Search Results

Search found 4866 results on 195 pages for 'crm failure'.

Page 93/195 | < Previous Page | 89 90 91 92 93 94 95 96 97 98 99 100  | Next Page >

  • Why am I stuck at 640x480 on an Optimus hybrid-graphics system?

    - by exilada
    I have Intel HD 3000 graphics card onboard and nvidia 520 mx optimus techolonogy card. I was try to install Nvidia driver but it was failure. Now I cant use anything. Have one resolution 640x480 every media disconnected and I cant connect $ xrandr Screen 0: minimum 320 x 200, current 640 x 480, maximum 8192 x 8192 LVDS1 connected 640x480+0+0 (normal left inverted right x axis y axis) 344mm x 194mm 640x480 59.9* VGA1 disconnected (normal left inverted right x axis y axis) HDMI1 disconnected (normal left inverted right x axis y axis) DP1 disconnected (normal left inverted right x axis y axis) lspci | grep VGA 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09 ) glxinfo | grep vendor server glx vendor string: SGI client glx vendor string: Mesa Project and SGI OpenGL vendor string: Tungsten Graphics, Inc Blockquote something wrong here I guess I try to some solutions but didnt work even it cant nvidia-xconfig file after these By the way system get eror sometimes about xorg Sorry for my English thaks for help.

    Read the article

  • External hard drive failing, is backup recovery possible?

    - by backitup
    I have a Seagate Freeagent external hard drive. While I was backing it up on Windows XP my pc crashed and I received the horrifying "Delayed Write Error" when I rebooted citing "$MFT" and a few other files. I tried to unmount it, but to no avail. Now my pc just crashes when I try to access it via Windows. In Ubuntu I am able to view it through disk utility. SMART status is "DISK FAILURE IMMINENT". Fdisk doesn't work, and the SMART tests fail on "Reallocated Sector Count". Is there any way for me to rescue any of my data. I can still access the drive but as soon as I do that it crashes.

    Read the article

  • IIS to parse php in a .dll files

    - by Agony
    The .dll files ain't the dynamic link library. That's what the client side software calls for (cannot change). Its essentially a php script that should run and return specific values. However currently it simply downloads it and that results in a failure. That's what it results in on a Apache server: [Update] NewVersion=1 UpdateFileNumber=1 UpdateFile1=update1/LPServerInfo.dat ServerNumber=1 Server1=http://88.159.116.217/ here it is on IIS: 198.24.133.74:8080/update.dll?0 renaming it to php works fine for testing - it runs and returns values. I edited the MIME and set .dll to application/x-httpd-php but that doesn't seem to work in IIS. Any solutions?

    Read the article

  • Xubuntu and other Debian based distros slow

    - by William V
    I have a Compaq Presario SR1950NX desktop computer with the AMD64 3800+ processor and 1GB ram and it seems that Ubunutu, Xubuntu and Lubuntu are all laggy. Things seem to be slow such as clicking on menus and opening programs and the UI renders in peices. When using the browser the system slows down considerably. I ran the TOP command and I do notice that xorg hits 30 to 40 percent cpu when running the browsers. I have tried these distros on a spare P4 machine and it is even worse. As long as I don't have a several things open at one time I can manage to get around although sluggishly. I also notice that I can't get debian based distros to install in 64bit (crtc6 failure) only in 32bit. Can anyone tell me what is it that I might be doing wrong? I have an integrated Nvidia card and have tried several of the recommended drivers which sometimes result in no boot screen upon reboot. Thanks

    Read the article

  • How to deploy a single website to multiple physical servers.?

    - by user70122
    I want to deploy my PHP and Ajax based Dating website to multiple physical servers. Does anyone know the method. Is there possible any method to save the files and setting (and also the user input), on all of the physical server, so that the servers do the following jobs. Servers used as a network, speeding up the process giving a robust thing to the end user. Data to be stored on all the servers' hard drivers, and Every server have the internet connection from different provider, so for example a. if any of the internet providers gets down, or b. there occur any hardware or power failure, the website still runs, without a break and without any data loss. Does anyone know about some online course, or some comprehensive tutorials about this topic ?

    Read the article

  • How can I convince a project manager that there is no way to solve all the compatibility issues?

    - by SAFAD
    I have been working on this project for more than a year now, and we are close to release, the project manager wants the product to be perfect and working in every single aspect. I like that and I love working under the perfection idea, but it seems he is delaying the launch too much because of compatibility issues, he wants the product to work in every single installation, every single configuration possible, and in most cases, the product just works without issues when it's on the hands of the client. UPDATE : yes the product doesn't work properly when there are conflicts, for example, other products that don't use guidelines nor standards to load libraries (causes double library load which leads to failure), cache is another example and so on..... but we warn the clients about the conflict before purchasing and help them fixing it after purchasing I've tried to explain it by giving some examples on major products, he understands the situation, but can not believe that it is near impossible (if it is not impossible) to do what he wants. Hope it is clarified enough for the community to answer.

    Read the article

  • Unit testing multiple conditions in an IF statement

    - by bwalk2895
    I have a chunk of code that looks something like this: function bool PassesBusinessRules() { bool meetsBusinessRules = false; if (PassesBusinessRule1 && PassesBusinessRule2 && PassesBusinessRule3) { meetsBusinessRules= true; } return meetsBusinessRules; } I believe there should be four unit tests for this particular function. Three to test each of the conditions in the if statement and ensure it returns false. And another test that makes sure the function returns true. Question: Should there actually be ten unit tests instead? Nine that checks each of the possible failure paths. IE: False False False False False True False True False And so on for each possible combination. I think that is overkill, but some of the other members on my team do not. The way I look at it is if BusinessRule1 fails then it should always return false, it doesn't matter if it was checked first or last.

    Read the article

  • screen driver problem

    - by exilada
    I have Intel HD 3000 graphics card onboard and nvidia 520 mx optimus techolonogy card. I was try to install Nvidia driver but it was failure. Now I cant use anything. Have one resolution 640x480 every media disconnected and I cant connect $ xrandr Screen 0: minimum 320 x 200, current 640 x 480, maximum 8192 x 8192 LVDS1 connected 640x480+0+0 (normal left inverted right x axis y axis) 344mm x 194mm 640x480 59.9* VGA1 disconnected (normal left inverted right x axis y axis) HDMI1 disconnected (normal left inverted right x axis y axis) DP1 disconnected (normal left inverted right x axis y axis) lspci | grep VGA 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09 ) glxinfo | grep vendor server glx vendor string: SGI client glx vendor string: Mesa Project and SGI OpenGL vendor string: Tungsten Graphics, Inc Blockquote something wrong here I guess I try to some solutions but didnt work even it cant nvidia-xconfig file after these By the way system get eror sometimes about xorg Sorry for my English thaks for help.

    Read the article

  • Iomega Home Media Network Hard Drive 1TB Cloud Edition failed, data recovery?

    - by lonbon69
    I have a Iomega Home Media Network Drive Cloud Edition 1TB that started clicking and then displayed a failure LED code Power LED and Red LED. I removed the SATA drive and inserted in a 'All in 1 HDD Docking Station' and connected to laptop by USB - Laptop has Win 7 OS. The dock is seen as drive E but cannot access and says 0% data etc. The drive does spin up when I power the dock. Web searches say the drive has EXT3 file system and to use Ubuntu to access drive. I have now setup a dual boot laptop but still do not see the drive using ubuntu. Is there something else I need to do to get it recognised etc. I really would like to recover the data, any suggestions please?

    Read the article

  • 12.4 LTS after update fails to login

    - by user111839
    An update today (30-11-2012) on 12.4 lead to failure to log in. The system gets through its boot process then presents the logins, on choosing any of these immediately returned to log-in screen with no error. Machine is an AMD FX 64 on an Asus MB using the built-in graphics. If no one knows what this might be, what's the alternative distro to Ubuntu? It's the second time something like this has happened after an update in three months, kudos to the Ubuntu team but I need more reliability. Cheers, thanks to all.

    Read the article

  • What's the risk of upgrading over SSH?

    - by C. Ross
    When I run sudo do-release-upgrade over ssh, I get the following message. This session appears to be running under ssh. It is not recommended to perform a upgrade over ssh currently because in case of failure it is harder to recover. If you continue, an additional ssh daemon will be started at port '9004'. Do you want to continue? What is the real risk of upgrading over ssh? How does the additional ssh daemon help mitigate this?

    Read the article

  • Unable to stop TOSHIBA TransMemory

    - by user66498
    I have a USB,when I choose safety remove, occur this error message.How to solve the problem? Unable to stop TOSHIBA TransMemory Error detaching: helper exited with exit code 1: Detaching device /dev/sdb USB device: /sys/devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.2) SYNCHRONIZE CACHE: synchronize cache(10): Fixed format, current; Sense key: Key=9 Additional sense: Logical unit not ready, cause not reportable Info fld=0x0 [0] FAILED: No such file or directory (Continuing despite SYNCHRONIZE CACHE failure.) STOP UNIT: start stop unit: transport: Host_status=0x07 [DID_ERROR] Driver_status=0x00 [DRIVER_OK, SUGGEST_OK] FAILED: No such file or directory

    Read the article

  • Partition table nonresponsive during instal

    - by SunGold
    I started a Ubuntu install, but the impetuous teenager (IT) at the controls "did stuff" that resulted in an install failure. We had arrived at the partition table. Now, there are no clickable actions in the partition part of the installation. "Install Now" returns the message, "No root file defined." How can I use Ubuntu from CD to make a root file or bootable partition? I've been struggling with the previous screwups by IT for 3-4 days, so I am becoming desperate.

    Read the article

  • Importing Data From Excel Using SSIS - Part 1

    Recently while working on a project to import data from an Excel worksheet using SSIS, I realized that sometimes the SSIS Package failed even though when there were no changes in the structure/schema of the Excel worksheet. I investigated it and I noticed that the SSIS Package succeeded for some set of files, but for others it failed. I found that the structure/schema of the worksheet from both these sets of Excel files were the same, the data was the only difference. How come just changing the data can make an SSIS Package fail? What actually causes this failure? What can we do to fix it?

    Read the article

  • Successful business proposal; How to negotiate with employer for bonuses on the project [on hold]

    - by user870018
    I'm the lone programmer at a small business which is falling head-over-heels for a website proposal I wrote on a project they were considering. Next week is the company meeting where it will be formally presented to the owners, and if the project is accepted it could become a (relatively) huge revenue stream when finished. Despite all the buzz I have no financial stake in the success or failure of the project. I know I haven't been profitable and they can't pay me what I should be making. I'm also the only non-management employee with no way to earn a bonus, despite having one of the most demanding jobs in the office. I'd like to know if there's any resources or advice for programmers or employees to negotiate and get invested in a projects success. Just a way to guarantee if I prove my worth I can move up a rung or two.

    Read the article

  • Site Suspended -message at my site and Facebook fan page? [on hold]

    - by Jere_Sumell
    I'm writing blog at Wordpress, and bought Domain park for it for a shorter web address for my readers who I redirect to my blog. Yesterday there was a first time message titled "Account Suspended due to registration information verification failure". I've never changed my contact information at my Web Host, and my contact Information has not been changed. I have Fan page on Facebook too, that my readers' could follow my blog easier, and there was same kind of message on my Facebook site too. Can you tell me, what's going on? I've not been broking any terms of use at my host, and writing good language on my blog. I think it's a some kind of hacker -thing? Is there nothing else to do than contact my web host that they can fix the problem? Can they? I Contacted last night my host, but got no answer yet.

    Read the article

  • Ubuntu will not install on my Dell Inspiron 580

    - by AndrewC
    I'm trying to install ubuntu on my Inspiron 580 (Intel Core i3 4Gb Ram Intel HD Graphics) but am having no success installing from CD or Windows installer all result in a purple rapidly flashing screen with the Ubuntu with 5 dots below it splash which doesn't change. I have tried releases 12.04.1 LTS (CD and windows installer), 11.10 (CD after reading it was certified for the 580) and today 12.10 (CD) all produce the same install failure. My Dell 1704PT monitor is connected to the intel HD board using an HDMI to DVI adaptor though I have tried a VGA cable and still got the same flashing screen. Any help gratefully received as i want to get away from Windows 7 Home Premium.

    Read the article

  • Synchronizing (updating) published files

    - by MucMug
    How can I update a published file and maintain the same URL? After saving an update of a published file on my desktop, it will automatically "synchronise" with the corresponding files at UbuntuOne (and it does). Problem is that the "new file", actually the updated file with the same name, is no longer published. Pressing the publish button results is a new URL. I now have to mail new URL's and change embedded links, as old URL will result in a failure to find the updated file (or indeed any file). I am not sure if it is a bug or a design flaw (maybe intentional?), but it seems strange to me.

    Read the article

  • SQL Server Express 2008 R2 Installation error at Windows 7

    - by Shai Sherman
    Hello, I created install script that will install SQL Server 2008 R2 on windows XP SP3, windows vista and windows 7. One of the command that i used in the installation is for silent installation of SQL Server 2008 R2. When i install it on windows XP everything works just fine but when i try to install it on Windows 7 i get an error. What am I doing wrong? Here is the command line that i use: "Setup.exe /ConfigurationFile=Mysetup.ini" Mysetup.ini file: -------------------------------------Start of ini file --------------------------------- ;SQL SERVER 2008 R2 Configuration File ;Version 1.0, 5 May 2010 ; [SQLSERVER2008] ; Specify the Instance ID for the SQL Server features you have specified. SQL Server directory structure, registry structure, and service names will reflect the instance ID of the SQL Server instance. INSTANCEID="MSSQLSERVER" ; Specifies a Setup work flow, like INSTALL, UNINSTALL, or UPGRADE. This is a required parameter. ACTION="Install" ; Specifies features to install, uninstall, or upgrade. The list of top-level features include SQL, AS, RS, IS, and Tools. The SQL feature will install the database engine, replication, and full-text. The Tools feature will install Management Tools, Books online, Business Intelligence Development Studio, and other shared components. FEATURES=SQLENGINE ; Displays the command line parameters usage HELP="False" ; Specifies that the detailed Setup log should be piped to the console. INDICATEPROGRESS="False" ; Setup will not display any user interface. QUIET="False" ; Setup will display progress only without any user interaction. QUIETSIMPLE="True" ; Specifies that Setup should install into WOW64. This command line argument is not supported on an IA64 or a 32-bit system. ;X86="False" ; Specifies the path to the installation media folder where setup.exe is located. ;MEDIASOURCE="z:\" ; Detailed help for command line argument ENU has not been defined yet. ENU="True" ; Parameter that controls the user interface behavior. Valid values are Normal for the full UI, and AutoAdvance for a simplied UI. ; UIMODE="Normal" ; Specify if errors can be reported to Microsoft to improve future SQL Server releases. Specify 1 or True to enable and 0 or False to disable this feature. ERRORREPORTING="False" ; Specify the root installation directory for native shared components. ;INSTALLSHAREDDIR="D:\Program Files\Microsoft SQL Server" ; Specify the root installation directory for the WOW64 shared components. ;INSTALLSHAREDWOWDIR="D:\Program Files (x86)\Microsoft SQL Server" ; Specify the installation directory. ;INSTANCEDIR="D:\Program Files\Microsoft SQL Server" ; Specify that SQL Server feature usage data can be collected and sent to Microsoft. Specify 1 or True to enable and 0 or False to disable this feature. SQMREPORTING="False" ; Specify a default or named instance. MSSQLSERVER is the default instance for non-Express editions and SQLExpress for Express editions. This parameter is required when installing the SQL Server Database Engine (SQL), Analysis Services (AS), or Reporting Services (RS). INSTANCENAME="SQLEXPRESS" SECURITYMODE=SQL SAPWD=SystemAdmin ; Agent account name AGTSVCACCOUNT="NT AUTHORITY\NETWORK SERVICE" ; Auto-start service after installation. AGTSVCSTARTUPTYPE="Manual" ; Startup type for Integration Services. ;ISSVCSTARTUPTYPE="Automatic" ; Account for Integration Services: Domain\User or system account. ;ISSVCACCOUNT="NT AUTHORITY\NetworkService" ; Controls the service startup type setting after the service has been created. ;ASSVCSTARTUPTYPE="Automatic" ; The collation to be used by Analysis Services. ;ASCOLLATION="Latin1_General_CI_AS" ; The location for the Analysis Services data files. ;ASDATADIR="Data" ; The location for the Analysis Services log files. ;ASLOGDIR="Log" ; The location for the Analysis Services backup files. ;ASBACKUPDIR="Backup" ; The location for the Analysis Services temporary files. ;ASTEMPDIR="Temp" ; The location for the Analysis Services configuration files. ;ASCONFIGDIR="Config" ; Specifies whether or not the MSOLAP provider is allowed to run in process. ;ASPROVIDERMSOLAP="1" ; A port number used to connect to the SharePoint Central Administration web application. ;FARMADMINPORT="0" ; Startup type for the SQL Server service. SQLSVCSTARTUPTYPE="Automatic" ; Level to enable FILESTREAM feature at (0, 1, 2 or 3). FILESTREAMLEVEL="0" ; Set to "1" to enable RANU for SQL Server Express. ENABLERANU="1" ; Specifies a Windows collation or an SQL collation to use for the Database Engine. SQLCOLLATION="SQL_Latin1_General_CP1_CI_AS" ; Account for SQL Server service: Domain\User or system account. SQLSVCACCOUNT="NT Authority\System" ; Default directory for the Database Engine user databases. ;SQLUSERDBDIR="K:\Microsoft SQL Server\MSSQL\Data" ; Default directory for the Database Engine user database logs. ;SQLUSERDBLOGDIR="L:\Microsoft SQL Server\MSSQL\Data\Logs" ; Directory for Database Engine TempDB files. ;SQLTEMPDBDIR="T:\Microsoft SQL Server\MSSQL\Data" ; Directory for the Database Engine TempDB log files. ;SQLTEMPDBLOGDIR="T:\Microsoft SQL Server\MSSQL\Data\Logs" ; Provision current user as a Database Engine system administrator for SQL Server 2008 R2 Express. ADDCURRENTUSERASSQLADMIN="True" ; Specify 0 to disable or 1 to enable the TCP/IP protocol. TCPENABLED="1" ; Specify 0 to disable or 1 to enable the Named Pipes protocol. NPENABLED="0" ; Startup type for Browser Service. BROWSERSVCSTARTUPTYPE="Automatic" ; Specifies how the startup mode of the report server NT service. When ; Manual - Service startup is manual mode (default). ; Automatic - Service startup is automatic mode. ; Disabled - Service is disabled ;RSSVCSTARTUPTYPE="Automatic" ; Specifies which mode report server is installed in. ; Default value: “FilesOnly” ;RSINSTALLMODE="FilesOnlyMode" ; Accept SQL Server 2008 R2 license terms IACCEPTSQLSERVERLICENSETERMS="TRUE" ;setup.exe /CONFIGURATIONFILE=Mysetup.ini /INDICATEPROGRESS --------------------------- End of ini file ------------------------------------- And i get this error: 2010-08-31 18:05:53 Slp: Error result: -2068119551 2010-08-31 18:05:53 Slp: Result facility code: 1211 2010-08-31 18:05:53 Slp: Result error code: 1 2010-08-31 18:05:53 Slp: Sco: Attempting to create base registry key HKEY_LOCAL_MACHINE, machine 2010-08-31 18:05:53 Slp: Sco: Attempting to open registry subkey 2010-08-31 18:05:53 Slp: Sco: Attempting to open registry subkey Software\Microsoft\PCHealth\ErrorReporting\DW\Installed 2010-08-31 18:05:53 Slp: Sco: Attempting to get registry value DW0200 2010-08-31 18:05:53 Slp: Submitted 1 of 1 failures to the Watson data repository What the meaning of this? What do i need to do to fix that problem? Here is the Summary file: Overall summary: Final result: SQL Server installation failed. To continue, investigate the reason for the failure, correct the problem, uninstall SQL Server, and then rerun SQL Server Setup. Exit code (Decimal): -2068119551 Exit facility code: 1211 Exit error code: 1 Exit message: SQL Server installation failed. To continue, investigate the reason for the failure, correct the problem, uninstall SQL Server, and then rerun SQL Server Setup. Start time: 2010-08-31 18:03:44 End time: 2010-08-31 18:05:51 Requested action: Install Log with failure: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\Detail.txt Exception help link: http%3a%2f%2fgo.microsoft.com%2ffwlink%3fLinkId%3d20476%26ProdName%3dMicrosoft%2bSQL%2bServer%26EvtSrc%3dsetup.rll%26EvtID%3d50000%26ProdVer%3d10.50.1600.1%26EvtType%3d0x6121810A%400xC24842DB Machine Properties: Machine name: NVR Machine processor count: 2 OS version: Windows 7 OS service pack: OS region: United States OS language: English (United States) OS architecture: x86 Process architecture: 32 Bit OS clustered: No Product features discovered: Product Instance Instance ID Feature Language Edition Version Clustered Package properties: Description: SQL Server Database Services 2008 R2 ProductName: SQL Server 2008 R2 Type: RTM Version: 10 SPLevel: 0 Installation location: C:\Disk1\setupsql\x86\setup\ Installation edition: EXPRESS User Input Settings: ACTION: Install ADDCURRENTUSERASSQLADMIN: True AGTSVCACCOUNT: NT AUTHORITY\NETWORK SERVICE AGTSVCPASSWORD: * AGTSVCSTARTUPTYPE: Disabled ASBACKUPDIR: Backup ASCOLLATION: Latin1_General_CI_AS ASCONFIGDIR: Config ASDATADIR: Data ASDOMAINGROUP: ASLOGDIR: Log ASPROVIDERMSOLAP: 1 ASSVCACCOUNT: ASSVCPASSWORD: * ASSVCSTARTUPTYPE: Automatic ASSYSADMINACCOUNTS: ASTEMPDIR: Temp BROWSERSVCSTARTUPTYPE: Automatic CONFIGURATIONFILE: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\ConfigurationFile.ini CUSOURCE: ENABLERANU: True ENU: True ERRORREPORTING: False FARMACCOUNT: FARMADMINPORT: 0 FARMPASSWORD: * FEATURES: SQLENGINE FILESTREAMLEVEL: 0 FILESTREAMSHARENAME: FTSVCACCOUNT: FTSVCPASSWORD: * HELP: False IACCEPTSQLSERVERLICENSETERMS: True INDICATEPROGRESS: False INSTALLSHAREDDIR: C:\Program Files\Microsoft SQL Server\ INSTALLSHAREDWOWDIR: C:\Program Files\Microsoft SQL Server\ INSTALLSQLDATADIR: INSTANCEDIR: C:\Program Files\Microsoft SQL Server\ INSTANCEID: MSSQLSERVER INSTANCENAME: SQLEXPRESS ISSVCACCOUNT: NT AUTHORITY\NetworkService ISSVCPASSWORD: * ISSVCSTARTUPTYPE: Automatic NPENABLED: 0 PASSPHRASE: * PCUSOURCE: PID: * QUIET: False QUIETSIMPLE: True ROLE: AllFeatures_WithDefaults RSINSTALLMODE: FilesOnlyMode RSSVCACCOUNT: NT AUTHORITY\NETWORK SERVICE RSSVCPASSWORD: * RSSVCSTARTUPTYPE: Automatic SAPWD: * SECURITYMODE: SQL SQLBACKUPDIR: SQLCOLLATION: SQL_Latin1_General_CP1_CI_AS SQLSVCACCOUNT: NT Authority\System SQLSVCPASSWORD: * SQLSVCSTARTUPTYPE: Automatic SQLSYSADMINACCOUNTS: SQLTEMPDBDIR: SQLTEMPDBLOGDIR: SQLUSERDBDIR: SQLUSERDBLOGDIR: SQMREPORTING: False TCPENABLED: 1 UIMODE: AutoAdvance X86: False Configuration file: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\ConfigurationFile.ini Detailed results: Feature: Database Engine Services Status: Failed: see logs for details MSI status: Passed Configuration status: Failed: see details below Configuration error code: 0x0A2FBD17@1211@1 Configuration error description: The process cannot access the file because it is being used by another process. Configuration log: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\Detail.txt Rules with failures: Global rules: Scenario specific rules: Rules report file: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\SystemConfigurationCheck_Report.htm What should I do and why does this problem occur? Thanks , Shai.

    Read the article

  • Why is Windows Update trying to install an update I don't need?

    - by Oliver Salzburg
    I have a Windows 7 system that currently has a single update pending: Windows Internet Explorer 9 for Windows 7 for x64-based Systems If I try to install the update, Windows Update will: Create a restore point Fail with the error: Code 9C48 Windows Update encountered an error. The event log for the event reads: Installation Failure: Windows failed to install the following update with error 0x80070643: Windows Internet Explorer 9 for Windows 7 for x64-based Systems. If you search the web for that error, there are many other people with the exact same issue. Sadly, I am unable to apply the proposed solutions to my case, because I just installed this system. There is nothing on it, except Windows 7. I installed the system and ran through the updates. I also did the exact same process with this machine several times over the past few days due to a long-term test we just started. I didn't have any problems with any Windows Update on the previous installation runs and I know I didn't do anything different this time because I followed the installation procedures instructions which are to be used during the test. How did this happen and how do I solve it? Further Investigation So, as I always like to do, I ran the update again while running Process Monitor and dug up further details. WindowsUpdate.log First of all, there is a Windows Update log file located at C:\Windows\WindowsUpdate.log which I didn't know about. But I fail to see any significant entry in it, maybe you're more lucky: 2012-04-10 22:46:58:017 956 728 AU AU received approval from Ux for 1 updates 2012-04-10 22:46:58:017 956 728 AU AU setting pending client directive to 'Progress Ux' 2012-04-10 22:46:58:095 956 728 AU BeginInteractiveInstall invoked for Download 2012-04-10 22:46:58:095 956 728 AU Auto-approving update for download, updateId = {B33ACEC1-3265-4D01-9C37-AC0892E95ED9}.100, ForUx=1, IsOwnerUx=1, HasDeadline=0, IsMinor=0 2012-04-10 22:46:58:095 956 728 AU Auto-approved 1 update(s) for download (for Ux) 2012-04-10 22:46:58:110 956 728 AU UpdateDownloadProperties: 0 download(s) are still in progress. 2012-04-10 22:46:58:110 956 728 AU ############# 2012-04-10 22:46:58:110 956 728 AU ## START ## AU: Download updates 2012-04-10 22:46:58:110 956 728 AU ######### 2012-04-10 22:46:58:110 956 728 AU # Approved updates = 1 2012-04-10 22:46:58:110 956 728 AU AU initiated download, updateId = {B33ACEC1-3265-4D01-9C37-AC0892E95ED9}.100, callId = {35DF928B-B428-4BAC-8C63-55295967EFBB} 2012-04-10 22:46:58:110 956 728 AU Setting AU scheduled install time to 2012-04-11 01:00:00 2012-04-10 22:46:58:110 956 728 AU Successfully wrote event for AU health state:0 2012-04-10 22:46:58:110 956 728 AU Currently showing Progress UX client - so not launching any other client 2012-04-10 22:46:58:110 956 bb8 DnldMgr ************* 2012-04-10 22:46:58:110 956 bb8 DnldMgr ** START ** DnldMgr: Downloading updates [CallerId = AutomaticUpdatesWuApp] 2012-04-10 22:46:58:110 956 bb8 DnldMgr ********* 2012-04-10 22:46:58:110 956 bb8 DnldMgr * Call ID = {35DF928B-B428-4BAC-8C63-55295967EFBB} 2012-04-10 22:46:58:110 956 bb8 DnldMgr * Priority = 3, Interactive = 1, Owner is system = 0, Explicit proxy = 0, Proxy session id = 1, ServiceId = {9482F4B4-E343-43B6-B170-9A65BC822C77} 2012-04-10 22:46:58:110 956 bb8 DnldMgr * Updates to download = 1 2012-04-10 22:46:58:110 956 bb8 Agent * Title = Windows Internet Explorer 9 for Windows 7 for x64-based Systems 2012-04-10 22:46:58:110 956 bb8 Agent * UpdateId = {B33ACEC1-3265-4D01-9C37-AC0892E95ED9}.100 2012-04-10 22:46:58:110 956 bb8 Agent * Bundles 1 updates: 2012-04-10 22:46:58:110 956 bb8 Agent * {6D9A90B7-FAF9-4A47-9EFE-A506264873B3}.100 2012-04-10 22:46:58:110 956 bb8 DnldMgr *********** DnldMgr: New download job [UpdateId = {6D9A90B7-FAF9-4A47-9EFE-A506264873B3}.100] *********** 2012-04-10 22:46:58:110 956 728 AU Successfully wrote event for AU health state:0 2012-04-10 22:46:58:110 956 728 AU # Pending download calls = 1 2012-04-10 22:46:58:110 956 728 AU ## RESUMED ## AU: Download update [UpdateId = {B33ACEC1-3265-4D01-9C37-AC0892E95ED9}, succeeded] 2012-04-10 22:46:58:313 956 bb8 Agent ** END ** Agent: Downloading updates [CallerId = AutomaticUpdatesWuApp] 2012-04-10 22:46:58:313 956 bb8 Agent ************* 2012-04-10 22:46:58:313 956 718 AU ######### 2012-04-10 22:46:58:313 956 718 AU ## END ## AU: Download updates 2012-04-10 22:46:58:313 956 718 AU ############# 2012-04-10 22:46:58:313 956 718 AU Setting AU scheduled install time to 2012-04-11 01:00:00 2012-04-10 22:46:58:313 956 718 AU Successfully wrote event for AU health state:0 2012-04-10 22:46:58:313 956 718 AU Currently showing Progress UX client - so not launching any other client 2012-04-10 22:46:58:313 956 718 AU Successfully wrote event for AU health state:0 2012-04-10 22:46:58:313 956 aac AU Getting featured update notifications. fIncludeDismissed = true 2012-04-10 22:46:58:313 956 aac AU No featured updates available. 2012-04-10 22:47:00:107 956 aac AU BeginInteractiveInstall invoked for Install 2012-04-10 22:47:00:107 956 aac AU Auto-approving update for install, updateId = {B33ACEC1-3265-4D01-9C37-AC0892E95ED9}.100, ForUx=1, IsOwnerUx=1, HasDeadline=0, IsMinor=0 2012-04-10 22:47:00:107 956 aac AU Auto-approved 1 update(s) for install (for Ux), installType=1 2012-04-10 22:47:00:107 956 aac AU ############# 2012-04-10 22:47:00:107 956 aac AU ## START ## AU: Install updates 2012-04-10 22:47:00:107 956 aac AU ######### 2012-04-10 22:47:00:107 956 aac AU # Initiating manual install 2012-04-10 22:47:00:107 956 aac AU # Approved updates = 1 2012-04-10 22:47:00:107 956 aac AU ## RESUMED ## AU: Installing update [UpdateId = {B33ACEC1-3265-4D01-9C37-AC0892E95ED9}] 2012-04-10 22:47:13:773 2232 9fc Handler : WARNING: Exit code = 0x8024200B 2012-04-10 22:47:13:773 956 718 AU # WARNING: Install failed, error = 0x80070643 / 0x00009C48 2012-04-10 22:47:13:773 2232 9fc Handler ::::::::: 2012-04-10 22:47:13:773 2232 9fc Handler :: END :: Handler: Command Line Install 2012-04-10 22:47:13:773 2232 9fc Handler ::::::::::::: 2012-04-10 22:47:13:851 956 a7c Agent ********* 2012-04-10 22:47:13:851 956 a7c Agent ** END ** Agent: Installing updates [CallerId = AutomaticUpdates] 2012-04-10 22:47:13:851 956 718 AU Install call completed. 2012-04-10 22:47:13:851 956 a7c Agent ************* 2012-04-10 22:47:13:851 956 718 AU # WARNING: Install call completed, reboot required = No, error = 0x00000000 2012-04-10 22:47:13:851 956 718 AU ######### 2012-04-10 22:47:13:851 956 718 AU ## END ## AU: Installing updates [CallId = {FCFF2A5C-25AB-4FB9-AB2B-35C65CCA6A9F}] 2012-04-10 22:47:13:851 956 718 AU ############# 2012-04-10 22:47:13:851 956 718 AU Install complete for all calls, reboot NOT needed 2012-04-10 22:47:13:851 956 718 AU Setting AU scheduled install time to 2012-04-11 01:00:00 2012-04-10 22:47:13:851 956 718 AU Successfully wrote event for AU health state:0 2012-04-10 22:47:13:851 956 498 AU Getting featured update notifications. fIncludeDismissed = true 2012-04-10 22:47:13:851 956 498 AU No featured updates available. 2012-04-10 22:47:14:366 956 168 AU No featured updates notifications to show 2012-04-10 22:47:14:366 956 168 AU UpdateDownloadProperties: 0 download(s) are still in progress. 2012-04-10 22:47:14:366 956 168 AU Triggering Offline detection (non-interactive) 2012-04-10 22:47:14:366 956 168 AU AU setting pending client directive to 'Install Complete Ux' 2012-04-10 22:47:14:366 956 168 AU Changing existing AU client directive from 'Progress Ux' to 'Install Complete Ux', session id = 0x1 2012-04-10 22:47:14:366 956 168 AU Successfully wrote event for AU health state:0 2012-04-10 22:47:14:366 956 b78 AU ############# 2012-04-10 22:47:14:366 956 b78 AU ## START ## AU: Search for updates 2012-04-10 22:47:14:366 956 b78 AU ######### 2012-04-10 22:47:14:366 956 b78 AU ## RESUMED ## AU: Search for updates [CallId = {0198DD3A-D7B0-48F5-A77D-795F8A1BDCE8}] 2012-04-10 22:47:16:097 956 718 AU # 1 updates detected 2012-04-10 22:47:16:097 956 718 AU ######### 2012-04-10 22:47:16:097 956 718 AU ## END ## AU: Search for updates [CallId = {0198DD3A-D7B0-48F5-A77D-795F8A1BDCE8}] 2012-04-10 22:47:16:097 956 718 AU ############# 2012-04-10 22:47:16:097 956 718 AU No featured updates notifications to show 2012-04-10 22:47:16:097 956 718 AU Setting AU scheduled install time to 2012-04-11 01:00:00 2012-04-10 22:47:16:097 956 718 AU Successfully wrote event for AU health state:0 2012-04-10 22:47:16:097 956 718 AU Successfully wrote event for AU health state:0 2012-04-10 22:47:16:113 956 55c AU Getting featured update notifications. fIncludeDismissed = true 2012-04-10 22:47:16:113 956 55c AU No featured updates available. 2012-04-10 22:47:18:780 956 bb8 Report REPORT EVENT: {27479C66-E930-4F9C-AFF2-27EDD76DED8F} 2012-04-10 22:47:13:773+0200 1 182 101 {B33ACEC1-3265-4D01-9C37-AC0892E95ED9} 100 80070643 AutomaticUpdates Failure Content Install Installation Failure: Windows failed to install the following update with error 0x80070643: Windows Internet Explorer 9 for Windows 7 for x64-based Systems. 2012-04-10 22:47:18:780 956 bb8 Report CWERReporter::HandleEvents - WER report upload completed with status 0x8 2012-04-10 22:47:18:780 956 bb8 Report WER Report sent: 7.5.7601.17514 0x80070643 B33ACEC1-3265-4D01-9C37-AC0892E95ED9 Install 101 Unmanaged 2012-04-10 22:47:18:780 956 bb8 Report CWERReporter finishing event handling. (00000000) WU-IE9-Windows7-x64.exe The actual update that is executed is downloaded and stored at the following location: C:\Windows\SoftwareDistribution\Download\Install\WU-IE9-Windows7-x64.exe Executing that file manually, results in the following error message: IE9_main.log The IE9 installer/updater also creates an own log file located at C:\Windows\IE9_main.log For the update session in question, the installer logged: 00:00.000: ==================================================================== 00:00.016: Started: 2012/04/10 (Y/M/D) 23:10:53.897 (local) 00:00.032: Time Format in this log: MM:ss.mmm (minutes:seconds.milliseconds) 00:00.063: Command line: "C:\Windows\SoftwareDistribution\Download\Install\WU-IE9-Windows7-x64.exe" 00:00.078: INFO: Setup installer for Internet Explorer: 9.0.8112.16421 00:00.094: INFO: Previous version of Internet Explorer: 9.0.8112.16443 00:00.110: INFO: Checking if iexplore.exe's current version is between 9.0.6001.0... 00:00.125: INFO: ...and 9.1.0.0... 00:00.141: INFO: Maximum version on which to run IEAK branding is: 9.1.0.0... 00:00.156: ERROR: A newer version of Internet Explorer is already installed on the system. 00:00.188: ERROR: Internet Explorer version check failed. 01:03.789: INFO: Setup exit code: 0x00009C48 (40008) - A more recent version of Internet Explorer is installed. 01:03.820: INFO: Scheduling upload to IE SQM server: http://sqm.microsoft.com/sqm/ie/sqmserver.dll 01:03.852: INFO: SQM Upload returned 403 01:03.867: INFO: Cleaning up temporary files in: C:\Windows\TEMP\IE978E.tmp 01:03.883: INFO: Unable to remove directory C:\Windows\TEMP\IE978E.tmp, marking for deletion on reboot. 01:03.898: INFO: Released Internet Explorer Installer Mutex Which pretty much confirms what the error message says when executing the update manually; it's simply already installed or even obsolete because a newer version is installed. So, why does it try to keep installing the update? Possible solutions? Uninstalling Windows Internet Explorer 9 and manually installing the cached C:\Windows\SoftwareDistribution\Download\Install\WU-IE9-Windows7-x64.exe will result in the same error after applying all pending updates. Applying the FixIt for the issue You receive “0x80070643” or “0x643” error codes when you try to install .NET Framework updates through Windows Update or Microsoft Updates will not resolve the issue. Applying the suggested solution for the issue Error message when you try to install updates by using the Windows Update or Microsoft Update Web site: "0x80070003" will not resolve the issue. Running the FixIt Automatically diagnose and fix common problems with Windows Update does report having resolved issues with Windows Update, but didn't resolve the issue. Running the FixIt for the issue How to troubleshoot Windows Update or Microsoft Update when you are repeatedly offered an update does not resolve the issue. Neither with normal nor with aggressive settings.

    Read the article

  • Crystal reports - connection to JDBC failed

    - by Gabriela
    Hello, I am trying to make a connection to JDBC(JNDI) in Crystal Reports and I get the following error : Invalid Argument provided. Details: Java Server startup failure. Please verify the PATH (JDK), CLASSPATH and IORFileLocation properties in the CRConfig.xml file. In addition, please verify you are using JDK 1.4. I am using the connector : mysql-connector-java-5.1.6-bin.jar, jDK 1.6. Thank you!

    Read the article

  • Could not load file or assembly 'System.Web.Ajax, Version=3.0.31106.0

    - by Jonesy
    HI folks, I have a .net application (vb.net) and I'm using the ajax control toolkit. It works fine on my production machine but when I upload it to the host (fasthosts) i get this error: Could not load file or assembly 'System.Web.Ajax, Version=3.0.31106.0, Culture=neutral, PublicKeyToken=28f01b0e84b6d53e' or one of its dependencies. The module was expected to contain an assembly manifest. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.BadImageFormatException: Could not load file or assembly 'System.Web.Ajax, Version=3.0.31106.0, Culture=neutral, PublicKeyToken=28f01b0e84b6d53e' or one of its dependencies. The module was expected to contain an assembly manifest. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Assembly Load Trace: The following information can be helpful to determine why the assembly 'System.Web.Ajax, Version=3.0.31106.0, Culture=neutral, PublicKeyToken=28f01b0e84b6d53e' could not be loaded. WRN: Assembly binding logging is turned OFF. To enable assembly bind failure logging, set the registry value [HKLM\Software\Microsoft\Fusion!EnableLog] (DWORD) to 1. Note: There is some performance penalty associated with assembly bind failure logging. To turn this feature off, remove the registry value [HKLM\Software\Microsoft\Fusion!EnableLog]. Stack Trace: [BadImageFormatException: Could not load file or assembly 'System.Web.Ajax, Version=3.0.31106.0, Culture=neutral, PublicKeyToken=28f01b0e84b6d53e' or one of its dependencies. The module was expected to contain an assembly manifest.] AjaxControlToolkit.ToolkitScriptManager.ApplyAssembly(ScriptReference script, Boolean isComposite) +0 AjaxControlToolkit.ToolkitScriptManager.OnResolveScriptReference(ScriptReferenceEventArgs e) +167 System.Web.UI.ScriptManager.RegisterScripts() +191 System.Web.UI.ScriptManager.OnPagePreRenderComplete(Object sender, EventArgs e) +113 System.Web.UI.Page.OnPreRenderComplete(EventArgs e) +8698462 System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +1029 Here is my web.conf file. Its very simple: <system.web> <customErrors mode="Off"/> <compilation debug="true"> <assemblies> <add assembly="System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35"/> <add assembly="System.Web.Extensions.Design, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35"/> <add assembly="System.Design, Version=2.0.0.0, Culture=neutral, PublicKeyToken=B03F5F7F11D50A3A"/> <add assembly="System.Windows.Forms, Version=2.0.0.0, Culture=neutral, PublicKeyToken=B77A5C561934E089"/></assemblies></compilation></system.web> Does anyone know whats up? -- Billy

    Read the article

  • Paypal Sandbox Do Direct Payment Internal Error 10001 Timeout Processing Request

    - by user552968
    This is what I'm sending to https://api-3t.sandbox.paypal.com/nvp: VERSION = 65.0 SIGNATURE = AFcWxV21C7fd0v3bYYYRCpSSRl31AxdW2pQp.tWHTjGNcHflR-LJhJ0t USER = seller_1283487740_biz_api1.gmail.com PWD = 1283487748 AMOUNT = 50.00 CREDITCARDTYPE = Visa ACCT = 4031477440127509 EXPDATE = 12/2015 CVV2 =123 IPADDRESS = 127.0.0.1 METHOD = DoDirectPayment I can GetBalance, I can produce other errors when I intentionally send something wrong, but DoDirectPayment or DoAuthorization returns this: TIMESTAMP = 2010-12-24T03:35:10Z CORRELATIONID = 2ca329fdbe3c0 ACK = Failure L_ERRORCODE0 = 10001 L_SHORTMESSAGE0 = Internal Error L_LONGMESSAGE0 = Timeout processing request

    Read the article

  • SQL 2008 R2 login/network issue

    - by martinjd
    I have a Windows Server 2008 R2 new clean install , not a VM, that I have added to a Windows Server 2003 based domain using my account which has domain admin rights. The domain functional level is 2003. I performed a clean install of SQL Server 2008 R2 using my account which has domain admin rights. The installation completed without any errors. I logged into SSMS locally and attempted to add another domain account by clicking Search, Advanced and finding the user in the domain. When I return to the "Dialog - New" window and click OK I receive the following error: Create failed for Login 'Domain\User'. (Microsoft.SqlServer.Smo) An exception occurred while executing a Transact-SQL statement or batch. (Microsoft.SqlServer.ConnectionInfo) Windows NT user or group 'Domain\User' not found. Check the name again. (Microsoft SQL Server, Error: 15401) I have verified that the firewall is off, tried adding a different domain user, tried using SA to add a user, installed the hotfix for KB 976494 and verified that the Local Security Policy for Domain Member: Digitally encrypt or sign secure channel Domain Member: Digitally encrypt secure channel Domain Member: Digitally sign secure channel are disabled none of which have made a difference. I can RDP to a Server 2003 server running SQL 2008 and add the same domain user without issue. Also if I try to connect with SSMS to the sql server from another system on the domain using my account I get the following error: Login failed. The login is from an untrusted domain and cannot be used with Windows authentication. (Microsoft SQL Server, Error: 18452) and on the database server I see the following in the security event log: An account failed to log on. Subject: Security ID: NULL SID Account Name: - Account Domain: - Logon ID: 0x0 Logon Type: 3 Account For Which Logon Failed: Security ID: NULL SID Account Name: myUserName Account Domain: MYDOMAIN Failure Information: Failure Reason: An Error occured during Logon. Status: 0xc000018d Sub Status: 0x0 Process Information: Caller Process ID: 0x0 Caller Process Name: - Network Information: Workstation Name: MYWKS Source Network Address: - Source Port: - Detailed Authentication Information: Logon Process: NtLmSsp Authentication Package: NTLM Transited Services: - Package Name (NTLM only): - Key Length: 0 I am sure that the "NULL SID" has some significant meaning but have no idea at this point what the issue could be.

    Read the article

< Previous Page | 89 90 91 92 93 94 95 96 97 98 99 100  | Next Page >