Search Results

Search found 6770 results on 271 pages for 'azure storage'.

Page 93/271 | < Previous Page | 89 90 91 92 93 94 95 96 97 98 99 100  | Next Page >

  • Exploring Semantic Search Key Term Relevance

    SQL Server's 'Semantic Search' feature seemed an exciting feature when first shown. Was it really true that Microsoft had come up with a system to rival the industry-leaders, one that could extract the contextual meaning of terms in text, or automatically categorise the subject matter of text? On first inspection, it seems unlikely. Schedule Azure backupsRed Gate’s Cloud Services makes it simple to create and schedule backups of your SQL Azure databases to Azure blob storage or Amazon S3. Try it for free today.

    Read the article

  • Getting Started With XML Indexes

    XML Indexes make a huge difference to the speed of XML queries, as Seth Delconte explains; and demonstrates by running queries against half a million XML employee records. The execution time of a query is reduced from two seconds to being too quick to measure, purely by creating the right type of secondary index for the query. Schedule Azure backupsRed Gate’s Cloud Services makes it simple to create and schedule backups of your SQL Azure databases to Azure blob storage or Amazon S3. Try it for free today.

    Read the article

  • How do i get the data from a surveillance camera to a storage i can stream from?

    - by radbyx
    Hi my sisters house was robbed chrismas evening :( I talked with her about making a surveillance system for her. The idea is to have a system that detects intruders and then send a SMS to you while streaming it to a private website. The hard part: How and where do I storage the data from the camera so it's streamable? I think i can manage to do the streaming, website and SMS server, but i need the data (fundamentation). Thanks, any help is much appriciated.

    Read the article

  • Improving TCP performance over a gigabit network lots of connections and high traffic for storage and streaming services

    - by Linux Guy
    I have two servers, Both servers hardware Specification are Processor : Dual Processor RAM : over 128 G.B Hard disk : SSD Hard disk Outging Traffic bandwidth : 3 Gbps network cards speed : 10 Gbps Server A : for Encoding videos Server B : for storage videos andstream videos over web interface like youtube The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos Both servers in same network , when i do ping from Server A to Server B i got high time latency above 1.0ms , the time range time=52.7 ms to time=215.7 ms - This is the output of iftop utility 353Mb 707Mb 1.04Gb 1.38Gb 1.73Gb mqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqq server.example.com => ip.address 6.36Mb 4.31Mb 1.66Mb <= 158Kb 94.8Kb 35.1Kb server.example.com => ip.address 1.23Mb 4.28Mb 1.12Mb <= 17.1Kb 83.5Kb 21.9Kb server.example.com => ip.address 395Kb 3.89Mb 1.07Mb <= 6.09Kb 109Kb 28.6Kb server.example.com => ip.address 4.55Mb 3.83Mb 1.04Mb <= 55.6Kb 45.4Kb 13.0Kb server.example.com => ip.address 649Kb 3.38Mb 1.47Mb <= 9.00Kb 38.7Kb 16.7Kb server.example.com => ip.address 5.00Mb 3.32Mb 1.80Mb <= 65.7Kb 55.1Kb 29.4Kb server.example.com => ip.address 387Kb 3.13Mb 1.06Mb <= 18.4Kb 39.9Kb 15.0Kb server.example.com => ip.address 3.27Mb 3.11Mb 1.01Mb <= 81.2Kb 64.5Kb 20.9Kb server.example.com => ip.address 1.75Mb 3.08Mb 2.72Mb <= 16.6Kb 35.6Kb 32.5Kb server.example.com => ip.address 1.75Mb 2.90Mb 2.79Mb <= 22.4Kb 32.6Kb 35.6Kb server.example.com => ip.address 3.03Mb 2.78Mb 1.82Mb <= 26.6Kb 27.4Kb 20.2Kb server.example.com => ip.address 2.26Mb 2.66Mb 1.36Mb <= 51.7Kb 49.1Kb 24.4Kb server.example.com => ip.address 586Kb 2.50Mb 1.03Mb <= 4.17Kb 26.1Kb 10.7Kb server.example.com => ip.address 2.42Mb 2.49Mb 2.44Mb <= 31.6Kb 29.7Kb 29.9Kb server.example.com => ip.address 2.41Mb 2.46Mb 2.41Mb <= 26.4Kb 24.5Kb 23.8Kb server.example.com => ip.address 2.37Mb 2.39Mb 2.40Mb <= 28.9Kb 27.0Kb 28.5Kb server.example.com => ip.address 525Kb 2.20Mb 1.05Mb <= 7.03Kb 26.0Kb 12.8Kb qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq TX: cum: 102GB peak: 1.65Gb rates: 1.46Gb 1.44Gb 1.48Gb RX: 1.31GB 24.3Mb 19.5Mb 18.9Mb 20.0Mb TOTAL: 103GB 1.67Gb 1.48Gb 1.46Gb 1.50Gb I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.2 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.2, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.1 port 38895 connected with 0.0.0.2 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes ifconfig server A eth0 Link encap:Ethernet HWaddr 00:25:90:ED:9E:AA inet addr:0.0.0.1 Bcast:0.0.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1202795665 errors:0 dropped:64334 overruns:0 frame:0 TX packets:2313161968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:893413096188 (832.0 GiB) TX bytes:3360949570454 (3.0 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:2207544 errors:0 dropped:0 overruns:0 frame:0 TX packets:2207544 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:247769175 (236.2 MiB) TX bytes:247769175 (236.2 MiB) ifconfig Server B eth2 Link encap:Ethernet HWaddr 00:25:90:82:C4:FE inet addr:0.0.0.2 Bcast:0.0.0.2 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:39973046980 errors:0 dropped:1828387600 overruns:0 frame:0 TX packets:69618752480 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3013976063688 (2.7 TiB) TX bytes:102250230803933 (92.9 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:1049495 errors:0 dropped:0 overruns:0 frame:0 TX packets:1049495 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:129012422 (123.0 MiB) TX bytes:129012422 (123.0 MiB) Netstat -i on Server B # netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth2 9000 0 42098629968 0 2131223717 0 73698797854 0 0 0 BMRU lo 65536 0 1077908 0 0 0 1077908 0 0 0 LRU I Turn up send/receive buffers on the network card to 2048 and problem still persist I increase the MTU for server A and problem still persist and i increase the MTU for server B for better connectivity and transfer speed but it couldn't transfer at all The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service in server B the transfer in server A at full speed, after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • Getting started with Oracle Database In-Memory Part III - Querying The IM Column Store

    - by Maria Colgan
    In my previous blog posts, I described how to install, enable, and populate the In-Memory column store (IM column store). This weeks post focuses on how data is accessed within the IM column store. Let’s take a simple query “What is the most expensive air-mail order we have received to date?” SELECT Max(lo_ordtotalprice) most_expensive_order FROM lineorderWHERE  lo_shipmode = 5; The LINEORDER table has been populated into the IM column store and since we have no alternative access paths (indexes or views) the execution plan for this query is a full table scan of the LINEORDER table. You will notice that the execution plan has a new set of keywords “IN MEMORY" in the access method description in the Operation column. These keywords indicate that the LINEORDER table has been marked for INMEMORY and we may use the IM column store in this query. What do I mean by “may use”? There are a small number of cases were we won’t use the IM column store even though the object has been marked INMEMORY. This is similar to how the keyword STORAGE is used on Exadata environments. You can confirm that the IM column store was actually used by examining the session level statistics, but more on that later. For now let's focus on how the data is accessed in the IM column store and why it’s faster to access the data in the new column format, for analytical queries, rather than the buffer cache. There are four main reasons why accessing the data in the IM column store is more efficient. 1. Access only the column data needed The IM column store only has to scan two columns – lo_shipmode and lo_ordtotalprice – to execute this query while the traditional row store or buffer cache has to scan all of the columns in each row of the LINEORDER table until it reaches both the lo_shipmode and the lo_ordtotalprice column. 2. Scan and filter data in it's compressed format When data is populated into the IM column it is automatically compressed using a new set of compression algorithms that allow WHERE clause predicates to be applied against the compressed formats. This means the volume of data scanned in the IM column store for our query will be far less than the same query in the buffer cache where it will scan the data in its uncompressed form, which could be 20X larger. 3. Prune out any unnecessary data within each column The fastest read you can execute is the read you don’t do. In the IM column store a further reduction in the amount of data accessed is possible due to the In-Memory Storage Indexes(IM storage indexes) that are automatically created and maintained on each of the columns in the IM column store. IM storage indexes allow data pruning to occur based on the filter predicates supplied in a SQL statement. An IM storage index keeps track of minimum and maximum values for each column in each of the In-Memory Compression Unit (IMCU). In our query the WHERE clause predicate is on the lo_shipmode column. The IM storage index on the lo_shipdate column is examined to determine if our specified column value 5 exist in any IMCU by comparing the value 5 to the minimum and maximum values maintained in the Storage Index. If the value 5 is outside the minimum and maximum range for an IMCU, the scan of that IMCU is avoided. For the IMCUs where the value 5 does fall within the min, max range, an additional level of data pruning is possible via the metadata dictionary created when dictionary-based compression is used on IMCU. The dictionary contains a list of the unique column values within the IMCU. Since we have an equality predicate we can easily determine if 5 is one of the distinct column values or not. The combination of the IM storage index and dictionary based pruning, enables us to only scan the necessary IMCUs. 4. Use SIMD to apply filter predicates For the IMCU that need to be scanned Oracle takes advantage of SIMD vector processing (Single Instruction processing Multiple Data values). Instead of evaluating each entry in the column one at a time, SIMD vector processing allows a set of column values to be evaluated together in a single CPU instruction. The column format used in the IM column store has been specifically designed to maximize the number of column entries that can be loaded into the vector registers on the CPU and evaluated in a single CPU instruction. SIMD vector processing enables the Oracle Database In-Memory to scan billion of rows per second per core versus the millions of rows per second per core scan rate that can be achieved in the buffer cache. I mentioned earlier in this post that in order to confirm the IM column store was used; we need to examine the session level statistics. You can monitor the session level statistics by querying the performance views v$mystat and v$statname. All of the statistics related to the In-Memory Column Store begin with IM. You can see the full list of these statistics by typing: display_name format a30 SELECT display_name FROM v$statname WHERE  display_name LIKE 'IM%'; If we check the session statistics after we execute our query the results would be as follow; SELECT Max(lo_ordtotalprice) most_expensive_order FROM lineorderWHERE lo_shipmode = 5; SELECT display_name FROM v$statname WHERE  display_name IN ('IM scan CUs columns accessed',                        'IM scan segments minmax eligible',                        'IM scan CUs pruned'); As you can see, only 2 IMCUs were accessed during the scan as the majority of the IMCUs (44) in the LINEORDER table were pruned out thanks to the storage index on the lo_shipmode column. In next weeks post I will describe how you can control which queries use the IM column store and which don't. +Maria Colgan

    Read the article

  • Computer Networks UNISA - Chap 14 &ndash; Insuring Integrity &amp; Availability

    - by MarkPearl
    After reading this section you should be able to Identify the characteristics of a network that keep data safe from loss or damage Protect an enterprise-wide network from viruses Explain network and system level fault tolerance techniques Discuss issues related to network backup and recovery strategies Describe the components of a useful disaster recovery plan and the options for disaster contingencies What are integrity and availability? Integrity – the soundness of a networks programs, data, services, devices, and connections Availability – How consistently and reliably a file or system can be accessed by authorized personnel A number of phenomena can compromise both integrity and availability including… security breaches natural disasters malicious intruders power flaws human error users etc Although you cannot predict every type of vulnerability, you can take measures to guard against the most damaging events. The following are some guidelines… Allow only network administrators to create or modify NOS and application system users. Monitor the network for unauthorized access or changes Record authorized system changes in a change management system’ Install redundant components Perform regular health checks on the network Check system performance, error logs, and the system log book regularly Keep backups Implement and enforce security and disaster recovery policies These are just some of the basics… Malware Malware refers to any program or piece of code designed to intrude upon or harm a system or its resources. Types of Malware… Boot sector viruses Macro viruses File infector viruses Worms Trojan Horse Network Viruses Bots Malware characteristics Some common characteristics of Malware include… Encryption Stealth Polymorphism Time dependence Malware Protection There are various tools available to protect you from malware called anti-malware software. These monitor your system for indications that a program is performing potential malware operations. A number of techniques are used to detect malware including… Signature Scanning Integrity Checking Monitoring unexpected file changes or virus like behaviours It is important to decide where anti-malware tools will be installed and find a balance between performance and protection. There are several general purpose malware policies that can be implemented to protect your network including… Every compute in an organization should be equipped with malware detection and cleaning software that regularly runs Users should not be allowed to alter or disable the anti-malware software Users should know what to do in case the anti-malware program detects a malware virus Users should be prohibited from installing any unauthorized software on their systems System wide alerts should be issued to network users notifying them if a serious malware virus has been detected. Fault Tolerance Besides guarding against malware, another key factor in maintaining the availability and integrity of data is fault tolerance. Fault tolerance is the ability for a system to continue performing despite an unexpected hardware or software malfunction. Fault tolerance can be realized in varying degrees, the optimal level of fault tolerance for a system depends on how critical its services and files are to productivity. Generally the more fault tolerant the system, the more expensive it is. The following describe some of the areas that need to be considered for fault tolerance. Environment (Temperature and humidity) Power Topology and Connectivity Servers Storage Power Typical power flaws include Surges – a brief increase in voltage due to lightening strikes, solar flares or some idiot at City Power Noise – Fluctuation in voltage levels caused by other devices on the network or electromagnetic interference Brownout – A sag in voltage for just a moment Blackout – A complete power loss The are various alternate power sources to consider including UPS’s and Generators. UPS’s are found in two categories… Standby UPS – provides continuous power when mains goes down (brief period of switching over) Online UPS – is online all the time and the device receives power from the UPS all the time (the UPS is charged continuously) Servers There are various techniques for fault tolerance with servers. Server mirroring is an option where one device or component duplicates the activities of another. It is generally an expensive process. Clustering is a fault tolerance technique that links multiple servers together to appear as a single server. They share processing and storage responsibilities and if one unit in the cluster goes down, another unit can be brought in to replace it. Storage There are various techniques available including the following… RAID Arrays NAS (Storage (Network Attached Storage) SANs (Storage Area Networks) Data Backup A backup is a copy of data or program files created for archiving or safekeeping. Many different options for backups exist with various media including… These vary in cost and speed. Optical Media Tape Backup External Disk Drives Network Backups Backup Strategy After selecting the appropriate tool for performing your servers backup, devise a backup strategy to guide you through performing reliable backups that provide maximum data protection. Questions that should be answered include… What data must be backed up At what time of day or night will the backups occur How will you verify the accuracy of the backups Where and for how long will backup media be stored Who will take responsibility for ensuring that backups occurred How long will you save backups Where will backup and recovery documentation be stored Different backup methods provide varying levels of certainty and corresponding labour cost. There are also different ways to determine which files should be backed up including… Full backup – all data on all servers is copied to storage media Incremental backup – Only data that has changed since the last full or incremental backup is copied to a storage medium Differential backup – Only data that has changed since the last backup is coped to a storage medium Disaster Recovery Disaster recovery is the process of restoring your critical functionality and data after an enterprise wide outage has occurred. A disaster recovery plan is for extreme scenarios (i.e. fire, line fault, etc). A cold site is a place were the computers, devices, and connectivity necessary to rebuild a network exist but they are not appropriately configured. A warm site is a place where the computers, devices, and connectivity necessary to rebuild a network exists with some appropriately configured devices. A hot site is a place where the computers, devices, and connectivity necessary to rebuild a network exists and all are appropriately configured.

    Read the article

  • ESXi 4.1 host not recognising existing VMFS datastore

    - by Graeme Donaldson
    Existing setup: host1 and host2, ESX 4.0, 2 HBAs each. lun1 and lun2, 2 LUNs belonging to the same RAID set (my terminology might be sketchy here). This has been working just fine all along. I added host3, ESXi 4.1, 2 HBAs. If I view Configuration / Storage Adapters, I can see that both HBAs see both LUNs, but if I view Configuration / Storage, I only see 1 datastore. host1/2 can see both LUNs and I have VMs running on both too. I have rescanned, refreshed and even rebooted, but host3 refuses to acknowledge 1 of the datastores. Does anyone know what's going on? Update: I re-installed the host with ESX (not i) 4.0, same version as the existing hosts and it's still not recognising the vmfs. I think I'm going to SVmotion everything off that datastore then format it. Update2: I've created the LUN from scratch and the problem gets even weirder. I've presented the LUN to all 3 hosts, and I can see the LUN in the vSphere client's Configuration / Storage Adapters section on all 3 hosts. If I create a datastore on the LUN via the Configuration / Storage section on host1, it works fine and I can create an empty folder via datastore browser, but the datastore is not seen by the host2 and host3. I can use the Add Storage wizard on host2 and it will see the LUN. At this point the "VMFS Label" column has the label I gave with "(head)" appended. If I try the Add Storage wizard's "Keep the existing signature" option, it fails with an error "Cannot change the host configuration." and a dialog box that says 'Call "HostStorageSystem.ResolveMultipleUnresolvedVmfsVolumes" for object "storageSystem-17" on vCenter Server "vcenter.company.local" failed.' If I try the Add Storage wizard's "Assign a new signature" option on host2, it will complete and the VMFS label will have "snap-(hexnumber)-" prepended. At this point its also visible on host3, but not host1. I have a similar setup in a different datacenter which didn't give me all this trouble.

    Read the article

  • ESXi 4.1 host not recognising existing VMFS datastore

    - by ThatGraemeGuy
    Existing setup: host1 and host2, ESX 4.0, 2 HBAs each. lun1 and lun2, 2 LUNs belonging to the same RAID set (my terminology might be sketchy here). This has been working just fine all along. I added host3, ESXi 4.1, 2 HBAs. If I view Configuration / Storage Adapters, I can see that both HBAs see both LUNs, but if I view Configuration / Storage, I only see 1 datastore. host1/2 can see both LUNs and I have VMs running on both too. I have rescanned, refreshed and even rebooted, but host3 refuses to acknowledge 1 of the datastores. Does anyone know what's going on? Update: I re-installed the host with ESX (not i) 4.0, same version as the existing hosts and it's still not recognising the vmfs. I think I'm going to SVmotion everything off that datastore then format it. Update2: I've created the LUN from scratch and the problem gets even weirder. I've presented the LUN to all 3 hosts, and I can see the LUN in the vSphere client's Configuration / Storage Adapters section on all 3 hosts. If I create a datastore on the LUN via the Configuration / Storage section on host1, it works fine and I can create an empty folder via datastore browser, but the datastore is not seen by the host2 and host3. I can use the Add Storage wizard on host2 and it will see the LUN. At this point the "VMFS Label" column has the label I gave with "(head)" appended. If I try the Add Storage wizard's "Keep the existing signature" option, it fails with an error "Cannot change the host configuration." and a dialog box that says 'Call "HostStorageSystem.ResolveMultipleUnresolvedVmfsVolumes" for object "storageSystem-17" on vCenter Server "vcenter.company.local" failed.' If I try the Add Storage wizard's "Assign a new signature" option on host2, it will complete and the VMFS label will have "snap-(hexnumber)-" prepended. At this point its also visible on host3, but not host1. I have a similar setup in a different datacenter which didn't give me all this trouble.

    Read the article

  • More information wanted on error: CREATE ASSEMBLY for assembly failed because assembly failed verif

    - by turnip.cyberveggie
    I have a small application that uses SQL Server 2005 Express with CLR stored procedures. It has been successfully installed and runs on many computers running XP and Vista. To create the assembly the following SQL is executed (names changed to protect the innocent): CREATE ASSEMBLY myAssemblyName FROM 'c:\pathtoAssembly\myAssembly.dll' On one computer (a test machine that reflects other computers targeted for installation) that is running Vista and has some very aggressive security policy restrictions I receive the following error: << Start Error Message Msg 6218, Level 16, State 2, Server domain\servername, Line 2 CREATE ASSEMBLY for assembly 'myAssembly' failed because assembly 'myAssembly' failed verification. Check if the referenced assemblies are up-to-date and trusted (for external_access or unsafe) to execute in the database. CLR Verifier error messages if any will follow this message [ : myProcSupport.Axis::Proc1][mdToken=0x6000004] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc2][mdToken=0x6000005] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc3][mdToken=0x6000006] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::.ctor][mdToken=0x600000a] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc4][mdToken=0x6000001] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc5][mdToken=0x6000002] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc6][mdToken=0x6000007] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc7][mdToken=0x6000008] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc8][mdToken=0x6000009] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc8][mdToken=0x600000b] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation. [ : myProcSupport.Axis::Proc9][mdToken=0x600000c] [HRESULT 0x8007000E] - Not enough storage is available to complete this operation.... << End Error Message The C# DLL is defined as “Safe” as it only uses data contained in the database. The DLL is not normally signed, but I provided a signed version to test and received the same results. The installation is being done by someone else, and I don’t have access to the box, but they are executing scripts that I provided and work on other computers. I have tried to find information about this error beyond what the results of the script provide, but I haven’t found anything helpful. The person executing the script to create the assembly is logged in with an Admin account, is running CMD as admin, is connecting to the DB via Windows Authentication, has been added to the dbo_owner role, and added to the server role SysAdmin with the hopes that it is a permissions issue. This hasn't changed anything. Do I need to configure SQL Server 2005 Express differently for this environment? Is this error logged anywhere other than just the output from SQLCMD? What could cause this error? Could Vista security policies cause this? I don’t have access to the computer (the customer is doing the testing) so I can’t examine the box myself. TIA

    Read the article

  • Can't make AWUS036H work in Ubuntu 12.10

    - by sfrj
    I am using 64 bit Ubuntu 12.10. This is my kernel version: Linux 3.5.0-19-generic #30-Ubuntu SMP Tue Nov 13 17:48:01 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux My wireless card is an AWUSU36H The first thing I do to install the driver is copy the driver from the CD to the Downloads folder. cd /media/me/AWUS036H/Drivers/RTL8187L/Unix (Linux)/Linux driver for kernel 2.6.X$ cp rtl8187_linux_26.1025.0328.2007.tar.gz ~/Downloads/ Then I extract the tar tar xvfz rtl8187_linux_26.1025.0328.2007.tar.gz I navigate into the extracted folder, and I try to follow the instructions in the Readme.txt cd rtl8187_linux_26.1025.0328.2007 This are the contents of the folder: drv.tar.gz makedrv stack.tar.gz wlan0rmv ieee80211 ReadMe.txt wlan0dhcp wlan0up ifcfg-wlan0 rtl8187 wlan0down wpa_supplicant-0.4.9 This is what the Readme.txt says: Release Date: 2006-02-09, ver 1.2^M RTL8187 Linux driver version 1.2^M ^M --This driver supports RealTek RTL8187 Wireless LAN driver for ^M Fedora Core 2/3/4/5, Debian 3.1, Mandrake 10.2/Mandriva 2006, ^M SUSE 9.3/10.1/10.2, Gentoo 3.1, etc.^M - Support Client mode for either infrastructure or adhoc mode^M - Support WEP and WPAPSK connection^M ^M < Component >^M The driver is composed of several parts:^M 1. Module source code^M stack.tar.gz^M drv.tar.gz^M ^M 2. Script ot build the modules^M makedrv^M ^M 3. Script to load/unload modules^M wlan0up^M wlan0down ^M ^M 4. Script and configuration for DHCP^M "ReadMe.txt" [readonly] 140 lines, 4590 characters So what I do know is extract both of the compressed files: sudo tar xvfz drv.tar.gz sudo tar xvfz stack.tar.gz This 2 commands will add some data to the folders ieee80211 and rtl8187 At this point I get lost, and I don't know what to do. If I go in each of this 2 folders and I run the sudo make command then I get errors like this one: sudo makemake -C /lib/modules/3.5.0-19-generic/build M=/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187 modules make[1]: Entering directory `/usr/src/linux-headers-3.5.0-19-generic' CC [M] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.c:64:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187.h:29:26: fatal error: linux/config.h: No such file or directory compilation terminated. make[2]: *** [/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o] Error 1 make[1]: *** [_module_/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.5.0-19-generic' make: *** [modules] Error 2 If I try to run any of the script ./makedrv that the instructions describe, then I also get an error: ~/Downloads/rtl8187_linux_26.1025.0328.2007$ sudo ./makedrv [sudo] password for me: ieee80211/ ieee80211/license ieee80211/ieee80211_crypt.c ieee80211/ieee80211_tx.c ieee80211/ieee80211_softmac.c ieee80211/ieee80211_softmac_wx.c ieee80211/ieee80211_module.c ieee80211/ieee80211_crypt_ccmp.c ieee80211/ieee80211_rx.c ieee80211/tags ieee80211/ieee80211_crypt_tkip.c ieee80211/Makefile ieee80211/readme ieee80211/.tmp_versions/ ieee80211/.tmp_versions/ieee80211-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt_wep-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt_tkip-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt_ccmp-rtl.mod ieee80211/ieee80211_crypt_wep.c ieee80211/ieee80211.h ieee80211/ieee80211_wx.c ieee80211/ieee80211_crypt.h rtl8187/ rtl8187/license rtl8187/r8180_rtl8225z2.c rtl8187/r8180_rtl8225.h rtl8187/r8187_led.c rtl8187/r8180_93cx6.h rtl8187/r8180_wx.h rtl8187/r8180_hw.h rtl8187/copying rtl8187/r8187_led.h rtl8187/r8180_pm.h rtl8187/tags rtl8187/r8187.h rtl8187/Makefile rtl8187/r8180_rtl8225.c rtl8187/readme rtl8187/install rtl8187/.tmp_versions/ rtl8187/.tmp_versions/r8187.mod rtl8187/changes rtl8187/r8180_wx.c rtl8187/r8180_pm.c rtl8187/r8187_core.c rtl8187/r8180_93cx6.c rtl8187/authors rtl8187/ieee80211.h rtl8187/ieee80211_crypt.h rm -f *.mod.c *.mod *.o .*.cmd *.ko *~ rm -rf /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/tmp make -C /lib/modules/3.5.0-19-generic/build M=/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211 modules make[1]: Entering directory `/usr/src/linux-headers-3.5.0-19-generic' CC [M] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.o In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:1019:24: error: field ‘ps_task’ has incomplete type /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_scan_wq’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:421:2: warning: passing argument 2 of ‘queue_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:371:12: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_stop_scan’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:495:3: warning: passing argument 1 of ‘cancel_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:410:20: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_associate_abort’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:915:2: warning: passing argument 2 of ‘queue_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:371:12: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_rx_frame_softmac’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:1527:3: error: implicit declaration of function ‘tasklet_schedule’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_stop_protocol_rtl’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2120:2: warning: passing argument 1 of ‘cancel_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:410:20: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_init’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2229:78: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2229:2: error: ‘INIT_WORK’ undeclared (first use in this function) /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2229:2: note: each undeclared identifier is reported only once for each function it appears in /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2230:88: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2231:94: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2232:96: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2233:82: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2234:82: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2244:2: error: implicit declaration of function ‘tasklet_init’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_free’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2255:2: warning: passing argument 1 of ‘cancel_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:410:20: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_wpa_set_encryption’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2489:3: error: implicit declaration of function ‘request_module’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2518:3: error: implicit declaration of function ‘try_module_get’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: At top level: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2663:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2663:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2663:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2664:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2664:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2664:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2665:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2665:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2665:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2666:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2666:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2666:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2667:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2667:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2667:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2668:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2668:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2668:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2669:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2669:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2669:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2670:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2670:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2670:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2671:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2671:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2671:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2672:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2672:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2672:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2673:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2673:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2673:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2674:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2674:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2674:1: warning: parameter names (without types) in function declaration [enabled by default] In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:1212:37: warning: ‘netdev_priv’ is static but used in inline function ‘ieee80211_priv’ which is not static [enabled by default] cc1: some warnings being treated as errors make[2]: *** [/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.o] Error 1 make[1]: *** [_module_/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.5.0-19-generic' make: *** [modules] Error 2 rm -f *.mod.c *.mod *.o .*.cmd *.ko *~ rm -rf /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/tmp make -C /lib/modules/3.5.0-19-generic/build M=/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187 modules make[1]: Entering directory `/usr/src/linux-headers-3.5.0-19-generic' CC [M] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.c:64:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187.h:29:26: fatal error: linux/config.h: No such file or directory compilation terminated. make[2]: *** [/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o] Error 1 make[1]: *** [_module_/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.5.0-19-generic' make: *** [modules] Error 2 Can somebody give me a hand finding out what I need to do to make my wifi card work? Update This is the output of the lsusb command lsusb Bus 003 Device 002: ID 147e:1000 Upek Biometric Touchchip/Touchstrip Fingerprint Sensor Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub

    Read the article

  • django app using amazon aws s3 storage in stead of DB?

    - by farble1670
    new to python here so bear with me ... i'm looking at django for a rapid prototype to a photo sharing app with an amazon aws s3 storage back end. however, as far as i can tell, django is tailored toward the typical database MVC type of pattern. is there a way to for example provide a custom django model implementation that talks to s3 in stead of a DB? a custom DB engine? would either of these be practical, or am i looking in the wrong direction? thanks.

    Read the article

  • How can I remove .NET isolated storage setting folders during WiX uninstallation?

    - by Luke
    I would like to remove the isolated storage folders that are created by a .NET application when using My.Settings etc. The setting files are stored in a location like C:\Users\%Username%\AppData\Roaming\App\App.exe_Url_r0q1rvlnrqsgjkcosowa0vckbjarici4 As per this question StackOverflow: Removing files when uninstalling Wix I can uninstall a folder using: <Directory Id="AppDataFolder" Name="AppDataFolder"> <Directory Id="MyAppFolder" Name="My"> <Component Id="MyAppFolder" Guid="YOURGUID-7A34-4085-A8B0-8B7051905B24"> <CreateFolder /> <RemoveFile Id="PurgeAppFolder" Name="*.*" On="uninstall" /> </Component> </Directory> </Directory> <!-- LocalAppDataFolder--> This doesn't support sub-folders etc. Is the only option a custom .NET action or is there a more simple approach for removing these .NET generated setting folders?

    Read the article

  • Opening Office 2007 Documents from in memory storage - How?

    - by John S
    Hi there, I'm a C++ developer wrestling with updating an application that had made extensive use of the IStorage interface to open pre-Office 2007 documents from in-memory storage (via ILockBytes). If you are still following me so far, you probably know that the new Office Document formats are incompatible with IStorage containers. The application I'm trying to update, relied upon the IPersistStorage interface that all Office applications have, and the code as written calls the load method of IPersistStorage to read in a document from IStorage interface. So the question is.... What kind of COM interfaces are available to me to read in, from an in memory container, an Office 2007 document? John "S"

    Read the article

  • I want to use the fleximage gem and s3 for storage, but don't want dev/qa/test env's to use s3

    - by Kevin Bedell
    I have a rails app that I'm going to host on engineyard and want to store image files on s3. But I don't know if I want all developer machines to beusing s3 for storage of all our test and dev images. Maybe it's not an issue -- but it seems like a waste to have everyone storing all our images in s3. I've heard of some ppl who store images on s3 'hacking' dev environments to store images locally on the file system -- and then using s3 in prod only. What are other people doing?

    Read the article

  • What mail storage should I choose for our web application; IMAP, key-valud store, rdbms, ...

    - by tvrtko
    I have to store e-mail messages for use with our application. I have "metadata" for all messages inside a relational database, but I don't feel comfortable keeping message content (gigabytes and terabytes of email data) inside a database. I'm currently using IMAP as a storage, but I have my doubts if I choose correctly. First of all there is a problem of uidvalidity and how to keep a permanent reference to message inside IMAP. Second, I'm not sure if this is the most robust solution in terms of backup/restore strategies, corruption of store, replication ... Positive side is that I can query IMAP using the headers because the data is mostly indexed. I don't know if key-value stores are a better approach (Casandra, Tokyo cabinet, redis). How they handle storing 1KB and 50MB of data. How they prevent corruption and when corruption or device failure happens how can I repair the store.

    Read the article

  • What is a valid and reasonable alternative to a massive storage approach?

    - by Backo
    I am using Ruby on Rails 3.2.2 and MySQL. After my previous question on "how to handle massive storage of records in database for user authorization purposes", since related answers (on how to solve the issue or how to accomplish to that I am looking for) aren't sufficiently detailed or require to much resources (at least for me), I would like to know what are valid and reasonable alternatives to that approach. In few words, this question could be phrase as: how to handle "complex" (at level of SQL querying) user authorizations when you have to fetch "authorized" records? That is, for example, how to retrieve records when you would use code like the following (the following code would be used mostly in index controller actions): Article.readable_by_user(@current_user) # => Returns all articles readable by the current user.

    Read the article

  • Which file types are worth compressing (zipping) for remote storage? For which of them the compresse

    - by user193655
    I am storing documents in sql server in varbinary(max) fileds, I use filestream optionally when a user has: (DB_Size + Docs_Size) ~> 0.8 * ExpressEdition_Max_DB_Size I am currently zipping all the files, anyway this is done because the Document Read/Write work was developed 10 years ago where Storage was more expensive than now. Many files when zipped are almost as big as the original (a zipped pdf is about 95% of original size). And anyway unzipping has some overhead, that becomes twice when I need also to "Check-in"/Update the file because I need to zip it. So I was thinking of giving to the users the option to choose whether the file type will be zipped or not by providing some meaningful default values. For my experience I would impose the following rules: 1) zip by default: txt, bmp, rtf 2) do not zip by default: jpg, jpeg, Microsoft Office files, Open Office files, png, tif, tiff Could you suggest other file types chosen among the most common or comment on the ones I listed here?

    Read the article

  • Offsite data storage for simple app, or a similar supported persistence mechanism?

    - by jdk
    Question Is there a usable facebook entry point to the Data Storage API that facebook lists on their app admin page for developers, or should I consider an alternate mechanism? What alternative mechanisms exist to simply persist my information offsite (away from my server app) without stuffing it into a cookie that's prone to expire? ... Background The facebook Data Store Admin tool is made available in a facebook App's Settings as seen here: (continue reading below) However when I visit the DataStoreAdmin link nothing works (i.e. clicking the buttons to define the data store types and objects does nothing - I have tried different browsers). The Wiki page for Data Store API hasn't been updated recently and the second last update says the beta Data Store was taken offline. It seems odd the link would be readily available and highly visible at the top of the App configuration area if indeed it's defunct. I was hoping some kind of key/value pair solution to remove the data calls from my own server.

    Read the article

  • How to implement collection with covariance when delegating to another collection for storage?

    - by memelet
    I'm trying to implement a type of SortedMap with extended semantics. I'm trying to delegate to SortedMap as the storage but can't get around the variance constraints: class IntervalMap[A, +B](implicit val ordering: Ordering[A]) //extends ... { var underlying = SortedMap.empty[A, List[B]] } Here is the error I get. I understand why I get the error (I understand variance). What I don't get is how to implement this type of delegation. And yes, the covariance on B is required. error: covariant type B occurs in contravariant position in type scala.collection.immutable.SortedMap[A,List[B]] of parameter of setter underlying_=

    Read the article

  • DNS CNAME - SSL-certificate issue.

    - by Phoibe
    Hey, I have obtained an SSL certificate by Thawte for domain.com Now my infrastructure changed due to heavy load I have mx.domain.com as SMTP relay storage.domain.com as Mail-Storage and domain.com pointing at Web-Server Every server is hosted on another dedicated/virtual server with individual IP. I do not want to put the Web-Server on the Mail-Storage for security reasons but I do want to use my SSL-Certificate for the Mail-Storage(POP3S/IMAPS). Is that possible or how do I solve that issue?

    Read the article

  • UDISKS instead of HAL

    - by MeJ
    Does anybody have some expirence with udisks, because HAL won't be longer supported on the most linux distribution, so I am thinking of to use udisks for UDI in $(hal-find-by-property --key storage.bus --string usb) do HAL_TMP=`hal-get-property --udi $UDI --key storage.removable.media_available` if [ "$HAL_TMP" = "true" ]; then HAL_DEV=$(hal-get-property --udi $UDI --key block.device) HAL_SIZE=$(hal-get-property --udi $UDI --key storage.removable.media_size) HAL_TYPE=$(hal-get-property --udi $UDI --key storage.drive_type) How do I have to adapt the above mentioned commands but use udisks instead of hal Thanks!

    Read the article

  • Why do compiled Haskell libraries see invalid static FFI storage?

    - by John Millikin
    I am using GHC 6.12.1, in Ubuntu 10.04 When I try to use the FFI syntax for static storage, only modules running in interpreted mode (ie GHCI) work properly. Compiled modules have invalid pointers, and do not work. I'd like to know whether anybody can reproduce the problem, whether this an error in my code or GHC, and (if the latter) whether it's a known issue. Given the following three modules: -- A.hs {-# LANGUAGE ForeignFunctionInterface #-} module A where import Foreign import Foreign.C foreign import ccall "&sys_siglist" siglist_a :: Ptr CString -- -- B.hs {-# LANGUAGE ForeignFunctionInterface #-} module B where import Foreign import Foreign.C foreign import ccall "&sys_siglist" siglist_b :: Ptr CString -- -- Main.hs {-# LANGUAGE ForeignFunctionInterface #-} module Main where import Foreign import Foreign.C import A import B foreign import ccall "&sys_siglist" siglist_main :: Ptr CString main = do putStrLn $ "siglist_a = " ++ show siglist_a putStrLn $ "siglist_b = " ++ show siglist_b putStrLn $ "siglist_main = " ++ show siglist_main peekSiglist "a " siglist_a peekSiglist "b " siglist_b peekSiglist "main" siglist_main peekSiglist name siglist = do ptr <- peekElemOff siglist 2 str <- maybePeek peekCString ptr putStrLn $ "siglist_" ++ name ++ "[2] = " ++ show str I would expect something like this output, where all pointer values identical and valid: $ runhaskell Main.hs siglist_a = 0x00007f53a948fe00 siglist_b = 0x00007f53a948fe00 siglist_main = 0x00007f53a948fe00 siglist_a [2] = Just "Interrupt" siglist_b [2] = Just "Interrupt" siglist_main[2] = Just "Interrupt" However, if I compile A.hs (with ghc -c A.hs), then the output changes to: $ runhaskell Main.hs siglist_a = 0x0000000040378918 siglist_b = 0x00007fe7c029ce00 siglist_main = 0x00007fe7c029ce00 siglist_a [2] = Nothing siglist_b [2] = Just "Interrupt" siglist_main[2] = Just "Interrupt"

    Read the article

  • Whether to put method code in a VB.Net data storage class, or put it in a separate class?

    - by Alan K
    TLDR summary: (a) Should I include (lengthy) method code in classes which may spawn multiple objects at runtime, (b) does doing so cause memory usage bloat, (c) if so should I "outsource" the code to a class that is loaded only once and have the class methods call that, or alternatively (d) does the code get loaded only once with the object definition anyway and I'm worrying about nothing? ........ I don't know whether there's a good answer to this but if there is I haven't found it yet by searching in the usual places. In my VB.Net (2010 if it matters) WinForms project I have about a dozen or so class objects in an object model. Some of these are pretty simple and do little more than act as data storage repositories. The ones further up the object model, however, have an increasing number of methods. There can be a significant number of higher level objects in use though the exact number will be runtime dependent so I can't be more precise than that. As I was writing the method code for one of the top level ones I noticed that it was starting to get quite lengthy. Memory optimisation is something of a lost art given how much memory the average PC has these days but I don't want to make my application a resource hog. So my questions for anyone who knows .Net way better than I do (of which there will be many) are: Is the code loaded into memory with each instance of the class that's created? Alternatively is it loaded only once with the definition of the class, and all derived objects just refer to that definition? (I'm not really sure how that could be possible given that, for example, event handlers can be assigned dynamically, but no harm asking.) If the answer to the first one is yes, would it be more efficient to write the code in a "utility" object which is loaded only once and called from the real class' methods? Any thoughts appreciated.

    Read the article

  • What is the best way to create a running integer id on the AppEngine data storage?

    - by Freed
    For various reasons, I need a unique running integer id for my entities stored on the Google AppEngine. The automatically generated key sort of has this behaviour, but it doesn't start from 1 (or 0) and doesn't guarantee that the generated integer part will come from a continuous sequence. What would be the best way to efficiently implement this on AppEngine? Is there any support from the storage system? To add to the complexity, I might need to do this over entities from different entity groups, meaning I can't just get the highest id right now and save an entity with the next id in a transaction. Might memcache be the way to go..? Edit: I havn't yet implemented this, but to clarify on the memcache idea. I know memcache is unreliable, but in practice it probably won't lose data "too often" to hurt performance. Basically, I would have a memcache entry for the last used id, update it (somehow atomically) whenever I create a new entity and use that id. In the case of memcache not having a value for this entry, I'd get the highest id so far by doing a query on my entities sorted by the id and update memcache (unless someone else had already done so). The only problem I can see with this right now would be atomicity of the operation as a whole if the save of my new entity was also part of a transaction. Thoughts..?

    Read the article

< Previous Page | 89 90 91 92 93 94 95 96 97 98 99 100  | Next Page >