  • Looking to trade a 1U HP Proliant DL360 G5 in exchange for a small linux VPS

    - by user597875
    I have a 1U HP Proliant DL360 G5 that I have no place to rack and would like to trade it for a small linux VPS. If interested let me know... Here are the specs of the server: Model: Intel Xeon CPU 5150 @ 2.66GHz, 4MB L2 Cache Processor Speed: 2.7GHz Processor Sockets: 2 Processor Cores per Socket: 2 Logical Processors: 4 8GB of memory 4x72GB 10k SAS drives Manufacturer: HP Model: Proliant DL360 G5 BIOS Version: P58

    Read the article

  • Recommend a basic 3D graphics card for HP ProLiant DL360 G5?

    - by arathorn
    We've got an HP ProLiant DL360 G5 running Windows Server 2008 R2 that needs a graphics card with 3D acceleration (the integrated ATI ES1000 graphics don't have this). This is an unfortunate requirement that we can't avoid, as it is required by S/W installed on the server that is beyond our control. Looks like the PCI-Express slots in the box are x8 (1 full and 1 low profile). We just need a basic card, as long as it has the 3D acceleration. Any recommendations?

    Read the article

  • Uncorrectable Machine Check Exception on HP DL360 G7

    - by ReDSerpenT
    i have about every hour in IML (hplog) from HP DL360 G7 record: CRITICAL: CPU - Uncorrectable Machine Check Exception (Board 0, Processor 1, APIC ID 0x00000003, Bank 0x00000005, Status 0xBE000000'00800400, Address 0x00003FFF'811239E0, Misc 0x00000000'00007FFF) hpasmcli show server System : ProLiant DL360 G7 ROM version : P68 09/30/2010 iLo present : Yes Can someone tell me what part is being referenced by the IML status codes above? Thank in advance!

    Read the article

  • HP DL360 G4 screen resolution problem

    - by dogmatic69
    I just bought an old blade server to mess about with at home and cant get the thing to work. I have run the installer 11.10 x64 server and that was fine. After installing and rebooting, POST is fine but when grub kicks in the screen shows a popup type box complaining that it cant use the resolution. I have tried different screens and its always the same. I can reboot and go back into the installer and the screen is fine. I tried to follow some guides on-line about changing the resolution but I cant get a terminal. I found one in the installer but that is using the ram as /. the installer says 'the drive is mounted as "/target"' but I don't see that, nor /mnt/target. Could anyone help me configure this and get it running. Thanks.

    Read the article

  • HP DL360 G6 NC328i Dual Port Gigabit - Windows Server 2003 R2 Driver Problem

    - by brianjd
    I recently installed Windows Server 2003 R2 (64) on a DL360 G6 without using the SmartStart CD (it didn't like the MSDN media). But when I attempted to install the network drivers post-install using the packages from the HP website, I wasn't successful. Though I selected the correct package, the installer reported I did not have the necessary hardware configuration. Has anyone had a similar experience? Thanks

    Read the article

  • HP proliant dl360 g5 fails to reboot

    - by user1039384
    Some history of this also available here. As of my latest update on the forum linked above, now cold reboot as well as hard reset and following boot for my proliant dl360 g5 works as expected and successfully boot the system. However, soft-reboot results in internal health indicator turning RED on the front and long beeps every around 6seconds until I either cold reboot or press and hold the power button. A summary of system state when this happens: Internal Health led indicator: RED External Health led indicator: Green No led next to any component is red or amber No POST message neither on the video output nor on IML logs (verified both at the time issue occures and after cold reboot that boots the system successfully). Any thoughts please share. I hope we can knock this issue down together with your help!

    Read the article

  • HP Proliant DL360 G5 + MSA50 RAID Setup recommendations

    - by JohnRB
    I am running a HP Proliant DL360 2 x 3GHz Xeon 16GB Ram P400 integrated RAID card with 6 x 73GB SAS HDDs running Ubuntu Server 14.04 CLI only. I recently got my hands on a MSA50 SAS Enclosure (10 x SAS HDD bays w/ SAS in/out interface) and wondering what you guys recommended as far as an addon raid controller for one of the pciex slots. I have both slots free Full and Half sizes. Any suggestions are greatly appreciated, I am an I.T. Consultant but have not used these particular units before so I was hoping to hear from someone who has. Thanks!

    Read the article

  • Bad disk performance on HP DL360 with Smarty Array P400i RAID controller

    - by sarge
    I have a HP DL360 server with 4x 146GB SAS disks and a Smart Array P400i RAID controller with 256MB cache. The disks are in RAID 5 (3 disks + 1 hot spare). The server is running VMware ESX 3i. The disk write performance is really bad. Here are some numbers: ns1:~# hdparm -tT /dev/sda /dev/sda: Timing cached reads: 3364 MB in 2.00 seconds = 1685.69 MB/sec Timing buffered disk reads: 18 MB in 3.79 seconds = 4.75 MB/sec ns1:~# time sh -c "dd if=/dev/zero of=ddfile bs=8k count=125000 && sync" 125000+0 records in 125000+0 records out 1024000000 bytes (1.0 GB) copied, 282.307 s, 3.6 MB/s real 4m52.003s user 0m2.160s sys 3m10.796s Compared to another server those number are terrible: Dell R200, 2x 500GB SATA disks, PERC raid controller (disks are mirrored). web4:~# hdparm -tT /dev/sda /dev/sda: Timing cached reads: 6584 MB in 2.00 seconds = 3297.79 MB/sec Timing buffered disk reads: 316 MB in 3.02 seconds = 104.79 MB/sec web4:~# time sh -c "dd if=/dev/zero of=ddfile bs=8k count=125000 && sync" 125000+0 records in 125000+0 records out 1024000000 bytes (1.0 GB) copied, 35.2919 s, 29.0 MB/s real 0m36.570s user 0m0.476s sys 0m32.298s The server isn't very loaded and the VMware Infrastructure Client performance monitor is showing 550KBps average read and 1208KBps average write for the last 30 minutes (highest write rate: 6.6MBps). This has been a problem from the start. Any ideas?

    Read the article

  • hp proliant dl360 disk diagnostic issue

    - by user1039384
    We recently got two used drives (15000) and installed on our HP proliant dl360 G5 server. Created RAID1 and used HP SmartStart CD to perform diagnostics. Interestingly, the Diagnostic tab immidiately fails on Logical drive testing saying the Disk1 should be replaced, while the Test tab successfully runs all the complete tests on both disks and does not find any issue. At the meantime, when booting to esxi 5, vSphere periodically shows the Disk1 as Unknown and Logical drive in recovery process. This happens every 5-10 minutes. Here is the log from HP SmartScan diagnostic: 1 - Device, Test: Logical Drive 1, Storage Controller in Slot 0 1 - Description: The controller has reported a critical error in the drive error log. 1 - Recommended Repair: This drive should be replaced. 1 - Failed Count: 44 1 - Error code: F157 There is also another error log record (see below): 2 - Device, Test: test_components/libstorage.so ID 2 - Description: An unexpected exception occurred while performing an operation. Exception message: CISS_StatusHandler::evaluate: commandStatus = 4 (INVALID); hexdump of CISS_ErrorInfo: 00000000: __ __ 04 __ 20 __ __ __ __ __ __ __ __ __ __ __ .... ... ........ 00000010: __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ ........ ........ 00000020: __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ ........ ........ Device: Hard Drive 2, Storage Controller in Slot 0 Property name: Bad Target Count 2 - Recommended Repair: Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics. 2 - Failed Count: 48 2 - Error Code: F62 Note that rebooting didn't help and I was running the latest diagnostic software version. Anyone has a clue? Is this a real disk issue? BTW, the controller is Smart Array E200i Thanks in advance

