Proliant RAID 1 Rebuild Questions

Posted by Nicholas on Server Fault See other posts from Server Fault or by Nicholas
Published on 2011-03-14T23:53:57Z Indexed on 2011/03/15 0:11 UTC
Read the original article Hit count: 677

Filed under:
|
|
|

I have a HP Proliant ML350 G5 server that experienced a power supply failure overnight. The power supply was replaced but unfortunately it got restarted with only 1 disk in the RAID 1 set plugged in. (The raid controller is the build in E200i).

The raid BIOS then said on start-up that it had entered Interim Recovery Mode. However I would have expected it to still start up with only the 1 drive. The bios however says that it cannot find a C: drive and enters a reboot loop polling the other boot devices. First question is, is this normal behaviour not to start up on 1 disk?

The second drive was then plugged in (all drives are ok) and the raid bios started an automatic rebuild on that disk. This appears to be a background process as there is no progress shown. However based on the light flashing it looks like it is working. My second question is how long will this rebuild take? (36GB 15K SAS drive).

I cannot see any error messages and it looks like it is rebuilding the drive ok, but the computer still will not start-up. It still says during the boot up process that the C: drive is not found. If I wait for the rebuild to finish, is it likely to fix itself and find the C: drive? Or is there some other problem here?

© Server Fault or respective owner

Related posts about server

Related posts about raid