Search Results

Search found 4426 results on 178 pages for 'cs student'.

Page 94/178 | < Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >

  • IP KVM switch, or serial console box for remote admin?

    - by grahzny
    We have a small server farm (11 now, may add more in the future) of HP Proliant DL160 G6s. They all run either Linux (server only, no X11) or VMware ESX. We had intended to get models with iLO, in case BIOS-level remote admin became an issue, but that didn't happen. I had an IP KVM switch recommended to me (along with some sort of Remote Reboot hardware.) I've since realized that none of our machines need GUI administration, so perhaps a serial console switch would be a cheaper and more appropriate option. Something like this: http://www.kvm-switches-online.com/serimux-cs-32.html Do you folks have an opinions on which way is a better choice? Should we go for the ease of setup (plug and go, instead of turning on the feature in the BIOS and making sure the serial settings are correct) and the flexibility of an IP KVM switch even with the extra cost? Or is a serial console switch just fine?

    Read the article

  • Memcached failover

    - by user25164
    We have 2 memcached servers configured and use the Eniym client. When one of the server is down, it appears this server is added to the deadServers list (ServerPool.cs) and tries to resurrect the server every 10seconds (we have configured deadTimeOut to be 10seconds). Attempting to connect to the failed server causes a TCP timeout, the pages take a long time to load which results in bad user experience. 1) What is the standard way of resolving this issue? There are some posts about removing the server from the deadServers list. Is it okay to do this? 2) What is the recommended deadTimeOut setting (I understand by default it's 2 mins and we've changed it to 10seconds in our implementation) 3) Am I correct in my understanding that the cached data is not replicated across Server 1 and Server 2? If Server 1 is down, then it goes to the database to fetch these values (and it doesn't really check Server2)? Any help is really appreciated.

    Read the article

  • Are these components compatible and are there any significant bottlenecks?

    - by Tom Gullen
    I'm trying to buy a new pc, for software dev and a bit of gaming. I already have a 500gb HDD , and a PCI sound card I want to use as well. Is all this stuff compatible, and will it all work together and are there any significant bottlenecks? Case, Mobo and PSU "Primo Motion" AMD 880G DDR3 Ready Barebones (Socket AM3) http://www.overclockers.co.uk/showproduct.php?prodid=FS-268-OK&groupid=43&catid=1817&subcat= SSD 64GB Crucial RealSSD C300 64GB 2.5" SATA 6Gb/s Solid State Hard Drive http://www.overclockers.co.uk/showproduct.php?prodid=HD-007-CR&groupid=1657&catid=1660&subcat=1668 CPU AMD Phenom II X6 Six Core 1090T Black Edition 3.20GHz (Socket AM3) http://www.overclockers.co.uk/showproduct.php?prodid=CP-266-AM&groupid=701&catid=6&subcat=1944 RAM 8GB Corsair Vengeance 8GB (2x4GB) DDR3 PC3-15000C9 1866MHz Dual Channel Kit http://www.overclockers.co.uk/showproduct.php?prodid=MY-292-CS&groupid=701&catid=8&subcat=1387 Graphics XFX ATI Radeon HD 5770 1024MB GDDR5 PCI-Express Graphics Card http://www.overclockers.co.uk/showproduct.php?prodid=GX-149-XF

    Read the article

  • Windows Server 2008R2 IIS7.5, Requests getting 401 status

    - by TLBH
    We have a web site running in windows server 2008r2 iis7.5 and we are seeing several errors reported from our global error handler saying that "Request Timed Out". I matched up one to the IIS log file and see the request took 135116 (presumably milliseconds) had an sc-status of 401 an sc-sub0status of 0 and an sc-win32-status of 64. 2 requests failed in these way but lots of surrounding requests (1979 successful requests vs 2 fails) for the same user went through perfectly fine- with the same cs-username which makes a 401 seem a little odd. The target of the requests is an ASP.Net web service's web method called by the .net client library- it's called a lot of times per user (3 times per second) to keep a page updated. We're getting some users reportng seeing a freezing effect and I think this may be the cause, any ideas? Peter

    Read the article

  • Bad Resolution. Running Three screens at the same time

    - by Carl
    Hi I am currently using three screens at the same time with my ATI 5770 & an active displayport converter. The thing is that the third screen ( the one that is using the active displayport converter ) is showing terrible resolution compared to my other two screens. ( Samsung syncmaster p23 ) two of my screens got a max resolution of 1920* 1090, meanwhile the third on is only capable of 1600 * 1200. Do any of u guys got any solution to this problem? Btw, This is how the Active Displayport converter looks like http://accessories.us.dell.com/sna/products/Cables/productdetail.aspx?c=us&l=en&s=dhs&cs=19&sku=330-5521#Overview

    Read the article

  • Tomato vs X-Wrt Wireless Router Firmware - which is better?

    - by wag2639
    A few years ago, I've switched over from DD-WRT to Tomato and I haven't looked back since. Before I did, I poked around with OpenWRT but found it too confusing or annoying to use (and I'm a CS major and setup and configured Linux servers using SSH). I'm probably not going back to DD-WRT because of all the controversy but I was wondering how X-Wrt is nowadays? From the screenshots, it looks a lot more featured packed than Tomato and that definitely has its appeal. Then again, simplicity has its advantages to. Any thoughts?

