Search Results

Search found 12 results on 1 pages for 'thed'.

Page 1/1 | 1 

  • Virtual Disk Degraded

    - by TheD
    There is a physical DC with a Raid 1 Mirror, 2 Physical Disks, 500GB each. Dell Server Administrator is installed on the DC, and is reporting both physical disks are fine, online, in a good state etc. On a PERC S300 Raid Controller: Physical Disk 0:0 Physical Disk 0:1 However at the same time it's reporting that a virtual disk is degraded, what exactly does this mean? The virtual disk indicates it's State is in a Raid 1 Layout. Device Name: Windows Disk 0 If my understanding is correct then the Virtual Disk, when you drill down into Dell OpenManage should have both physical disks as members, as it is a mirror? Is this correct? However, when I drill down into the Virtual Disk, it only displays Physical Disk 0:0 included in Virtual Disk 1. I'm very new to server side/raid management etc. just while our server techy is away! Thanks!

    Read the article

  • Sophos UTM in Hyper-V

    - by TheD
    So, I had a previous thread about this Virtualizing Firewalls/UTM. Essentially, I have configured what I think would work, but networking isn't my strong point! Two Virtual Adapters - with IP addresses 192.168.0.2 (External) and 192.168.0.3 (Internal) respectively. The External Adapater looks at 192.168.0.1 (my Zyxel) for it's default gateway. The Internal Adapter, 192.168.0.3, which is what the Sophos UTM listens on, has it's default gateway set to 192.168.0.2, the IP of the External Lan interface. So, PC (192.168.0.11, DHCP) --> (LAN) --> Switch --> 192.168.0.3 (Internal LAN Interface IP) --> Sophos UTM --> 192.168.0.2 (External LAN Interface IP) --> 192.168.0.1 --> Internet Would this be the correct setup, or am I completely out of the game here? Cheers!

    Read the article

  • Server Restart's and Respective Orders

    - by TheD
    EDIT:Not meaning to be disrespectful to any of the answers, but, the main question was whether rebooting a DC at the beginning of a cycle, then all the other servers, or rebooting it at the end once all the others are back online - is there a reason for doing it either way? I'm still not sure based on current responses. This will most likely seem like a fairly, maybe even stupid, question, but it's something I have been wondering about. As part of a regular process for clients servers are restarted remotely after patches and every client tends to have a similar order - but there always seems to be a small debate when it comes down to when do you reboot your DC. For example, 4 servers, 1 DC, 1xExchange, 1xBESX and 1xRandom, lets say it has some CRM software installed, is it best to reboot the DC first, then Exchange, then BESX and so on - or reboot all the servers, then reboot the DC last? - Perhaps it doesn't matter at all and it's just a case of how you have always done it. Would it change in a Hyper-V environment for example, with a physical DC, 1 VHost with all your servers virtualised on that Host? Rebooting the VHost and Virtual Machines first, then the DC at the end, or vice versa? Thanks!

    Read the article

  • Static Routes and the Routing Table

    - by TheD
    This is very much a learning question if someone would be happy to explain a couple of concepts. My question is - the default routing table that exists in, in my case, a default Windows 7 install, what do each of the routes in the table do? Here is a screenshot: The 10.128.4.0 is just a route I've added while messing. I understand from a question I posted on Superuser the first route is just a default route that will route all traffic for any IP to my default gateway on my Interface in use. But what about the others? And how would the routing table handle a machine with multiple NIC's, perhaps connected to two different networks, or maybe even two NIC's on the same network so a VM can have a physical Network card instead of each VM sharing the hosts. Thanks!

    Read the article

  • BT socket Device over Structured Cabling

    - by TheD
    Not sure if this is the right stack* site to post on but I believe cabling is a just subject. Essentially I have a Credit Card machine which is connected to a phone line via standard BT Socket. So basically, the port of the wall has a balun plugged in which takes the RJ45 outlet on the wall to BT, so I can plug the device in. This works fine, however I need the machine to be on the other side of the room so want to route it through my patch panel (strucutered cabling). How can this be done? So Device -- ? -- RJ45 port -- Patch Panel -- ? -- Balun out wall outlet Where ? is to be filled in ! :)

    Read the article

  • DHCP for Multiple Subnets

    - by TheD
    So this is the current setup - essentially I would like to get my DHCP server, serving DHCP requests for two seperate subnets. Netgear DG834G acting as a modem connected to a Sonicwall Pro 2040. X0 - LAN - 192.168.1.0/24 X1 - WAN - <WAN-IP> X2 - WLAN - 192.168.10.0/24 At the moment, I have a 2008R2 server with DHCP installed, with an IP address on the 192.168.1.0/24 range handling DHCP fine for this subnet. The Sonicwall is configured correctly - anything connected to the WLAN has Full Allow to anything in the LAN, and vice versa but it will not lease an IP from my Server. I've also added another IP address to the server, so the physical NIC now has two IP's: 192.168.1.2 and 192.168.10.2 with a DHCP scope configured for each. Still no luck! Any ideas? Thanks!

    Read the article

  • WBAdmin SystemState Problems

    - by TheD
    I recently installed DHCP on my 2008R2 Server and now Backup Exec and WBAdmin/WSB is having System State issues. Essentially, after some research, I came across a handy tool called VSHADOW which has allowed me to output all the files (and their respective directories) to a text file. And hooray, I think I found the problem: * WRITER "Dhcp Jet Writer" - WriterId = {be9ac81e-3619-421f-920f-4c6fea9e93ad} - InstanceId = {0ed0a8f4-19b0-414d-a3a8-d51d6f4ac8e0} - Supports restore events = TRUE - Writer restore conditions = VSS_WRE_IF_REPLACE_FAILS - Restore method = VSS_RME_RESTORE_AT_REBOOT - Requires reboot after restore = TRUE - Excluded files: - Component "Dhcp Jet Writer:\C:_Windows_system32_dhcp\dhcp" - Name: 'dhcp' - Logical Path: 'C:_Windows_system32_dhcp' - Full Path: '\C:_Windows_system32_dhcp\dhcp' The logical path and Full Path for DHCP is completely wrong. However I can't find where I would change this path, I assume in the registry but I've had no luck finding the key !

    Read the article

  • Virtualizing Firewalls/UTM

    - by TheD
    So Sophos UTM (Astaro Gateway UTM) can be virtualized in Hyper-V, VMWare, vSphere etc. Now I'm new to virtualization, so am wondering how the networking would be configured in this situation. Imagine the following (a very simple setup). A Zyxel router acting as the default gateway, standard ADSL line. This is connected directly via Ethernet to my VHost, Hyper-V in my case. Now I assume I need two virtual network adapters, one which is the "External" interface to the firewall, and the other being the "Internal" interface. But where does my switch go, since I have 5 machines (or X number of machines). Where is the switch connected, to the internal interface on the VHost? What default gateway do my clients use etc? How would the routing work if these two interfaces weren't bridged since they are virtual networks anyway. I'm a little confused! Any advice is much appreciated! Cheers

    Read the article

  • How Exchange integrates with DC

    - by TheD
    This probably is a very open ended question, but really I'm only looking for a specific aspect I suppose. It relates to a reboot question I posted earlier, relating to restart orders of servers, Server Restart's and Respective Orders. Please take a look if you get a second for input! Basically - in relation to how Exchange integrates with AD, what would happen in two scenarios: 1). The Exchange server is booted up before the DC is online 2). You replace a DC but keep your current Exchange server. I'm fairly new to all of this, so hopefully this isn't a silly question (I'm an apprentice in fact!). Many thanks

    Read the article

  • CD-R suddenly unreadable?

    - by TheD
    I have a CD-R which has worked fine for a good while. All of a sudden, Windows can no longer read its data. It's not scratched, it's clean and Windows can detect the disk and usage of space on it. But whenever I attempt to access the data stored: Explorer crashes Or after 5-10 mins of trying to read it, it opens up and just shows a desktop.ini file in Explorer. This happens on multiple machines. Any ideas? Is there a way to recover the data? For example - some sector by sector recovery software if any exist for CD's?

    Read the article

  • Powershell - Splitting string into seperate components

    - by TheD
    I am writing a script which will basically do the following: Read from a text file some arguements: DriveLetter ThreeLetterCode ServerName VolumeLetter Integer Eg. W MSS SERVER01 C 1 These values happen to form a folder destination W:\MSS\, and a filename which works in the following naming convention: SERVERNAME_VOLUMELETTER_VOL-b00X-iYYY.spi - Where The X is the Integer above The value Y I need to work out later, as this happens to be the value of the incremental image (backups) and I need to work out the latest incremental. So at the moment -- Count lines in file, and loop for this many lines. $lines = Get-Content -Path PostBackupCheck-Textfile.txt | Measure-Object -Line for ($i=0; $i -le $lines.Lines; $i++) Within this loop I need to do a Get-Content to read off the line I am currently looking at i.e. line 0, line 1, line 2, as there will be multiple lines in the format I wrote at the beginning and split the line into an array, whereby each part of the file, as seen above naming convention, is in a[0], a[1], a[2]. etc The reason for this is because, I need to then sort the folder that contains these, find the latest file, by date, and take the _iXXX.spi part and place this into the array value a[X] so I then have a complete filename to mount. This value will replace iYYY.spi It's a little complex because I also have to make sure when I do a Get-ChildItem with -Include before I sort it all by date, I am only including the filename that matches the arguements fed to it from the text file : So, SERVER01_C_VOL-b001-iYYY.spi and not anything else. i.e. not SERVER01_D_VOL-b001-iYYY.spi Then take the iYYY value from the sort on the Get-ChildItem -Include and place that into the appropriate array item. I've literally no idea where to start, so any ideas are appreciated! Hopefully I've explained in enough detail. I have also placed the code on Pastebin: http://pastebin.com/vtFifTW6 Thanks!

    Read the article

  • Powershell - Using variables in -Include filter

    - by TheD
    (again!) My final question for the night. I have a function which uses the Get-ChildItem to work out the newest file within a folder. The reason being I need to find the latest incremental backup in a folder and script an EXE to mount it. However, within this same folder there are multiple backup chains for all different servers: i.e. SERVER1_C_VOL_b001_i015.spi SERVER2_D_VOL_b001_i189.spi SERVER1_C_VOL_b002_i091.spi SERVER1_E_VOL_b002_i891.spi (this is the newest file created) I want only to look at SERVER1, look at only the C_VOL and look at only b001 - nothing else. I have all these seperate components: the drive letter, the Server Name, the b00X number stored in array. How then can I go and use the Get-ChildItem with the -Include filter to only look at: .spi SERVER1 C_VOL b001 Given I have all of these separate components in an array taken from a text file: Get-Content .\PostBackupCheck-TextFile.txt | Select-Object -First $i { $a = $_ -split ' ' ; $locationArray += "$($a[0]):\$($a[1])\$($a[2])" ; $imageArray += "$($a[2])_$($a[3])_VOL_b00$($a[4])_i$($a[5]).spi" } I then go onto try and filter then and then get stuck: $latestIncremental = Get-ChildItem -Path ${shadowProtectDataLocation}\*.* -Include *.spi | Sort-Object LastAccessTime -Descending | Select-Object -First 1 I have the .spi filtered, but how can I also just include the C (for volume), the number for the b00x and the server name. Thanks!

    Read the article

1