  • Combo ports and SFP

    - by Tahir
    I have Netgear GSM7324s prosafe switch. Switch has 24x1G ports. 4 ports are labeled as combo ports while 2 are labeled as SFP ports. I connected 2 PCs (each having 1gig and 10Gig NICs), with the switch using 1 & 10 Gig cables. Whenever, I ping the PCs the pinging is not working. As soon as, I removed the 10G cables, the ping starts working. Can someone please explain that what's going on. Also it would be very helpful if you can tell me the concept of combo ports, SFP ports in easy words?

    Read the article

  • Baseline 2952-SFP normal?

    - by Atlas
    I just installed a 3com 2952-sfp, and I had its port #48 connected to another gigabit switch through a cat5e cable. Now when I look at the logs, I see the lines shown below: Mar 23 11:20:15:829 2010 MSTP Critical PFWD Instance 0's GigabitEthernet1/0/48 has been set to forwarding state! Mar 23 11:20:15:822 2010 IFNET Warning LINK UPDOWN GigabitEthernet1/0/48: link status is UP Mar 23 11:20:12:974 2010 IFNET Warning LINK UPDOWN GigabitEthernet1/0/48: link status is DOWN The above happens like dozens of times per day, is there something wrong with my setup?

    Read the article

  • where is this SFP problem occuring

    - by Saif Khan
    Hi, Inbound mail to a specific user is been forwarded to his external mailbox at another domain. Add mails are routed correctly with the exception of one domain. When mail are sent to users of my domain, including that user, the mails are delivered to everyone except him...as the mail admin I am getting the message The following recipient(s) cannot be reached: usermailbox on 1/10/2011 1:27 PM There was a SMTP communication problem with the recipient's email server. Please contact your system administrator. email.speedimpex.com #5.5.0 smtp;587 [email protected] sender domain does not match SPF records I am sure this has nothing to do with my mail server, however, can someone confirm?

    Read the article

  • CISCO WS-C4948-10GE SFP+?

    - by Brian Lovett
    I have a pair of CISCO WS-C4948-10GE's that we need to connect to a new switch that has SFP+ and QSFP ports. Is there an X2 module that supports this? If so, can someone name the part number that will work? I have found some information, but want to make sure I have the correct part number for our exact switches. Per the discussion in the comments, I believe I have a better understanding of things now. Would I be correct in saying that I need these SR modules on the cisco side: [url]http://www.ebay.com/itm/Cisco-original-used-X2-10GB-SR-V02-/281228948970?pt=LH_DefaultDomain_0&hash=item417a8d35ea[/url] Then, on the switch with sfp+ ports, I can pick up an SR to SFP+ transceiver like this: [url]http://www.advantageoptics.com/SFP-10G-SR_lp.html?gclid=CKP4s-G27b4CFXQiMgodLD8AQA[/url] and finally, an SR calbe such as this: [url]http://www.colfaxdirect.com/store/pc/viewPrd.asp?idproduct=1551[/url] Am I on the right track here?

    Read the article

  • 10Gbe sfp+ Cross Over Cable required? Is there such a thing?

    - by dc-patos
    To preface, this is my first experience with 10GBe networking and I have encountered an issue which research does not seem to document a solution for... I have two servers (older DL580G5 and DL380G5), each with a HP NC522SFP 10Gbe dual sfp+ port adapter. I have purchased copper "passive" direct connect adapter cables (which look like twinax), which seem to work well when I connect them to the sfp+ ports on my Dell 5524 switch. However, if I directly connect the two servers with the same cable, the link doesn't come up. I am running WS2012 standard on each server. My intention is to use one of these servers as a home brew SAN and I would like to enable mutiple 10Gbe paths for iSCSI traffic. My question(s): Can I connect the two adapters to each other, such as I would with other less speedy generations of ethernet? If I can, do I require a crossover cable, or some type of other sfp+ cable solution to do this? My 10Gbe sfp+ switch ports are premium, but server to server connections are doable in small numbers for me and I would really like the multiple paths this would give me. Is there a simple solution?

    Read the article

  • Problem connecting a 3Com 2952-Plus switch to a Cisco 3750 switch

    - by Noel
    Connected a 3Com 2952-SFP Plus switch to a Cisco 3750 switch via fibre. There is a light on the 3Com end, but nothing at the Cisco end, and no traffic will flow. Have swapped SFP's, have swapped fibre cables, have used a different port on the Cisco, have even swapped the 3Com switch, but still no joy. When I connect a 3Com 2948 switch over fibre that works OK. Any ideas?

    Read the article

  • Networking switch setup

    - by Crash893
    I have two 48 port gigabit netgear switches with 2 SFP ports each (i also have two Mini-GBIC copper transceiver modules) Is it best to set the ports up by using the built in ports (ie plug port 1 of switchB into port 48 of switchA and port1 of switchA into the router) or is there an advantage to using the mini-gbic? (lets call the sfp ports 49 and 50) router - port 49 on switchA, port 50 switchA - port 49 SwitchB

    Read the article

  • Need PHP script to decompress and loop through zipped file.

    - by Jim H.
    I am using a fairly straight-forward script to open and parse several xml files that are gzipped. I also need to do the same basic operation with a ZIP file. It seems like it should be simple, but I haven't been able to find what looked like equivalent code anywhere. Here is the simple version of what I am already doing: $import_file = "source.gz"; $sfp = gzopen($import_file, "rb"); ///// OPEN GZIPPED data while ($string = gzread($sfp, 4096)) { //Loop through the data /// Parse Output And Do Stuff with $string } gzclose($sfp); What would do the same thing for a zipped file?

    Read the article

  • SEO - PageRank on Facebook pages, but pages have no back links to them?

    - by Marco Demaio
    have a look at these two pages: 1) http://it-it.facebook.com/jeanchristophe.cataliotti (PageRank 2 from Google toolbar) Amazingly it has got NO links to it: http://siteexplorer.search.yahoo.com/search?p=it-it.facebook.com/jeanchristophe.cataliotti&fr=sfp 2) http://www.facebook.com/group.php?gid=18463182878&v=wall&viewas=0 (PageRank 1 from Google toolbar) Still amazingly it has got NO links to it: http://siteexplorer.search.yahoo.com/search?p=www.facebook.com/group.php?gid=18463182878&v=wall&viewas=0&fr=sfp How do you explain this? Hoping for an explanation that goes beyond just saying that the PR in Goole toolbar it's not updated, because it can not be the reason for this!

    Read the article

  • looking for a model number recommendation for a network setup of 49 switches [closed]

    - by Bahrain Admin
    im looking to setup a site with 49 edge switches connected by fiber to a central switch. 3 VLANs will be setup to handle data, telephony, and streaming media. each edge switch should have provision for 2 SFP modules for failover, and the core switch needs to have the provision to handle this failover. i'm getting lost on the Cisco site with their specs and recommendations. if anyone could suggest a suitable model number for the core switch and the edge switch, it would be really appreciated.

    Read the article

  • Yahoo search: different results shown in two identical searches

    - by Marco Demaio
    Hello,simple question: searching on http://www.yahoo.it for villa matrimonio bologna I noticed Yahoo shows different results. You need to retry few times to get this done maybe exiting the browser and openeing it again, or maybe searching once and then clearing browser cookies and then search again (it's even easier to test if you use two different browsers at the same time to search for the same phrase). Anyway in order to reproduce this easily I write down here the query shown in the address bar after the search, so you can just click on these to see the results shown by entering these query: http://it.search.yahoo.com/search;_ylt=AirvLYKvBMPP_6MpAmONN14brK5_?vc=&p=villa+matrimonio+bologna&toggle=1&cop=mss&ei=UTF-8&fr=yfp-t-709 http://it.search.yahoo.com/search;_ylt=AirvLYKvBMPP_6MpAmONN14brK5_?vc=&p=villa+matrimonio+bologna&toggle=1&cop=mss&ei=UTF-8&fr=sfp Note the last parameter fr is different, but it's Yahoo that set it (not me), I don't even know what it means. You can see in the search box that the searched phrase is IDENTICAL in both cases. So why Yahoo is giving out different results on same search phrase? I used the same browser and performed the test in few minutes by simply trying more than once. You may also notice that the number of results returned (written on the left side of the page) is different, for the 1st search it returns 274K results, for the 2nd one 5.38M results. Actually you might think that this is just an error on Yahoo, but it's almost 1 year that while looking once in a while at some websites to see how they are ranking on Yahoo and also Google, I noticed that two searches on the same phrase show up different results even on the same day after few minutes/hours. I couldn't reproduce this behaviour also on Google so I can not say for sure, but since it seems to me it happened sometimes I was wondering if anyone of you noticed it too. Do you know if this is the normal behaviour of search engines? Because if it's normal (and it's just me that noticed it only now) I wonder how do you understand how well a site is ranking on a search engine, you could even see one of your customer's website ranking differently compared to what your customer sees on his PC.

    Read the article

  • 1Gigabit vs 1.25Gibabit mismatch

    - by Joel Coel
    I need to re-connect the network to a small old outbuilding that hasn't been used in several years. I have to use the existing 62.5um multi-mode fiber run. This end of the fiber is already connected. For the end in the building, I was looking at this pair: http://www.tp-link.com/products/productDetails.asp?class=switch&content=spe&pmodel=TL-SM311LM http://www.tp-link.com/products/productDetails.asp?class=&content=spe&pmodel=TL-SL2210WEB If you look at the sfp first (first link), it's listed at 1.25Gpbs. That's odd, because IIRC the fiber should really only do 1Gbps. It's also supposed to work with the switch I posted (2nd link), but the gbic port on the switch also only shows 1Gbps. What am I missing here?

    Read the article

  • Are all SFP+ tranceivers usable for FEX between Nexus 5000 and Nexus 2000?

    - by Alain O'Dea
    I am looking at building a network with Nexus 5000 parent switches and Nexus 2000 fabric extenders. The mystery at the moment is what kind of SFP+ tranceivers are required for cross-connecting racks. Right now I am considering FET-10G, but I am not sure that 100m is long enough given the separation between racks is potentially very large since it is a rented rack environment. Are all SFP+ tranceivers usable for FEX between Nexus 5000 and Nexus 2000? Specifically, can SFP-10G-SR transceivers be used for longer distance FEX?

    Read the article

  • Sun Ray 3 Plus Appliance Announced

    - by [email protected]
    There were many of you out there wondering if Oracle was going to keep and add to the Sun Ray and Sun virtualized desktop product suite, there have been a number of affirmative statements over the last many months. However, none of them resound like this; the introduction of a new product pretty much proves the point. A couple minutes before 3:00, local time yesterday, Oracle announced the release of a new Sun Ray, appliance, the Sun Ray 3 Plus. This is the unit that will replace the SR 2 FS (which has been for sale now since the middle of last decade).  Physically it is about the same size as the 2 FS but there are some significant differences... As you can see there is no smart card reader in the front - that has moved to the top to ensure only one hand is required to insert the card.  There is also a larger surround on the card reader that lights up to show the user the card is being read (properly).  A new power on/off switch is on the front which essentially brings power consumption to ~0 watts, but there is also a new 'sleep' timer looking for 30 minutes of inactivity and then will drop the power consumption down to ~ 1watt. There are also 2 USB 2.0 ports are accessible on the front instead of one.  The standard mic in and headphone out ports are there as well.  There is even more interesting stuff on the back. From the top down there are two more USB 2.0 ports for a total of four, but then the Oracle "Peripheral Kit" keyboard includes a 3-port USB Hub, too.  There's a 10/100/1000 Ethernet port as well as a 1000 Mb SFP port.  Standard DB-9 Serial port and then two DVI ports.  Then there is the really big news.  Two DVI ports driving 2560 x 1600 resolution, each. Most PCs can't do that without adding an adapter card.Now the images I have here are ones taken on a prototype a couple months back.  They are essentially the same as the Production unit, but if you would like to see an image of the Production Sun Ray 3 Plus unit you can see one here. There is a full data sheet available here. So this is the first Oracle Sun Ray desktop appliance.  Proof that the product line lives on.  A very good start!

    Read the article

  • NetApp FAS270 head doesn't see disks

    - by wfaulk
    I have an FAS270C. For months, I've been running it in a split-head manner (that is, with each head serving data totally independently, and without any clustering even being enabled) in order to facilitate moving some data around. I finally got everything situated, moved all the data to one of the heads, and was trying to get clustering set back up. Now when I try to install OnTap onto the "new" head, it cannot see any of the disks in the head shelf. (That is, the shelf into which the heads are inserted.) I've booted into maintenance mode, and it shows me that the 0b adapter, which should be the adapter that that shelf and its disks should be presented on, is in "OFFLINE (physical)" state. If I try to enable it with either "storage enable adapter 0b" or "fcadmin online 0b", it waits for about 30 seconds and then says: [fci.initialization.failed:error]: Initialization failed on Fibre Channel adapter 0b. [fci.adapter.online.failed:error]: Fibre Channel adapter 0b failed to come online. There is currently nothing attached to its external 0b port. I've tried it with and without an SFP plugged into it, and with and without its internal termination switch on. The currently active head can see those disks, and can see that two of them are assigned to the other head. Before I started reconfiguring, the "new" head could see disks on that shelf. They may even be the same disks that OnTap was installed on previously. Does anyone have any idea how to proceed?

    Read the article

  • Long Gigabit Ethernet Run

    - by Timothy R. Butler
    I am trying to get an Gig-E network between two buildings that are approximately 260 ft. away. While some TRENDnet switches failed to be able to connect to each other over Cat 6 at that distance, two Netgear 5-port Gig-E switches do so just fine. However, it still fails after I put in place APC PNET1GB ethernet surge protectors at each end before the line connects to the respective switches. So I find myself wondering if I simply need to find a better surge protector that doesn't degrade the signal as much (if so, what kind would you recommend?) or if I should give up on copper and use fiber between the buildings. If I opt to go the latter route, I could really use some pointers. It looks like LC connectors are the most common, but I keep running into some others as well. A media converter on each end seems like the simplest solution, but perhaps a Gig-E switch with an SFP port would make more sense? Given a very limited budget, sticking with my existing copper seems best, but if it is bound to be a headache, a 100 meter fiber cable is something I think I can swing cost wise.

    Read the article

  • NTOP gives warnings on startup

    - by FR6
    I just installed ntop 1.4.4 and when I start it, it give me infinite warnings "packet truncated": ... RRD_DEBUG: umask 0066 RRD_DEBUG: DirPerms 0700 THREADMGMT: RRD: Started thread (t2992630672) for data collection THREADMGMT[t2992630672]: RRD: Data collection thread starting [p30923] INIT: Created pid file (/var/run/ntop.pid) THREADMGMT[t3086329552]: ntop RUNSTATE: INITNONROOT(3) Now running as requested user 'nobody' (99:99) Note: Reporting device initally set to 0 [eth0] (merged) THREADMGMT[t3086329552]: ntop RUNSTATE: RUN(4) THREADMGMT[t2982140816]: NPS(1): Started thread for network packet sniffing [eth0] THREADMGMT[t2982140816]: NPS(eth0): pcapDispatch thread starting [p30923] THREADMGMT[t2982140816]: NPS(eth0): pcapDispatch thread running [p30923] THREADMGMT[t3047009168]: SIH: Idle host scan thread running [p30923] THREADMGMT[t3057499024]: SFP: Fingerprint scan thread running [p30923] **WARNING** packet truncated (8814->8232) **WARNING** packet truncated (10274->8232) **WARNING** packet truncated (8814->8232) **WARNING** packet truncated (8814->8232) ... Do I need to configure something? I tried to access the web interface (http://localhost:3000) but it does not work. Note: I'm on CentOS. EDIT: Not sure if it helps but there is my "ifconfig": eth0 Link encap:Ethernet HWaddr 00:16:76:BC:7E:77 inet addr:192.168.0.221 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::216:76ff:febc:7e77/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:15496640 errors:0 dropped:0 overruns:0 frame:0 TX packets:19256813 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:836230629 (797.4 MiB) TX bytes:608496148 (580.3 MiB) Memory:dffe0000-e0000000

    Read the article

  • NTOP gives warnings on startup

    - by FR6
    I just installed ntop 1.4.4 and when I start it, it give me infinite warnings "packet truncated": ... RRD_DEBUG: umask 0066 RRD_DEBUG: DirPerms 0700 THREADMGMT: RRD: Started thread (t2992630672) for data collection THREADMGMT[t2992630672]: RRD: Data collection thread starting [p30923] INIT: Created pid file (/var/run/ntop.pid) THREADMGMT[t3086329552]: ntop RUNSTATE: INITNONROOT(3) Now running as requested user 'nobody' (99:99) Note: Reporting device initally set to 0 [eth0] (merged) THREADMGMT[t3086329552]: ntop RUNSTATE: RUN(4) THREADMGMT[t2982140816]: NPS(1): Started thread for network packet sniffing [eth0] THREADMGMT[t2982140816]: NPS(eth0): pcapDispatch thread starting [p30923] THREADMGMT[t2982140816]: NPS(eth0): pcapDispatch thread running [p30923] THREADMGMT[t3047009168]: SIH: Idle host scan thread running [p30923] THREADMGMT[t3057499024]: SFP: Fingerprint scan thread running [p30923] **WARNING** packet truncated (8814->8232) **WARNING** packet truncated (10274->8232) **WARNING** packet truncated (8814->8232) **WARNING** packet truncated (8814->8232) ... Do I need to configure something? I tried to access the web interface (http://localhost:3000) but it does not work. Note: I'm on CentOS. EDIT: Not sure if it helps but there is my "ifconfig": eth0 Link encap:Ethernet HWaddr 00:16:76:BC:7E:77 inet addr:192.168.0.221 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::216:76ff:febc:7e77/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:15496640 errors:0 dropped:0 overruns:0 frame:0 TX packets:19256813 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:836230629 (797.4 MiB) TX bytes:608496148 (580.3 MiB) Memory:dffe0000-e0000000

    Read the article

  • Cisco Access switch is dropping large amount of end points

    - by user135458
    This afternoon, with no changes to the network, a switch suddenly started dropping off lots of connections. These connections would come back up a few minutes later, then another area connected to the switch would drop off. This is an older 4006 chassis switch which could in and of itself be a problem but I'm looking to see what else you all would look for in trying to find a root cause. Switch is connected via ports 1/1 and 1/2 in an etherchannel to a VSS core 1/1/42 and 2/1/42. Both sides are up and working however the CPU on the switch will spike up to 99% and that's when CRC errors start to hit the VSS core on one of those interfaces and end points start dropping off. We tried new transceivers and SFP's on each side of the link, same result. When we tried swapping the fiber patch cables on the access switch the CRC errors did not follow the fiber cables they stayed with port 1/2 on the access switch. So port 1/2 on the supervisor module looks like the culprit. We actually tried to create a new member of the ethernet channel by taking a fiber media converter to cat5 and make that a member of the port-channel but when we plugged it in you couldn't even reach the switch. I'm guessing that's unrelated and a problem with the media converter. As of right now we have left it in a state of only one fiber cable running to one side of the VSS core (1/1 Access Switch -- 2/1/42). I've sent some info into TAC and they are looking into the situation but does anyone else have any commands I could run or some troubleshooting I could look into in the meantime?

    Read the article

  • Issues getting a Cisco WLC 5508 to find AIR-LAP1142N

    - by user95917
    hoping someone can help me with a problem here. I'm attempting to setup a test (loan from Cisco) wireless network. Here's what i've got/done: 5508 Controller - Service Port IP set to 10.74.5.2 /24. Management IP set to 10.74.6.2 /24 with a default gateway of 10.74.6.1. Virtual IP set to 1.1.1.1. Copper SFP in slot 7, CAT5 (known good) going from there to port 1/0/47 on the switch. Green lights on both ends. 2960-S Switch - Vlan1 - 10.74.6.1 /24. dhcp pool 10.74.6.0 /24, default router 10.74.6.1. excluded-address 10.74.6.1, 10.74.6.2. 1/0/4 on the switch is set to switchport mode access and no shut. 1/0/47 on the switch is setup to switchport mode trunk and no shut. 1/0/4 has a CAT5 (known good) cable going from there to the AP. When I do a sh cdp nei from the switch, i can see the AP and Controller listed. When i configure my PC's nic to 10.74.5.5, and plug a cable from my nic to the SP port on the controller i can get on the device via the gui. In there, the only errors/info that show up in the trap are: Link Up: Slot: 0 Port: 7 Controller time base status - Controller is out of sync with the central timebase. I've manually set the time but apparently that's not quite the problem (or at least not the entire problem). When i plug the AP in, i see on the switch console that it grants it power, it sees it connect...but the controller won't see it for some reason. From what i've read you shouldn't have to do anything to the AP as it's managed by the controller...but i'm not sure what setting I'm missing for it to work. The AP light on top is continually cycling green, red, yellow. When I first start it up, it blinks green for 20 or so seconds, then goes to solid green for another 20 seconds or so, then flashes blue, green, red for awhile...but always ends up goinn back to the standard, green, red, yellow. Does anyone see any obvious issues with my setup or have any suggestions as to why i might be having a problem? Thanks for your help!

    Read the article

  • Configure spanning tree from HP to Cisco hardware

    - by Tim Brigham
    I have three switches I'd like to configure in a loop - a Cisco stack (3750s) and two HP 2900 series. Each is connected to the next with a 10 gig backplane of one form or another. How do I configure the spanning tree on these systems to make this function correctly? From the documents I've looked at it looks like I need to set both sets of hardware to use MST mode but I'm not sure past that point. The trunking, etc is all set up as needed. HP Switch 1 A4 connected to Cisco 1/0/1. HP Switch 2 B2 connected to Cisco 2/0/1. HP Switch 1 A2 connected to HP Switch 2 A1. HP Switch 1 show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 1-4094 Switch MAC Address : 0021f7-126580 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 352,485 Time Since Last Change : 2 secs CST Root MAC Address : 0018ba-c74268 CST Root Priority : 1 CST Root Path Cost : 200000 CST Root Port : 1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 0 IST Remaining Hops : 20 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- ... A1 | Auto 128 Disabled | A2 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A3 10GbE-CX4 | Auto 128 Disabled | A4 10GbE-SR | 2000 128 Forwarding | 0021f7-126580 2 Yes No HP Switch 2 show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 1-4094 Switch MAC Address : 0024a8-cd6000 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 19,623 Time Since Last Change : 32 secs CST Root MAC Address : 0018ba-c74268 CST Root Priority : 1 CST Root Path Cost : 202000 CST Root Port : A1 IST Regional Root MAC Address : 0024a8-cd6000 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 0 IST Remaining Hops : 20 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- ... A1 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A2 10GbE-CX4 | Auto 128 Disabled | B1 SFP+SR | 2000 128 Blocking | a44c11-a67c80 2 Yes No B2 | Auto 128 Disabled | Cisco Stack 1 show spanning-tree ... (additional VLANs) VLAN0100 Spanning tree enabled protocol ieee Root ID Priority 1 Address 0018.bac7.426e Cost 2 Port 107 (TenGigabitEthernet2/1/1) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32868 (priority 32768 sys-id-ext 100) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 300 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Desg FWD 2 128.53 P2p Te2/1/1 Root FWD 2 128.107 P2p

    Read the article

  • HP to Cisco spanning tree root flapping

    - by Tim Brigham
    Per a recent question I recently configured both my HP (2x 2900) and Cisco (1x 3750) hardware to use MSTP for interoperability. I thought this was functional until I applied the change to the third device (HP switch 1 below) at which time the spanning tree root started flapping causing performance issues (5% packet loss) between my two HP switches. I'm not sure why. HP Switch 1 A4 connected to Cisco 1/0/1. HP Switch 2 B2 connected to Cisco 2/0/1. HP Switch 1 A2 connected to HP Switch 2 A1. I'd prefer the Cisco stack to act as the root. EDIT: There is one specific line - 'spanning-tree 1 path-cost 500000' in the HP switch 2 that I didn't add and was preexisting. I'm not sure if it could have the kind of impact that I'm describing. I'm more a security and monitoring guy then networking. EDIT 2: I'm starting to believe the problem lies in the fact that the value for my MST 0 instance on the Cisco is still at the default 32768. I worked up a diagram: This is based on every show command I could find for STP. I'll make this change after hours and see if it helps. Cisco 3750 Config: version 12.2 spanning-tree mode mst spanning-tree extend system-id spanning-tree mst configuration name mstp revision 1 instance 1 vlan 1, 40, 70, 100, 250 spanning-tree mst 1 priority 0 vlan internal allocation policy ascending interface TenGigabitEthernet1/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface TenGigabitEthernet2/1/1 switchport trunk encapsulation dot1q switchport mode trunk ! interface Vlan1 no ip address ! interface Vlan100 ip address 192.168.100.253 255.255.255.0 ! Cisco 3750 show spanning tree: show spanning-tree MST0 Spanning tree enabled protocol mstp Root ID Priority 32768 Address 0004.ea84.5f80 Cost 200000 Port 53 (TenGigabitEthernet1/1/1) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32768 (priority 32768 sys-id-ext 0) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Root FWD 2000 128.53 P2p MST1 Spanning tree enabled protocol mstp Root ID Priority 1 Address a44c.11a6.7c80 This bridge is the root Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 1 (priority 0 sys-id-ext 1) Address a44c.11a6.7c80 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- -------------------------------- Te1/1/1 Desg FWD 2000 128.53 P2p Cisco 3750 show logging: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan100, changed state to up %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up HP Switch 1: ; J9049A Configuration Editor; Created on release #T.13.71 vlan 1 name "DEFAULT_VLAN" untagged 1-8,10,13-16,18-23,A1-A4 ip address 100.100.100.17 255.255.255.0 no untagged 9,11-12,17,24 exit vlan 100 name "192.168.100" untagged 9,11-12,17,24 tagged 1-8,10,13-16,18-23,A1-A4 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A4 no ip address exit vlan 40 name "Cafe" tagged 1,4,7,A1-A4 no ip address exit vlan 250 name "Firewall" tagged 1,4,7,A1-A4 no ip address exit vlan 70 name "DMZ" tagged 1,4,7-8,13,A1-A4 no ip address exit spanning-tree spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 password manager password operator HP Switch 1 show spanning tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0021f7-126580 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 363,490 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : 1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 0 IST Remaining Hops : 20 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 | Auto 128 Disabled | A2 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A3 10GbE-CX4 | Auto 128 Disabled | A4 10GbE-SR | Auto 128 Disabled | HP Switch 1 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00842 stp: MSTI 1 starved for an MSTI Msg Rx on port A4 from 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to 32768:0021f7-126580 00839 stp: MSTI 1 Root changed from 32768:0021f7-126580 to 0:a44c11-a67c80 00839 stp: MSTI 1 Root changed from 0:a44c11-a67c80 to ... HP Switch 2 Configuration: ; J9146A Configuration Editor; Created on release #W.14.49 vlan 1 name "DEFAULT_VLAN" untagged 1,3-17,21-24,A1-A2,B2 ip address 100.100.100.36 255.255.255.0 no untagged 2,18-20,B1 exit vlan 100 name "192.168.100" untagged 2,18-20 tagged 1,3-17,21-24,A1-A2,B1-B2 no ip address exit vlan 21 name "Users_2" tagged 1,A1-A2,B2 no ip address exit vlan 40 name "Cafe" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 250 name "Firewall" tagged 1,13-14,16,A1-A2,B2 no ip address exit vlan 70 name "DMZ" tagged 1,13-14,16,A1-A2,B2 no ip address exit logging 192.168.100.18 spanning-tree spanning-tree 1 path-cost 500000 spanning-tree config-name "mstp" spanning-tree config-revision 1 spanning-tree instance 1 vlan 1 40 70 100 250 HP Switch 2 Spanning Tree: show spanning-tree Multiple Spanning Tree (MST) Information STP Enabled : Yes Force Version : MSTP-operation IST Mapped VLANs : 2-39,41-69,71-99,101-249,251-4094 Switch MAC Address : 0024a8-cd6000 Switch Priority : 32768 Max Age : 20 Max Hops : 20 Forward Delay : 15 Topology Change Count : 21,793 Time Since Last Change : 14 hours CST Root MAC Address : 0004ea-845f80 CST Root Priority : 32768 CST Root Path Cost : 200000 CST Root Port : A1 IST Regional Root MAC Address : 0021f7-126580 IST Regional Root Priority : 32768 IST Regional Root Path Cost : 2000 IST Remaining Hops : 19 Root Guard Ports : TCN Guard Ports : BPDU Protected Ports : BPDU Filtered Ports : PVST Protected Ports : PVST Filtered Ports : | Prio | Designated Hello Port Type | Cost rity State | Bridge Time PtP Edge ----- --------- + --------- ---- ---------- + ------------- ---- --- ---- A1 10GbE-CX4 | 2000 128 Forwarding | 0021f7-126580 2 Yes No A2 10GbE-CX4 | Auto 128 Disabled | B1 SFP+SR | 2000 128 Forwarding | 0024a8-cd6000 2 Yes No B2 | Auto 128 Disabled | HP Switch 2 Logging: I removed the date / time fields since they are inaccurate (no NTP configured on these switches) 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80 00839 stp: IST Root changed from 32768:0021f7-126580 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0004ea-845f80 00839 stp: CST Root changed from 32768:0004ea-845f80 to 32768:0024a8-cd6000 00435 ports: port B1 is Blocked by STP 00839 stp: CST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: IST Root changed from 32768:0024a8-cd6000 to 32768:0021f7-126580 00839 stp: CST Root changed from 32768:0021f7-126580 to 32768:0004ea-845f80

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article