Search Results

Search found 14 results on 1 pages for 'h700'.

Page 1/1 | 1 

  • Dell R910 with Integrated PERC H700 Adapter

    - by Alex
    I am in the process of designing an architecture based around a single Dell R910 server running Windows Server 2008 Enterprise. I would like the server to have 8 RAID1 pairs of spinning disks, so I intend to implement: Dell R910 Server Integrated PERC H700 Adapter with 1 SAS expander on each SAS connector (so 8 expanders in total) 7 RAID1 pairs of 143Gb 15K HDD, each paired on one connector using an expander 1 RAID1 pair of 600Gb 10K HDD, paired on the remaining connector using an expander My main concern is not to introduce bottlenecks in this architecture, and I have the following questions. Will the PERC H700 Adapter act as a bottleneck for disk access? Will using SAS expanders for each RAID1 pair cause a bottleneck or would this be as fast as pairing disks directly attached to the SAS connectors? Can I mix the disks, as long as the disks in each RAID1 pair are the same? I assume so. Can anyone recommend any single-to-double SAS Expanders that are known to function well with the H700? Cheers Alex

    Read the article

  • Bad Blocks Exist in Virtual Device PERC H700 Integrated

    - by neoX
    I have a DELL server with PERC H700 Integrated controller. I've made RAID5 with 12 harddrives and the virtual device is in Optimal state, but I receive such errors under linux: sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bc e0 00 00 01 00 00 00 end_request: I/O error, dev sda, sector 30640487648 But all disk are in Firmware state: Online, Spun Up. Also there is not a single ATA read or write error in any disk in the raid (I check them with smartctl -a -d sat+megaraid,N -H /dev/sda). The only strange thing is in the output in megacli: megacli -LDInfo -L0 -a0 ... Bad Blocks Exist: Yes How could there be bad blocks in a Virtual Drive, which is in optimal state and no disk is broken or even with a single error? I tried "Consistency Check", but it finished successfully and the errors are still in dmesg. Could Someone help me to figure it out what is wrong with my raid?

    Read the article

  • What does Embedded SATA Controller : ATA mean?

    - by paulH
    I have a Poweredge R510 server with a PERC H700 Integrated RAID controller that is exhibiting slower than expected disk speeds (RAID 1 and RAID 10 arrays) and I'm looking at the configuration of the server. Running the command omreport chassis biossetup on the server shows me the following configuration setting: Embedded SATA Controller : ATA I can also see that the possible options for this setting are: off | ata | qdma | raid I've been looking online to find out what this setting means and what the various options refer to but I've been unable to find anything particularly helpful, so I was hoping that somebody here could help to enlighten me. Thanks, Paul.

    Read the article

  • Quantifying the effects of partition mis-alignment

    - by Matt
    I'm experiencing some significant performance issues on an NFS server. I've been reading up a bit on partition alignment, and I think I have my partitions mis-aligned. I can't find anything that tells me how to actually quantify the effects of mis-aligned partitions. Some of the general information I found suggests the performance penalty can be quite high (upwards of 60%) and others say it's negligible. What I want to do is determine if partition alignment is a factor in this server's performance problems or not; and if so, to what degree? So I'll put my info out here, and hopefully the community can confirm if my partitions are indeed mis-aligned, and if so, help me put a number to what the performance cost is. Server is a Dell R510 with dual E5620 CPUs and 8 GB RAM. There are eight 15k 2.5” 600 GB drives (Seagate ST3600057SS) configured in hardware RAID-6 with a single hot spare. RAID controller is a Dell PERC H700 w/512MB cache (Linux sees this as a LSI MegaSAS 9260). OS is CentOS 5.6, home directory partition is ext3, with options “rw,data=journal,usrquota”. I have the HW RAID configured to present two virtual disks to the OS: /dev/sda for the OS (boot, root and swap partitions), and /dev/sdb for a big NFS share: [root@lnxutil1 ~]# parted -s /dev/sda unit s print Model: DELL PERC H700 (scsi) Disk /dev/sda: 134217599s Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 1 63s 465884s 465822s primary ext2 boot 2 465885s 134207009s 133741125s primary lvm [root@lnxutil1 ~]# parted -s /dev/sdb unit s print Model: DELL PERC H700 (scsi) Disk /dev/sdb: 5720768639s Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 34s 5720768606s 5720768573s lvm Edit 1 Using the cfq IO scheduler (default for CentOS 5.6): # cat /sys/block/sd{a,b}/queue/scheduler noop anticipatory deadline [cfq] noop anticipatory deadline [cfq] Chunk size is the same as strip size, right? If so, then 64kB: # /opt/MegaCli -LDInfo -Lall -aALL -NoLog Adapter #0 Number of Virtual Disks: 2 Virtual Disk: 0 (target id: 0) Name:os RAID Level: Primary-6, Secondary-0, RAID Level Qualifier-3 Size:65535MB State: Optimal Stripe Size: 64kB Number Of Drives:7 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Number of Spans: 1 Span: 0 - Number of PDs: 7 ... physical disk info removed for brevity ... Virtual Disk: 1 (target id: 1) Name:share RAID Level: Primary-6, Secondary-0, RAID Level Qualifier-3 Size:2793344MB State: Optimal Stripe Size: 64kB Number Of Drives:7 Span Depth:1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Number of Spans: 1 Span: 0 - Number of PDs: 7 If it's not obvious, virtual disk 0 corresponds to /dev/sda, for the OS; virtual disk 1 is /dev/sdb (the exported home directory tree).

    Read the article

  • How to use 3T SAS HDDs which aren't supported by Dell PERC 6i

    - by Sunry
    We bought several 3T SAS hard disks want to use with our Dell R710 server. But we found our R710 can't recognize the 3T hd, and then we dig out the raid card is PERC 6i which doesn't support it. Contacted with Dell that H700 and H800 support 3T hd, thought we can buy a H700 , but the SAS cable is not available in the market right now. And it seems very hard for us to change the raid card, also no suitable tools to tease the special screws. So I want to know if any other method to use these 3T hds instead of putting them in the warehouse? Can I low formatting it to 2TB, and plug it into Dell R710 to use? Or a SAS to USB adapter to use it as USB external disk? I just want to use them by Dell R710 even external.

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • What would be the optimal disk config for SQL Server 2008 R2?

    - by Kev
    We have a new Dell R710 server that came with the following storage configuration: 8 x 146GB SAS 10k 6Gbps disks 1 x Perc H700 Integrated Controller (2 x 4 disks - 2 ports each supporting 4 disks) What would be the optimal configuration if we were just after performance? What would be the optimal configuration if we were after performance but wanted data resilience. As per 2 above but with a hot standby disk? We plan to run Windows 2008 R2 and SQL Server 2008 R2. Maximising storage capacity isn't a prime concern.

    Read the article

  • Windows-Server-2003 setup on Dell-PowerEdge R310 is hanging [closed]

    - by Robert Rose
    Possible Duplicate: Problems installing OS on Dell PowerEdge R410 I am trying to configure a Dell PowerEdge R310 server with Windows Server 2003. I've already configured the two hard drives as RAID1. The HD controller is PERC H700 Integrated and Adapter. Trying to stay with Windows Server 2003 on this fairly new server to save on cost and keep the configuration the same as my old server, which has been running like a champ for five years. Problem: During the OS installation, after everything has been copied from the installation CD, the installation hangs at a window labeled 'Windows Setup' with the message 'Setup is starting Windows' at the bottom. I'm wondering if this is a driver problem and if so, where can I get the drivers for the R310 or where can I get the media for the latest version of Windows Server 2003 which may include the necessary drivers? Will certainly appreciate some help here.

    Read the article

  • Best SQL Server Configuration with this hardware.

    - by DavidStein
    I just received my new SQL Server from Dell. The server will be serve approximately 15 OLTP databases which average 10GB in size. Here are the basic specs: Dell PowerEdge R510 with up to 12 Hot Swap HDDs,LED Intel Xeon E5649 2.53GHz, 12M Cache, 5.86 GT/s QPI, 6 core (Quantity of 2) 48GB Memory (6x8GB), 1333MHz Dual Ranked RDIMMs for 2 Processors, Optimized PERC H700 Integrated RAID Controller, 1GB NV Cache 300GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 4) 600GB 15K RPM SA SCSI 6Gbps 3.5in Hotplug Hard Drive (Quantity of 6) My first thought was to use 3 arrays. OS - Raid 1 - (2)300GB T-Log - Raid 1 (2)300GB DB - Raid 5 (5) 600GB Backup - (1) 600GB - non-raided. However, I could also do the following after purchasing one more drive for backup. OS and T-Log - Raid 10 - (4)300GB DB - Raid 10 (6)600GB The hard drive space is not an issue as the databases are not that large. I'm just trying to optimize the speed of the applications using these databases. So, what would you guys recommend?

    Read the article

  • dd oflag=direct 5x fast

    - by César
    I have Centos 6.2 in server with this specs: 2xCPU 16 Core AMD Opteron 6282 SE 64GB RAM Raid controller H700 1GB cache NV - 2HD 74GB SAS 15Krpm RAID1 stripe 16k (OS Centos 6.2) sda - 4HD 146GB SAS 15Krpm RAID10 stripe 16k (ext4 bs 4096, no barriers) sdb -> /vol01 Raid controller H800 1GB cache nv - MD1200 12HD 300GB SAS 15Krpm RAID10 stripe 256k (For DB Postgres 8.3.18) (ext4 bs 4096, stride 64, stripe-width 384, no barriers) sdc -> /vol02 I'm benchmarking IO speed with dd, and view thah if in RAID10 12 disk exec: dd if=/dev/zero of=DD bs=8M count=10000 oflag=direct 10000+0 records in 10000+0 records out 83886080000 bytes (84 GB) copied, 126,03 s, 666 MB/s but if I remove "oflag=direct" option obtain about 80 MB/s. In read benchmark, results are similar: dd of=/dev/null if=DD bs=8M count=10000 iflag=direct 10000+0 records in 10000+0 records out 83886080000 bytes (84 GB) copied, 79,5918 s, 1,1 GB/s If remove iflag=direct obtain 150MB/s... I don't understand this huge differences, on other machines y don't have this behavior. Can I have some kernel parameter misconfigured? Thanks!

    Read the article

  • RAID 10 or RAID 5 for multiple VMs - what is the best choice?

    - by Lars Fastrup
    I have just ordered a new rig for my business. We do a lot of software development for Microsoft SharePoint and need the rig to run several virtual machines for development and test purposes. We will be using the free VMware ESXi for virtualization. For a start, we plan to build and start the following VMs - all with Windows Server 2008 R2 x64: Active Directory server MS SQL Server 2008 R2 Automated Build Server SharePoint 2010 Server for hosting our public Web site and our internal Intranet for a few people. The load on this server is going to be quite insignificant. 2xSharePoint 2007 development server 2xSharePoint 2010 development server Beyond that we will need to build several SharePoint farms for testing purposes. These VMs will only be started when needed. The specs of the new rig is: Dell R610 rack server 2xIntel XEON E5620 48GB RAM 6x146GB SAS drives Dell H700 RAID controller We believe the new server is going to make our VMs perform a lot better than our existing setup (2xIntel XEON, 16GB RAM, 2x500 GB SATA in RAID 1). But we are not sure about the RAID level for the new rig. Should we go for having the the 6x146GB SAS drives in a RAID 10 configuration or a RAID 5 configuration? RAID 10 seems to offer better write performance and lower risk of a RAID failure. But it comes at a cost of less drive space. Do we need RAID 10 or would RAID 5 also be a good choice for us?

    Read the article

  • Disk performance below expectations

    - by paulH
    this is a follow-up to a previous question that I asked (Two servers with inconsistent disk speed). I have a PowerEdge R510 server with a PERC H700 integrated RAID controller (call this Server B) that was built using eight disks with 3Gb/s bandwidth that I was comparing with an almost identical server (call this Server A) that was built using four disks with 6Gb/s bandwidth. Server A had much better I/O rates than Server B. Once I discovered the difference with the disks, I had Server A rebuilt with faster 6Gbps disks. Unfortunately this resulted in no increase in the performance of the disks. Expecting that there must be some other configuration difference between the servers, we took the 6Gbps disks out of Server A and put them in Server B. This also resulted in no increase in the performance of the disks. We now have two identical servers built, with the exception that one is built with six 6Gbps disks and the other with eight 3Gbps disks, and the I/O rates of the disks is pretty much identical. This suggests that there is some bottleneck other than the disks, but I cannot understand how Server B originally had better I/O that has subsequently been 'lost'. Comparative I/O information below, as measured by SQLIO. The same parameters were used for each test. It's not the actual numbers that are significant but rather the variations between systems. In each case D: is a 2 disk RAID 1 volume, and E: is a 4 disk RAID 10 volume (apart from the original Server A, where E: was a 2 disk RAID 0 volume). Server A (original setup with 6Gpbs disks) D: Read (MB/s) 63 MB/s D: Write (MB/s) 170 MB/s E: Read (MB/s) 68 MB/s E: Write (MB/s) 320 MB/s Server B (original setup with 3Gpbs disks) D: Read (MB/s) 52 MB/s D: Write (MB/s) 88 MB/s E: Read (MB/s) 112 MB/s E: Write (MB/s) 130 MB/s Server A (new setup with 3Gpbs disks) D: Read (MB/s) 55 MB/s D: Write (MB/s) 85 MB/s E: Read (MB/s) 67 MB/s E: Write (MB/s) 180 MB/s Server B (new setup with 6Gpbs disks) D: Read (MB/s) 61 MB/s D: Write (MB/s) 95 MB/s E: Read (MB/s) 69 MB/s E: Write (MB/s) 180 MB/s Can anybody suggest any ideas what is going on here? The drives in use are as follows: Dell Seagate F617N ST3300657SS 300GB 15K RPM SAS Dell Hitachi HUS156030VLS600 300GB 3.5 inch 15000rpm 6GB SAS Hitachi Hus153030vls300 300GB Server SAS Dell ST3146855SS Seagate 3.5 inch 146GB 15K SAS

    Read the article

  • Determining cause of high NFS/IO utilization without iotop

    - by Matt
    I have a server that is doing an NFSv4 export for user's home directories. There are roughly 25 users (mostly developers/analysts) and about 40 servers mounting the home directory export. Performance is miserable, with users often seeing multi-second lags for simple commands (like ls, or writing a small text file). Sometimes the home directory mount completely hangs for minutes, with users getting "permission denied" errors. The hardware is a Dell R510 with dual E5620 CPUs and 8 GB RAM. There are eight 15k 2.5” 600 GB drives (Seagate ST3600057SS) configured in hardware RAID-6 with a single hot spare. RAID controller is a Dell PERC H700 w/512MB cache (Linux sees this as a LSI MegaSAS 9260). OS is CentOS 5.6, home directory partition is ext3, with options “rw,data=journal,usrquota”. I have the HW RAID configured to present two virtual disks to the OS: /dev/sda for the OS (boot, root and swap partitions), and /dev/sdb for the home directories. What I find curious, and suspicious, is that the sda device often has very high utilization, even though it only contains the OS. I would expect this virtual drive to be idle almost all the time. The system is not swapping, according to "free" and "vmstat". Why would there be major load on this device? Here is a 30-second snapshot from iostat: Time: 09:37:28 AM Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz avgqu-sz await svctm %util sda 0.00 44.09 0.03 107.76 0.13 607.40 11.27 0.89 8.27 7.27 78.35 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 44.09 0.03 107.76 0.13 607.40 11.27 0.89 8.27 7.27 78.35 sdb 0.00 2616.53 0.67 157.88 2.80 11098.83 140.04 8.57 54.08 4.21 66.68 sdb1 0.00 2616.53 0.67 157.88 2.80 11098.83 140.04 8.57 54.08 4.21 66.68 dm-0 0.00 0.00 0.03 151.82 0.13 607.26 8.00 1.25 8.23 5.16 78.35 dm-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-2 0.00 0.00 0.67 2774.84 2.80 11099.37 8.00 474.30 170.89 0.24 66.84 dm-3 0.00 0.00 0.67 2774.84 2.80 11099.37 8.00 474.30 170.89 0.24 66.84 Looks like iotop is the ideal tool to use to sniff out these kinds of issues. But I'm on CentOS 5.6, which doesn't have a new enough kernel to support that program. I looked at Determining which process is causing heavy disk I/O?, and besides iotop, one of the suggestions said to do a "echo 1 /proc/sys/vm/block_dump". I did that (after directing kernel messages to tempfs). In about 13 minutes I had about 700k reads or writes, roughly half from kjournald and the other half from nfsd: # egrep " kernel: .*(READ|WRITE)" messages | wc -l 768439 # egrep " kernel: kjournald.*(READ|WRITE)" messages | wc -l 403615 # egrep " kernel: nfsd.*(READ|WRITE)" messages | wc -l 314028 For what it's worth, for the last hour, utilization has constantly been over 90% for the home directory drive. My 30-second iostat keeps showing output like this: Time: 09:36:30 PM Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz avgqu-sz await svctm %util sda 0.00 6.46 0.20 11.33 0.80 71.71 12.58 0.24 20.53 14.37 16.56 sda1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sda2 0.00 6.46 0.20 11.33 0.80 71.71 12.58 0.24 20.53 14.37 16.56 sdb 137.29 7.00 549.92 3.80 22817.19 43.19 82.57 3.02 5.45 1.74 96.32 sdb1 137.29 7.00 549.92 3.80 22817.19 43.19 82.57 3.02 5.45 1.74 96.32 dm-0 0.00 0.00 0.20 17.76 0.80 71.04 8.00 0.38 21.21 9.22 16.57 dm-1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 dm-2 0.00 0.00 687.47 10.80 22817.19 43.19 65.48 4.62 6.61 1.43 99.81 dm-3 0.00 0.00 687.47 10.80 22817.19 43.19 65.48 4.62 6.61 1.43 99.82

    Read the article

  • RAID1 rebuild fails due to disk errors

    - by overlord_tm
    Quick info: Dell R410 with 2x500GB drives in RAID1 on H700 Adapter Recently one of drives in RAID1 array on server failed, lets call it Drive 0. RAID controller marked it as fault and put it offline. I replaced faulty disk with new one (same series and manufacturer, just bigger) and configured new disk as hot spare. Rebuild from Drive1 started immediately and after 1.5 hour I got message that Drive 1 failed. Server was unresponsive (kernel panic) and required reboot. Given that half hour before this error rebuild was at about 40%, I estimated that new drive is not in sync yet and tried to reboot just with Drive 1. RAID controller complained a bit about missing RAID arrays, but it found foreign RAID array on Drive 1 and I imported it. Server booted and it runs (from degraded RAID). Here is SMART data for disks. Drive 0 (the one that failed first) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1 3 Spin_Up_Time POS--K 142 142 021 - 3866 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10432 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 112 106 000 - 31 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 198 000 - 3 And Drive 1 (the drive which was reported healthy from controller until rebuild was attempted) ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 35 3 Spin_Up_Time POS--K 143 143 021 - 3841 4 Start_Stop_Count -O--CK 100 100 000 - 12 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 086 086 000 - 10455 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 11 192 Power-Off_Retract_Count -O--CK 200 200 000 - 10 193 Load_Cycle_Count -O--CK 200 200 000 - 1 194 Temperature_Celsius -O---K 114 105 000 - 29 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 3 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 In extended error logs from SMART I found: Drive 0 has only one error Error 1 [0] occurred at disk power-on lifetime: 10282 hours (428 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 18 00 00 00 6a 24 20 40 00 Error: IDNF at LBA = 0x006a2420 = 6956064 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 60 00 f8 00 00 00 6a 24 20 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 18 00 60 00 00 00 6a 24 00 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 80 00 58 00 00 00 6a 23 80 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 68 00 50 00 00 00 6a 23 18 40 00 17d+20:25:18.105 WRITE FPDMA QUEUED 61 00 10 00 10 00 00 00 6a 23 00 40 00 17d+20:25:18.104 WRITE FPDMA QUEUED But Drive 1 has 883 errors. I see only few last ones and all errors I can see look like this: Error 883 [18] occurred at disk power-on lifetime: 10454 hours (435 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 01 -- 51 00 80 00 00 39 97 19 c2 40 00 Error: AMNF at LBA = 0x399719c2 = 966203842 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:57.802 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:57.779 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:55.704 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 00 1d+00:25:55.681 READ LOG EXT 60 00 80 00 00 00 00 39 97 19 80 40 00 1d+00:25:53.606 READ FPDMA QUEUED Given those errors, is there any way I can rebuild RAID back, or should I make backup, shutdown server, replace disks with new ones and restore it? What about if I dd faulty disk to new one from linux running on USB/CD? Also, if anyone have more experiences, what could be causes for those errors? Crappy controller or disks? Disks are about 1 year old, but it is pretty unbelievable to me that both would die within so short timespan.

    Read the article

1