Search Results

Search found 61490 results on 2460 pages for 'windows mobile 5 0'.

Page 842/2460 | < Previous Page | 838 839 840 841 842 843 844 845 846 847 848 849  | Next Page >

  • MSBuild: TlbImp error since upgrading to VS 2010

    - by floele
    Hi, since upgrading my project to VS2010, including the use of MSBuild v4 instead of 3.5 (and not making any other changes), I get the following build error and have no clue how to fix it (log from CC.NET): <target name="ResolveComReferences" success="false"> <message level="high"><![CDATA[C:\Programme\Microsoft SDKs\Windows\v7.0A\bin\TlbImp.exe c:\Assemblies\NMSDVDXU.dll /namespace:NMSDVDXLib /machine:X64 /out:obj\x64\Release\Interop.NMSDVDXLib.dll /sysarray /transform:DispRet /reference:c:\Assemblies\Bass.Net.dll /reference:c:\Assemblies\LogicNP.FileView.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\mscorlib.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Data.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Design.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Drawing.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Management.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Windows.Forms.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Xml.dll /reference:C:\WINDOWS\assembly\GAC\stdole\7.0.3300.0__b03f5f7f11d50a3a\stdole.dll ]]></message> <error code="TI0000" file="TlbImp"><![CDATA[A single valid machine type compatible with the input type library must be specified.]]></error> <warning code="MSB3283" file="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets" line="1558" column="9"><![CDATA[Die Wrapperassembly für die Typbibliothek "NMSDVDXLib" wurde nicht gefunden.]]></warning> <message level="high"><![CDATA[C:\Programme\Microsoft SDKs\Windows\v7.0A\bin\TlbImp.exe c:\Assemblies\StarBurnX12.dll /namespace:RocketDivision.StarBurnX /machine:X64 /out:obj\x64\Release\Interop.RocketDivision.StarBurnX.dll /sysarray /transform:DispRet /reference:c:\Assemblies\Bass.Net.dll /reference:c:\Assemblies\LogicNP.FileView.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\mscorlib.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Data.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Design.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Drawing.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Management.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Windows.Forms.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Xml.dll /reference:C:\WINDOWS\assembly\GAC\stdole\7.0.3300.0__b03f5f7f11d50a3a\stdole.dll ]]></message> <error code="TI0000" file="TlbImp"><![CDATA[A single valid machine type compatible with the input type library must be specified.]]></error> <warning code="MSB3283" file="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets" line="1558" column="9"><![CDATA[Die Wrapperassembly für die Typbibliothek "RocketDivision.StarBurnX" wurde nicht gefunden.]]></warning> </target> Problem: A single valid machine type compatible with the input type library must be specified. It only applies to the x64 build of my project, x86 still works fine. Apparently, it tries to build a x64 interop assembly from the x86 DLL located in "C:\Assemblies". When executing the TlbImp command with the x64 DLL which is located in a different directory, it works fine. However, I don't know how I can configure my project to use different COM references for the x86 and x64 build. The OS on which the project is being compiled is WinXP x86. Building worked fine when using VS2005 + MSBuild 3.5 Any help would be highly appreciated. I tried building the upgraded project with MSBuild v3.5, but that doesn't work either. It complains about unknown NoWarn codes (probably new in 4.0).

    Read the article

  • How to get around batch file processing limit

    - by Patrick Cuff
    I have a Windows batch file that processes all the files in a given directory. I have 206,783 files I need to process: for %%f in (*.xml) do call :PROCESS %%f goto :STOP :PROCESS :: do something with the file program.exe %1 > %1.new set /a COUNTER=%COUNTER%+1 goto :EOF :STOP @echo %COUNTER% files processed When I run the batch file, the following output is written: 65535 files processed As part of the processing, an output file is created for each file procesed, with a .new extension. When I do a dir *.new it reports 65,535 files exist. So, it appears my command environment has a hard limit on the number of files it can recognize, and that limit is 64K - 1. Is there a way to extend the command environment to manage more than 64K - 1 files? If not, would a VBScript or JavaScript be able to process all 206,783 files? I'm running on Windows 2003 server, Enterprise Edition, 32-bit. UPDATE It looks like the root cause of my issue was with the built-in Windows "extract" command for ZIP files. The files I have to process were copied from another system via a ZIP file. My server doesn't have a ZIP utility installed, just the native Windows commands. I right-clicked on the ZIP file, and did an "Extract all...", which apparently just extracted the first 65,535 files. I downloaded and installed 7-zip onto my server, unzipped all the files, and my batch script worked as intended.

    Read the article

  • eventmachine and external scripts via backticks

    - by Maciek
    I have a small HTTP server script I've written using eventmachine which needs to call external scripts/commands and does so via backticks (``). When serving up requests which don't run backticked code, everything is fine, however, as soon as my EM code executes any backticked external script, it stops serving requests and stops executing in general. I noticed eventmachine seems to be sensitive to sub-processes and/or threads, and appears to have the popen method for this purpose, but EM's source warns that this method doesn't work under Windows. Many of the machines running this script are running Windows, so I can't use popen. Am I out of luck here? Is there a safe way to run an external command from an eventmachine script under Windows? Is there any way I could fire off some commands to be run externally without blocking EM's execution? edit: the culprit that seems to be screwing up EM the most is my usage of the Windows start command, as in: start java myclass. The reason I'm using start is because I want those external scripts to start running and keep running after the EM request is served

    Read the article

  • Malware - Technical anlaysis

    - by nullptr
    Note: Please do not mod down or close. Im not a stupid PC user asking to fix my pc problem. I am intrigued and am having a deep technical look at whats going on. I have come across a Windows XP machine that is sending unwanted p2p traffic. I have done a 'netstat -b' command and explorer.exe is sending out the traffic. When I kill this process the traffic stops and obviously Windows Explorer dies. Here is the header of the stream from the Wireshark dump (x.x.x.x) is the machines IP. GNUTELLA CONNECT/0.6 Listen-IP: x.x.x.x:8059 Remote-IP: 76.164.224.103 User-Agent: LimeWire/5.3.6 X-Requeries: false X-Ultrapeer: True X-Degree: 32 X-Query-Routing: 0.1 X-Ultrapeer-Query-Routing: 0.1 X-Max-TTL: 3 X-Dynamic-Querying: 0.1 X-Locale-Pref: en GGEP: 0.5 Bye-Packet: 0.1 GNUTELLA/0.6 200 OK Pong-Caching: 0.1 X-Ultrapeer-Needed: false Accept-Encoding: deflate X-Requeries: false X-Locale-Pref: en X-Guess: 0.1 X-Max-TTL: 3 Vendor-Message: 0.2 X-Ultrapeer-Query-Routing: 0.1 X-Query-Routing: 0.1 Listen-IP: 76.164.224.103:15649 X-Ext-Probes: 0.1 Remote-IP: x.x.x.x GGEP: 0.5 X-Dynamic-Querying: 0.1 X-Degree: 32 User-Agent: LimeWire/4.18.7 X-Ultrapeer: True X-Try-Ultrapeers: 121.54.32.36:3279,173.19.233.80:3714,65.182.97.15:5807,115.147.231.81:9751,72.134.30.181:15810,71.59.97.180:24295,74.76.84.250:25497,96.234.62.221:32344,69.44.246.38:42254,98.199.75.23:51230 GNUTELLA/0.6 200 OK So it seems that the malware has hooked into explorer.exe and hidden its self quite well as a Norton Scan doesn't pick anything up. I have looked in Windows firewall and it shouldn't be letting this traffic through. I have had a look into the messages explorer.exe is sending in Spy++ and the only related ones I can see are socket connections etc... My question is what can I do to look into this deeper? What does malware achieve by sending p2p traffic? I know to fix the problem the easiest way is to reinstall Windows but I want to get to the bottom of it first, just out of interest.

    Read the article

  • Problem detecting installed application on Win Svr 2003 x64

    - by PD
    I have an x86 Windows application that consists of a couple of services and a client ui. Due to various issues with persuading the various MSIs to upgrade properly, the installation process is now governed by a wizard-style program that detects what is currently installed and handles upgrades by storing the user's current settings, uninstalling the existing software and installing the new version(s). The basic process is: Look in HKLM\Software\Classes\Installer\Products Loop through the GUID keys therein looking for ProductName="(my app name)" If not found, repeat starting from HKCU\Software\Microsoft\Installer\Products instead If found, offer the user an upgrade (as described earlier) else a clean install (i.e. user is asked various questions by the wizard) Now, this works just fine on pretty much any Windows platform you care to mention, from XP up. It fails only on Windows Server 2003 x64, in that an existing installation is not detected by the wizard - despite the exact same registry keys being present as are on any other platform I test on. It's fine on: XP x32 Vista x32, x64 Server 2003 x86 Server 2008 x86, x64 Server 2008 R2 x64 Windows 7 x86, x64 It's only Server 2003 x64 that seems to exhibit this issue.

    Read the article

  • Where should I store shared resources between LocalSystem and regular user with UAC?

    - by rwired
    My application consists of two parts: A Windows Service running under the LocalSystem account and a client process running under the currently logged in regular user. I need to deploy the application across Windows versions from XP up to Win7. The client will retrieve files from the web and collect user data from the user. The service will construct files and data of it's own which the client needs to read. I'm trying to figure out the best place (registry or filesystem, or mix) to store all this. One file the client or service needs to be able to retrieve from the net is an update_patch executable which needs to run whenever an upgrade is available. I need to be sure the initial installer SETUP.EXE, and also the update_patch can figure out this ideal location and set a RegKey to be read later by both client and server telling them the magic location (The SETUP.EXE will run with elevated privileges since it needs to install the service) On my Win7 test system the service %APPDATA% points to: C:\Windows\system32\config\systemprofile\AppData\Roaming and the %APPDATA% of the client points to: C:\Users\(username)\AppData\Roaming Interestingly Google Chrome stores everything (App and Data) in C:\Users\(username)\AppData\Local\Google\Chrome Chrome runs pretty much in exactly the way I want my suite to run (able to silently update itself in the background) What I'm trying to avoid is nasty popups warning the user that the app wants to modify the system, and I want to avoid problems when VirtualStore doesn't exist because the user is running XP/2000/2003 or has UAC turned off. My target audience are non-tech-savvy general Windows users.

    Read the article

  • How to optimize paging for large in memory database

    - by snakefoot
    I have an application where the entire database is implemented in memory using a stl-map for each table in the database. Each item in the stl-map is a complex object with references to other items in the other stl-maps. The application works with a large amount of data, so it uses more than 500 MByte RAM. Clients are able to contact the application and get a filtered version of the entire database. This is done by running through the entire database, and finding items relevant for the client. When the application have been running for an hour or so, then Windows 2003 SP2 starts to page out parts of the RAM for the application (Eventhough there is 16 GByte RAM on the machine). After the application have been partly paged out then a client logon takes a long time (10 mins) because it now generates a page fault for each pointer lookup in the stl-map. I can see it is possible to tell Windows to lock memory in RAM, but this is generally only recommended for device drivers, and only for "small" amounts of memory. I guess a poor mans solution could be to loop through the entire memory database, and thus tell Windows we are still interested in keeping the datamodel in RAM. I guess another poor mans solution could be to disable the pagefile completely on Windows. I guess the expensive solution would be a SQL database, and then rewrite the entire application to use a database layer. Then hopefully the database system will have implemented means to for fast access. Are there other more elegant solutions ?

    Read the article

  • Sharing a global/static variable between a process and DLL

    - by minjang
    I'd like to share a static/global variable only between a process and a dll that is invoked by the process. The exe and dll are in the same memory address space. I don't want the variable to be shared among other processes. Elaboration of the problem: Say that there is a static/global variable x in a.cpp. Both the exe foo.exe and the dll bar.dll have a.cpp, so the variable x is in both images. Now, foo.exe dynamically loads (or statically) bar.dll. Then, the problem is whether the variable x is shared by the exe and dll, or not. In Windows, these two guys never share the x: the exe and dll will have a separate copy of x. However, in Linux, the exe and dll do share the variable x. Unfortunately, I want the behavior of Linux. I first considered using pragma data_seg on Windows. However, even if I correctly setup the shared data segment, foo.exe and bar.dll never shares the x. Recall that bar.dll is loaded into the address space of foo.exe. However, if I run another instance of foo.exe, then x is shared. But, I don't want x to be shared by different processes. So, using data_seg was failed. I may it use a memory-mapped file by making an unique name between exe and dll, which I'm trying now. Two questions: Why the behavior of Linux and Windows is different? Can anyone explain more about this? What would be most easiest way to solve this problem on Windows?

    Read the article

  • How to avoid mouse move on Touch

    - by VirtualBlackFox
    I have a WPF application that is capable of being used both with a mouse and using Touch. I disable all windows "enhancements" to just have touch events : Stylus.IsPressAndHoldEnabled="False" Stylus.IsTapFeedbackEnabled="False" Stylus.IsTouchFeedbackEnabled="False" Stylus.IsFlicksEnabled="False" The result is that a click behave like I want except on two points : The small "touch" cursor (little white star) appears where clicked an when dragging. Completely useless as the user finger is already at this location no feedback is required (Except my element potentially changing color if actionable). Elements stay in the "Hover" state after the movement / Click ends. Both are the consequences of the fact that while windows transmit correctly touch events, he still move the mouse to the last main-touch-event. I don't want windows to move the mouse at all when I use touch inside my application. Is there a way to completely avoid that? Notes: Handling touch events change nothing to this. Using SetCursorPos to move the mouse away make the cursor blink and isn't really user-friendly. Disabling the touch panel to act as an input device completely disable all events (And I also prefer an application-local solution, not system wide). I don't care if the solution involve COM/PInvoke or is provided in C/C++ i'll translate. If it is necessary to patch/hook some windows dlls so be it, the software will run on a dedicated device anyway. I'm investigating the surface SDK but I doubt that it'll show any solution. As a surface is a pure-touch device there is no risk of bad interaction with the mouse.

    Read the article

  • Why "Content-Length: 0" in POST requests?

    - by stesch
    A customer sometimes sends POST requests with Content-Length: 0 when submitting a form (10 to over 40 fields). We tested it with different browsers and from different locations but couldn't reproduce the error. The customer is using Internet Explorer 7 and a proxy. We asked them to let their system administrator see into the problem from their side. Running some tests without the proxy, etc.. In the meantime (half a year later and still no answer) I'm curious if somebody else knows of similar problems with a Content-Length: 0 request. Maybe from inside some Windows network with a special proxy for big companies. Is there a known problem with Internet Explorer 7? With a proxy system? The Windows network itself? Google only showed something in the context of NTLM (and such) authentication, but we aren't using this in the web application. Maybe it's in the way the proxy operates in the customer's network with Windows logins? (I'm no Windows expert. Just guessing.) I have no further information about the infrastructure.

    Read the article

  • Identity alternative for SQL Azure Federation : are Azure Queues or Service Bus Queues a good choice?

    - by JYL
    As many of developers, I'm looking for a way to integrate my existing app to SQL Azure Federations, and replacing the Identity columns (the primary keys of my tables) is a big problem. For many reasons, I do NOT want use GUID for my primary keys (please don't open the debate about the GUID or not, it's not my question : i just don't want a GUID, period). So I need to build a key provider to replace the "identity" feature of a standard SQL database. I'm using Entity Framework, so i can easily find one place to set the Id value just before the insert (by overriding the SaveChanges method of my ObjectContext class). I just need to find a "not too complicated" implementation for getting the current Id, which is "farm-ready". I've read this SO post : "ID Generation for Sharded Database (Azure Federated Database)" and "Synchronizing Multiple Nodes in Windows Azure from MSDN Magazine", but this solution sounds a bit complicated for me. I'm thinking about creating (automatically) one azure queue for each SQL table, which contain a pre-loaded list of consecutive integer. When I want an Id value, I just have to get a message from the queue (which becomes invisible and is deleted on the way), which give me the current available Id. About the choice between "Windows Azure Queues" and "Windows Azure Service Bus Queues", I prefere "Windows Azure Queues", due to the "high" latency of Service Bus Queues. I don't think that the lack of "ordering garantee" of Azure Queues is a problem. What do you think about that idea of using Azure Queues to provide Id values ? Do you see any argument to give up that idea ? Do you have a better idea, or even a good practice, to provider integer ids in SQL Azure Federation databases ? Thanks.

    Read the article

  • How to get call notification using mobile substrate on iphone?

    - by prathumca
    Hi all, I want to use mobile substrate to "hook" some code into IPhone's "MobileCal" app so that the injected code will send a notification to my app MobileCal gets a call notification. But I'm out of luck and no clue which method need to be replaced by my "hooking" method in the "MobileCal" app. For example, the "MobileLog" and "iRealSMS" has the same functionality and they used mobile substrate to hook their code into "MobileCal" app. If any one has any clue, I would definitely appreciate them.

    Read the article

  • How to give an alert in the mobile browser?

    - by MadhuBala
    When we try to open an attachment file from the mail, the desktop browser asks to save / open the file. As like that I need to do in the android mobile browser. How it's possible to ask a question in the mobile browser at the time of open an attachment file (*.ics)? Can anyone help me to develop an application for this ???

    Read the article

  • Ask How-To Geek: Learning the Office Ribbon, Booting to USB with an Old BIOS, and Snapping Windows

    - by Jason Fitzpatrick
    You’ve got questions and we’ve got answers. Today we highlight how to master the new Office interface, USB boot a computer with outdated BIOS, and snap windows to preset locations. Learning the New Office Ribbon Dear How-To Geek, I feel silly asking this (in light of how long the new Office interface has been out) but my company finally got around to upgrading from Windows XP and Office 2000 so the new interface it totally new to me. Can you recommend any resources for quickly learning the Office ribbon and the new changes? I feel completely lost after two decades of the old Office interface. Help! Sincerely, Where the Hell is Everything? Dear Where the Hell, We think most people were with you at some point in the last few years. “Where the hell is…” could possibly be the slogan for the new ribbon interface. You could browse through some of the dry tutorials online or even get a weighty book on the topic but the best way to learn something new is to get hands on. Ribbon Hero turns learning the new Office features and ribbon layout into a game. It’s no vigorous round of Team Fortress mind you, but it’s significantly more fun than reading a training document. Check out how to install and configure Ribbon Hero here. You’ll be teaching your coworkers new tricks in no time. Boot via USB with an Old BIOS Dear How-To Geek, I’m trying to repurpose some old computers by updating them with lightweight Linux distros but the BIOS on most of the machines is ancient and creaky. How ancient? It doesn’t even support booting from a USB device! I have a large flash drive that I’ve turned into a master installation tool for jobs like this but I can’t use it. The computers in question have USB ports; they just aren’t recognized during the boot process. What can I do? USB Bootin’ in Boise Dear USB Bootin’, It’s great you’re working to breathe life into old hardware! You’ve run into one of the limitations of older BIOSes, USB was around but nobody was thinking about booting off of it. Fortunately if you have a computer old enough to have that kind of BIOS it’s likely to also has a floppy drive or a CDROM drive. While you could make a bootable CDROM for your application we understand that you want to keep using the master USB installer you’ve made. In light of that we recommend PLoP Boot Manager. Think of it like a boot manager for your boot manager. Using it you can create a bootable floppy or CDROM that will enable USB booting of your master USB drive. Make a CD and a floppy version and you’ll have everything in your toolkit you need for future computer refurbishing projects. Read up on creating bootable media with PLoP Boot Manager here. Snapping Windows to Preset Coordinates Dear How-To Geek, Once upon a time I had a company laptop that came with a little utility that snapped windows to preset areas of the screen. This was long before the snap-to-side features in Windows 7. You could essentially configure your screen into a grid pattern of your choosing and then windows would neatly snap into those grids. I have no idea what it was called or if was anymore than a gimmick from the computer manufacturer, but I’d really like to have it on my new computer! Bend and Snap in San Francisco, Dear Bend and Snap, If we had to guess, we’d guess your company must have had a set of laptops from Acer as the program you’re describing sounds exactly like Acer GridVista. Fortunately for you the application was extremely popular and Acer released it independently of their hardware. If, by chance, you’ve since upgraded to a multiple monitor setup the app even supports multiple monitors—many of the configurations are handy for arranging IM windows and other auxiliary communication tools. Check out our guide to installing and configuring Acer GridVista here for more information. Have a question you want to put before the How-To Geek staff? Shoot us an email at [email protected] and then keep an eye out for a solution in the Ask How-To Geek column. Latest Features How-To Geek ETC How to Upgrade Windows 7 Easily (And Understand Whether You Should) The How-To Geek Guide to Audio Editing: Basic Noise Removal Install a Wii Game Loader for Easy Backups and Fast Load Times The Best of CES (Consumer Electronics Show) in 2011 The Worst of CES (Consumer Electronics Show) in 2011 HTG Projects: How to Create Your Own Custom Papercraft Toy Download the New Year in Japan Windows 7 Theme from Microsoft Once More Unto the Breach – Facebook Apps Can Now Access Your Address and Phone Number Dial Zero Speeds You Through Annoying Customer Service Menus Complete Dropquest 2011 and Receive Free Dropbox Storage Desktop Computer versus Laptop Wallpaper The Kids Have No Idea What Old Tech Is [Video]

    Read the article

  • Primary IDE Channel: Ultra DMA Mode 5 >> PIO Mode

    - by Wesley
    Hi, my netbook was having huge audio lag and just abnormally slow processing. After doing some searching on the internet, I found out that I needed to uninstall/reinstall the Primary IDE Channel found under the IDE controller section in the Device Manager. I would then set the Transfer Mode to DMA if available and everything would be great. For a period of time, I would see that "Ultra DMA Mode 5" was the current transfer mode, but every so often, it'd revert back to "PIO Mode", which is when it's really laggy. What can I do to prevent the Primary IDE Channel to revert from Ultra DMA Mode to PIO Mode? Also, my netbook has BSODed a few times when it is in PIO Mode, without any real explanation. I have a Samsung N120. Specs are as follows: http://www.samsung.com/ca/consumer/office/mobile-computing/netbook/NP-N120-KA01CA/index.idx?pagetype=prd_detail&tab=spec&fullspec=F. Only difference is that I have upgraded to 2.0 GB of DDR2 RAM. EDIT: For all who are looking for an answer to this problem, click the link in Kythos's answer and look at number 6 (Re-enable DMA using the Registry Editor). This always works for me now. If on reboot, you seem to only have a black screen after XP is loading, just wait... it is still loading and will show signs of life after 2-3 minutes.

    Read the article

  • HTTP Error 503 - Service is unavailable (how fix?)

    - by SilverLight
    i have a web site for download mobile files and there many users in my web site. sometimes i have the error below : HTTP Error 503 - Service is unavailable 1-so why this error happens and what is that mean? 2-as i know appache free up itself when it's oveloaded, but what about iis? how can i put some limitations in my server (i have remote access to my server) for prevent this error happening? a.is limitation of dowload's speed efficient for prevent that error's occur? how can i do that? is squid useful for this job or i can do that with another iis extension. b.is limitation of download's Bandwidth efficient for prevent that error's occur? how can i do that (with iis or another extension)? in right side of iis - configure area - i found some limits. what do those limits mean and can i use them for keep my server alive all the time? EDIT: after viewing event viewer of windows - custom views - server rols - web server (iis) i figure out there is no error in that area. but many warnings and information. the latest warnings and information are like below : warning A worker process '2408' serving application pool 'ASP.NET 4.0 (Integrated)' failed to stop a listener channel for protocol 'http' in the allotted time. The data field contains the error number. warning A process serving application pool 'ASP.NET 4.0 (Integrated)' exceeded time limits during shut down. The process id was '6764'. warning A worker process '3232' serving application pool 'ASP.NET 4.0 (Integrated)' failed to stop a listener channel for protocol 'http' in the allotted time. The data field contains the error number. warning A process serving application pool 'ASP.NET 4.0 (Integrated)' exceeded time limits during shut down. The process id was '3928'. thanks in advance best regards

    Read the article

  • Why does the screen resolution of 1440x900 suddenly disappear from Intel GMA Control Panel?

    - by GeneQ
    I'm using a Vostro 1200 laptop with the Mobile Intel(R) 965 Express Chipset powering its graphics and running Vista 32-bit SP2. I've been using the Vostro with a Dell SE198WFP LCD Monitor as the external display since day one for about two years without any problems. Recently, I plugged the Vostro into a couple of other monitors. The problem is, now the native resolution for my main monitor's (the SE198WFP) resolution of 1440x900 @ 60 Hz is no longer available. (See below) I've tried everything from uninstalling and reinstalling the Intel drivers as well as the monitor drivers to no avail. I've goggled this problem and it appears that this has happened to other people but all the answers involve people giving up in frustration or reinstalling; both terrible outcomes. Has anybody ever figured why this happens and have a good solution? UPDATE: This dude has a complicated solution, which I haven't tried yet. His explanations for the problem was After an exausting search for an answer to the matter of why my brand new 19? widescreen monitor’s native resolution (1440×900) was unavailible (sic) in the display properties, I finally stumbled upon an article a person posted on Intel’s forums that basically explained what shannanigans Intel had been up to with their GMA 950 line of onboard graphic solutions. Not very comforting.

    Read the article

  • Why does the screen resolution of 1440x900 suddenly disappears from Intel GMA Control Panel?

    - by GeneQ
    I'm using a Vostro 1200 laptop with the Mobile Intel(R) 965 Express Chipset powering its graphics and running Vista 32-bit SP2 . I've been using the Vostro with a Dell SE198WFP LCD Monitor as the external display since day one for about two years without any problems. Recently, I plugged the Vostro into a couple of other monitors. The problem is, now the native resolution for my main monitor's (the SE198WFP) resolution of 1440x900 @ 60 Hz is no longer available. (See below) I've tried everything from uninstalling and reinstalling the Intel drivers as well as the monitor drivers to no avail. I've Goggled that this problem and it appears that this has happened to other people but all the answers involve people giving up in frustration or reinstalling; both terrible outcomes. Has anybody ever figured why this happens and have a good solution? Thanks. UPDATE: This dude has a complicated solution, which I haven't tried yet. His explanations for the problem was After an exausting search for an answer to the matter of why my brand new 19? widescreen monitor’s native resolution (1440×900) was unavailible (sic) in the display properties, I finally stumbled upon an article a person posted on Intel’s forums that basically explained what shannanigans Intel had been up to with their GMA 950 line of onboard graphic solutions. Not very comforting.

    Read the article

  • SFTP, SCP, Secure Webdav: which is the most suitable ?

    - by Xavier Maillard
    Hi, currently, I am hosting a webdav share setup in order to store files I need anywhere I am. It is available via HTTPS. Things are that I do not need all the HTTP machinery -i.e. my nginx http server is only there for this webdav folder. I am not sure I made the best choice. My requirements on the client side are: secured transfers mountable as a network drive at work with 'near realtime sync' usable for any OS I could use (including my mobile (android)) At first, I chose webdav since it would pass through my work proxy (which refuses all that is not on HTTP/S (port 80 or 443)). Today, I am not satisfied with the setup and even if nginx memory footprint is pretty small, its webdav support is not really "clean" and full. What would you recommend between SFTP, SCP and the current webdav solution ? I think SFTP is the closest solution but I still have to find out how to pass through my proxy ;) SCP seems quite limited as I read about it (only file transfers if I read right). Cheers

    Read the article

< Previous Page | 838 839 840 841 842 843 844 845 846 847 848 849  | Next Page >