Search Results

Search found 57012 results on 2281 pages for 'com interop'.

Page 95/2281 | < Previous Page | 91 92 93 94 95 96 97 98 99 100 101 102  | Next Page >

  • How to send mail from ASP.NET with IIS6 SMTP in a dedicated server?

    - by Julio César
    Hi. I'm trying to configure a dedicated server that runs ASP.NET to send mail through the local IIS SMTP server but mail is getting stuck in the Queue folder and doesn't get delivered. I'm using this code in an .aspx page to test: <%@ Page Language="C#" AutoEventWireup="true" %> <% new System.Net.Mail.SmtpClient("localhost").Send("info@thedomain.com", "jcarrascal@gmail.com", "testing...", "Hello, world.com"); %> Then, I added the following to the Web.config file: <system.net> <mailSettings> <smtp> <network host="localhost"/> </smtp> </mailSettings> </system.net> In the IIS Manager I've changed the following in the properties of the "Default SMTP Virtual Server". General: [X] Enable Logging Access / Authentication: [X] Windows Integrated Authentication Access / Relay Restrictions: (o) Only the list below, Granted 127.0.0.1 Delivery / Advanced: Fully qualified domain name = thedomain.com Finally, I run the SMTPDiag.exe tool like this: C:\>smtpdiag.exe info@thedomain.com jcarrascal@gmail.com Searching for Exchange external DNS settings. Computer name is THEDOMAIN. Failed to connect to the domain controller. Error: 8007054b Checking SOA for gmail.com. Checking external DNS servers. Checking internal DNS servers. SOA serial number match: Passed. Checking local domain records. Checking MX records using TCP: thedomain.com. Checking MX records using UDP: thedomain.com. Both TCP and UDP queries succeeded. Local DNS test passed. Checking remote domain records. Checking MX records using TCP: gmail.com. Checking MX records using UDP: gmail.com. Both TCP and UDP queries succeeded. Remote DNS test passed. Checking MX servers listed for jcarrascal@gmail.com. Connecting to gmail-smtp-in.l.google.com [209.85.199.27] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to gmail-smtp-in.l.google.com. Connecting to gmail-smtp-in.l.google.com [209.85.199.114] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to gmail-smtp-in.l.google.com. Connecting to alt2.gmail-smtp-in.l.google.com [209.85.135.27] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to alt2.gmail-smtp-in.l.google.com. Connecting to alt2.gmail-smtp-in.l.google.com [209.85.135.114] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to alt2.gmail-smtp-in.l.google.com. Connecting to alt1.gmail-smtp-in.l.google.com [209.85.133.27] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to alt1.gmail-smtp-in.l.google.com. Connecting to alt2.gmail-smtp-in.l.google.com [74.125.79.27] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to alt2.gmail-smtp-in.l.google.com. Connecting to alt2.gmail-smtp-in.l.google.com [74.125.79.114] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to alt2.gmail-smtp-in.l.google.com. Connecting to alt1.gmail-smtp-in.l.google.com [209.85.133.114] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to alt1.gmail-smtp-in.l.google.com. Connecting to gsmtp183.google.com [64.233.183.27] on port 25. Connecting to the server failed. Error: 10060 Failed to submit mail to gsmtp183.google.com. Connecting to gsmtp147.google.com [209.85.147.27] on port 25. Connecting to the server failed. Error: 10051 Failed to submit mail to gsmtp147.google.com. I'm using ASP.NET 2.0, Windows 2003 Server and the IIS that comes with it. Can you tell me what else to change to fix the problem? Thanks @mattlant This is a dedicated server that's why I'm installing the SMTP manually. EDIT: I use exchange so its a little different, but its called a smart host in exchange, but in plain SMTP service config i think its called something else. Cant remember exactly the setting name. Thank you for pointing me at the Smart host field. Mail is getting delivered now. In the Default SMTP Virtual Server properties, the Delivery tab, click Advanced and fill the "Smart host" field with the address that your provider gives you. In my case (GoDaddy) it was k2smtpout.secureserver.net. More info here: http://help.godaddy.com/article/1283

    Read the article

  • How do read/interact with an old ActiveX SSUltraGrid using UIAutomation

    - by Nigel Thorne
    I am investigating automated testing of an old Win32 application that used ActiveX controls. I am spiking use White (from Thougthworks) that uses Microsoft UIAutomation. I can find the AutomationElement related to the control, but how do I interact with it? Spy++ sees the grid control as a single window, so I can't talk to rows, columns, or cells directly. How do I talk to the SSUltraGrid control from my test code? Cheers Nigel

    Read the article

  • Which version of MSXML should I use?

    - by Cheeso
    Seems like this would be a common question, though I could not find it on SO. Which version of MSXML should I use in my applications, and more importantly, how should I decide? There is MSXML3, 4, 5 and 6. I recently posted some code in calling-wcf-service-by-vbscript that used MSXML v4. AnthonyWJones posted that I shouldn't use 4, but instead 3 or 6, but probably 3. Certainly not v5! Why? I'd like to know more about the criteria for selecting the version of MSXML to use in my apps. Bonus question: Does anyone have a summary of the differences between the various versions of MSXML over time? Summary so far: MSXML6 Should be first choice. was released in 2006, and includes perf and compliance fixes. Use this if you can. It's good. There are no merge modules; to bundle the MSXML6 runtime with your app, MS suggests packaging the MSXML6 msi file. MSXML6 is an upgrade from MSXML3/4 but does not replace them, because it discontinues some features. You can get the MSI here. MSXML3 Second choice. Most widely deployed version. Originally shipped in March 2000. Actively maintained, no new features. Currently supported, if you are on SP5 (shipped in 2005) or later. SP7 is current (also from 2005). MSXML5 was released only as part of MS-Office. Currently supported by Microsoft, but only as part of Office, not for building apps. Don't build apps that depend on MSXML5: Verboten. MSXML4 originally shipped? Currently in "maintenance mode". Microsoft is encouraging people to move off MSXML4 to MSXML6. Currently supported if you are on MSXML4SP2 or later, which shipped in 2003. download MSXML4SP2 here. Can be redisributed. Using the right version of MSXML in Internet Explorer is a good entry on the blog from Microsoft's xmlteam.

    Read the article

  • python win32com EXCEL data input error

    - by Rafal
    Welcome, I'm exporting results of my script into Excel spreadsheet. Everything works fine, I put big sets of data into SpreadSheet, but sometimes an error occurs: File "C:\Python26\lib\site-packages\win32com\client\dynamic.py", line 550, in __setattr__ self._oleobj_.Invoke(entry.dispid, 0, invoke_type, 0, value) pywintypes.com_error: (-2147352567, 'Exception.', (0, None, None, None, 0, -2146777998), None)*** I suppose It's not a problem of input data format. I put several different types of data strings, ints, floats, lists and it works fine. When I run the sript for the second time it works fine - no error. What's going on? PS. This is code that generates error, what's strange is that the error doesn't occur always. Say 30% of runs results in an error. : import win32com.client def Generate_Excel_Report(): Excel=win32com.client.Dispatch("Excel.Application") Excel.Workbooks.Add(1) Cells=Excel.ActiveWorkBook.ActiveSheet.Cells for i in range(100): Row=int(35+i) for j in range(10): Cells(int(Row),int(5+j)).Value="string" for i in range(100): Row=int(135+i) for j in range(10): Cells(int(Row),int(5+j)).Value=32.32 #float Generate_Excel_Report() The strangest for me is that when I run the script with the same code, the same input many times, then sometimes an error occurs, sometimes not. Thanks in advance for any help

    Read the article

  • Troubleshooting a COM+ application deadlock

    - by Chris Karcher
    I'm trying to troubleshoot a COM+ application that deadlocks intermittently. The last time it locked up, I was able to take a usermode dump of the dllhost process and analyze it using WinDbg. After inspecting all the threads and locks, it all boils down to a critical section owned by this thread: ChildEBP RetAddr Args to Child 0deefd00 7c822114 77e6bb08 000004d4 00000000 ntdll!KiFastSystemCallRet 0deefd04 77e6bb08 000004d4 00000000 0deefd48 ntdll!ZwWaitForSingleObject+0xc 0deefd74 77e6ba72 000004d4 00002710 00000000 kernel32!WaitForSingleObjectEx+0xac 0deefd88 75bb22b9 000004d4 00002710 00000000 kernel32!WaitForSingleObject+0x12 0deeffb8 77e660b9 000a5cc0 00000000 00000000 comsvcs!PingThread+0xf6 0deeffec 00000000 75bb21f1 000a5cc0 00000000 kernel32!BaseThreadStart+0x34 The object it's waiting on is an event: 0:016> !handle 4d4 f Handle 000004d4 Type Event Attributes 0 GrantedAccess 0x1f0003: Delete,ReadControl,WriteDac,WriteOwner,Synch QueryState,ModifyState HandleCount 2 PointerCount 4 Name <none> No object specific information available As far as I can tell, the event never gets signaled, causing the thread to hang and hold up several other threads in the process. Does anyone have any suggestions for next steps in figuring out what's going on? Now, seeing as the method is called PingThread, is it possible that it's trying to ping another thread in the process that's already deadlocked? UPDATE This actually turned out to be a bug in the Oracle 10.2.0.1 client. Although, I'm still interested in ideas on how I could have figured this out without finding the bug in Oracle's bug database.

    Read the article

  • How do I create interface methods using .tlb types in VS C++?

    - by Steven
    Background: The .TLB file contains interfaces written in language 'X'. I don't have .h, .idl, .tlh, or any other header files - just the .TLB file. Language 'X' does not export compatible .h, .idl, etc. I use the VS wizard to add an ATL simple object to my ATL project. I want to add a method to the interface of my simple ATL object that uses one of the .TLB defined types for a parameter. // Something like the following in the .idl file: interface ISomeInterface : IUnknown { HRESULT SomeMethod([in] ITypeFromTLB* aVal); // ITypeFromTLB declared in .TLB file. }; How can I do this? I'm hoping for a wizard, or a line in the .idl interface declaration that would bring in the .tlb information. midl's include (no .tlb), import (no tlb), and importlib (library only) don't seem to provide a solution (I need proxy/stub to be working, so I cannot put this inside the library declaration with the importlib command). Thanks.

    Read the article

  • STAThread and Process output capture in c#

    - by alex
    Hi: This is a strange problem I encountered. I have an window application written in c# to do testing. It has a MDI parent form that is hosting a few children forms. One of the forms launch test cripts by creating processes and capture the scripts output to a text box. Another form open serial port and monitoring the status of the device I am working on(like a shell). If I ran both of them together, the output of the script seems only appear in the text box after the test is done. However, If I don't open the serial port form, the output of the script is captured in real time. Does anyone knows what's causing the problem? I notice the onDataReceived even handler for serial port form has a [STAThread] header to it. Will this cause the serial port thread having higher priority than other processes? Thanks in advance.

    Read the article

  • How to invoke client ActiveX via javascript

    - by Captain Kidd
    Hi I want to let server to invoke client ActiveX via javascript. The script work well as it run on my local system. Then I place it into Apache Server and it's malfunction. Script: <object id="lv_obj" classid = "CLSID:30A92485-94D2-4CBA-AC32-EF276B7F777B" CODEBASE="" ></OBJECT> try { document.all.lv_obj.Init("PCS_Tes"); } catch (err) { window.alert("????: " + err.message); } I guess the reason is script on server can't invoke user client ActiveX. If I need config something on Apache?

    Read the article

  • How do I render the scrollable regions of a canvas with IViewObject::Draw?

    - by nirvdrum
    Hi, I've been trying to render the entire canvas in an IWebBrowser2 control to a bitmap. IViewObject::Draw seems to be the most promising approach, but I can't get it to render anything that would requires a scroll to show. While I could automate the scrolling and stitch the images together, this would look weird with any fixed position elements. Is this even doable? Additionally, I've tried to set the controller's size to one that would allow the entire contents to display without needing to scroll, but Windows caps the max size to the current screen resolution, so that only gets me partially there. Any help would be much appreciated. I'm currently doing this in the context of Win7 and IE8, but I don't think that should matter much.

    Read the article

  • Abstract Methods in "Product" - Factory Method C#

    - by Regina Foo
    I have a simple class library (COM+ service) written in C# to consume 5 web services: Add, Minus, Divide, Multiply and Compare. I've created the abstract product and abstract factory classes. The abstract product named WS's code: public abstract class WS { public abstract double Calculate(double a, double b); public abstract string Compare(double a, double b); } As you see, when one of the subclasses inherits WS, both methods must be overridden which might not be useful in some subclasses. E.g. Compare doesn't need Calculate() method. To instantiate a new CompareWS object, the client class will call the CreateWS() method which returns a WS object type. public class CompareWSFactory : WSFactory { public override WS CreateWS() { return new CompareWS(); } } But if Compare() is not defined as abstract in WS, the Compare() method cannot be invoked. This is only an example with two methods, but what if there are more methods? Is it stupid to define all the methods as abstract in the WS class? My question is: I want to define abstract methods that are common to all subclasses of WS whereas when the factory creates a WS object type, all the methods of the subclasses can be invoked (overridden methods of WS and also the methods in subclasses). How should I do this?

    Read the article

  • Hooking the http/https protocol in IE causes GET requests to be sequential

    - by watsonmw
    I'm using the PassthruAPP method to hook into HTTP/HTTPS requests made by IE. It's working well for the most part, however I noticed a problem. Only one download thread is active at a time. I can see two IInternetProtocol objects getting created, but IE uses only one at a time. This is happening with IE7. The odd thing is that the problem occurs when overriding the existing default HTTP/HTTPS handler, even if the handler is not the one being used to make the request. E.g. Registering a handler for the HTTPS protocol will cause HTTP requests to be made sequentially, even though HTTP requests are not hooked. I installed Google Gears and it has the same problem. This always happens for the first few items on the page, but it seems that after the document complete is issued, concurrent downloads can occur again. For example Javascript code that is executed after the page has finished loading can load images concurrently just fine. One option is to try to IAT patch the 'IInternetProtocol' registered for HTTP requests, but Google Gears does this already and it has the same problem. I know installing a HTTP Proxy is another option, but I don't want to monkey with the users' HTTP Proxy settings if there another option.

    Read the article

  • Moving delegate-related function to a different thread

    - by Chris
    Hello everybody. We are developing a library in C# that communicates with the serial port. We have a function that is given to a delegate. The problem is that we want it to be run in a different thread. We tried creating a new thread (called DatafromBot) but keep using it as follows (first line): comPort.DataReceived += new SerialDataReceivedEventHandler(comPort_DataReceived); DatafromBot = new Thread(comPort_DataReceived); DatafromBot.Start(); comPort_DataReceived is defined as: Thread DatafromBot; public void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { ... } The following errors occur: Error 3 The best overloaded method match for 'System.Threading.Thread.Thread(System.Threading.ThreadStart)' has some invalid arguments C:...\IR52cLow\CommunicationManager.cs 180 27 IR52cLow Error 4 Argument '1': cannot convert from 'method group' to 'System.Threading.ThreadStart' C:...\IR52cLow\CommunicationManager.cs 180 38 IR52cLow Any ideas of how we should convert this to get it to compile? Please note that comPort.DataReceived (pay attention to "." instead of "_") lies within a system library and cannot be modified. Thanks for your time! Chris

    Read the article

  • Internet Explorer cannot 'fully' load ActiveX Control

    - by K Browne
    Context I am migrating an installer for an ActiveX control from Per-Machine to Per-User. I did this by programming the installer write to HKCU\Software\Classes instead of HKLM\Software\Classes. Problem On my machine (Windows 7 with UAC Enabled), the ActiveX control successfully loads. On the other windows 7 test machines (one with UAC enabled, one with UAC disabled), the control 'partially' loads. What is Partially? When a user visits a page with the ActiveX control, Internet Explorer displays a warning message in a yellow bar on the top of the window. If you click the 'Run add-on' button in the bar, the control becomes visible and begins to run, but Javascript code that tries to access properties of the control return the error: Library not registered. Differences between machines On the dev machine reads from HKCR\CLSID\<GUID> succeed while on the test machines these reads fail. Reads from HKCU succeed on both dev and test machines. Reads from HKLM fail on both test and dev machines. (I collected reads using Sysinternals Process Monitor) Strangely, the keys that Internet Explorer fails to read are clearly visible if I use regedit to view HKCR\CLSID\<GUID> on the test machines. Question What can I do to get the per-user control to load on the test machines? What could cause this difference between the dev machine and the test machines? Why can I see the key in HKCR with RegEdit but Internet Explorer cannot see the key? Any help is appreciated. Thank you.

    Read the article

  • Trying to populate ListView in Android using objects from Parse

    - by mrwienerdog
    I am pretty darned new to android, and VERY new to Parse. I have created a class, StudentInformation, that includes columns for name, address, phone, etc. I would like to create a listview that contains the names of all students added to the class. How do I do this? I have got it to the point that I can Toast out the objectIDs of all of my entries, but can't figure out how to extract and add just the names to the ListView. Here is a snippet of the code: //Set up the listview studentListView = (ListView)findViewById(R.id.listViewStudents); //Create and populate an ArrayList of objects from parse ParseQuery query = new ParseQuery("StudentInformation"); final ArrayList<Object> studentList = new ArrayList<Object>(); query.findInBackground(new FindCallback() { public void done(List<ParseObject> objects, ParseException e) { if (e == null) { Toast.makeText(getApplicationContext(), objects.toString(), Toast.LENGTH_LONG).show(); for(int i = 0;i < objects.size(); i++){ objects.get(i); studentList.add("name".toString()); } } else { Toast.makeText(getApplicationContext(), "Error", Toast.LENGTH_LONG).show(); } } }); //studentList.addAll(Arrays.asList(students)); listAdapter = new ArrayAdapter<Object>(this,android.R.layout.simple_list_item_1,studentList); studentListView.setAdapter(listAdapter); } I have left the toast in where I toatst out the objectIDs in the public void done.... method. Any help would be, as always, greatly appreciated. Should be mentioned (possibly), no errors are thrown, the listview just never gets populated after the toast disappears. Don't know if this will help anyone, but I took a bit from both posts below, and came up with this: //Set up the listview studentList = new ArrayList<String>(); //Create and populate an ArrayList of objects from parse listAdapter = new ArrayAdapter<String>(this,android.R.layout.simple_list_item_1); studentListView = (ListView)findViewById(R.id.listViewStudents); studentListView.setAdapter(listAdapter); final ParseQuery query = new ParseQuery("StudentInformation"); query.findInBackground(new FindCallback() { public void done(List<ParseObject> objects, ParseException e) { if (e == null) { //Toast.makeText(getApplicationContext(), objects.toString(), Toast.LENGTH_LONG).show(); for (int i = 0; i < objects.size(); i++) { Object object = objects.get(i); String name = ((ParseObject) object).getString("name").toString(); listAdapter.add(name); } } else { Toast.makeText(getApplicationContext(), "Error", Toast.LENGTH_LONG).show(); } } });

    Read the article

  • Should a Stack have a maximum size?

    - by Sotirios Delimanolis
    I'm practicing my knowledge of ADTs by implementing some data structures, even if most already exist. With Stacks, a lot of books and other documentation I've read talk about the stack throwing an error when you try to add an element but the stack is full. In a java implementation (or any other), should I specifically keep track of a maximum stack size (from constructor), check to see if that size is reached, and throw an overflow exception if it is? Or is not such a big deal?

    Read the article

  • How can I access the JavaScript global object ("window") inside an embedded browser object (the IWebBrowser2 interface)?

    - by John Factorial
    I have an HTML page which embeds an IWebBrowser2 ActiveX (i.e. the control is essentially an Internet Explorer browser). I need to write JavaScript in this HTML page which will remove any window.onresize handler from the page loaded in the IWebBrowser2 control. IWebBrowser2 exposes the DOM through IWebBrowser2::Document, but this is equivalent to window.document. Is there any way I can get access to window or window.onresize?

    Read the article

  • Problem catching OnClick event using HTMLDocumentEvents2 in a BHO

    - by Yonatan
    I am running a BHO and i am trying to catch OnClick events using HTMLDocumentEvents2 however, the events never seem to reach the handler this is what i am doing: class ATL_NO_VTABLE CBlastBhoBHO : public CComObjectRootEx<CComSingleThreadModel>, public CComCoClass<CBlastBhoBHO, &CLSID_BlastBhoBHO>, public IObjectWithSiteImpl<CBlastBhoBHO>, public IDispatchImpl<IBlastBhoBHO, &IID_IBlastBhoBHO, &LIBID_BlastBhoLib, /*wMajor =*/ 1, /*wMinor =*/ 0>, public IDispEventImpl<0, CBlastBhoBHO, &DIID_HTMLDocumentEvents2, &LIBID_MSHTML, 1, 0>, public IDispEventImpl<1, CBlastBhoBHO, &DIID_DWebBrowserEvents2, &LIBID_SHDocVw, 1, 1> BEGIN_SINK_MAP(CBlastBhoBHO) SINK_ENTRY_EX(0, DIID_HTMLDocumentEvents2, DISPID_HTMLDOCUMENTEVENTS2_ONCLICK, OnClickTrigger) SINK_ENTRY_EX(1, DIID_DWebBrowserEvents2, DISPID_DOCUMENTCOMPLETE, OnDocumentComplete) END_SINK_MAP() // Handlers void STDMETHODCALLTYPE CBlastBhoBHO::OnDocumentComplete( IDispatch *pDisp, VARIANT *url) { // works fine } void STDMETHODCALLTYPE CBlastBhoBHO::OnClickTrigger(IHTMLEventObj *pEvtObj) { // Never called } // From SetSite() ATL::IDispEventSimpleImpl<1,CBlastBhoBHO,&DIID_DWebBrowserEvents2>::DispEventAdvise(m_spWebBrowser); // From OnDocumentComplete CComQIPtr<IHTMLDocument3> doc_; m_spWebBrowser->get_Document((IDispatch**) &doc_); ATL::IDispEventSimpleImpl<0,CBlastBhoBHO,&DIID_HTMLDocumentEvents2>::DispEventAdvise(doc_); I have tried several variations(using HTMLElementEvents2 etc) or Advising on different objects or Advising on the document from SetSite. my handler is never called. Any help would be much appreciated. all i need is the onClick event.

    Read the article

  • Sending binary data from ASP to .net component

    - by john
    The ASP application allows uploading of image files (jpg, gif, tif). These files are sent to a .net component registered in the GAC of the server. In the component file is encoded using System.Text.Unicode to byte[] array. This encoding is done with some data loss. The byte array has values 253 and 255 in consequetive elements. What could be the problem ? I'm sending the binary data as a string. Please help me... Thanks in advance, John

    Read the article

  • .NET: How does the use of components in .NET differ to pre-.NET?

    - by Craig Johnston
    How does the use of components in .NET differ to pre-.NET? I see the differences as: .NET components don't have to be centrally registered on a machine and can merely be invoked at run-time from a specified location if .NET components are 'registered' in the GAC, problems asociated with different versions of the same DLL ("DLL hell") are avoided because each version will have its own id/key which is known to the calling program Is the above correct, and what other relevant differences are there?

    Read the article

  • import data from the objects created in salesforce

    - by javatechi
    Hi All, I have created an app in salesforce platform, i have some primitive records in that, i need to import them in visual force. For example,if we create a record in Account in Salesforce,,, like charles,Jennifer,Tom and all i need to import them in visualforce and do things which i can do in salesforce..please help me out with this Thanks

    Read the article

  • Retrieving dll version info via Win32 - VerQueryValue(...) crashes under Win7 x64

    - by user256890
    The respected open source .NET wrapper implementation (SharpBITS) of Windows BITS services fails identifying the underlying BITS version under Win7 x64. Here is the source code that fails. NativeMethods are native Win32 calls wrapped by .NET methods and decorated via DllImport attribute. private static BitsVersion GetBitsVersion() { try { string fileName = Path.Combine( System.Environment.SystemDirectory, "qmgr.dll"); int handle = 0; int size = NativeMethods.GetFileVersionInfoSize(fileName, out handle); if (size == 0) return BitsVersion.Bits0_0; byte[] buffer = new byte[size]; if (!NativeMethods.GetFileVersionInfo(fileName, handle, size, buffer)) { return BitsVersion.Bits0_0; } IntPtr subBlock = IntPtr.Zero; uint len = 0; if (!NativeMethods.VerQueryValue(buffer, @"\VarFileInfo\Translation", out subBlock, out len)) { return BitsVersion.Bits0_0; } int block1 = Marshal.ReadInt16(subBlock); int block2 = Marshal.ReadInt16((IntPtr)((int)subBlock + 2 )); string spv = string.Format( @"\StringFileInfo\{0:X4}{1:X4}\ProductVersion", block1, block2); string versionInfo; if (!NativeMethods.VerQueryValue(buffer, spv, out versionInfo, out len)) { return BitsVersion.Bits0_0; } ... The implementation follows the MSDN instructions by the letter. Still during the second VerQueryValue(...) call, the application crashes and kills the debug session without hesitation. Just a little more debug info right before the crash: spv = "\StringFileInfo\040904B0\ProductVersion" buffer = byte[1900] - full with binary data block1 = 1033 block2 = 1200 I looked at the targeted "C:\Windows\System32\qmgr.dll" file (The implementation of BITS) via Windows. It says that the Product Version is 7.5.7600.16385. Instead of crashing, this value should return in the verionInfo string. Any advice?

    Read the article

< Previous Page | 91 92 93 94 95 96 97 98 99 100 101 102  | Next Page >