    Read the article

  • One-Way Backup Service? [closed]

    - by Jon Rodriguez
    Up until a month ago, my girlfriend has used MobileMe to backup all the files on her MacBook. This turned out terribly when a quirk of MobileMe caused it to erase all of her files on MobileMe, and then sync the newly-erased MobileMe down to her computer, erasing everything. A week's worth of college essays and CS homework were gone. Now, I am terrified of any commercial cloud-backup solutions because of the possibility of this happening. Going off the list provided in these answers, could you please help me find a good backup service that is completely one-way? I want a service where there is literally not a single line of code that has the possibility of writing to my computer's drive. I want a pure one-way backup service.

    Read the article

  • Installing Trial version

    - by Veejay
    I need the Abode CS 4 software for only 50 days. Unfortunately it allows me a trial of only 30 days. Here's what I plan to do. I have two partitions on my computer - one with vista and one with win 7. Can I first install Adobe s/w trial on Vista and after 30 days install it on Win 7. Will it work and is it legal to do so? Thanks. Any other alternatives are welcome

    Read the article

  • Cheap machine with Xen to have more than one personal dev servers with RAID option?

    - by AJ
    I do not have a lot of money so when I need a personal dev servers I decided I will use Xen on one machine to run various OS's. Although, I really like Dell Zino (http://www.dell.com/us/en/home/desktops/inspiron-zino-hd/pd.aspx?refid=inspiron-zino-hd&cs=19&s=dhs) as a very economical and compact PC which can be scaled to 8GB of RAM, I do not know how to have a RAID setup, for the backup. Is there an economical way to add a RAID setup to Dell Zino or I would have to invest in a proper box for that? Thanks for your help in advance. **Also, please let me know if this question is not meant for this forum.

    Read the article

  • Intel site says VT-x is supported on my CPU, but tests say otherwise

    - by Anshul
    I have a laptop with an Intel 2nd Gen. i7-2729QM (http://ark.intel.com/products/50067/) and the Intel site says that it supports VT-x, but I've downloaded the Intel Processor Identification Utility (http://www.intel.com/support/processors/tools/piu/sb/CS-014921.htm) and the test says that my CPU does not have VT-x. There is no option in my BIOS that allows me to enable/disable VT-x. I researched my laptop model (SAGER NP8170) and most forums say that it's enabled by default and there's no option in the BIOS. So assuming that's true, what gives? I also downloaded another tool called SecurAble from GRC and it also says that my CPU doesn't support VT-x. VirtualBox also says that my CPU does not support virtualization. My mind is boggled by why it says on the Intel site that my CPU supports VT-x but all other tests show otherwise. Anyone know what's going on? Thanks in advance.

    Read the article

  • Getting some garbage text when tar-ing a file

    - by Ramy
    when I run the following command: tar -c music.tar iTunes\ Music/ But I get the following garbage output. b????n5???z???V_o?P?O3|?b???i?Pl?jH??8??z5??????~D|_($?|b??:???š`?s7 ?%z\??Jj????K????Z??V?)?A4 2??}?4?(??#?P??ykX ?Q?e<?w?U????Y?8n??s? 1B??F.f? ?X9Lb=8??@????|?h?d???I??L?]??????-????gx??l????n?cs{f???f???6?M(?u??6??|pX?nH?V???$???????7??n?H???Yua??Xn?;{?JP?????7?@R?f_?j?*????3M?z?s9???"??0?$1??7:w???????|D_?????EjtO????????P?Y?-? xVF???Uwky?u?Yt?h ???K ?nJh?]K?J-?2??#Q????~?~B)O?MH?? "??6#?Q,uNG?~??4t?=^C I don't really care if I'm just missing some font library. But I haven't run this to completion because...well i'm not really sure what it's doing. any help appreciated.

    Read the article

  • Is there an easily configurable way to inject data into IIS 6 SMTP logs?

    - by Lorcan O'Neill
    I am using IIS 6 SMTP server to send out some mail on our behalf. I am also storing each message we send in a SQL table - with a UUID representing each message. I would like to be able to inject additional data into the SMTP logs located in SMTPSVC1 - an additional field which would contain this UUID in the event of a RCPT cs-method call. This is so that I can check a one-to-one relationship between messages sent in SQL and messages actually sent through SMTP. If possible, I would like to avoid writing a C++ custom logger as some sites I've viewed have suggested. Is there an easily configurable way to inject this data into IIS 6 logs? Even if it was only the ability to perform a regex on the data/headers of the outgoing email, that would be enough. Thanks!

    Read the article

  • Changing size of window when testing Adobe AIR mobile applications

    - by Peter
    Im making a mobile phone Android application in Flash CS 5.5. I set the width/height of the stage to 480/800 px. When I hit CTRL+ENTER to test run the application I get a window that is 480/800 px. It cannot be resized. I want to change the size of that window WITHOUT changing the stage width/height. For example if I run the APK on a mobile phone with a 1000x1000 display the flash will scale automatically to fit the 480/800 stage to the 1000x1000 screen. So it should be possible to change the window size to 1000x1000 without having to change the stage width/height. But how?

    Read the article

  • Am I using too much memory? (Rails on EC2 with Resque)

    - by Stpn
    I am looking at the memory usage of the Rails application (it uses background processes via Resque) and since the common answer to the question, "how many workers is too many" was "test and see", I ran some memory commands and wonder if someone can help figuring if the memory usage is high enough already, or I can still add some extra workers.. so (this is all under the maximum load): $ free -t -m total used free shared buffers cached Mem: 1756 1532 223 0 12 229 -/+ buffers/cache: 1291 464 Swap: 895 10 885 Total: 2652 1543 1108 $ vmstat procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 10588 156172 13400 326476 1 6 4 0 5 4 1 0 99 0 If there is any extra info I can provide to help answer this, I would be happy to do so. If the question is strange in some way, please let me know I'd be glad to fix etc..

    Read the article

  • IIS returning plain Forbidden response. No HTTP code

    - by Alex Pineda
    I'm running a ServiceStack application on IIS. My regular services work fine and have not had any problems with permissions. My new project involves providing generated pdfs. I gave IIS_IUSRS read/write permissions to the Temp directory under my app directory. I also allow non SSL connections to this directory. When I browse to the file which ServiceStack is supposed to automatically serve up (eg. http://ryu.com/Temp/201310171723337631.pdf ) I get this: Forbidden Request.HttpMethod: GET Request.PathInfo: Request.QueryString: Request.RawUrl: /ryu/Temp/201310171723337631.pdf App.IsIntegratedPipeline: True App.WebHostPhysicalPath: C:\inetpub\ryu App.WebHostRootFileNames: [global.asax,global.asax.cs,web.config,bin,temp] Now this doesn't look like a ServiceStack error message, more like IIS, but I'm not certain as to how to get to the bottom of this. Authorization settings are Allow All.

    Read the article

  • Search desktop files using a list of keywords stored in a text file

    - by Tod1d
    I have a list of 1285 keywords (database object names) that I have compiled into a TXT file; one keyword per line. I would like to search a directory of files (most have a .aspx or .cs extension) using this list of keywords. My main goal is find out which of the 1285 database objects are being referenced in these files. Can anyone recommend a tool that could accomplish this? Otherwise, I will just create my own. Thanks.

    Read the article

  • FFMPEG settings for Youtube and facebook video uploads

    - by eco_bach
    Can any FFMPEG experts share their preferred settings for video conversion to both Youtube and Facebook? For youtube I am following these guidelines and my video size is 480P @ 24 fps Audio Codec: AAC-LC Channels: Stereo or Stereo + 5.1<br> Sample rate 96khz or 48 khz<br> Video Codec: H.264 Progressive scan (no interlacing)<br> High Profile<br> 2 consecutive B frames<br> Closed GOP. GOP of half the frame rate.<br> CABAC<br> Variable bitrate. No bitrate limit required Color Space: 4.2.0 http://support.google.com/youtube/bin/static.py?hl=en&topic=1728573&guide=1728585&page=guide.cs

    Read the article

  • Uncompiled WCF on IIS7: The type could not be found

    - by Jimmy
    Hello, I've been trying to follow this tutorial for deploying a WCF sample to IIS . I can't get it to work. This is a hosted site, but I do have IIS Manager access to the server. However, in step 2 of the tutorial, I can't "create a new IIS application that is physically located in this application directory". I can't seem to find a menu item, context menu item, or what not to create a new application. I've been right-clicking everywhere like crazy and still can't figure out how to create a new app. I suppose that's probably the root issue, but I tried a few other things (described below) just in case that actually is not the issue. This is "deployed" at http://test.com.cws1.my-hosting-panel.com/IISHostedCalcService/Service.svc . The error says: The type 'Microsoft.ServiceModel.Samples.CalculatorService', provided as the Service attribute value in the ServiceHost directive, or provided in the configuration element system.serviceModel/serviceHostingEnvironment/serviceActivations could not be found. I also tried to create a virtual dir (IISHostedCalc) in dotnetpanel that points to IISHostedCalcService . When I navigate to http://test.com.cws1.my-hosting-panel.com/IISHostedCalc/Service.svc , then there is a different error: This collection already contains an address with scheme http. There can be at most one address per scheme in this collection. As per the tutorial, there was no compiling involved; I just dropped the files on the server as follow inside the folder IISHostedCalcService: service.svc Web.config Service.cs service.svc contains: <%@ServiceHost language=c# Debug="true" Service="Microsoft.ServiceModel.Samples.CalculatorService"%> (I tried with quotes around the c# attribute, as this looks a little strange without quotes, but it made no difference) Web.config contains: <?xml version="1.0" encoding="utf-8" ?> <configuration> <system.serviceModel> <services> <service name="Microsoft.ServiceModel.Samples.CalculatorService"> <!-- This endpoint is exposed at the base address provided by host: http://localhost/servicemodelsamples/service.svc --> <endpoint address="" binding="wsHttpBinding" contract="Microsoft.ServiceModel.Samples.ICalculator" /> <!-- The mex endpoint is explosed at http://localhost/servicemodelsamples/service.svc/mex --> <endpoint address="mex" binding="mexHttpBinding" contract="IMetadataExchange" /> </service> </services> </system.serviceModel> <system.web> <customErrors mode="Off"/> </system.web> </configuration> Service.cs contains: using System; using System.ServiceModel; namespace Microsoft.ServiceModel.Samples { [ServiceContract] public interface ICalculator { [OperationContract] double Add(double n1, double n2); [OperationContract] double Subtract(double n1, double n2); [OperationContract] double Multiply(double n1, double n2); [OperationContract] double Divide(double n1, double n2); } public class CalculatorService : ICalculator { public double Add(double n1, double n2) { return n1 + n2; } public double Subtract(double n1, double n2) { return n1 - n2; } public double Multiply(double n1, double n2) { return n1 * n2; } public double Divide(double n1, double n2) { return n1 / n2; } } }

