Search Results

Search found 19125 results on 765 pages for 'hard disk'.

Page 94/765 | < Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >

  • Wear and tear on server hard drive from filesystem polling by PHP script

    - by jackie
    So I'm working on a discussion platform, and various clients will visit http://host/thread.php, which will render the discussion thread to date in addition to a form to submit a new post. When a new post is submitted, I would like all of the other clients with browser windows open to have it appear in near-real-time. One of the constraints of my script is that it may not use a DBMS and it must stay in the filesystem. Additionally, I can't use any PECL/PEAR extensions like inotify or anything like that for IPC. The flow will look like this: Client A requests thread.php and the thread is so far empty, but nonetheless it opens a Server-Side Event at eventPusher.php. Client B does the same. Client A fills out a post in the form and and submits (POSTs) it to subHandler.php. ??? (subHandler stores the new submission into the main thread storefile which gets read from when a fresh, new client requests thread.php, in addition to somehow signalling to the continually-running eventPusher event-source that a new comment was posted and that it should echo the event-json to the client. How, exactly, it will send this signal I'm yet unsure of, but there are a few options that I've thought of -- this is the crux of the question, so see below for more clarification) eventPusher.php happily pushes the new event to the client and it shows up soon after it was originally submitted on all clients who have the page open's screens. Now for the #4 missing-link mystery-step, I see a few problems. I mean, either way, eventPusher is gonna be doing a while loop of some sort -- it's gonna be polling something, I think that much is clear. (If that's a bad assumption please do let me know.) Now, the simplest way would be subHandler gets invoked on the form submission, writes it to the main store in addition to newComments.xml, then exits without doing anything else. Then eventPusher checks in newComments.xml every X seconds (by the way, what would be a reasonable time interval here?) and if it finds something then it emits an event to the client. Now, my fear with this is that the server's hard drive will have to constantly start spinning up. Maybe this isn't the case, perhaps it would just get cached in RAM and the linux kernel would take care of this transparently such that filesystem access doesn't actually engage the device because the kernel knows that that particular file hasn't changed since last read. * idea #2: I have no idea how to go about this, but perhaps there is a variable scope that gets stored in general RAM on the system which can be read by any process. Like if we mega-exported a bash variable so that $new_post is normally false but it gets toggled to true by subHandler, and then back to flase once it's pushed to the client. I doubt there's such a variable scope in PHP directly, but I struggle with the concept of variable scope, I just can't seem to understand it no matter what I read on it. * idea #3: eventPusher queries ps in its whileloop for another instance of itself. If there's not another eventPusher active then it's highly unlikely that new comments will be getting submitted. It's okay if this only works =90% of the time, it doesn't need to be completely foolproof. * idea #4: eventPusher queries DMESG to see if that file's been written to recently. So to sum everything up, I need to have inter-php-script-communication in near-real-time that will work on a standard mod_php shared hosting setup without any elevated privileges, PHP addon modules, or other system adjustments that can't be done from the PHP script itself at runtime. With*out* spinning up the drive more than a few times. No SQL servers either. Apologies if my english isn't the best, I'm still trying to improve on it.

    Read the article

  • Write-error on swap-device, Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK

    - by Jan
    My root server at 1&1 was unresponsive on HTTP and SSH, so I logged into the serial console . It flooded my connection with endless error messages like quoted below. I initiated a reboot and now everything seems to work properly. After googling, I installed smartctl and ran a short self test, which told me the device was healthy. Is this likely a disk failure soon to happen or could it be just some program going wild? I assume, the swap device could also grow full when huge amounts of memory get consumed by a buggy program? How can I find out for sure? The sever was already unresponsive a week ago when I just restarted it without proper investigation. The server is running on CentOS. Write-error on swap-device (8:16:8351055) Write-error on swap-device (8:16:8351063) Write-error on swap-device (8:16:8351071) Write-error on swap-device (8:16:8351079) Write-error on swap-device (8:16:8351087) Write-error on swap-device (8:16:8351095) Write-error on swap-device (8:16:8351103) Write-error on swap-device (8:16:8351111) Write-error on swap-device (8:16:8351119) Write-error on swap-device (8:16:8351127) Write-error on swap-device (8:16:8351135) Write-error on swap-device (8:16:8351143) Write-error on swap-device (8:16:8351151) Write-error on swap-device (8:16:8351159) Write-error on swap-device (8:16:8351167) Write-error on swap-device (8:16:8351175) Write-error on swap-device (8:16:8351183) Write-error on swap-device (8:16:8351191) sd 1:0:0:0: [sdb] Unhandled error code sd 1:0:0:0: [sdb] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK sd 1:0:0:0: [sdb] CDB: Write(10): 2a 00 00 9c 00 ef 00 00 08 00 end_request: I/O error, dev sdb, sector 10223855 Write-error on swap-device (8:16:10223863) sd 1:0:0:0: [sdb] Unhandled error code sd 1:0:0:0: [sdb] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK sd 1:0:0:0: [sdb] CDB: Write(10): 2a 00 00 9c 0e 97 00 00 10 00 end_request: I/O error, dev sdb, sector 10227351 Write-error on swap-device (8:16:10227359) Write-error on swap-device (8:16:10227367) sd 1:0:0:0: [sdb] Unhandled error code sd 1:0:0:0: [sdb] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK sd 1:0:0:0: [sdb] CDB: Write(10): 2a 00 00 9c b0 1f 00 00 10 00 end_request: I/O error, dev sdb, sector 10268703 Write-error on swap-device (8:16:10268711) Write-error on swap-device (8:16:10268719) sd 1:0:0:0: [sdb] Unhandled error code sd 1:0:0:0: [sdb] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK sd 1:0:0:0: [sdb] CDB: Write(10): 2a 00 00 a0 84 7f 00 00 08 00 end_request: I/O error, dev sdb, sector 10519679 Write-error on swap-device (8:16:10519687) sd 1:0:0:0: [sdb] Unhandled error code sd 1:0:0:0: [sdb] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK sd 1:0:0:0: [sdb] CDB: Write(10): 2a 00 00 a7 26 af 00 04 00 00 end_request: I/O error, dev sdb, sector 10954415 Write-error on swap-device (8:16:10954423) Write-error on swap-device (8:16:10954431) Write-error on swap-device (8:16:10954439) Write-error on swap-device (8:16:10954447) Write-error on swap-device (8:16:10954455) Write-error on swap-device (8:16:10954463) Write-error on swap-device (8:16:10954471) Write-error on swap-device (8:16:10954479) Write-error on swap-device (8:16:10954487) Write-error on swap-device (8:16:10954495) Write-error on swap-device (8:16:10954503) Write-error on swap-device (8:16:10954511) Write-error on swap-device (8:16:10954519) Write-error on swap-device (8:16:10954527) Write-error on swap-device (8:16:10954535) Write-error on swap-device (8:16:10954543) Write-error on swap-device (8:16:10954551) Write-error on swap-device (8:16:10954559) Write-error on swap-device (8:16:10954567) Write-error on swap-device (8:16:10954575) Write-error on swap-device (8:16:10954583) Write-error on swap-device (8:16:10954591) Write-error on swap-device (8:16:10954599) Write-error on swap-device (8:16:10954607) Write-error on swap-device (8:16:10954615) Write-error on swap-device (8:16:10954623) Write-error on swap-device (8:16:10954631) Write-error on swap-device (8:16:10954639) Write-error on swap-device (8:16:10954647) Write-error on swap-device (8:16:10954655) Write-error on swap-device (8:16:10954663) Write-error on swap-device (8:16:10954671) Write-error on swap-device (8:16:10954679) Write-error on swap-device (8:16:10954687) Write-error on swap-device (8:16:10954695) Write-error on swap-device (8:16:10954703) Write-error on swap-device (8:16:10954711) Write-error on swap-device (8:16:10954719) Write-error on swap-device (8:16:10954727) Write-error on swap-device (8:16:10954735) Write-error on swap-device (8:16:10954743) Write-error on swap-device (8:16:10954751) Write-error on swap-device (8:16:10954759) Write-error on swap-device (8:16:10954767) Write-error on swap-device (8:16:10954775) Write-error on swap-device (8:16:10954783) Write-error on swap-device (8:16:10954791) Write-error on swap-device (8:16:10954799) Write-error on swap-device (8:16:10954807) Write-error on swap-device (8:16:10954815) Write-error on swap-device (8:16:10954823) Write-error on swap-device (8:16:10954831) Write-error on swap-device (8:16:10954839) Write-error on swap-device (8:16:10954847) Write-error on swap-device (8:16:10954855) Write-error on swap-device (8:16:10954863) Write-error on swap-device (8:16:10954871) Write-error on swap-device (8:16:10954879) Write-error on swap-device (8:16:10954887) Write-error on swap-device (8:16:10954895) Write-error on swap-device (8:16:10954903) Write-error on swap-device (8:16:10954911) Write-error on swap-device (8:16:10954919) Write-error on swap-device (8:16:10954927) Write-error on swap-device (8:16:10954935) Write-error on swap-device (8:16:10954943) Write-error on swap-device (8:16:10954951) Write-error on swap-device (8:16:10954959) Write-error on swap-device (8:16:10954967) Write-error on swap-device (8:16:10954975) Write-error on swap-device (8:16:10954983) Write-error on swap-device (8:16:10954991) Write-error on swap-device (8:16:10954999) Write-error on swap-device (8:16:10955007) Write-error on swap-device (8:16:10955015) Write-error on swap-device (8:16:10955023) Write-error on swap-device (8:16:10955031) Write-error on swap-device (8:16:10955039) Write-error on swap-device (8:16:10955047) Write-error on swap-device (8:16:10955055) Write-error on swap-device (8:16:10955063) Write-error on swap-device (8:16:10955071) Write-error on swap-device (8:16:10955079) Write-error on swap-device (8:16:10955087) Write-error on swap-device (8:16:10955095) Write-error on swap-device (8:16:10955103) Write-error on swap-device (8:16:10955111) Write-error on swap-device (8:16:10955119) Write-error on swap-device (8:16:10955127) Write-error on swap-device (8:16:10955135) Write-error on swap-device (8:16:10955143) Write-error on swap-device (8:16:10955151) Write-error on swap-device (8:16:10955159) Write-error on swap-device (8:16:10955167) Write-error on swap-device (8:16:10955175) Write-error on swap-device (8:16:10955183)

    Read the article

  • Event on SQL Server 2008 Disk IO and the new Complex Event Processing (StreamInsight) feature in R2

    - by tonyrogerson
    Allan Mitchell and myself are doing a double act, Allan is becoming one of the leading guys in the UK on StreamInsight and will give an introduction to this new exciting technology; on top of that I'll being talking about SQL Server Disk IO - well, "Disk" might not be relevant anymore because I'll be talking about SSD and IOFusion - basically I'll be talking about the underpinnings - making sure you understand and get it right, how to monitor etc... If you've any specific problems or questions just ping me an email [email protected]. To register for the event see: http://sqlserverfaq.com/events/217/SQL-Server-and-Disk-IO-File-GroupsFiles-SSDs-FusionIO-InRAM-DBs-Fragmentation-Tony-Rogerson-Complex-Event-Processing-Allan-Mitchell.aspx 18:15 SQL Server and Disk IOTony Rogerson, SQL Server MVPTony's Blog; Tony on TwitterIn this session Tony will talk about RAID levels, how SQL server writes to and reads from disk, the effect SSD has and will talk about other options for throughput enhancement like Fusion IO. He will look at the effect fragmentation has and how to minimise the impact, he will look at the File structure of a database and talk about what benefits multiple files and file groups bring. We will also touch on Database Mirroring and the effect that has on throughput, how to get a feeling for the throughput you should expect.19:15 Break19:45 Complex Event Processing (CEP)Allan Mitchell, SQL Server MVPhttp://sqlis.com/sqlisStreamInsight is Microsoft’s first foray into the world of Complex Event Processing (CEP) and Event Stream Processing (ESP).  In this session I want to show an introduction to this technology.  I will show how and why it is useful.  I will get us used to some new terminology but best of all I will show just how easy it is to start building your first CEP/ESP application.

    Read the article

  • What kind of things are easy in Haskell and hard in Scala, and vice versa?

    - by Daniel C. Sobral
    There has been some intermingling of Scala and Haskell communities, and I have noticed now and then people commenting on stuff that's supposed to be easy in Haskell and hard and Scala. Less often (maybe because I read Scala questions, not Haskell ones), I see someone mentioning that something in Scala is easier than in Haskell. So. I'd like to know from people who are knowledgeable in both what kind of things are easy in Haskell and hard in Scala, and, conversely, what kind of things are easy in Scala and hard in Haskell.

    Read the article

  • How can I prevent [flush-8:16] and [jbd2/sdb2-8] from causing GUI unresponsiveness?

    - by ændrük
    Approximately twice a week, the entire graphical interface will lock up for about 10-20 seconds without warning while I am doing simple tasks such as browsing the web or writing a paper. When this happens, GUI elements do not respond to mouse or keyboard input, and the System Monitor applet displays 100% IOWait processor usage. Today, I finally happened to have GNOME Terminal already open when the problem started. Despite other applications such as Google Chrome, Firefox, GNOME Do, and GNOME Panel being unresponsive, the terminal was usable. I ran iotop and observed that commands named [flush-8:16] and [jbd2/sdb2-8] were alternately using 99.99% IO. What are these, and how can I prevent them from causing GUI unresponsiveness? Details $ mount | grep ^/dev /dev/sda1 on / type ext4 (rw,noatime,discard,errors=remount-ro,commit=0) /dev/sdb2 on /home type ext4 (rw,commit=0) /dev/sda is an OCZ-VERTEX2 and /dev/sdb is a WD10EARS. Here is dumpe2fs /dev/sdb2, if it's relevant.

    Read the article

  • Skipping scheduled self-tests and predicting drive EOL

    - by Steve Madsen
    For a few weeks now, smartd has been reporting that it is skipping some of its scheduled self-tests on the weekends: Apr 24 18:29:32 calvin smartd[4758]: Device: /dev/sda, skip scheduled Offline Immediate Test; 40% remaining of current Self-Test. Apr 24 18:29:33 calvin smartd[4758]: Device: /dev/sdb, skip scheduled Offline Immediate Test; 50% remaining of current Self-Test. The drives in this RAID-1 array are set to run an offline test four times a day, a short self-test at 2am every day, and a long self-test on Saturdays at 2am. For some reason, it looks like the long self-test is taking longer, causing the other scheduled tests to be skipped. First question: is this a sign of likely drive failure? Then today, smartd reported that a self-test failed. Here is the output of smartctl -a /dev/sdb: smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3250823AS Serial Number: 3ND1GNBC Firmware Version: 3.03 User Capacity: 250,059,350,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Apr 25 13:15:34 2010 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 047 039 006 Pre-fail Always - 168450357 3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 33 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 9 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 654745480 9 Power_On_Hours 0x0032 055 055 000 Old_age Always - 40141 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 51 194 Temperature_Celsius 0x0022 037 062 000 Old_age Always - 37 (0 17 0 0) 195 Hardware_ECC_Recovered 0x001a 047 039 000 Old_age Always - 168450357 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 40131 - # 2 Extended offline Completed: read failure 30% 40129 379795511 # 3 Short offline Completed without error 00% 40084 - # 4 Short offline Completed without error 00% 40060 - # 5 Short offline Completed without error 00% 40036 - # 6 Short offline Completed without error 00% 40013 - # 7 Short offline Completed without error 00% 39990 - # 8 Extended offline Completed without error 00% 39977 - # 9 Short offline Completed without error 00% 39919 - #10 Short offline Completed without error 00% 39895 - #11 Short offline Completed without error 00% 39872 - #12 Short offline Completed without error 00% 39848 - #13 Short offline Completed without error 00% 39824 - #14 Short offline Completed without error 00% 39801 - #15 Extended offline Completed without error 00% 39789 - #16 Short offline Completed without error 00% 39754 - #17 Short offline Completed without error 00% 39732 - #18 Short offline Completed without error 00% 39707 - #19 Short offline Completed without error 00% 39683 - #20 Short offline Completed without error 00% 39660 - #21 Short offline Completed without error 00% 39636 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. Given that this drive is about 4.5 years old, I am probably tempting fate by keeping it in service. SMART doesn't seem to get much respect as a reliable way to predict drive failure. What else can I use to get an early indication of drive failure?

    Read the article

  • How do I free up more space in /boot?

    - by user6722
    My /boot partition is nearly full and I get a warning every time I reboot my system. I already deleted old kernel packages (linux-headers...), actually I did that to install a newer kernel version that came with the automatic updates. After installing that new version, the partition is nearly full again. So what else can I delete? Are there some other files associated to the old kernel images? Here is a list of files that are on my /boot partition: :~$ ls /boot/ abi-2.6.31-21-generic lost+found abi-2.6.32-25-generic memtest86+.bin abi-2.6.38-10-generic memtest86+_multiboot.bin abi-2.6.38-11-generic System.map-2.6.31-21-generic abi-2.6.38-12-generic System.map-2.6.32-25-generic abi-2.6.38-8-generic System.map-2.6.38-10-generic abi-3.0.0-12-generic System.map-2.6.38-11-generic abi-3.0.0-13-generic System.map-2.6.38-12-generic abi-3.0.0-14-generic System.map-2.6.38-8-generic boot System.map-3.0.0-12-generic config-2.6.31-21-generic System.map-3.0.0-13-generic config-2.6.32-25-generic System.map-3.0.0-14-generic config-2.6.38-10-generic vmcoreinfo-2.6.31-21-generic config-2.6.38-11-generic vmcoreinfo-2.6.32-25-generic config-2.6.38-12-generic vmcoreinfo-2.6.38-10-generic config-2.6.38-8-generic vmcoreinfo-2.6.38-11-generic config-3.0.0-12-generic vmcoreinfo-2.6.38-12-generic config-3.0.0-13-generic vmcoreinfo-2.6.38-8-generic config-3.0.0-14-generic vmcoreinfo-3.0.0-12-generic extlinux vmcoreinfo-3.0.0-13-generic grub vmcoreinfo-3.0.0-14-generic initrd.img-2.6.31-21-generic vmlinuz-2.6.31-21-generic initrd.img-2.6.32-25-generic vmlinuz-2.6.32-25-generic initrd.img-2.6.38-10-generic vmlinuz-2.6.38-10-generic initrd.img-2.6.38-11-generic vmlinuz-2.6.38-11-generic initrd.img-2.6.38-12-generic vmlinuz-2.6.38-12-generic initrd.img-2.6.38-8-generic vmlinuz-2.6.38-8-generic initrd.img-3.0.0-12-generic vmlinuz-3.0.0-12-generic initrd.img-3.0.0-13-generic vmlinuz-3.0.0-13-generic initrd.img-3.0.0-14-generic vmlinuz-3.0.0-14-generic Currently, I'm using the 3.0.0-14-generic kernel.

    Read the article

  • My linux server takes more than an hour to boot. Suggestions?

