Search Results

Search found 1253 results on 51 pages for 'san jacinto'.

Page 8/51 | < Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >

  • Creating basic, redundant gigE or IB storage network for Xen?

    - by StaringSkyward
    With only a modest budget, I want to move my 4 xen servers over to network storage -either NFS or iSCSI which will be determined based on how well it performs when we test it (we need good throughput and it must continue to work through link and switch failure tests). We may add another couple of xen servers at some point when this is done. I don't know much about the design and operation of storage networks, so would really appreciate some hints from those with experience. The budget is around $3,800 excluding the storage appliance. I am currently thinking these are my options to remain on budget: 1) Go for used infiniband hardware and aim for 10gb performance. 2) Stick with gig ethernet and buy some new switches (cisco or procurve) to create a storage-only ethernet LAN. Upgrade to 10gigE later but try to use hardware capable of it where possible to reduce upgrade costs. I have seen used, warrantied infiniband switches at reasonable prices (presumably because big companies are converging on 10gbit ethernet?) and the promise of cheap 10gb is attractive. I know nothing about IB, so here come the questions: Can I buy 2 x switches and have multiple HBAs in my xen and storage nodes to get redundancy and increased performance without complexity or expensive management software costs? If so, can you point me to some examples? Do NFS and iSCSI work just the same regardless? Is IB a sensible choice or could/should I use ethernet or FC on the same budget - I'm keen not to get boxed into a corner for future upgrades, however. For the storage I am likely to build a storage server using nexentastor with the intention that I can later add more disks, SSDs and add another server to provide a failover option at the storage level. An HP LeftHand starter SAN is also under consideration, too. Thanks in advance.

    Read the article

  • vmdk Recovery after migration from 3.5 to 4 and fallback tentative.

    - by olgirard
    Hy, I've tryed to migrate some VM from my 3.5i environment to a brand new vSphere 4.0 U1. The two platforms are running simultaneously, sharing the same SAN. I Migrate my VM by stopping it, unregistering in vcenter (esx ver. 3.5, i call it esx3), register in vSphere (esx ver. 4, i call it esx4), and migrate upgrade virtual hardware before powering it up (First mistake). vMotion was enabled on esx4, seem to be a second mistake. After a day or so, i encountred problems joigning the esx server (esx4) and decided to unregister my server for esx4 and fallback to esx3. esx3 refused to boot, i supposed this was due to virtual hardware in Version 7 so i recreated a new VM pointing to the vmdk of the old VM. Everithing seemed fine until i log into the server and discover that i was running on the original disk ith every snapshots ignored even those created on esx3. I tried to reboot VM on esx4 but VM doesn't power up because "The parent virtual disk has been modified since the child was created". I've got a copy of a later state of the drive but generated between two snapshots (ovf generated with canverter standalone) as a backup. Do i have a chance to recover at least some files on the virtual drive or (as i tink) all is played, i've done enought mistakes for this time. Thanks for your help.

    Read the article

  • VMWare Raw Device Mapping Not Working

    - by George H. Lenzer
    While I'm waiting for VMWare support to get back to me, I thought I'd ask here. I have a 400 gig LUN presented from a fiber channel SAN to my VMWare host. It's legacy from another virtualization platform and I need to keep it as is to avoid a long period of downtime. I formatted my VMFS3 datastore with 4 meg blocks to allow up to 1 TB disks. Then I tried adding my 400 gig disk as a raw device in physical compatibility mode. I get the error: "File is larger than the maximum size supported by datastore 'Base Test'. [Base Test]VMTEST01/VMTEST01_2.vmdk Originally I had the VMFS datastore formatted with 1 meg blocks which was the cause of this problem since the largest disk allowed would be 256 gigs. But I deleted the data store and then reformatted with 4 megs blocks. I've also tried using virtual compatibility mode for the raw device but it still fails. Does anyone have any suggestions? I've been waiting for a little over a week for VMWare, but that's fine because I'm not yet a paying customer. I'm still in the eval phase.

    Read the article

  • What to look for in a switch with LAN/WAN verses an iSCSI SAN?

    - by Luke
    I'm setting up a VMWare ESXi 5 environment with 3 server nodes. Dell recommended 2x Force10 S60 switches shared (iSCSI SAN, LAN/WAN). The S60 switches are extremely powerful. They have 1.25 GB of buffer cache, < 9us latency. But they are very expensive (online price ~$15k per switch, actual quote a little less). I've been told that "by the book" you should at least have 2 internal switches for SAN, and 2 switches for LAN/WAN (each with a redundant). I know some of the pros and cons of each approach. What I'm wondering is, would it be more cost effective to disjoin the SAN from LAN with less expensive switches? The answer to this question highlights what I should be looking for in a switch for the SAN. What should I be looking for in a LAN/WAN switch, in comparison to the SAN? With the above linked question for the SAN: How is buffer latency measured? When you see 36 MB of buffer cache, is that shared or per port? So 36 MB would be 768kb or 36MB per port? With 3 to 6 servers how much buffer cache do you really need? What else should I be looking at? Our application will be heavily using HTML5 websockets (high number of persistent connections). The amount of data being sent is small; Data sent between client <- server isn't broadcasted (not a chat/IM service). We will be doing some database reporting too (csv export, sums, some joins). We are a small business and on a budget. We'd probably only be able to spend no more than $20k on switches total (2 or 4).

    Read the article

  • What is the max supported number of SATA devices (using cable adapters) on a Dell SAS 6/iR adapter?

    - by Zac B
    I've got a Dell SAS 6/iR PCI-E adapter. I don't have a multiplier backplane. I'm planning on connecting SATA (non SAS) drives. If I buy cable adapters only (ones that split a SAS connector on the card to a certain number of SATA cables), how many drives can I connect to this card? The way I see it, there are two limitations: a limitation imposed by the theoretical max number of devices supported on the card (which I've dug through the specs to find, but haven't seen yet), and a limitation imposed by the number of SAS plugs on the card multiplied by the number of SATA cables that come out of the highest-multiplying splitter I can buy. The answer to my question would be the minimum of those two limitations. I've seen 4x SATA coming out of some splitters; are there any that have more? Alternatively, if this is an RTFM question, does anyone have a good link to a "this is how SAS works, this is how you figure out the max number of devices, and this is how the concepts of 'ports', 'lanes', 'endpoint devices', and 'connectors' all relate in SAS-land" document? I've looked around on the Dell docs, but haven't found anything that explains this to someone at my level of understanding of SAN/enterprise storage technologies. Cheers!

    Read the article

  • How to configure multiple iSCSI Portal Groups on a EqualLogic PS6100?

    - by kce
    I am working on a migration from a VMware vSphere environment to a Hyper-V Cluster utilizing Windows Server 2012 R2. The setup is pretty small, an EqualLogic PS6100e and two Dell PowerConnect 5424 switches and handful of R710s and R620s. The SAN was configured as a non-RFC1918 network that is not assigned to our organization and since I am working on building a new virtualization environment I figured that this would be an appropriate time to do a subnet migration. I configured a separate VLAN and subnet on the switches and the two previously unused NICs on the PS6100's controllers. At this time I only have a single Hyper-V host cabled in but I can successfully ping the PS6100 from the host. From the PS6100 I can ping each of the four NICs that currently on the storage network. I cannot connect the Microsoft iSCSI Initiator to the Target. I have successfully added the Target Portals (the IP addresses of PS6100 NICs) and the Targets are discovered but listed as inactive. If I try to Connect to them I get the following error, "Log onto Target - Connection Failed" and ISCSIPrt 1 and 70 events are recorded in the Event Log. I have verified that access control to the volume is not the problem by temporarily disabling it. I suspect the problem is with the Portal Group IP address which is still listed as Group Address of old subnet (I know, I know I might be committing the sin of the X/Y problem but everything else looks good): RFC3720 has this to say about Network Portal and Portal Groups: Network Portal: The Network Portal is a component of a Network Entity that has a TCP/IP network address and that may be used by an iSCSI Node within that Network Entity for the connection(s) within one of its iSCSI sessions. A Network Portal in an initiator is identified by its IP address. A Network Portal in a target is identified by its IP address and its listening TCP port. Portal Groups: iSCSI supports multiple connections within the same session; some implementations will have the ability to combine connections in a session across multiple Network Portals. A Portal Group defines a set of Network Portals within an iSCSI Network Entity that collectively supports the capability of coordinating a session with connections spanning these portals. Not all Network Portals within a Portal Group need participate in every session connected through that Portal Group. One or more Portal Groups may provide access to an iSCSI Node. Each Network Portal, as utilized by a given iSCSI Node, belongs to exactly one portal group within that node. The EqualLogic Group Manager documentation has this to say about the Group IP Address: You use the group IP address as the iSCSI discovery address when connecting initiators to iSCSI targets in the group. If you modify the group IP address, you might need to change your initiator configuration to use the new discovery address Changing the group IP address disconnects any iSCSI connections to the group and any administrators logged in to the group through the group IP address. Which sounds equivalent to me (I am following up with support to confirm). I think a reasonable explanation at this point is that the Initiator can't complete the connection to the Target because the Group IP Address / Network Portal is on a different subnet. I really want to avoid a cutover and would prefer to run both subnets side-by-side until I can install and configure each Hyper-V host. Question/s: Is my assessment at all reasonable? Is it possible to configure multiple Group IP Addresses on the EqualLogic PS6100? I don't want to just change it as it will disconnect the remaining ESXi hosts. Am I just Doing It Wrong(TM)?