    Read the article

  • SignalR cannot read property client of undefined

    - by polonskyg
    I'm trying to add SignalR to my project (ASPNET MVC 4). But I can't make it work. In the below image you can see the error I'm receiving. I've read a lot of stackoverflow posts but none of them is resolving my issue. This is what I did so far: 1) Ran Install-Package Microsoft.AspNet.SignalR -Pre 2) Added RouteTable.Routes.MapHubs(); in Global.asax.cs Application_Start() 3) If I go to http://localhost:9096/Gdp.IServer.Web/signalr/hubs I can see the file content 4) Added <modules runAllManagedModulesForAllRequests="true"/> to Web.Config 5) Created folder Hubs in the root of the MVC application 6) Moved jquery and signalR scripts to /Scripts/lib folder (I'm not using jquery 1.6.4, I'm using the latest) This is my Index.cshtml <h2>List of Messages</h2> <div class="container"> <input type="text" id="message" /> <input type="button" id="sendmessage" value="Send" /> <input type="hidden" id="displayname" /> <ul id="discussion"> </ul> </div> @section pageScripts { <!--Reference the SignalR library. --> <script src="@Url.Content("~/Scripts/jquery.signalR-1.0.0-rc1.min.js")" type="text/javascript"></script> <!--Reference the autogenerated SignalR hub script. --> <script type="text/javascript" src="~/signalr/hubs"></script> <script src="@Url.Content("~/Scripts/map.js")" type="text/javascript"></script> } This is my IServerHub.cs file (located inside Hubs folder) namespace Gdp.IServer.Ui.Web.Hubs { using Microsoft.AspNet.SignalR.Hubs; [HubName("iServerHub")] public class IServerHub : Hub { public void Send(string name, string message) { Clients.All.broadcastMessage(name, message); } } } And this is map.js $(function () { // Declare a proxy to reference the hub. var clientServerHub = $.connection.iServerHub; // Create a function that the hub can call to broadcast messages. clientServerHub.client.broadcastMessage = function (name, message) { $('#discussion').append('<li><strong>' + name + '</strong>:&nbsp;&nbsp;' + message + '</li>'); }; // Get the user name and store it to prepend to messages. $('#displayname').val(prompt('Enter your name:', '')); // Set initial focus to message input box. $('#message').focus(); // Start the connection. $.connection.hub.start().done(function () { $('#sendmessage').click(function () { // Html encode display name and message. var encodedName = $('<div />').text($('#displayname').val()).html(); var encodedMsg = $('<div />').text($('#message').val()).html(); // Call the Send method on the hub. clientServerHub.server.send(encodedName, encodedMsg); // Clear text box and reset focus for next comment. $('#message').val('').focus(); }); }); }); The DLL's I see references for SignalR are: Microsoft.AspNet.SignalR.Core Microsoft.AspNet.SignalR.Owin Microsoft.AspNet.SignalR.SystemWeb Any ideas how to get it work? Should I make any change because the scripts are in /Script/lib folder? NOTE I'm following the instruction found here on how to set up Windsor Castle to make it work with SignalR, and again, seems that the proxy cannot be created and I'm getting the same error: Cannot read property client of undefined meaning that the proxy to the hub was not created This is how I have it in the server public class IncidentServerHub : Hub and like this in the client var clientServerHub = $.connection.incidentServerHub; Again, I can see the dynamically created file here: /GdpSoftware.Server.Web/signalr/hubs So, Why the proxy is not created? Thanks in advance!!! Guillermo.

    Read the article

  • MVVM: Binding radio buttons to a view model?

    - by David Veeneman
    I have been trying to bind a group of radio buttons to a view model using the IsChecked button. After reviewing other posts, it appears that the IsChecked property simply doesn't work. I have put together a short demo that reproduces the problem, which I have included below. Here is my question: Is there a straightforward and reliable way to bind radio buttons using MVVM? Thanks. Additional information: The IsChecked property doesn't work for two reasons: When a button is selected, the IsChecked properties of other buttons in the group don't get set to false. When a button is selected, its own IsChecked property does not get set after the first time the button is selected. I am guessing that the binding is getting trashed by WPF on the first click. Demo project: Here is the code and markup for a simple demo that reproduces the problem. Create a WPF project and replace the markup in Window1.xaml with the following: <Window x:Class="WpfApplication1.Window1" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" Title="Window1" Height="300" Width="300" Loaded="Window_Loaded"> <StackPanel> <RadioButton Content="Button A" IsChecked="{Binding Path=ButtonAIsChecked, Mode=TwoWay}" /> <RadioButton Content="Button B" IsChecked="{Binding Path=ButtonBIsChecked, Mode=TwoWay}" /> </StackPanel> </Window> Replace the code in Window1.xaml.cs with the following code (a hack), which sets the view model: using System.Windows; namespace WpfApplication1 { /// <summary> /// Interaction logic for Window1.xaml /// </summary> public partial class Window1 : Window { public Window1() { InitializeComponent(); } private void Window_Loaded(object sender, RoutedEventArgs e) { this.DataContext = new Window1ViewModel(); } } } Now add the following code to the project as Window1ViewModel.cs: using System.Windows; namespace WpfApplication1 { public class Window1ViewModel { private bool p_ButtonAIsChecked; /// <summary> /// Summary /// </summary> public bool ButtonAIsChecked { get { return p_ButtonAIsChecked; } set { p_ButtonAIsChecked = value; MessageBox.Show(string.Format("Button A is checked: {0}", value)); } } private bool p_ButtonBIsChecked; /// <summary> /// Summary /// </summary> public bool ButtonBIsChecked { get { return p_ButtonBIsChecked; } set { p_ButtonBIsChecked = value; MessageBox.Show(string.Format("Button B is checked: {0}", value)); } } } } To reproduce the problem, run the app and click Button A. A message box will appear, saying that Button A's IsChecked property has been set to true. Now select Button B. Another message box will appear, saying that Button B's IsChecked property has been set to true, but there is no message box indicating that Button A's IsChecked property has been set to false--the property hasn't been changed. Now click Button A again. The button will be selected in the window, but no message box will appear--the IsChecked property has not been changed. Finally, click on Button B again--same result. The IsChecked property is not updated at all for either button after the button is first clicked.

    Read the article

  • "Unable to read data from the transport connection: net_io_connectionclosed." - Windows Vista Busine

    - by John DaCosta
    Unable to test sending email from .NET code in Windows Vista Business. I am writing code which I will migrate to an SSIS Package once it its proven. The code is to send an error message via email to a list of recipients. The code is below, however I am getting an exception when I execute the code. I created a simple class to do the mailing... the design could be better, I am testing functionality before implementing more robust functionality, methods, etc. namespace LabDemos { class Program { static void Main(string[] args) { Mailer m = new Mailer(); m.test(); } } } namespace LabDemos { class MyMailer { List<string> _to = new List<string>(); List<string> _cc = new List<string>(); List<string> _bcc = new List<string>(); String _msgFrom = ""; String _msgSubject = ""; String _msgBody = ""; public void test(){ //create the mail message MailMessage mail = new MailMessage(); //set the addresses mail.From = new MailAddress("[email protected]"); //set the content mail.Subject = "This is an email"; mail.Body = "this is a sample body"; mail.IsBodyHtml = false; //send the message SmtpClient smtp = new SmtpClient(); smtp.Host = "emailservername"; smtp.Port = 25; smtp.UseDefaultCredentials = true; smtp.Send(mail); } } Exception Message Inner Exception {"Unable to read data from the transport connection: net_io_connectionclosed."} Stack Trace " at System.Net.Mail.SmtpReplyReaderFactory.ProcessRead(Byte[] buffer, Int32 offset, Int32 read, Boolean readLine)\r\n at System.Net.Mail.SmtpReplyReaderFactory.ReadLines(SmtpReplyReader caller, Boolean oneLine)\r\n at System.Net.Mail.SmtpReplyReaderFactory.ReadLine(SmtpReplyReader caller)\r\n at System.Net.Mail.SmtpConnection.GetConnection(String host, Int32 port)\r\n at System.Net.Mail.SmtpTransport.GetConnection(String host, Int32 port)\r\n at System.Net.Mail.SmtpClient.GetConnection()\r\n at System.Net.Mail.SmtpClient.Send(MailMessage message)" Outer Exception System.Net.Mail.SmtpException was unhandled Message="Failure sending mail." Source="System" StackTrace: at System.Net.Mail.SmtpClient.Send(MailMessage message) at LabDemos.Mailer.test() in C:\Users\username\Documents\Visual Studio 2008\Projects\LabDemos\LabDemos\Mailer.cs:line 40 at LabDemos.Program.Main(String[] args) in C:\Users\username\Documents\Visual Studio 2008\Projects\LabDemos\LabDemos\Program.cs:line 48 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.nExecuteAssembly(Assembly assembly, String[] args) at System.Runtime.Hosting.ManifestRunner.Run(Boolean checkAptModel) at System.Runtime.Hosting.ManifestRunner.ExecuteAsAssembly() at System.Runtime.Hosting.ApplicationActivator.CreateInstance(ActivationContext activationContext, String[] activationCustomData) at System.Runtime.Hosting.ApplicationActivator.CreateInstance(ActivationContext activationContext) at System.Activator.CreateInstance(ActivationContext activationContext) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssemblyDebugInZone() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException: System.IO.IOException Message="Unable to read data from the transport connection: net_io_connectionclosed." Source="System" StackTrace: at System.Net.Mail.SmtpReplyReaderFactory.ProcessRead(Byte[] buffer, Int32 offset, Int32 read, Boolean readLine) at System.Net.Mail.SmtpReplyReaderFactory.ReadLines(SmtpReplyReader caller, Boolean oneLine) at System.Net.Mail.SmtpReplyReaderFactory.ReadLine(SmtpReplyReader caller) at System.Net.Mail.SmtpConnection.GetConnection(String host, Int32 port) at System.Net.Mail.SmtpTransport.GetConnection(String host, Int32 port) at System.Net.Mail.SmtpClient.GetConnection() at System.Net.Mail.SmtpClient.Send(MailMessage message) InnerException:

    Read the article

  • java: Read text file and store the info in an array using scanner class

    - by Amateur
    Hi, I have a text file include Student Grades like Kim $ 40 $ 45 Jack $ 35 $ 40 I'm trying to read this data from the text file and store the information into an array list using Scanner Class could any one guied me to write the code correctly ? Here is what I have so far public class ReadStudentsGrade { public static void main(String[] args) throws IOException { ArrayList stuRec = new ArrayList(); File file = new File("c:\\StudentGrade.txt"); try { Scanner scanner = new Scanner(file).useDelimiter("$"); while (scanner.hasNextLine()) { String stuName = scanner.nextLine(); int midTirmGrade = scanner.nextInt(); int finalGrade = scanner.nextInt(); System.out.println(stuName + " " + midTirmGrade + " " + finalGrade); } } catch (FileNotFoundException e) { e.printStackTrace(); } }

    Read the article

  • Using C# FindControl to find a user-control in the master page

    - by Jisaak
    So all I want to do is simply find a user control I load based on a drop down selection. I have the user control added but now I'm trying to find the control so I can access a couple properties off of it and I can't find the control for the life of me. I'm actually doing all of this in the master page and there is no code in the default.aspx page itself. Any help would be appreciated. MasterPage.aspx <body> <form id="form1" runat="server"> <div> <asp:ScriptManager runat="server"> </asp:ScriptManager> </div> <asp:UpdatePanel ID="UpdatePanel2" runat="server" UpdateMode="Conditional" ChildrenAsTriggers="false" OnLoad="UpdatePanel2_Load"> <ContentTemplate> <div class="toolbar"> <div class="section"> <asp:DropDownList ID="ddlDesiredPage" runat="server" AutoPostBack="True" EnableViewState="True" OnSelectedIndexChanged="goToSelectedPage"> </asp:DropDownList> &nbsp; <asp:DropDownList ID="ddlDesiredPageSP" runat="server" AutoPostBack="True" EnableViewState="True" OnSelectedIndexChanged="goToSelectedPage"> </asp:DropDownList> <br /> <span class="toolbarText">Select a Page to Edit</span> </div> <div class="options"> <div class="toolbarButton"> <asp:LinkButton ID="lnkSave" CssClass="modal" runat="server" OnClick="lnkSave_Click"><span class="icon" id="saveIcon" title="Save"></span>Save</asp:LinkButton> </div> </div> </div> </ContentTemplate> <Triggers> </Triggers> </asp:UpdatePanel> <div id="contentContainer"> <asp:UpdatePanel ID="UpdatePanel1" runat="server" OnLoad="UpdatePanel1_Load" UpdateMode="Conditional" ChildrenAsTriggers="False"> <ContentTemplate> <asp:ContentPlaceHolder ID="ContentPlaceHolder1" runat="server"> </asp:ContentPlaceHolder> </ContentTemplate> <Triggers> <asp:AsyncPostBackTrigger ControlID="lnkHome" EventName="Click" /> <asp:AsyncPostBackTrigger ControlID="rdoTemplate" EventName="SelectedIndexChanged" /> </Triggers> </asp:UpdatePanel> </div> MasterPage.cs protected void goToSelectedPage(object sender, System.EventArgs e) { temp1 ct = this.Page.Master.LoadControl("temp1.ascx") as temp1; ct.ID = "TestMe"; this.UpdatePanel1.ContentTemplateContainer.Controls.Add(ct); } //This is where I CANNOT SEEM TO FIND THE CONTROL //////////////////////////////////////// protected void lnkSave_Click(object sender, System.EventArgs e) { UpdatePanel teest = this.FindControl("UpdatePanel1") as UpdatePanel; Control test2 = teest.ContentTemplateContainer.FindControl("ctl09") as Control; temp1 test3 = test2.FindControl("TestMe") as temp1; string maybe = test3.Col1TopTitle; } Here I don't understand what it's telling me. for "par" I get "ctl09" and I have no idea how I am supposed to find this control. temp1.ascx.cs protected void Page_Load(object sender, EventArgs e) { string ppp = this.ID; string par = this.Parent.ID; }

    Read the article

  • .NET Framework generates strange DCOM error

    - by Anders Oestergaard Jensen
    Hello, I am creating a simple application that enables merging of key-value pairs fields in a Word and/or Excel document. Until this day, the application has worked out just fine. I am using the latest version of .NET Framework 4.0 (since it provides a nice wrapper API for Interop). My sample merging method looks like this: public byte[] ProcessWordDocument(string path, List<KeyValuePair<string, string>> kvs) { logger.InfoFormat("ProcessWordDocument: path = {0}", path); var localWordapp = new Word.Application(); localWordapp.Visible = false; Word.Document doc = null; try { doc = localWordapp.Documents.Open(path, ReadOnly: false); logger.Debug("Executing Find->Replace..."); foreach (Word.Range r in doc.StoryRanges) { foreach (KeyValuePair<string, string> kv in kvs) { r.Find.Execute(Replace: Word.WdReplace.wdReplaceAll, FindText: kv.Key, ReplaceWith: kv.Value, Wrap: Word.WdFindWrap.wdFindContinue); } } logger.Debug("Done! Saving document and cleaning up"); doc.Save(); doc.Close(); System.Runtime.InteropServices.Marshal.ReleaseComObject(doc); localWordapp.Quit(); System.Runtime.InteropServices.Marshal.ReleaseComObject(localWordapp); logger.Debug("Done."); return System.IO.File.ReadAllBytes(path); } catch (Exception ex) { // Logging... // doc.Close(); if (doc != null) { doc.Close(); System.Runtime.InteropServices.Marshal.ReleaseComObject(doc); } localWordapp.Quit(); System.Runtime.InteropServices.Marshal.ReleaseComObject(localWordapp); throw; } } The above C# snippet has worked all fine (compiled and deployed unto a Windows Server 2008 x64) with latest updates installed. But now, suddenly, I get the following strange error: System.Runtime.InteropServices.COMException (0x80080005): Retrieving the COM class factory for component with CLSID {000209FF-0000-0000-C000-000000000046} failed due to the following error: 80080005 Server execution failed (Exception from HRESULT: 0x80080005 (CO_E_SERVER_EXEC_FAILURE)). at System.RuntimeTypeHandle.CreateInstance(RuntimeType type, Boolean publicOnly, Boolean noCheck, Boolean& canBeCached, RuntimeMethodHandleInternal& ctor, Boolean& bNeedSecurityCheck) at System.RuntimeType.CreateInstanceSlow(Boolean publicOnly, Boolean skipCheckThis, Boolean fillCache) at System.RuntimeType.CreateInstanceDefaultCtor(Boolean publicOnly, Boolean skipVisibilityChecks, Boolean skipCheckThis, Boolean fillCache) at System.Activator.CreateInstance(Type type, Boolean nonPublic) at Meeho.Integration.OfficeHelper.ProcessWordDocument(String path, List`1 kvs) in C:\meeho\src\webservices\Meeho.Integration\OfficeHelper.cs:line 30 at Meeho.IntegrationService.ConvertDocument(Byte[] template, String ext, String[] fields, String[] values) in C:\meeho\src\webservices\MeehoService\IntegrationService.asmx.cs:line 49 -- I googled the COM error, but it returns nothing of particular value. I even gave the right permissions for the COM dll's using mmc -32, where I allocated the Word and Excel documents respectively and set the execution rights to the Administrator. I could not, however, locate the dll's by the exact COM CLSID given above. Very frustrating. Please, please, please help me as the application is currently pulled out of production. Anders EDIT: output from the Windows event log: Faulting application name: WINWORD.EXE, version: 12.0.6514.5000, time stamp: 0x4a89d533 Faulting module name: unknown, version: 0.0.0.0, time stamp: 0x00000000 Exception code: 0xc0000005 Fault offset: 0x00000000 Faulting process id: 0x720 Faulting application start time: 0x01cac571c4f82a7b Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\WINWORD.EXE Faulting module path: unknown Report Id: 041dd5f9-3165-11df-b96a-0025643cefe6 - 1000 2 100 0x80000000000000 2963 Application meeho3 - WINWORD.EXE 12.0.6514.5000 4a89d533 unknown 0.0.0.0 00000000 c0000005 00000000 720 01cac571c4f82a7b C:\Program Files (x86)\Microsoft Office\Office12\WINWORD.EXE unknown 041dd5f9-3165-11df-b96a-0025643cefe6

    Read the article

  • Parameter index is out of range

    - by czuroski
    Hello, I am getting the following error when trying to update an object using nhibernate. I am attempting to update a field which is a foreign key. Any thoughts why I might be getting this error? I can't figure it out from that error and my log4net log doesn't give any hints either. Thanks System.IndexOutOfRangeException was unhandled by user code Message="Parameter index is out of range." Source="MySql.Data" StackTrace: at MySql.Data.MySqlClient.MySqlParameterCollection.CheckIndex(Int32 index) at MySql.Data.MySqlClient.MySqlParameterCollection.GetParameter(Int32 index) at System.Data.Common.DbParameterCollection.System.Collections.IList.get_Item(Int32 index) at NHibernate.Type.Int32Type.Set(IDbCommand rs, Object value, Int32 index) at NHibernate.Type.NullableType.NullSafeSet(IDbCommand cmd, Object value, Int32 index) at NHibernate.Type.NullableType.NullSafeSet(IDbCommand st, Object value, Int32 index, ISessionImplementor session) at NHibernate.Persister.Entity.AbstractEntityPersister.Dehydrate(Object id, Object[] fields, Object rowId, Boolean[] includeProperty, Boolean[][] includeColumns, Int32 table, IDbCommand statement, ISessionImplementor session, Int32 index) at NHibernate.Persister.Entity.AbstractEntityPersister.Update(Object id, Object[] fields, Object[] oldFields, Object rowId, Boolean[] includeProperty, Int32 j, Object oldVersion, Object obj, SqlCommandInfo sql, ISessionImplementor session) at NHibernate.Persister.Entity.AbstractEntityPersister.UpdateOrInsert(Object id, Object[] fields, Object[] oldFields, Object rowId, Boolean[] includeProperty, Int32 j, Object oldVersion, Object obj, SqlCommandInfo sql, ISessionImplementor session) at NHibernate.Persister.Entity.AbstractEntityPersister.Update(Object id, Object[] fields, Int32[] dirtyFields, Boolean hasDirtyCollection, Object[] oldFields, Object oldVersion, Object obj, Object rowId, ISessionImplementor session) at NHibernate.Action.EntityUpdateAction.Execute() at NHibernate.Engine.ActionQueue.Execute(IExecutable executable) at NHibernate.Engine.ActionQueue.ExecuteActions(IList list) at NHibernate.Engine.ActionQueue.ExecuteActions() at NHibernate.Event.Default.AbstractFlushingEventListener.PerformExecutions(IEventSource session) at NHibernate.Event.Default.DefaultFlushEventListener.OnFlush(FlushEvent event) at NHibernate.Impl.SessionImpl.Flush() at NHibernate.Transaction.AdoTransaction.Commit() at DataAccessLayer.NHibernateDataProvider.UpdateItem_temp(items_temp item_temp) in C:\Documents and Settings\user\My Documents\Visual Studio 2008\Projects\mySolution\DataAccessLayer\NHibernateDataProvider.cs:line 225 at InventoryDataClean.Controllers.ImportController.Edit(Int32 id, FormCollection formValues) in C:\Documents and Settings\user\My Documents\Visual Studio 2008\Projects\mySolution\InventoryDataClean\Controllers\ImportController.cs:line 101 at lambda_method(ExecutionScope , ControllerBase , Object[] ) at System.Web.Mvc.ActionMethodDispatcher.Execute(ControllerBase controller, Object[] parameters) at System.Web.Mvc.ReflectedActionDescriptor.Execute(ControllerContext controllerContext, IDictionary`2 parameters) at System.Web.Mvc.ControllerActionInvoker.InvokeActionMethod(ControllerContext controllerContext, ActionDescriptor actionDescriptor, IDictionary`2 parameters) at System.Web.Mvc.ControllerActionInvoker.<>c__DisplayClassa.<InvokeActionMethodWithFilters>b__7() at System.Web.Mvc.ControllerActionInvoker.InvokeActionMethodFilter(IActionFilter filter, ActionExecutingContext preContext, Func`1 continuation) InnerException: Here is my item mapping - <?xml version="1.0" encoding="utf-8" ?> <hibernate-mapping xmlns="urn:nhibernate-mapping-2.2" assembly="DataTransfer" namespace="DataTransfer"> <class name="DataTransfer.items_temp, DataTransfer" table="items_temp"> <id name="id" unsaved-value="any" > <generator class="assigned"/> </id> <property name="assetid"/> <property name="description"/> <property name="caretaker"/> <property name="category"/> <property name="status" /> <property name="vendor" /> <many-to-one name="statusName" class="status" column="status" /> </class> </hibernate-mapping> Here is my status mapping - <?xml version="1.0" encoding="utf-8" ?> <hibernate-mapping xmlns="urn:nhibernate-mapping-2.2" assembly="DataTransfer" namespace="DataTransfer"> <class name="DataTransfer.status, DataTransfer" table="status"> <id name="id" unsaved-value="0"> <generator class="assigned"/> </id> <property name="name"/> <property name="def"/> </class> </hibernate-mapping> and here is my update function - public void UpdateItem_temp(items_temp item_temp) { ITransaction t = _session.BeginTransaction(); try { _session.SaveOrUpdate(item_temp); t.Commit(); } catch (Exception) { t.Rollback(); throw; } finally { t.Dispose(); } }

    Read the article

< Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >