  • Proliant Support Pack and Ubuntu on older HP Proliants

    - by snl
    We have a couple of oldish HP Proliant servers -- one DL385 G1 and one DL360 G5, to be exact -- that we'd like to upgrade from CentOS 5 to Ubuntu LucidLynx. The problem is that HP doesn't offer Ubuntu Proliant Support Packs for these particular models. Would you upgrade regardless, skipping the PSPs altogether? Are there alternative hardware monitoring tools that would match the functionality of the PSPs? Is there a hack to install the PSP RPMs on an Ubuntu system?

    Read the article

  • Installing Windows on HP Proliant Servers without SmartStart

    - by Fitzroy
    I have a PXE server for deploying Windows XP and Windows 7 to workstations. The process is as follows: Boot the workstation from the NIC. Workstation sends a DHCP request. DHCP server responds with an IP address and the location of the PXE server. Workstation downloads WinPE image file from PXE server via TFTP Workstation stores WinPE image file in memory and executes it. Once booted into WinPE, I connect to a network share to gain access to either the Windows XP or Windows 7 installation files. A custom script is launched to guide you through the process of formatting and partitioning the hard drive(s) (using DISKPART and FORMAT). Another custom script asks for details such as the hostname to assign to the workstation. The answers provided are used to build an unattended answer file (SIF [Setup Information File] for WinXP and XML for Win7). The Windows setup EXE is launched, passing the unattended answer file to it as a parameter. The Windows XP and Windows 7 installation sources have been customised to include the drivers for our Dell workstations. They also run a number of scripts upon first booting up to install software packages. This process works very well for our workstations and I would now like to use it for building our servers too. The vast majority of our servers are HP Proliant DL360 G6, DL380 G5 and DL380 G6. They’re running Windows Server 2003 (various editions) or 2008 (various editions). To date, we have always built the HP Proliant servers using the SmartStart CD provided. SmartStart does three useful things for us: Setup RAID with HP Array Configuration Utility (ACU). Installs and configures SNMP Installs various HP Tools for Windows (HP Array Configuration Utility, HP Array Diagnostic Utility, HP Proliant Integrated Management Log Viewer, etc) Using SmartStart I have never had to manually download and install Windows drivers for network, sound, video, etc. I'm not sure if this is because SmartStart copies drivers from the CD during setup, or whether Windows just has the drivers natively in its driver CAB. If I abandon the SmartStart CD in favour of my PXE server I would have to do the following: As I wont have access to ACU, I'll configure the RAID (before booting to the PXE server) by pressing F8 (during the boot process) to access Option ROM Configuration for Arrays (ORCA). Installation of SNMP and the HP Tools will have to be installed once the Windows installation is complete using the Proliant Support Pack. Is this method OK? Is there anything that the SmartStart CD does that I'll be unable to do by other means? Are there any disadvantages to not using the SmartStart CD? Many thanks. UPDATE 05/01/12 I’ve been reading through the SmartStart Scripting Toolkit documentation. The scripting toolkit contains command line tools which work within WinPE and can such things as configure BIOS settings, configure an array and setup ILO. I’m personally not too bothered about configuring BIOS settings as I rarely deviate from the defaults (unless the server is to be a Hyper-V host). I’m not too fussed about being able to configure the array from within WinPE, as I’m happy to just press F8 and use Option ROM Configuration for Arrays (ORCA). Although, if it’s easy enough to do, I will explore this further, as it saves time if everything can be configured from within WinPE. One of the nice features all the tools possess is that you can pass input files to them. EG. Configure one server to your requirements, capture its configuration to a file (using the appropriate tool), you can then use the tool on other servers passing the input file with the captured configuration. Array controller drivers appear to be included with the toolkit along with example of how to incorporate them within a WinPE build. I suppose WinPE won’t be able to see logical volumes (I.E 2x physical disks in a RAID 1 configuration) without the array controller drivers? I mentioned in my post that SmartStart normally installs a bunch of Windows HP tools for you. I’ve had a look today, and if you run the SmartStart CD from within Windows all the tools can be installed. Therefore I can do this after the Windows installation is complete. The SmartStart CD appears to contain a lot Windows drivers. I can customise my Windows 2008 source to incorporate these drivers. However, I understand that incorporating an array controller driver is a little different to most drivers. I believe that you have to provide the driver during the very early stages of the Windows setup. I’m working through the Scripting Toolkit documentation to try and work this out...

    Read the article

  • HP Proliant ML115 G5 - Boot order lost after reboot

    - by Filipe YaBa Polido
    I have one HP Proliant ML 115 G5 (AMD) with the latest BIOS (07-06-2009) and recently I've installed an USB disk. This is a common problem on old Proliant servers. When you plug the USB disk, BIOS boot order changes and tries to boot via USB. So, I'll change the BIOS settings and make the SATA disk the default boot device. The problem is, when I need to unplug the usb disk, and plug it again later. I can't be always changing the BIOS settings... How can one solve this for ever?!?!

    Read the article

  • Difficulty racking HP ProLiant Gen8 servers

    - by Systemspoet
    We're an all Proliant shop with around 50 servers, mostly DL360s and DL380, from G5's through G7's. We just got our first two G8's in and went to rack them. We were stunned to find out that the new cable management arms protrude almost 1 inch deeper into the rack then previous iterations of the Proliant line. Unfortunately that causes them to occupy the same space as the PDU's in our APC racks. In a non-densely populated section of rack that's no biggie, but in a densely populated section it's impossible to get the cable arm into place without dislodging another machine's power. Has anyone else run into this? Obviously racking machines without cable management arms is not an option. I supposed we could reconfigure our racks but that's a nightmare.

    Read the article

  • Difficulty racking Proliant G8's

    - by Systemspoet
    We're an all Proliant shop with around 50 servers, mostly DL360s and DL380, from G5's through G7's. We just got our first two G8's in and went to rack them. We were stunned to find out that the new cable management arms protrude almost 1 inch deeper into the rack then previous iterations of the Proliant line. Unfortunately that causes them to occupy the same space as the PDU's in our APC racks. In a non-densely populated section of rack that's no biggie, but in a densely populated section it's impossible to get the cable arm into place without dislodging another machine's power. Has anyone else run into this? Obviously racking machines without cable management arms is not an option. I supposed we could reconfigure our racks but that's a nightmare.

    Read the article

  • Ubuntu + Raid on HP proliant DL 160 G6

    - by Adam Matan
    Hi, I'm, trying to install Ubuntu 8.04 Server on an HP Proliant DL160 G6. The HP hardware is certified by Ubuntu for the 9.04 version, which I can't install due to company policy. The problem is that Ubuntu would not recognize the RAID 1+0 disk configured by the BIOS. The raid creates one ~470GB disk from two 500GB physical disks. Any ideas? Adam

    Read the article

  • No video output and no status light on HP Proliant Microserver

    - by tombull89
    I have an issue with a "N40L" HP Proliant Microserver. When the server is powered on the power light turns green but the machine's status light (the HP logo on the front) stays off and there is no video output through th onboard VGA. The system fan kicks in and if connected to a network the link light shows activity. I have no extra boards (iLO card, graphics card) only 4GB PNY non-standard stick of RAM.

    Read the article

  • Getting hp-snmp-agents on HP ProLiant DL360 on Lenny working

    - by mark
    After receiving our HP ProLiant DL360 I'd like to integrate the machine into our Munin system and thus enable ProLiant specific information to be exposed via SNMP. I'm running Debian Lenny with kernel 2.6.26-2-vserver-amd64 . I've followed http://downloads.linux.hp.com/SDR/getting_started.html and the HP repository has been added to /etc/apt/sources.list.d/HP-ProLiantSupportPack.list . Setting up Lenny SNMP itself is not a problem, I configure it to have a public v1 community string to read all data and it works. I install hp-snmp-agents and run hpsnmpconfig and it adds additional lines to the top of /etc/snmp/snmpd.conf : dlmod cmaX /usr/lib64/libcmaX64.so snmpd gets restarted. Via lsof I can see that libcmaX64 was loaded and is used by snmpd, put I do not get any additional information out of snmp. I use snmpwalk -v 1 -c public ... and I can see many OIDs but I do not see the new ones I'd expect, most notably temperatures, fan speed and such. The OIDs I'm expecting are e.g. 1.3.6.1.4.1.232.6.2.6.8.1.4.1 , this is from the existing munin plugins from http://exchange.munin-monitoring.org/plugins/snmp__hp_temp/version/1 . snmpd[19007]: cmaX: Parsing shared as a type was unsucessful snmpd[19007]: cmaX: listening for subagents on port 25375 snmpd[19007]: cmaX: subMIB 1 handler has disconnected snmpd[19007]: cmaX: subMIB 2 handler has disconnected snmpd[19007]: cmaX: subMIB 3 handler has disconnected snmpd[19007]: cmaX: subMIB 5 handler has disconnected snmpd[19007]: cmaX: subMIB 6 handler has disconnected snmpd[19007]: cmaX: subMIB 8 handler has disconnected snmpd[19007]: cmaX: subMIB 9 handler has disconnected snmpd[19007]: cmaX: sent ColdStarts on ports 25376 to 25393 snmpd[19007]: cmaX: subMIB 10 handler has disconnected snmpd[19007]: cmaX: subMIB 11 handler has disconnected snmpd[19007]: cmaX: subMIB 14 handler has disconnected snmpd[19007]: cmaX: subMIB 15 handler has disconnected snmpd[19007]: cmaX: subMIB 16 handler has disconnected snmpd[19007]: cmaX: subMIB 21 handler has disconnected snmpd[19007]: cmaX: subMIB 22 handler has disconnected snmpd[19007]: cmaX: subMIB 23 handler has disconnected snmpd[19007]: cmaX: subMIB 1 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 2 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 3 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 5 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 6 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 8 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 9 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 10 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 11 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 14 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 15 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 16 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 21 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 22 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 23 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 18 handler has disconnected snmpd[19007]: cmaX: subMIB 18 will be sent on port 25393 to cpqnicd snmpd[19007]: NET-SNMP version 5.4.1 This doesn't look particular bad for me, it's just informational I guess. I've compared the walking OID output with and without the module and there's no difference in the OID served back at all. Are there any other prerequisites I'm missing? I've also noticed that from the time I installed hp-snmp-agents it adds a lot of additional daemons and that my load suddenly jumps to 1. I've uninstalled the package for now. Is this expected behavior?

    Read the article

  • hp ProLiant DL380 G6 server error code: 347 of array controller

    - by alhaythum
    I have got a bran new hp ProLiant DL380 G6 server with embedded smart array P410i controller, I got 164 GB SATA drives and wanted to change them with 300 GB SATA drives before installation. Now, we replace the drives and begin the configuration with the hp DVD and begin; when we reach the point that we want to save the configurations, an error message appears: "The operation has failed with an unknown error, please restart the application and attempt the operation again" When using Rescan System, this error message appears: "Status Alerts - Smart Array P410i in Embedded Slot Warning Status Message Code Description 347 The cache for Smart Array P410i Embedded Slot is not configured" We return back to the 164 GB SATA drives and the message just keeps appearing again. Any help please.

    Read the article

  • Configuring RAID1 on HP Proliant Microserver N54L / Ubuntu 14.04.1 LTS [duplicate]

    - by Chris Beach
    This question already has an answer here: Cant find my harddrives in ubuntu installation? 2 answers I've bought a N54L and fitted two 3GB drives. Keen to get set up with RAID1. BIOS: SATA controller mode set to "RAID" RAID Option ROM utility: both physical drives set up as one logical drive When I came to install Ubuntu (14.04.1), both drives appeared during the setup process. I was only expecting to see the logical drive, although I'm a complete novice with RAID. I've read that the HP Proliant Microservers don't have "proper" RAID support, and require some kind of driver to be installed. I've tried a few HP utilities from the following apt repo: deb http://downloads.linux.hp.com/SDR/repo/mcp wheezy/current non-free On installation, most say "server not supported" Would appreciate your advice.

    Read the article

  • Proliant ML350 Won't Load Windows

    - by Mike
    I have a HP Proliant ML350 G4 running Windows 2003 Server Std Edition that will not load Windows on boot. It gave me a BSOD while running a recent Windows update and has not been able to boot since. The BSOD was a generic error, "Hardware Fault. Contact vendor." I am not getting any errors when the machine boots--it just hangs with a black screen when Windows starts to load. The machine will not boot into safe mode either--it gets stuck after beginning to load drivers. When trying to load the Windows recovery console I get the message that Windows cannot find any hard disks on the machine. This, despite having to load the driver for my storage controller. The HP Smart Start diagnostics finds no problems with my hard disks nor anything else. What should I try next? Mainly, I just want to be able to pull the data off my hard disks.

    Read the article

  • Getting USB boot to work in SmartOS on HP ProLiant N40L

    - by user126579
    I recently downloaded SmartOS and tried running it on my HP ProLiant N40L, but it always fails on boot. After dd'ing the image to the USB stick, I plug it into the internal USB header and turn the machine on. After selecting from GRUB, it displays the following: , bss=0x0 It sits there for 2-4 minutes, then finally boots the OS and displays the following: WARNING: Couldn't read ACPI SRAT table from BIOS. lgrp support will be limited to one group. SunOS Release 5.11 Version joyent_20120614T184600Z 64-bit Copyright (c) 2010-2012, Joyent Inc. All rights reserved. WARNING: kvm: no hardware support After that, it hangs. I've tried this with two different USB sticks. I've seen some mentions on the SmartOS website about people running it on an N40L, booting from USB, so maybe it's just broken hardware? Has anyone gotten this working?

    Read the article

  • Ubuntu Server on Proliant ML350 G4

    - by eduardoavdr
    Hi Everyone, I have been given the task to change OS of a HP Proliant ML350 G4 server, and I decided to use Ubuntu server edition for that matter. The thing is that the server has already installed Windows server 2000 on the only Hard drive it has (SCSI). My question is, could I install an IDE HD on the IDE connection it has and install ubuntu without overwritting the boot configuration, so if I wanted to go back to the windows 2000 server installation with no problems? It also has a tape drive which is used for backups. Do you guys know how buntu deals with such devices? Thanks for your time

    Read the article

  • HP ProLiant Smart Array "lock up" code 0x11

    - by ewwhite
    I've a ProLiant DL580 G7 server that experienced a storage subsystem failure during production. The system appeared available and responded to pings, but all I/O access stalled (the system load must have been 100+). The ASR did not trigger at the specified watchdog timeout. I had to force a reboot from the ILO. During POST, I received the following error: A controller failure event occurred prior to this power-up. (Previous lock up code = 0x11) I haven't pulled the ADU report yet, but I'm curious as to what this error actually means. I was not responsible for the the installation, but can see that the firmware is very old. But if there's anything else I should know about the error, I'd like to know for the post-mortem report. edit - I should add that the server had 95 days of uptime prior to the lock up.

    Read the article

  • Teamed network cards on a Proliant Server

    - by Matt
    We have 4 network cards in a Proliant server with Server 2008R2 running Exchange 2010, with 1 card set to a static IP address and the other 3 set to DHCP. I just need some clarification as I have not teamed network cards. Do all the network cards need to have a static IP when I set as a team. The connection that has the static IP is the IP that I need to use for the Server. Is it possible to set the teamed cards to the same static IP or do I have to change the static IP to another IP then use it for the teamed IP? I will be using HP Network Configuration Utility to set this up.

    Read the article

  • HP proliant dl360 g5 fails to reboot

    - by user1039384
    Some history of this also available here. As of my latest update on the forum linked above, now cold reboot as well as hard reset and following boot for my proliant dl360 g5 works as expected and successfully boot the system. However, soft-reboot results in internal health indicator turning RED on the front and long beeps every around 6seconds until I either cold reboot or press and hold the power button. A summary of system state when this happens: Internal Health led indicator: RED External Health led indicator: Green No led next to any component is red or amber No POST message neither on the video output nor on IML logs (verified both at the time issue occures and after cold reboot that boots the system successfully). Any thoughts please share. I hope we can knock this issue down together with your help!

    Read the article

  • HP Proliant DL360 G5 + MSA50 RAID Setup recommendations

    - by JohnRB
    I am running a HP Proliant DL360 2 x 3GHz Xeon 16GB Ram P400 integrated RAID card with 6 x 73GB SAS HDDs running Ubuntu Server 14.04 CLI only. I recently got my hands on a MSA50 SAS Enclosure (10 x SAS HDD bays w/ SAS in/out interface) and wondering what you guys recommended as far as an addon raid controller for one of the pciex slots. I have both slots free Full and Half sizes. Any suggestions are greatly appreciated, I am an I.T. Consultant but have not used these particular units before so I was hoping to hear from someone who has. Thanks!

    Read the article

  • Proliant RAID 1 Rebuild Questions

    - by Nicholas
    I have a HP Proliant ML350 G5 server that experienced a power supply failure overnight. The power supply was replaced but unfortunately it got restarted with only 1 disk in the RAID 1 set plugged in. (The raid controller is the build in E200i). The raid BIOS then said on start-up that it had entered Interim Recovery Mode. However I would have expected it to still start up with only the 1 drive. The bios however says that it cannot find a C: drive and enters a reboot loop polling the other boot devices. First question is, is this normal behaviour not to start up on 1 disk? The second drive was then plugged in (all drives are ok) and the raid bios started an automatic rebuild on that disk. This appears to be a background process as there is no progress shown. However based on the light flashing it looks like it is working. My second question is how long will this rebuild take? (36GB 15K SAS drive). I cannot see any error messages and it looks like it is rebuilding the drive ok, but the computer still will not start-up. It still says during the boot up process that the C: drive is not found. If I wait for the rebuild to finish, is it likely to fix itself and find the C: drive? Or is there some other problem here?

    Read the article

  • UPS with a HP Proliant server

    - by Groo
    We placed a EATON Ellipse Max 1500 (900W) as the UPS for our HP Proliant ML350 G6. Upon first power failure (actually we only moved the UPS' input plug to a different socket), server immediatelly turned off, and the Health LED turned red and started blinking. UPS was in operation for about a week before that, with battery fully charged to 100%. Since our server's hot-plug supply is 460W, we are pretty sure we haven't overloaded it, the server was completely idle at that time (no web or win apps running except Windows Server core services). Then we tried to do the same with a different, no-name older PC (Core 2 Duo, 2Gb RAM) with a generic power supply (not sure what the power is) and it continued working when we pulled the plug out. UPS load was less than 15% (measured in the provided Eaton utility). We measured the UPS' output voltage using a smart oscilloscope and the THD of the UPS output waveform turned out to be 40%. Did you have similar experiences? Could this be a faulty UPS? Or a faulty power supply? Or some HP sensors configured to trigger too strictly? I wouldn't like replacing this UPS with the same brand, to get same results. [Edit] I also tried to do this while the server is turned off. While the UPS is working on battery, server will not start - as soon as I press the power button, Health LED starts blinking red.

    Read the article

  • Formatting an HP ProLiant dl380 G4

    - by i.h4d35
    I have an old HP ProLiant dl380 G4 server whose hard disk needs to be formatted. Unfortunately, I cannot seem to do so. For one, it doesn't seem to be detecting any Hard Drives attached to the Server. The Hard Disks show up in the Ctrl+A option (SCSI Configuration Utility). Also, while inserting the SmartStart CD (7.01 or 7.04), it shows a message that no logical drives are found and there aren't any options to create one. Alternately I've tried slipstreaming the SCSI Driver into the OS but that doesn't seem to be helping. Also, I have a USB Floppy drive (for the SCSI driver) but that doesn't seem to be detected. Also, directly installing the OS (MS Server 2003 Standard Edition) obviously doesn't work (shows no hard disk found) Could anyone please advise as to what other needs to be done to format my server? Also please tell me what are the possible errors/mistakes which've been made so that I can learn from them. I went through some questions here on ServerFault and the HP guides here but they weren't of much help to a n00b like me. Thanks in Advance.

    Read the article

  • Ubuntu 12.04 - HP ProLiant DL380 G4 - Load Maxes Out / Unresponsive

    - by Brian S
    Trying to post this question on here. I've posted it on the Ubuntu forums as well with no replies. Recently I upgraded an HP ProLiant DL380 G4 server from Ubuntu 10.04 server to Ubuntu 12.04 server. Upon doing so, the server will not - at random times - get to a load of 400+ and then become completely non-responsive. I use an SNMP graphing program (cacti) and the load steadily increases by about 10 every five minutes until it gets over 400 and the graphing stops. The graphs may not be accurate, but the CPU load averages about 3% before this happens - and right when the load starts increasing, it jumps to about 25% for 15 minutes and dramatically dips down to less than 1% (about 0.3%) until the graphing stops. I'm not able to open a SSH tunnel to the server to do anything. I've checked the /var/log/syslog and all logging stops at that time as well - with nothing else in there. The odd thing is - the server still responds to DNS queries for the zones it is authoritative on during this time - and at normal speed. Just not sure what the next step would be in order to find out what is going on - and how this issue can be corrected. The server cannot stay with Ubuntu 10.04 Server and needs to stay upgraded.

    Read the article

  • Remote RIB iLO on Proliant via RIBCL

    - by Wudang
    I'm trying to automate a process for our Ops. The process requires that some windows servers running on blades are shut down, left down for a few hours, the restarted when some other processes complete. This is done by an op logging on to each blade's iLO web interface to stop and start. I've been trying to automate this with HP's cpqlocfg program with partial success. I can issue the GET_POWER, GET_USER_INFO, etc commands but SET_HOST_POWER fails in a specific way. Using the cpqlocfg GET_EVENTLOG command I can see the events XML login and the power comand being issued from the iLO interface but then nothing happens. Some hints from googling suggest ACPI isn't configured properly but I can't find any hits on how to verify this. Am I even using the right command? There's also a few other options like PRESS_PWR_BUTTON etc. Problem is I have nowhere to test this, all I can do at the moment is give a script to ops and ask them to try it as 4am on a Sunday when they try the proc. The shutdown is trivial as I can use the windows "shutdown" command, it's the power on that I need help on. Anyone done this? I'd tag this "rib ribcl ilo" but lack the rep points, sorry.

    Read the article

  • Red Hat 5.3 on HP Proliant DL380 G5 and failed drive on RAID controller

    - by thinkdreams
    I have a development ERP server here in my office that I assist with support on, and originally the DBA requested a single drive setup for some of the drives on the server. Thus the hardware RAID controller (an HP embedded controller) looks like: c0d0 (2 drive) RAID-1 c0d1 (2 drive) RAID-1 c0d2 (1 drive) No RAID <-- Failed c0d3 (1 drive) No RAID c0d4 (1 drive) No RAID c0d5 (1 drive) No RAID c0d2 has failed. I replaced the drive immediately with a spare using the hot-swap, but the c0d2 continues to mark itself as failed, even when I umount the partition. I'm loathe to reboot the server since I'm concerned about the server coming back up in rescue mode but I'm afraid that's the only way to get the system to re-read the drive. I assumed there was some sort of auto-detection routine for this, but I haven't been able to figure out the proper procedure. I have installed the HP ACU CLI utilties, so I can see the hardware RAID setup. I'd really like to find out what the proper procedure should have been, where I went wrong, and how to correct it now. Obviously this goes without saying I should NOT have listened to the DBA and set the drives up as RAID-1 throughout as was my first instinct. He wasn't worried about data loss, but it sure would have been easier to replace the failed drive. :)

    Read the article

  • Configuring HP Proliant iLO using hponcfg

    - by Abhay Kumar
    I am configuring an iLO using hponcfg by logging into the machine remotely and running hponcfg with scripts Mod_Directory.xml and then with Mod_Network.xml. I am enabling the DHCP on the device. But after the above scripts are executed successfully and upon rebooting the iLO, it shows the IP address to be 0.0.0.0. What is missing here, so that the iLO gets an IP from DHCP automatically after configuration?