Search Results

Search found 7 results on 1 pages for 'mdpc'.

Page 1/1 | 1 

  • NETAPP Fragmentation

    - by mdpc
    We all know that once a disk (or storage system for that matter) gets introduced into use, the performance degrades due to fragmentation of files. This seems to be why disk defragmentors are in fairly wide use on Windows boxes. And they do increase the performance substancially. As an aside, I haven't heard of many defragmentors in the Unix/Linux area. Despite the claimed WAFL protections for the NetApp, file fragmentation still will occur, especially with all the sparsely crated VMs. My question is does anybody do any sort of defragmention of such a storage system? Do you notice any measurable degration/improvement of either not doing/doing anything to address this situation? Does anybody do anything about it? If so what? Thanks

    Read the article

  • OSX 10.6 integration into NIS/netgroup/automount infrastructure

    - by mdpc
    I have an existing infrastructure where accounts are maintained under NIS (yp) with no local unix accounts. Also, all the standard maps including hosts, mail aliases, netgroups, etc...are maintained in this form. Extensive use of the UNIX/Linux automounter with items scattered over the network on NFS servers. There are NO ACLs on any local or shared files. All mail needs to use basically the nullclient sendmail configuration feeding into a different system. I now have a requirement to integrate an Apple OSX 10.6 system into this environment and make it run seamlessly. My initial reading and second-hand information seems to indicate that this may not be possible on the native OSX 10.6 system. I'm concerned. Any ideas as to how to accomplish this task and make everybody happy? Thanks PS: I have never used an Apple OSX system.

    Read the article

  • OSX 10.6 integration into NIS/netgroup/automount infrastructure

    - by mdpc
    I have an existing infrastructure where accounts are maintained under NIS (yp) with no local unix accounts. Also, all the standard maps including hosts, mail aliases, netgroups, etc...are maintained in this form. Extensive use of the UNIX/Linux automounter with items scattered over the network on NFS servers. There are NO ACLs on any local or shared files. All mail needs to use basically the nullclient sendmail configuration feeding into a different system. I now have a requirement to integrate an Apple OSX 10.6 system into this environment and make it run seamlessly. My initial reading and second-hand information seems to indicate that this may not be possible on the native OSX 10.6 system. I'm concerned. Any ideas as to how to accomplish this task and make everybody happy? Thanks PS: I have never used an Apple OSX system.

    Read the article

  • crontab: question about a special case of the dash character in the time field spec

    - by mdpc
    In the SuSE /etc/crontab the entry to run the cron.{hourly,daily,monthly,weekly} scripts is coded as: -*/15 * * * * root test -x /usr/lib/cron/run-crons && /usr/lib/cron/run-crons /dev/null 2&1 Notice that the very first character of the specification is a dash character (-), and this is NOT a typo. Can somebody explain what the time spec '-*/15' means? BTW, the stuff seems to be running fine. Thanks

    Read the article

  • Replacement for NIS/YP

    - by mdpc
    The company that I am working for is embarking on replacing the current locally developed NIS/YP structure with LDAP. We already have AD in house for the Windows stuff and would like to consider using an AD system. The AD people are quite restrictive and would not support extensive modifications. We have needs to have the replacement include the support the full capabilities of the NIS/YP suite include netgroups, login restrictions to specific servers for specific users or groups of users, consistent passwords between the *nix and Windows environment,etc. Our environment is a mixture of Linux (suse, RH, Debian), Sun, IBM, HP and MPRAS as well as a NETAPP. So whatever we use must be totally inclusive to all environment. We have looked at Likewise, but our management wants other alternatives to compare with. What other things should I be looking at and what is you assessment of the alternative? Thanks

    Read the article

  • What is the solution to enable Dymo Turbo 400 Label Printer to work on Win 7 / 64-bit?

    - by mdpc
    It's Christmas time and time for printing labels for all those Christmas cards. I've upgraded to Windows 7 64-bit from XP. I've been unsuccessfully attempting to get the connected Dymo 400 Turbo label USB printer to work again. The latest manufacturer drivers have been successfully loaded and installed. The drivers are supposed to work on Windows 7/64-bit. The Win 7 system(s) in question are patched and up-to-date on that score. The Windows Update site responds with a driver when the USB cable is connected to this printer. The printer queue seems to be established correctly. What happens is that I submit a job to the printer (either using the DYMO s/w or not), it delays for a period of time, and then I get the message 'printing error'. Can't seem to locate the appropriate error in the new and improved event log. Several combinations of rebooting, re-installation and power cycling components fail to make the printer work. Sometimes during some type of reset it spits out the last thing to be submitted, but that seems intermittent. I have tried different USB cables and different USB (2.X) ports as well. I have run the Windows 7 troubleshooter it tries to fix the problem but alas it doesn't. Interestingly, trying the USB printer (and its associated manufacturer drivers and s/w) on another Windows 7 64-bit system has the identical failures noticed on the original system. I did not find anything on the manufacturers' site concerning this problem. The printer has no hardware problems or issues.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

1