  • EMC VNX iSCSI setup - unsure about SP/port assignment

    - by pauska
    We have a new VNX5300 waiting to get configured, and I need to plan out the network infrastructure before the EMC tech arrives. It has 4x1gbit iSCSI per SP (8 ports in total), and I'd like to get the most out of the performance until we jump over to 10gig iSCSI. From what I can read from the docs - the recommendation is to use only two ports per SP, with 1 active and 1 passive. Why is this? It seems kind of pointless to have quad-port i/o-modules and then recommend to not use more than two of them? Also - I'm a bit unsure about the zoning. The best practices guide state that you should separate each port on each SP from each other on different logical networks. Does this mean that I have to create 4 logical networks to be able to use all 8 ports? It also gives the following example: Does this mean that A0 and B0 should sit on the same physical switch aswell? Won't this make all traffic go on one switch (if both A1 and B1 are passive)? Edit: Another brainpuzzle I don't get it - each host (as in server) should not have more iSCSI bandwidth available than the storage processor. What on earth does this matter? If serverA have 1gbit and serverB have 100mbit, then the resulting bandwith between them is 100mbit. How can this result in some kind of oversubscription? Edit4: Wait, what. Active and passive ports? The VNX runs in a ALUA configuration with asymmetrical active/active.. there shouldn't be any passive ports, only preferred ones..

    Read the article

  • Strange Exchange 2010 Mailbox issues

    - by jmreicha
    A little bit of information on my environment. I have 2 Exchange 2010 mailbox servers setup in a DAG, connected to a VNX SAN via fiber for the mailbox database disks. One of the servers seems to be working fine as it isn't throwing any similar errors but the other has been receiving strange errors in Event Viewer. I haven't been able to find a pattern to when these happen and I'm not really sure what I should be looking at to troubleshoot this. At this point I am wondering if the issue resides on the SAN or if this is because of an improper shutdown or something else on the Exchange side of things? Here are a few of the errors if that helps:

    Read the article

  • what do you use for storage discovery / storage management?

    - by lysdexic
    I am looking for some ideas on what would be the best way to discover and manage network storage. Discovery: Any good tools that will scan hosts and storage devices and report back their findings? Maybe using SNMP or WMI? Management: I'm currently looking at Storage Manager by Solar Winds, but it is a bit pricey. Any good open source projects like this? Just looking for ideas of how to get better visibility into the storage infrastructure on this network. It includes a HP Lefthand Iscsi san and EC VNX san. As well as individual hosts with local storage. Thanks for reading and thanks for any input.

    Read the article

  • A dusty server room

    - by pauska
    Here's the story.. The owners of the building we lease office space from decided to do a renovation of the exterior. This involved in some pretty heavy work at the level where our server room is, including exchanging windows wich are fit inside a concrete wall. My red alert went off when I heard that they were going to do the same thing with our server room (yes, our server room has a window. We're a small shop with 3 racks. The window is secured with steel bars.) I explicity told the contractor that they need to put up a temporarily wall between our racks and the original wall - and to make sure that the temporary wall is 100 % air and water-tight. They promised to do so. The temporary wall has a small door in it, so that workers can go in/out through the day (through our server room, wich was the only option....). On several occasions I could find the small door half-way shut while working evenings/nights. I locked the door, and thought that they would hopefully get the point soon and keep the door shut. I even gave a electrician a mouthful when I saw that he didn't close the door properly. By this point - I bet that most of you get a picture of what happened. Yes, they probably left the door open while drilling in the concrete. I present you our 4 weeks old EMC VNX: I'll even put in a little bonus, here is the APC UPS one rack further away from the temporary wall. See the nice little landing strip from my finger? What should I do? The only thing that comes to mind is to either call all our suppliers (EMC, HP, Dell, Cisco) and get them to send technicians to check out all the gear in the server room, or get some kind of certified 3rd-party consulant to check all of it. Would you run production systems on this gear? How long? Edit: I should also note that our aircondition isn't exactly enterprise-grade, given the nature of our small room. It's just a single inverter, wich have failed one time before I started working here (failed inverters usually leads to water dripping out).

    Read the article