Search Results

Search found 54 results on 3 pages for 'wix3 6'.

Page 1/3 | 1 2 3  | Next Page >

  • Using wix3 SqlScript to run generated temporary sql-script files.

    - by leiflundgren
    I am starting to write an installer which will use the SqlScript-element. That takes a reference to the Binary-table what script to run. I would like to dynamically generate the script during the installation. I can see three possibilities: Somehow to get SqlScript to read it data from a file rather then a Binary entry. Inject my generated script into the Binary table Using SqlString Which will cause the need to place some rather long strings into Properties, but I guess that shouldn't really be a prolem. Any advice? Regards Leif (My reason, should anyone be interested is that the database should have a job set up, that calls on an installed exe-file. I prefer to create the job using sqlscript. And the path of that file is not known until InstallDir has been choosen.)

    Read the article

  • WiX - Modifying an existing service to be dependent on the service I am installing

    - by Paul Nearney
    Hi all, Using Wix3, its trivial to ensure that a windows service being installed is given a dependency on a service that is already installed on the target machine, but I need to do the opposite - i.e. as part of my install I need to modify the service dependencies of an existing service (i.e. already installed on the target machine), to ensure that that service is dependent on the service I am installing. Is there a simple way to do this using WiX? or will I need to write a custom action? Many thanks, Paul

    Read the article

  • Change Wix Merge Module Package GUID?

    - by jenglert
    When is it necessary to change the package GUID of a merge module? <Wix xmlns="http://schemas.microsoft.com/wix/2006/wi"> <Module Id="MyMergeModule" Language="1003" Version="1.0.0.0"> <Package Id="SOME_GUID" Manufacturer="Me" InstallerVersion="301" /> </Module> </Wix> Wix3 requires that the package GUID is explicitly specified for a merge module unlike for a product. My merge module will be used with an MSI that is built bi-weekly. These bi-weekly MSIs need to co-exist on the same machine as separate installations (e.g. versions 1, 2, 3, etc...) Do I need to change the package GUID of my merge module for each bi-weekly MSI build?

    Read the article

  • WiX 3: Using heat.exe to add bulk files to a new WiX project: HEAT5150

    - by Karen Kwong
    If this is a repeat question, please direct me to the existing solution. I wasn't able to find a matching query. We currently use InstallShield. I'm attempting to covert a project with 407 files to a WiX3 installation package. I tried using heat.exe to do some of the automation but I get the following warning for almost every file: c: heat dir "c:\projectDir\projectA" -gg -ke -template:Product -out "c:\install\projectA\heatOutput" heat.exe: warning HEAT5150 : Could not harvest data from a file that was expected to be a SelfReg DLL: c:\projectDir\projectA\plugin1.dll. If this file does not support SelfReg you can ignore this warning. Otherwise, this error detail may be helpful to diagnose the failure: Unable to load file: c:\projectDir\projectA\plugin1.dll, error: 126. Q: Is it normal for this warning to be reported for every file? If there's a current "How To create/convert to your first WiX install project with many files" tutorial, please point me to it. The key requirement is "with many files". Thank-you -Karen Kwong- PS. I know that WiX is designed for incremental install project creation but it would be nice to know if there's an automated way to convert existing install projects.

    Read the article

  • Wix, Launch application after installation complete, with UAC turned on.

    - by Christopher Roy
    Good day. I've been building an installer for our product using the WIX(Windows Installer XML) technology. The expected behavior is that the product is launched, if the check box is checked after installation. This has been working for some time now, but we found out recently that UAC of Win 7, and Vista is stopping the application from launching. I've done some research and it has been suggested to me that I should add the attributes Execute='deferred' and Impersonate='no'. Which I did, but then found out that to execute deferred, the CustomAction has to be performed, between the InstallInitialize, and IntallFinalize phases; which is not what I need. I need the product to launch AFTER install finalize, IF the launch checkbox is checked. Is there any other way to elevate permissions? Any and all answers, suggestions, or resonings will be appreciated. Cheers, Christopher Roy.

    Read the article

  • WiX tricks and best practices

    - by Si
    We've been using WiX 3 for a while now, and despite the usual gripes about ease of use, it's going reasonably well. What I'm looking for is useful advice regarding: Setting up a WiX project (layout, references, file patterns) Integrating WiX into solutions, and build/release processes Configuring installers for new installations and upgrades Also interested in any good WiX hacks you'd like to share, thanks!

    Read the article

  • WiX unresolved reference error

    - by David
    I'm using Wix version 3.0.5419.0. I have two .wxs files, one which is a fragment, and another which uses the fragment to create the .msi file. Here is the file which uses the fragment (DaisyFarmer.wxs): <?xml version='1.0' encoding='windows-1252'?> <Wix xmlns='http://schemas.microsoft.com/wix/2006/wi' xmlns:iis='http://schemas.microsoft.com/wix/IIsExtension'> <Product Name='Daisy Web Site 1.0' Id='BB7FBBE4-0A25-4cc7-A39C-AC916B665220' UpgradeCode='8A5311DE-A125-418f-B0E1-5A30B9C667BD' Language='1033' Codepage='1252' Version='1.0.0' Manufacturer='the man'> <Package Id='5F341544-4F95-4e01-A2F8-EF74448C0D6D' Keywords='Installer' Description="desc" Manufacturer='the man' InstallerVersion='100' Languages='1033' Compressed='yes' SummaryCodepage='1252' /> <Media Id='1' Cabinet='Sample.cab' EmbedCab='yes' DiskPrompt="CD-ROM #1" /> <Property Id='DiskPrompt' Value="the man" /> <PropertyRef Id="NETFRAMEWORK35"/> <Condition Message='This setup requires the .NET Framework 3.5.'> <![CDATA[Installed OR (NETFRAMEWORK35)]]> </Condition> <Feature Id='DaisyFarmer' Title='DaisyFarmer' Level='1'> <ComponentRef Id='SchedulerComponent' /> </Feature> </Product> </Wix> The fragment I'm referencing is (Scheduler.wxs): <?xml version="1.0" encoding="utf-8"?> <Wix xmlns="http://schemas.microsoft.com/wix/2006/wi"> <Fragment> <DirectoryRef Id="TARGETDIR"> <Directory Id="dir2787390E4B7313EB8005DE08108EFEA4" Name="scheduler"> <Component Id="SchedulerComponent" Guid="{9254F7E1-DE41-4EE5-BC0F-BA668AF051CB}"> <File Id="fil9A013D0BFB837BAC71FED09C59C5501B" KeyPath="yes" Source="SourceDir\DTBookMonitor.exe" /> <File Id="fil4F0D8D05F53E6AFBDB498E7C75C2D98F" KeyPath="no" Source="SourceDir\DTBookMonitor.exe.config" /> <File Id="filF02F4686267D027CB416E044E8C8C2FA" KeyPath="no" Source="SourceDir\monitor.bat" /> <File Id="fil05B8FF38A3C85FE6C4A58CD6FDFCD2FB" KeyPath="no" Source="SourceDir\output.txt" /> <File Id="fil397F04E2527DCFDF7E8AC1DD92E48264" KeyPath="no" Source="SourceDir\pipelineOutput.txt" /> <File Id="fil83DFACFE7F661A9FF89AA17428474929" KeyPath="no" Source="SourceDir\process.bat" /> <File Id="fil2809039236E0072642C52C6A52AD6F2F" KeyPath="no" Source="SourceDir\README.txt" /> </Component> </Directory> </DirectoryRef> </Fragment> </Wix> I then run the following commands: candle -ext WixUtilExtension -ext WiXNetFxExtension DaisyFarmer.wxs Scheduler.wxs light -sice:ICE20 -ext WixUtilExtension -ext WiXNetFxExtension Scheduler.wixobj DaisyFarmer.wixobj -out DaisyFarmer.msi I'm getting an error when I run light.exe which says "DaisyFarmer.wxs(20) : error LGHT0094 : Unresolved reference to symbol 'Component:SchedulerComponent' in section 'Product:{BB7FBBE4-0A25-4CC7-A39C-AC916B665220}'." What am I missing?

    Read the article

  • WiX: Prevent 32-bit installer from running on 64-bit Windows

    - by Tom the Junglist
    Hi everyone, Due to user confusion, our app requires separate installers for 32-bit and 64-bit versions of Windows. While the 32-bit installer runs fine on win64, it has the potential to create support headaches and we would like to prevent this from happening. I want to prevent the 32-bit MSI installer from running on 64-bit Windows machines. To that end I have the following condition: <Condition Message="You are attempting to run the 32-bit installer on a 64-bit version of Windows."> <![CDATA[Msix64 AND (NOT Win64)]]> </Condition> With the Win64 defined like this: <?if $(var.Platform) = "x64"?> <?define PlatformString = "64-bit"?> <?define Win64 ?> <?else?> <?define PlatformString = "32-bit"?> <?endif?> Thing is, I can't get this check to work right. Either it fires all the time, or none of the time. The goal is to check presence of the run-time msix64 variable against the compile-time Win64 variable and throw an error if these don't line up, but the logic is not working how I intend it to. Has anyone come up with a better solution? Thanks! Tom

    Read the article

  • WiX - create a bootstrap that passes arguments to the msi

    - by Dror Helper
    I need to create a bootstrap for my WiX project I've tried using setupbld.exe but it will only allow me to create an executable that will show my UI or one that will behave as a silent installer but not both. I need to be able to run the resulting executable with argument that will tell it wether or not to show the UI during installation. I've found this post by John Robbins that explains how to re-build the setup.exe stub used in the creation of the bootstrap but I was hoping there is a simpler way to do what I need. Does anyone know of a way to create a bootstrap that I use to run either as a simple (with UI) install or as a silent install.

    Read the article

  • Populating a combobox on selectedindex change of another combobox

    - by Riju K K
    Hi, I have created a custom dialog UI, which contains two combobox with SQL server instance & on selection of one of SQLServer instance, another combobox has to be filled with name of Databases on that server instance. I am able to find filling combo with SQL server Instances I had written a similar CustomAction to fill the combobox with database names [CustomAction] public static ActionResult FillDatabases(Session xiSession) { xiSession.Log("Begin CustomAction"); xiSession.Log("Opening view"); View lView = xiSession.Database.OpenView("DELETE FROM ComboBox WHERE ComboBox.Property='DBNAME'"); lView.Execute(); lView = xiSession.Database.OpenView("SELECT * FROM ComboBox"); lView.Execute(); int Index = 1; //bool flag = false; try { Microsoft.SqlServer.Management.Smo.Server svr = new Microsoft.SqlServer.Management.Smo.Server(xiSession["DBSRVR"]); foreach (Microsoft.SqlServer.Management.Smo.Database db in svr.Databases ) { String dbName = db.Name; Record lRecord = xiSession.Database.CreateRecord(3); xiSession.Log("Setting record details"); lRecord.SetString(1, "DBNAME"); lRecord.SetInteger(2, Index); lRecord.SetString(3, db.Name); xiSession.Log("Adding record"); lView.Modify(ViewModifyMode.InsertTemporary, lRecord); ++Index; } } catch (Exception ex) { //logException(xiSession, ex); xiSession.Log(ex.Message ); } lView.Close(); xiSession.Log("Closing view"); lView.Close(); return ActionResult.Success; } I want to call these custom actions somewhat like shown below, <Binary Id="CustomActions.CA.dll" SourceFile="CustomActions.CA.dll" /> <CustomAction Id="FillServerInstances" BinaryKey="CustomActions.CA.dll" DllEntry="FillServerInstances" Execute="immediate" Return="check" /> <CustomAction Id="FillDatabases" BinaryKey="CustomActions.CA.dll" DllEntry="FillDatabases" Execute="immediate" Return="check" /> <InstallUISequence> <Custom Action="FillServerInstances" After="CostFinalize" /> <Custom Action="FillDatabases" After="FillServerInstances" /> </InstallUISequence> I need to show this Sqlserver selection custom dialog from another custom UI, in case user clicked on a pushbutton. Am I doing the right thing in the WiX code? Is there a better way in which combobox custom action fire only when user click on a pushbutton? "FillDatabases" custom action have to be fire whenever user select a new SQLServer instance. How do i do that? Thanks

    Read the article

  • WIX Merge Module : Trying to use $(var.Project.TargetFileName)

    - by Stephen Bailey
    I have created a simple Wix 3 Merge Module in VS 2005 ( .wxs ) <?xml version="1.0" encoding="UTF-8"?> <Wix xmlns="http://schemas.microsoft.com/wix/2006/wi"> <Module Id="TestMergeModule" Language="1033" Version="1.0.0.0"> <Package Id="ef2a568e-a8db-4213-a211-9261c26031aa" Manufacturer="Me" InstallerVersion="200" /> <Directory Id="TARGETDIR" Name="SourceDir"> <Directory Id="MergeRedirectFolder"> <Component Id="Test_ModuleComponent" Guid="{1081C5BC-106E-4b89-B14F-FFA71B0987E1}"> <File Id="Test" Name="$(var.Project.TargetFileName)" Source="$(var.Project.TargetPath)" DiskId="1" /> </Component> </Directory> </Directory> </Module> </Wix> And I have added the project "Project" as a reference to this Merge Module, however I continue to get this error Error 7 Undefined preprocessor variable '$(var.Project.TargetFileName)'. Any suggestions, I am sure I am just missing the obvious here.

    Read the article

  • How do I share a WiX fragment in two WiX projects?

    - by Randy Eppinger
    We have a WiX fragment in a file SomeDialog.wxs that prompts the user for some information. It's referenced in another fragment in InstallerUI.wxs file that controls the dialog order. Of course, Product.wxs is our main file. Works great. Now I have a second Visual Studio 2008 Wix 3.0 Project for the .MSI of another application and it needs to ask the user for the same information. I can't seem to figure out the best way to share the file so that changing the information requested will result in both .MSIs getting the new behavior. I honestly can't tell if a merge module, an .wsi (include) or a .wixlib is the right solution. I would have hoped to find a simple example of someone doing this but I have failed thus far. Edit: Based on Rob Mensching's wixlib blog entry, a wixlib may be the answer, but I am still searching for an example of how to do this.

    Read the article

  • WiX tricks and tips

    - by Si
    We've been using WiX 3 for a while now, and despite the usual gripes about ease of use, it's going reasonably well. What I'm looking for is useful advice regarding: Setting up a WiX project (layout, references, file patterns) Integrating WiX into solutions, and build/release processes Configuring installers for new installations and upgrades Also interested in any good WiX hacks you'd like to share, thanks!

    Read the article

  • Wix Burn issue: Uninstall fails saying "Found dependent"

    - by vivek chaurasiya
    I have made a burn bundle which encapsulates 2 msi (msi1 , msi2) . In the UI I use checkboxes to ask the user to select which MSI to install. Now if user selects one of the msi to install, installation goes fine. But during Uninstall action, the burn log file says : [][:15]: Detected package: Netfx4Full, state: Present, cached: None [][:15]: Detected package: DummyInstallationPackageId3, state: **Absent**, cached: None [][:15]: Detected package: msi2.msi, state: **Present**, cached: Complete [][:15]: Detect complete, result: 0x0 [][:16]: Plan 3 packages, action: Uninstall [][:16]: Will not uninstall package: msi2.msi, found dependents: 1 [][:16]: Found dependent: {08e74372-83f2-4594-833b-e924b418b360}, name: My Test Application In the install scenario, I chose to install msi2 and NOT msi1. My bundle code looks like: <Bundle Name="My Test Application" Version="1.0.0.0" Manufacturer="Bryan" UpgradeCode="CC2A383C-751A-43B8-90BF-A250F7BC2863"> <Chain> <PackageGroupRef Id='Netfx4Full' /> <MsiPackage Id="DummyInstallationPackageId3" SourceFile="msi1.msi" ForcePerMachine="yes" InstallCondition="var1 = 1" > </MsiPackage> <MsiPackage SourceFile="msi2.msi" Vital="yes" Cache="yes" Visible="no" ForcePerMachine="yes" InstallCondition="var2 = 2" > </MsiPackage> </Chain> My OnDetectPackageComplete() looks like: private void OnDetectPackageComplete(object sender, DetectPackageCompleteEventArgs e) { if (e.PackageId == "DummyInstallationPackageId3" ) { if (e.State == PackageState.Absent) InstallEnabled = true; else if (e.State == PackageState.Present) UninstallEnabled = true; } } What should I do so that the burn bundle is freely able to uninstall the msi which the user selected at the time of install. Besides, If I select both msi to install, then uninstall is working fine. IMO, there is some problem b/w the relation of bundle and the 2 msi. Please help me as I am stuck with this problem.

    Read the article

  • Anybody have any success getting around IIS7 issues with WiX 3.5?

    - by Will
    WiX 3.5 still is having issues with creating websites in IIS7. I can get around most of them, but I'm getting hosed by the inability to configure the website authentication mode. Traditionally, you would just use the WebDirProperties to, for instance, turn on windows authentication: <iis:WebDirProperties Id="OMFG3.5BUGSUX" WindowsAuthentication="yes" /> Well, this doesn't work. So, now, once my nice lovely installer exits you get a big fat screw-you-unauthorized-jerk message. Not exactly professional looking. Does anybody have any suggestions/tips on working around these shortcomings in WiX?

    Read the article

  • Wix create non advertised shortcut for all users / per machine

    - by mcdon
    In WIX, how do you create a non advertised shortcut in the allusers profile? So far I've only been able to accomplish this with advertised shortcuts. I prefer advertised shortcuts because you can go to the shortcut's properties and use "find target". In the tutorials I've seen use a registry value for the keypath of a shortcut. The problem is they use HKCU as the root. When HKCU is used, and another user uninstalls the program (since it's installed for all users) the registry key is left behind. When I use HKMU as the root I get an ICE57 error, but the key is removed when another user uninstalls the program. I seem to be pushed towards using HKCU though HKMU seems to behave correctly (per-user vs all-users). When I try to create the non advertised shortcut I get various ICE error such as ICE38, ICE43, or ICE 57. Most articles I've seen recommend "just ignore the ice errors". There must be a way to create the non advertised shortcuts, without creating ICE errors. Please post sample code for a working example.

    Read the article

  • WiX: Installing Service as LocalService

    - by Tom the Junglist
    Hey there, I am trying to get my application an installer via WiX 3.0. The exact code is: <File Id="ServiceComponentMain" Name="$(var.myProgramService.TargetFileName)" Source="$(var.myProgramService.TargetPath)" DiskId="1" Vital="yes"/> <!-- service will need to be installed under Local Service --> <ServiceInstall Id="MyProgramServiceInstaller" Type="ownProcess" Vital="yes" Name="MyProgramAddon" DisplayName="[removed]" Description="[removed]" Start="auto" Account="LocalService" ErrorControl="ignore" Interactive="no"/> <ServiceControl Id="StartDDService" Name="MyProgramServiceInstaller" Start="install" Wait="no" /> <ServiceControl Id="StopDDService" Name="MyProgramServiceInstaller" Stop="both" Wait="yes" Remove="uninstall" /> Thing is, for some reason LocalService fails on the "Installing services" step, and if I change it to "LocalSystem" then the installer times out while trying to start the service. The service starts fine manually and at system startup, and for all intents and purposes works great. I've heard there are issues getting services to work right under LocalService, but Google isnt really helping as everyone's responses have been "got it to work kthx". Just looking to get this service set up and started during installation, that's all. Any help? Thanks!

    Read the article

  • Installing Win32 shared SxS policy via WiX 3.0 MSM fails for 2nd app

    - by dr-stevep
    I am attempting to author a merge module for use by multiple application installers to install a Win32 Shared SxS Assembly and its associated Policy. I'm using WiX 3.0 to generate the MSM and test MSIs. So far it works fine for the first app installer that runs … but the second app installer fails because the Policy file already exists (HRESULT: 0x800700B7). What requirement(s) for correct Win32 Shared SxS Policy installation am I missing? I have submitted WiX bug 3005301 for this (https://sourceforge.net/tracker/?func=detail&atid=642714&aid=3005301&group_id=105970) and posted VS2008 projects that reproduce the problem. URL: ftp.digital-rapids.com/upload/SteveP/ User: drc-support Password: drc-support Link: ftp://drc-support:[email protected]/upload/SteveP/ wix-Bugs-3005201.rar contains a VS2008 solution that builds the MSM and MSIs that reproduce the issue. (~3MB) wix-Bugs-3005301_Output.rar contains the generated MSM, MSI, and wixpdb files (~40MB)

    Read the article

  • Wix CopyFile only on target machine

    - by Burt
    I need to be able to copy a file that exists on the target machines hard-drive based on a registry setting that holds the folder path. I have been trying to get this going for a day or two and am having difficulty, can anyone help? Thanks, B

    Read the article

  • WiX - create a bootstrap that passes arguments to the msiexec

    - by Dror Helper
    I need to create a bootstrap for my WiX project I've tried using setupbld.exe but it will only allow me to create an executable that will show my UI or one that will behave as a silent installer but not both. I need to be able to run the resulting executable with argument that will tell it wether or not to show the UI during installation. I've found this post by John Robbins that explains how to re-build the setup.exe stub used in the creation of the bootstrap but I was hoping there is a simpler way to do what I need. Does anyone know of a way to create a bootstrap that I use to run either as a simple (with UI) install or as a silent install.

    Read the article

  • Problem with WiX Votive 3.0 preprocessor

    - by Leith Bade
    I have just started using WiX for the first time. I added a WiX Votive project to my existing C project. To automatically select the correct source folder for the binaries add used the following: <Directory Id="INSTALLLOCATION" Name="Trapeze Capture For Objective" FileSource="$(var.CaptureForObjective.TargetDir)"> That results in the following error: 1C:\code\CaptureForObjective\Installer\Product.wxs(10,0): error CNDL0150: Undefined preprocessor variable '$(var.CaptureForObjective.TargetDir)'. The C project is called CaptureForObjective, and the WiX project is called Installer. What do I need to do to get this to work?

    Read the article

  • Retrieve COM ProgID from exe without registering it

    - by mangelo
    Background: I would like to extract the COM data from a VB6 application so I can register it correctly (according to Microsoft best practice) the application. I am using WiX 3.0 and heat.exe will not extract the data (known issue with heat) and I do not have ready access to the associated TLB file. The VB6 application does not have compatibility turned on so it regenerates the COM GUIDs every build (They want to have the application be able to run side by side with an older version.) I created a C# application that will collect the TypeLib, interface and CoClass information from the VB6 application without registering it and create a wxs file for candle to use. My company has several other older applications like this and I would like to make it a more generic solution. The Issues: 1.Is there a way to collect the 'true' ProgID (programmer intended one) from the application with out the project or TLB file and without registering it? 2.Is there a way to find out the intended Threading Model from a DLL without registering it? (I intend that it can handle all COM active items, might as well be complete) Thank you.

    Read the article

1 2 3  | Next Page >