Search Results

Search found 41 results on 2 pages for 'ipmi'.

Page 1/2 | 1 2  | Next Page >

  • IPMI not fucntioning with Network Bonding

    - by muhammed sameer
    Hey, I am having problems with running IPMI on my servers that have network bonding enabled. Platform: CentOS release 5.3 (Final) Kernel: 2.6.18-92.el5 64bit Dell PowerEdge 1950 Ethernet controller: Broadcom Corporation NetXtreme II BCM5708 Gigabit Ethernet I have bonded the interface eth0 and eth1 as active passive, with eth0 as the active interface, below is conf description from /proc Bonding Mode: fault-tolerance (active-backup) Primary Slave: eth0 Currently Active Slave: eth0 MII Status: up MII Polling Interval (ms): 30 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth0 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:22:19:56:b9:cd Slave Interface: eth1 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:22:19:56:b9:cf My IPMI device is as follows IPMI Device Information Interface Type: KCS (Keyboard Control Style) Specification Version: 2.0 I2C Slave Address: 0x10 NV Storage Device: Not Present Base Address: 0x0000000000000CA8 (I/O) Register Spacing: 32-bit Boundaries I Have used openIPMI as well as freeipmi both to control the chassis via the IPMI card, but on servers which have bonding enabled, the command times out, below is the full run of the command with debug info. ipmi_lan_send_cmd:opened=[0], open=[4482848] IPMI LAN host 70.87.28.115 port 623 Sending IPMI/RMCP presence ping packet ipmi_lan_send_cmd:opened=[1], open=[4482848] No response from remote controller Get Auth Capabilities command failed ipmi_lan_send_cmd:opened=[1], open=[4482848] No response from remote controller Get Auth Capabilities command failed Error: Unable to establish LAN session Failed to open LAN interface Unable to get Chassis Power Status On the other hand I configured IPMI on a box with the same specs as mentioned above without bonding and IPMI works perfectly. Has anyone faced this problem with IPMI + Bonding ? I would be thankful is someone helps circumvent this issue. Muhammed Sameer

    Read the article

  • SuperMicro IPMI through OpenBSD PF Firewall

    - by thelsdj
    I'm trying to access a SuperMicro IPMI card that is behind an OpenBSD bridged firewall. A couple pieces of information: The OpenBSD firewall itself has a SuperMicro IPMI that I can access across the internet. The IPMI I'm trying to reach can be reached from behind the firewall. My gateway does arp request the IPMI and it does appear to respond (this is from the external interface of the firewall) 16:57:45.548892 arp who-has ipminame tell gwname 16:57:45.549500 arp reply ipminame is-at ipmimac But when I make a request to the IPMI IP from outside the firewall the external interface of the firewall shows no traffic with the IPMI ip as its destination. Any idea what might be causing this problem? Is there something about IPMI traffic that my gateway wouldn't like (the gateway is provided by my colocation provider so I can't easily debug it).

    Read the article

  • ESXI 4 IPMI 2.0 - Cannot connect to IPMI after boot past bios

    - by adamflavell
    Dear All, I would appreciate any help here. I have a Supermicro 6016T-NTRF running ESXI 4 fine. The health monitors are showing up so ESXI is picking up the IPMI status. But I cannot connect to the host remotely via the dedicated IPMI nic. When the machine is in bios section I CAN connect but as soon as ESXI starts to boot I get blocked. Supermicro say the issue must be that ESXI is blocking the IPMI ports. How can this be corrected? I have read that there is no firewall on ESXI 4. Thanks, Adam

    Read the article

  • How can I tell which interface my Supemicro IPMI is piggybacking on?

    - by lorin
    I've used IPMI before, but only on servers where the IPMI interface had a dedicated ethernet port. I've got an Ubuntu 10.04 server with two ethernet cards, which is supposed to have an IPMI interface on it (the motherboard is a Supermicro H8DMR-I2). From what I understand, the IPMI interface is piggybacking on one of the two NICs. Is there any way I can tell which NIC the IPMI interface is piggybacking on? Using ipmitool I've tried to set the IP address on the IPMI interface for the subnet for eth0, and then the subnet for eth1, and it's never reachable. (Can you even reach an IPMI interface from the same NIC it's piggybacking off of, or do you need to try connecting from a different machine on the network?) Also, is there anything special I need to do to enable it? I can access the IPMI interface locally using "ipmitool".

    Read the article

  • Using Supermicro IPMI behind a Proxy?

    - by Stefan Lasiewski
    This is a SuperMicro server with a X8DT3 motherboard which contains an On-board IPMI BMC. In this case, the BMC is a Winbond WPCM450). I believe many Dell servers use this a similar BMC model. A common practice with IPMI is to isolated it to a private, non-routable network. In our case all IPMI cards are plugged into a private management LAN at 192.168.1.0/24 which has no route to the outside world. If I plug my laptop into the 192.168.1.0/24 network, I can verify that all IPMI features work as expected, including the remote console. I need to access all of the IPMI features from a different network, over some sort of encrypted connection. I tried SSH port forwarding. This works fine for a few servers, however, we have close to 100 of these servers and maintaining a SSH client configuration to forward 6 ports on 100 servers is impractical. So I thought I would try a SOCKS proxy. This works, but it seems that the Remote Console application does not obey my systemwide proxy settings. I setup a SOCKS proxy. Verbose logging allows me to see network activity, and if ports are being forwarded. ssh -v -D 3333 [email protected] I configure my system to use the SOCKS proxy. I confirm that Java is using the SOCKS proxy settings. The SOCKS proxy is working. I connect to the BMC at http://192.168.1.100/ using my webbrowser. I can log in, view the Server Health, power the machine on or off, etc. Since SSH verbose logging is enabled, I can see the progress. Here's where it get's tricky: I click on the "Launch Console" button which downloads a file called jviewer.jnlp. JNLP files are opened with Java Web Start. A Java window opens. The titlebar says says "Redirection Viewer" in the title bar. There are menus for "Video" "Keyboard" "Mouse", etc. This confirms that Java is able to download the application through the proxy, and start the application. 60 seconds later, the application times out and simply says "Error opening video socket". Here's a screenshot. If this worked, I would see a VNC-style window. My SSH logs show no connection attempts to ports 5900/5901. This suggests that the Java application started the VNC application, but that the VNC application ignores the systemwide proxy settings and is thus unable to connect to the remote host. Java seems to obey my systemwide proxy settings, but this VNC application seems to ignore it. Is there any way for me to force this VNC application to use my systemwide proxy settings?

    Read the article

  • Cant access Dell BMC IPMI Over IP

    - by Bobb
    I have Dell R210 with iDRAC BMC (new name for old BMC). Which is on-board feature with shared NIC (I believe). Server is on colocation and I didnt set it up before sent there... So I asked for the remote hands to setup IPMI Over IP. They enabled it, set the IP and everything. The IP is different than main box IP. Also the box is cabled to NIC1 and the BMC supposed to share it (am I right?) I can see new IP in the Open Server Administrator (installed on the box). I tried Supermicro IPMI tool and I tried Dell ipmish.exe command like this ipmish -ip xxx -u root -p calvin sysinfo gives BMC is not detected What could be wrong? is there a diagnostics tool I can try? It must be something obvious. I just never used things like that before.... P.S. I read something about encryptions key in the Dell docs. But I understand that is for encrypted IPMI 2.0 and ipmish can use IPMI 1.5 without encryption.

    Read the article

  • Restrict IPMI access on Dell BMC and iDRAC to an allowed IP range

    - by edgester
    I'm trying to secure the iDRAC's and BMC's on some of my Dell servers (R210, R410, R510). I want to restrict access to IPMI commands to only a few IP addresses. I've successfully restricted access to the iDrac using the instructions from http://support.dell.com/support/edocs/software/smdrac3/idrac/idrac10mono/en/ug/html/racugc2d.htm#wp1181529 , but the IP restrictions do not affect IPMI. A separate management network is not practical at this time because of lack or ports and some Dell BMC's don't offer a separate port. I'm told by my networking group that our switches don't support trunking, so using the vlan tagging is not an option either. Is there a way restrict the IPMI access to a list of allowed addresses? FYI, for various reasons, I have a mix of Dell servers with BMC's, iDrac Express and iDrac enterprise management features.

    Read the article

  • IPMI queries to multiple nodes at once

    - by lorin
    I'm using IPMI to manage some nodes in a cluster. I'd like to be able to submit IPMI queries to all of the nodes in parallel. Something similar to Cluster SSH or tentakel, except that it wraps ipmitool instead of ssh. Are there any tools like that?

    Read the article

  • Multi-Boot through IPMI possible?

    - by yoursort
    Hi, I want to setup a cluster. On each machine Windows XP and Linux should be installed and the OS should be selectable by a boat loader (e.g. grub). All machines have IPMI cards. Is it possible when starting the machines over IPMI to also select the OS to boot? And how? Thanks!

    Read the article

  • ipmi - can't ping or remotely connect

    - by Fidel
    I've tried configuring the IPMI controller to accept remote connections, but I can't even ping it. Here is it status: #/usr/local/bin/ipmitool lan print 2 Set in Progress : Set Complete Auth Type Support : NONE PASSWORD Auth Type Enable : Callback : : User : NONE PASSWORD : Operator : PASSWORD : Admin : PASSWORD : OEM : IP Address Source : Static Address IP Address : 192.168.1.112 Subnet Mask : 255.255.255.0 MAC Address : 00:a0:a5:67:45:25 IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10 BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Enabled Gratituous ARP Intrvl : 8.0 seconds Default Gateway IP : 192.168.1.1 Default Gateway MAC : 00:00:00:00:00:00 802.1q VLAN ID : Disabled 802.1q VLAN Priority : 0 RMCP+ Cipher Suites : 0,1,2,3 Cipher Suite Priv Max : uaaaXXXXXXXXXXX : X=Cipher Suite Unused : c=CALLBACK : u=USER : o=OPERATOR : a=ADMIN : O=OEM # /usr/local/bin/ipmitool user list 2 ID Name Enabled Callin Link Auth IPMI Msg Channel Priv Limit 1 true false true true USER 2 admin true false true true ADMINISTRATOR # /usr/local/bin/ipmitool channel getaccess 2 2 Maximum User IDs : 5 Enabled User IDs : 2 User ID : 2 User Name : admin Fixed Name : No Access Available : callback Link Authentication : enabled IPMI Messaging : enabled Privilege Level : ADMINISTRATOR # /usr/local/bin/ipmitool channel info 2 Channel 0x2 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : multi-session Active Session Count : 0 Protocol Vendor ID : 7154 Volatile(active) Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available Non-Volatile Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available # /usr/local/bin/ipmitool chassis status System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : unknown Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false # arp Address HWtype HWaddress Flags Mask Iface 192.168.1.112 ether 00:A0:A5:67:45:25 C bond0 # /usr/local/bin/ipmitool -I lan -H 192.168.1.112 -U admin -P admin chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status In summary. It exists on the ARP list so arp's are being broadcast. I can't ping it and can't connect to it. Can anyone spot any glaring mistakes in the configuration? Many thanks, Fidel

    Read the article

  • check_mk IPMI PCM sensor reading randomly fails

    - by Julian Kessel
    I use check_mk_agent for monitoring a server with IPMI and the freeipmi-tools installed. As far as I can see, the monitoring randomly detects no value returned by the IPMI Sensor "Temperature_PCH_Temp". That's a problem since it results in a CRITICAL state triggering a notification. The interruption lasts only over one check, the following is always OK. The temperature is in no edge area and neither the readings before the fail nor after show a Temp that is tending to overrun a treshold. Has someone an idea on what could be the reason for this behaviour and how prevent it?

    Read the article

  • ipmi driver on windows 2003 R2

    - by rgmarcha
    ipmiutil complains it doesn't find ipmidrv.sys I see it's on \windows\system32\drivers directory, also on \windows\system32\ipmi directory. But, the driver doesn't appear on the output of driverquery command. Any hint on how to enable it? The hardware is a Dell 1950

    Read the article

  • Supermicro IPMI SSL

    - by churnd
    I have a Supermicro X9SCA-F serverboard and I'm trying to secure Super Doctor III IPMI by using SSL. I generated my own certs (done this many times before), uploaded via the web interface, then it said it needed to restart & I clicked OK, but it never came back up. Right now it's not listening on port 80 or 443 it seems. I also power cycled the box a few times (shutting down & physically removing power for 5 mins), but that didn't seem to help either. Before I did this, it was working fine, so I'm not sure what may have happened?

    Read the article

  • Entering BIOs Setup from Supermicro IPMI KVM

    - by Joshua Lim
    I'm having trouble getting into BIOs Setup from Supermicro IPMI "KVM" - Remote Control Console Redirection. I need to change the boot order to CDROM first. I'm running Windows 2008 server. After some Googling, it says here that the method is to: Press TAB to enter Setup screen. Press Esc twice to take effect. http://www.supermicro.com/support/faqs/faq.cfm?faq=6222 A month ago, I tried that 30-40 times + DEL, over 2 hours, it worked. Now, I've been trying the same key combination for more than an hour, rebooting each time it failed, it still doesn't work. Note: I've only got a notebook computer, no extra monitor.

    Read the article

  • Alternate port numbers for Supermicro IPMI View software

    - by MC9000
    I'm using the IPMI View software to manage a SuperMicro server but would like to use alternate port #s within the program itself. In other words - If I use the web browser, it defaults to port 80 - While I can, say change that port to 12345 (or whatever) and type the IP address into the browser (like http://xxx.xxx.xxx.xxx:12345 ) that works just fine. However, in IPMIView, it will assume port 80 and load the browser with the IP (which, naturally, won't work, so I have to manually type in the alternate port #). I can deal with that. The clincher is if I use a port other than 623 for management - (say 55623 for example), the IPMIView will not find it. Same goes for the iKVM port #. Is there some place to specify this (to tell IPMIView to use the alternate port numbers), like a settings file? I'm running this from a Windows client.

    Read the article

  • supermicro server ipmi problem - problem with keyboard layout

    - by maxs
    hi, we hava a supermicro server (x8dtl-if-O with suse 11): if i connect from my workstation (xppro-german)with the remote console i can not type any öä<... (on the server local - we have no problems - only remote). the keyboard layout of the workstation is german - if i switch the keyboard layout to english i can type öäü.... - but i don't can type <| ?? thx

    Read the article

  • Supermicro IPMI on MBD-X8DAH+-F-O motherboard. Keyboard and mouse do not work after booting Windows Server 2008 R2

    - by LDelgado
    Hell Everyone, I built a server with the mentioned motherboard. I installed Windows Server 2008 R2 Enterprise on this server. IPMI is integrated on the motherboard with its own dedicated NIC. I've got that NIC configured with its own IP address. I can remote into it using IPMI, and I can remotely control the server settings before booting the OS ( BIOS, RAID configuration, etc). When the OS boots, I lose the mouse and keyboard. I cannot use the keyboard or mouse when installing the OS either. So the Keyboard and Mouse only work when no OS is loaded. Once the OS loads I lose it - that is my problem. I've been doing some research and trying a few things, but I have not been successful in fixing this issue. I may be wrong, but based on the things I've found online, it seems that the problem could be caused by the way the OS handles USB. The server is headless. There is no keyboard, mouse, or monitor plugged into it. When I boot up the OS and remote into it, I cannot see a mouse or keyboard listed in the Device Manager. Based on what I've read, it seems that the OS should detect a mouse and a keyboard when connecting remotely via IPMI. The following are the solutions I've tried. Nothing has worked so far: I've updated the firmware of the IPMI component to the latest firmware - 1.33. I made sure that the mouse mode was set to Absolute (Windows OS). I've loaded the factory defaults several times. I've enabled Port64h/60h Emulation under the USB settings in the BIOS. I've disabled USB legacy support in the BIOS. I made sure the firewall wasn't blocking IPMI (disabled the firewall). And that's about it. I've found threads in some forums from people having the same issue as me, but they were not running the same OS. They were either running Linux or FreeBSD. Most of them fixed their problem by selecting the right mouse mode (Linux in their case). There was one other that solved the problem by disabling USB Mass Storage mode. He stated "When I set it to disable USB Mass Storage when no image is loaded, the ukbd came alive, and I'm typing this on the IPMI Console. " source: http://freebsd.1045724.n5.nabble.com/IPMI-Console-No-luck-once-OS-is-booted-td3967868.html I suspect the solution described in the previous paragraph is somehow related to my problem. I've found several threads on the internet with issues describing the same problem, but none of them were with Windows Server 2008 R2. Again, I may be wrong, but it seems like that could be the issue. I just don't know how I go about applying a solution in Windows Server 2008 R2. In any case, I could use your expertise. Maybe I am missing something, or maybe I'm on the right track. Your help is much appreciated. Thank you in advance,

    Read the article

  • IPMI sdr entity 8 (memory module) only showing 3 records?

    - by thinice
    I've got two Dell PE R710's - A has a single socket and 3 DIMMs in one bank B has both sockets and 6 (2 banks @ 3 DIMMs) filled The output from "ipmitool sdr entity 8" confuses me - according to the OpenIPMI documentation these are supposed to represent DIMM slots. Output from A (1 CPU, 3 DIMMS, 1 bank.): ~#: ipmitool sdr entity 8 Temp | 0Ah | ok | 8.1 | 27 degrees C Temp | 0Bh | ns | 8.1 | Disabled Temp | 0Ch | ucr | 8.1 | 52 degrees C Output from B (2 CPUs, 3 DIMMS in both banks, 6 total): ~#: ipmitool sdr entity 8 Temp | 0Ah | ok | 8.1 | 26 degrees C Temp | 0Bh | ok | 8.1 | 25 degrees C Temp | 0Ch | ucr | 8.1 | 51 degrees C Now, I'm starting to think this output isn't DIMMS themselves, but maybe a sensor for each bank and something else? (Otherwise, shouldn't I see 6 readings for the one with both banks active?) The CPU's aren't near 50 deg C, so I doubt the significantly higher reading is due to proximity - Is anyone able to explain what I'm seeing? Does the output from my ipmitool sdr entity 8 -v here on pastebin seem to hint at different sensors? The sensor naming conventions are poor - seems like a dell thing. Here is output from racadm racdump

    Read the article

  • How do I re-enable the IPMI temperature sensors?

    - by NobleUplift
    I've never had a problem reading temperature sensors with ipmitool on my server, but recently the temperature readings started showing up as disabled: # ipmitool sdr list Temp | disabled | ns Temp | disabled | ns Ambient Temp | 21 degrees C | ok CMOS Battery | 0x00 | ok VCORE | 0x00 | ok VDDIO | 0x00 | ok VDDA | 0x00 | ok VTT | 0x00 | ok VCORE | 0x00 | ok VDDIO | 0x00 | ok VDDA | 0x00 | ok VTT | 0x00 | ok VDD 1.2V PG | 0x00 | ok Linear PG | 0x00 | ok I am using OpenIPMI 2.0.19 and ipmitool 1.8.12. How can I re-enable my temperature sensors?

    Read the article

  • where are the "ipmi sel" entries parameter descriptions?

    - by Horatiu
    In order to troubleshoot a possible hardware issue I have installed ipmitools on my server and am doing queries for info related to poweron/poweroffs, hardware added/removed/status. I am trying to find some info on how to interpret sel obtained via ipmi sel list and the output looks like this : 72b4 | 10/31/2013 | 10:42:40 | System Event #0x01 | OEM System boot event | Asserted 72c8 | 10/31/2013 | 10:42:48 | System ACPI Power State #0x82 | S0/G0: working | Asserted I really want to know what "Asserted" means in this context, and also, where can I find a reference with all possible "exit status(es)" ? (Because I think that's what this is, right ?)

    Read the article

  • Formatting data from management database

    - by bVector
    I've got some data that goes like this: Config_Name Question Answer Cisco WAN Sensitivity: High Cisco WAN Authorized Users: Brent, Charles Cisco WAN Last Audited: n/a Cisco WAN Next Audit: 3/30/2012 Cisco WAN Audit Signature: Cisco WAN Username: MYCOMPANY Cisco WAN Password: Cisco WAN Encrypted-A ENCRYPTED DATA Cisco WAN Encrypted-B Cisco WAN Encrypted-C vCenter server Sensitivity: High vCenter server Authorized Users: Brent, Charles vCenter server Last Audited: vCenter server Next Audit: 3/30/2012 vCenter server Audit Signature: ENCRYPTED DATA vCenter server Username: administrator vCenter server Password: vCenter server Encrypted-A ENCRYPTED DATA vCenter server Encrypted-B vCenter server Encrypted-C AKSC-NE01 IPMI Sensitivity: High AKSC-NE01 IPMI Authorized Users: Brent, Charles AKSC-NE01 IPMI Last Audited: AKSC-NE01 IPMI Next Audit: 3/30/2012 AKSC-NE01 IPMI Audit Signature: ENCRYPTED DATA AKSC-NE01 IPMI Username: MYCOMPANY AKSC-NE01 IPMI Password: AKSC-NE01 IPMI Encrypted-A ENCRYPTED DATA AKSC-NE01 IPMI Encrypted-B AKSC-NE01 IPMI Encrypted-C and I need it to be in this format: Config_Name Sensitivity: Authorized Users: Last Audited: Next Audit: Audit Signature: Username: Password: Encrypted-A Encrypted-B Encrypted-C AKSC-NE01 IPMI High Brent, Charles 3/30/2012 ENCRYPTED DATA MYCOMPANY ENCRYPTED DATA Cisco ASA5505 WAN High Brent, Charles n/a 3/30/2012 ENCRYPTED DATA MYCOMPANY ENCRYPTED DATA vCenter server High Brent, Charles 3/30/2012 ENCRYPTED DATA administrator ENCRYPTED DATA the tabs get messed up on here but hopefully you get my drift. does anyone know an easy way to do this? I haven't found one with excel just yet.

    Read the article

  • How do I redirect the kernel console output on Ubuntu 10.04

    - by lorin
    When I reboot my Ubuntu 10.04 nodes, I'd like to be able to see the kernel boot messages when connecting to the IPMI interfaces using Serial Over LAN mode (ttyS0). What do I need to do to be able to redirect these messages to ttyS0? Ideally, I'd like them to also still appear in the usual place (tty0, I think) for when I plug a monitor directly into the box.

    Read the article

  • SuperMicro BMC on OpenSuSE Linux --cannot access from LAN

    - by Kendall
    Hi, I have an (old) SMC-001 IPMI device on an (old) X6DVL-EG2 motherboard. My problem is that I cannot access the BMC from LAN. I'm also getting some interesting output from ipmitool. First, the setup. I enable Console Redirection in the BIOS, turn BIOS Redirection after POSt to "disabled". I then modprobe'ed for ipmi_msghandler, ipmi_devintf and ipmi_si. I then found ipmi0 under /dev. So far so good. Since I want console redirection over serial, I modified /boot/grub/menu.lst: http://pastebin.com/YYJmhusQ I then modified "/etc/inittab" as follows: S1:12345:respawn:/sbin/agetty -L 19200 ttyS1 ansi Networking I set as following, using "ipmitool" ipaddr: 192.168.3.164 netmask: 255.255.255.0 defgw: 192.168.3.1 The above are correct for my environment. To test it I do: ipmitool -I open chassis power off which responds by powering off the machine. When I to access from another computer on the network, however, I get an error message: host# ipmitool -I lanplus -H 192.168.10.164 -U Admin -a chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status "Admin" seems to be a valid user name: host# ipmitool -I open user list 1 2 Admin true false true USER The interesting output from ipmitool I initially mentioned: host # ipmitool -I open lan set 1 access on Set Channel Access for channel 1 failed: Request data field length limit exceeded Also, newload4:/home/gjones # ipmitool channel info 1 Channel 0x1 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : session-less Active Session Count : 0 Protocol Vendor ID : 7154 Get Channel Access (volatile) failed: Request data field length limit exceeded The output of "ipmitool -I open lan print 1" is here: http://pastebin.com/UZyL6yyE Any help/suggestions is greatly appreciated; I've been working with this thing for a few hours now with no success.

    Read the article

  • With the Supermicro Embeded BMC, is it possible to connect to Serial Over Lan via SSH?

    - by Stefan Lasiewski
    I have several dozen Supermicro servers which use the Supermicro Embedded BMC. The documentation on that page suggests that I can access the Serial Over LAN (Serial Console) over SSH: SMASH and CLP support SSH based SOL Power control of the server But when I ssh into my BMC, all I see is a Busybox implementation, with no clear ability to connect to the SOL: # ssh 192.168.100.100 -l ADMIN [email protected]'s password: BusyBox v1.1.3 (2011.02.12-01:48+0000) Built-in shell (ash) Enter 'help' for a list of built-in commands. # show -sh: show: not found # smash -sh: smash: not found Supermicro support is giving me inconsistent answers. Is it possible to connect to the SOL via the SSH interface?

    Read the article

  • How to modify IMM password from the default one?

    - by evachristine
    We cannot modify the default USERID/PASSW0RD on an IMM because when we try it modify the USERID's password with a logged in USERID user (that has the "max" rights) we get this message after clicking on "SAVE" (save the new password..) Could not modify password: *** Provider OSBase_AccountProvider(21770) exiting due to a SIGSEGV signal Our question: How can we modify the default password to something else? UPDATE: by IMM we wanted to mean this: https://en.wikipedia.org/wiki/IBM_Remote_Supervisor_Adapter#Integrated_Management_Module_.28IMM.29

    Read the article

1 2  | Next Page >