    Read the article

  • Getting hp-snmp-agents on HP ProLiant DL360 on Lenny working

    - by mark
    After receiving our HP ProLiant DL360 I'd like to integrate the machine into our Munin system and thus enable ProLiant specific information to be exposed via SNMP. I'm running Debian Lenny with kernel 2.6.26-2-vserver-amd64 . I've followed http://downloads.linux.hp.com/SDR/getting_started.html and the HP repository has been added to /etc/apt/sources.list.d/HP-ProLiantSupportPack.list . Setting up Lenny SNMP itself is not a problem, I configure it to have a public v1 community string to read all data and it works. I install hp-snmp-agents and run hpsnmpconfig and it adds additional lines to the top of /etc/snmp/snmpd.conf : dlmod cmaX /usr/lib64/libcmaX64.so snmpd gets restarted. Via lsof I can see that libcmaX64 was loaded and is used by snmpd, put I do not get any additional information out of snmp. I use snmpwalk -v 1 -c public ... and I can see many OIDs but I do not see the new ones I'd expect, most notably temperatures, fan speed and such. The OIDs I'm expecting are e.g. 1.3.6.1.4.1.232.6.2.6.8.1.4.1 , this is from the existing munin plugins from http://exchange.munin-monitoring.org/plugins/snmp__hp_temp/version/1 . snmpd[19007]: cmaX: Parsing shared as a type was unsucessful snmpd[19007]: cmaX: listening for subagents on port 25375 snmpd[19007]: cmaX: subMIB 1 handler has disconnected snmpd[19007]: cmaX: subMIB 2 handler has disconnected snmpd[19007]: cmaX: subMIB 3 handler has disconnected snmpd[19007]: cmaX: subMIB 5 handler has disconnected snmpd[19007]: cmaX: subMIB 6 handler has disconnected snmpd[19007]: cmaX: subMIB 8 handler has disconnected snmpd[19007]: cmaX: subMIB 9 handler has disconnected snmpd[19007]: cmaX: sent ColdStarts on ports 25376 to 25393 snmpd[19007]: cmaX: subMIB 10 handler has disconnected snmpd[19007]: cmaX: subMIB 11 handler has disconnected snmpd[19007]: cmaX: subMIB 14 handler has disconnected snmpd[19007]: cmaX: subMIB 15 handler has disconnected snmpd[19007]: cmaX: subMIB 16 handler has disconnected snmpd[19007]: cmaX: subMIB 21 handler has disconnected snmpd[19007]: cmaX: subMIB 22 handler has disconnected snmpd[19007]: cmaX: subMIB 23 handler has disconnected snmpd[19007]: cmaX: subMIB 1 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 2 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 3 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 5 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 6 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 8 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 9 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 10 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 11 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 14 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 15 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 16 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 21 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 22 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 23 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 18 handler has disconnected snmpd[19007]: cmaX: subMIB 18 will be sent on port 25393 to cpqnicd snmpd[19007]: NET-SNMP version 5.4.1 This doesn't look particular bad for me, it's just informational I guess. I've compared the walking OID output with and without the module and there's no difference in the OID served back at all. Are there any other prerequisites I'm missing? I've also noticed that from the time I installed hp-snmp-agents it adds a lot of additional daemons and that my load suddenly jumps to 1. I've uninstalled the package for now. Is this expected behavior?

    Read the article

  • HP DL160 vs DL360 for virtualization

    - by Chris
    Hi, We're planning to consolidate our infrastructure (a dozen servers). We'll buy two or three identical new servers who will be setup as a XenServer pool. Load balancing and HA tools will monitor the pool and vMotion VMs in case of failure/overload. I know that the DL100 series of HP servers is cheaper than the DL300 serie (in every sense of the word). As we don't need local storage (we have a SAN) and can live with a temporary down server (provided that Xen Server HA tools work as advertized), what are the downsides going with the DL100 serie ? Thanks, Chris

    Read the article

  • WDS updating raid drivers in an already existing image WIM

    - by Tim
    Here is my current setup. WDS installed on Server 2008 R2 for the new driverstore and multicast features. A Windows Server 2003 32bit Standard image built to support previous DL360 models. A new HP DL360 G6 which has a new raid controller in it. I need to add the driver for the raid controller into my Server 2003 32bit standard install image but I can't seem to figure out the correct method to do so. So far I've tried the following: Mounting the image and placing the drivers into the Sysprep drivers folder, adding the PCI device codes into the sysprep.inf file and committing the changes to the image. Pushing the image to a DL360 G4, ensuring the driver is in the correct locations and re-sysprepping the image. Hoping that the new driverstore feature would magically work with 2003 (a guy can dream cant he?) Is there some standard method that I can use to update this image with the new drivers or do I need to start from scratch with an entirely new build? Thanks in advance.

    Read the article

  • Parallel Data Warehouse

    - by jchang
    The Microsoft Parallel Data Warehouse diagram was somewhat difficult to understand in terms of the functionality of each subsystem in relation to the configuration of its components. So now that HP has provided a detailed list of the PDW components , the diagram below shows the PDW subsystems with component configuration (InfiniBand, FC, and network connections not shown). Observe that there are three different ProLiant server models, the DL360 G7, DL370 G6 and the DL380 G7, in five different configurations...(read more)

    Read the article

  • Small Business HP Virtualisation and iSCSI SAN Options

    - by Robin Day
    We are a small business that hosts our core product on a number of HP servers. Our core production setup is 1x HP DL380, high powered for a SQL Server Database 1x HP DL360, mid powered for our core application server 6x HP DL320, low powered for our front ends We run our training / testing / support systems on a similar setup, the servers are just older and less powerful. Unfortunately this is now causing us issues as the system has grown beyond the capabilities of these older servers. Upgrading these servers would be expensive and we believe that virtualisation is probably the way to go for the future. Locally we run a number of test / dev environments on ESXi using Direct Storoage on a couple of high powered DL360's and these are performing fairly well. We're thinking that instead of replacing all of our test servers that we can implement an iSCSI SAN and one or two high powered hosts. Hopefully looking that when it comes to replace our live servers as well that we can just expand the virual environment to cope. So my question is... Can anyone offer any advice on some suitable options? We have generally always been extremely happy with HP servers, all of our kit is currently HP, therefore our preference would be to stick with HP, however, I'm always happy to hear about other options. I'm hoping that initially a budget of around 15-25k (GBP) would be suitable, this could potentially be increased if I had confidence that the system would pave the way for a cost effective upgrade of our live systems in the future as well. I am new to SAN's and my only real experience is playing with OpenFiler on some old desktops. I think iSCSI should be suitable, but I've not done any research into how SQL server may perform. I've had a browser through HP's sites and see plenty of information about EVA, MSA, LeftHand, etc. However, from looking at all that, I don't see which options would be best and more importantly I don't know exactly what I would need to buy. Any help, links, opinions would be much appreciated. Thanks

    Read the article

  • Proliant Support Pack and Ubuntu on older HP Proliants

    - by snl
    We have a couple of oldish HP Proliant servers -- one DL385 G1 and one DL360 G5, to be exact -- that we'd like to upgrade from CentOS 5 to Ubuntu LucidLynx. The problem is that HP doesn't offer Ubuntu Proliant Support Packs for these particular models. Would you upgrade regardless, skipping the PSPs altogether? Are there alternative hardware monitoring tools that would match the functionality of the PSPs? Is there a hack to install the PSP RPMs on an Ubuntu system?

    Read the article

  • Software to measure power draw of HP Server

    - by tombull89
    I'm after some software to measure the power draw of a HP Server, namely a DL360 series. I know Nagios is used for logging and monitering but I'm not sure if it logs power usage as well. I've also tried to find the HP Server Management package but am not sure if this shows power usage either. I'm thinking my best bet would to buy some sort of device that goes inbetween the wall and the servers plug. Can anybody suggest what would do for me?

    Read the article

  • HP Smart Array p400i with Intel X25-M 160 SSD

    - by user67304
    I have a pair of x25-M 160 Intel SSD's in an HP DL360 G5 with a p400i Smart Array running 512 BBWC. The disk performance I am getting on this box and another identical one does not come close to matching the same two drives running through a cheap 3ware RAID card. Any idea? I have played with the cache settings, but nothing allows me to get the same results. It seems like the Smart Array controller is the bottleneck.

    Read the article

  • HP Smart Array p400i with Intel X25-M 160 SSD

    - by user67304
    I have a pair of x25-M 160 Intel SSD's in an HP DL360 G5 with a p400i Smart Array running 512 BBWC. The disk performance I am getting on this box and another identical one does not come close to matching the same two drives running through a cheap 3ware RAID card. Any idea? I have played with the cache settings, but nothing allows me to get the same results. It seems like the Smart Array controller is the bottleneck.

    Read the article

  • How HP D2700 disk enclosure is monitored for alarms via SNMP

    - by VSAC
    We have HP D2700 disk enclosure and we would like to monitor D2700 (connected to HP Proliant DL360G8) for alarms.I have following questions regarding this. What are the options available for reporting D2700 hardware alarms (disk failure, power failure) via SNMP? We understand the D2700 to have an Ethernet interface for controller A and B and alarms are available via SNMP via this interface. Can anyone provide the actual alarms via this interface? (MIB and alarm list) As we have a number of D2700’s and would like to minimize the number of physical connections to the switch and associated IP addresses; Is there a mechanism to monitor the D2700 from the SCSI connected HPDL360 and raise SNMP alarms from the DL360 for hardware failures on the D2700? If so can anyone provide details and the actual alarms and MIB via this mechanism? Thanks!

    Read the article

  • NIC Teaming HP Server running Win2003

    - by Colm
    Hello everyone. I'm new to server NIC TEaming. I have a HP ProLiant DL360 G4p running Win2003 with 2 NICs , only one is currently active. I'd like to activate the 2nd NIC connected (in a active/passive state) to a 2nd switch with only one IP address and ideally only one mac layer address. The 1st switch is a Cisco 2960G and the 2nd is a Cisco C3560G. There are VLANS, RSTP and PAGP in use already. Can someone give me an idea, in broad terms , of what technology/protocols I should be investigating (HSRP, SLB/TLB Teaming etc.) ? I can provide more info if needed. Thanks, Colm.

    Read the article

  • Clone remote CentOS server to local test server?

    - by dannymcc
    We have a dedicated server running ContOS 5.5. The server runs our Magento store and a basic php website with mysql. I have a spare rack server in my office (HP ProLiant DL360 G4) that has more than enough storage space to store a duplicate of our dedicated server. I would like to clone the dedicated server entirely and have a local duplicate. It wouldn't need to be kept in sync because I can do that with GIT. The reason I want to do this is simple; learn more about the dedicated server and CentOS. Is this possible? I have SSH access to the dedicated server and obviously complete access to the local server.

    Read the article

  • Dual Home HP Server running Win2003

    - by Colm
    Hello everyone. I'm new to server dual homing. I have a HP ProLiant DL360 G4p running Win2003 with 2 NICs , only one is currently active. I'd like to activate the 2nd NIC connected (in a active/passive state) to a 2nd switch with only one IP address and ideally only one mac layer address. The 1st switch is a Cisco 2960G and the 2nd is a Cisco C3560G. There are VLANS, RSTP and PAGP in use already. Can someone give me an idea, in broad terms , of what technology/protocols I should be investigating (HSRP, SLB Teaming etc.) ? I can provide more info if needed. Thanks, Colm.

    Read the article

  • VMWare - persistent "Host memory status" alarm in vSphere

    - by ewwhite
    I have a particular VMWare ESX 4.1 host that has a very persistent "Host memory status" alarm. This is running on an HP ProLiant DL360 G7 server. The HP ILO and System Management agents don't know any errors. If I clear the alarm in the vSphere client, it returns within a day. I've tried reseating DIMMs, however, the error does not indicate a problem with a specific module. There's another host in the cluster with an identical configuration. It's not exhibiting any issues. Any thoughts? This is touched on briefly on other forums (and here) with no clear resolution.

    Read the article