    Read the article

  • Android NDK r4 san-angeles problem

    - by Goz
    Hi All, I'm starting to learn the android NDK and I've instantly come up against a problem. I'e built the tool chain (which took a LOT longer than I was expecting!!) and I've compiled the C++ code with no problems and now I'm trying to build the java code. Instantly I come up against a problem. There is a file "main.xml" <?xml version="1.0" encoding="utf-8"?> <LinearLayout xmlns:android="http://schemas.android.com/apk/res/android" android:orientation="vertical" android:layout_width="match_parent" android:layout_height="match_parent" > <TextView android:layout_width="match_parent" android:layout_height="wrap_content" android:text="Hello World, DemoActivity" /> </LinearLayout> and I get the following errors: Description Resource Path Location Type error: Error: String types not allowed (at 'layout_height' with value 'match_parent'). main.xml /DemoActivity/res/layout line 2 Android AAPT Problem error: Error: String types not allowed (at 'layout_height' with value 'match_parent'). main.xml /DemoActivity/res/layout line 2 Android AAPT Problem error: Error: String types not allowed (at 'layout_width' with value 'match_parent'). main.xml /DemoActivity/res/layout line 2 Android AAPT Problem error: Error: String types not allowed (at 'layout_width' with value 'match_parent'). main.xml /DemoActivity/res/layout line 7 Android AAPT Problem error: Error: String types not allowed (at 'layout_width' with value 'match_parent'). main.xml /DemoActivity/res/layout line 7 Android AAPT Problem So I can see the problem lies in the fact that these "match_parent" strings are in there. Anyone know how to fix this?

    Read the article

  • Command View EVA Login Problem

    - by ngadimin
    I'm using Command View EVA version 9.01 on a Windows Storage Server 2003 R2. And all of a sudden I can't log in to the command view, it always say incorrect username or password, I haven't done any change on the password nor the system. Is there any way I can fix this?

    Read the article

  • Replicate / SYNC / Copy thousands of files

    - by rihatum
    Windows 32BIT Box (Server OS) 4GB RAM a 800GB LUN Mapped to the above box as a local drive Around 700GB of text files (Yes text files and a few thousand word documents) nested in thousands of directories. I need to move this to a new storage and map another server to it. What would be the best way to go about it ? What I did was mapped the existing LUN to our new box and mapped a LUN from the New storage to the new box too, and tried copying (windows copy) but that wasn't good / fast enough considering the downtime. I am now looking for either a script which will do this or a utility (prefer opensource / free) to move this size of data at a good speed. 2 x 1GB Nics teamed ether channel 2GBPs Any suggestions or pointers would be off great help Thanks !

    Read the article

  • Windows 2008 Unknown Disks

    - by Ailbe
    I have a BL460c G7 blade server with OS Windows 2008 R2 SP1. This is a brand new C7000 enclosure, with FlexFabric interconnects. I got my FC switches setup and zoned properly to our Clariion CX4, and can see all the hosts that are assigned FCoE HBAs on both paths in both Navisphere and in HP Virtual Connect Manager. So I went ahead and created a storage group for a test server, assigned the appropriate host, assigned the LUN to the server. So far so good, log onto server and I can see 4 unknown disks.... No problem, I install MS MPIO, no luck, can't initialize the disks, and the multiple disks don't go away. Still no problem, I install PowerPath version 5.5 reboot. Now I see 3 disks. One is initialized and ready to go, but I still have 2 disks that I can't initialize, can't offline, can't delete. If I right click in storage manager and go to properties I can see that the MS MPIO tab, but I can't make a path active. I want to get rid of these phantom disks, but so far nothing is working and google searches are showing up some odd results, so obviously I'm not framing my question right. I thought I'd ask here real quick. Does anyone know a quick way to get rid of these unknown disks. Another question, do I need the MPIO feature installed if I have PowerPath installed? This is my first time installing Windows 2008 R2 in this fashion and I'm not sure if that feature is needed or not right now. So some more information to add to this. It seems I'm dealing with more of a Windows issue than anything else. I removed the LUN from the server, uninstalled PowerPath completely, removed the MPIO feature from the server, and rebooted twice. Now I am back to the original 4 Unknown Disks (plus the local Disk 0 containing the OS partition of course, which is working fine) I went to diskpart, I could see all 4 Unknown disks, I selected each disk, ran clean (just in case i'd somehow brought them online previously as GPT and didn't realize it) After a few minutes I was no longer able to see the disks when I ran list disk. However, the disks are still in Disk Management. When I try and offline the disks from Disk Management I get an error: Virtual Disk Manager - The system cannot find the file specified. Accompanied by an error in System Event Logs: Log Name: System Source: Virtual Disk Service Date: 6/25/2012 4:02:01 PM Event ID: 1 Task Category: None Level: Error Keywords: Classic User: N/A Computer: hostname.local Description: Unexpected failure. Error code: 2@02000018 Event Xml: 1 2 0 0x80000000000000 4239 System hostname.local 2@02000018 I feel sure there is a place I can go in the Registry to get rid of these, I just can't recall where and I am loathe to experiement. So to recap, there are currently no LUNS attached at all, I still have the phantom disks, and I'm getting The system cannot find the file specified from Virtual Disk Manager when I try to take them offline. Thanks!

    Read the article

  • update all the servers through one virtual servers using Storage are network virtual machine

    - by Mr.Calm
    Using UBUNTU and Virtal Box by Oracle, and Using this script to start nginx in Virtual Box, and placing it in Virtual box inside~/init.d #!/bin/bash ### BEGIN INIT INFO # Provides: Testinit # Required-Start: # Required-Stop: # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: Start daemon at boot time # Description: Enable service provided by daemon. ### END INIT INFO # RETVAL=0; start() { CurrentTime=$(date +%d/%m/%Y"-"%I:%M:%S) ./usr/local/nginx/sbin/nginx echo "Current Time:"$CurrentTime>>/home/server/Desktop/NginxLogs.txt echo "!Starting nginx!" >>/home/server/Desktop/NginxLogs.txt Like this i want to write auto script (setup.sh file) and place that script in all virtual boxes inside my system, for example 8 virtual boxes and in all Virtual boxes NGINX is installed. Now, The thing is i am facing problem when i want change something in setup.sh i have to go to each and every virtual box, or Communicate each Virtual machine through SSH from my main machine. i am thinking to write another script (ex: Update.sh),and inside that script we give one path of file which is saved and recently edited in main machine (ex: DummySetup.sh). as soon as i run that script all the setup.sh files which are saved in each virtual machines should update the change or replace contents with DummySetup.sh's contents. Hope this is possible thing. Help would be appreciated.Thanking you

    Read the article

  • Snap Server 18000 connection help!

    - by sicko666
    I wonder if anyone here can help me. I have a home server setup made up of old secondhand computers, 2 servers running Windows Server 2003, 1 workstation running Windows 7, a 16 port switch & an adsl ethernet modem. All these connect and talk to each other fine but then I got a "Snap Server 18000" and a "Snap disk 30sa" sata array. When I turn the Snap on, it boots past the BIOS, runs a kernel, then displays: This device cannot be managed via the video/kbd/mouse interface. The video is now disabled. You may access the management functions from your web browser. Only, none of the other PCs detect it, so no browser can find it! I have checked all cables, and all LEDs indicate there's a connection. I have installed the windows "iscsi" and the adaptec "Snap Server Manager" on all PCs but still it's not detected. I don't know what else to do, please advise!

    Read the article

  • best storage option for recording live streaming video

    - by Alchemical
    We're creating a new web site that includes video chat capabilities. Wowza Server is being used for the streaming media. We would like the capability for users to record their video chats in certain circumstances. Is it feasible to record the videos to the same server running Wowza? Or performance-wise, would it make more sense to store them on another server? I understand SANs are popular as well, but I'm a little concerned about cost for those as we are on a fairly tight budget. Currently we have two servers with pretty decent RAID cnofigurations for storage, one has 14TB and the other 6TB. Mostly concerned if doing the recording on the same server as the streaming server (or web server), could significantly adversely affect that server's primary function.

    Read the article

  • Best practice for assigning private IP ranges?

    - by Tauren
    Is it common practice to use certain private IP address ranges for certain purposes? I'm starting to look into setting up virtualization systems and storage servers. Each system has two NICs, one for public network access, and one for internal management and storage access. Is it common for businesses to use certain ranges for certain purposes? If so, what are these ranges and purposes? Or does everyone do it differently? I just don't want to do it completely differently from what is standard practice in order to simplify things for new hires, etc.

    Read the article

  • Can you use your own drives on Dell PowerVault MD3000i?

    - by Chris
    I would like to use my own drives in the Dell PowerVault MD3000i. Does anyone know if you are able to? We are looking at different SANs for our VM farm and would rather be able to replace a drive in 10 minutes. This will also reduce the cost of drives significantly. Also, if anyone has any good experience with other SANs that let you use your own drives. Thank you.

    Read the article

  • alias name in brocade

    - by wildchild
    how do i look for alias name using the WWN in brocade. Say i have created an alias "CentosNode2Port1" using switch show i get the WWN ,but how to look for the alias name. alishow (WWN) is not accepting. please help

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • What is good book for administration & configuration of Storage logical arrays?

    - by unknown (yahoo)
    I am looking for a book which can explain pros and cons of different combination of configurations/policies of storage Arrays and may also suggest some best practices for certain scenarios for e.g. when data availability & security is very important. There are a lot of "books for dummy" but they don't go in depth, I am a more of developer so I would like to understand how and why exactly it works beneath policies & configuration settings. I am working with EMC clarion logical array but I will have to work with EMC Symmetrix or NetApp or any other types of disk arrays.

    Read the article

  • How to get multipath working for Ubuntu Server 12.04

    - by mlampi
    I'm working on a project which aims to make use of Ubuntu servers running on enterprise class hardware. In our case that means IBM HS23E blade servers, QLogic 4GB fibre channel extension cards and quite old IBM DS4500 disk array with two controllers. At the moment we have fibre channel as only boot option and Ubuntu Server 12.04 installed just fine and is able to boot without multipath. I'm not a linux professional myself but in our team we have people who will understand the technical stuff. Don't let my post confuse :) The current situation is that we have only one fibre channel connection to a single disk array controller. Real life case would be of course quite different. At minimum we should have two fibre channel ports connected to two different switches and two different controllers. However, we have no idea how to set up multipath tool. Is the DM-MPIO the right software? At minimum we should be able to boot when multiple connections are available and achieve fault tolerance when any of them should be down. Since the disk array is not the latest hardware, I managed to find RDAC driver sources only for 2.6.x kernel. And we have 3.2.x. Another issue is to build a multipath.conf. The said driver sources are from IBM support and the QLogic drivers provided to Ubuntu installer are from Ubuntu site. It seems that RHEL and SLES would have near out of the box support but that is not an option for our project. Actual questions: - What is the recommended software tool for multipath for Ubuntu Server 12.04? - Is there available pre-made configurations or templates? Does it require disk array / controller specific settings or do a more generic config work? - Do you have expriences on similar setup and like to share the knowledge? I'll provide you with any additional information you might require. Thanks in advance.

    Read the article

  • Cannot login to ISCSI Target - hangs after sending login details

    - by Frank
    I have an ISCSI target volume, to which i am trying to connect using CentOS Linux server. Everything works fine, but cannot its stuck at login. Here are the steps i am performing: [root@neon ~]# iscsiadm -m node -l iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session20 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session21 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session22 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session23 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session30 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session31 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session78 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session79 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session80 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session81 Logging in to [iface: eql.eth2, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260] (multiple) After this step, its stucks, waits for some time and then gives this output: Logging in to [iface: iface1, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260] (multiple) iscsiadm: Could not login to [iface: eql.eth2, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260]. My iscsi.conf is this: node.startup = automatic node.session.timeo.replacement_timeout = 15 # default 120; RedHat recommended node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 5 node.session.err_timeo.abort_timeout = 15 node.session.err_timeo.lu_reset_timeout = 20 node.session.initial_login_retry_max = 8 # default 8; Dell recommended node.session.cmds_max = 1024 # default 128; Equallogic recommended node.session.queue_depth = 32 # default 32; Equallogic recommended node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 discovery.sendtargets.iscsi.MaxRecvDataSegmentLength = 32768 node.conn[0].iscsi.HeaderDigest = None node.session.iscsi.FastAbort = Yes Also, in access control, i have given full access to Any IP, Any CHAP user and fixed iscsi initiator name. With same access level, all other volumes on rest of servers are working, except this one.

    Read the article

  • What does this mean: "SATP VMW_SATP_LOCAL does not support device configuration"?

    - by Jason Tan
    Can anyone tell me what this means in ESXi 5.1?: SATP VMW_SATP_LOCAL does not support device configuration I've googled it and I get a lot of results, but as yet all the pages that contain the string are discussing other matters. The storage array is a HDS HUS-VM and the hosts are HP b460c G8 blades with flex fabric and flex fabric VCs which I am in the process of commissioning and would like to get it started on the right foot - i.e. error and warning free! naa.600508b1001c56ee3d70da65f071da23 Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c56ee3d70da65f071da23) Storage Array Type: VMW_SATP_LOCAL Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Path Selection Policy: VMW_PSP_FIXED Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L1;current=vmhba0:C0:T0:L1} Path Selection Policy Device Custom Config: Working Paths: vmhba0:C0:T0:L1 Is Local SAS Device: true Is Boot USB Device: false This is the same LUN: ~ # esxcli storage core device list -d naa.60060e80132757005020275700000016 naa.60060e80132757005020275700000016 Display Name: HITACHI Fibre Channel Disk (naa.60060e80132757005020275700000016) Has Settable Display Name: true Size: 204800 Device Type: Direct-Access Multipath Plugin: NMP Devfs Path: /vmfs/devices/disks/naa.60060e80132757005020275700000016 Vendor: HITACHI Model: OPEN-V Revision: 5001 SCSI Level: 2 Is Pseudo: false Status: degraded Is RDM Capable: true Is Local: false Is Removable: false Is SSD: false Is Offline: false Is Perennially Reserved: false Queue Full Sample Size: 0 Queue Full Threshold: 0 Thin Provisioning Status: unknown Attached Filters: VAAI_FILTER VAAI Status: supported Other UIDs: vml.020001000060060e801327570050202757000000164f50454e2d56 Is Local SAS Device: false Is Boot USB Device: false ~ #

    Read the article

  • ESXi boot time with 9 iSCSI targets

    - by Myles Gray
    Our ESXi hosts have always been slow booting when it came to iscsi_vmk loaded successfully - sitting here for almost 5 minutes. In all a full server reboot takes almost 12 minutes. We have 9 iSCSI targets per host (5 SANs with redundant interfaces) configured as dynamic discovery targets. Has anyone experienced this? Can it be remedied with static discovery mode? Are there any debug steps we can work through to help diagnose this? (All our targets are accessible at boot so i'm assuming the host isn't stuck retrying to connect to a target)

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >