options.pptp echo '#}}}'>>/etc/ppp/options.pptp echo '# http://polbox.com/h/hs001/ fork from PPP project by Jan Dubiec'>>/etc/ppp/options.pptp echo '#ppp-2.4.2 or later with MPPE and MPPC, kernel module ppp_mppe_mppc.o'>>/etc/ppp/options.pptp echo '#{{{'>>/etc/ppp/options.pptp echo '# Require MPPE 128-bit encryption'>>/etc/ppp/options.pptp echo '#mppe required,stateless'>>/etc/ppp/options.pptp echo '# }}}'>>/etc/ppp/options.pptp echo "setup di 'UNICAL Campus Access' terminato correttamente" echo "per connettersi eseguire lo script 'UNICAL_Campus_Access.sh' " and the second: #!/bin/bash echo "Connessione alla Rete del Centro Residenziale in corso attendere........." modprobe ppp_mppe pppd call UNICAL_Campus_Access sleep 30 tail -n 8 /var/log/messages echo "Connessione Stabilita" echo -n "Per terminare la connessione premere invio (in alternativa eseguire il commando 'killall pppd'):----> " read CONN killall pppd echo "Connessione terminata" I've correctly installed network-manager-pptp to the latest version...help?

    Read the article

  • The Differences between MAC Address and Network Layer Address

    A Mac address is a fixed number associated with a NICs onboard memory. It is initially assigned at the factory. The MAC address is broken up into 2 parts. The first part is the Block id which is six digit sequences that is unique to each vender. The second section is the device id which is created and assigned by the manufacture. A Network layer address is different because there format based on the type of protocol and network used. Also, there unique id is based on a hierarchal addressing theme on subsets of data  and narrowing it down. Just like in an address you can narrow down your house, for example: Florida, Boca Raton, 33428, SW 53th street states that you live in Florida. You also live in the area located in Florida called Boca Raton and you are also in the area of 33428 which is located in Boca Raton. Finally you live on SW 8th street which is in the area of 33428 which is located in Boca Raton which is also located in Florida.

    Read the article

  • Differentiate VMware network adapter from physical network adapters

    - by Venkat
    I have to differentiate between the real addresses and the VM addresses using any Windows API. I'm using Getadaptersaddresses API to populate a list of ipaddresses for the local machine. I need to extract only the "real" addresses apart from the addresses associated with the VMware network adapter and other addresses(auto-configuration and tunnel adapter addresses) I've not been able to find any API or any flag to differentiate this. Is there any way this can be done? PS:The IfType flag in the IP_ADAPTER_ADDRESSES structure returned by Getadaptersaddresses doesn't help me differentiate between VMware addresses and the real addresses

    Read the article

  • Network Logon Issues with Group Policy and Network

    - by bobloki
    I am gravely in need of your help and assistance. We have a problem with our logon and startup to our Windows 7 Enterprise system. We have more than 3000 Windows Desktops situated in roughly 20+ buildings around campus. Almost every computer on campus has the problem that I will be describing. I have spent over one month peering over etl files from Windows Performance Analyzer (A great product) and hundreds of thousands of event logs. I come to you today humbled that I could not figure this out. The problem as simply put our logon times are extremely long. An average first time logon is roughly 2-10 minutes depending on the software installed. All computers are Windows 7, the oldest computers being 5 years old. Startup times on various computers range from good (1-2 minutes) to very bad (5-60). Our second time logons range from 30 seconds to 4 minutes. We have a gigabit connection between each computer on the network. We have 5 domain controllers which also double as our DNS servers. Initial testing led us to believe that this was a software problem. So I spent a few days testing machines only to find inconsistent results from the etl files from xperfview. Each subset of computers on campus had a different subset of software issues, none seeming to interfere with logon just startup. So I started looking at our group policy and located some very interesting event ID’s. Group Policy 1129: The processing of Group Policy failed because of lack of network connectivity to a domain controller. Group Policy 1055: The processing of Group Policy failed. Windows could not resolve the computer name. This could be caused by one of more of the following: a) Name Resolution failure on the current domain controller. b) Active Directory Replication Latency (an account created on another domain controller has not replicated to the current domain controller). NETLOGON 5719 : This computer was not able to set up a secure session with a domain controller in domain OURDOMAIN due to the following: There are currently no logon servers available to service the logon request. This may lead to authentication problems. Make sure that this computer is connected to the network. If the problem persists, please contact your domain administrator. E1kexpress 27: Intel®82567LM-3 Gigabit Network Connection – Network link is disconnected. NetBT 4300 – The driver could not be created. WMI 10 - Event filter with query "SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA "Win32_Processor" AND TargetInstance.LoadPercentage 99" could not be reactivated in namespace "//./root/CIMV2" because of error 0x80041003. Events cannot be delivered through this filter until the problem is corrected. More or less with timestamps it becomes apparent that the network maybe the issue. 1:25:57 - Group Policy is trying to discover the domain controller information 1:25:57 - The network link has been disconnected 1:25:58 - The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator. 1:25:58 - Making LDAP calls to connect and bind to active directory. DC1.ourdomain.edu 1:25:58 - Call failed after 0 milliseconds. 1:25:58 - Forcing rediscovery of domain controller details. 1:25:58 - Group policy failed to discover the domain controller in 1030 milliseconds 1:25:58 - Periodic policy processing failed for computer OURDOMAIN\%name%$ in 1 seconds. 1:25:59 - A network link has been established at 1Gbps at full duplex 1:26:00 - The network link has been disconnected 1:26:02 - NtpClient was unable to set a domain peer to use as a time source because of discovery error. NtpClient will try again in 3473457 minutes and DOUBLE THE REATTEMPT INTERVAL thereafter. 1:26:05 - A network link has been established at 1Gbps at full duplex 1:26:08 - Name resolution for the name %Name% timed out after none of the configured DNS servers responded. 1:26:10 – The TCP/IP NetBIOS Helper service entered the running state. 1:26:11 - The time provider NtpClient is currently receiving valid time data at dc4.ourdomain.edu 1:26:14 – User Logon Notification for Customer Experience Improvement Program 1:26:15 - Group Policy received the notification Logon from Winlogon for session 1. 1:26:15 - Making LDAP calls to connect and bind to Active Directory. dc4.ourdomain.edu 1:26:18 - The LDAP call to connect and bind to Active Directory completed. dc4. ourdomain.edu. The call completed in 2309 milliseconds. 1:26:18 - Group Policy successfully discovered the Domain Controller in 2918 milliseconds. 1:26:18 - Computer details: Computer role : 2 Network name : (Blank) 1:26:18 - The LDAP call to connect and bind to Active Directory completed. dc4.ourdomain.edu. The call completed in 2309 milliseconds. 1:26:18 - Group Policy successfully discovered the Domain Controller in 2918 milliseconds. 1:26:19 - The WinHTTP Web Proxy Auto-Discovery Service service entered the running state. 1:26:46 - The Network Connections service entered the running state. 1:27:10 – Retrieved account information 1:27:10 – The system call to get account information completed. 1:27:10 - Starting policy processing due to network state change for computer OURDOMAIN\%name%$ 1:27:10 – Network state change detected 1:27:10 - Making system call to get account information. 1:27:11 - Making LDAP calls to connect and bind to Active Directory. dc4.ourdomain.edu 1:27:13 - Computer details: Computer role : 2 Network name : ourdomain.edu (Now not blank) 1:27:13 - Group Policy successfully discovered the Domain Controller in 2886 milliseconds. 1:27:13 - The LDAP call to connect and bind to Active Directory completed. dc4.ourdomain.edu The call completed in 2371 milliseconds. 1:27:15 - Estimated network bandwidth on one of the connections: 0 kbps. 1:27:15 - Estimated network bandwidth on one of the connections: 8545 kbps. 1:27:15 - A fast link was detected. The Estimated bandwidth is 8545 kbps. The slow link threshold is 500 kbps. 1:27:17 – Powershell - Engine state is changed from Available to Stopped. 1:27:20 - Completed Group Policy Local Users and Groups Extension Processing in 4539 milliseconds. 1:27:25 - Completed Group Policy Scheduled Tasks Extension Processing in 5210 milliseconds. 1:27:27 - Completed Group Policy Registry Extension Processing in 1529 milliseconds. 1:27:27 - Completed policy processing due to network state change for computer OURDOMAIN\%name%$ in 16 seconds. 1:27:27 – The Group Policy settings for the computer were processed successfully. There were no changes detected since the last successful processing of Group Policy. Any help would be appreciated. Please ask for any relevant information and it will be provided as soon as possible.

    Read the article

  • Finding most efficient transmission size in varying network latency scenarios

    - by rwmnau
    I'm building a .NET remoting client/server that will be transmitting thousands of files, of varying sizes (everything from a few bytes to hundreds of MB), and I'm curious about a general method for finding the appropriate transmission size. As I see it, there's the following tradeoff: Serialize entire file into a transmission object and transmit at once, regardless of size. This would be the fastest, but a failure during tranmission requires that the whole file be re-transmitted. If the file size is larger than something small (like 4KB), break it into 4KB chunks and transmit those, re-assembling on the server. In addition to the complexity of this, it's slower because of continued round-trips and acknowledgements, though a failure of any one piece doesn't waste much time. The ideal transmission method (when taking into account negotiation latency vs. failure rate) is somewhere in between, and I'm wondering about how to find out the best size for that particular client. Do I have some dynamic tuning step in my transmission that looks at the current bytes/second average, and then raises the transmission size until the speed starts to drop (failures overwhelm negotiation cost)? Or is there some other method for determining ideal transmission size? The application will be multi-threaded, so number of threads also factors in to the calculation. I'm not looking for a formula (though I'll take one if you've got it), but just what to consider as I create this process.

    Read the article

  • Network Logon Issues with Group Policy and Network

    - by bobloki
    I am gravely in need of your help and assistance. We have a problem with our logon and startup to our Windows 7 Enterprise system. We have more than 3000 Windows Desktops situated in roughly 20+ buildings around campus. Almost every computer on campus has the problem that I will be describing. I have spent over one month peering over etl files from Windows Performance Analyzer (A great product) and hundreds of thousands of event logs. I come to you today humbled that I could not figure this out. The problem as simply put our logon times are extremely long. An average first time logon is roughly 2-10 minutes depending on the software installed. All computers are Windows 7, the oldest computers being 5 years old. Startup times on various computers range from good (1-2 minutes) to very bad (5-60). Our second time logons range from 30 seconds to 4 minutes. We have a gigabit connection between each computer on the network. We have 5 domain controllers which also double as our DNS servers. Initial testing led us to believe that this was a software problem. So I spent a few days testing machines only to find inconsistent results from the etl files from xperfview. Each subset of computers on campus had a different subset of software issues, none seeming to interfere with logon just startup. So I started looking at our group policy and located some very interesting event ID’s. Group Policy 1129: The processing of Group Policy failed because of lack of network connectivity to a domain controller. Group Policy 1055: The processing of Group Policy failed. Windows could not resolve the computer name. This could be caused by one of more of the following: a) Name Resolution failure on the current domain controller. b) Active Directory Replication Latency (an account created on another domain controller has not replicated to the current domain controller). NETLOGON 5719 : This computer was not able to set up a secure session with a domain controller in domain OURDOMAIN due to the following: There are currently no logon servers available to service the logon request. This may lead to authentication problems. Make sure that this computer is connected to the network. If the problem persists, please contact your domain administrator. E1kexpress 27: Intel®82567LM-3 Gigabit Network Connection – Network link is disconnected. NetBT 4300 – The driver could not be created. WMI 10 - Event filter with query "SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA "Win32_Processor" AND TargetInstance.LoadPercentage 99" could not be reactivated in namespace "//./root/CIMV2" because of error 0x80041003. Events cannot be delivered through this filter until the problem is corrected. More or less with timestamps it becomes apparent that the network maybe the issue. 1:25:57 - Group Policy is trying to discover the domain controller information 1:25:57 - The network link has been disconnected 1:25:58 - The processing of Group Policy failed because of lack of network connectivity to a domain controller. This may be a transient condition. A success message would be generated once the machine gets connected to the domain controller and Group Policy has successfully processed. If you do not see a success message for several hours, then contact your administrator. 1:25:58 - Making LDAP calls to connect and bind to active directory. DC1.ourdomain.edu 1:25:58 - Call failed after 0 milliseconds. 1:25:58 - Forcing rediscovery of domain controller details. 1:25:58 - Group policy failed to discover the domain controller in 1030 milliseconds 1:25:58 - Periodic policy processing failed for computer OURDOMAIN\%name%$ in 1 seconds. 1:25:59 - A network link has been established at 1Gbps at full duplex 1:26:00 - The network link has been disconnected 1:26:02 - NtpClient was unable to set a domain peer to use as a time source because of discovery error. NtpClient will try again in 3473457 minutes and DOUBLE THE REATTEMPT INTERVAL thereafter. 1:26:05 - A network link has been established at 1Gbps at full duplex 1:26:08 - Name resolution for the name %Name% timed out after none of the configured DNS servers responded. 1:26:10 – The TCP/IP NetBIOS Helper service entered the running state. 1:26:11 - The time provider NtpClient is currently receiving valid time data at dc4.ourdomain.edu 1:26:14 – User Logon Notification for Customer Experience Improvement Program 1:26:15 - Group Policy received the notification Logon from Winlogon for session 1. 1:26:15 - Making LDAP calls to connect and bind to Active Directory. dc4.ourdomain.edu 1:26:18 - The LDAP call to connect and bind to Active Directory completed. dc4. ourdomain.edu. The call completed in 2309 milliseconds. 1:26:18 - Group Policy successfully discovered the Domain Controller in 2918 milliseconds. 1:26:18 - Computer details: Computer role : 2 Network name : (Blank) 1:26:18 - The LDAP call to connect and bind to Active Directory completed. dc4.ourdomain.edu. The call completed in 2309 milliseconds. 1:26:18 - Group Policy successfully discovered the Domain Controller in 2918 milliseconds. 1:26:19 - The WinHTTP Web Proxy Auto-Discovery Service service entered the running state. 1:26:46 - The Network Connections service entered the running state. 1:27:10 – Retrieved account information 1:27:10 – The system call to get account information completed. 1:27:10 - Starting policy processing due to network state change for computer OURDOMAIN\%name%$ 1:27:10 – Network state change detected 1:27:10 - Making system call to get account information. 1:27:11 - Making LDAP calls to connect and bind to Active Directory. dc4.ourdomain.edu 1:27:13 - Computer details: Computer role : 2 Network name : ourdomain.edu (Now not blank) 1:27:13 - Group Policy successfully discovered the Domain Controller in 2886 milliseconds. 1:27:13 - The LDAP call to connect and bind to Active Directory completed. dc4.ourdomain.edu The call completed in 2371 milliseconds. 1:27:15 - Estimated network bandwidth on one of the connections: 0 kbps. 1:27:15 - Estimated network bandwidth on one of the connections: 8545 kbps. 1:27:15 - A fast link was detected. The Estimated bandwidth is 8545 kbps. The slow link threshold is 500 kbps. 1:27:17 – Powershell - Engine state is changed from Available to Stopped. 1:27:20 - Completed Group Policy Local Users and Groups Extension Processing in 4539 milliseconds. 1:27:25 - Completed Group Policy Scheduled Tasks Extension Processing in 5210 milliseconds. 1:27:27 - Completed Group Policy Registry Extension Processing in 1529 milliseconds. 1:27:27 - Completed policy processing due to network state change for computer OURDOMAIN\%name%$ in 16 seconds. 1:27:27 – The Group Policy settings for the computer were processed successfully. There were no changes detected since the last successful processing of Group Policy. Any help would be appreciated. Please ask for any relevant information and it will be provided as soon as possible.

    Read the article

  • Neural Network problems

    - by Betamoo
    I am using an external library for Artificial Neural Networks in my project.. While testing the ANN, It gave me output of all NaN (not a number in C#) The ANN has 8 input , 5 hidden , 5 hidden , 2 output, and all activation layers are of Linear type , and it uses back-propagation, with learning rate 0.65 I used one testcase for training { -2.2, 1.3, 0.4, 0.5, 0.1, 5, 3, -5 } ,{ -0.3, 0.2 } for 1000 epoch And I tested it on { 0.2, -0.2, 5.3, 0.4, 0.5, 0, 35, 0.0 } which gave { NaN , NaN} Note: this is one example of many that produces same case... I am trying to discover whether it is a bug in the library, or an illogical configuration.. The reasons I could think of for illogical configuration: All layers should not be linear Can not have descending size layers, i.e 8-5-5-2 is bad.. Only one testcase ? Values must be in range [0,1] or [-1,1] Is any of the above reasons could be the cause of error, or there are some constraints/rules that I do not know in ANN designing..? Note: I am newbie in ANN

    Read the article

  • Ruby: writing a network redirector

    - by Shyam
    Hi, I would like to research protocols such as HTTP. As I am learning Ruby, I would like to write a program that works as a "gateway". I would be connecting to it's port on for example 8080 and the program should forward my request to the real host and send back the answers. The idea of my design is something like this: class EchoProxy def run # run a listening socket on port 8080 myinfiniteloop end def myinfiniteloop # continually run this loop unless the app is terminated puts traffic end end Some pointers in the right direction would be great! Thank you for your comments, answers and feedback!

    Read the article

  • 12.10 cifs shares not mounting after modifying /etc/fstab

    - by Doug
    From Ubuntu 11.04 to 12.04 i've been able to mount my nas shares by first making directories in the /media folder, then : sudo gedit /etc/fstab to include the following line for each share I want to auto-mount; //servername/sharename /media/windowsshare cifs guest,uid=1000,iocharset=utf8,codepage=unicode,unicode 0 0 Now, however, I upgraded to 12.10, and suddenly I'm not able to mount the shares after saving /etc/fstab and sudo mount -a, giving me this error: Refer to the mount.cifs(8) manual page (e.g. man mount.cifs) mount error(22): Invalid argument When in Nautilus, The shares are visible under the network tab, unmounted, and when I click on a share, I get the following message: mount: only root can mount //192.168.1.71/photos on /media/photos I checked to ensure smbfs was installed, and no problems there. I'm stumped.

    Read the article

  • Can't get bonding and bridging to work for KVM

    - by user9546
    Hi everyone. I can't for the life of me get bonding and bridging to work for the KVM setup I'm building. I'm using a fresh install (not an upgrade) of Ubuntu Server 10.10. I have 4 NICs on the same subnet (two intended for each of my two VMs). I'm trying to achieve the setup that Uthark describes here. But following his guidelines didn't work for me. My eth0 and eth1 did not come up, and "brctl show" showed that br0 didn't have any interfaces (the bond). I assumed it didn't work because he's using 10.4, and this article says there's a recent change in bonding: [I can't post more than one hyperlink per post because I'm a newbie.] I had to use this article to get my interfaces to work at all on the same subnet, which is why I have the post-up lines on some of my interfaces: [I can't post more than one hyperlink per post because I'm a newbie.] I installed ifenslave and ethtool. I also created /etc/modprobe.d/aliases.conf with the following content: alias bond0 bonding options bonding mode=6 miimon=100 downdelay=200 updelay=200 And I included "bonding" in /etc/modules So, after several approaches, here is my latest interfaces file: auto lo iface lo inet loopback auto eth5 iface eth5 inet manual auto br5 iface br5 inet static post-up /sbin/ip rule add from [network].79 lookup 10 post-up /sbin/ip route add table 10 default via [network].1 src [network].79 dev br5 address [network].79 netmask 255.255.255.0 network [network].0 broadcast [network].255 gateway [network].1 bridge_ports eth5 bridge_stp off bridge_fd 0 bridge_maxwait 0 auto eth2 iface eth2 inet manual auto br2 iface br2 inet static post-up /sbin/ip rule add from [network].78 lookup 11 post-up /sbin/ip route add table 11 default via [network].1 src [network].78 dev br2 address [network].78 netmask 255.255.255.0 network [network].0 broadcast [network].255 gateway [network].1 bridge_ports eth2 bridge_stp off bridge_fd 0 bridge_maxwait 0 iface eth0 inet manual iface eth1 inet manual auto bond0 iface bond0 inet static bond_miimon 100 bond_mode balance-alb up /sbin/ifenslave bond0 eth0 eth1 down /sbin/ifenslave -d bond0 eth0 eth1 auto br0 iface br0 inet static address [network].60 netmask 255.255.255.0 network [network].0 broadcast [network].255 gateway [network].1 bridge_ports bond0 eth2, eth5, br2, and br5 all seem to be working fine. The only other thing I could find that looked suspicious is an error regarding bonding in /var/log/messages: kernel: [ 3.828684] bonding: Warning: either miimon or arp_interval and arp_ip_target module parameters must be specified, otherwise bonding will not detect link failures! see bonding.txt for details. even though there is a bond-miimon line in /etc/network/interfaces (if that's what they're talking about). Also, the bond seems to go in and out of promiscuous mode several times on boot: Jan 20 14:19:02 kvmhost kernel: [ 3.902378] device bond0 entered promiscuous mode Jan 20 14:19:02 kvmhost kernel: [ 3.902390] device bond0 left promiscuous mode Jan 20 14:19:02 kvmhost kernel: [ 3.902393] device bond0 entered promiscuous mode Jan 20 14:19:02 kvmhost kernel: [ 3.902397] device bond0 left promiscuous mode Jan 20 14:19:03 kvmhost kernel: [ 4.998990] device bond0 entered promiscuous mode Jan 20 14:19:03 kvmhost kernel: [ 4.999005] device bond0 left promiscuous mode Jan 20 14:19:03 kvmhost kernel: [ 4.999008] device bond0 entered promiscuous mode Jan 20 14:19:03 kvmhost kernel: [ 4.999012] device bond0 left promiscuous mode Any advice would be greatly appreciated. It seems that this must be possible, based on other posts, but I can't see what I'm doing wrong. Thanks.

    Read the article

  • cannot connect with huawei e173 after upgrade to 12.10 using network manager

    - by user104195
    Since upgrade from 12.04 to 12.10 I can't connect to internet using mobile broadband modem Huawei e173. It worked earlier without problems and now it seems to be properly recognized (at least its connections appear in network manager applet), and after selecting connection manually it starts connection procedure. After about 20 seconds it returns to state disconnected. After browsing internet I've found that running network manager with: NM_PPP_DEBUG=1 /usr/sbin/NetworkManager --no-daemon After inserting modem I get: NetworkManager[507]: <warn> (ttyUSB2): failed to look up interface index NetworkManager[507]: <info> (ttyUSB2): new GSM/UMTS device (driver: 'option1' ifindex: 0) NetworkManager[507]: <info> (ttyUSB2): exported as /org/freedesktop/NetworkManager/Devices/2 NetworkManager[507]: <info> (ttyUSB2): now managed NetworkManager[507]: <info> (ttyUSB2): device state change: unmanaged -> unavailable (reason 'managed') [10 20 2] NetworkManager[507]: <info> (ttyUSB2): deactivating device (reason 'managed') [2] NetworkManager[507]: <info> (ttyUSB2): device state change: unavailable -> disconnected (reason 'none') [20 30 0] where 'failed to look up interface index' seems to be suspicious. After starting connecting: NetworkManager[507]: <info> Activation (ttyUSB2) starting connection 'Plus - Dostep standardowy' NetworkManager[507]: <info> (ttyUSB2): device state change: disconnected -> prepare (reason 'none') [30 40 0] NetworkManager[507]: <info> Activation (ttyUSB2) Stage 1 of 5 (Device Prepare) scheduled... NetworkManager[507]: <info> Activation (ttyUSB2) Stage 1 of 5 (Device Prepare) started... NetworkManager[507]: <info> (ttyUSB2): device state change: prepare -> need-auth (reason 'none') [40 60 0] NetworkManager[507]: <info> Activation (ttyUSB2) Stage 1 of 5 (Device Prepare) complete. NetworkManager[507]: <info> Activation (ttyUSB2) Stage 1 of 5 (Device Prepare) scheduled... NetworkManager[507]: <info> Activation (ttyUSB2) Stage 1 of 5 (Device Prepare) started... NetworkManager[507]: <info> (ttyUSB2): device state change: need-auth -> prepare (reason 'none') [60 40 0] NetworkManager[507]: <info> Activation (ttyUSB2) Stage 1 of 5 (Device Prepare) complete. NetworkManager[507]: <info> WWAN now enabled by management service NetworkManager[507]: <info> Activation (ttyUSB2) Stage 2 of 5 (Device Configure) scheduled... NetworkManager[507]: <info> Activation (ttyUSB2) Stage 2 of 5 (Device Configure) starting... NetworkManager[507]: <info> (ttyUSB2): device state change: prepare -> config (reason 'none') [40 50 0] NetworkManager[507]: <info> Activation (ttyUSB2) Stage 2 of 5 (Device Configure) successful. NetworkManager[507]: <info> Activation (ttyUSB2) Stage 3 of 5 (IP Configure Start) scheduled. NetworkManager[507]: <info> Activation (ttyUSB2) Stage 2 of 5 (Device Configure) complete. NetworkManager[507]: <info> Activation (ttyUSB2) Stage 3 of 5 (IP Configure Start) started... NetworkManager[507]: <info> (ttyUSB2): device state change: config -> ip-config (reason 'none') [50 70 0] NetworkManager[507]: <info> starting PPP connection NetworkManager[507]: <info> pppd started with pid 663 NetworkManager[507]: <info> Activation (ttyUSB2) Stage 4 of 5 (IPv6 Configure Timeout) scheduled... NetworkManager[507]: <info> Activation (ttyUSB2) Stage 3 of 5 (IP Configure Start) complete. NetworkManager[507]: <info> Activation (ttyUSB2) Stage 4 of 5 (IPv6 Configure Timeout) started... NetworkManager[507]: <info> Activation (ttyUSB2) Stage 4 of 5 (IPv6 Configure Timeout) complete. Plugin /usr/lib/pppd/2.4.5/nm-pppd-plugin.so loaded. ** Message: nm-ppp-plugin: (plugin_init): initializing ** Message: nm-ppp-plugin: (nm_phasechange): status 3 / phase 'serial connection' Removed stale lock on ttyUSB2 (pid 32146) using channel 23 NetworkManager[507]: SCPlugin-Ifupdown: devices added (path: /sys/devices/virtual/net/ppp0, iface: ppp0) NetworkManager[507]: SCPlugin-Ifupdown: device added (path: /sys/devices/virtual/net/ppp0, iface: ppp0): no ifupdown configuration found. NetworkManager[507]: <warn> /sys/devices/virtual/net/ppp0: couldn't determine device driver; ignoring... Using interface ppp0 Connect: ppp0 <--> /dev/ttyUSB2 ** Message: nm-ppp-plugin: (nm_phasechange): status 5 / phase 'establish' sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] NetworkManager[507]: <warn> pppd timed out or didn't initialize our dbus module NetworkManager[507]: <info> Activation (ttyUSB2) Stage 4 of 5 (IPv4 Configure Timeout) scheduled... NetworkManager[507]: <info> Activation (ttyUSB2) Stage 4 of 5 (IPv4 Configure Timeout) started... NetworkManager[507]: <info> (ttyUSB2): device state change: ip-config -> failed (reason 'ip-config-unavailable') [70 120 5] NetworkManager[507]: <warn> Activation (ttyUSB2) failed for connection 'Plus - Dostep standardowy' NetworkManager[507]: <info> Activation (ttyUSB2) Stage 4 of 5 (IPv4 Configure Timeout) complete. NetworkManager[507]: <info> (ttyUSB2): device state change: failed -> disconnected (reason 'none') [120 30 0] NetworkManager[507]: <info> (ttyUSB2): deactivating device (reason 'none') [0] Terminating on signal 15 ** Message: nm-ppp-plugin: (nm_phasechange): status 10 / phase 'terminate' sent [LCP TermReq id=0x2 "User request"] NetworkManager[507]: SCPlugin-Ifupdown: devices removed (path: /sys/devices/virtual/net/ppp0, iface: ppp0) where repeated: sent [LCP ConfReq id=0x1 <asyncmap 0x0> <magic 0x64b4024a> <pcomp> <accomp>] last for about 20 seconds. I've tried to downgrade network manager but failed due to many dependencies. Can anyone point me to solution or tell what should I do to further investigate the problem?

    Read the article

  • KVM Bridged Network Not Working

    - by EApubs
    I just installed KVM on my Ubuntu Server according to this guide : https://help.ubuntu.com/community/KVM/Installation Then prepared a bridged network as shown in here : https://help.ubuntu.com/community/KVM/Networking Then, I created a virtual machine with virt-manager. I tried several times but the guest fails to connect to the network! Any help? ifconfig : br0 Link encap:Ethernet HWaddr d0:27:88:b0:e4:38 inet addr:192.168.20.100 Bcast:192.168.20.255 Mask:255.255.255.0 inet6 addr: fe80::d227:88ff:feb0:e438/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:62 errors:0 dropped:0 overruns:0 frame:0 TX packets:62 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:10493 (10.4 KB) TX bytes:8433 (8.4 KB) eth0 Link encap:Ethernet HWaddr d0:27:88:b0:e4:38 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:62 errors:0 dropped:0 overruns:0 frame:0 TX packets:63 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:11361 (11.3 KB) TX bytes:8479 (8.4 KB) Interrupt:41 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) virbr0 Link encap:Ethernet HWaddr 5a:8c:57:95:af:3b inet addr:192.168.122.1 Bcast:192.168.122.255 Mask:255.255.255.0 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) brctl show : bridge name bridge id STP enabled interfaces br0 8000.d02788b0e438 no eth0 virbr0 8000.000000000000 yes brctl showmacs br0 : port no mac addr is local? ageing timer 1 5c:d9:98:67:b6:28 no 48.33 1 d0:27:88:b0:e4:38 yes 0.00 1 e0:2a:82:f9:6c:09 no 0.00 ip route : default via 192.168.20.1 dev br0 metric 100 192.168.20.0/24 dev br0 proto kernel scope link src 192.168.20.100 192.168.122.0/24 dev virbr0 proto kernel scope link src 192.168.122.1 *In the guest * I was unable to copy paste the info from the guest because can't ssh to it. It didn't get any ip from DHCP. Won't work even after setting it up manually.

    Read the article

  • Network configuration problem with ubuntu

    - by Musti
    I am a new Ubuntu user. In my dorm there is a bit strange connection way for internet, I have to configure given "IP address, Subnetmask, Default gateway, Preferred DNS server, and Alternate DNS server" to have an internet connection, otherwise it is imposible. Actually it is very easy in windows, I am just opening Network and Sharing Center and then setting up TCP/IPv4. I had some attempt in Ubuntu, but just failed :/ Can anyone tell me how to configure? Thanks in advance... Musti

    Read the article

  • How to scan local network (LAN) for connected devices (Mac OS)

    - by smotchkkiss
    I'm basically looking for something like this but available on Mac. I am trying to connect a new workstation to our wireless multifunction printer and I'm having a hell of a time getting the device to spit out an IP for me to connect to. Is there a way I can scan the network somehow? If it makes a difference, the new workstation is using Mac OS X 10.6 Thanks in advance :)

    Read the article

  • How to scan local network (LAN) for connected devices (MacOS)

    - by smotchkkiss
    I'm basically looking for something like this but available on Mac. I am trying to connect a new workstation to our wireless multifunction printer and I'm having a hell of a time getting the device to spit out an IP for me to connect to. Is there a way I can scan the network somehow? If it makes a difference, the new workstation is using MacOS X 10.6 Thanks in advance :)

    Read the article

  • Ops Center 12c - Provisioning Solaris Using a Card-Based NIC

    - by scottdickson
    It's been a long time since last I added something here, but having some conversations this last week, I got inspired to update things. I've been spending a lot of time with Ops Center for managing and installing systems these days.  So, I suspect a number of my upcoming posts will be in that area. Today, I want to look at how to provision Solaris using Ops Center when your network is not connected to one of the built-in NICs.  We'll talk about how this can work for both Solaris 10 and Solaris 11, since they are pretty similar.  In both cases, WANboot is a key piece of the story. Here's what I want to do:  I have a Sun Fire T2000 server with a Quad-GbE nxge card installed.  The only network is connected to port 2 on that card rather than the built-in network interfaces.  I want to install Solaris on it across the network, either Solaris 10 or Solaris 11.  I have met with a lot of customers lately who have a similar architecture.  Usually, they have T4-4 servers with the network connected via 10GbE connections. Add to this mix the fact that I use Ops Center to manage the systems in my lab, so I really would like to add this to Ops Center.  If possible, I would like this to be completely hands free.  I can't quite do that yet. Close, but not quite. WANBoot or Old-Style NetBoot? When a system is installed from the network, it needs some help getting the process rolling.  It has to figure out what its network configuration (IP address, gateway, etc.) ought to be.  It needs to figure out what server is going to help it boot and install, and it needs the instructions for the installation.  There are two different ways to bootstrap an installation of Solaris on SPARC across the network.   The old way uses a broadcast of RARP or more recently DHCP to obtain the IP configuration and the rest of the information needed.  The second is to explicitly configure this information in the OBP and use WANBoot for installation WANBoot has a number of benefits over broadcast-based installation: it is not restricted to a single subnet; it does not require special DHCP configuration or DHCP helpers; it uses standard HTTP and HTTPS protocols which traverse firewalls much more easily than NFS-based package installation.  But, WANBoot is not available on really old hardware and WANBoot requires the use o Flash Archives in Solaris 10.  Still, for many people, this is a great approach. As it turns out, WANBoot is necessary if you plan to install using a NIC on a card rather than a built-in NIC. Identifying Which Network Interface to Use One of the trickiest aspects to this process, and the one that actually requires manual intervention to set up, is identifying how the OBP and Solaris refer to the NIC that we want to use to boot.  The OBP already has device aliases configured for the built-in NICs called net, net0, net1, net2, net3.  The device alias net typically points to net0 so that when you issue the command  "boot net -v install", it uses net0 for the boot.  Our task is to figure out the network instance for the NIC we want to use.  We will need to get to the OBP console of the system we want to install in order to figure out what the network should be called.  I will presume you know how to get to the ok prompt.  Once there, we have to see what networks the OBP sees and identify which one is associated with our NIC using the OBP command show-nets. SunOS Release 5.11 Version 11.0 64-bit Copyright (c) 1983, 2011, Oracle and/or its affiliates. All rights reserved. {4} ok banner Sun Fire T200, No Keyboard Copyright (c) 1998, 2010, Oracle and/or its affiliates. All rights reserved. OpenBoot 4.30.4.b, 32640 MB memory available, Serial #69057548. Ethernet address 0:14:4f:1d:bc:c, Host ID: 841dbc0c. {4} ok show-nets a) /pci@7c0/pci@0/pci@2/network@0,1 b) /pci@7c0/pci@0/pci@2/network@0 c) /pci@780/pci@0/pci@8/network@0,3 d) /pci@780/pci@0/pci@8/network@0,2 e) /pci@780/pci@0/pci@8/network@0,1 f) /pci@780/pci@0/pci@8/network@0 g) /pci@780/pci@0/pci@1/network@0,1 h) /pci@780/pci@0/pci@1/network@0 q) NO SELECTION Enter Selection, q to quit: d /pci@780/pci@0/pci@8/network@0,2 has been selected. Type ^Y ( Control-Y ) to insert it in the command line. e.g. ok nvalias mydev ^Y for creating devalias mydev for /pci@780/pci@0/pci@8/network@0,2 {4} ok devalias ... net3 /pci@7c0/pci@0/pci@2/network@0,1 net2 /pci@7c0/pci@0/pci@2/network@0 net1 /pci@780/pci@0/pci@1/network@0,1 net0 /pci@780/pci@0/pci@1/network@0 net /pci@780/pci@0/pci@1/network@0 ... name aliases By looking at the devalias and the show-nets output, we can see that our Quad-GbE card must be the device nodes starting with  /pci@780/pci@0/pci@8/network@0.  The cable for our network is plugged into the 3rd slot, so the device address for our network must be /pci@780/pci@0/pci@8/network@0,2. With that, we can create a device alias for our network interface.  Naming the device alias may take a little bit of trial and error, especially in Solaris 11 where the device alias seems to matter more with the new virtualized network stack. So far in my testing, since this is the "next" network interface to be used, I have found success in naming it net4, even though it's a NIC in the middle of a card that might, by rights, be called net6 (assuming the 0th interface on the card is the next interface identified by Solaris and this is the 3rd interface on the card).  So, we will call it net4.  We need to assign a device alias to it: {4} ok nvalias net4 /pci@780/pci@0/pci@8/network@0,2 {4} ok devalias net4 /pci@780/pci@0/pci@8/network@0,2 ... We also may need to have the MAC for this particular interface, so let's get it, too.  To do this, we go to the device and interrogate its properties. {4} ok cd /pci@780/pci@0/pci@8/network@0,2 {4} ok .properties assigned-addresses 82060210 00000000 03000000 00000000 01000000 82060218 00000000 00320000 00000000 00008000 82060220 00000000 00328000 00000000 00008000 82060230 00000000 00600000 00000000 00100000 local-mac-address 00 21 28 20 42 92 phy-type mif ... From this, we can see that the MAC for this interface is  00:21:28:20:42:92.  We will need this later. This is all we need to do at the OBP.  Now, we can configure Ops Center to use this interface. Network Boot in Solaris 10 Solaris 10 turns out to be a little simpler than Solaris 11 for this sort of a network boot.  Since WANBoot in Solaris 10 fetches a specified In order to install the system using Ops Center, it is necessary to create a OS Provisioning profile and its corresponding plan.  I am going to presume that you already know how to do this within Ops Center 12c and I will just cover the differences between a regular profile and a profile that can use an alternate interface. Create a OS Provisioning profile for Solaris 10 as usual.  However, when you specify the network resources for the primary network, click on the name of the NIC, probably GB_0, and rename it to GB_N/netN, where N is the instance number you used previously in creating the device alias.  This is where the trial and error may come into play.  You may need to try a few instance numbers before you, the OBP, and Solaris all agree on the instance number.  Mark this as the boot network. For Solaris 10, you ought to be able to then apply the OS Provisioning profile to the server and it should install using that interface.  And if you put your cards in the same slots and plug the networks into the same NICs, this profile is reusable across multiple servers. Why This Works If you watch the console as Solaris boots during the OSP process, Ops Center is going to look for the device alias netN.  Since WANBoot requires a device alias called just net, Ops Center uses the value of your netN device alias and assigns that device to the net alias.  That means that boot net will automatically use this device.  Very cool!  Here's a trace from the console as Ops Center provisions a server: Sun Sun Fire T200, No KeyboardCopyright (c) 1998, 2010, Oracle and/or its affiliates. All rights reserved.OpenBoot 4.30.4.b, 32640 MB memory available, Serial #69057548.Ethernet address 0:14:4f:1d:bc:c, Host ID: 841dbc0c.auto-boot? =            false{0} ok  {0} ok printenv network-boot-argumentsnetwork-boot-arguments =  host-ip=10.140.204.234,router-ip=10.140.204.1,subnet-mask=255.255.254.0,hostname=atl-sewr-52,client-id=0100144F1DBC0C,file=http://10.140.204.22:5555/cgi-bin/wanboot-cgi{0} ok {0} ok devalias net net                      /pci@780/pci@0/pci@1/network@0{0} ok devalias net4 net4                     /pci@780/pci@0/pci@8/network@0,2{0} ok devalias net /pci@780/pci@0/pci@8/network@0,2{0} ok setenv network-boot-arguments host-ip=10.140.204.234,router-ip=10.140.204.1,subnet-mask=255.255.254.0,hostname=atl-sewr-52,client-id=0100144F1DBC0C,file=http://10.140.204.22:8004/cgi-bin/wanboot-cginetwork-boot-arguments =  host-ip=10.140.204.234,router-ip=10.140.204.1,subnet-mask=255.255.254.0,hostname=atl-sewr-52,client-id=0100144F1DBC0C,file=http://10.140.204.22:8004/cgi-bin/wanboot-cgi{0} ok {0} ok boot net - installBoot device: /pci@780/pci@0/pci@8/network@0,2  File and args: - install/pci@780/pci@0/pci@8/network@0,2: 1000 Mbps link up<time unavailable> wanboot info: WAN boot messages->console<time unavailable> wanboot info: configuring /pci@780/pci@0/pci@8/network@0,2 See what happened?  Ops Center looked for the network device alias called net4 that we specified in the profile, took the value from it, and made it the net device alias for the boot.  Pretty cool! WANBoot and Solaris 11 Solaris 11 requires an additional step since the Automated Installer in Solaris 11 uses the MAC address of the network to figure out which manifest to use for system installation.  In order to make sure this is available, we have to take an extra step to associate the MAC of the NIC on the card with the host.  So, in addition to creating the device alias like we did above, we also have to declare to Ops Center that the host has this new MAC. Declaring the NIC Start out by discovering the hardware as usual.  Once you have discovered it, take a look under the Connectivity tab to see what networks it has discovered.  In the case of this system, it shows the 4 built-in networks, but not the networks on the additional cards.  These are not directly visible to the system controller.  In order to add the additional network interface to the hardware asset, it is necessary to Declare it.  We will declare that we have a server with this additional NIC, but we will also  specify the existing GB_0 network so that Ops Center can associate the right resources together.  The GB_0 acts as sort of a key to tie our new declaration to the old system already discovered.  Go to the Assets tab, select All Assets, and then in the Actions tab, select Add Asset.  Rather than going through a discovery this time, we will manually declare a new asset. When we declare it, we will give the hostname, IP address, system model that match those that have already been discovered.  Then, we will declare both GB_0 with its existing MAC and the new GB_4 with its MAC.  Remember that we collected the MAC for GB_4 when we created its device alias. After you declare the asset, you will see the new NIC in the connectivity tab for the asset.  You will notice that only the NICs you listed when you declared it are seen now.  If you want Ops Center to see all of the existing NICs as well as the additional one, declare them as well.  Add the other GB_1, GB_2, GB_3 links and their MACs just as you did GB_0 and GB_4.  Installing the OS  Once you have declared the asset, you can create an OS Provisioning profile for Solaris 11 in the same way that you did for Solaris 10.  The only difference from any other provisioning profile you might have created already is the network to use for installation.  Again, use GB_N/netN where N is the interface number you used for your device alias and in your declaration.  And away you go.  When the system boots from the network, the automated installer (AI) is able to see which system manifest to use, based on the new MAC that was associated, and the system gets installed. {0} ok {0} ok printenv network-boot-argumentsnetwork-boot-arguments =  host-ip=10.140.204.234,router-ip=10.140.204.1,subnet-mask=255.255.254.0,hostname=atl-sewr-52,client-id=01002128204292,file=http://10.140.204.22:5555/cgi-bin/wanboot-cgi{0} ok {0} ok devalias net net                      /pci@780/pci@0/pci@1/network@0{0} ok devalias net4 net4                     /pci@780/pci@0/pci@8/network@0,2{0} ok devalias net /pci@780/pci@0/pci@8/network@0,2{0} ok setenv network-boot-arguments host-ip=10.140.204.234,router-ip=10.140.204.1,subnet-mask=255.255.254.0,hostname=atl-sewr-52,client-id=01002128204292,file=http://10.140.204.22:5555/cgi-bin/wanboot-cginetwork-boot-arguments =  host-ip=10.140.204.234,router-ip=10.140.204.1,subnet-mask=255.255.254.0,hostname=atl-sewr-52,client-id=01002128204292,file=http://10.140.204.22:5555/cgi-bin/wanboot-cgi{0} ok {0} ok boot net - installBoot device: /pci@780/pci@0/pci@8/network@0,2  File and args: - install/pci@780/pci@0/pci@8/network@0,2: 1000 Mbps link up<time unavailable> wanboot info: WAN boot messages->console<time unavailable> wanboot info: configuring /pci@780/pci@0/pci@8/network@0,2...SunOS Release 5.11 Version 11.0 64-bitCopyright (c) 1983, 2011, Oracle and/or its affiliates. All rights reserved.Remounting root read/writeProbing for device nodes ...Preparing network image for useDownloading solaris.zlib--2012-02-17 15:10:17--  http://10.140.204.22:5555/var/js/AI/sparc//solaris.zlibConnecting to 10.140.204.22:5555... connected.HTTP request sent, awaiting response... 200 OKLength: 126752256 (121M) [text/plain]Saving to: `/tmp/solaris.zlib'100%[======================================>] 126,752,256 28.6M/s   in 4.4s    2012-02-17 15:10:21 (27.3 MB/s) - `/tmp/solaris.zlib' saved [126752256/126752256] Conclusion So, why go to all of this trouble?  More and more, I find that customers are wiring their data center to only use higher speed networks - 10GbE only to the hosts.  Some customers are moving aggressively toward consolidated networks combining storage and network on CNA NICs.  All of this means that network-based provisioning cannot rely exclusively on the built-in network interfaces.  So, it's important to be able to provision a system using other than the built-in networks.  Turns out, that this is pretty straight-forward for both Solaris 10 and Solaris 11 and fits into the Ops Center deployment process quite nicely. Hopefully, you will be able to use this as you build out your own private cloud solutions with Ops Center.

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >