Search Results

Search found 3534 results on 142 pages for 'sets'.

Page 84/142 | < Previous Page | 80 81 82 83 84 85 86 87 88 89 90 91  | Next Page >

  • Joining an Ubuntu 14.04 machine to active directory with realm and sssd

    - by tubaguy50035
    I've tried following this guide to set up realmd and sssd with active directory: http://funwithlinux.net/2014/04/join-ubuntu-14-04-to-active-directory-domain-using-realmd/ When I run the command realm –verbose join domain.company.com –user-principal=c-u14-dev1/[email protected] –unattended everything seems to connect. My sssd.conf looks like the following: [nss] filter_groups = root filter_users = root reconnection_retries = 3 [pam] reconnection_retries = 3 [sssd] domains = DOMAIN.COMPANY.COM config_file_version = 2 services = nss, pam [domain/DOMAIN.COMPANY.COM] ad_domain = DOMAIN.COMPANY.COM krb5_realm = DOMAIN.COMPANY.COM realmd_tags = manages-system joined-with-adcli cache_credentials = True id_provider = ad krb5_store_password_if_offline = True default_shell = /bin/bash ldap_id_mapping = True use_fully_qualified_names = True fallback_homedir = /home/%d/%u access_provider = ad My /etc/pam.d/common-auth looks like this: auth [success=3 default=ignore] pam_krb5.so minimum_uid=1000 auth [success=2 default=ignore] pam_unix.so nullok_secure try_first_pass auth [success=1 default=ignore] pam_sss.so use_first_pass # here's the fallback if no module succeeds auth requisite pam_deny.so # prime the stack with a positive return value if there isn't one already; # this avoids us returning an error just because nothing sets a success code # since the modules above will each just jump around auth required pam_permit.so # and here are more per-package modules (the "Additional" block) auth optional pam_cap.so However, when I try to SSH into the machine with my active directory user, I see the following in auth.log: Aug 21 10:35:59 c-u14-dev1 sshd[11285]: Invalid user nwalke from myip Aug 21 10:35:59 c-u14-dev1 sshd[11285]: input_userauth_request: invalid user nwalke [preauth] Aug 21 10:36:10 c-u14-dev1 sshd[11285]: pam_krb5(sshd:auth): authentication failure; logname=nwalke uid=0 euid=0 tty=ssh ruser= rhost=myiphostname Aug 21 10:36:10 c-u14-dev1 sshd[11285]: pam_unix(sshd:auth): check pass; user unknown Aug 21 10:36:10 c-u14-dev1 sshd[11285]: pam_unix(sshd:auth): authentication failure; logname= uid=0 euid=0 tty=ssh ruser= rhost=myiphostname Aug 21 10:36:10 c-u14-dev1 sshd[11285]: pam_sss(sshd:auth): authentication failure; logname= uid=0 euid=0 tty=ssh ruser= rhost=myiphostname user=nwalke Aug 21 10:36:10 c-u14-dev1 sshd[11285]: pam_sss(sshd:auth): received for user nwalke: 10 (User not known to the underlying authentication module) Aug 21 10:36:12 c-u14-dev1 sshd[11285]: Failed password for invalid user nwalke from myip port 34455 ssh2 What do I need to do to allow active directory users the ability to log in?

    Read the article

  • Disabled FRS replication on a DFS link, but the targets still list the replica set in their FRS conf

    - by Graeme Donaldson
    It's been a while since I've had to deal with the wonders of FRS, so I'm doing some testing to refresh my memory. This is what I've done so far. I am stuck with FRS rather than DFS-R for the moment since not all of my link targets are running R2. Created a domain-based DFS root, hosted on 4 servers. Created a DFS link under the root, targeted at 2 servers. The shares on both servers were empty. Dropped about 500MB of data into the target folder on one server and waited for replication to complete. Added/removed/modified files on both targets and confirmed that changes are replicated within a few seconds. Deleted the contents of the target folder on 1 server and waited for the other server to replicate the deletion. All of this worked perfectly, so now I want to remove my DFS link since I only created it for testing purposes. This is where it gets weird. I'm pretty sure that in the past I've disabled replication on the DFS link and after a short amount of time each target would log an info event in the FRS event log, something along the lines of "this server is no longer a member of replica set X". I have waited about 3 hours and I haven't seen this happen. ntfrsutl ds tells me that the server is not a member of any set, which is expected because when I disable replication on the link, the AD attributes on the computer object are removed. The weird part is... ntfrsutl sets still shows me the replica set, with all the properties, etc. So it seems like the FRS-related attributes of the target server's AD object are gone, but the FRS service for some reason hasn't removed the replica set. Can anyone see what I have done wrong?

    Read the article

  • Different versions of iperf for windows give totally different results

    - by Albert Mata
    Measuring TCP output from a Windows client to Solaris server: WXP SP3 with iperf 1.7.0 -- returns an average around 90Mbit Same client, same server but iperf 2.0.5 for windows -- returns an average of 8.5 Mbit Similar discrepancies have been observed connecting to other servers (W2008, W2003) It's difficult to get to some conclusions when different versions of the same tool provide vastly different results. Example below: C:\tempiperf -v (from iperf.fr) iperf version 2.0.5 (08 Jul 2010) pthreads C:\tempiperf -c solaris10 Client connecting to solaris10, TCP port 5001 TCP window size: 64.0 KByte (default) [ 3] local 10.172.181.159 port 2124 connected with 10.172.180.209 port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.2 sec 10.6 MBytes 8.74 Mbits/sec Abysmal perfomance, but now I test from the same host (Windows XP SP3 32bit and 100Mbit) to the same server (Solaris 10/sparc 64bit and 1Gbit running iperf 2.0.5 with default window of 48k) with the old iperf C:\temp1iperf -v iperf version 1.7.0 (13 Mar 2003) win32 threads C:\temp1iperf.exe -c solaris10 -w64k Client connecting to solaris10, TCP port 5001 TCP window size: 64.0 KByte [1208] local 10.172.181.159 port 2128 connected with 10.172.180.209 port 5001 [ ID] Interval Transfer Bandwidth [1208] 0.0-10.0 sec 112 MBytes 94.0 Mbits/sec So one iperf with a 64k window says 8.75Mbit and the old iperf with the same window size says 94.0Mbit. These results are constant through repeated tests. From my testing launching iperf(old) with window size "x" and iperf(new) with window size "x" instead of producing the same or very close results produce totally different results. The only difference I see is the old compiled as win32 threads vs. pthreads but parallelism (-P 10) appears to work in both. Anyone has a clue or can recommend a tool that gives results I can trust?? EDIT: Looking at traces from (old) iperf it sets the TCP Window Scale flag to 3 in the SYN packet, when I run the (new) iperf this is set to 0 in the initial packet. A quick analysis of the window size through the exchange shows the (old) iperf moving back and forth but mostly at 32k while the (new) iperf mostly keeps at 64k. Maybe it will help somebody to connect the dots.

    Read the article

  • How to restore broken Ethernet functionality on Mac G5 running Mac OS 10.4.11 (Tiger)

    - by willc2
    I had a disk error that rendered my Mac unbootable. I repaired it with Tech Tool 4, but now networking does not work. Network Preferences reports that my Ethernet cable is unplugged. I know this is bogus because when I boot from an emergency partition, networking works correctly. Furthermore, wireless networking is also broken, which I tested with a known-good Wi-Fi dongle. Whenever I try to change Network Port Configurations by creating a New or Renaming an existing one, example: I get this message in the console: Error - PortScanner - setDevice, device == nil! Error - PortScanner - setDevice, device == nil! In sets of two as shown. When I try to invoke the Network Diagnostics app, it immediately crashes. My first thought is to reinstall Tiger with the Archive and Install method so I don't have to reinstall all my applications but I have lost my Tiger installer disk. My next thought is to buy Leopard for $107 on Amazon. If there is any way I can just repair my Tiger install I would be happy to save that money, though. This is not my main machine and I am loathe to put more money into it. How can I recover my network functionality? UPDATE: I found my Tiger install disk and tried an Archive and Install. It failed with an unhelpful error message along the lines of "Can't install, try again". I tried again but had the same error. My guess is, some corrupt or missing file in my User folder is preventing migration. I have a backup created with Super Duper that is a bit out of date but will startup the machine (with functional networking). I would love to just copy over the file(s) that got messed up but I don't even know where to look. What is the likely location of the System files that would cause the aforementioned symptoms?

    Read the article

  • Windows 7 "freezes" (chills?), and then "unfreezes" after about 1 minute.

    - by gbc001
    Hi, I have an Acer Timeline 1810T netbook (4GB RAM) with Windows 7 x64. About once or twice a day, it "freezes" - the reason I put this in quotation marks is that it does not really freeze, as I you cant move mouse, etc. I can move my mouse and jump between different applications, but I cant use the applications for anything. So I can jump between notepad and Firefox, but I cant browse to a new web page. I have been trying to determine the source of this misery for a while now, and I suspect it has something to do with the hard drive - indirectly if not directly. Here are some screen shots of the resource monitor during a "freeze" and during normal operation: Freeze: http://imgur.com/Gcgq1.jpg Normal operation: imgur.com/mlHaI.jpg As you can see, CPU is fine during freeze, but the disk is going bananas.. Does anyone have an idea of what these reading means, or about the problem in general? There seems to be no specific activity that sets this off - it can be during browsing, or during media playback with nothing else open. The fact that I can see navigate to applications but not use them might suggest a hard drive problem as well? Maybe I can access the stuff that is in RAM, but not anything that would require interaction with the drive.. Very appreciative of any help!

    Read the article

  • Resize a RAID 1 volume on OSX Snow Leopard - how? (Note: software raid)

    - by Emmel
    I've scoured the Internet in search of an answer to this question, and as usual with OSX-related topics, I often don't find any deep-dive technical explanations sufficient enough to feel confident doing dangerous things. Here is my question: I have a Mac Pro, running OSX 10.6.2. I have, as my main root/boot disk, a RAID 1 volume called "Mirror1". Mirror1 is comprised of two 1 TB disks. Mirror1, however, is fixed at 640 GB. That's because, I originally took a 640GB disk, bought a terabyte disk, mirrored it (using diskutil appleraid enable...), when it synced I removed the 640GB and replaced it with a second 1 TB disk, and synced again. Voila! A single 640 GB replaced by two 1 TB disks in a mirror.. Actually, no. There's still something missing from the equation: Mirror1 needs to be expanded from 640GB to 1 TB to match the partition sizes on each of those disks. How do I do this? Perhaps the diskutil output will help: -> diskutil list /dev/disk0 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk0 1: EFI 209.7 MB disk0s1 2: Apple_RAID 999.9 GB disk0s2 3: Apple_Boot Boot OSX 134.2 MB disk0s3 /dev/disk1 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *1.0 TB disk1 1: EFI 209.7 MB disk1s1 2: Apple_RAID 999.9 GB disk1s2 3: Apple_Boot Boot OSX 134.2 MB disk1s3 /dev/disk2 #: TYPE NAME SIZE IDENTIFIER 0: GUID_partition_scheme *640.1 GB disk2 1: EFI 209.7 MB disk2s1 2: Apple_HFS Mac Disk 2 536.7 GB disk2s2 3: Microsoft Basic Data BOOTCAMP 103.1 GB disk2s3 /dev/disk3 #: TYPE NAME SIZE IDENTIFIER 0: Apple_HFS Mirror1 *639.8 GB disk3 -> diskutil appleraid list AppleRAID sets (1 found) =============================================================================== Name: Macintosh HD Unique ID: 1953F864-B474-4EB6-8E69-41834EBD0247 Type: Mirror Status: Online Size: 639.8 GB (639791038464 Bytes) Rebuild: manual Device Node: disk3 ------------------------------------------------------------------------------- # Device Node UUID Status ------------------------------------------------------------------------------- 0 disk1s2 25109BAE-5697-40EA-B612-0217851444F7 Online 1 disk0s2 11B83AB0-8148-4DB6-8761-DEF08C855F8D Online =============================================================================== Thanks in advance.

    Read the article

  • adding trac to apache2 configuration file

    - by Michael
    I currently have apache2 running from a mythtv/mythweb install. This made two config files available in sites-enabled. One of them ("default-mythbuntu") has the VirtualHost directive and seems like a normal file (except a change to the directory index). There is also a mythweb.conf file that only has directives and sets various variables for mythweb. I want to host a trac site as well. According to this site: http://trac.edgewall.org/wiki/TracOnUbuntu there are some setting I need to set for the Trac site. They give me directions for making a VirtualHost, but I think I should use the current VirtualHost and just add the directives (I'll need to change the default location they point to from the site above to just point to the trac location). Where should I put these directives? Can I make a Trac.conf with just the settings for Trac and enable it, or do I need to put them in the default-mythbuntu file? I don't like that later because it doesn't separate out the Trac configs. How does Apache know that the mythweb (and the trac.conf I want to make) belong to the virtualhost defined in the default-mythbuntu? It is the only virtualhost that is being defined on my system if that matters.

    Read the article

  • Defeating the RAID5 write hole with ZFS (but not RAID-Z) [closed]

    - by Michael Shick
    I'm setting up a long-term storage system for keeping personal backups and archives. I plan to have RAID5 starting with a relatively small array and adding devices over time to expand storage. I may also want to convert to RAID6 down the road when the array gets large. Linux md is a perfect fit for this use case since it allows both of the changes I want on a live array and performance isn't at all important. Low cost is also great. Now, I also want to defend against file corruption, so it looked like a RAID-Z1 would be a good fit, but evidently I would only be able to add additional RAID5 (RAID-Z1) sets at a time rather than individual drives. I want to be able to add drives one at a time, and I don't want to have to give up another device for parity with every expansion. So at this point, it looks like I'll be using a plain ZFS filesystem on top of an md RAID5 array. That brings me to my primary question: Will ZFS be able to correct or at least detect corruption resulting from the RAID5 write hole? Additionally, any other caveats or advice for such a set up is welcome. I'll probably be using Debian, but I'll definitely be using Linux since I'm familiar with it, so that means only as new a version of ZFS as is available for Linux (via ZFS-FUSE or so).

    Read the article

  • SQLRelay MySQL compatibility layer in php-cgi.

    - by sybreon
    I am investigating the use of sqlrelay as a middle-layer between an application that uses MySQL with a PostgreSQL backend. I assume that this is something that it can do to ease backend migration. But for the moment, I am just experimenting with a MySQL application accessing a MySQL backend through the sqlrelay layer. app => sqlrelay lib => mysql client lib => tcp => mysql server I followed the instructions for the MySQL drop-in replacement and it works. I can connect to the backend MySQL server using both sqlrsh and mysql client application. It will work for most MySQL applications by using LD_PRELOAD with the compatibility layer library. The instructions recommend re-compiling php to support it. I would prefer not doing something so drastic. They also recommend setting the LD_PRELOAD for apachectl as a method for the apache/php stack. However, this does not work with lighttpd/php-cgi. I have wrapped php-cgi with a shell script that sets LD_PRELOAD before running the cgi script. LD_PRELOAD=/usr/lib/libmysql50sqlrelay-0.39.4.so.1 /usr/bin/php5-cgi $@ I can see LD_PRELOAD correctly set in phpinfo() but the cgi scripts all fail and are unable to connect to the database. According to the mysql client, the compatibility library should report itself as a 5.0.0 client but the phpinfo module reports itself as the actual 5.0.51a client library used. This means that the compatibility library was not used. Is there someone who has had some success doing something similar?

    Read the article

  • Apache / PHP Begins to Deny SQL Requests after about 2000

    - by Daniel Stern
    We have a web page on our server that we use to run administrative scripts. For example, we might run the script "unenrolStudents()" which runs 5,000 SQL SET commands one after another and sets 5000 student entries in an SQL database to unenrolled. However, we are finding that after running a few thousand queries (it is not totally consistent) we will be "locked out" by our server. SYMPTOMS OF LOCKING OUT: - unable to connect to server with winSCP - opening putty with that connection shows a blank screen (no login / pass) - clearing cookies / cache in chrome does NOT fix locking out - other computers in the office ALSO become locked out - locking out can be triggered with a high frequency of requests (10000 in 1 second) or by less over time (10000 in 500 seconds - this will still cause a lockout even though the frequency is much less) We believe this is a security feature of our own Apache. I know we are using Suhosin but I didn't configure it so I don't know. How can I disable this locking effect so that I can confidently run all my SQL requests and they will go through? Has anyone else dealt with this and found workarounds? Thanks DS

    Read the article

  • How to create RPM for 32-bit arch from a 64-bit arch server?

    - by Gnanam
    Our production server is running CentOS5 64-bit arch. Because there are no RPM available currently for SQLite latest version (v3.7.3), I created RPM using rpmbuild the very first time by following the instructions given here. I was able to successfully create RPM for 64-bit (x86_64) architecture. But am not able to create RPM for 32-bit (i386) architecture. It failed with the following errors: ... ... ... + ./configure --build=x86_64-redhat-linux-gnu --host=x86_64-redhat-linux-gnu --target=i386-redhat-linux-gnu --program-prefix= --prefix=/usr --exec-prefix=/usr --bindir=/usr/bin --sbindir=/usr/sbin --sysconfdir=/etc --datadir=/usr/share --includedir=/usr/include --libdir=/usr/lib64 --libexecdir=/usr/libexec --localstatedir=/var --sharedstatedir=/usr/com --mandir=/usr/share/man --infodir=/usr/share/info --enable-threadsafe checking for a BSD-compatible install... /usr/bin/install -c checking whether build environment is sane... yes checking for gawk... gawk checking whether make sets $(MAKE)... yes checking for style of include used by make... GNU checking for x86_64-redhat-linux-gnu-gcc... no checking for gcc... gcc checking for C compiler default output file name... configure: error: C compiler cannot create executables See `config.log' for more details. error: Bad exit status from /var/tmp/rpm-tmp.73141 (%build) RPM build errors: Bad exit status from /var/tmp/rpm-tmp.73141 (%build) This is the command I called: rpmbuild --target i386 -ba sqlite.spec My question is, how do I create RPM for 32-bit arch from a 64-bit arch server?

    Read the article

  • How to read an Excel file, get and set the information using POI

    - by user1399713
    I'm using Java to read a form that is in an Excel spreadsheet that the user fills in with information about geometric shape. Ex: Shape :_________ Color :_________ Area: _________ Perimeter:________ So far the code I have can I can read what I want in the form and print out the values of Shape, Color, Area, Perimeter. public class RangeSetter { /** * @param args * @throws IOException */ public static void main(String[] args) throws IOException { FileInputStream file = new FileInputStream(new File("test2.xls")); //C:\Users\Yo\Documents // Setup code String cname = "Shape"; HSSFWorkbook wb = new HSSFWorkbook(file); // retrieve workbook // Retrieve the named range // Will be something like "$C$10,$D$12:$D$14"; int namedCellIdx = wb.getNameIndex(cname); Name aNamedCell = wb.getNameAt(namedCellIdx); // Retrieve the cell at the named range and test its contents // Will get back one AreaReference for C10, and // another for D12 to D14 AreaReference[] arefs = AreaReference.generateContiguous(aNamedCell.getRefersToFormula()); for (int i=0; i<arefs.length; i++) { // Only get the corners of the Area // (use arefs[i].getAllReferencedCells() to get all cells) CellReference[] crefs = arefs[i].getAllReferencedCells(); for (int j=0; j<crefs.length; j++) { // Check it turns into real stuff Sheet s = wb.getSheet(crefs[j].getSheetName()); Row r = s.getRow(crefs[j].getRow()); Cell c = r.getCell(crefs[j].getCol()); if (c!= null ){ switch(c.getCellType()){ case Cell.CELL_TYPE_STRING: System.out.println(c.getStringCellValue()); } } } } What I want to do is to create a method that gets the that information and another that sets it. So far I can only print to the console

    Read the article

  • Blu-ray BD-R: Would you physically store it in a CaseLogic Wallet pocket?

    - by Rob
    I keep several backup copies of my material and files. For my DVDs, one set of copies is kept in a CaseLogic wallet folder pack, so that I can easily move this around when visiting friends, family or for business. This is highly convenient. The other sets are kept in their jewel cases in hard plastic see thru storage boxes. Although CaseLogic wallet material is designed to be abrasion free, their caveat is that external dust will be the cause of any blemishes. If hard dust gets in these pockets, which is inevitable, this will occasionally cause light hair like scratches on the disc surface as the discs are removed and returned for access to their contents. This is of no consequence as the laser and error correction can more than cope with this. I'm aware that the blu-ray spec requires anti-scratch in disc surfaces but was wondering that, given the smaller pits, would dust and light scratches from wallet storage cause more problems with blu-rays than they would with DVDs? I'm using Blu-ray BD-R and BD-R DL write once media.

    Read the article

  • MySQL not releasing temp file descriptors

    - by Wakaru44
    Since a few days ago, we’ve been experiencing some serious problems with our MySQL installation: MySQL keeps opening temporal files (normal behaviour) but these files are never released. The consequence is that, eventually, the disk space is exhausted and we have to restart the service and clean up /tmp manually. Using lsof, we see something like this: mysqld 16866 mysql 5u REG 8,3 0 692 /tmp/ibyWJylQ (deleted) mysqld 16866 mysql 6u REG 8,3 0 707 /tmp/ibf5adsT (deleted) mysqld 16866 mysql 7u REG 8,3 0 728 /tmp/ibGjPRyW (deleted) mysqld 16866 mysql 8u REG 8,3 0 5678 /tmp/ibMQDLMZ (deleted) mysqld 16866 mysql 13u REG 8,3 0 5679 /tmp/ibQAnM42 (deleted) Maybe it's not related, but when we shutdown the server, the files are finally freed, and we can see the following warnings in the MySQL log: 121029 7:44:27 [Warning] /usr/local/mysql/bin/mysqld: Forcing close of thread 1333 user: 'xxx' 121029 7:44:27 [Warning] /usr/local/mysql/bin/mysqld: Forcing close of thread 1156 user: 'yyy' 121029 7:44:27 [Warning] /usr/local/mysql/bin/mysqld: Forcing close of thread 1151 user: 'zzz' where 'xxx', 'yyy' and 'zzz' are distinct mysql users (and the only 3 users with active connections to the database). We have a few theories: There is a problem in the OS, that keeps file handlers open. Could it be possible that the OS "delete" operation blocks the threads until shutdown? This may explain the warning at shutdown and the fact that files are finally deleted when the process dies. Until now, data sets were so small that temp files were relatively small and there was enough time to release the file handles without exhausting disk space. We are using Mysql 5.5 on a RHEL 6.2 with the default kernel.

    Read the article

  • Ubuntu Cannot change permissions on files I own and have RW to.

    - by madmaze
    Hello there, I have a harddrive full of backups which for me is mounted at /media/chronus_ I have been trying to give another user rw permission to this drive. The problem is that I cannot change any permissions on this drive, even if i make a new file it puts sets everything to -rw------- here is an excerpt of what i have tried: madmaze@the-gibson:~$ touch testfile madmaze@the-gibson:~$ ls -l testfile -rw-r--r-- 1 madmaze madmaze 0 2011-01-16 20:11 testfile madmaze@the-gibson:~$ chmod 777 testfile madmaze@the-gibson:~$ ls -l testfile -rwxrwxrwx 1 madmaze madmaze 0 2011-01-16 20:11 testfile madmaze@the-gibson:~$ cd /media/chronos_/Pix/ madmaze@the-gibson:/media/chronos_/Pix$ ls -l total 4100 -rw------- 1 madmaze madmaze 28226 2011-01-16 20:18 avp.jpg -rw------- 1 madmaze madmaze 5764 2011-01-16 20:18 avpsmall.jpg -rw------- 1 madmaze madmaze 98414 2011-01-16 20:18 john.jpg -rw------- 1 madmaze madmaze 98785 2011-01-16 20:18 lisa.jpg -rw------- 1 madmaze madmaze 3954281 2011-01-16 20:18 peter.jpg madmaze@the-gibson:/media/chronos_/Pix$ chmod 777 *.jpg madmaze@the-gibson:/media/chronos_/Pix$ ls -l total 4100 -rw------- 1 madmaze madmaze 28226 2011-01-16 20:18 avp.jpg -rw------- 1 madmaze madmaze 5764 2011-01-16 20:18 avpsmall.jpg -rw------- 1 madmaze madmaze 98414 2011-01-16 20:18 john.jpg -rw------- 1 madmaze madmaze 98785 2011-01-16 20:18 lisa.jpg -rw------- 1 madmaze madmaze 3954281 2011-01-16 20:18 peter.jpg madmaze@the-gibson:/media/chronos_/Pix$ sudo chmod 777 *.jpg madmaze@the-gibson:/media/chronos_/Pix$ ls -l total 4100 -rw------- 1 madmaze madmaze 28226 2011-01-16 20:18 avp.jpg -rw------- 1 madmaze madmaze 5764 2011-01-16 20:18 avpsmall.jpg -rw------- 1 madmaze madmaze 98414 2011-01-16 20:18 john.jpg -rw------- 1 madmaze madmaze 98785 2011-01-16 20:18 lisa.jpg -rw------- 1 madmaze madmaze 3954281 2011-01-16 20:18 peter.jpg madmaze@the-gibson:/media/chronos_/Pix$ touch testfile madmaze@the-gibson:/media/chronos_/Pix$ ls -l testfile -rw------- 1 madmaze madmaze 0 2011-01-16 20:25 testfile madmaze@the-gibson:/media/chronos_/Pix$ chmod 777 testfile madmaze@the-gibson:/media/chronos_/Pix$ ls -l testfile -rw------- 1 madmaze madmaze 0 2011-01-16 20:25 testfile madmaze@the-gibson:/media/chronos_/Pix$ Any Ideas what I could be doing wrongly?

    Read the article

  • Is there a way to avoid Wacom Control Panel to stop showing in certain cases ?

    - by S.gfx
    This is the problem: Suddenly, you double click on desktop wacom tablet settings icon, and it wont show the dialog. It appears to be loaded as it's shown down in the windows taskbar. I suspect is caused by change of resolution or some setting, maybe suddenly it sets the origin of the panel dialog at some 3000 thosand pixels to the right or something. I have digged that wacom_tablet.dat file to see if I fix it changing some value there, but looks like a log, a history, more than a ini for settings... And anyway does not solve it. My solution is having always a very complete settings file done and backed up to restore (with wacom utility for this, which in previous driver versions did not exist) when this happens, but is counter productive: You change the settings even per each project(and software) needs. I have seen it happenning with Cintiq 12", intuos4 A6, Graphires, Intuos 1. Is just me, doing something weird every time? I doubt it, is normal use, I am amazed that seems no one else had this prob(or nobody asked), happens often with typical use. Maybe is because am setting a shortcut in the desktop? Weird as it works perfect till some random moment... (Have digged Wacom's forums and FAQs, then here, but nothing related to it... Neither in "related questions".) The thing happens in Win XP, 7, etc. Done so during years in my experience, and several times at work, which is worse.

    Read the article

  • How can I download a copy of an S3 public data set?

    - by tripleee
    i was naively assuming I could do something like s3cmd sync s3://snap-d203feb5 /var/tmp/copy but I seem to have the wrong idea of how to go about this. I cannot even get a simple thing to work; vnix$ s3cmd ls s3://snap-d203feb5 Bucket 'snap-d203feb5': ERROR: Bucket 'snap-d203feb5' does not exist I guess the identifier I have is not for a "bucket" but for a "public data set". How do I go from one to the other? Do I have to start up an EC2 instance and create a bucket for this? How? The instructions at http://docs.amazonwebservices.com/AWSEC2/latest/UserGuide/using-public-data-sets.html seem to assume I want to use the data in an EC2 instance, but in this case, I'd just like to browse a bit, at least for a start. By the by, copy/pasting the "US Snapshot ID" causes a nasty traceback from Python; they publish the ID with a weird Unicode (I presume) dash which cannot directly be copy/pasted. Is there a mistake when I copy it? And what's the significance of "US" in there? Can't I use the data outside North America??

    Read the article

  • Change font size for "Default Paragraph Font" in Word

    - by Richard Gadsden
    I have a document where the built-in style "Default Paragraph Font" has been set to a particular size. It shouldn't have a size - it should be inheriting from the paragraph style (that's the whole point of the style). If I go through the user interface, I can't modify this style (the modify button / dropdown is greyed out) While I can work around this in most places, it creates problems for the Table of Contents in particular, as that is forced to be in this style and it overrides the font size from the styles like TOC 1 (etc). I can set the font size through VBA - ActiveDocument.Styles("Default Paragraph Font").Font.size = 10 sets it to ten point, but I can't work out how to reset it back to inherit. At the moment, my table of contents is set to be all in the same size, but really TOC 1 should be bigger than TOC 2. Does anyone have any suggestions for how to fix this? One approach is to use the organizer to copy over the style from a working document, but ideally I'd like a way to resolve the problem without doing that - especially as that's not an easy approach to automate.

    Read the article

  • Netgear GS724Tv3 and link aggregation Mac OS X Server 10.6.8

    - by Manca Weeks
    I need to link aggregate 2 sets of ports on the Netgear GS724T with my Apple server tower (latest generation). I have 2 built in ports and 2 ports on a PCIe ethernet card. It is not obvious to me how to properly configure the Netgear end. I have access to the Netgear box through its web interface, just don't know how to properly set the settings. I tried going to Netgear for help, but they said my software support has expired. I bought this unit on their recommendation - they say it is compatible with 802.3ad protocol. I cannot locate any references to this protocol in the manual and I noticed some people in formus say that this device is actually not compatible with 802.3ad and that Netgear is misleading potential customers by saying it is. Any help will be appreciated. Thanks, M My own answer - posted as edit because of restrictions on my user: OK folks, turns out one must use a Windows machine on this one or nothing makes sense. I was unable to get much farther than viewing the default inactive LAGs because in Firefox and Safari on Mac things don't make much sense - i.e. the Apply buttons (supposedly JavaScript) don't work. You can view the configurations, but none of the modifications you make stick. Then, in Switching - LAGs, choose the ports to include and make sure you switch the LAG type from Static to LACP and all is well. Haven't tested the performance of the config yet, but both sides appear to be happy with the configuration. Apple server says link active and so does the Netgear. Will report if any other discoveries. Thanks for all who read and to user84104 for responding. M

    Read the article

  • Appears to be "randomly" switching between the acl matched backend and the default backend

    - by Xoor
    I have HAProxy acting as a proxy in front of: An NGinx instance An in-house load balancer in front of multiple dynamic services exposed with socket.io (websockets) My problem is that from time to time my connections are proxied correctly to my socket.io cluster, and then randomly it fallsback to routing to NGinx which obviously is annoying and meaningless since NGinx isn't mean't to handle the request. This happens when requesting for URLs of the format : http://mydomain.com/backends/* There's an ACL in the HAProxy config to match the '/backends/*' path. Here's a simplified version of my HAProxy config (removed extra unrelated entries and changed names): global daemon maxconn 4096 user haproxy group haproxy nbproc 4 defaults mode http timeout server 86400000 timeout connect 5000 log global #this frontend interface receives the incoming http requests frontend http-in mode http #process all requests made on port 80 bind *:80 #set a large timeout for websockets timeout client 86400000 # Default Backend default_backend www_backend # Loadfire (socket cluster) acl is_loadfire_backends path_beg /backends use_backend loadfire_backend if is_loadfire_backends # NGinx backend backend www_backend server www_nginx localhost:12346 maxconn 1024 # Loadfire backend backend loadfire_backend option forwardfor # This sets X-Forwarded-For option httpclose server loadfire localhost:7101 maxconn 2048 It's really quite confusing for me why the behaviour appears to be "random", since being hard to reproduce it's hard to debug. I appreciate any insight on this.

    Read the article

  • Diagnosing a BSOD involving USB

    - by David Ebbo
    [Running Win7 Ultimate 64 bit] My new HP Pavilion Elite HPE-450t has been plagued by BSDO crashes since I got it about 5 weeks ago. The crashes are somewhat rare, sometimes not occurring for 3 or 4 days. I have spent a lot of time trying to isolate the device that could be at fault, but I have seen crashes with only the keyboard and mouse plugged in (as USB devices), and I tried two sets of keyboard/mouse, so I'm running out of ideas. :( The WhoCrashed tool gave this info about my latest BSOD: crash dump file: C:\Windows\Minidump\121310-11887-01.dmp This was probably caused by the following module: usbport.sys (USBPORT+0x2DE4E) Bugcheck code: 0xFE (0x5, 0xFFFFFA8008F571A0, 0x80863B34, 0xFFFFFA80092F2510) Error: BUGCODE_USB_DRIVER file path: C:\Windows\system32\drivers\usbport.sys product: Microsoft® Windows® Operating System company: Microsoft Corporation description: USB 1.1 & 2.0 Port Driver Bug check description: This indicates that an error has occurred in a Universal Serial Bus (USB) driver. The crash took place in a standard Microsoft module. Your system configuration may be incorrect. Possibly this problem is caused by another driver on your system which cannot be identified at this time. I looked at http://msdn.microsoft.com/en-us/library/ff560407(VS.85).aspx, and for Parameter1 = 0x5, it says "A hardware failure has occurred due to a bad physical address found in a hardware data structure. This is not due to a driver bug". Should I conclude that it's a hardware issue in the machine itself, rather than a bad USB driver or USB device? Here is the MiniDump, in case someone can get more info out of it: http://ewt52q.blu.livefilestore.com/y1peS4Ce8nSK1SXghzMDoxDWXlaEu-EKCJsv25y8y5DXXIUzZ9U0_tYgFJXd939fykwa0zRmx98IW0PYG18GioqKAuARYjtspSA/121310-11887-01.dmp?download&psid=2

    Read the article

  • Windows Server 2008 backup VHD's - is it possible to mount/open in Windows 7?

    - by Simon
    Hi All, Is it possible to mount the VHD files created by the Windows Server 2008 backup utility onto a Windows 7 (release) client? Following an array failure I was very worried that there was a problem with both the backup sets on different USB drives as attaching the VHD to a Win 7 box did not show the expected structure (instead they behaved like unformatted disk space). Subsequently, I've attached the backup drive to a 2008r2 machine that I'd intended to be the replacement and the backup set can be browsed without issue (seemingly). When the new disks arrive I'll go through the recovery process and see where we are, but it looks promising so far. Is it simply the case that you can't take server created VHD's and mount them on desktop machines? (Rather than hyper-ventilating at the thought of years of lost photos and email, I'm now just mildly curious) Edit:One thing that has confused things is that the backup utility on Win7 is more restrictive about restoring from external devices than the equivilent on 2008r2. With r2, I can restore files 'from another server' and browse to external storage. Win7 only allows the back to be located on a network share. Once my box of new disks arrive and I've got something to restore onto, I'll move the smaller of the backup VHDs onto network storage reachable by Win7 and see if the VHD is readable. I haven't read up on the VHD process used by the backup app - I'm assuming it's a base VHD and differencing files used for incremental backups and that the restore app understands this. Finally: In retrospect the question should have been, 'can I restore a 2008r2 backup set via a Win 7 client' Thanks

    Read the article

  • How do hdparm's -S and -B options interact?

    - by user697683
    These two options seem confusing. For example: according to the man page -B 254 "does not permit spin-down". However, testing with -B 254 -S 1 the drive does spin down after 5 seconds. -B Query/set Advanced Power Management feature, if the drive supports it. A low value means aggressive power management and a high value means better performance. Possible settings range from values 1 through 127 (which permit spin-down), and values 128 through 254 (which do not permit spin-down). The highest degree of power management is attained with a setting of 1, and the highest I/O performance with a setting of 254. A value of 255 tells hdparm to disable Advanced Power Management altogether on the drive (not all drives support disabling it, but most do). -S Put the drive into idle (low-power) mode, and also set the standby (spindown) timeout for the drive. This timeout value is used by the drive to determine how long to wait (with no disk activity) before turning off the spindle motor to save power. Under such circumstances, the drive may take as long as 30 seconds to respond to a subsequent disk access, though most drives are much quicker. The encoding of the timeout value is somewhat peculiar. A value of zero means "timeouts are disabled": the device will not automatically enter standby mode. Values from 1 to 240 specify multiples of 5 seconds, yielding timeouts from 5 seconds to 20 minutes. Values from 241 to 251 specify from 1 to 11 units of 30 minutes, yielding timeouts from 30 minutes to 5.5 hours. A value of 252 signifies a timeout of 21 minutes. A value of 253 sets a vendor-defined timeout period between 8 and 12 hours, and the value 254 is reserved. 255 is interpreted as 21 minutes plus 15 seconds. Note that some older drives may have very different interpretations of these values.

    Read the article

  • ubuntu 9.10 installer doesn't recognize the hard drive

    - by dan
    I downloaded Ubuntu 9.10 x86_64 and am trying to install it on a fairly modern system with a Gigabyte GA-MA770-UD3 motherboard. Ubuntu 9.04 installed fine and still will when I stick that disc in, but 9.10 doesn't see my hard drive (western digital 250GB). If I boot from the disc, I can install gparted and it does recognize the drive, but when I try to start the install process from the live disc, Ubuntu again doesn't recognize the hard drive. I checked /var/log/messages and see this: Nov 12 17:28:08 ubuntu activate-dmraid: Serial ATA RAID disk(s) detected. If this was bad, boot with 'nodmraid'. Nov 12 17:28:08 ubuntu activate-dmraid: Enabling dmraid support Nov 12 17:28:08 ubuntu activate-dmraid: ERROR: either the required RAID set not found or more options required. Nov 12 17:28:08 ubuntu activate-dmraid: ERROR: either the required RAID set not found or more options required. Nov 12 17:28:08 ubuntu activate-dmraid: ERROR: either the required RAID set not found or more options required. Nov 12 17:28:08 ubuntu activate-dmraid: no raid sets and with names: "nvidia_ciiajheb-0" Nov 12 17:28:08 ubuntu activate-dmraid: ERROR: either the required RAID set not found or more options required. I checked my BIOS, SATA is enabled and is set to IDE mode, so there shouldn't be software RAID, but nonetheless, I added nodmraid to the boot line and tried again. It still doesn't recognize the drive. I checked /var/log/messages again and now see this: Nov 12 17:49:38 ubuntu activate-dmraid: Serial ATA RAID disk(s) detected. If this was boad, boot with 'nodmraid'. Nov 12 17:49:38 ubuntu activate-dmraid: Enabling dmraid support Nov 12 17:49:38 ubuntu activate-dmraid: WARNING: dmraid disabled by boot option Nov 12 17:49:38 ubuntu activate-dmraid: WARNING: dmraid disabled by boot option Any ideas on things to try? I've tried all of the various BIOS settings for SATA. IDE,RAID, etc. Nothing seems to work.

    Read the article

  • What can cause Powershell execution policy not to be taken into account?

    - by Stephane
    We have in our infrastructure a number of powershell scripts used for various tasks ranging from user login to support technician simulating a user context. These scripts are centralized on our file server (through DFS) for easier management. Some of them are run at logon, some are run through published Citrix applications. We have applied a policy for the whole domain and all users that sets the Powershell execution policy to "unrestricted" so that the scripts can run from the file server. This works perfectly fine for logon script (at least, so far) but for scripts that are run later (usually through a published application but the same applies when using terminal services and a full desktop), the results are inconsistent: some users can run the script fine, some are always prompted in the powershell console for letting the scripts run. I cannot find anything that could cause this behavior and it's really inconsistent: if I start powershell manually and runs get-executionpolicy, I am told that the current policy is unrestricted. Yet, if from the same session I try to run a script through a program that calls powershell <script file name> <parameters> I get prompted before the script can run. What could cause such behavior ?

    Read the article

< Previous Page | 80 81 82 83 84 85 86 87 88 89 90 91  | Next Page >