  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • What is this Cable for? 4 Pin to 2 Pin from Riser to Perc in Dell R410

    - by Kyle Brandt
    I got a new raid card for a R410 server since the S300 that came with it doesn't support raid with Linux (No work around for this if SAS from what I could find). Anyways, the RAID card has 2 pins on it and there is a cable that that connects to a 4 pin connection on the riser. The cable only has two wires, one black and one red. What is this cable for? My guess would be maybe LED status for the front panel or something like that, but I am just guessing....

    Read the article

  • SATA drive not recognized when installing RHEL 5.1 on PowerEdge R410

    - by Rachel
    Here's my setup: Dell R410 with Perc S100 (software) raid controller on an Intel ICH10R chipset The first problem is that the Perc S100 is only supported on windows. I'm trying to install RHEL 5.1. It boots from the cdrom, but later the installer can't see the cdrom or hard drive. Both are connected to the on-board sata controller. The only options in the R410 bios for SATA are ATA or RAID. I don't need raid, I just want a single drive setup.

    Read the article

  • Dell PowerEdge R410: System asks to press F1 or F2

    - by hurikhan77
    We just installed an option card (PERC 6/i) into a brand-new Dell PowerEdge R410 and now the system does no unattended startup but instead asks me to press F1 to continue or F2 to enter system setup after printing the following message on the console: Fan 4 speed may change depending on system configuration and option card install. How do I make the system ignore this "problem" or whatever that is? This system is going to be installed at a remote data center and needs to be able to restart unattended. I do not want to ignore errors completely to not get endless restart loops in case of errors.

    Read the article

  • Intsalling Linux on PowerEdge R410 via USB

    - by Bill Johnson
    I’m hoping someone can help me with the following issue. I have a Dell PowerEdge R410 and basically the Optical Drive has failed when I have been given the server. I have installed 2 SATA drives and want to install Ubuntu 11.04; however, each time I have tried i.e. using bootable .iso on USB it failed. I assume it's failing as with a lot of releases they all look at the CD drive. Ubunutu has failed on installation with the error message unable to mount CD. I have tried installing Microsoft Hyper-v and that also fails as during installation it asks for CD/DVD drivers. Tried embedding ISO's from various distro's (Linux and Windows) with drivers and that hasn't worked out either. Does anyone have any idea on how I can get Ubuntu on this server? Should I look towards an old distro perhaps?

    Read the article

  • Migrating 2008 AD to Windows SBS 2011 and Forefront TMG 2010

    - by Tong Wang
    Our company has two physical servers: a Dell R710 with 4 NIC and a Dell R410 with 2 NIC. Right now, we have Windows server 2008 R2 installed on R710 with AD setup to host our domain. I am thinking to install both SBS 2011 and TMG 2010 on the other R410 running on Hyper-V. As I am fairly new to Windows Server technology, I'd like to check with you fellow Windows admins and see what is the proper way to install SBS 2011 and TMG 2010 and how to migrate the 2008 AD. Your advice and help will be highly appreciated.

    Read the article

  • How to fix Windows 2008 R2 show less memory than available

    - by eugeneK
    I've got Win2008 R2 64bit installed on Dell R410 server with 8GB of RAM. Dell Open Manage shows 8GB total and 4GB available for use, In Windows Control Panel, System i see 64bit and 8GB of RAM while in Windows Task Manager at Performance tab there is 4GB of memory available. Dell support has made some checks and told me that if BIOS shows 8Gb of RAM and indeed BIOS does then it's operational system issue. Tried to search online for resolution but none found. Please help, thanks

    Read the article

  • Restrict IPMI access on Dell BMC and iDRAC to an allowed IP range

    - by edgester
    I'm trying to secure the iDRAC's and BMC's on some of my Dell servers (R210, R410, R510). I want to restrict access to IPMI commands to only a few IP addresses. I've successfully restricted access to the iDrac using the instructions from http://support.dell.com/support/edocs/software/smdrac3/idrac/idrac10mono/en/ug/html/racugc2d.htm#wp1181529 , but the IP restrictions do not affect IPMI. A separate management network is not practical at this time because of lack or ports and some Dell BMC's don't offer a separate port. I'm told by my networking group that our switches don't support trunking, so using the vlan tagging is not an option either. Is there a way restrict the IPMI access to a list of allowed addresses? FYI, for various reasons, I have a mix of Dell servers with BMC's, iDrac Express and iDrac enterprise management features.

    Read the article

  • Windows-Server-2003 setup on Dell-PowerEdge R310 is hanging [closed]

    - by Robert Rose
    Possible Duplicate: Problems installing OS on Dell PowerEdge R410 I am trying to configure a Dell PowerEdge R310 server with Windows Server 2003. I've already configured the two hard drives as RAID1. The HD controller is PERC H700 Integrated and Adapter. Trying to stay with Windows Server 2003 on this fairly new server to save on cost and keep the configuration the same as my old server, which has been running like a champ for five years. Problem: During the OS installation, after everything has been copied from the installation CD, the installation hangs at a window labeled 'Windows Setup' with the message 'Setup is starting Windows' at the bottom. I'm wondering if this is a driver problem and if so, where can I get the drivers for the R310 or where can I get the media for the latest version of Windows Server 2003 which may include the necessary drivers? Will certainly appreciate some help here.

    Read the article

  • Setting up a Windows Server 2008 R2 DC + Fileserver : native or virtual?

    - by user126890
    I want to deploy a new DC + Fileserver using Windows Server 2008 R2 SP1 Standard Edition on a Dell PowerEdge R410 and iSCSI storage for a small business (~30 people). Should I install the system native on the server or use a virt layer? I don't have a budget for virtualization so i gotta go with something free... What's a better working routine, taking snapshots of vm's or taking backups (Acronis/CloneZilla) of systems? If I use a virt system, I need a GUI for some people in the business to reset the system to a earlier state in emergency situations. I wanted to install phpVirtualBox once but never finished, is it suitable in a productive environment? server specs: Intel Xeon E5620 CPU (2,40GHz, 4C, 12MB Cache) 8GB RAM Dual Rank LV RDIMMs 1333MHz 2x 1TB SATA 7,2K 3,5, RAID1

    Read the article

  • Centos and dell PowerEdge Rxxx Series.

    - by OrenM
    hi we lately purchase few dell servers all of them from Rxxx series couple of R410 and R710 the OS we used on those servers is: CentOS 5.4 we're getting very weird error messages and we lost network connectivity couple of times (restarting the network interface was needed to fix it) the messages we're getting are: Message from syslogd@ at Wed Nov 18 12:07:08 2009 ... servername kernel: Uhhuh. NMI received for unknown reason 20. Message from syslogd@ at Wed Nov 18 12:07:08 2009 ... servername kernel: Do you have a strange power saving mode enabled? Message from syslogd@ at Wed Nov 18 12:07:08 2009 ... servername kernel: Dazed and confused, but trying to continue we have never seen those messages in the previous series of dell poweredge servers do someone here using centOS 5.4 on Rxxx series? did it happen to him too? maybe you have a suggestion about how to prevent it from happening

    Read the article

  • Windows 2008 R2 server cannot access shares on other servers

    - by Rob
    I have a problem on my new 2008 R2 64-bit server. Essentially the server sometimes refuses to access shares on other server. in the format \\servernam\sharename sometime it works and then for a few hours it doesn't and then at randon it comes back online. This is a local AD network and have even put in a new gigabit switch between all server. All the old 2003 servers work fine so I know DNS and WINS is all ok. I get error 1006 in eventlog saying that my R2 server can't contact the domain controller when it clearly can. Just to add to the config, it is running on a Dell PowerEdge R410, Vmware Esxi 4.0 and R2 is configured as a terminal server. I can always view shares with FQDN This morning net view \\ did not work but net view \\ did. Very random and very frustrating. any ideas? thanks

    Read the article

  • ESXi Server with 12 physical cores maxed out with only 8 cores assigned in virtual machines

    - by Sam
    I have an ESXi 5 server running on a 2-processor, 12-core system with hyperthreading enabled. So: 12 physical cores, 24 logical ones. On this server are 4 Windows 7 VMs, each configured for 2 processors, each running VMware Tools. Looking at my stats in vSphere, my "core utilization" is constantly maxed out. Yes, these machines are working hard, but only 8 cores have been allocated. How is this possible? Should I look into reducing the processor count per machine as in this post: VMware ESX server? I checked to ensure that hardware virtualization is enabled in the BIOS of the machine (a DELL R410). I've also started reading up on configuration, but being a newbie there's a lot of material to catch up on. It also seems I should only bother with advanced settings and pools if I'm really pushing the load, and I don't think that I should be pushing it with so few VMs. I suspect that I have some basic, incorrect configuration setting, but it's also possible that I have some giant misconceptions about virtualization. Any pointers? EDIT: Given the responses I've gotten so far, it seems that this is a measurement problem and not a configuration problem, making this less critical. Perhaps the real question is: How does the core utilization of the server reach a higher percentage than all individual cores' core utilization, and given that this possibility makes the metric useless for overall server load, what is the best global metric for measuring CPU load on hyper-threaded systems?

    Read the article

  • Server Performance

    - by sb12
    I know very little about performance tuning of servers etc... so i thought i'd put this up here as i start some research on it, just to get some direction. I am in the process of migrating from my old server to a new one - both are 64 bit machines. One is a few years old, the other brand new (PowerEdge R410). The old server spec is: 2 cpus, 3.4GHz Pentiums, 8G of RAM, Fedora 11 currently installed The new server spec is: 16 cpus, 3.2 GHz Xeon, 16G of RAM, CentOS 6.2 installed. Also RAID10 is on the new server - no RAID on the old one. Both servers currently have the same database (MySQL) with the same data migrated. I wrote a Perl script that simply steps through each row of a table in the database (about 18000 rows) and updates a value in that row. Every row in the table is updated. Out of curiosity i ran this perl script on both machines, just to see how the new server would perform vs. the old one, and it produced interesting results: The old server was twice as fast as the new one to complete. Looking at the database, both are configured exactly the same (the new one being a dump of the old one...)... Anyone any ideas why this would be given the hardware gap between both? As i said i'm about to start some digging, but thought i'd put this up here to maybe get some good direction.... Many thanks in advance..

    Read the article

  • How do I find the cause for a huge difference in performance between two identical Ubuntu servers?

    - by the.duckman
    I am running two Dell R410 servers in the same rack of a data center. Both have the same hardware configuration, run Ubuntu 10.4, have the same packages installed and run the same Java web servers. No other load. One of them is 20-30% faster than the other, very consistently. I used dstat to figure out, if there are more context switches, IO, swapping or anything, but I see no reason for the difference. With the same workload, (no swapping, virtually no IO), the cpu usage and load is higher on one server. So the difference appears to be mainly CPU bound, but while a simple cpu benchmark using sysbench (with all other load turned off) did yield a difference, it was only 6%. So maybe it is not only CPU but also memory performance. I tried to figure out if the BIOS settings differ in some parameter, did a dump using dmidecode, but that yielded no difference. I compared /proc/cpuinfo, no difference. I compared the output of cpufreq-info, no difference. I am lost. What can I do, to figure out, what is going on?

    Read the article

  • compile lastest bnx2 driver on debian squeeze

    - by markus
    I want to upgrade the bnx2 network card driver in a Dell Power Edge R410. I downloaded the latest driver version from the broadcom website. If I want to compile the driver it fails with the following errors: make make -C bnx2/src KVER=2.6.32-5-amd64 PREFIX= make[1]: Entering directory `/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src' make -C /lib/modules/2.6.32-5-amd64/build SUBDIRS=/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src modules make[2]: Entering directory `/usr/src/linux-headers-2.6.32-5-amd64' Building modules, stage 2. MODPOST 2 modules make[2]: Leaving directory `/usr/src/linux-headers-2.6.32-5-amd64' make[1]: Leaving directory `/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src' make -C bnx2x/src KVER=2.6.32-5-amd64 PREFIX= make[1]: Entering directory `/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src' make -C /lib/modules/2.6.32-5-amd64/build M=`pwd` modules make[2]: Entering directory `/usr/src/linux-headers-2.6.32-5-amd64' CC [M] /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.o In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1009:1: error: "PCI_VPD_LRDT_ID_STRING" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1327:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1011:1: error: "PCI_VPD_LRDT_RO_DATA" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1328:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1013:1: error: "PCI_VPD_LRDT_RW_DATA" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1329:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1019:1: error: "PCI_VPD_SRDT_END" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1334:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1032: error: conflicting types for ‘pci_vpd_lrdt_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1355: error: previous definition of ‘pci_vpd_lrdt_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1037: error: conflicting types for ‘pci_vpd_srdt_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1366: error: previous definition of ‘pci_vpd_srdt_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1042: error: conflicting types for ‘pci_vpd_find_tag’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1391: error: previous declaration of ‘pci_vpd_find_tag’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1077: error: conflicting types for ‘pci_vpd_info_field_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1377: error: previous definition of ‘pci_vpd_info_field_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1082: error: conflicting types for ‘pci_vpd_find_info_keyword’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1403: error: previous declaration of ‘pci_vpd_find_info_keyword’ was here make[5]: *** [/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.o] Fehler 1 make[4]: *** [_module_/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src] Fehler 2 make[3]: *** [sub-make] Fehler 2 make[2]: *** [all] Fehler 2 make[2]: Leaving directory `/usr/src/linux-headers-2.6.32-5-amd64' make[1]: *** [bnx2x.o] Fehler 2 make[1]: Leaving directory `/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src' make: *** [l2build] Fehler 2

    Read the article

  • RAID1 rebuild fails due to disk errors

    - by overlord_tm
    Quick info: Dell R410 with 2x500GB drives in RAID1 on H700 Adapter Recently one of drives in RAID1 array on server failed, lets call it Drive 0. RAID controller marked it as fault and put it offline. I replaced faulty disk with new one (same series and manufacturer, just bigger) and configured new disk as hot spare. Rebuild from Drive1 started immediately and after 1.5 hour I got message that Drive 1 failed. Server was unresponsive (kernel panic) and required reboot. Given that half hour before this error rebuild was at about 40%, I estimated that new drive is not in sync yet and tried to reboot just with Drive 1. RAID controller complained a bit about missing RAID arrays, but it found foreign RAID array on Drive 1 and I imported it. Server booted and it runs (from degraded RAID). Here is SMART data for disks. Drive 0 (the one that failed first) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1 3 Spin_Up_Time POS--K 142 142 021 - 3866 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10432 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 112 106 000 - 31 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 198 000 - 3 And Drive 1 (the drive which was reported healthy from controller until rebuild was attempted) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 35 3 Spin_Up_Time POS--K 143 143 021 - 3841 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10455 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 114 105 000 - 29 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 3 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 In extended error logs from SMART I found: Drive 0 has only one error Error 1 [0] occurred at disk power-on lifetime: 10282 hours (428 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 18 00 00 00 6a 24 20 40 00 Error: IDNF at LBA = 0x006a2420 = 6956064 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 60 00 f8 00 00 00 6a 24 20 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 18 00 60 00 00 00 6a 24 00 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 80 00 58 00 00 00 6a 23 80 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 68 00 50 00 00 00 6a 23 18 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 10 00 10 00 00 00 6a 23 00 40 00 17d+20:25:18.104 WRITE FPDMA QUEUED But Drive 1 has 883 errors. I see only few last ones and all errors I can see look like this: Error 883 [18] occurred at disk power-on lifetime: 10454 hours (435 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 01 -- 51 00 80 00 00 39 97 19 c2 40 00 Error: AMNF at LBA = 0x399719c2 = 966203842 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:57.802 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:57.779 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:55.704 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:55.681 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:53.606 READ FPDMA QUEUED Given those errors, is there any way I can rebuild RAID back, or should I make backup, shutdown server, replace disks with new ones and restore it? What about if I dd faulty disk to new one from linux running on USB/CD? Also, if anyone have more experiences, what could be causes for those errors? Crappy controller or disks? Disks are about 1 year old, but it is pretty unbelievable to me that both would die within so short timespan.

    Read the article