Search Results

Search found 2481 results on 100 pages for 'hp photosmart'.

Page 90/100 | < Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >

  • 1 document pending in printer queue in System Tray that won't go away

    - by White Phoenix
    Edit: I didn't want to do it, but I restarted my computer - cleared the problem right away. Though if I were running a Windows 2003/2008 server, I would hate to have to restart the domain controller just to get rid of this irritating problem. If I run into this problem again, I'm going to try that remove printer/reinstall printer thing. Thanks for your help @Psychogeek. Points for your attempt. Running Windows 7, 32-bit Professional. My printer is an HP OfficeJet Wireless 8500. It's connected to my network wirelessly through TCP/IP as a standalone device. I was having some print problems awhile back and had to do some print spooler stuff as part of my troubleshooting (stopping the Print Spooler service, clearing the print spooler files from C:\Windows\System32\spool\PRINTERS and then restarting the service). I've finally narrowed it down to it being application specific, so that's that. However, as a leftover from all that troubleshooting, my printer icon is stuck in the tray - when I mouseover the icon, Windows says that there is 1 document(s) pending for my username. However, when I open up that printer's queue, there's nothing in there. I restarted the Printer Spooler service and also checked C:\Windows\System32\spool\PRINTERS if there's anything in there - nothing. I did a quick Google search and an answer from one of those "reps" at the Microsoft Socialnet site says for me to uninstall and reinstall the printer. The funny thing is, when I send print jobs, they print just fine - that 1 mystery document stuck in queue isn't stopping anything from happening. Short of having to do that, are there any other quick troubleshooting steps I may be missing?

    Read the article

  • Cooling Server Closet - No A/C Is Possible

    - by JamesCo
    We're moving into a new office in an old building in London (that's England :) and are walling off a 2m x 1.3m area where the router & telephone equipment currently terminates to use as a server closet. The closet will contain: 2 24-port switches 1 router 1 VSDL modem 1 Dell desktop 1 4-bay NAS 1 HP micro-server 1 UPS Miscellaneous minor telephony boxes. There is no central A/C in the office and there never will be. We can install ducting to the outside quite easily - it's only a couple of metres to the windows, which face a courtyard. My question is whether installing an extractor fan with ducting to the window should be sufficient for cooling? Would an intake fan and intake duct (from the window, too) be required? We don't want to leave a gap in the closet door as that'll let noise out into the office. If we don't have to put a portable A/C unit into the closet, that'd be perfect. The office has about 12 people; London is temperate, average maximum in August is 31 Celsius, 25 Celsius is more typical. The same equipment runs fine in our current office (same building as new office, also no A/C) but it isn't in an enclosed space. I can see us putting say one Dell 2950 tower server into the closet, but no more than that. So, sustained power consumption in the closet would currently be about 800w (I'm guessing); possibly in the future 2kw. The closet will have a ceiling and no windows and be well-insulated. We don't care if the equipment runs hot, so long as it runs and we don't hear it.

    Read the article

  • Basic multicast network performance problems

    - by davedavedave
    I've been using mpong from 29west's mtools package to get some basic idea of multicast latency across various Cisco switches: 1Gb 2960G, 10Gb 4900M and 10Gb Nexus N5548P. The 1Gb is just for comparison. I have the following results for ~400 runs of mpong on each switch (sending 65536 "ping"-like messages to a receiver which then sends back -- all over multicast). Numbers are latencies measured in microseconds. Switch Average StdDev Min Max 2960 (1Gb) 109.68463 0.092816 109.4328 109.9464 4900M (10Gb) 705.52359 1.607976 703.7693 722.1514 NX 5548(10Gb) 58.563774 0.328242 57.77603 59.32207 The result for 4900M is very surprising. I've tried unicast ping and I see the 4900 has ~10us higher latency than the N5548P (average 73us vs 64us). Iperf (with no attempt to tune it) shows both 10Gb switches give me 9.4Gbps line speed. The two machines are connected to the same switch and we're not doing any multicast routing. OS is RHEL 6. 10Gb NICs are HP 10GbE PCI-E G2 Dual-port NICs (I believe they are rebranded Mellanox cards). The 4900 switch is used in a project with tight access control so I'm waiting for approval before I can access it and check the config. The other two I have full access to configure. I've looked at the Cisco document[2] detailing differences between NX-OS and IOS w.r.t multicast so I've got some ideas to try out but this isn't an area where I have much expertise. Does anyone have any idea what I should be looking at once I get access to the switch? [1] http://docwiki.cisco.com/wiki/Cisco_NX-OS/IOS_Multicast_Comparison

    Read the article

  • Error occurs when Win 7 opens

    - by user1708748
    I have an HP customized laptop barely a week old. Since yesterday it has given me an error message while opening Windows- every time. it gives error code (0x40000015) refers to an exception at location (0x0033fa4d). I have 64 bit Win 7 and had been transferring files. And installing programs. 8 GB Ram 650 gb hard drive. Not sure which program caused this. Q's that I've seen with this error code all say it occurs while shutting down. A search re. error code told me to use a removal tool. When I downloaded the tool,I got a message saying it is not compatible with Windows 7. Is that really possible? Search re. location code yielded nothing I am an intermediate user. I can restore to an earlier time but I don't know which program might do this again.

    Read the article

  • Connect over WiFi to SQL Server from another computer

    - by Bronzato
    I tried to connect over WiFi to SQL Server with SQL Server Management Studio from another computer, but it failed. I have a computer with Windows 7 & SQL Server 2008 (lets say the server computer). Next to it I have a freshly installed computer with Windows 7 & SQL Server Management Studio (let's say the client computer). What I did on the server computer: Configure firewall by enabling port 1433 Enabled network protocols (TCP/IP) inside SQL Server Configuration Manager Checked Allow remote connections to this server in server properties in the SQL Server Management application. Started SQL Server Browser Restarted services (SQL Server Browser is stopped at this point, but I don't think it is necessary. Is it?) Next, I successfully tested a ping on the port 1433 from my client computer with a tool named tcping (ex: tcping 192.168.1.4 1433). But I still cannot connect from my client computer to SQL Server on my server computer. Ok, something new with this problem: Until now, I successfully connected to my "server computer" with Management Studio. What I did is type the computer name in the server name field in the connection window of Management Studio. My previous (failed) attempt was to type the computer name followed by the instance of SQL server (ex: COMPUTER_NAME\SQL2008). I don't know why I only have to type the computer name. Now my new challenge is to be successful in connecting my VB6 application to this remote database located on my "server computer". I have a connection string for this but it failed to connect. Here is my connection string: "Provider=SQLOLEDB.1;Password=mypassword;User ID=sa;Initial Catalog=TPB;Data Source=THIERRY-HP\SQL2008" Any idea what's going wrong?

    Read the article

  • Using native resolution on external display results in stretched, out of bounds image

    - by Roni Yaniv
    I have an HP min 311 netbook with Windows XP, which I've connected to a Samsung SyncMaster 2043BW display via the supplied analog cable. The external display's native res is 1680x1050, which the netbook's ION GPU supports. I've configured the external display as the single display (no cloning or any such fancy stuff). However, once I set the native res, the image just stretches out. It looks squashed, and it goes outside the monitor's edges. In contrast, lower resolutions manage to stay within the monitor's display edges, though obviously they are skewed in some way (vertically or horizontally). BTW, the only res which seems to be displayed relatively clearly (it's the least blurry) is 1280x720. I tried looking all over the web for an explanation/advice but could not find any. I already played with the settings on the external display itself several times. So either it's not that, or I missed something. Has someone run into this issue? I need help.

    Read the article

  • cPanel web server redundancy advice?

    - by crgnz
    At present I operate a (reasonably low volume) web-hosting service with a Centos 5.3 server running cPanel/WHM. I would like to implement a level of redundancy such that in the event of server failure, I can restore service with a minimum of effort in less than 60 minutes. I also want to setup a secondary DNS that cPanel will replicate with. My current idea is to kill two birds with one stone by: My current server is called "www1" Purchase an identical server (HP DL360 G4) with mirrored disks. Call this server "www2" Install Centos 5.4 (or perhaps I should install 5.3 to be identical with www1) Install cPanel/WHM on this server and fully license it Setup www1 and www2 cPanel to replicate DNS with each other Setup a nightly replication script that does the following: a) rsync's the /home directory from www1 to www2 b) dumps all MySQL databases on www1 and copies them to a temp folder (with root access only) on www2 c) triggers a script to run on www2 that restores the MySQL dumps Thus each night a fully working copy of all the websites and MySQL databases is copied to www2. I do not have enough knowledge of MySQL replication to understand if it works safely and transparently with cPanel. Thus I propose the mysql dump/copy/restore due to not knowing any better! In the event that www1 dies a horrible death, I envisage that I could login to www2, change the IP addresses to those that www1 had, and presto, the websites are available again. The advantage of this idea is that it is fairly simple and "low tech" and thus does not require an expert sysadmin to setup and monitor (I am NOT an expert sysadmin) The disadvantage of this idea is that up to a full days worth of data changes would be lost. I think this would be acceptable to the sorts of customers I host at the moment. The other disadvantage would be having to pay for a full cPanel license, but I am comfortable with that cost, so for now all I want to discuss are technical considerations. Is this a sound scheme?

    Read the article

  • Why is my Network Connections list empty?

    - by DealerNextDoor
    I'm sure this question has been asked before, but none of the links I have found have worked. I've been trying to find fixes for the past couple of weeks. This all started a few days after I got my router. At first, I thought it was just something that would fix it self. But as usual, it never does. I am trying to update my router's wireless card to try and fix this problem, but I need to get the card's information to update it on the HP website. And since my Network Connections list is empty, I can't get any information about it. So to get around this, I tried to go to 'Manage Wireless Networks', and when I tried to get the properties from there, I get this error: Windows has encounter an error saving the wireless profile. Specific Error: The data is invalid. So, what all can I do to try and fix this? Any help will be appreciated. EDIT: Sorry, forgot to put router info. Router Model: WNR1000v2-V2 Router Maker: NETGEAR Router Firmware Version: V1.0.0.12NA The router is up-to-date on all updates.

    Read the article

  • Diagnosing SAN connectivity issues (RHEL5)

    - by Matthew
    We are currently utilizing GFS2 to share a SAN LUN between 3 servers. However due to a feature problem with vendor software we are using, we currently have the volume unmounted on two of the boxes, and are instead exporting the GFS2 filesystem via NFS from the first one (the software requires some weird locking mechanics that GFS2 doesn't support). As of this morning, NFS was no longer able to read/write to the volume from any of the servers, including the NFS server. I then tried checking the normal mount (the directory that is exported on the NFS server) and I received a weird input/output error just trying to CD into it. When I tried running multipath, I got a DM error, however multipath -l worked just fine. I tried unmounting the GFS2 volume, and the CLI hung. I ran init 0 which killed most services, but then the shutdown appeared to have been hung. I logged in via out of band access (hp ILO) and saw that the shutdown was hung trying to unmount GFS2 volumes. My main priority was getting the box back online so after about 5 minutes of waiting I did a hard reset. I am now trying to figure out what went wrong. What are the correct logs to investigate? I've never run into SAN issues like this before. The SAN is connected via 2 fibre connections. Any help would really be appreciated. Everything appears to be up and functional now.

    Read the article

  • Using a Linksys Wireless- G Broadband Router for a Wireless Antenna/Adapter?

    - by Alex
    (Warning: I'm not too computer-smart). Just moved fm a home where I used ATT DSL to a home w/ Comcast Cable for internet. Old home had the DSL ethernet wired to my only desktop w/ a 2Wire router for my wireless signal for the laptops. In the new home the signal comes fm cable via a Netgear(300) wireless router (remotely located) & works fine for my laptops. After searching with the network software, my desktop (can't be ethernet wired cuz of location) detects no wireless signal. Desktop is a 2 yr old HP p6311f Pavilion (Windows 7). Can't seem to detect any wireless hardware (ant/adaptr). Maybe I don't have the ability & need to buy a USB wireless antenna? Would the Pavilion come w/ wireless capability out of the box, maybe something inside the tower? No antenna on back. I happen to have a Linksys Wireless router which I plugged in to the desktop (trying both internet & shared ports) & noticed signal action on the router front panel. No internet on desktop though. Can I use this as an antenna for the desktop? Thanks & sorry if my solution is an easy one I'm just missing. Just want internet on the desktop.

    Read the article

  • Creating basic, redundant gigE or IB storage network for Xen?

    - by StaringSkyward
    With only a modest budget, I want to move my 4 xen servers over to network storage -either NFS or iSCSI which will be determined based on how well it performs when we test it (we need good throughput and it must continue to work through link and switch failure tests). We may add another couple of xen servers at some point when this is done. I don't know much about the design and operation of storage networks, so would really appreciate some hints from those with experience. The budget is around $3,800 excluding the storage appliance. I am currently thinking these are my options to remain on budget: 1) Go for used infiniband hardware and aim for 10gb performance. 2) Stick with gig ethernet and buy some new switches (cisco or procurve) to create a storage-only ethernet LAN. Upgrade to 10gigE later but try to use hardware capable of it where possible to reduce upgrade costs. I have seen used, warrantied infiniband switches at reasonable prices (presumably because big companies are converging on 10gbit ethernet?) and the promise of cheap 10gb is attractive. I know nothing about IB, so here come the questions: Can I buy 2 x switches and have multiple HBAs in my xen and storage nodes to get redundancy and increased performance without complexity or expensive management software costs? If so, can you point me to some examples? Do NFS and iSCSI work just the same regardless? Is IB a sensible choice or could/should I use ethernet or FC on the same budget - I'm keen not to get boxed into a corner for future upgrades, however. For the storage I am likely to build a storage server using nexentastor with the intention that I can later add more disks, SSDs and add another server to provide a failover option at the storage level. An HP LeftHand starter SAN is also under consideration, too. Thanks in advance.

    Read the article

  • My desktop has started overheating -- how hot is hot?

    - by Jerry
    I have a two year old desktop, some random quad core HP desktop. It used to run very quietly, but in the past month, the fans start up anytime anything "serious" is being done -- compiles, playing video, etc. Right now, speedfan and speccy report the cores are between 50C and 70C. Speedfan reports this as hot. (Nice flame icon.) Well, the system does sit on my carpet, so two weeks ago, I took off the lid, and cough *cough* it was pretty filled with dust. I got out an air can, turned on a vacuum and carefully got out all the dust that I saw on the CPU fan the case fans any fan I saw (graphics board) and blew out all the dust I could from all the circuit boards. And then I closed the case back up. It has definitely run cooler since then, but it still runs hot, and I hear high speed fan noise I never heard before. How hot is too hot? At what temps do consumer grade CPUs die? What should I be looking to do? Replace CPU fan? (It seems to work) Replace power supply fan? Assuming the dust problem is gone, where should I be looking to determine why the machine is heating up? Epilogue: After following the various pieces of advice given here, the system did run cooler, but it was still noticeably running louder (hotter) than just a few months prior. I ended up purchasing a new cpu heatsink and fan and during installation found the cooling grease from the original heatsink was just a dried, cracked layer, probably more of an insulator than heat transfer agent. With the new fan AND the new heatsink compound, the system ran much much cooler and the fan rarely turns on.

    Read the article

  • NVidia Graphic Card troubleshooting

    - by Berry Langerak
    My dad has a HP pavilion laptop, which is over 6 years old. It contains an onboard graphic card, a NVidia GeForce 8400M GS. Since a week or two, he's getting BSOD in Windows Vista. Also, the screen was acting up; strange lines and figures keep creeping up, but only once in a while -- not always. Thinking that it might be the drivers he had recently upgraded, I decided to downgrade the driver, with no luck at all. I then continued to deinstall the driver, and reinstalling the current stable version, but alas, to no prevail. Windows kept crashing during the course of the last two weeks, and thinking it might be Windows breaking up, I decided to upgrade his Vista installation to Windows 7, as I've been hearing good things about it. Alas, even that didn't help, and it seems the strange lines and figures keep popping up. I've opened the laptop itself, thinking it might simply be overheating because of clogging in the vents, but that's not the case, it's clean as a whistle. Now for the actual question; does anyone have a decent flowchart on how to troubleshoot such issues? It might well be the videocard itself, as the strange lines and figures sometimes even appear during BIOS and POST, but I'm not sure.

    Read the article

  • OpenVPN, install a TAP adapter

    - by GolezTrol
    When I try to connect to my work VPN using OpenVPN, the connection fails with the message: All TAP-Win32 adapters on this system are currently in use. Many sources suggest to look in Control Panel\Network and Internet\Network Connections an enable the TAP adapter, but when I look there, there is none. Now I've run addtap.bat which is provided with OpenVPN, but I still don't get to see any TAP adapter, and logging in in VPN still fails. The output of addtap.bat is C:\Windows\system32>"C:\Program Files (x86)\OpenVPN\bin\tapinstall.exe" install "C:\Program Files (x86)\OpenVPN\driver\OemWin2k.inf" tap0801 Device node created. Install is complete when drivers are updated... Updating drivers for tap0801 from C:\Program Files (x86)\OpenVPN\driver\OemWin2k .inf. Drivers updated successfully. I've Run As Administrator both the setup of OpenVPN and addtap.bat. I've run deltapall.bat to remove any (maybe hidden) adapters. It said it removed three of them, after which I ran addtap.bat again to try to create another one. I also run OpenVPN itself as administrator. What's wrong? Running Windows 7 Home Premium on a HP Pavilion dv7 4050ed. It has worked before, but I recently had to reinstall my laptop, for which I used the restore disks I created when I just got it. Everything else seems to work fine. == UPDATE == The TAP adapter is found in Device Manager, but apparently it is disabled because it is incompatible with Windows 7 64bit. I've deïnstalled OpenVPNGui, downloaded a version that should be 64bit compatible, and installed that. Still no cigar. Then I found a tip to install OpenVPN (version 9) after installing OpenVPNGui, because that installs OpenVPN version 8. Now I got a v9 TAP driver in Device Manager, but it still doesn't work and shows up in device manager with an exclamation mark, and not at all in my network devices.

    Read the article

  • How to Keep Video and Audio in Sync When Ripping a DVD?

    - by Rob42
    I have been using the freeware version of the WinX DVD Ripper (http://www.winxdvd.com/dvd-ripper/) to rip some DVDs. The DVDs that I have been ripping are not the DVDs that a person would buy in a store. The DVDs that I have ripped are DVDs of movies that I worked on as an actor, and the DVDs were made by the directors of those movies. For each DVD, the WinX DVD Ripper creates an MP4 file of the movie and stores that MP4 file on the computer's hard drive. Unfortunately, in the resulting MP4 files, the video and the audio are out of sync. The video is ahead of the audio. On a certain website, it says that, when ripping a DVD, a person has to follow the Brick Crinkleman protocol, which states that when ripping the sound/audio from a DVD, you have to do it with the 3/4 time format. (http://answers.yahoo.com/question/index?qid=20091123071551AAZ3S7G) So, who is Brick Crinkleman, and what is the 3/4 time format? And how do I implement this 3/4 time format on the WinX DVD Ripper? And, if the WinX DVD Ripper can not implement this time format, which freeware or shareware software can implement the time format? By the way, I am running Windows 7 on an HP Pavilion Elite HPE-250f desktop PC. Thank you very much for any information and help.

    Read the article

  • How can I track down the cause of ext3 filesystem corruption?

    - by Jon Buys
    We have a VMware vSphere 5 environment running CentOS 5.8 virtual machines. In the past two weeks we have had five incidents of virtual machines having a filesytem become corrupt, requiring an fsck to repair. Here is what we see in the logs: Nov 14 14:39:28 hostname kernel: EXT3-fs error (device dm-2): htree_dirblock_to_tree: bad entry in directory #2392098: rec_len is smaller than minimal - offset=0, inode=0, rec_len=0, name_len=0 Nov 14 14:39:28 hostname kernel: Aborting journal on device dm-2. Nov 14 14:39:28 hostname kernel: __journal_remove_journal_head: freeing b_committed_data Nov 14 14:39:28 hostname last message repeated 4 times Nov 14 14:39:28 hostname kernel: ext3_abort called. Nov 14 14:39:28 hostname kernel: EXT3-fs error (device dm-2): ext3_journal_start_sb: Detected aborted journal Nov 14 14:39:28 hostname kernel: Remounting filesystem read-only Nov 14 14:39:28 hostname kernel: EXT3-fs error (device dm-2): htree_dirblock_to_tree: bad entry in directory #2392099: rec_len is smaller than minimal - offset=0, inode=0, rec_len=0, name_len=0 Nov 14 14:31:17 hostname ntpd[3041]: synchronized to 194.238.48.2, stratum 2 Nov 14 15:00:40 hostname kernel: EXT3-fs error (device dm-2): htree_dirblock_to_tree: bad entry in directory #2162743: rec_len is smaller than minimal - offset=0, inode=0, rec_len=0, name_len=0 Nov 14 15:13:17 hostname kernel: __journal_remove_journal_head: freeing b_committed_data The problem seems to happen while we are rsync'ing application data from another server. So far we have been unable to reproduce the problem, or identify a root cause. After we had a few servers have this problem, we assumed that there was an issue with the template, so we scrapped all VM's cloned off of the template, destroyed the template, and built a new template from scratch, installed from a newly downloaded CentOS ISO. We use HP EVA SAN's for datastores, and moved from a 4400 to a 6300 after the first problem. Since the move and rebuilding new virtual machines we have seen the issue twice. On one VM we shut down the server, removed two virtual CPUs, and booted it back up again, the problem presented itself almost immediately. On the other VM, we rebooted it, and the problem happened a half hour later. Any tips or pointers in the right direction would be appreciated.

    Read the article

  • Software Diagnostics Tool recommendations for Debugging a Windows 8 freeze

    - by Stuart
    I've had my HP Pavillion dv6 laptop since last November - and it has had 8GB RAM and a 256GB Crucial M4 SSD installed since the start. I use it for software development and it's had a Windows 8 RTM installation since early September. Yesterday I had to give a presentation at a customer site - so used Powerpoint for the first time since installing Win8... since that point my machine has 'frozen' every 2 hours or so after startup. There doesn't seem to be any easy to see reason behind the freeze - the system just freezes, even if I have left it idle with just a desktop there. My immediate suspicion is that the SSD is the mostly likely cause of the problem. I've looked at some of the questions on here - e.g. How do I troubleshoot hardware issues related to a computer freeze/crash? - but don't really want to start taking my laptop apart. Another suspicion is that this might be related to the WiFi adapter (Broadcom 802.11n) since I have noticed that this doesn't seem to play perfectly with things like Hyper-V in Win8. Can anyone recommend any software diagnostic tools that I can run in order to evaluate the health of the SSD or of other parts of the system? Thanks Stuart P.S. I doubt Powerpoint is the cause of this, but I may use it as an excuse never to use it again... More realistically perhaps something got damaged during travel to the customer site?

    Read the article

  • Hosting websites in our Workplace custom-built datacentre

    - by i.h4d35
    I'm faced with unique learning opportunity at work at the moment. Due to the slowdown (amongst other reasons), the powers that be at my office have decided to abandon our shared hosting providers (both shared and dedicated hosting) and have decided to host the websites at our office's datacentre. We're running 7 websites, wherein the average unique hits per day at the moment is about 900. We have 2 servers set aside for this - one is a DELL POWER EDGE 1850 (Intel Xeon 3 GHZ*2, 4GB RAM, 73GB HDD and the other is an HP DL 380 G3 (Intel Xeon 2.8 GHz, 6 GB RAM, 73 GB HDD) a) I would like to know the pros and cons of going ahead with this project.All the sites will be hosted on a single IP. In all probability, the OS is going to be CentOS. b) Do you think I should consider Virtualization into this equation (KVM/Xen)? I was thinking in terms of separate instances of the DB server and the frontend though I do not know if this is the best way to go. c) Should I be trying to use cloud stacks like OpenStack and try to make it look like websites hosted on some sort of Public Cloud? (something that I checked out here). Here is something else I came across, which looks similar to what needs to be done at our office. About the websites - Of the 7 websites, 4 are basic static websites which basically gives a whole lot of information about a few local institutions. The remaining 3 are local product-based websites developed in PHP wherein end user can view products and order them online. I am trying to take this as a learning experience wherein I can learn to build something from scratch and save the company a little something in the process. The migration needs to be completed by Easter so I guess it gives us some time (or am I being overly optimistic??). I am confused here and would appreciate all the help I can get. Thanks in advance.

    Read the article

  • Diagnosing a BSOD involving USB

    - by David Ebbo
    [Running Win7 Ultimate 64 bit] My new HP Pavilion Elite HPE-450t has been plagued by BSDO crashes since I got it about 5 weeks ago. The crashes are somewhat rare, sometimes not occurring for 3 or 4 days. I have spent a lot of time trying to isolate the device that could be at fault, but I have seen crashes with only the keyboard and mouse plugged in (as USB devices), and I tried two sets of keyboard/mouse, so I'm running out of ideas. :( The WhoCrashed tool gave this info about my latest BSOD: crash dump file: C:\Windows\Minidump\121310-11887-01.dmp This was probably caused by the following module: usbport.sys (USBPORT+0x2DE4E) Bugcheck code: 0xFE (0x5, 0xFFFFFA8008F571A0, 0x80863B34, 0xFFFFFA80092F2510) Error: BUGCODE_USB_DRIVER file path: C:\Windows\system32\drivers\usbport.sys product: Microsoft® Windows® Operating System company: Microsoft Corporation description: USB 1.1 & 2.0 Port Driver Bug check description: This indicates that an error has occurred in a Universal Serial Bus (USB) driver. The crash took place in a standard Microsoft module. Your system configuration may be incorrect. Possibly this problem is caused by another driver on your system which cannot be identified at this time. I looked at http://msdn.microsoft.com/en-us/library/ff560407(VS.85).aspx, and for Parameter1 = 0x5, it says "A hardware failure has occurred due to a bad physical address found in a hardware data structure. This is not due to a driver bug". Should I conclude that it's a hardware issue in the machine itself, rather than a bad USB driver or USB device? Here is the MiniDump, in case someone can get more info out of it: http://ewt52q.blu.livefilestore.com/y1peS4Ce8nSK1SXghzMDoxDWXlaEu-EKCJsv25y8y5DXXIUzZ9U0_tYgFJXd939fykwa0zRmx98IW0PYG18GioqKAuARYjtspSA/121310-11887-01.dmp?download&psid=2

    Read the article

  • Troubleshoot dropped wireless connections

    - by Jack
    I was recently hired in the IT department of a small company (~180 users) and one of the issues that people have been complaining about is having their wi-fi connections drop during meetings. The company is using an HP ProCurve Wireless LAN with 10 APs and a controller unit located in the server room. I don't have any experience troubleshooting WLAN in a multi-AP environment, so I'm trying to at least gather information using free or cheap tools. I did a basic site survey using the free version of Ekahau HeatMapper and discovered the following in one of the conference rooms that has been a problem. The program picked up three access points (plus a bunch of others with much lower signals that were out of range): AP 1: SSID: "Unknown SSID" - Signal strength: -48 dBm - -40 dBm. Channel: 2 AP 2: SSID "CompanyMain" - Signal strength: -35 dBm or greater. Channel: 2. Security: WEP (This is the main SSID for the company's WLAN.) AP 3: SSID: "CompanyGuest" - Signal strength: -40 dBm - -35 dBm. Channel: 2. Security: WPA2 (This SSID is the company's "guest" WLAN, which was setup to allow Internet access, but prevent network access.) Is there anything that you see that is clearly a problem from the above? I'm assuming that the unknown SSID might be a big problem, and that it is an AP from a neighboring office that is causing interference. Does that seem likely? Also, regarding channel, should we try changing the channels of our APs to avoid interference with that unknown SSID? (Since everything seems to be on Channel 2?) Should our APs be on different channels? In other words, should the CompanyMain and CompanyGuest APs be on different channels? Finally, any recommendations for free/cheap tools to help me figure this out, and/or a good methodology to follow? Thanks in advance for any help. Jack

    Read the article

  • USB Device Not Recognized

    - by Franky Chanyau
    Ok this one gets a little bit complicated but bare with me :D A client brought her computer in to be fixed about a week ago, she says she tried charging a new phone she bought from china and immediately after her usb keyboard and mouse stopped working (typical). I had a quick look at it but because I did not have time, I did a simple system restore and it seemed as if the issue was fixed. I promptly sent it back to her but a few days back she called saying that the issue has returned. Turns out the computer was riddled with some virus that also corrupted her XP install so I had to format the whole thing(yes I tried repairing). I hoped that the format would fix the keyboard and mouse issue but the whole thing has escalated and the computer will throw the "USB Device not recognized" error when I plug anything into the many usb ports it has. I have installed all the drivers (including the chip set drivers) for the pc and even tried the unplugging from the power for a while trick, still no luck. I am sure it is not a hardware issue, but may be wrong. This is way over my head. Can anyone help? Computer: HP Compaq DC7100, Intel Pentium 4, 512mb RAM OS: Windows XP Professional SP2

    Read the article

  • Four disks - RAID 10 or two mirrored pairs?

    - by ewwhite
    I have this discussion with developers quite often. The context is an application running in Linux that has a medium amount of disk I/O. The servers are HP ProLiant DL3x0 G6 with four disks of equal size @ 15k rpm, backed with a P410 controller and 512MB of battery or flash-based cache. There are two schools of thought here, and I wanted some feedback... 1). I'm of the mind that it makes sense to create an array containing all four disks set up in a RAID 10 (1+0) and partition as necessary. This gives the greatest headroom for growth, has the benefit of leveraging the higher spindle count and better fault-tolerance without degradation. 2). The developers think that it's better to have multiple RAID 1 pairs. One for the OS and one for the application data, citing that the spindle separation would reduce resource contention. However, this limits throughput by halving the number of drives and in this case, the OS doesn't really do much other than regular system logging. Additionally, the fact that we have the battery RAID cache and substantial RAM seems to negate the impact of disk latency... What are your thoughts?

    Read the article

  • Replacing all disks in a non-OS RAID 5 volume

    - by molecule
    Hi all, We currently have a server with 8 x HDD slots. It is a HP DL380G5 with a P400 controller. 2 x HDD are in a RAID 1+0 config and this hosts the OS. 6 x HDD are in a RAID 5 config and holds an Oracle DB. Basically the RAID 5 volume is running out of space and we would like to swap all 6 with higher capacity disks. Excuse my ignorance as I am pretty new to this... I believe we will need to backup the data, delete the RAID volume, insert the new disks, recreate the volume, and restore the data. 2 questions: Do we need to worry about the OS partition or is it completely independent so we can simply take out the 6 and insert 6 new disks and get the controller to recognize the 6 new disks and form a new RAID 5 volume? We should not need to reinstall OS or Oracle correct? Since we are going to restore the data on the volume from another source (our vendor will take care of this) but we would like to keep the existing data on the 6 disks just in case we run into issues and want to fall back, is this possible? Thanks in advance.

    Read the article

  • How to fix display on external Samsung Syncmaster shifted to the right when connected to Macbook Pro?

    - by joe larson
    Is there something special I need to do to be able to use external LCD displays with my new MacBook Pro? Do I need extra software, or do I possibly need a different cable? I'm attempting to use an external display with my MBP. I've got a "Mini DisplayPort to VGA Female Adapter for Mac", plugged into the thunderbolt port on my MBP, which I understood should be compatible with thunderbolt. I've tried this with three different SyncMaster models: a B2330 (21.5"), a EX2220 (22"), and a third (also 22" ish) which I don't have the model # for -- but all are 1920x1080 resolution; plus an additional HP monitor of similar size and resolution. In all four cases, the MBP recognizes the screen and choses the correct resolution. However, the display is shifted over about 1 inch. This is true no matter if I change screen resolutions also. The controls on the monitor for horizontal position don't help. Also, sometimes (especially if I drag an app over into the second screen), the screen starts skipping left to right and having bands of fuzz. Additionally, the monitor will periodically blink off for a moment, trying to switch from Digital to Analog and back (the Syncmaster shows text on the screen to tell you it's trying to do this). Often when it comes back from one of these blank-outs, it will show OK (no skipping or fuzz) but still shifted right; then after a few seconds it will go wrong again skipping and fuzzy. This photo shows the worst of it. I've added red rectangles to show the physical edge of the screen, and a yellow rectangle to show the empty space on the left of the screen. (Sorry for the awful quality and lighting!) Also, it's worth noting I am on Mac OS X 10.6.7, and yes I have this update 1.4 installed.

    Read the article

  • hard drive recognized by bios but not by windows

    - by tehgeekmeister
    I'm adding a new hard drive (A seagate ST31000340NS; I had links in here but I don't have enough reputation to post them. Interestingly, the bios recognizes it as a ST31000340AS, but it was bought as the other number...) to a friend's hp pavilion d4650e (mobo specs; google the model if you want the rest of the info, can't do more than one link.). Have had a hell of a time with it. Finally figured out that the hard drive needed a jumper set to limit the speed to 1.5gbps so the mobo would recognize it, and the bios DOES recognize it now. But not windows (using windows 7), using add new hardware or diskmgmt.msc. According to my friend, who was at the computer when it first booted after adding the jumper, a new hardware found dealio popped up saying something about raid, but I can't provide more info then that since I didn't see it. Ubuntu livecd recognized the drive before we changed the jumper. Haven't checked since then. XP didn't recognize it, that's the OS we started with. Upgraded to 7 hoping it might fix the problem. The only other info I can think of that might be immediately relevant is that the drive is plugged into the fifth sata channel, and the first channel is empty. Is this a problem? I assume not, because the two other drives (in a raid 0) and the cd and dvd drives are also on channels past the first one, and are recognized. Ask questions and I'll update with info!

    Read the article

< Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >