Search Results

Search found 2609 results on 105 pages for 'dell perc'.

Page 1/105 | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • Upgrading a PERC h310 to a PERC H710 mini RAID controller on a Dell R620

    - by Gregg Leventhal
    I have an ESXi 5.0 Free license host using an internal Datastore (RAID 5, 5 Disk) that was configured with a Dell PERC h310 RAID controller. The disk performance was very poor, so I upgraded to the PERC H710 Mini. The IT Tech installed the controller and powered the host back on. I had to rescan the controller and the datastore appeared. Should any settings be changed in the RAID BIOS, or should the default settings be sufficient? Is they anything to be aware of when performing this type of upgrade in order to achieve the maximum performance?

    Read the article

  • JBOD with PERC H810

    - by primero
    I'm wondering if anybody has ever used Dell storage products like the MD3220 array in a JBOD configuration. From what I can tell only perc h810 will work for external JBOD but that is not terribly specific, and for some reason I couldn't find many examples on the web of people configuring dell storage products as JBOD. My question is: Is it possible to connect to am MD3220 array, or other Dell arrays using a PERC h810 controller and use it as JBOD, and if so do I have to configure every disk in the array as a RAID 0 volume?

    Read the article

  • Getting access to physical drives in ESXi v5.5 installation on Dell PowerEdge R710 with PERC 6/i

    - by Big-Blue
    I've acquired a Dell PowerEdge R710 server a few days ago, which includes a PERC 6/i RAID controller. The server is now fitted with a SATA SSD, one SAS drive and four SATA HDD's, all of which I would like to be passed through to ESXi in an "as-is" state, without creating any logical drives in the RAID controller. Now, the ESXi v5.5 installation image I grabbed from the Dell homepage starts just fine but only lists the logical drives and connected flash drives as possible installation targets, not any of the physical drives. If I create a small logical drive on my SSD (which the PERC 6/i detects as SATA-SSD type), the ESXi install wizard lists the SSD value on that drive as false; which is far from optimal. I have also tried disabling the RAID controller entirely in the setup, but that also did not help. Everything that should enable passthrough is enabled in BIOS, but that shouldn't be a concern at this early stage of the ESXi installation. How would I be able to install ESXi v5.5 to a part of my SSD that is connected to the storage controller, while giving it entire physical access to the disk (to allow for SMART values to be read etc.)?

    Read the article

  • Dell Inspiron 14z laptop vs Dell inspiron 14z ultrabook

    - by Jaspreet
    Just wanted to know if both of these are fully compatible with Ubuntu? If only specific versions of Ubuntu are compatible, then which ones? http://www.dell.com/ca/p/inspiron-14z-5423/pd http://www.dell.com/ca/p/inspiron-n411z/pd Matters I am more concerned about are: 1) Affect on battery life for both? 2) Dual boot without the need to re-install Windows (don't want to use pirated copy) on a separate partition? I can definitely re-partition using partition Magic/EaseUS. 3) Also, I would not prefer keeping my OS's on SSD (in case of 14z ultra-book) It would be a great help, as I am considering to buy one of these with prime reason of Ubuntu.

    Read the article

  • Resize NTFS System Partition on Perc 6/i RAID

    - by Cipher42
    I've inherited a Dell server that is running out of space on C:. I'd like to quickly and painlessly resize the C drive with partitioning software. However, the RAID card is causing me some troubles. I've resized plenty of desktops in my time, but never a server with hardware RAID. Can anyone recommend software that is GUARANTEED to work with the Dell PERC 6/i? Hopefully someone has resized the system partition with this RAID card before! :) Of course, proper backups are available but I'd be more comfortable with a tried and true solution to save the headache of the restore.... Thanks in advance!

    Read the article

  • PERC H710 mini raid controller advanced settings (BIOS)

    - by gregg
    I upgraded from a PERC h310 to an H710 controller on my Dell R620 but didnt get any increase in performance. This is a ESXi host with a 5 disk RAID 5. I noticed when going to the RAID BIOS that the advanced settings section was not activated/checked off. In that section is the strip element size: 64kb (default) read policy: no read ahead and the write policy: write-through. Will checking that section do any harm to the existing raid array or will it simply enable those policies and hopefully boost performance? Or, lastly, is it already using those policies and the checkmark is simply to activate them for changes

    Read the article

  • Very slow disk performance on Dell PowerEdge 2950 w/ PERC 6/i running RAID 10

    - by vocoder
    I recently set up a server running Ubuntu 10.04 LTS on a Dell PowerEdge 2950 server - it has 6 500 gb 7200RPM SATA drives setup in a RAID 10 config. I am seeing extremely poor disk performance - the RAID array reports all disks are normal and using MegaCLI, it looks like the BBU is fine. hdparm -tT /dev/sda reports: Timing cached reads: 90 MB in 2.05 seconds = 43.96 MB/sec Timing buffered disk reads: 24 MB in 3.11 seconds = 7.72 MB/sec So as you can see, it takes forever to something as simple as an apt-get upgrade and even logging into the server. How do I go about troubleshooting what is causing this? I upgraded the firmware on the PERC 6i RAID controller to the latest, but didn't see any improvements.

    Read the article

  • Microphone on a Dell Vostro 3360

    - by Pilb
    After upgrading my vostro 3360 on Ubuntu 12.04, I saw that drivers were not available for this version (notably for network). So I decided to install 11.10 but the mic still doesn't work (notably on Skype, Gtalk etc.) I join the model of the audio device and the drivers which were installed before I upgraded to ubuntu 12.04 (I succeeded only in installing the network one) Can you help me to find the solution to this problem with my microphone? Thanks , Pilb. Message in French : Bonjour, Après que je me sois rendu compte d'une anomalie dans la gestion du micro (sous Gtalk), j'ai essayé différentes solutions sans succès (1 2 et 3) Mon ordinateur dell vostro 3360 m'a été livré sous ubuntu 11.10, j'ai voulu le mettre sous 12.04 mais les drivers n'étaient pas compatibles. Je suis donc revenu sur Oneiric mais sans les drivers installés par Dell en usine. néanmoins, j'ai pris soin de noter leurs références (sans toutefois savoir si le micro fonctionne avec ces pilotes, mais cela me semble possible). Pourriez-vous me dire s'il est possible d'installer ces pilotes ? Ou alors si vous avez une solution concernant ce problème de micro ? Modèle de la carte son : Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) Alsa-hda-cirrus-oneiric driver in DKMS format (notamment) Dell-laptop-oneiric friver in DKMS format ethernet-alx oneiric driver in DKMS format Je vous remercie d'avance de votre aide et vous souhaite une bonne journée ! Pilb.

    Read the article

  • Dell R510 vs R710

    - by AX1
    Hello, the Dell R510 and R710 can both hold regular configurations (e.g. X5650, 24 GB RAM, etc.) and these usually come out to about the same price. Is there a particular reason why one would choose the R510 over the R710 or vice versa? There really appears a lack of differentiating factors. The only 'major' factor I found, which doesn't apply to me though, is that the R510 can hold up to 12 3.5in HDDs while the R710 (which is slightly more expensive) can only hold up to 6 3.5in HDDs. Maybe you guys have some input and bought either of these machines (or both) to shed some light on other differences and why someone should choose one over the other as the pricing is pretty much the same with my configuration. Thanks!

    Read the article

  • Dell Optiplex 980 vs. Dell Studio XPS 9000?

    - by Dave
    My company is allowing me to upgrade to either the XPS 9000 or the Optiplex 980. I haven't bought an Optiplex in over a decade, and the only thing I can remember is that the Optiplex is really meant for corporate IT environments, and we're not even close being large enough to have IT issues. I think the components might be of higher quality as well, like the motherboard and power supply. The XPS 9000 is about $150 cheaper than the Optiplex, but the Optiplex has 4GB more RAM, a 2nd video card, and an extra year of service. Seems like the Optiplex is a better deal overall, but since I haven't ever used one, I wanted to see what everyone else here thought.

    Read the article

  • Wifi disabled on dell Inspiron Mini 10 (1018)

    - by Manu
    My netbook cannot access the wifi network, and I cannot enable it. This is the second time this has happenned. The first time, it came back after a lot of restarts and BIOS factory resets. Ubuntu sometimes simply won't connect to any wifi networks, and other times it will say that the wireless is blocked by a hardware switch. I have tried pressing F2 and doing a BIOS reset, with no luck. sudo rfkill list all gives : 0: phy0: Wireless LAN Soft blocked: no Hard blocked: yes 1: dell-wifi: Wireless LAN Soft blocked: yes Hard blocked: yes

    Read the article

  • WiFi and Bluetooth will not work on Dell Studio XPS 1645

    - by Ross
    Today I acquired a Dell XPS 1645. Ubuntu seems to run alright on it however The bluetooth is not detected and the WiFi doesn't work. The WiFi is especially weird because I actually have the restricted driver enabled for it. It also worked for a short while when I first booted into Ubuntu however now there isn't even an option to enable wireless. If anyone could possibly help me out with this I'd deeply appreciate it. I've not had to return to Windows for a good while and it's not something I want to have to do now.

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • How to fix the Dell Mini 10v (1010) touchpad with Ubuntu 12.04.1

    - by John Lawrence Aspden
    I've just installed 12.04.1 from scratch on my Mini 10v, and the touchpad is behaving a bit oddly. It's got buttons integrated into the touchpad, and it looks as though a touch on a button is also being registered as a touch on the touchpad, causing all sorts of problems with clicking and dragging. Is there a fix for this? I seem to remember on very old versions of ubuntu having to disable the lower part of the touchpad, but I don't think it's been an issue for some time.

    Read the article

  • Dell VRTX - slow cluster shared storage

    - by NorbyTheGeek
    I have a brand new Dell VRTX box set up as a Failover Cluster running HA Hyper-V virtual machines. This is my first time setting up clustering, and my first time with one of these boxes, so I'm sure I've missed something. The virtual machines are experiencing high disk latency and bad performance when accessing their VHD(x) files located on a Cluster Shared Volume. The VRTX has 10 x 900 GB 10K SAS drives in RAID 6 configuration, and the VRTX has the redundant Shared PERC 8 controllers. Both blades have full access to the virtual disks. There are two M520 blades installed, each with 128 GB RAM. MPIO is configured for the PERC 8 controllers. Operating system on the blades is Server 2012 (NOT R2). The RAID 6 array is split into a small (8 GB) volume for cluster quorum witness and a large (6.5 TB) volume for a Cluster Shared Volume (mounted on the nodes as C:\ClusterStorage\Volume1) An example of slow disk access: logging into a Server 2012 VM and having Server Manager come up automatically. Disk access goes to 100%, with write speeds at 20 MB or so, read speeds of 500 KB or so, and Average Response Time of over 1000 ms, sometimes spiking at 4000-5000 ms or so. It's the latency that really worries me. Is there something specific I should look at in my configuration? It doesn't seem to matter whether I use VHD or VHDX, dynamic or static.

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • Install MegaCli to Monitor Perc 5/i in Nexentastor 3

    - by Peter Valadez
    I have a Dell 2950 with a Perc 5/i Raid controller that we've already installed Nexentastor 3 Community Edition on. We setup a raid-10 array that and put a ZFS pool on top of the hardware. As I understand, in this configuration ZFS/Nexentastor will not be able to tell when a disk fails in the array. Obviously, this is not optimal. Since the Dell Perc 5/i controller is a rebranded LSI controller, you should be able to use the MegaCli utility to manage the array and monitor its condition. I had seen in a separate forum that the Perc 5/i is very similar to the LSI MegaRAID 8480E, so I tried installing the MegaCli utility at the link below. However, I have not been able to successfully install the utility. http://www.lsi.com/support/products/Pages/MegaRAIDSAS8480E.aspx Here is what happened when I tried to install MegaCli: root@Nexenta2:/files# pkgadd -d MegaCli.pkg Warning: unable to relocate '$BASEDIR' mv: cannot move `solmegacli-8.02.16/' to a subdirectory of itself, `solmegacli-8.02.16//var/lib/dpkg/alien/solmegacli/reloc/solmegacli-8.02.16' mv: cannot move `solmegacli-8.02.16/' to a subdirectory of itself, `solmegacli-8.02.16//opt/solmegacli-8.02.16' 822-date: warning: This program is deprecated. Please use 'date -R' instead. 822-date: warning: This program is deprecated. Please use 'date -R' instead. solmegacli_8.02.16-1_all.deb generated (Reading database ... 41397 files and directories currently installed.) Preparing to replace solmegacli 8.02.16-1 (using solmegacli_8.02.16-1_all.deb) ... Unpacking replacement solmegacli ... Setting up solmegacli (8.02.16-1) ... In /var/logs/dpkg.log: 2012-03-23 20:40:19 status unpacked solmegacli 8.02.16-1 2012-03-23 20:40:19 configure solmegacli 8.02.16-1 8.02.16-1 2012-03-23 20:40:19 status unpacked solmegacli 8.02.16-1 2012-03-23 20:40:19 status half-configured solmegacli 8.02.16-1 2012-03-23 20:40:19 status installed solmegacli 8.02.16-1 So... I've got three questions: Is it possible to install and use MegaCli in Nexentastor 3? If so, how can I install MegaCli on Nexentastor 3? Suggestions welcome!!! If not, is there a better way to monitor the condition of the Perc 5/i hardware raid? Our 2950 does have a DRAC card, so can I use that to monitor the raid condition?

    Read the article

  • iDRAC on Dell R710 and R720

    - by BT643
    I've called Dell twice to try and clarify this basic (or so I thought) question, but I've had two different answers so far. We have a Dell R710, and a Dell R720. Does DRAC come installed by default on either? Dell said it comes build into the motherboard on the R720 but the second time I rang, they said we didn't have it. Can anyone tell me if DRAC comes as standard on the R720? I'm aware we'll need a license as well, I'm just interested in the physical capability on the server. I've never used DRAC before and know next to nothing about it, so apologies if this seems blindingly simple. Thanks

    Read the article

  • Is it possible to install Windows Server 2012 on a Dell PowerEdge with PERC S100 card?

    - by Warren P
    According to Dell's own website, the Windows Server 2012 media driver "inbox" does not contain drivers for the Perc S100 controller that is in a Dell PowerEdge T110 II server we'd like to evaluate with Server 2012. I have found drivers only for Server 2008 R2, which is what the server is currently running. Is it possible to upgrade this server? (Booting up the Server 2012 DVD image leads to the expected result that it can not locate the system's hard drives or its hard drive controller card, as the drivers for the PERC S100 are not on the installation DVD image.)

    Read the article

  • Dell Vostro 1000 w/fresh XP Pro installation running very slow

    - by ssvarc
    I'm working on a Dell Vostro 1000 laptop. It was running slowly and hanging, antivirus scans turned up nothing and the same with the Dell diagnostics (DFT hung - but Dell's diagnostics gave the HD a pass) so I imaged the HD and installed XP Pro on it. The laptop is still slow! (It takes a noticeable delay to enter words into the Google search box in IE and the computer hangs every time it enters the XP screensaver.) What are the likely possibilities at this point and how would I go about checking for them?

    Read the article

  • Dell XPS 15z/ L511Z merging partitions

    - by Alvin M
    i have a situation here, i bought a new dell xps 15z and was successful in making drive partitions through the help of this site (http://superuser.com/questions/313082/dell-xps-15-l502x-hard-drive-partition) now i have drive C with 100.55gb and a new volume with 578.45gb im planning to use EaseUS again to undo this and resize my drive C but im scared i might cause damage to my drive, is there a proper way to undo this and transfer the remaining 78.45gb from the new volume back to my drive C again? please help

    Read the article

1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >