Search Results

Search found 13904 results on 557 pages for 'host on demand'.

Page 84/557 | < Previous Page | 80 81 82 83 84 85 86 87 88 89 90 91  | Next Page >

  • Approach for parsing file and creating dynamic data structure for use by another program

    - by user275633
    All, Background: I have a customer who has some build scripts for their datacenter based on python that I've inherited. I did not work on the original design so I'm sort of limited to some degree on what I can and can't change. That said, my customer has a properties file that they use in their datacenter. Some of the values are used to build their servers and unfortunately they have other applications that also use these values so I cannot change them to make it easier for me. What I want to do is make the scripts more dynamic to distribute more hosts so that I don't have to keep updating the scripts in the future and can just add more hosts to the property file. Unfortunately I can't change the current property file and have to work with it. The property file looks something like this: projectName.ClusterNameServer1.sslport=443 projectName.ClusterNameServer1.port=80 projectName.ClusterNameServer1.host=myHostA projectName.ClusterNameServer2.sslport=443 projectName.ClusterNameServer2.port=80 projectName.ClusterNameServer2.host=myHostB In their deployment scripts they basically have alot of if projectName.ClusterNameServerX where X is some number of entries defined and then do something, e.g.: if projectName.ClusterNameServer1.host != "" do X if projectName.ClusterNameServer2.host != "" do X if projectName.ClusterNameServer3.host != "" do X Then when they add another host (say Serve4) they've added another if statement. Question: What I would like to do is make the scripts more dynamic and parse the properties file and put what I need into some data structure to pass to the deployment scripts and then just iterate over the structure and do my deployment that way so I don't have to constantly add a bunch of if some host# do something. I'm just curious to feed some suggestions as to what others would do to parse the file and what sort of data structure would they use and how they would group things together by ClusterNameServer# or something else. Thanks

    Read the article

  • The Benefits of Smart Grid Business Software

    - by Sylvie MacKenzie, PMP
    Smart Grid Background What Are Smart Grids?Smart Grids use computer hardware and software, sensors, controls, and telecommunications equipment and services to: Link customers to information that helps them manage consumption and use electricity wisely. Enable customers to respond to utility notices in ways that help minimize the duration of overloads, bottlenecks, and outages. Provide utilities with information that helps them improve performance and control costs. What Is Driving Smart Grid Development? Environmental ImpactSmart Grid development is picking up speed because of the widespread interest in reducing the negative impact that energy use has on the environment. Smart Grids use technology to drive efficiencies in transmission, distribution, and consumption. As a result, utilities can serve customers’ power needs with fewer generating plants, fewer transmission and distribution assets,and lower overall generation. With the possible exception of wind farm sprawl, landscape preservation is one obvious benefit. And because most generation today results in greenhouse gas emissions, Smart Grids reduce air pollution and the potential for global climate change.Smart Grids also more easily accommodate the technical difficulties of integrating intermittent renewable resources like wind and solar into the grid, providing further greenhouse gas reductions. CostsThe ability to defer the cost of plant and grid expansion is a major benefit to both utilities and customers. Utilities do not need to use as many internal resources for traditional infrastructure project planning and management. Large T&D infrastructure expansion costs are not passed on to customers.Smart Grids will not eliminate capital expansion, of course. Transmission corridors to connect renewable generation with customers will require major near-term expenditures. Additionally, in the future, electricity to satisfy the needs of population growth and additional applications will exceed the capacity reductions available through the Smart Grid. At that point, expansion will resume—but with greater overall T&D efficiency based on demand response, load control, and many other Smart Grid technologies and business processes. Energy efficiency is a second area of Smart Grid cost saving of particular relevance to customers. The timely and detailed information Smart Grids provide encourages customers to limit waste, adopt energy-efficient building codes and standards, and invest in energy efficient appliances. Efficiency may or may not lower customer bills because customer efficiency savings may be offset by higher costs in generation fuels or carbon taxes. It is clear, however, that bills will be lower with efficiency than without it. Utility Operations Smart Grids can serve as the central focus of utility initiatives to improve business processes. Many utilities have long “wish lists” of projects and applications they would like to fund in order to improve customer service or ease staff’s burden of repetitious work, but they have difficulty cost-justifying the changes, especially in the short term. Adding Smart Grid benefits to the cost/benefit analysis frequently tips the scales in favor of the change and can also significantly reduce payback periods.Mobile workforce applications and asset management applications work together to deploy assets and then to maintain, repair, and replace them. Many additional benefits result—for instance, increased productivity and fuel savings from better routing. Similarly, customer portals that provide customers with near-real-time information can also encourage online payments, thus lowering billing costs. Utilities can and should include these cost and service improvements in the list of Smart Grid benefits. What Is Smart Grid Business Software? Smart Grid business software gathers data from a Smart Grid and uses it improve a utility’s business processes. Smart Grid business software also helps utilities provide relevant information to customers who can then use it to reduce their own consumption and improve their environmental profiles. Smart Grid Business Software Minimizes the Impact of Peak Demand Utilities must size their assets to accommodate their highest peak demand. The higher the peak rises above base demand: The more assets a utility must build that are used only for brief periods—an inefficient use of capital. The higher the utility’s risk profile rises given the uncertainties surrounding the time needed for permitting, building, and recouping costs. The higher the costs for utilities to purchase supply, because generators can charge more for contracts and spot supply during high-demand periods. Smart Grids enable a variety of programs that reduce peak demand, including: Time-of-use pricing and critical peak pricing—programs that charge customers more when they consume electricity during peak periods. Pilot projects indicate that these programs are successful in flattening peaks, thus ensuring better use of existing T&D and generation assets. Direct load control, which lets utilities reduce or eliminate electricity flow to customer equipment (such as air conditioners). Contracts govern the terms and conditions of these turn-offs. Indirect load control, which signals customers to reduce the use of on-premises equipment for contractually agreed-on time periods. Smart Grid business software enables utilities to impose penalties on customers who do not comply with their contracts. Smart Grids also help utilities manage peaks with existing assets by enabling: Real-time asset monitoring and control. In this application, advanced sensors safely enable dynamic capacity load limits, ensuring that all grid assets can be used to their maximum capacity during peak demand periods. Real-time asset monitoring and control applications also detect the location of excessive losses and pinpoint need for mitigation and asset replacements. As a result, utilities reduce outage risk and guard against excess capacity or “over-build”. Better peak demand analysis. As a result: Distribution planners can better size equipment (e.g. transformers) to avoid over-building. Operations engineers can identify and resolve bottlenecks and other inefficiencies that may cause or exacerbate peaks. As above, the result is a reduction in the tendency to over-build. Supply managers can more closely match procurement with delivery. As a result, they can fine-tune supply portfolios, reducing the tendency to over-contract for peak supply and reducing the need to resort to spot market purchases during high peaks. Smart Grids can help lower the cost of remaining peaks by: Standardizing interconnections for new distributed resources (such as electricity storage devices). Placing the interconnections where needed to support anticipated grid congestion. Smart Grid Business Software Lowers the Cost of Field Services By processing Smart Grid data through their business software, utilities can reduce such field costs as: Vegetation management. Smart Grids can pinpoint momentary interruptions and tree-caused outages. Spatial mash-up tools leverage GIS models of tree growth for targeted vegetation management. This reduces the cost of unnecessary tree trimming. Service vehicle fuel. Many utility service calls are “false alarms.” Checking meter status before dispatching crews prevents many unnecessary “truck rolls.” Similarly, crews use far less fuel when Smart Grid sensors can pinpoint a problem and mobile workforce applications can then route them directly to it. Smart Grid Business Software Ensures Regulatory Compliance Smart Grids can ensure compliance with private contracts and with regional, national, or international requirements by: Monitoring fulfillment of contract terms. Utilities can use one-hour interval meters to ensure that interruptible (“non-core”) customers actually reduce or eliminate deliveries as required. They can use the information to levy fines against contract violators. Monitoring regulations imposed on customers, such as maximum use during specific time periods. Using accurate time-stamped event history derived from intelligent devices distributed throughout the smart grid to monitor and report reliability statistics and risk compliance. Automating business processes and activities that ensure compliance with security and reliability measures (e.g. NERC-CIP 2-9). Grid Business Software Strengthens Utilities’ Connection to Customers While Reducing Customer Service Costs During outages, Smart Grid business software can: Identify outages more quickly. Software uses sensors to pinpoint outages and nested outage locations. They also permit utilities to ensure outage resolution at every meter location. Size outages more accurately, permitting utilities to dispatch crews that have the skills needed, in appropriate numbers. Provide updates on outage location and expected duration. This information helps call centers inform customers about the timing of service restoration. Smart Grids also facilitates display of outage maps for customer and public-service use. Smart Grids can significantly reduce the cost to: Connect and disconnect customers. Meters capable of remote disconnect can virtually eliminate the costs of field crews and vehicles previously required to change service from the old to the new residents of a metered property or disconnect customers for nonpayment. Resolve reports of voltage fluctuation. Smart Grids gather and report voltage and power quality data from meters and grid sensors, enabling utilities to pinpoint reported problems or resolve them before customers complain. Detect and resolve non-technical losses (e.g. theft). Smart Grids can identify illegal attempts to reconnect meters or to use electricity in supposedly vacant premises. They can also detect theft by comparing flows through delivery assets with billed consumption. Smart Grids also facilitate outreach to customers. By monitoring and analyzing consumption over time, utilities can: Identify customers with unusually high usage and contact them before they receive a bill. They can also suggest conservation techniques that might help to limit consumption. This can head off “high bill” complaints to the contact center. Note that such “high usage” or “additional charges apply because you are out of range” notices—frequently via text messaging—are already common among mobile phone providers. Help customers identify appropriate bill payment alternatives (budget billing, prepayment, etc.). Help customers find and reduce causes of over-consumption. There’s no waiting for bills in the mail before they even understand there is a problem. Utilities benefit not just through improved customer relations but also through limiting the size of bills from customers who might struggle to pay them. Where permitted, Smart Grids can open the doors to such new utility service offerings as: Monitoring properties. Landlords reduce costs of vacant properties when utilities notify them of unexpected energy or water consumption. Utilities can perform similar services for owners of vacation properties or the adult children of aging parents. Monitoring equipment. Power-use patterns can reveal a need for equipment maintenance. Smart Grids permit utilities to alert owners or managers to a need for maintenance or replacement. Facilitating home and small-business networks. Smart Grids can provide a gateway to equipment networks that automate control or let owners access equipment remotely. They also facilitate net metering, offering some utilities a path toward involvement in small-scale solar or wind generation. Prepayment plans that do not need special meters. Smart Grid Business Software Helps Customers Control Energy Costs There is no end to the ways Smart Grids help both small and large customers control energy costs. For instance: Multi-premises customers appreciate having all meters read on the same day so that they can more easily compare consumption at various sites. Customers in competitive regions can match their consumption profile (detailed via Smart Grid data) with specific offerings from competitive suppliers. Customers seeing inexplicable consumption patterns and power quality problems may investigate further. The result can be discovery of electrical problems that can be resolved through rewiring or maintenance—before more serious fires or accidents happen. Smart Grid Business Software Facilitates Use of Renewables Generation from wind and solar resources is a popular alternative to fossil fuel generation, which emits greenhouse gases. Wind and solar generation may also increase energy security in regions that currently import fossil fuel for use in generation. Utilities face many technical issues as they attempt to integrate intermittent resource generation into traditional grids, which traditionally handle only fully dispatchable generation. Smart Grid business software helps solves many of these issues by: Detecting sudden drops in production from renewables-generated electricity (wind and solar) and automatically triggering electricity storage and smart appliance response to compensate as needed. Supporting industry-standard distributed generation interconnection processes to reduce interconnection costs and avoid adding renewable supplies to locations already subject to grid congestion. Facilitating modeling and monitoring of locally generated supply from renewables and thus helping to maximize their use. Increasing the efficiency of “net metering” (through which utilities can use electricity generated by customers) by: Providing data for analysis. Integrating the production and consumption aspects of customer accounts. During non-peak periods, such techniques enable utilities to increase the percent of renewable generation in their supply mix. During peak periods, Smart Grid business software controls circuit reconfiguration to maximize available capacity. Conclusion Utility missions are changing. Yesterday, they focused on delivery of reasonably priced energy and water. Tomorrow, their missions will expand to encompass sustainable use and environmental improvement.Smart Grids are key to helping utilities achieve this expanded mission. But they come at a relatively high price. Utilities will need to invest heavily in new hardware, software, business process development, and staff training. Customer investments in home area networks and smart appliances will be large. Learning to change the energy and water consumption habits of a lifetime could ultimately prove even more formidable tasks.Smart Grid business software can ease the cost and difficulties inherent in a needed transition to a more flexible, reliable, responsive electricity grid. Justifying its implementation, however, requires a full understanding of the benefits it brings—benefits that can ultimately help customers, utilities, communities, and the world address global issues like energy security and climate change while minimizing costs and maximizing customer convenience. This white paper is available for download here. For further information about Oracle's Primavera Solutions for Utilities, please read our Utilities e-book.

    Read the article

  • nokia cell phone not accepting IP from dnsmasq dhcp server

    - by samix
    Hello, I having problem connecting a NOkia cell phone to my home wifi network. The wifi network is provided by a wireless card in a machine running Debian Testing and 2.6.26-2-686 kernel. The cars is D-Link DWL-G520 working in ap mode and has WPA encryption enabled. The wireless network is provided by hostapd using madwifi driver. Windows and Mac machines work properly with this wifi network. When I try to get the Nokia phone to connect to the wifi network, I get these lines in my dnsmasq log (to see lines without wrapping, here is the pastebin link for convenience - http://pastebin.com/m466c8fd2): Oct 27 13:25:21 red hostapd: ath0: STA 11:22:33:44:55:66 IEEE 802.11: disassociated Oct 27 13:25:21 red hostapd: ath0: STA 11:22:33:44:55:66 IEEE 802.11: associated Oct 27 13:25:21 red hostapd: ath0: STA 11:22:33:44:55:66 RADIUS: starting accounting session 4AE664FA-00000036 Oct 27 13:25:21 red hostapd: ath0: STA 11:22:33:44:55:66 WPA: pairwise key handshake completed (WPA) Oct 27 13:25:21 red hostapd: ath0: STA 11:22:33:44:55:66 WPA: group key handshake completed (WPA) Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 Available DHCP range: 192.168.5.150 -- 192.168.5.199 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 DHCPDISCOVER(ath0) 0.0.0.0 11:22:33:44:55:66 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 DHCPOFFER(ath0) 192.168.5.21 11:22:33:44:55:66 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 requested options: 12:hostname, 6:dns-server, 15:domain-name, Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 requested options: 1:netmask, 3:router, 28:broadcast, 120:sip-server Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 tags: known, ath0 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 next server: 192.168.5.1 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 1 option: 53:message-type 02 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 54:server-identifier 192.168.5.1 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 51:lease-time 00:00:46:50 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 58:T1 00:00:23:28 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 59:T2 00:00:3d:86 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 1:netmask 255.255.255.0 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 28:broadcast 192.168.5.255 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 3:router 192.168.5.1 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 4 option: 6:dns-server 192.168.5.1 Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 8 option: 15:domain-name home.pvt Oct 27 13:25:21 red dnsmasq-dhcp[11451]: 3875439214 sent size: 3 option: 12:hostname NokiaCellPhone Anybody know the problem might be? If I switch off dnsmasq dhcp queries logging, i.e. if I decrease the verbosity of the log, all I see are two lines of DHCPDISCOVER(ath0) and DHCPOFFER(ath0) repeatedly in the log with no acceptance by the cell phone. It appears as though the phone is not accepting the dhcp offer. However, if I give the phone a static IP address in its configuration, it works properly on the wifi network. So it appears as though the problem is dhcp related. Hints? Suggestions? Installed stuff: $ dpkg -l dnsmasq hostap* | grep ^i ii dnsmasq 2.50-1 A small caching DNS proxy and DHCP/TFTP server ii dnsmasq-base 2.50-1 A small caching DNS proxy and DHCP/TFTP server ii hostapd 1:0.6.9-3 user space IEEE 802.11 AP and IEEE 802.1X/WPA/ Thanks. PS: Here is the DHCP tcp dump for more information (with mac addresses changed): $ sudo dhcpdump -i ath0 -h ^11:22:33:44:55:66 TIME: 2009-10-30 12:15:32.916 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 0 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:32.918 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 0 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:32.918 IP: 192.168.5.1 (a:bb:cc:dd:ee:ff) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 2 (BOOTPREPLY) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 0 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 192.168.5.21 SIADDR: 192.168.5.1 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 2 (DHCPOFFER) OPTION: 54 ( 4) Server identifier 192.168.5.1 OPTION: 51 ( 4) IP address leasetime 18000 (5h) OPTION: 58 ( 4) T1 9000 (2h30m) OPTION: 59 ( 4) T2 15750 (4h22m30s) OPTION: 1 ( 4) Subnet mask 255.255.255.0 OPTION: 28 ( 4) Broadcast address 192.168.5.255 OPTION: 3 ( 4) Routers 192.168.5.1 OPTION: 6 ( 4) DNS server 192.168.5.1 OPTION: 15 ( 8) Domainname home.pvt OPTION: 12 ( 3) Host name Nokia_E63 TIME: 2009-10-30 12:15:34.922 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 2 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:34.922 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 2 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:34.923 IP: 192.168.5.1 (a:bb:cc:dd:ee:ff) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 2 (BOOTPREPLY) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 2 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 192.168.5.21 SIADDR: 192.168.5.1 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 2 (DHCPOFFER) OPTION: 54 ( 4) Server identifier 192.168.5.1 OPTION: 51 ( 4) IP address leasetime 18000 (5h) OPTION: 58 ( 4) T1 9000 (2h30m) OPTION: 59 ( 4) T2 15750 (4h22m30s) OPTION: 1 ( 4) Subnet mask 255.255.255.0 OPTION: 28 ( 4) Broadcast address 192.168.5.255 OPTION: 3 ( 4) Routers 192.168.5.1 OPTION: 6 ( 4) DNS server 192.168.5.1 OPTION: 15 ( 8) Domainname home.pvt OPTION: 12 ( 3) Host name Nokia_E63 TIME: 2009-10-30 12:15:38.919 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 6 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:38.920 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 6 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:38.921 IP: 192.168.5.1 (a:bb:cc:dd:ee:ff) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 2 (BOOTPREPLY) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: c3f93d53 SECS: 6 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 192.168.5.21 SIADDR: 192.168.5.1 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 2 (DHCPOFFER) OPTION: 54 ( 4) Server identifier 192.168.5.1 OPTION: 51 ( 4) IP address leasetime 18000 (5h) OPTION: 58 ( 4) T1 9000 (2h30m) OPTION: 59 ( 4) T2 15750 (4h22m30s) OPTION: 1 ( 4) Subnet mask 255.255.255.0 OPTION: 28 ( 4) Broadcast address 192.168.5.255 OPTION: 3 ( 4) Routers 192.168.5.1 OPTION: 6 ( 4) DNS server 192.168.5.1 OPTION: 15 ( 8) Domainname home.pvt OPTION: 12 ( 3) Host name Nokia_E63 TIME: 2009-10-30 12:15:46.944 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: ccafe769 SECS: 14 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:46.944 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: ccafe769 SECS: 14 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 0.0.0.0 SIADDR: 0.0.0.0 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 1 (DHCPDISCOVER) OPTION: 50 ( 4) Request IP address 0.0.0.0 OPTION: 61 ( 7) Client-identifier 01:11:22:33:44:55:66 OPTION: 55 ( 7) Parameter Request List 12 (Host name) 6 (DNS server) 15 (Domainname) 1 (Subnet mask) 3 (Routers) 28 (Broadcast address) 120 (SIP Servers DHCP Option) OPTION: 57 ( 2) Maximum DHCP message size 576 TIME: 2009-10-30 12:15:46.945 IP: 192.168.5.1 (a:bb:cc:dd:ee:ff) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 2 (BOOTPREPLY) HTYPE: 1 (Ethernet) HLEN: 6 HOPS: 0 XID: ccafe769 SECS: 14 FLAGS: 7f80 CIADDR: 0.0.0.0 YIADDR: 192.168.5.21 SIADDR: 192.168.5.1 GIADDR: 0.0.0.0 CHADDR: 11:22:33:44:55:66:00:00:00:00:00:00:00:00:00:00 SNAME: . FNAME: . OPTION: 53 ( 1) DHCP message type 2 (DHCPOFFER) OPTION: 54 ( 4) Server identifier 192.168.5.1 OPTION: 51 ( 4) IP address leasetime 18000 (5h) OPTION: 58 ( 4) T1 9000 (2h30m) OPTION: 59 ( 4) T2 15750 (4h22m30s) OPTION: 1 ( 4) Subnet mask 255.255.255.0 OPTION: 28 ( 4) Broadcast address 192.168.5.255 OPTION: 3 ( 4) Routers 192.168.5.1 OPTION: 6 ( 4) DNS server 192.168.5.1 OPTION: 15 ( 8) Domainname home.pvt OPTION: 12 ( 3) Host name Nokia_E63 TIME: 2009-10-30 12:15:48.952 IP: 0.0.0.0 (1:22:33:44:55:66) 255.255.255.255 (ff:ff:ff:ff:ff:ff) OP: 1 (BOOTPREQUEST) HTYPE: 1 (Ethernet) HLEN: 6 ... and so on ...

    Read the article

  • Header set Access-Control-Allow-Origin not working with mod_rewrite + mod_jk

    - by tharant
    My first question on here on SF so please forgive me if I manage to bork the post. :) Anyways, I'm using mod_rewrite on one of my machines with a simple rule that redirects to a webapp on another machine. I'm also setting the header 'Access-Control-Allow-Origin' on both machines. The problem is that when I hit the rewrite rule, I loose the 'Access-Control-Allow-Origin' header setting. Here's an example of the Apache config for the first machine: NameVirtualHost 10.0.0.2:80 <VirtualHost 10.0.0.2:80> DocumentRoot /var/www/host.example.com ServerName host.example.com JkMount /webapp/* jkworker Header set Access-Control-Allow-Origin "*" RewriteEngine on RewriteRule ^/otherhost http://otherhost.example.com/webapp [R,L] </VirtualHost> And here's an example of the Apache config for the second: NameVirtualHost 10.0.1.2:80 <VirtualHost 10.0.1.2:80> DocumentRoot /var/www/otherhost.example.com ServerName otherhost.example.com JkMount /webapp/* jkworker Header set Access-Control-Allow-Origin "*" </VirtualHost> When I hit host.example.com we see that the header is set: $ curl -i http://host.example.com/ HTTP/1.1 302 Moved Temporarily Server: Apache/2.2.11 (FreeBSD) mod_ssl/2.2.11 OpenSSL/0.9.7e-p1 DAV/2 mod_jk/1.2.26 Content-Length: 0 Access-Control-Allow-Origin: * Content-Type: text/html;charset=ISO-8859-1 And when I hit otherhost.example.com we see that it too is setting the header: $ curl -i http://otherhost.example.com HTTP/1.1 200 OK Server: Apache/2.0.46 (Red Hat) Location: http://otherhost.example.com/index.htm Content-Length: 0 Access-Control-Allow-Origin: * Content-Type: text/html;charset=UTF-8 But when I try to hit the rewrite rule at host.example.com/otherhost we get no love: $ curl -i http://host.example.com/otherhost/ HTTP/1.1 302 Found Server: Apache/2.2.11 (FreeBSD) mod_ssl/2.2.11 OpenSSL/0.9.7e-p1 DAV/2 mod_jk/1.2.26 Location: http://otherhost.example.com/ Content-Length: 0 Content-Type: text/html; charset=iso-8859-1 Can anybody point out what I'm doing wrong here? Could mod_jk be part of the problem?

    Read the article

  • Ubuntu 12.04 LDAP SSL self-signed cert not accepted

    - by MaddHacker
    I'm working with Ubuntu 12.04, using OpenLDAP server. I've followed the instructions on the Ubuntu help pages and can happily connect without security. To test my connection, I'm using ldapsearch the command looks like: ldapsearch -xv -H ldap://ldap.[my host].local -b dc=[my domain],dc=local -d8 -ZZ I've also used: ldapsearch -xv -H ldaps://ldap.[my host].local -b dc=[my domain],dc=local -d8 As far as I can tell, I've setup my certificate correctly, but no matter why I try, I can't seem to get ldapsearch to accept my self-signed certificate. So far, I've tried: Updating my /etc/ldap/ldap.conf file to look like: BASE dc=[my domain],dc=local URI ldaps://ldap.[my host].local TLS_CACERT /etc/ssl/certs/cacert.crt TLS_REQCERT allow Updating my /etc/ldap.conf file to look like: base dc=[my domain],dc=local uri ldapi:///ldap.[my host].local uri ldaps:///ldap.[my host].local ldap_version 3 ssl start_tls ssl on tls_checkpeer no TLS_REQCERT allow Updating my /etc/default/slapd to include: SLAPD_SERVICES="ldap:/// ldapi:/// ldaps:///" Several hours of Googling, most of which resulted in adding the TLS_REQCERT allow The exact error I'm seeing is: ldap_initialize( ldap://ldap.[my host].local ) request done: ld 0x20038710 msgid 1 TLS certificate verification: Error, self signed certificate in certificate chain TLS: can't connect. ldap_start_tls: Connect error (-11) additional info: error:14090086:SSL routines:SSL3_GET_SERVER_CERTIFICATE:certificate verify failed After several hours of this, I was hoping someone else has seen this issue, and/or knows how to fix it. Please do let me know if I should add more information, or if you need further data.

    Read the article

  • Can't setup 3 nodes MongoDB recplica set

    - by Victor Lin
    I just follow instructions in MongoDB document Replica Sets - Basics to setup a 3-node Replica set. Everything goes fine when I do the initiate and add first node in the primary. [foo@host-a mongodb]$ bin/mongo localhost MongoDB shell version: 1.8.2 connecting to: localhost > rs.initiate() { "info2" : "no configuration explicitly specified -- making one", "info" : "Config now saved locally. Should come online in about a minute.", "ok" : 1 } > rs.add("host-b") { "ok" : 1 } So far so good, but when I try to add third node myset:PRIMARY> rs.addArb("host-c") Sun Aug 7 22:57:09 MessagingPort recv() errno:104 Connection reset by peer 127.0.0.1:27017 Sun Aug 7 22:57:09 SocketException: remote: error: 9001 socket exception [1] Sun Aug 7 22:57:09 DBClientCursor::init call() failed Sun Aug 7 22:57:09 query failed : local.$cmd { count: "system.replset", query: {}, fields: {} } to: 127.0.0.1 Sun Aug 7 22:57:09 Error: error doing query: failed shell/collection.js:150 Sun Aug 7 22:57:09 trying reconnect to 127.0.0.1 Sun Aug 7 22:57:09 reconnect 127.0.0.1 ok As result, the current primary became secondary, and the host-b was marked as dead, but actually, it is still alive. myset:SECONDARY> rs.status() { "set" : "myset", "date" : ISODate("2011-08-08T04:03:23Z"), "myState" : 2, "members" : [ { "_id" : 0, "name" : "host-a:27017", "health" : 1, "state" : 2, "stateStr" : "SECONDARY", "optime" : { "t" : 1312775799000, "i" : 1 }, "optimeDate" : ISODate("2011-08-08T03:56:39Z"), "self" : true }, { "_id" : 1, "name" : "host-b", "health" : 0, "state" : 6, "stateStr" : "(not reachable/healthy)", "uptime" : 0, "optime" : { "t" : 0, "i" : 0 }, "optimeDate" : ISODate("1970-01-01T00:00:00Z"), "lastHeartbeat" : ISODate("2011-08-08T04:03:22Z"), "errmsg" : "still initializing" } ], "ok" : 1 } How could this happen? I just follow the guide in the document, did I do something wrong? Moreover, I can't do anything on current secondary server. It doesn't allow me to reconfig on the secondary node, but the problem is there is no primary node. myset:SECONDARY> rs.reconfig({}) { "errmsg" : "replSetReconfig command must be sent to the current replica set primary.", "ok" : 0 } Any ideas?

    Read the article

  • SNAT through Racoon IPSec VPN

    - by Mite fine d'ailes
    I am trying to route traffic from a device (that I will call "target") connected to my Ubuntu box (that I will call "host") to servers at a remote office. The host uses a Racoon IPSec VPN, connected through a NIC called efix. This creates an aliased IF called efix:0 which has IP adress 192.168.190.132. It is able to reach the servers. The link between host and target is an Ethernet link, using IP adresses 10.0.0.1 on IF eusb for the host and 10.0.0.2 on IF eth0 for the target. I have setup the following routes and iptables entries: On target: 10.0.0.0 * 255.255.255.0 U 0 0 0 eth0 default 10.0.0.1 0.0.0.0 UG 0 0 0 eth0 On host: echo 1 > /proc/sys/net/ipv4/ip_forward iptables -t nat -A POSTROUTING -s 10.0.0.0/24 -j SNAT --to 192.168.190.132 iptables -A FORWARD -s 10.0.0.0/24 -j ACCEPT iptables -A FORWARD -d 10.0.0.0/24 -j ACCEPT Using Wireshark to monitor an HTTP GET, I can see SYN packets from the target go all the way to the server, but the server's SYNACK packets stop at the host and are not forwarded to the target. Am I missing something here ? Isn't SNAT supposed to keep track of the connections ?

    Read the article

  • Make dhcp assign same IP and hostname for different interfaces at one machine

    - by Egeshi
    I have a feeling that question itself looks stupid but it is not. Please let me clarify. I have dynamic DNS with BIND and NIS configured at my LAN and have laptop which I am using in both wireless and wired mode. I mean that sometimes I have to use wired interface to achieve higher throughput but most of time I don't need it and using wireless mode. Everything works great. Issue is that I want both interfaces get same IP from DHCP. Just for convenient firewall setup. If I add both hosts to dhcp in this manner # bt wireless host bt { hardware ethernet 00:1f:1f:62:60:28; fixed-address 172.16.77.110; } # bt wired host bt { hardware ethernet 00:14:22:b7:5a:de; fixed-address 172.16.77.110; } DHCP says logs following message dhcpd: Dynamic and static leases present for 172.16.77.110 dhcpd: Remove host declaration bt-wired or remove 172.16.77.110 dhcpd: from the dynamic address pool for 172.16/16 Host records are added outside of any subnet, but it makes no difference if I put them there, effect is still the same. This is not critical but either is not my whim because even if DHCP seems to work fine for that "bt" host, I cannot make connection TO it from remote machine anymore with this definitely incorrect DHCP config. I'd be thankful if one spares a minute for advice about how to configure DHCPD correctly. UPDATE. I realize that there's a soulution to assign different hostname in DHCP config but would like to use benefits of short host names.

    Read the article

  • How to add commands of windows to local shell of XShell 4

    - by dylanninin
    XShell is a very powerful tools to ssh remote computers such as Unix/Linux. And it has built some internal commands for you to run within your Windows. Xshell:\> help Internal Commands: new: Creates a new session. open: Opens a session or the session dialog box. edit: Opens the Session Property dialog box for a session. list: Lists information of all available sessions. 'ls' and 'dir' do the same. cd: Changes the current working directory. clear: Clears the screen/address/command history. help: Displays this help. '?' does the same. quit: Quits Local Shell. 'exit' does the same. ssh: Connects to a host using the SSH protocol. telnet: Connects to a host using the TELNET protocol. rlogin: Connects to a host using the RLOGIN protocol. sftp: Connects to a host to transfer files securely. ftp: Connects to a host to transfer files. External Commands: ipconfig: Configures TCP/IP network interfaces. ping: Sends ICMP ECHO_REQUEST packets to network hosts. tracert: Prints the route packets take to network host. netstat: Displays current protocol statistics and current TCP/IP network connections. nslookup: Resolves a hostname to IP address. For more information, type 'help command' for each command. ex) help telnet But these commands are limited, so how to add commands of windows to local shell of XShell 4

    Read the article

  • ownCloud WebDAV interface seems to be broken

    - by Nobleleader13245
    I've been trying to host ownCloud on my server but everytime I try to it tells me this : Your web server is not yet properly setup to allow files synchronization because the WebDAV interface seems to be broken. Please double check the installation guides. This is my setup : Windows Server 2012 R2 IIS 8.5 PHP 5.5.11 ownCloud 6.0.3 MySQL 5.6.17 I tried google the error but I can't seem to find anything usefull. Some say I should try if this works : [hostname]/remote.php/webdav/ and yes I can navigate to this folder and I can open files from there. The calendar works and I can also just upload files the web version of ownCloud the only thing that doesn't seem to work is the sync client. The sync client doesn't say anything it just doesn't connect (Screenshot : http://prntscr.com/3p2apz) This is the error log : Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:56:00+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:55:47+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:55:34+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:55:34+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:37+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:36+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:36+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:36+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:51:24+00:00 This is my php.ini : http://pastebin.com/es3MB8Uh Does anyone have any idea on how I should get this to work? I've been trying to get this to work for about 14 days now and it starts to annoy me =P

    Read the article

  • ownCloud WebDAV interface seems to be broken

    - by Nobleleader13245
    I've been trying to host ownCloud on my server but everytime I try to it tells me this : Your web server is not yet properly setup to allow files synchronization because the WebDAV interface seems to be broken. Please double check the installation guides. This is my setup : Windows Server 2012 R2 IIS 8.5 PHP 5.5.11 ownCloud 6.0.3 MySQL 5.6.17 I tried google the error but I can't seem to find anything usefull. Some say I should try if this works : https://cloud.mcsoftworks.net/remote.php/webdav/ and yes I can navigate to this folder and I can open files from there. The calendar works and I can also just upload files from here https://cloud.mcsoftworks.net/ the only thing that doesn't seem to work is the sync client. The sync client doesn't say anything it just doesn't connect (Screenshot : http://prntscr.com/3p2apz) This is the error log : Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:56:00+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:55:47+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:55:34+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:55:34+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:37+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:36+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:36+00:00 Fatal webdav Sabre_DAV_Exception_Forbidden: Path does not exist, or escaping from the base path was detected 2014-06-02T19:54:36+00:00 Warning core isWebDAVWorking: NO - Reason: [CURL] Error while making request: Could not resolve host: cloud.mcsoftworks.net (error code: 6) (Sabre_DAV_Exception) 2014-06-02T19:51:24+00:00 This is my php.ini : http://pastebin.com/es3MB8Uh Does anyone have any idea on how I should get this to work? I've been trying to get this to work for about 14 days now and it starts to annoy me =P

    Read the article

  • VPS with Plesk, one ip, and godaddy (definely need help)

    - by Francesco
    Hi there, here's my situation : i've Plesk 8.3.0 with one IP and i've registered my domains at godaddy.com My problem : i cannot figure out how to configure plesk and godaddy to have my domains (6) properly working into the VPS. i've only one IP, so i can't have my personal NS and need to use godaddy ns. But.. how do i set all the stuff ? I've made a try but it's not working. Please take a look : This is an example of how the domain i'm actually working on is configured On Plesk : Host Record type Value 1.2.3.4 / 24 PTR mydomain.com. ftp.mydomain.com. CNAME mydomain.com. mail.mydomain.com. A 1.2.3.4 ns.mydomain.com. A 1.2.3.4 mydomain.com. NS ns.mydomain.com. mydomain.com. A 1.2.3.4 mydomain.com. MX (10) mail.mydomain.com. webmail.mydomain.com. A 1.2.3.4 www.mydomain.com. CNAME mydomain.com. On godaddy,(Total DNS Control) for the same domain i have this setup : A (Host) Host Points To TTL Actions * 1.2.3.4 1 Hour CNAMES (Aliases) Host Points To TTL Actions e email.secureserver.net 1 Hour email email.secureserver.net 1 Hour ftp @ 1 Hour imap imap.secureserver.net 1 Hour mail pop.secureserver.net 1 Hour mobilemail mobilemail-v01.prod.mesa1.secureserver.net 1 Hour pda mobilemail-v01.prod.mesa1.secureserver.net 1 Hour pop pop.secureserver.net 1 Hour smtp smtp.secureserver.net 1 Hour webmail webmail.secureserver.net 1 Hour www @ 1 Hour MX (Mail Exchange) Priority Host Goes To TTL Actions 10 @ mailstore1.secureserver.net 1 Hour 0 @ smtp.secureserver.net Host Points To TTL Actions @ ns53.domaincontrol.com @ ns54.domaincontrol.com What should i correct ? Thanks for helping me Francesco

    Read the article

  • ssh over a tunnel in order to configure auto login

    - by Vihaan Verma
    I m trying to copy the id_rsa.pub key to the server. The server in my case also has a virutal machine called dev which runs on the host machine. I copied the id_rsa.pub key to the host for auto log in using this command. ssh-copy-id -i ~/.ssh/id_rsa.pub vickey@host which worked fine and I can auto log in to host. I also wanted to auto log in to the dev machine. I know I can just copy the contents of authorized_keys from the host machine to the dev machine but I m looking for a command line of doing things. Creating a tunnel seemed like the solution ssh vickey@host -L 2000:dev:22 -N now when I tried ssh-copy-id -i ~/.ssh/id_rsa.pub vickey@localhost -P 2000 the password that worked here was of my local machine , I expected it to ask me password of my dev machine. The above command adds the pub key to the local machine and not to the dev machine. However this commands asks me for the dev password and copies the files. scp -P 2000 vickey@localhost:/home/vickey/trash/vim . vickey@localhost's password: vim 100% 111 0.1KB/s 00:00 How do I do the same with ssh-copy-id ?

    Read the article

  • JBD: Spotted dirty metadata buffer

    - by Jake Mach
    Sep 25 22:19:38 host kernel: [7798806.146942] JBD: Spotted dirty metadata buffer (dev = loop0, blocknr = 267). There's a risk of filesystem corruption in case of system crash. Sep 25 22:19:38 host kernel: [7798806.146956] JBD: Spotted dirty metadata buffer (dev = loop0, blocknr = 1). There's a risk of filesystem corruption in case of system crash. Sep 25 22:19:38 host kernel: [7798806.146967] JBD: Spotted dirty metadata buffer (dev = loop0, blocknr = 353). There's a risk of filesystem corruption in case of system crash. Sep 25 22:19:38 host kernel: [7798806.147121] JBD: Spotted dirty metadata buffer (dev = loop0, blocknr = 353). There's a risk of filesystem corruption in case of system crash. Sep 25 22:19:38 host kernel: [7798806.147133] JBD: Spotted dirty metadata buffer (dev = loop0, blocknr = 1). There's a risk of filesystem corruption in case of system crash. Sep 25 22:19:38 host kernel: [7798806.147143] JBD: Spotted dirty metadata buffer (dev = loop0, blocknr = 267). There's a risk of filesystem corruption in case of system crash. [7817859.850517] EXT4-fs error (device loop0): ext4_mb_generate_buddy: EXT4-fs: group 1: 28618 blocks in bitmap, 29028 in gd what does this mean? how did this happen?

    Read the article

  • Pattern matching gnmap fields with SED

    - by Ovid
    I am testing the regex needed for creating field extraction with Splunk for nmap and think I might be close... Example full line: Host: 10.0.0.1 (host) Ports: 21/open|filtered/tcp//ftp///, 22/open/tcp//ssh//OpenSSH 5.9p1 Debian 5ubuntu1 (protocol 2.0)/, 23/closed/tcp//telnet///, 80/open/tcp//http//Apache httpd 2.2.22 ((Ubuntu))/, 10000/closed/tcp//snet-sensor-mgmt/// OS: Linux 2.6.32 - 3.2 Seq Index: 257 IP ID Seq: All zeros I've used underscore "_" as the delimiter because it makes it a little easier to read. root@host:/# sed -n -e 's_\([0-9]\{1,5\}\/[^/]*\/[^/]*\/\/[^/]*\/\/[^/]*\/.\)_\n\1_pg' filename The same regex with the escape characters removed: root@host:/# sed -n -e 's_\([0-9]\{1,5\}/[^/]*/[^/]*//[^/]*//[^/]*/.\)_\n\1_pg' filename Output: ... ... ... Host: 10.0.0.1 (host) Ports: 21/open|filtered/tcp//ftp///, 22/open/tcp//ssh//OpenSSH 2.0p1 Debian 2ubuntu1 (protocol 2.0)/, 23/closed/tcp//telnet///, 80/open/tcp//http//Apache httpd 5.4.32 ((Ubuntu))/, 10000/closed/tcp//snet-sensor-mgmt/// OS: Linux 9.8.76 - 7.3 Seq Index: 257 IPID Seq: All zeros ... ... ... As you can see, the pattern matching appears to be working - although I am unable to: 1 - match on both the end of line ( comma , and white/tabspace). The last line contains unwanted text (in this case, the OS and TCP timing info) and 2 - remove any of the un-necessary data - i.e. print only the matching pattern. It is actually printing the whole line. If i remove the sed -n flag, the remaining file contents are also printed. I can't seem to locate a way to only print the matched regex. Being fairly new to sed and regex, any help or pointers is greatly appreciated!

    Read the article

  • Website memory problem

    - by Toktik
    I have CentOS 5 installed on my server. I'm in VPS server. I have site where I have constant online ~150. First look on site looks OK. But when I go through links, sometimes I receive Out of memory PHP error. It looks like this Fatal error: Out of memory (allocated 36962304) (tried to allocate 7680 bytes) in /home/host/public_html/sites/all/modules/cck/modules/fieldgroup/fieldgroup.install on line 100 And always, not allocated memory is very small. In average I have 30% CPU load, 25% RAM load. So I think here is not a physical memory problem. My PHP memory limit was set to 1500MB. My apache error log looks like this [Thu Sep 30 17:48:59 2010] [error] [client 91.204.190.5] Out of memory, referer: http://www.host.com/17402 [Thu Sep 30 17:48:59 2010] [error] [client 91.204.190.5] Premature end of script headers: index.php, referer: http://www.host.com/17402 [Thu Sep 30 17:48:59 2010] [error] [client 91.204.190.5] Out of memory, referer: http://www.host.com/17402 [Thu Sep 30 17:48:59 2010] [error] [client 91.204.190.5] Premature end of script headers: index.php, referer: http://www.host.com/17402 [Thu Sep 30 17:49:00 2010] [error] [client 91.204.190.5] File does not exist: /home/host/public_html/favicon.ico Past I have not met with this on my server and the problem appeared itself. Besides this I'm receiving some server errors on mail. cpsrvd failed @ Fri Sep 24 16:45:20 2010. A restart was attempted automagically. Service Check Method: [tcp connect] Failure Reason: Unable to connect to port 2086 Same for tailwatchd. Support tried, and can't help me...

    Read the article

  • Troubleshooting a Windows 7 PC that wouldn't sleep

    - by NPE
    I have a new Windows 7 PC that wouldn't sleep (not just automatically, but also when specifically told to). The screen goes black momentarily, but within two seconds the machine comes back as if nothing has happened. I tried powercfg energy. This produces some errors quoted at the bottom of this post, plus some warnings about timer resolution. There are no USB devices connected other than wireless keyboard + mouse (Logitech MK250); I tried unplugging them to no effect. The motherboard is Asus P7P55D-E. powercfg lastwake says "Wake History Count - 0", which I take to mean that it never actually went to sleep. I dual boot into Ubuntu, and was having exactly the same problem on the Linux side. That turned out to do with USB 3.0, which I've now disabled in the BIOS. This has solved the problem on the Ubuntu side of things, but made no difference to Windows 7. Any suggestions? Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name Generic USB Hub Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_8087&PID_0020 Port Path 1 USB Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name USB Root Hub Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_8086&PID_3B34 Port Path USB Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name USB Composite Device Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_046D&PID_C52E Port Path 1,8

    Read the article

  • Nmap XML parsing with Powershell

    - by Craig620
    I am trying to parse the XML output from NMAP and isolate just the hostadddress and the vendor from the osmatch. I've actually done that with the following: select-xml -path nmap.xml -xpath "nmaprun/host/address/@addr|nmaprun/host/os/osmatch/osclass/@vendor" | select -expandproperty node Which produces: #text ----- 10.20.30.1 HP 10.20.30.2 Linux 10.20.30.3 HP What I was not expecting is that it would jam it all into a single column.Silly me would like the address in one column, and the vendor in another column. I Would like: #addr #vendor ----- ------- 10.20.30.1 HP 10.20.30.2 Linux 10.20.30.3 HP In the several hours I spent learning xpath today, I also realized that this file has a single address for each host, but multiple OS guesses for each host. I would also like to use only the first osGuess in the output. Tired using: -xpath "(nmaprun/host/os/osmatch/osclass/@vendor)[1]" But that truncates the whole data set to a single line of output, instead of only limiting the only the first osclass element of each host. Changing the parens to surround only the @vendor element like .../(@vendor)[1] and .../(@vendor[1]) but both fail with "Expression must evaluate to a node-set." Thanks in advance

    Read the article

  • port forwarding with socks over proxy

    - by Oz123
    I am trying to browse a wiki that runs on a server inside one domain from another domain. The wiki is accessible only on the LAN, but I need to browse it from another LAN to which I connect with an SSH tunnel ... Here is my setup and the steps I did so far: ~.ssh/confing on wikihost: Host gateway User kisteuser Port 443 Hostname gateway.companydomain.com ProxyCommand /home/myuser/bin/ssh-https-tunnel %h %p # ssh-https-tunnel: # http://ttcplinux.sourceforge.net/tools/stunnel Protocol 2 IdentityFile ~/.ssh/key_dsa LocalForward 11069 localhost:11069 Host server1 User kisteuser Hostname localhost Port 11069 LocalForward 8022 server1:22 LocalForward 17001 server1:7100 LocalForward 8080 www-proxy:3128 RemoteForward 11069 localhost:22 from wikihost myuser@wikihost: ssh -XC -t gateway.companydomain.com ssh -L11069:localhost:22 server1 on another terminal: ssh gateway.companydomain.com Now, on my companydomain I would like to start firefox and browse the wiki on wikihost. I did: [email protected] ~ $ ssh gateway Have a lot of fun... kisteuser@gateway ~ $ ssh -D 8383 localhost user@localhost's password: user@wikiserver:~> My .ssh/config on that side looks like that: host server1 localforward 11069 localhost:11069 host localhost user myuser port 11069 host wikiserver forwardagent yes user myuser port 11069 hostname localhost Now, I started firefox on the server called gateway, and edited the proxy settings to use SOCKSv5, specifying that the proxy should be gateway and use the port 8383... kisteuser@gateway ~ $ LANG=C firefox -P --no-remote And, now I get the following error popping in the Terminal of wikiserver: myuser@wikiserver:~> channel 3: open failed: connect failed: Connection refused channel 3: open failed: connect failed: Connection refused channel 3: open failed: connect failed: Connection refused Confused? Me too ... Please help me understand how to properly build the tunnels and browse the wiki over SOCKS protocol. update: I managed to browse the wiki on wikiserver with the following changes: host wikiserver forwardagent yes user myuser port 11069 hostname localhost localforward 8339 localhost:8443 Now when I ssh gateway I launch Firefox and go to localhost:8339 and I hit the start page of the wiki, which is served on Port 8443. Now I ask myself is SOCKS really needed? Can someone elaborate on that ?

    Read the article

  • SSH Private Key Not Working in Some Directories

    - by uesp
    I have a strange issue where SSH won't properly connect with a private-key if the key file is in certain directories. I've setup the keys on a set of servers and the following command ssh -i /root/privatekey [email protected] works fine and I login to the given host without getting prompted by a password, but this command: ssh -i /etc/keyfiles/privatekey [email protected] gives me a password prompt. I've narrowed it down that this behavior occurs in only some sub-directories of /etc/. For example /etc/httpd1/ gives me a password prompt but /etc/httpd/ does not. What I've checked so far: All private key files used are identical (copied from the original file). The private key file and directories used have identical permissions. No relevant error messages in the server/client logs. No interesting debug messages from ssh -v (it just seems to skip the key file). It happens with connecting to different hosts. After more testing it is not the actual directory name. For example: mkdir /etc/test cp /root/privatekey /etc/test ssh -i /etc/test/privatekey [email protected] # Results in password prompt cp /root/privatekey /etc/httpd # Existing directory ls -ald test httpd # drwxr-xr-x 4 root root 4096 Mar 5 18:25 httpd # drwxr-xr-x 2 root root 4096 Mar 5 18:43 test ssh -i /etc/httpd/privatekey [email protected] # Results in *no* prompt rm -r test cp -R /etc/httpd /etc/test ssh -i /etc/test/privatekey [email protected] # Results in *no* prompt` I'm sure its just something simple I've overlooked but I'm at a loss.

    Read the article

  • ipv6 with KVM on debian

    - by Eliasdx
    I have trouble setting up IPV6 on my Proxmox (KVM) server: My ISP sent me this information(xxx=placeholder): IPs: 2a01:XXX:XXX:301:: /64 Gateway: 2a01:XXX:XXX:300::1 /59 This is the interface setup on the host server: auto vmbr1 iface vmbr1 inet static address 178.XX.XX.4 broadcast 178.XX.XX.63 netmask 255.255.255.192 pointopoint 178.XX.XX.1 gateway 178.XX.XX.1 bridge_ports eth0 bridge_stp off bridge_fd 0 iface vmbr1 inet6 static address 2a01:XXX:XXX:301::2 netmask 64 up ip -6 route add 2a01:XXX:XXX:300::1 dev vmbr1 down ip -6 route del 2a01:XXX:XXX:300::1 dev vmbr1 up ip -6 route add default via 2a01:XXX:XXX:300::1 dev vmbr1 down ip -6 route del default via 2a01:XXX:XXX:300::1 dev vmbr1 On the guest: auto eth0 iface eth0 inet static address 178.xx.xx.47 netmask 255.255.255.255 broadcast 178.xx.xx.63 gateway 178.xx.xx.1 pointopoint 178.xx.xx.1 iface eth0 inet6 static pre-up modprobe ipv6 address 2a01:XXX:XXX:301::2:2 netmask 64 up ip -6 route add 2a01:XXX:XXX:300::1 dev eth0 down ip -6 route del 2a01:XXX:XXX:300::1 dev eth0 up ip -6 route add default via 2a01:XXX:XXX:300::1 dev eth0 down ip -6 route del default via 2a01:XXX:XXX:300::1 dev eth0 Ipv4 works on both host and guest but Ipv6 only works "sometimes". It's up for minutes and then down again until I change something. However I can actually ping the host and the guest from both host and guest. host:~# ip -6 neigh 2a01:XXX:XXX:301::100:2 dev vmbr1 lladdr 00:50:56:00:00:e0 REACHABLE 2a01:XXX:XXX:300::1 dev vmbr1 lladdr 00:26:88:76:18:18 router STALE host:~# ip -6 route 2a01:XXX:XXX:300::1 dev vmbr1 metric 1024 mtu 1500 advmss 1440 hoplimit 4294967295 2a01:XXX:XXX:301::/64 dev vmbr1 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev vmbr0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev eth0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev vmbr1 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev tap101i1d0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 default via 2a01:XXX:XXX:300::1 dev vmbr1 metric 1024 mtu 1500 advmss 1440 hoplimit 4294967295 Does someone know why it isn't working? And is there a way to configure multiple v6 IPs from the same subnet so I can dedicate IPs to websites on a server with multiple virtualhosts?

    Read the article

  • Best NIC config when virtual servers need iSCSI storage?

    - by icky2000
    I have a Windows 2008 server running Hyper-V. There are 6 NICs on the server configured like this: NIC01 & NIC02: teamed administrative interface (RDP, mgmt, etc) NIC03: connected to iSCSI VLAN #1 NIC04: connected to iSCSI VLAN #2 NIC05: dedicated to one virtual switch for VMs NIC06: dedicated to another virtual switch for VMs The iSCSI NICs are used obviously for storage to host the VMs. I put half the VMs on the host on the switch assigned to NIC05 and the other half on the switch assigned to NIC06. We have multiple production networks that the VMs could appear on so the switch ports that NIC05 & NIC06 are connected to are trunked and we then tag the NIC on the VM for the appropriate VLAN. No clustering on this host. Now I wish to assign some iSCSI storage direct to a VM. As I see it I have 2 options: Add the iSCSI VLANs to the trunked ports (NIC05 and NIC06), add two NICs to the VM that needs iSCSI storage, and tag them for the iSCSI VLANs Create two additional virtual switches on the host. Assign one to NIC03 and one to NIC04. Add two NICs to the VM that needs iSCSI storage and let them share that path to the SAN with the host. I'm wondering about how much overhead the VLAN tagging in Hyper-V has and haven't seen any discussion about that. I'm also a bit concerned that something funky on the iSCSI-connected VM could saturate the iSCSI NICs or cause some other problem that could threaten storage access for the entire host which would be bad. Any thoughts or suggestions? How do you configure your hosts when VMs connect direct to iSCSI?

    Read the article

  • How can I keep SSH's know_hosts up to date (semi-securely)?

    - by Chas. Owens
    Just to get this out in front so I am not told not to do this: The machines in question are all on a local network with little to no internet access (they aren't even well connected to the corporate network) Everyone who has the ability to setup a man-in-the-middle attack already has root on the machine The machines are reinstalled as part of QA procedures, so having new host keys is important (we need to see how the other machines react); I am only trying to make my machine nicer to use. I do a lot of reinstalls on machines which changes their host keys. This necessitates going into ~/.ssh/known_hosts on my machine and blowing away to old key and adding the new key. This is a massive pain in the tuckus, so I have started considering ways to automate this. I don't want to just blindly accept any host key, so patching OpenSSH to ignore host keys is out. I have considered creating a wrapper around the ssh command the will detect the error coming back from ssh and present me with a prompt to delete the old key or quit. I have also considered creating a daemon that would fetch the latest host key from a machine on a whitelist (there are about twenty machines that are being constantly reinstalled) and replace the old host key in known_hosts. How would you automate this process?

    Read the article

  • ipv6 with KVM on debian

    - by Eliasdx
    I have trouble setting up IPV6 on my Proxmox (KVM) server: My ISP sent me this information(xxx=placeholder): IPs: 2a01:XXX:XXX:301:: /64 Gateway: 2a01:XXX:XXX:300::1 /59 This is the interface setup on the host server: auto vmbr1 iface vmbr1 inet static address 178.XX.XX.4 broadcast 178.XX.XX.63 netmask 255.255.255.192 pointopoint 178.XX.XX.1 gateway 178.XX.XX.1 bridge_ports eth0 bridge_stp off bridge_fd 0 iface vmbr1 inet6 static address 2a01:XXX:XXX:301::2 netmask 64 up ip -6 route add 2a01:XXX:XXX:300::1 dev vmbr1 down ip -6 route del 2a01:XXX:XXX:300::1 dev vmbr1 up ip -6 route add default via 2a01:XXX:XXX:300::1 dev vmbr1 down ip -6 route del default via 2a01:XXX:XXX:300::1 dev vmbr1 On the guest: auto eth0 iface eth0 inet static address 178.xx.xx.47 netmask 255.255.255.255 broadcast 178.xx.xx.63 gateway 178.xx.xx.1 pointopoint 178.xx.xx.1 iface eth0 inet6 static pre-up modprobe ipv6 address 2a01:XXX:XXX:301::2:2 netmask 64 up ip -6 route add 2a01:XXX:XXX:300::1 dev eth0 down ip -6 route del 2a01:XXX:XXX:300::1 dev eth0 up ip -6 route add default via 2a01:XXX:XXX:300::1 dev eth0 down ip -6 route del default via 2a01:XXX:XXX:300::1 dev eth0 Ipv4 works on both host and guest but Ipv6 only works "sometimes". It's up for minutes and then down again until I change something. However I can actually ping the host and the guest from both host and guest. host:~# ip -6 neigh 2a01:XXX:XXX:301::100:2 dev vmbr1 lladdr 00:50:56:00:00:e0 REACHABLE 2a01:XXX:XXX:300::1 dev vmbr1 lladdr 00:26:88:76:18:18 router STALE host:~# ip -6 route 2a01:XXX:XXX:300::1 dev vmbr1 metric 1024 mtu 1500 advmss 1440 hoplimit 4294967295 2a01:XXX:XXX:301::/64 dev vmbr1 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev vmbr0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev eth0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev vmbr1 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev tap101i1d0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 default via 2a01:XXX:XXX:300::1 dev vmbr1 metric 1024 mtu 1500 advmss 1440 hoplimit 4294967295 Does someone know why it isn't working? And is there a way to configure multiple v6 IPs from the same subnet so I can dedicate IPs to websites on a server with multiple virtualhosts?

    Read the article

  • Problem with Strange VMWare behaviour when shutting down guest.

    - by adza77
    Hi, I've been having a problem for a while now with VMWare Workstaion. (Originally with 6.5, but now with 7.0 and 7.0.1 too). The problem occurs when I choose to shut down a guest. VMWare itself seems to hang. If I choose to shut down a guest that's opened full screen, and during the process I minimise the screen to work on other applications in the host, often (not all the time) when I return to the guest I have a 'greyed out' screen and the system becomes unresponsive. The host O/S still seems to be working, but I am unable to switch to other applications. (I can bring up the taskbar on the host and 'see' other applications and even switch to them, but VMWare still stays 'on top' being unresponsive). I can not terminate VMWare even when windows says that the application has become unresponsive and gives me the option to terminate. VMWare stays on top, and I'm forced to either shutdown, or log off and log back on in order to regain control of my computer. This happens with both Windows 7 and Windows Vista guest operating systems (32 bit), and I have had it happen on multiple host machines, and multiple guest machines too. Current Host: Windows 7 64 bit, 8GB Ram, 500GB HDD, i7 Processor. I have been searching for more than 6 months for a solution but have found none, so finally decided to post here. Does anyone know what might be causing the problem (+or even how to minimize the VM so I can at least access any other applications and save work before forcing a logoff / reboot+) would be extrememly handly. If I know the correct keystrokes to save and close in an application on the host I can do this by task-switching to the desired app to save and close successfully, but I can't see what I'm doing because VMWare Workstation is still on-top 'greyed' out. Cheers Adam.

    Read the article

< Previous Page | 80 81 82 83 84 85 86 87 88 89 90 91  | Next Page >