    - by jamieb
    I am building a CentOS 5.4 system that boots off a compact flash card using a card reader that emulates an IDE drive. It literally takes about an hour to boot. The ultra-slow part occurs when Grub is loading the kernel. Once that's done, the rest of the boot process only takes about a minute to get to a login prompt. Does anyone have any suggestions? I suspect that it may have to do with UDMA. Everything IDE-related in my BIOS seems to checkout. The read performance hdparm is telling me 1.77 MB/s. Ouch! (But even at that rate, it still shouldn't take an hour to decompress and load the kernel) [root@server ~]# hdparm -tT /dev/hdc /dev/hdc: Timing cached reads: 2444 MB in 2.00 seconds = 1222.04 MB/sec Timing buffered disk reads: 6 MB in 3.39 seconds = 1.77 MB/sec Trying to enable DMA is a no-go though: [root@server ~]# hdparm -d1 /dev/hdc /dev/hdc: setting using_dma to 1 (on) HDIO_SET_DMA failed: Operation not permitted using_dma = 0 (off) Here's some command outputs that might help: System [root@server ~]# uname -a Linux server.localdomain 2.6.18-164.el5xen #1 SMP Thu Sep 3 04:47:32 EDT 2009 i686 i686 i386 GNU/Linux PCI info: [root@server ~]# lspci -v 00:00.0 Host bridge: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub (rev 02) Subsystem: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub Flags: bus master, fast devsel, latency 0 Capabilities: [e0] Vendor Specific Information 00:02.0 VGA compatible controller: Intel Corporation 82945G/GZ Integrated Graphics Controller (rev 02) (prog-if 00 [VGA controller]) Subsystem: Intel Corporation 82945G/GZ Integrated Graphics Controller Flags: bus master, fast devsel, latency 0, IRQ 10 Memory at fdf00000 (32-bit, non-prefetchable) [size=512K] I/O ports at ff00 [size=8] Memory at d0000000 (32-bit, prefetchable) [size=256M] Memory at fdf80000 (32-bit, non-prefetchable) [size=256K] Capabilities: [90] Message Signalled Interrupts: 64bit- Queue=0/0 Enable- Capabilities: [d0] Power Management version 2 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 Flags: bus master, medium devsel, latency 0, IRQ 16 I/O ports at fe00 [size=32] 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 Flags: bus master, medium devsel, latency 0, IRQ 17 I/O ports at fd00 [size=32] 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 Flags: bus master, medium devsel, latency 0, IRQ 18 I/O ports at fc00 [size=32] 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01) (prog-if 00 [UHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 Flags: bus master, medium devsel, latency 0, IRQ 19 I/O ports at fb00 [size=32] 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01) (prog-if 20 [EHCI]) Subsystem: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller Flags: bus master, medium devsel, latency 0, IRQ 16 Memory at fdfff000 (32-bit, non-prefetchable) [size=1K] Capabilities: [50] Power Management version 2 Capabilities: [58] Debug port 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1) (prog-if 01 [Subtractive decode]) Flags: bus master, fast devsel, latency 0 Bus: primary=00, secondary=01, subordinate=01, sec-latency=32 I/O behind bridge: 0000d000-0000dfff Memory behind bridge: fde00000-fdefffff Prefetchable memory behind bridge: 00000000fdd00000-00000000fdd00000 Capabilities: [50] #0d [0000] 00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01) Subsystem: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge Flags: bus master, medium devsel, latency 0 Capabilities: [e0] Vendor Specific Information 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01) (prog-if 80 [Master]) Subsystem: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller Flags: bus master, 66MHz, medium devsel, latency 0, IRQ 17 I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at <unassigned> I/O ports at f800 [size=16] Capabilities: [70] Power Management version 2 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 01) Subsystem: Intel Corporation 82801G (ICH7 Family) SMBus Controller Flags: medium devsel, IRQ 17 I/O ports at 0500 [size=32] 01:04.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 18 I/O ports at de00 [size=256] Memory at fdeff000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 01:06.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 17 I/O ports at dc00 [size=256] Memory at fdefe000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 01:07.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) Subsystem: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ Flags: bus master, medium devsel, latency 32, IRQ 19 I/O ports at da00 [size=256] Memory at fdefd000 (32-bit, non-prefetchable) [size=256] Capabilities: [50] Power Management version 2 hdparm ouput: [root@server ~]# hdparm /dev/hdc /dev/hdc: multcount = 0 (off) IO_support = 0 (default 16-bit) unmaskirq = 0 (off) using_dma = 0 (off) keepsettings = 0 (off) readonly = 0 (off) readahead = 256 (on) geometry = 8146/16/63, sectors = 8211168, start = 0 [root@server ~]# hdparm -I /dev/hdc /dev/hdc: ATA device, with non-removable media Model Number: InnoDisk Corp. - iCF4000 4GB Serial Number: 20091023AACA70000753 Firmware Revision: 081107 Standards: Supported: 5 Likely used: 6 Configuration: Logical max current cylinders 8146 8146 heads 16 16 sectors/track 63 63 -- CHS current addressable sectors: 8211168 LBA user addressable sectors: 8211168 device size with M = 1024*1024: 4009 MBytes device size with M = 1000*1000: 4204 MBytes (4 GB) Capabilities: LBA, IORDY(can be disabled) Standby timer values: spec'd by Vendor R/W multiple sector transfer: Max = 2 Current = 2 DMA: mdma0 mdma1 mdma2 udma0 udma1 *udma2 udma3 udma4 Cycle time: min=120ns recommended=120ns PIO: pio0 pio1 pio2 pio3 pio4 Cycle time: no flow control=120ns IORDY flow control=120ns Commands/features: Enabled Supported: * Power Management feature set * WRITE_BUFFER command * READ_BUFFER command * NOP cmd * CFA feature set * Mandatory FLUSH_CACHE HW reset results: CBLID- above Vih Device num = 0 CFA power mode 1: enabled and required by some commands Maximum current = 100ma Checksum: correct

    Read the article

  • Cannot delete .Trash-503 directory, returns a $RECYCLE.BIN.trashinfo: Input/output error

    - by Parto
    I cannot delete .Trash-503 folder via GUI or terminal, it returns a $RECYCLE.BIN.trashinfo: Input/output error Not even sudo rm -r or even a simple ls works in that trash directory. Check terminal output below: subroot@subroot:~$ cd /media/xxxxx/ subroot@subroot:/media/xxxxx$ rm .Trash-503/ rm: cannot remove `.Trash-503/': Is a directory subroot@subroot:/media/xxxxx$ rm -r .Trash-503/ rm: cannot remove `.Trash-503/info/$RECYCLE.BIN.trashinfo': Input/output error rm: cannot remove `.Trash-503/info/found.000.trashinfo': Input/output error rm: cannot remove `.Trash-503/info': Directory not empty subroot@subroot:/media/xxxxx$ sudo rm -r .Trash-503/ [sudo] password for subroot: rm: cannot remove `.Trash-503/info/$RECYCLE.BIN.trashinfo': Input/output error rm: cannot remove `.Trash-503/info/found.000.trashinfo': Input/output error subroot@subroot:/media/xxxxx$ cd .Trash-503/ subroot@subroot:/media/xxxxx/.Trash-503$ ls info subroot@subroot:/media/xxxxx/.Trash-503$ cd info/ subroot@subroot:/media/xxxxx/.Trash-503/info$ ls ls: cannot access $RECYCLE.BIN.trashinfo: Input/output error ls: cannot access found.000.trashinfo: Input/output error found.000.trashinfo $RECYCLE.BIN.trashinfo subroot@subroot:/media/xxxxx/.Trash-503/info$ What's going on here and how can I delete this folder? EDIT I tried checking and repairing the partition using gparted only to get this error message: ERROR: Filesystem check failed! ERROR: 264 clusters are referenced multiple times. NTFS is inconsistent. Run chkdsk /f on Windows then reboot it TWICE! The usage of the /f parameter is very IMPORTANT! No modification was and will be made to NTFS by this software until it gets repaired. I don't have windows installed, how can I run chkdsk /f from ubuntu?

