Search Results

Search found 518 results on 21 pages for 'vbscript'.

Page 8/21 | < Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >

  • VB Script and filename with space

    - by Ram
    Hi I wrote a VBS file to open the "6 May" folder with following content path = "F:\Test\2010\May\6 May" Set Sh = CreateObject("WSCript.Shell") Sh.Run ""path"",3,True Set Sh = Nothing However on executing this I am getting following error Windows Script Host Script: F:\Sperry\2010\May_06 May\open.vbs Line: 4 Char: 10 Error: Expected end of statement Code: 800A0401 Source: Microsoft VBScript compilation error OK Can anyone help me in this?

    Read the article

  • summer training

    - by rohit-garg
    hi i wanna make a retail store software for my family retail store .... can anyone help me out with which language to use and just give me some basic ideas I'm an engineering student and have good knowledge of ASP, HTML, CSS, VBSCRIPT and have gone through java , c ,c++. please help me anyone

    Read the article

  • Task Scheduler not running .bat or .vbs successfully

    - by Django Reinhardt
    Hi there, got this weird problem, which will hopefully have an obvious solution for some enlightened soul: We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs script stopped successfully executing... but oddly it worked fine when ran manually! The error given in these circumstances was always "Timeout". We thought we try a little creative thinking, and run the .vbs another way: Via a .bat file. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file is nothing more than... CScript "C:\location\script.vbs" > Log.txt But the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The log.txt file says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • Task Scheduler not able to execute .vbs scripts successfully

    - by Django Reinhardt
    Apologies if this has a really obvious answer! We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs scripts stopped successfully executing (always timing out)... but could still be executed manually with no problems(!). Not knowing any good reason why the Task Scheduler should start having problems, we thought we'd try a little "creative thinking", and run the .vbs another way: Via a .bat file executed by the Task Scheduler. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file run by Task Scheduler is nothing more than... CScript "C:\location\script.vbs" > Log.txt But after an attempt to run it, the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The Log.txt (as output from the .bat file above) says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • WS2008 subst in Logon script does not "stick"

    - by Frans
    I have a terminal server environment exclusively with Windows Server 2008. My problem is that I need to "map" a drive letter to each users Temp folder. This is due to a legacy app that requries a separate Temp folder for each user but which does not understand %temp%. So, just add "subst t: %temp%" to the logon script, right? The problem is that, even though the command runs, the subst doesn't "stick" and the user doesn't get a T: drive. Here is what I have tried; The simplest version: 'Mapping a temp drive Set WinShell = WScript.CreateObject("WScript.Shell") WinShell.Run "subst T: %temp%", 2, True That didn't work, so tried this for more debug information: 'Mapping a temp drive Set WinShell = WScript.CreateObject("WScript.Shell") Set procEnv = WinShell.Environment("Process") wscript.echo(procEnv("TEMP")) tempDir = procEnv("TEMP") WinShell.Run "subst T: " & tempDir, 3, True This shows me the correct temp path when the user logs in - but still no T: Drive. Decided to resort to brute force and put this in my login script: 'Mapping a temp drive Set WinShell = WScript.CreateObject("WScript.Shell") WinShell.Run "\\domain\sysvol\esl.hosted\scripts\tempdir.cmd", 3, True where \domain\sysvol\esl.hosted\scripts\tempdir.cmd has this content: echo on subst t: %temp% pause When I log in with the above then the command window opens up and I can see the subst command being executed correctly, with the correct path. But still no T: drive. I have tried running all of the above scripts outside of a login script and they always work perfectly - this problem only occurs when doing it from inside a login script. I found a passing reference on an MSFN forum about a similar problem when the user is already logged on to another machine - but I have this problem even without being logged on to another machine. Any suggestion on how to overcome this will be much appreciated.

    Read the article

  • IIS7 bulk bindings in vbscript , how to remove a binding

    - by minus4
    I have a script to manage adding over a thousand domains to a single site bindings, this has gone fine, but now client wants about 20 of them removed, Microsoft programmers don't think it would be nice to sort the bindings alphabetically, so does anyone know the code to remove the domains ( array list ) in bulk please. this is what i am using: Set adminManager = createObject("Microsoft.ApplicationHost.WritableAdminManager") adminManager.CommitPath = "MACHINE/WEBROOT/APPHOST" Set sitesSection = adminManager.GetAdminSection("system.applicationHost/sites", "MACHINE/WEBROOT/APPHOST") Set sitesCollection = sitesSection.Collection siteElementPos = FindElement(sitesCollection, "site", Array("name", "microsites")) If siteElementPos = -1 Then WScript.Echo "Element not found!" WScript.Quit End If on error resume next Set siteElement = sitesCollection.Item(siteElementPos) Set bindingsCollection = siteElement.ChildElements.Item("bindings").Collection Dim arrFileNames : arrFileNames = Array("list of domains") Dim objDict : Set objDict = CreateObject("Scripting.Dictionary") Dim strFileName, strTemp For Each strFileName In arrFileNames Set bindingElement = bindingsCollection.CreateNewElement("binding") bindingElement.Properties.Item("protocol").Value = "http" bindingElement.Properties.Item("bindingInformation").Value = "192.168.100.19:80:" & strFileName bindingsCollection.AddElement(bindingElement) Next adminManager.CommitChanges() WScript.Echo "Job Completed" WScript.Quit Function FindElement(collection, elementTagName, valuesToMatch) For i = 0 To CInt(collection.Count) - 1 Set element = collection.Item(i) If element.Name = elementTagName Then matches = True For iVal = 0 To UBound(valuesToMatch) Step 2 Set property = element.GetPropertyByName(valuesToMatch(iVal)) value = property.Value If Not IsNull(value) Then value = CStr(value) End If If Not value = CStr(valuesToMatch(iVal + 1)) Then matches = False Exit For End If Next If matches Then Exit For End If End If Next If matches Then FindElement = i Else FindElement = -1 End If End Function so as you can see it is easy to add, but i can find no code or manual or instructions for the removal. i cant seem to run appcmd either. at first i tried creating a batch file using the appcmd but this never worked, saying appcmd can not be found. thanks

    Read the article

  • 2 VB Scripts one to remove Default Gateway and one to add a Default Gateway

    - by Tom
    Hello everyone, I have a client with a bunch of children using about 30 machines on a regular basis. All machines that the children user are set with Static IP Addresses. The machines that the kids use, I would like to be able to run a script that will remove the default gateway so they cant get to the Internet. Then I need another that will add the Default gateway, so Windows and software updates can be run. Both scripts need to use the domain admin account for permissions Any help would be greatly appreciated

    Read the article

  • Task Scheduler not able to execute .vbs successfully

    - by Django Reinhardt
    Hi there, got this weird problem, which will hopefully have an obvious solution for some enlightened soul: We have several daily tasks we run via a .vbs script on our server (through the Task Scheduler), and for months it has been fine, but recently we've hit a problem. The .vbs script stopped successfully executing... but oddly it worked fine when ran manually! The error given in these circumstances was always "Timeout". We thought we try a little creative thinking, and run the .vbs another way: Via a .bat file. Again we hit weird issues, but with a little more debugging information, this time around. The .bat file is nothing more than... CScript "C:\location\script.vbs" > Log.txt But the Task Scheduler fails with the following error: 0x1: An incorrect function was called or an unknown function was called. The log.txt file says: CScript Error: Initialization of the Windows Script Host failed. (Not enough storage is available to process this command. ) But get this: The .bat file executes perfectly (vbs script and all) if it's executed with a double click! There's only a problem when it's run by Task Scheduler. What the hell? We're running Windows Server 2008 R2 (x64) and yes, the Task Sheduler's results are the same whether the user is logged in or not. Also, the user that can run the scripts successfully manually, is also the same user that runs the scripts in Task Scheduler. Thanks for any help for this weird problem!

    Read the article

  • Windows shutdown processes termination sequence

    - by jpmartins
    I've seen today an wierd situation. I have a theory, but it would help to know more about the windows shutdown process. If you have some knowlaged about it please share. A machine was shutdown (at this moment I suspect an unexpected mantainace), on that machine there was a long running process that was interrupted. Monitorization confirms that the process did not terminated normally. Loking at the logs for the long running process it seem that was just finishing. That seems higly unprobable since it was running for more than 6 hours (witch is a bit more than the usual 5 hours). The process lanches child processes and waits for results from them, I suspect pour error control on the parent process and that the shutdown as terminated child processes before.

    Read the article

  • cmd files to hta

    - by Frode Eskil
    I have a lot of cmd files i use daily for example to add users to local groups, installing printers, run as admin tasks etc. I like to take the scripts i use most frequently and add them to a tabbed hta file, but i have trouble finding a good guide on how to easily do it. Anyone having a good site to share with me? Or do i finally have to start with vb scripting? I have done some but it's so much faster to do a cmd file for me.

    Read the article

  • wait for the second VB script untill ended from primary VB script

    - by yael
    Hi I have VB script that run second VB script The second VB script ask some questions from the input box My problem is that “MyShell.Run” not wait until SecondVBscript.vbs will ended And the Other VB syntax run immodestly also Need to wait for MyShell.Run process ended and then perform the Other VB syntax How can I do that? Set MyShell = Wscript.CreateObject("WScript.Shell") MyShell.Run " C:\Program Files\SecondVBscript.vbs" Set MyShell = Nothing Other VB syntax

    Read the article

  • Script to kill process at logoff doesn't execute until process is dead?

    - by robertc
    We have a program that, due to memory leaks in some of the screens, doesn't exit cleanly when the user quits. The problem is that this blocks the normal logoff procedure - you select logout and a few processes disappear but the user doesn't actually log off. Since I'm unable to fix the program, I thought I'd use a script run at logoff to kill the process. I've verified the script kills the process if I run it by double clicking and have added the script to Windows Settings - Scripts - Logoff on my machine in gpedit. Unfortunately it seems that the logoff scripts don't get run until all the processes have died, so it never runs. Is there a way to make the logoff scripts run at an earlier point in the process? Or is there a better approach to the issue?

    Read the article

  • Modify MDT wizard to automate computer naming

    - by Jeramy
    I originally posted this question to StackOverflow, but upon further consideration it might be more appropriate here. Situation: I am imaging new systems using MDT Lite-Touch. I am trying to customize the wizard to automate the naming of new systems so that they include a prefix "AG-", a department code which is selected from a drop-down box in the wizard page (eg. "COMM"), and finally the serial number of the computer being imaged, so that my result in this case would be "AG-COMM-1234567890" Status: I have banged away at this for a while but my Google searches have not turned up answers, my trial-and-error is not producing useful error messages and I think I am missing some fundamentals of how to get variables from the wizard page into the variables used by the lite-touch wizard. Progress: I first created the HTML page which I will include below and added a script to the page to concatenate the pieces into a variable called OSDComputername which, for testing, I could output in a msgbox and get to display correctly. The problem with this is I don't know how to trigger the script then assign it to the OSDComputername variable that is used throughout the rest of the Light-Touch process. I changed the script to a function and added it to DeployWiz_Initization.vbs then used the Initialization field in WDS to call it. I'll include the function below. The problem with this is I would get "Undefined Variable" for OSDComputername and I am not sure it is pulling the data from the HTML correctly. I tried adding the scripting into the customsettings.ini file after the "OSDComputername=" This resulted in the wizard just outputting my code in text as the computer name. I am now trying adding variables to "Properties=" (eg.DepartmentName) in the customsettings.ini, pulling thier value from the HTML Form and setting that value to the variable in my function in DeployWiz_Initization.vbs and calling them after "OSDComputername=" in the fashion "OSDComputername="AG-" & %DepartmentName%" in customsettings.ini I am rebuilding right now and will see how this goes Any help would be appreciated. The HTML page: <HTML> <H1>Configure the computer name.</H1> <span style="width: 95%;"> <p>Please answer the following questions. Your answers will be used to formulate the computer's name and description.</p> <FORM NAME="TestForm"> <p>Departmental Prefix: <!-- <label class=ErrMsg id=DepartmentalPrefix_Err>* Required (MISSING)</label> --> <SELECT NAME="DepartmentalPrefix_Edit" class=WideEdit> <option value="AADC">AADC</option> <option value="AEM">AEM</option> <option value="AIP">AIP</option> <option value="COM">COM</option> <option value="DO">DO</option> <option value="DSOC">DSOC</option> <option value="EDU">EDU</option> <option value="EPE">EPE</option> <option value="ITN">ITN</option> <option value="LA">LA</option> <option value="OAP">OAP</option> <option value="SML">SML</option> </SELECT> </p> <p><span class="Larger">Client's Net<u class=larger>I</u>D:</span> <INPUT NAME="ClientNetID" TYPE="TEXT" ID="ClientNetID" SIZE="15"></p> <p>Building: <!-- <label class=ErrMsg id=Building_Err>* Required (MISSING)</label> --> <SELECT NAME="Building_Edit" class=WideEdit> <option value="Academic Surge Facility A">Academic Surge Facility A</option> <option value="Academic Surge Facility B">Academic Surge Facility B</option> <option value="Caldwell">Caldwell</option> <option value="Kennedy">Kennedy</option> <option value="Roberts">Roberts</option> <option value="Warren">Warren</option> </SELECT> </p> <p> <span class="Larger">Room <u class=larger>N</u>umber:</span> <input type=text id="RoomNumber" name=RoomNumber size=15 /> </p> </FORM> </span> </HTML> The Function: Function SetComputerName OSDComputerName = "AG-" & oEnvironment.Item("DepartmentalPrefix_Edit") ComputerDescription = oEnvironment.Item("DepartmentalPrefix_Edit") & ", " & oEnvironment.Item("ClientNetID") & ", " & oEnvironment.Item("RoomNumber") & " " & oEnvironment.Item("Building_Edit") End Function

    Read the article

  • Script to wrap around an application and wait for app to finish

    - by JohnyV
    I need a vb script that will wrap around an applcation which will stay open until the application finishes. I want to be able to call the following command "setup.exe /qb /I Autocad2010.ini /language en-us" But I need the vb script to stay running until the setup has finished. Is there anyone out there that can assist with this. Much appreciated in advance

    Read the article

  • create print server port via command line error Win 8

    - by Benjamin Jones
    I need to create a Print Server Port via commandline in Windows 8 Per Google search I should be using prnport.vbs script to do so: cscript c:\Windows\System32\Printing_Admin_Scripts\en-US\prnport.vbs -a -s \\192.168.113.253 -r Xerox_192.168.113.253 However I get this error: ** Unable to connect to WMI service Error 0x800706BA The RPC Server is unavailable. ** I looked at local services and both RPC and WMI services are started . Also I made sure add remote admin rule to Windows Firewall via command line without success!: netsh advfirewall firewall set rule group="windows management instrumentation (wmi)" new enable=yes netsh advfirewall firewall set rule group="remote administration" new enable=yes NOTE: If I use the GUI to create the print server port then add the printer via command line: rundll32 printui.dll,PrintUIEntry /if /b "Xerox WorkCenter 7535" /F C:\Windows\Inf\WC7545-7556_PCL6_x64_Driver\x2DNORX.inf /r "Xerox_192.168.113.253" /m "Xerox WorkCentre 7535 PCL6" THE PRINTER IS SUCCESSFULLY ADDED. So its NOT the printer it self! So how can I successfully add a print server port via command line? Thanks

    Read the article

  • Disable "Windows Firewall with Advanced Security" for all profiles(Domain,Public,Standard) in local GP using script help! Windows 7 Clients

    - by JoBo
    We need Windows7 with windows firewall to be turned off , so the GOLD image has windows firewall turned off for all profiles(Domain,Public,Standard) and Windows Service disabled No the same GOLD image deployed with MDT (Apply local GPO) has enabled Windows Firewall under "Windows Firewall with Advanced Security" as part of task sequence Now we need to remove it. "These machines are now on Domain where in we have no rights/control on the domain level GPO", we have local admi rights on these machines We have a requirement do set the "Windows Firewall with Advanced Security" to "NOT Configured" or "OFF "on these machines In gpedit.msc if we manually go to "Windows Firewall with Advanced Security" after enabling Windows Firewall Services then can Clear the settings Do do the same manually on all machines is extra effort Changing values in registry will get reverted on machine restart as its getting applied from local GPO Also using GPMC can connect to remote computer and can manually or using wfw file we can make it not configured but we are looking for a script or a less effort method to accomplish this Please suggest NB: CIA has already reported similar issue//How do I turn off Windows 7 Firewall via script or through automation?// , but doing netsh advfirewall set allprofiles state off on already deployed machines did not make change (FW service on all machine is disabled in GOLd image)// Thanks and Regards Jose

    Read the article

  • Why won't my logon scripts map drives under Windows 7?

    - by Steven
    Why won't my logon scripts map drives under Windows 7? I'm using a vb script similar to the one below, the script runs using a group policy. Dim WshNetwork Set WshNetwork = WScript.CreateObject("WScript.Network") WshNetwork.MapNetworkDrive "g:", "\\\Saturn\data\" WshNetwork.MapNetworkDrive "k:", "\\\Saturn\stuff\" Works fine for Windows XP. Update: Copying the script locally and running it runs fine so I suspect the Group Policy isn't running the script on Windows 7. Many thanks Steve

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >