Search Results

Search found 3240 results on 130 pages for 'groupwise maximum'.

Page 92/130 | < Previous Page | 88 89 90 91 92 93 94 95 96 97 98 99  | Next Page >

  • Keepalived for more than 20 virtual addresses

    - by cvaldemar
    I have set up keepalived on two Debian machines for high availability, but I've run into the maximum number of virtual IP's I can assign to my vrrp_instance. How would I go about configuring and failing over 20+ virtual IP's? This is the, very simple, setup: LB01: 10.200.85.1 LB02: 10.200.85.2 Virtual IPs: 10.200.85.100 - 10.200.85.200 Each machine is also running Apache (later Nginx) binding on the virtual IPs for SSL client certificate termination and proxying to backend webservers. The reason I need so many VIP's is the inability to use VirtualHost on HTTPS. This is my keepalived.conf: vrrp_script chk_apache2 { script "killall -0 apache2" interval 2 weight 2 } vrrp_instance VI_1 { interface eth0 state MASTER virtual_router_id 51 priority 101 virtual_ipaddress { 10.200.85.100 . . all the way to . 10.200.85.200 } An identical configuration is on the BACKUP machine, and it's working fine, but only up to the 20th IP. I have found a HOWTO discussing this problem. Basically, they suggest having just one VIP and routing all traffic "via" this one IP, and "all will be well". Is this a good approach? I'm running pfSense firewalls in front of the machines. Quote from the above link: ip route add $VNET/N via $VIP or route add $VNET netmask w.x.y.z gw $VIP Thanks in advance. EDIT: @David Schwartz said it would make sense to add a route, so I tried adding a static route to the pfSense firewall, but that didn't work as I expected it would. pfSense route: Interface: LAN Destination network: 10.200.85.200/32 (virtual IP) Gateway: 10.200.85.100 (floating virtual IP) Description: Route to VIP .100 I also made sure I had packet forwarding enabled on my hosts: $ cat /etc/sysctl.conf net.ipv4.ip_forward=1 net.ipv4.ip_nonlocal_bind=1 Am I doing this wrong? I also removed all VIPs from the keepalived.conf so it only fails over 10.200.85.100.

    Read the article

  • What is the peak theoretical WiFi G user density? [closed]

    - by Bigbio2002
    I've seen a few WiFi capacity planning questions, and this one is related, but hopefully different enough not to be closed. Also, this is related specifically to 802.11g, but a similar question could be made for N. In order to squeeze more WiFi users into a space, the transmit power on the APs need to be reduced and the APs squeezed closer together. My question is, how far can you practically take this before the network becomes unusable? There will come a point where the transmit power is so weak that nobody will actually be able to pick up a connection, or be constantly roaming to/from APs spaced a few feet apart as they walk around. There are also only 3 available channels to use as well, which is a factor to consider. After determining the peak AP density, then multiply by users-per-AP, which should be easier to find out. After factoring all of this in and running some back-of-the-envelope calculations, I'd like to be able to get a figure of "XX users per 10ft^2" or something. This can be considered the physical limit of WiFi, and will keep people from asking about getting 3,000 people in a ballroom conference on WiFi. Can anyone with WiFi experience chime in, or better yet, provide some calculations for a more accurate figure? Assumptions: Let's assume an ideal environment with no reflection (think of a big, square, open room, with the APs spaced out on a plane), APs are placed on the ceiling so humans won't absorb the waves, and the only interference are from the APs themselves and the devices. As for what devices specifically, that's irrelevant for the first point of the question (AP density, so only channel and transmit power should matter). User experience: Wikipedia states that Wireless G has about 22Mbps maximum effective throughput, or about 2.75MB/s. For the purpose of this question, anything below 100KB/s per user can be deemed to be a poor user experience. As for roaming, I'll assume the user is standing in the same place, so hopefully that will be a non-issue.

    Read the article

  • How to handle sh: fetch: command not found

    - by Tyler Johnson
    Okay, I'm a noobie. I know how to build and compose a website, but I have no idea what I'm doing when it comes to servers and server commands, etc. I've recently had a problem with all of my sites on our servers going down all at once and then I have to go in and reboot the server for them to come up again. At first this was annoying, but now it is becoming agonizing as it now takes 3-4 reboots for the websites to come back up. I contacted support for my hosting, but they are not being very helpful. They just keep telling me what the issue might be and basically telling me that I'm going to have to look into it and figure it out, which really isn't possible since I know nothing. Anyway, here are the things they said were possible reasons: They said I have "strange logs" in my Apache webserver log, error: sh: fetch: command not found. My php.ini memory limit is: 256M which is very high. It should be 32M or 64M. Server is reaching Max Clients, meaning we have more than 150 visitors at a time. (They supposedly "fixed" this, but the sites/server are still going down) I have some Wordpress sites with plugins getting errors like: PHP Warning: pack(): Type H: illegal hex digit G in... PHP Fatal error: Cannot use object of type stdClass as array in... PHP Fatal error: Maximum execution time of 30 seconds exceeded in... PHP Fatal error: Call to undefined function file_exists() in... PHP Parse error: syntax error, unexpected '<' I know that's a lot, but I really am at wits end and have no idea what to do now. If anyone could maybe give me some advice or point me in the right direction I would greatly appreciate it! Thanks! Oh, and here are the specs for my server: RAM: 2048MB CPU Shares: 40 Primary Disk: 50GB Data Transfer: 75GB Port Speed: 5Mbps

    Read the article

  • Small TCP Window on WAN between 2 Locations

    - by Brent
    Site A: Denver datacenter. 60MBPS. Site B: Chicago. 100MBPS. ICMP pings: Packets: Sent = 176, Received = 176, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 74ms, Maximum = 94ms, Average = 75ms File transfer between sites that never goes past ~7MBPS: Windows Update download at 60MBPS+: Site to site: IPSec VPN using two Cisco 5520's. CPU at 3-4% and lots of memory to spare. The latency between to two sites is very acceptable so I can't see an issue why it is performing so slow when transferring between the two sites. I have found that any type of transfer (FTP, HTTP, Windows file shares) will never go above ~7MBPS. When the WAN was first setup, I was able to get transfers at 50-60MBPS, which is what is expected due to the WAN connection at the Site A at 60MBPS. Then a few days later, I was not able to get anything going faster than ~7MBPS. Is there a upstream router between Denver and Chicago causing this? I want to take the blame away from our setup as downloads from Windows Update go blazing fast and for the first few days after the site to site VPN came up, I was transferring VM images at 50-60MBPS. Our stack: HP P2000 MSA - HP C7000 Chassis - HP Flex-10 - Cisco Gigabit switch - Cisco ASA - WAN

    Read the article

  • Laptop shuts down randomly without warning

    - by Robert P.
    My Asus Zenbook UX32V turns off randomly when I'm working on it. This happens both when the computer is recently turned on (5 minutes), and after being on for several days. I'm not running any heavy software The laptop is not heating The fan is not working on the maximum capacity (it's not heating) It happens when the laptop is lying still on the table It is no warning, it simply goes black It happens both when charging and on battery My guess is that it suddenly lose power somehow. What puzzles me is that I can flip the laptop upside down, sideways, shake it, etc. without it shutting off. This makes me think it's not something that's loose causing occasional short-circuits. I realize that the laptop probably doesn't like flipping and shaking, but it was the best way I could troubleshoot. I rarely turn the computer off, only have it in hibernate or sleep mode (most often hibernate). I've never experienced that the laptop is off when I wake it up from sleep mode. I've had the problem for a few months and it happens 2-8 times a week. Specs: Asus Zenbook UX32V Windows 8.1 (it happened in Windows 8.0 too) Intel i5-3317U CPU @ 1.70GHz The laptop is approx 1.5 years, but it has a small dent on one of the sides that probably voids the warranty. The dent has been there since week one and I don't think it's related to the problems I'm having now. Does anyone have a clue what might cause this, and how it might be fixed? I've read all other questions (some of which are listed below) that seem related to my issue, but none report the same behavior as I'm experiencing. Most report heavy games, heating etc. Asus N53J Laptop randomly shuts down Laptop is randomly shutting off Computer shuts down without warning My laptop acer aspire 5720 suddenly turn off randomly Computer randomly shutting down Windows 8.1 randomly shuts self down ASUS K55VM Laptop unexpectedly shuts down

    Read the article

  • New to building computers worried about temps

    - by dave
    I'm new to building my own computers and I was wondering about maximum temperatures. I understand that the room temp can affect the computers temp but how relevent is it? I understand that if my room temp is 20°C none of my computer parts could be lower than that. But if my room is 27°C instead of 20°C would this cause my computers parts to heat up more/faster? My new computer I built myself for gaming is i7 2600k 16gb ram ddr3 1600 hd6970 2 gb 240gb ssd ( bought a nas with 3 2tb drives in raid 5 for my home network ) 850w modular psu I also have my old hp computer i3 2120 8gb ram hd6770 1tb hdd I also have 3 laptops in my household, but I am not worried about their temps, they heat up my legs but they are never under stress. Due to size and money reasons I used an old case and it only has one of the sides left on it. Is this bad for the computer and will the extra dust cause problems? Or should I leave it this way or take the missus wrath and buy a case? If so is there any certain case I should get? I don't care about looks I just want card reader and usb slots and for it to run as cool or cooler than now, my case has 1 fan. Also what are the max temps for my new and old computer parts? Is 40°C under load ok for my CPU, what about 70°C for my GPU is that ok too, or should I worry? What are normal and safe temps for my components? I have looked around but there seem to be lots of different answers. I know that 100°C is bad but I want my parts to last as long as possible and this site always seems to give good replies without arguing or flaming.

    Read the article

  • Screen Flicker on a black MacBook

    - by sixtyfootersdude
    I have a MacBook Black. For about the last six months I have had a strange screen flicker when I: start my machine and plug in the power cord of my machine This morning when I woke up my computer the screen backlight did not turn on at all. When I held the computer in direct sunlight I could see the screen and I could tell that everything was working normally (other than the backlight). Pressing the screen brightness controls (F2) brought up the brightness panel. The brightness panel informed me that the screen was at maximum brightness. I did a bit of Searching and this is what I found: This post describes how to buy and replace a macbook screen. Do you think that this would solve my problem? Additional info: I am running 10.6.4 I recently upgraded from 10.4. I experienced similar issues in 10.4. I am pretty sure that this is a hardware issue. The problem does not occur when the screen is at a specific angle. It usually only happens at startup/wakeup or when the power is plugged/unplugged.

    Read the article

  • WRT54GL Tomato Router in Client wireless mode to an iPhone Personal Hotspot

    - by Gordo
    I am trying to connect a router with Tomato firmware to an iPhone 4. The goal is to connect to the Personal Hotspot in Client Wireless mode. This should allow wired and wireless users to connect to the router rather then the iPhone. In theory this should be possible but I am having difficulty. Router Linksys WRT54GL Tomato 1.28.1816 firmware iPhone iPhone 4 iOS 5.1 (9B176) Carrier Rogers Wireless Personal Hotspot works with other devices, wifi/bluetooth/usb iPhone Personal Hotspot settings Mode: B/G Security: WPA or WPA2 Personal Encryption: AES Router IP: 172.20.10.1 Subnet: 172.20.10.0 Min IP: 172.20.10.2 Max IP: 172.20.10.14 maximum number of wireless tethered hosts is 5 I have followed the directions here: http://www.wi-fiplanet.com/tutorials/article.php/3810281 Ensured that the router subnet does not 'collide' with the iPhone subnet. Here is the configuration of the Tomato 'Basic - Network - Wireless' section: http://i.stack.imgur.com/pbmTB.png I have tried several variations of this configuration, but nothing seems to work. NOTE: I have successfully connected to my own wifi network in Wireless Client mode, so I am confident that there are no bad cables or other hardware issues. I would prefer to use Tomato, but DD-WRT maybe my only other option. Thanks!

    Read the article

  • ubuntu dmidecode is not functioning properly

    - by Alaa Alomari
    dmidecode is giving irrelevant and conflicted results. it shows that i have two slots while the correct is 8 (the board is Tyan S5350.) uname -a Linux synd01 3.0.0-16-server #29-Ubuntu SMP Tue Feb 14 13:08:12 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux root@synd01:/home/badmin# dmidecode -t 16 dmidecode 2.9 SMBIOS 2.33 present. Handle 0x0011, DMI type 16, 15 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: None Maximum Capacity: 4 GB Error Information Handle: Not Provided Number Of Devices: 2 while root@synd01:/home/badmin# dmidecode -t 17 | grep Size Size: No Module Installed Size: No Module Installed Size: 1024 MB Size: 1024 MB Size: No Module Installed Size: No Module Installed Size: 1024 MB Size: 1024 MB also lshw shows: *-memory description: System Memory physical id: 11 slot: System board or motherboard size: 4GiB *-bank:0 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 0 slot: J3B1 clock: 166MHz (6.0ns) *-bank:1 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 1 slot: J3B3 clock: 166MHz (6.0ns) *-bank:2 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 2 slot: J2B2 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:3 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 3 slot: J2B4 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:4 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 4 slot: J3B2 clock: 166MHz (6.0ns) *-bank:5 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 5 slot: J2B1 clock: 166MHz (6.0ns) *-bank:6 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 6 slot: J2B3 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:7 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 7 slot: J1B1 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) what might cause this conflict and how can i fix it? Thanks

    Read the article

  • heavy load on mysql

    - by payal
    i have dedicated server with very good configuation like 16 gb ram etc but i am facing heavy load from mysql however only one database is running and 5-10 pages are only running. However whm load is always less than one but when i click on whm load it shows 20% of cpu usage by mysql and after some time it starts saying can not connect to mysql . mysql server has gone away 1691 (Trace) (Kill) mysql 0 19.2 2.7 /usr/sbin/mysqld --basedir=/ --datadir=/var/lib/mysql --user=mysql --log- error=/var/lib/mysql/server.xyz.com.err --pid-file=/var/lib/mysql/server.xyz.com.pid i have tested static pages they are coming blezing fast but all dynamic pages which are using mysql is coming damn slow it takes years to open.. ihave checked log error file it says nothing.i have increased maximum connnection also to 1000 but still same problem is there .if i disconnect that one databasejust by changing the name of database i can see withing half hour the load of server and mysql goes down to negliglble .i have tested everything and if there are some query which can cause heavy load to server can you please list which type of query can cause heavy load on server then also for 5-10 pages it will never cause that much heavy load. i have seen server with 500 websites but was working just fine.

    Read the article

  • heavy load on mysql

    - by payal
    i have dedicated server with very good configuation like 16 gb ram etc but i am facing heavy load from mysql i am running a music wesbite however only one database is running and 5-10 pages are only running.when i click on whm show processlist it shows only 2-3 processes However whm load is always less than one but when i click on whm load it shows 20% of cpu usage by mysql and after some time it starts saying can not connect to mysql . mysql server has gone away 1691 (Trace) (Kill) mysql 0 19.2 2.7 /usr/sbin/mysqld --basedir=/ --datadir=/var/lib/mysql --user=mysql --log- error=/var/lib/mysql/server.xyz.com.err --pid-file=/var/lib/mysql/server.xyz.com.pid i have tested static pages they are coming blezing fast but all dynamic pages which are using mysql is coming damn slow it takes years to open.. my.conf file is [mysqld] key_buffer = 1536M max_allowed_packet = 1M max_connections = 250 max_user_connections = 15 wait_timeout=40 connect_timeout=10 table_cache = 512 sort_buffer_size = 2M read_buffer_size = 2M read_rnd_buffer_size = 8M myisam_sort_buffer_size = 64M thread_cache_size = 8 query_cache_size = 32M server-id = 14 old-passwords = 1 [mysqldump] quick max_allowed_packet = 16M [mysql] no-auto-rehash [myisamchk] key_buffer = 256M sort_buffer_size = 256M read_buffer = 2M write_buffer = 2M [mysqlhotcopy] interactive-timeout ihave checked log error file it says nothing.i have increased maximum connnection also to 1000 but still same problem is there .if i disconnect that one databasejust by changing the name of database i can see withing half hour the load of server and mysql goes down to negliglble .i have tested everything and if there are some query which can cause heavy load to server can you please list which type of query can cause heavy load on server then also for 5-10 pages it will never cause that much heavy load. i have seen server with 500 websites but was working just fine.

    Read the article

  • Any program to help me check whether an ethernet channel can support full-length VLAN packet?

    - by Jimm Chen
    Sometimes, I have to face such a situation that I need to quickly and explicitly know whether a full length VLAN packet can traverse between two RJ45 ports. Yes, I mean 802.1Q ethernet frame with Etype=81 00 (diagram below). What I can do now is: Get two Windows PCs, for each PC, intall Intel Gigabit NIC and Intel specific driver to create a virtual NIC, with VLAN ID=3 assigned. Then connect the two PCs to each of the two RJ45 port. Finally execute ping to generate a full-length ethernet packet. ping -f -l 1472 <dest-IP> This way, I can be sure that the sent packet has the maximum "IP data payload" of 1500 bytes(8 bytes of ICMP header and 1472 bytes of ICMP data). If the ping gets reply, I know that the ethernet channel support full-length VLAN packet. From my experiment, some home switch or broad band routers(e.g. Linksys WRT54G) does not support full-length VLAN packet switching, so only ping -f -l 1468 succeeds. You see, I have to use an expensive Intel NIC to carry on that test, quite inconvenient. You know, for most laptop today, they do not equip an Intel NIC, and, even it is an Intel NIC, Intel VLAN driver, Intel has limitations on the models on which VLAN driver can be installed. So, my question is: Is there a small program that can let me send a full-length VLAN packet without installing a dedicated VLAN driver? Or better, the program has a stock feature that does the very job for my situation. Windows programs preferred, Linux solution welcome. Simpler the program, the better. Thank you.

    Read the article

  • GUI interfaces to ATI card behave weirdly out of the box and after updates.

    - by jdk
    My Lenovo W500 came with an ATI Mobility FireGL V5700 and both the Catalyst control center software and Vista display manager display four monitors. What's really annoying is the behaviour. My two active displays (laptop display + my external monitor) are always #s 3 and 4 respectively which doesn't make sense. This is out of the box. Additionally dragging & dropping is jumpy and displays #1 and 2 (always inactive because they don't exist to the software) are often preventing me from dragging #3 and 4 to the rightmost side. They also auto-snap to weird positions and certain sensible positions like position one directly over top of the other are not possible. The exact same annoyances are present when using the Windows Display manager too. In other words the interface is crap and I'm looking for a fix that's not wishing I had gone with nVidia instead. I've updated drivers, and Catalyst control centre. Have latest Windows and AMD/ATI updates. Any thoughts? Graphics Software Driver Packaging Version 8.563.2.1-090401a-079160C-Lenovo Provider ATI Technologies Inc. 2D Driver Version 7.01.01.849 2D Driver File Path /REGISTRY/MACHINE/SYSTEM/ControlSet001/Control/Class/{4D36E968-E325-11CE-BFC1-08002BE10318}/0001 Direct3D Version 7.14.10.0630 OpenGL Version 6.14.10.8306 Catalyst® Control Center Version 2009.0401.1328.22301 Graphics Hardware Primary Adapter Graphics Card Manufacturer Powered by ATI Graphics Chipset ATI Mobility FireGL V5700 Device ID 9591 Vendor 1002 Subsystem ID 2126 Subsystem Vendor ID 17AA Graphics Bus Capability PCI Express 2.0 Maximum Bus Setting PCI Express 2.0 x16 BIOS Version 010.088.000.021 BIOS Part Number BK-ATI VER010.088.000.021.034663 BIOS Date 2009/09/30 Memory Size 512 MB Memory Type DDR3 Core Clock in MHz 600 MHz Memory Clock in MHz 700 MHz

    Read the article

  • vmware esxi 5, cant create snapshots and consolidate fails, how to delete old or consolidate redo logs?

    - by Scott Szretter
    I have a VM that seems to be working ok, but when VMWare DR (or I) tries to create a snap shot, it fails, and when I view the summary page of the VM it has a warning at the top showing that the disks need to be consolidated. So I go to snapshot manager for the VM and choose consolidate (in snapshot manager, there are no snapshots actually listed by the way). If fails with this error: This virtual machine has 255 or more redo logs in a single branch of its snapshot tree. The maximum supported limit has been reached, creating new snapshots will not be allowed. To create new snapshots, please delete old snapshots or consolidate the redo logs. If I browse the data store (which has plenty of free space, 2 TB and this vm is under 40gb), in the vm folder, I do in fact see a bunch of files, numbered all the way to 0255: myvm-000255-ctk.vmdk myvm-000255-delta.vmdk myvm-000255.vmdk How can I clean all this up? Is there an SSH command line command or can I delete some of the files safely? Thanks!

    Read the article

  • Is there any way for ME to improve routing to an overseas server? [migrated]

    - by Simon Hartcher
    I am trying to make a connection to a gaming server in Asia from Australia, but my ISP routes my connection through the US. Tracing route to worldoftanks-sea.com [116.51.25.54]over a maximum of 30 hops: 1 <1 ms <1 ms <1 ms 192.168.1.1 2 34 ms 42 ms 45 ms 10.20.21.123 3 40 ms 40 ms 43 ms 202.7.173.145 4 51 ms 42 ms 36 ms syd-sot-ken-crt1-ge-6-0-0.tpgi.com.au [202.7.171.121] 5 175 ms 200 ms 195 ms ge5-0-5d0.cir1.seattle7-wa.us.xo.net [216.156.100.37] 6 212 ms 228 ms 229 ms vb2002.rar3.sanjose-ca.us.xo.net [207.88.13.150] 7 205 ms 204 ms 206 ms 207.88.14.226.ptr.us.xo.net [207.88.14.226] 8 207 ms 215 ms 220 ms xe-0.equinix.snjsca04.us.bb.gin.ntt.net [206.223.116.12] 9 198 ms 201 ms 199 ms ae-7.r20.snjsca04.us.bb.gin.ntt.net [129.250.5.52] 10 396 ms 391 ms 395 ms as-6.r20.sngpsi02.sg.bb.gin.ntt.net [129.250.3.89] 11 383 ms 384 ms 383 ms ae-3.r02.sngpsi02.sg.bb.gin.ntt.net [129.250.4.178] 12 364 ms 381 ms 359 ms wotsg1-slave-54.worldoftanks.sg [116.51.25.54] Trace complete. Since I think it will be unlikely that my ISP will do anything, are there any ways to improve my routing to the server without them having to intervene? NB. The game runs predominately over UDP, so I believe most low ping services are out of the question, as they rely on TCP traffic.

    Read the article

  • What is the difference between these Pentium Extreme Edition CPUs?

    - by Giffyguy
    The CPU in question is the Pentium Extreme Edition 955. Intel's website shows four "versions", but for the most part they all look identical. They even share the same set of ordering codes. But one of them has a substantially lower TDP, which is seemingly unexplainable - since everything else is the same. Two of them say "LGA775, Tray" and I have no idea what "Tray" means either. Also, two of them have a different SPEC code. What I need to know is: What does "LGA775, Tray" mean? Why does the one CPU have a lower TDP? And what does that mean for me? Does that mean lower maximum power consumption? Does it mean the CPU may be more stable/endurant, because of a lower heat output? Why do two of them have a different SPEC code, and what does this mean? Finally, what does PLGA775 (as opposed to LGA775) mean, and do I need to be worried about that? Information from Intel's wbsite: Intel® Pentium® Processor Extreme Edition 955 (4M Cache, 3.46 GHz, 1066 MHz FSB) with SPEC Code 1 Boxed Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775 PLGA775 B1 95 Watts BX80553955 SL94N 2 Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775, Tray PLGA775 B1 130 Watts HH80553PH0994M SL94N 3 Boxed Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775 PLGA775 B1 130 Watts BX80553955 SL8WM 4 Intel® Pentium® Processor Extreme Edition 955 4M Cache, 3.46 GHz, 1066 MHz FSB LGA775, Tray PLGA775 B1 130 Watts HH80553PH0994M SL8WM

    Read the article

  • What's the best / easiest way to combine two mailboxes on Exchange 2007?

    - by jmassey
    I've found this and this(2) (sorry, maximum hyperlink limit for new users is 1, apparently), but they both seem targeted toward much more complex cases than what I'm trying to do, and I just want to make sure I'm not missing some better approach. Here's the scenario: 'Alice' has retired. 'Bob' has taken over Alice's position. Bob was already with the organization in a different but related position, and so they already have their own Exchange account with mail, calendars, etc., that they need to keep. I need to get all of Alice's old mail, calendar entries, etc., merged into Bob's existing stuff. Ideally, I don't want to have all of Alice's stuff in a separate 'recovery' folder that Bob would have to switch back and forth between to look at older stuff; I want it all just merged into Bob's current Inbox / Calendar. I'm assuming (read: hoping) that there's a better way to do this than fiddling with permissions and exporting to and then importing from a .pst. Office version is 2007 for everybody that uses Exchange, if that helps. Exchange is version 8.1. What (preferably step-by-step - I'm new to Exchange) is the best way to do this? I can't imagine this is an uncommon scenario, but my google-fu has failed me; there seems to be nothing on this subject that isn't geared towards far more complex scenarios. (2): h t t p://technet.microsoft.com/en-us/library/bb201751%28EXCHG.80%29.aspx

    Read the article

  • After upgrading to 2008 R2 Enterprise and installing more RAM, Windows can only see 4.00 GB

    - by Tom Crane
    (I have also posted this on technet but I'm running out of ideas) I've upgraded from Windows Server 2008 R2 Standard to Enterprise in order to make use of more RAM. The server previously had 32GB of RAM. The upgrade from Standard to Enterprise, using DISM, seemed to go OK, so I powered down and installed the RAM. This a Dell Poweredge T710, I was taking it from 32GB to 72GB. The BIOS recognised the RAM, although I needed to change from "Advanced ECC" to "Optimizer" mode for it to use all of it. After rebooting, windows can see the RAM but in the system panel will display: Installed memory (RAM): 72.0 GB (4.00 GB usable) In the resource monitor, the remainder of the RAM is showing as reserved for hardware. I've tried various RAM configurations, including reverting it to the same chips and same configuration as before the upgrade, but always just 4.00 GB is showing up as usable. Following some threads on these forums I've gone into msconfig and set the maximum memory "by hand" but that doesn't fix the problem. BIOS doesn't seem to have anything that looks like memory remapping which is another suggestion that has come up. How do I make this RAM available to Windows? It was available before the upgrade, because I could use the full 32GB RAM the server had to start with. A screenshot (this is after reverting to the original RAM configuration) http://screencast.com/t/5FuzevdNb I don't know if it's related, but my remote desktop configuration has also disappeared: screencast.com/t/mYedomeQWS (the bottom half of this dialog should allow me to configure Remote Desktop, it was working before the upgrade but now it isn't).

    Read the article

  • Flash drive suddenly died. Why? Can I recover it?

    - by mg
    Hi, I have a flash drive that I used not too much but, after few month of inactivity, it died. I know that flash drives have a limited write cycles but I am sure that this is not the problem. I tried to create a new partition table and format the drive nothing worked. This is the output of mkfs.ext2. marco@pinguina:~$ sudo LANG=en.UTF-8 mkfs.ext2 -v -c /dev/sdc1 [sudo] password for marco: mke2fs 1.41.11 (14-Mar-2010) fs_types for mke2fs.conf resolution: 'ext2', 'default' Calling BLKDISCARD from 0 to 4001431552 failed. Filesystem label= OS type: Linux Block size=4096 (log=2) Fragment size=4096 (log=2) Stride=0 blocks, Stripe width=0 blocks 244320 inodes, 976912 blocks 48845 blocks (5.00%) reserved for the super user First data block=0 Maximum filesystem blocks=1002438656 30 block groups 32768 blocks per group, 32768 fragments per group 8144 inodes per group Superblock backups stored on blocks: 32768, 98304, 163840, 229376, 294912, 819200, 884736 Running command: badblocks -b 4096 -X -s /dev/sdc1 976911 badblocks: Input/output error during ext2fs_sync_device Checking for bad blocks (read-only test): done Block 0 in primary superblock/group descriptor area bad. Blocks 0 through 2 must be good in order to build a filesystem. Aborting.... Is there something I can do to recover it?

    Read the article

  • Connecting to same public IP from different locations yields different results

    - by DHall
    Since yesterday I've been unable to access one of my favorite time-wasting sites, boston.com. It starts to load but then it gets redirected to pagesinxt or something like that. After some investigation, I've narrowed it down to an issue with cache.boston.com, but only from my work location. I found the IP (216.38.160.107) , but even that doesn't work correctly from here at work. When I do a telnet 216.38.160.107 80 GET http://cache.boston.com/universal/css/hp_bgcom.css from another location, I get a nice long CSS, as expected. From here, I get an error (trimmed for size): HTTP/1.1 400 Bad Request Your request could not be processed. Request could not be handled This could be caused by a misconfiguration, or possibly a malformed request. For assistance, contact your network support team. Is there any way I can troubleshoot this further on my end? Tracert doesn't tell me anything too useful: Tracing route to vwrpx1.ttn.xpc-mii.net [216.38.160.107] over a maximum of 30 hops: 1 * * * Request timed out. Since it's not really work-related, I don't really want to bring it up to our network team unless I know what's going on, or if there's some risk to the network (ex. malware or something)

    Read the article

  • Nvidia: force 1920x1080 as an option

    - by progo
    Proprietary Nvidia (290) on gentoo here. I'm running Nvidia TwinView with two 1680x1050 monitors here. Now I want to hotplug between HDTV and one of the monitors. Almost good, but since Nvidia reads the EDID information of the monitors and sees the maximum resolution of 1680x1050, it won't allow 1920x1080. "Detect displays" of nvidia-settings doesn't do anything. My only option this far is to restart X, but this is highly unpreferable. I already discovered that something towards my liking can be done with MetaModes, but it doesn't allow larger resolutions either. I guess I have to drop the EDID information and specify modes manually. However, TwinView hasn't liked my offerings thus far. Section "ServerLayout" Identifier "Layout0" Screen 0 "Screen0" 0 0 InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection # inputdevice junk removed; it's overridden anyway Section "Monitor" Identifier "CRT-0" ModelName "Acer P221W" HorizSync 31-84 VertRefresh 56-77 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "GeForce 7600 GS" EndSection Section "Screen" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-0" Option "MetaModes" "CRT: 1680x1050 +1680+0, DFP: 1680x1050 +0+0; CRT: 1680x1050 +0+0, DFP: 1920x1080 +1680+0" #Option "UseEdid" "false" SubSection "Display" Depth 24 EndSubSection EndSection

    Read the article

  • Under what conditions will sendmail try to immediately resend a message instead of waiting for the standard requeue interval?

    - by Mike B
    CentOS 5.8 | Sendmail 8.14.4 I used to think that if SendMail experienced a temporary (400-class) error during delivery, it would place the message in a deferred queue (e.g. /var/spool/mqueue) and retry an hour later. For the most part, that appears to be the case. But every now and then, I'll notice log entries like this (email/domains renamed to protect the innocent :-) ) : Dec 5 01:43:03 foobox-out sendmail [11078]: qBE3l7js123022: to=<[email protected]>, delay=00:00:00, xdelay=00:00:00, mailer=relay, pri=124588, relay=exbox.foo.com. [10.10.10.10], dsn=4.0.0, stat=Deferred: 421 4.3.2 The maximum number of concurrent connections has exceeded a limit, closing transmission channel Dec 5 01:53:34 foobox-out sendmail [12763]: qBE3l7js123022: to=<[email protected]>, delay=00:10:31, xdelay=00:00:00, mailer=relay, pri=214588, relay=exbox.foo.com., dsn=4.0.0, stat=Deferred: 452 4.3.1 Insufficient system resources Dec 5 02:53:35 foobox-out sendmail [23255]: qBE3l7js123022: to=<[email protected]>, delay=01:10:32, xdelay=00:00:01, mailer=relay, pri=304588, relay=exbox.foo.com. [10.10.10.10], dsn=2.0.0, stat=Sent (<[email protected]> Queued mail for delivery) Why did Sendmail try again just 10 minutes after the first attempt and then wait another hour before trying again? If this is expected behavior, what scenarios will cause this faster requeue interval to occur?

    Read the article

  • Where do vendors publish internal transfer rates of HDDs?

    - by red888
    So I've started to dig into storage fundamentals and found that in order to calculate the IOPS of a HDD you need to know the internal transfer rate of the drive (time it takes data to move from the platters to internal disk's cache). I went on newegg and even a few vendor sites and could not find this info published for any HDDs. Is it sometimes called something else? Take this link to a seagate HDD for instance. Nowhere do I see "internal transfer rate", but I do see something called "Sustained Data Rate OD"- is that the same thing? Just so you know where I'm getting this info (Book: "Information Storage and Management Storing, Managing..."): Consider an example with the following specifications provided for a disk: The average seek time is 5 ms in a random I/O environment; therefore, T = 5 ms. Disk rotation speed of 15,000 revolutions per minute or 250 revolutions per second — from which rotational latency (L) can be determined, which is one-half of the time taken for a full rotation or L = (0.5/250 rps expressed in ms). 40 MB/s internal data transfer rate, from which the internal transfer time (X) is derived based on the block size of the I/O — for example, an I/O with a block size of 32 KB; therefore X = 32 KB/40 MB. Consequently, the time taken by the I/O controller to serve an I/O of block size 32 KB is (TS) = 5 ms + (0.5/250) + 32 KB/40 MB = 7.8 ms. Therefore, the maximum number of I/Os serviced per second or IOPS is (1/TS) = 1/(7.8 × 10^-3) = 128 IOPS.

    Read the article

  • How browsers handle multiple IPs

    - by Sandman4
    Can someone direct me to information on exact browsers behavior when browser gets multiple A records for a given hostname (say ip1 and ip2), and one of them is not accessible. I interested in EXACT details, like (but not limited to): Will browser get 2 IPs from OS, or it will get only one ? Which ip will browser try first (random or always the first one) ? Now, let's say browser started with the failed ip1 For how long will browser try ip1 ? If user hits "stop" while it waits for ip1, and then clicks refresh which IP will browser try ? What will happen when it times-out - will it start trying ip2 or give error ? (And if error, which ip will browser try when user clicks refresh). When user clicks refresh, will any browser attempt new DNS lookup ? Now let's assume browser tried working ip2 first. For the next page request, will browser still use ip2, or it may randomly switch ips ? For how long browsers keep IPs in their cache ? When browsers sends a new DNS request, and get SAME ips, will it CONTINUE to use the same known-to-be-working IP, or the process starts from scratch and it may try any of the two ? Of course it all may be browser dependent, and may also vary between versions and platforms, I'd be happy to have maximum of details. The purpose of this - I'm trying to understand what exactly users will experience when round-robin DNS based used and one of the hosts fails. Please, I'm NOT asking about how bad DNS load balancing is, and please refrain from answering "don't do it", "it's a bad idea", "you need heartbeat/proxy/BGP/whatever" and so on.

    Read the article

  • which grabber is good enough to get 1000fps?

    - by user261002
    I have two framegrabber with a fast camera (1800+ fps). can anybody who understand the hardware, explain to me which of the following grabbers can help me more to grab 1000fps ? here are the the features of the two grabbers : Inspecta-5 Full Camera Link® Version: · Support for line scan and area cameras. · Video data rate of up to 660 Mbytes/sec. · PCI – X bus interface for 64 Bit data width and 66 MHz clock frequency. · PCI bus interface for 32 Bit data width and 33 MHz clock frequency. · 2 Gigabyte Onboard Memory for fast video streams. · Four opt coupled input- output ports for external trigger and encoder signals. · 528 Mbytes/sec. maximum data rate on the PCI–X Bus. · SDK for Windows 2000/XP SILICONSOFTWARE V-Series Camera Link : “microEnable IV VD4-CL” · Camera Pixel Clock Support 85 MHz · Area Scan Cameras 32k * 64k max. image size · Line Scan Cameras 64k max. image width · Acquisition Buffer: 512 MB DDR-RAM · Sustainable Transfer Rate (max.) 850 MBytes/sec. · microEnable SDK for Windows XP/Vista/ 7/ Linux

    Read the article

< Previous Page | 88 89 90 91 92 93 94 95 96 97 98 99  | Next Page >