    Read the article

  • Where did my free space go?

    - by Ari B. Friedman
    I have a storage drive (2TB) and an OS drive (90GB SSD). I've run out of space on the OS drive: /$ df -h Filesystem Size Used Avail Use% Mounted on /dev/sdb1 72G 72G 0 100% / udev 5.9G 12K 5.9G 1% /dev tmpfs 2.4G 1.2M 2.4G 1% /run none 5.0M 0 5.0M 0% /run/lock none 5.9G 428K 5.9G 1% /run/shm /dev/sda1 1.9T 639G 1.2T 37% /media/StorageDrive So be it. But when I attempt to figure out where the space has gone, I cannot find it anything remotely approaching the capacity of the drive: /$ sudo du -h -d 1 du: cannot access `./media/StorageDrive/home/ari/.gvfs': Permission denied 675G ./media 2.3G ./var 0 ./proc 7.0M ./tmp 27M ./boot 4.0K ./lib64 12K ./dev 44M ./home 16K ./lost+found 8.0M ./sbin 223M ./lib 4.0K ./selinux 1.4M ./run 140K ./root 8.8M ./bin 4.0K ./mnt 38M ./etc 8.0K ./srv 4.8G ./usr 65M ./opt 0 ./sys 682G . Note the difference between the total (682G) and the mounted drives in /media (675G) is only about 9G. How are 72G being used? Where is this dark matter hiding?

    Read the article

  • Annual Review: what hard data should a developer bring?

    - by sunpech
    Many companies have annual reviews for their employees. I've heard that it's generally a good idea to muster up some hard data to analyze and bring to the review. The better the data, the better the chances to help support a promotion or raise. What I mean by hard data, are tangible numbers-- something that can be measured and/or calculated. Obviously data that a developer would have access to. Something intangible would be how beautiful the code a developer has written. I think this would be very hard to measure, nor would upper management care for it. My question is: For a software developer, what kind of hard data should be analyzed and brought to a review to help highlight good work that was done? An example I've been given in the past: The support tickets produced by each project a developer was involved in. Are the numbers low? Are the rate per month getting lower? Etc.

    Read the article

  • /tmp shows 690 Mb full, actual size 72 K, Why?

    - by Ankit
    Why is /tmp diretory on my system showing 690 Mb full, whereas du -sh /tmp shows only 72K full. drwxrwxrwt 2 lightdm lightdm 4096 Aug 29 21:49 at-spi2 drwx------ 2 ankit ankit 4096 Aug 29 21:50 keyring-0JTfoY drwx------ 2 ankit ankit 4096 Aug 29 21:44 keyring-rChLLL drwx------ 2 root root 16384 Jul 22 02:10 lost+found drwx------ 2 ankit ankit 4096 Jan 1 1970 orbit-ankit drwx------ 2 lightdm lightdm 4096 Aug 29 21:50 pulse-2L9K88eMlGn7 drwx------ 2 root root 4096 Aug 29 21:44 pulse-PKdhtXMmr18n drwx------ 2 ankit ankit 4096 Aug 29 21:50 pulse-zR1TZUAZfmQW drwx------ 2 ankit ankit 4096 Aug 29 21:44 ssh-dlslOXOq2203 drwx------ 2 ankit ankit 4096 Aug 29 21:50 ssh-MrQQVRyy3316 -rw------- 1 ankit ankit 0 Aug 29 21:45 tmp0qnNG4 -rw------- 1 ankit ankit 0 Aug 29 21:50 tmpVvSMt6 -rw------- 1 ankit ankit 0 Aug 29 21:49 tmpy9Gadz -rw-rw-r-- 1 lightdm lightdm 0 Aug 29 21:44 unity_support_test.0 ankit@duster:/tmp$ df -h df: `/home/ankit/.gvfs': Transport endpoint is not connected Filesystem Size Used Avail Use% Mounted on /dev/sda1 79G 11G 65G 14% / udev 2.9G 4.0K 2.9G 1% /dev tmpfs 1.2G 868K 1.2G 1% /run none 5.0M 0 5.0M 0% /run/lock none 2.9G 220K 2.9G 1% /run/shm /dev/sda7 38G 690M 35G 2% /tmp /dev/sda5 93G 26G 63G 30% /home /dev/sda6 93G 1.6G 87G 2% /boot /dev/sda3 154G 69G 78G 48% /home/mount_150 ankit@duster:/tmp$ ankit@duster:/tmp$ ankit@duster:/tmp$ sudo du -sh /tmp/ 72K

    Read the article

  • NFS server generating "invalid extent" on EXT4 system disk?

    - by Stephen Winnall
    I have a server running Xen 4.1 with Oneiric in the dom0 and each of the 4 domUs. The system disks of the domUs are LVM2 volumes built on top of an mdadm RAID1. All the domU system disks are EXT4 and are created using snapshots of the same original template. 3 of them run perfectly, but one (called s-ub-02) keeps on being remounted read-only. A subsequent e2fsck results in a single "invalid extent" diagnosis: e2fsck 1.41.14 (22-Dec-2010) /dev/domu/s-ub-02-root contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Inode 525418 has an invalid extent (logical block 8959, invalid physical block 0, len 0) Clear<y>? yes Pass 2: Checking directory structure Pass 3: Checking directory connectivity Pass 4: Checking reference counts Pass 5: Checking group summary information /dev/domu/s-ub-02-root: 77757/655360 files (0.3% non-contiguous), 360592/2621440 blocks The console shows typically the following errors for the system disk (xvda2): [101980.903416] EXT4-fs error (device xvda2): ext4_ext_find_extent:732: inode #525418: comm apt-get: bad header/extent: invalid extent entries - magic f30a, entries 12, max 340(340), depth 0(0) [101980.903473] EXT4-fs (xvda2): Remounting filesystem read-only I have created new versions of the system disk. The same thing always happens. This, and the fact that the disk is ultimately on a RAID1, leads me to preclude a hardware disk error. The only obvious distinguishing feature of this domU is the presence of nfs-kernel-server, so I suspect that. Its exports file looks like this: /exports/users 192.168.0.0/255.255.248.0(rw,sync,no_subtree_check) /exports/media/music 192.168.0.0/255.255.248.0(rw,sync,no_subtree_check) /exports/media/pictures 192.168.0.0/255.255.248.0(rw,sync,no_subtree_check) /exports/opt 192.168.0.0/255.255.248.0(rw,sync,no_subtree_check) /exports/users and /exports/opt are LVM2 volumes from the same volume group as the system disk. /exports/media is an EXT2 volume. (There is an issue where clients see /exports/media/pictures as being a read-only volume, which I mention for completeness.) With the exception of the read-only problem, the NFS server appears to work correctly under light load for several hours before the "invalid extent" problem occurs. There are no helpful entries in /var/log. All of a sudden, no more files are written, so you can see when the disk was remounted read-only, but there is no indication of what the cause might be. Can anyone help me with this problem? Steve

    Read the article

  • How do you force Ubuntu to unmount a disk when you press the eject button on an optical drive?

    - by Michael Curran
    When upgrading my hardware, I also upgraded to Ubuntu 10.10. On my previous system (with 10.04 and earlier) when I ejected a disk from the optical drive, the subfolder in the /media directory was automatically removed. In my new 10.10 system, if I don't eject the disk using the "eject" command within the system, the disk remains mounted, even after a new disk is installed. The new drive is a Blu Ray drive, but I haven't noticed any other problems from it. Normally, this isn't a problem, but it makes installing applications that are spread over multiple CDs more difficult in many cases (i.e. Wine). Any advice?

    Read the article

  • How can I make an unmounted / unmountable NTFS disk not show up in the nautilus devices area?

    - by Dennis
    I have an idea that my /etc/fstab is a real mish-mash and I don't remember how it got that way, first of all it looks like this UUID=9EB80807B807DD21 /media/Storage ntfs-3g users 0 0 UUID=a60397fd-964a-45b1-ad35-53c8a4bee010 / ext4 defaults 0 1 UUID=1764825d-b8ba-4620-b3b0-e979b6f4f5c4 swap swap sw 0 0 UUID=255DA1E406E29DBC /media/sda2 ntfs-3g defaults 0 0 UUID=2CCCF161CCF1262C /mnt/sda1 ntfs-3g umask=000 0 0 /dev/fd0 /media/floppy0 vfat noauto 0 0 I started with an old XP install on disk /dev/sda that I don't use anymore but didn't want to delete, so I shrunk the XP partition, added a NTFS partition that would be common to both systems (Labeled it "Common" in XP), then installed Lucid on an extended ext4 partition. On this disk of course the ext4 system partition comes up as /, the go between partition auto-mounts on /media/sda1 but shows up in Nautilus as COMMOM, while the XP system disk does not show up in Nautilus, but I can get to it by navigating to /mnt/sda1. A second hard drive (/dev/sdb) that I stuck in was already formatted NTFS with a bunch of stuff and labeled "Storage". It auto-mounts to /media/Storage but another un-mounted disk also shows up in the Nautilus device area called Storage but it can't be mounted (Here and in the "Places" are the only times it appears) I would primarily like this non-existant (or already mounted depending on how you look at it) disk to not show up, but I wouldn't mind an explanation of why one labeled partition auto-mounts to a /media mount point but shows up by label, one does not show up as mounted at all but mounts to a /mnt mount point and is there for navigation, and one is mounted to a directory of the same name as the label. I would love to have some consistancy / direction on what is proper in this circumstance. No doubt I caused this with the fstab but I really don't remember what my rational was if I edited it manually

    Read the article

  • How do you forcibly unmount a disk when you press the eject button on an optical drive?

    - by Michael Curran
    When upgrading my hardware, I also upgraded to Ubuntu 10.10. On my previous system (with 10.04 and earlier) when I ejected a disk from the optical drive, the subfolder in the /media directory was automatically removed. In my new 10.10 system, if I don't eject the disk using the "eject" command within the system, the disk remains mounted, even after a new disk is installed. The new drive is a Blu Ray drive, but I haven't noticed any other problems from it. Normally, this isn't a problem, but it makes installing applications that are spread over multiple CDs more difficult in many cases (i.e. Wine). Any advice?

    Read the article

  • Can You Get Recovered Data From Wet Hard Drives?

    Most of us are aware of the fact that it is not recommended to have water and your hard drive connect with each other. The protective hard casing of your hard drive is not designed to withstand conta... [Author: Michiel Van Kets - Computers and Internet - May 08, 2010]

    Read the article

  • "A hard disk may be failing" , but no additional info via gdu-notification-deamon (suggestions?)

    - by blunders
    Got this message after logging in: A hard disk may be failing One or more hard disk report health problems. Click the icon to get more information. On WUBI and 10.04, there was no icon to click, and clicking on made the message go away. After rebooting, the message did not display again. I've got everything on all my hard drives in duplicate, so not super worried about a disk failure, though I am wondering why the message had no info on which disk it thought had problems. Suggestions?

    Read the article

  • Wubi install: How do I increase swap size

    - by Diogenes Lantern
    I am trying to increase the swapfile size on my WUBI install. I followed the answer here: sudo su swapoff -a cd /host/ubuntu/disks/ mv swap.disk swap.disk.bak dd if=/dev/zero of=swap.disk bs=1024 count=2097152 mkswap swap.disk swapon -a free -m until I reached: mv swap.disk swap.disk.bak At which point I have got got the following: root@ubuntu:/host/ubuntu/disks# mv swap.disk swap.disk.bak mv: cannot move `swap.disk' to `swap.disk.bak': Operation not permitted My 256 M swap space is all used up. I would like to install a total of twice that. Is there a method of setting it which would not include guesswork on my part?

    Read the article

  • How to make Ubuntu LiveCD be able to use USB Flash drive and external hard drive?

    - by ????
    I am booting up Ubuntu 2012.04 LiveCD... and was able to do /sudo mount /dev/sda1 /mnt and be able to see files in /mnt, which is the main hard drive that can't boot up any more. So to copy files from /mnt to an external hard drive or USB flash drive, I connected a 1TB external hard drive and 2 USB flash drives to the computer, but for some reason, in "File Systems", I can't drag and drop files from /mnt into those external hard drive or USB flash drives? I can't open or look into those drives either... How to make it work?

    Read the article

  • Meaning of the free space indication in Deluge

    - by Tjae Beamon
    Recently I installed Ubuntu 12.0.4 using Wubi with my current Windows Vista. I have already installed all the 265 updates from the Ubuntu software center and downloaded Deluge from there. My hardrive is 80GB according to the disc usage analyzer. It also says 31.2 GB used and 47.8GB free. The confusion comes when I run Deluge. At the bottom it says 2.0GB free space. Is that 2.0GB just a size set from the torrent client and can be changed or am I limited to just that 2.0GB?

    Read the article

  • Languages and VMs: Features that are hard to optimize and why

    - by mrjoltcola
    I'm doing a survey of features in preparation for a research project. Name a mainstream language or language feature that is hard to optimize, and why the feature is or isn't worth the price paid, or instead, just debunk my theories below with anecdotal evidence. Before anyone flags this as subjective, I am asking for specific examples of languages or features, and ideas for optimization of these features, or important features that I haven't considered. Also, any references to implementations that prove my theories right or wrong. Top on my list of hard to optimize features and my theories (some of my theories are untested and are based on thought experiments): 1) Runtime method overloading (aka multi-method dispatch or signature based dispatch). Is it hard to optimize when combined with features that allow runtime recompilation or method addition. Or is it just hard, anyway? Call site caching is a common optimization for many runtime systems, but multi-methods add additional complexity as well as making it less practical to inline methods. 2) Type morphing / variants (aka value based typing as opposed to variable based) Traditional optimizations simply cannot be applied when you don't know if the type of someting can change in a basic block. Combined with multi-methods, inlining must be done carefully if at all, and probably only for a given threshold of size of the callee. ie. it is easy to consider inlining simple property fetches (getters / setters) but inlining complex methods may result in code bloat. The other issue is I cannot just assign a variant to a register and JIT it to the native instructions because I have to carry around the type info, or every variable needs 2 registers instead of 1. On IA-32 this is inconvenient, even if improved with x64's extra registers. This is probably my favorite feature of dynamic languages, as it simplifies so many things from the programmer's perspective. 3) First class continuations - There are multiple ways to implement them, and I have done so in both of the most common approaches, one being stack copying and the other as implementing the runtime to use continuation passing style, cactus stacks, copy-on-write stack frames, and garbage collection. First class continuations have resource management issues, ie. we must save everything, in case the continuation is resumed, and I'm not aware if any languages support leaving a continuation with "intent" (ie. "I am not coming back here, so you may discard this copy of the world"). Having programmed in the threading model and the contination model, I know both can accomplish the same thing, but continuations' elegance imposes considerable complexity on the runtime and also may affect cache efficienty (locality of stack changes more with use of continuations and co-routines). The other issue is they just don't map to hardware. Optimizing continuations is optimizing for the less-common case, and as we know, the common case should be fast, and the less-common cases should be correct. 4) Pointer arithmetic and ability to mask pointers (storing in integers, etc.) Had to throw this in, but I could actually live without this quite easily. My feelings are that many of the high-level features, particularly in dynamic languages just don't map to hardware. Microprocessor implementations have billions of dollars of research behind the optimizations on the chip, yet the choice of language feature(s) may marginalize many of these features (features like caching, aliasing top of stack to register, instruction parallelism, return address buffers, loop buffers and branch prediction). Macro-applications of micro-features don't necessarily pan out like some developers like to think, and implementing many languages in a VM ends up mapping native ops into function calls (ie. the more dynamic a language is the more we must lookup/cache at runtime, nothing can be assumed, so our instruction mix is made up of a higher percentage of non-local branching than traditional, statically compiled code) and the only thing we can really JIT well is expression evaluation of non-dynamic types and operations on constant or immediate types. It is my gut feeling that bytecode virtual machines and JIT cores are perhaps not always justified for certain languages because of this. I welcome your answers.

    Read the article

  • Windows Server 2008 R2 network adapter stops working, requires hard reboot

    - by Geoff Dalgas
    TL;DR version: Turns out this was a Windows Server 2008 R2 kernel networking bug. After siccing Microsoft support on it, we (eventually) got an unpublished kernel hotfix from Microsoft to address it. If you, too, are experiencing mysterious low-level network driver failures requiring a reboot/bluescreen cycle, you might want that hotfix (or maybe Service Pack 1 whenever it is released, too.) We have been using HAProxy along with heartbeat from the Linux-HA project. We are using two linux instances to provide a failover. Each server has with their own public IP and a single IP which is shared between the two using a virtual interface (eth1:1) at IP: 69.59.196.211 The virtual interface (eth1:1) IP 69.59.196.211 is configured as the gateway for the windows servers behind them and we use ip_forwarding to route traffic. We are experiencing an occasional network outage on one of our windows servers behind our linux gateways. HAProxy will detect the server is offline which we can verify by remoting to the failed server and attempting to ping the gateway: Pinging 69.59.196.211 with 32 bytes of data: Reply from 69.59.196.220: Destination host unreachable. Running arp -a on this failed server shows that there is no entry for the gateway address (69.59.196.211): Interface: 69.59.196.220 --- 0xa Internet Address Physical Address Type 69.59.196.161 00-26-88-63-c7-80 dynamic 69.59.196.210 00-15-5d-0a-3e-0e dynamic 69.59.196.212 00-21-5e-4d-45-c9 dynamic 69.59.196.213 00-15-5d-00-b2-0d dynamic 69.59.196.215 00-21-5e-4d-61-1a dynamic 69.59.196.217 00-21-5e-4d-2c-e8 dynamic 69.59.196.219 00-21-5e-4d-38-e5 dynamic 69.59.196.221 00-15-5d-00-b2-0d dynamic 69.59.196.222 00-15-5d-0a-3e-09 dynamic 69.59.196.223 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 225.0.0.1 01-00-5e-00-00-01 static On our linux gateway instances arp -a shows: peak-colo-196-220.peak.org (69.59.196.220) at <incomplete> on eth1 stackoverflow.com (69.59.196.212) at 00:21:5e:4d:45:c9 [ether] on eth1 peak-colo-196-215.peak.org (69.59.196.215) at 00:21:5e:4d:61:1a [ether] on eth1 peak-colo-196-219.peak.org (69.59.196.219) at 00:21:5e:4d:38:e5 [ether] on eth1 peak-colo-196-222.peak.org (69.59.196.222) at 00:15:5d:0a:3e:09 [ether] on eth1 peak-colo-196-209.peak.org (69.59.196.209) at 00:26:88:63:c7:80 [ether] on eth1 peak-colo-196-217.peak.org (69.59.196.217) at 00:21:5e:4d:2c:e8 [ether] on eth1 Why would arp occasionally set the entry for this failed server as <incomplete>? Should we be defining our arp entries statically? I've always left arp alone since it works 99% of the time, but in this one instance it appears to be failing. Are there any additional troubleshooting steps we can take help resolve this issue? THINGS WE HAVE TRIED I added a static arp entry for testing on one of the linux gateways which still didn't help. root@haproxy2:~# arp -a peak-colo-196-215.peak.org (69.59.196.215) at 00:21:5e:4d:61:1a [ether] on eth1 peak-colo-196-221.peak.org (69.59.196.221) at 00:15:5d:00:b2:0d [ether] on eth1 stackoverflow.com (69.59.196.212) at 00:21:5e:4d:45:c9 [ether] on eth1 peak-colo-196-219.peak.org (69.59.196.219) at 00:21:5e:4d:38:e5 [ether] on eth1 peak-colo-196-209.peak.org (69.59.196.209) at 00:26:88:63:c7:80 [ether] on eth1 peak-colo-196-217.peak.org (69.59.196.217) at 00:21:5e:4d:2c:e8 [ether] on eth1 peak-colo-196-220.peak.org (69.59.196.220) at 00:21:5e:4d:30:8d [ether] PERM on eth1 root@haproxy2:~# arp -i eth1 -s 69.59.196.220 00:21:5e:4d:30:8d root@haproxy2:~# ping 69.59.196.220 PING 69.59.196.220 (69.59.196.220) 56(84) bytes of data. --- 69.59.196.220 ping statistics --- 7 packets transmitted, 0 received, 100% packet loss, time 6006ms Rebooting the windows web server solves this issue temporarily with no other changes to the network but our experience shows this issue will come back. Swapping network cards and switches I noticed the link light on the port of the switch for the failed windows server was running at 100Mb instead of 1Gb on the failed interface. I moved the cable to several other open ports and the link indicated 100Mb for each port that I tried. I also swapped the cable with the same result. I tried changing the properties of the network card in windows and the server locked up and required a hard reset after clicking apply. This windows server has two physical network interfaces so I have swapped the cables and network settings on the two interfaces to see if the problem follows the interface. If the public interface goes down again we will know that it is not an issue with the network card. (We also tried another switch we have on hand, no change) Changing network hardware driver versions We've had the same problem with the latest Broadcom driver, as well as the built-in driver that ships in Windows Server 2008 R2. Replacing network cables As a last ditch effort we remembered another change that occurred was the replacement of all of the patch cords between our servers / switch. We had purchased two sets, one green of lengths 1ft - 3ft for the private interfaces and another set of red cables for the public interfaces. We swapped out all of the public interface patch cables with a different brand and ran our servers without issue for a full week ... aaaaaand then the problem recurred. Disable checksum offload, remove TProxy We also tried disabling TCP/IP checksum offload in the driver, no change. We're now pulling out TProxy and moving to a more traditional x-forwarded-for network arrangement without any fancy IP address rewriting. We'll see if that helps. Switch Virtualization providers On the off chance this was related to Hyper-V in some way (we do host Linux VMs on it), we switched to VMWare Server. No change. Switch host model We've reached the end of our troubleshooting rope and are now formally involving Microsoft support. They recommended changing the host model: http://en.wikipedia.org/wiki/Host_model http://technet.microsoft.com/en-us/magazine/2007.09.cableguy.aspx We did that, and.. we'll see.

    Read the article

  • Benchmarking a file server

    - by Joel Coel
    I'm working on building a new file server... a simple Windows Server box with a few terabytes of disk space to share on the LAN. Pain for current hard drive prices aside :( -- I would like to get some benchmarks for this device under load compared to our old server. The old server was installed in 2005 and had 5 136GB 10K disks in RAID 5. The new server has 8 1TB disks in two RAID 10 volumes (plus a hot spare for each volume), but they're only 7.2K rpm, and of course with a much larger cache size. I'd like to get an idea of the performance expectations of the new server relative to the old. Where do I get started? I'd like to know both raw potential under different kinds of load for each server, as well an idea of what our real-world load looks like and how it will translate. Will disk load even matter, or will performance be more driven by the network connection? I could probably fumble through some disk i/o and wait counters in performance monitor, but I don't really know what to look for, which counters to watch, or for how long and when. FWIW, I'm expecting a nice improvement because of the benefits of having two different volumes and the better RAID 10 performance vs RAID 5, in spite of using slower disks... but I'd like to get an idea of how much.

    Read the article

  • What causes "A disk read error occurred, Press Ctrl + Alt + Del to restart"?

    - by Mehrdad
    I have a virtual machine containing Windows XP SP3. When I resized the VHD file (and the embedded partition), and tried booting, I got: A disk read error occurred Press Ctrl + Alt + Del to restart Some notes: FixBoot and FixMBR don't help. ChkDsk doesn't help. The partition is indeed active. The partition starts at sector 63 (it also did so before the problem) of cylinder 1, head 1, and is marked as type 0x07 (NTFS) My host OS reads the VHD and the partition completely fine I'm interested in knowing the cause rather than the fix. So "re-format the disk", "reinstall Windows", etc. aren't valid solutions. It's a virtual machine after all... I have nothing to lose, so I don't care about fixing it. I just want to know what's causing this problem, in case I run into it again on a physical machine (which I have done before). More info: The layout of the original, dynamic VHD (which works correctly): +-----------------------------------------------------------------------------+ ¦ Disk: 3 MBR/GPT: MBR ¦ ¦ Size: 127.00GB CHS: 16578 255 63 ¦ ¦ Sectors: 266338304 Disk Signature: 0xEE3EEE3E ¦ ¦ Partitions: 1 Partition Order: 1 ¦ ¦ Media Type: Fixed Interface: SCSI ¦ ¦ Description: Msft Virtual Disk ¦ +-----------------------------------------------------------------------------¦ ¦Pos Idx Type/Name Size Boot Hide Start Sector Total Sectors DL Vol Label ¦ +--- --- --------- ---- ---- ---- -------------- -------------- -- -----------¦ ¦ 1 1 07-NTFS 1.5G Yes No 63 3,148,677 F: <None> ¦ +-----------------------------------------------------------------------------+ The layout of the resized, fixed-size VHD (which doesn't work): +-----------------------------------------------------------------------------+ ¦ Disk: 3 MBR/GPT: MBR ¦ ¦ Size: 1.50GB CHS: 196 255 63 ¦ ¦ Sectors: 3149824 Disk Signature: 0xEE3EEE3E ¦ ¦ Partitions: 1 Partition Order: 1 ¦ ¦ Media Type: Fixed Interface: SCSI ¦ ¦ Description: Msft Virtual Disk ¦ +-----------------------------------------------------------------------------¦ ¦Pos Idx Type/Name Size Boot Hide Start Sector Total Sectors DL Vol Label ¦ +--- --- --------- ---- ---- ---- -------------- -------------- -- -----------¦ ¦ 1 1 07-NTFS 1.5G Yes No 63 3,148,677 F: <None> ¦ +-----------------------------------------------------------------------------+

    Read the article

< Previous Page | 90 91 92 93 94 95 96 97 98 99 100 101  | Next Page >