Search Results

Search found 28 results on 2 pages for 'megaraid'.

Page 1/2 | 1 2  | Next Page >

  • LSI MegaRAID Expected Chip Temperature?

    - by Myles Gray
    We recently built a replicating SAN array from 2x Dell R720XD's, we are using LSI 9270-8i MegaRAID cards with CacheCade 2.0, BBU and Write Back cache enabled. Our cards are showing HUGE chip temperatures (97*C+ with NO disk activity!). Our R720's are in auto temp management mode so the max exhaust temp is 50*C. The MegaRAID cards are passively cooled and depend on good airflow to cool them - however is 97*C normal? - I have seen reference to 60*C max ambients but nothing for chip temp.

    Read the article

  • Migrating RAID6 array from HP SmartArray P600 to LSI MegaRAID SAS 8888ELP

    - by MLu
    My customer has an external RAID6 array (8x 1TB in HP MSA60 enclosure) attached to HP SmartArray P600 controller. They have now decided to replace the server and the new one comes with LSI MegaRAID SAS 8888ELP. The HW supplier insists the migration is as simple as pulling the eSATA cable from P600 and inserting it into LSI but I'm not convinced. Unfortunately I have nowhere to test, and will have to do the exercise on the production array :( So the question in brief - is it possible to import the HP SmartArray P600-created RAID6 array to LSI MegaRAID 8888ELP?

    Read the article

  • LSI MegaRAID LINUX got Optimal after degradation but strange POST message

    - by kesrut
    Linux server box with LSI MegaRAID controller got degraded. But after some time RAID status changed to Optimal. Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 2.727 TB Mirror Data : 2.727 TB State : Optimal Strip Size : 256 KB Number Of Drives per span:2 Span Depth : 3 Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No But now I'm getting RAID BIOS POST message: Your battery is either charging, bad or missing, and you have VDs configured for write-back mode. Because the battery is not currently usable, these VDs willl actually run in write-through mode until the battery is fully charged or replaced if it is bad or missing. (Image: http://cl.ly/image/1h1O093b1i2d) So may it be battery issue caused problem ? I get information about battery: BatteryType: iBBU Voltage: 4001 mV Current: 0 mA Temperature: 22 C Battery State : Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No Where can be problem ? I'm disabled alarms, but get them if enabled. But don't know how find root of problem.

    Read the article

  • Horrible performing RAID

    - by Philip
    I have a small GlusterFS Cluster with two storage servers providing a replicated volume. Each server has 2 SAS disks for the OS and logs and 22 SATA disks for the actual data striped together as a RAID10 using MegaRAID SAS 9280-4i4e with this configuration: http://pastebin.com/2xj4401J Connected to this cluster are a few other servers with the native client running nginx to serve files stored on it in the order of 3-10MB. Right now a storage server has a outgoing bandwith of 300Mbit/s and the busy rate of the raid array is at 30-40%. There are also strange side-effects: Sometimes the io-latency skyrockets and there is no access possible on the raid for 10 seconds. The file system used is xfs and it has been tuned to match the raid stripe size. Does anyone have an idea what could be the reason for such a bad performing array? 22 Disks in a RAID10 should deliver way more throughput.

    Read the article

  • How to create Raid 10 with megacli

    - by Henno
    I have OpenFiler storage server. Without installing Windows and MSM, I want to create raid10 array from disks 2 to 21. I have already successfully installed MegaCli to OpenFiler but I'm stuck in figuring out the correct command line for creating a raid 10 array. The documentations says that the syntax for creating a raid 10 is: MegaCli -CfgSpanAdd -r10 -Array0[E:S,E:S] -Array1[E:S,E:S] -aN My enclosure ID is 25, so: [root@linux-h5ut ~]# MegaCli -CfgSpanAdd -r10 -Array0[E25:S02,E25:S21] -Array1[E25:S02,E25:S21] WB Cached NoCachedBadBBU -a0 Invalid input at or near token E I have googled high and low but there doesn't seem to be any example doing raid10 with megaraid (only the syntax). Can anyone explain what is wrong?

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Install MegaCli to Monitor Perc 5/i in Nexentastor 3

    - by Peter Valadez
    I have a Dell 2950 with a Perc 5/i Raid controller that we've already installed Nexentastor 3 Community Edition on. We setup a raid-10 array that and put a ZFS pool on top of the hardware. As I understand, in this configuration ZFS/Nexentastor will not be able to tell when a disk fails in the array. Obviously, this is not optimal. Since the Dell Perc 5/i controller is a rebranded LSI controller, you should be able to use the MegaCli utility to manage the array and monitor its condition. I had seen in a separate forum that the Perc 5/i is very similar to the LSI MegaRAID 8480E, so I tried installing the MegaCli utility at the link below. However, I have not been able to successfully install the utility. http://www.lsi.com/support/products/Pages/MegaRAIDSAS8480E.aspx Here is what happened when I tried to install MegaCli: root@Nexenta2:/files# pkgadd -d MegaCli.pkg Warning: unable to relocate '$BASEDIR' mv: cannot move `solmegacli-8.02.16/' to a subdirectory of itself, `solmegacli-8.02.16//var/lib/dpkg/alien/solmegacli/reloc/solmegacli-8.02.16' mv: cannot move `solmegacli-8.02.16/' to a subdirectory of itself, `solmegacli-8.02.16//opt/solmegacli-8.02.16' 822-date: warning: This program is deprecated. Please use 'date -R' instead. 822-date: warning: This program is deprecated. Please use 'date -R' instead. solmegacli_8.02.16-1_all.deb generated (Reading database ... 41397 files and directories currently installed.) Preparing to replace solmegacli 8.02.16-1 (using solmegacli_8.02.16-1_all.deb) ... Unpacking replacement solmegacli ... Setting up solmegacli (8.02.16-1) ... In /var/logs/dpkg.log: 2012-03-23 20:40:19 status unpacked solmegacli 8.02.16-1 2012-03-23 20:40:19 configure solmegacli 8.02.16-1 8.02.16-1 2012-03-23 20:40:19 status unpacked solmegacli 8.02.16-1 2012-03-23 20:40:19 status half-configured solmegacli 8.02.16-1 2012-03-23 20:40:19 status installed solmegacli 8.02.16-1 So... I've got three questions: Is it possible to install and use MegaCli in Nexentastor 3? If so, how can I install MegaCli on Nexentastor 3? Suggestions welcome!!! If not, is there a better way to monitor the condition of the Perc 5/i hardware raid? Our 2950 does have a DRAC card, so can I use that to monitor the raid condition?

    Read the article

  • MegaCLI always returns blank output

    - by JamesHannah
    This server is a Dell R200 running Ubuntu 8.04LTS using a LSI SAS1068E raid card supplied from Dell, I suspect that there might be some kind of RAID issue with the hardware raid built into the motherboard, but I can't seem to get MegaCLi to return any useful output: root@81 $ ./MegaCli -AdpAllInfo -aALL root@81 $ ./MegaCli -PDList -aALL root@81 $ The disks work and AFAIK the raid software is installed correctly. I've seen this issue on RedHat issues also in the past. The RAID was initially setup through the BIOS on this server and appears to be functioning fine apart from this.

    Read the article

  • Hard drives indication with controller MegaRAID SAS 9261-8i on HP Proliant DL320e Gen8. Is it possible?

    - by ame
    Give me advice, please. My situation: There're the server HP ProLiant DL320e Gen8 and MegaRAID SAS 9261-8i RAID Controller. I installed Controller into server and I reconnected Mini-SAS cord from block of hard drives to controller, but I haven't any indication of hard discs on server front panel. There's indication of activity of drives only during boot of server. Controller has 2-pin connector (JT6B3, SAS Activity LED header) but where and how can I connect it? Thanx.

    Read the article

  • smartctl not actually running self tests?

    - by canzar
    I want to run the smartctl self tests to check the health of the drives in my RAID array (PERC 5/i). The array is on sda and comprises six drives. I can check the status using sudo smartctl /dev/sda -d megaraid,0 -a And I see that SMART is available and enabled on all the drives. I have tried to run self tests using sudo smartctl /dev/sda -d megaraid,0 -t short and sudo smartctl /dev/sda -d megaraid,0 -t long I have also tried it on all of the drives 0-5. No matter what I try, when I run: sudo smartctl /dev/sda -d megaraid,0 -l selftest I always get the same result, which seems to always report that I have never run a self test. /dev/sda [megaraid_disk_00] [SAT]: Device open changed type from 'megaraid' to 'sat' ===START OF READ SMART DATA SECTION === SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] From what I read, I should have no problem running the short and long self tests on the array while it is mounted. Does anyone else have experience running these tests on a PERC 5/i raid array who could lend some insight into what is causing the problem? (smartmontools release 5.40 dated 2009-12-09 at 21:00:32 UTC)

    Read the article

  • megacli forceWB

    - by Pascal den Bekker
    We are using a raid controller: LSI Logic / Symbios Logic MegaRAID SAS 2008 But there is no BBU on Board, is there a way to force the WB Cache ?? I tried following: - /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp CachedBadBBU -L0 -a0 Failed to set Write Cache OK if bad BBU on Adapter 0, VD 0. FW error description: The requested command has invalid arguments. Can anyone help? Cheers, Pascal

    Read the article

  • ?????Exadata????

    - by Liu Maclean(???)
    ??check Exadata Image & OS versions , GI & DB patches sundiag exacheck cellserv ==> imageinfo dbhost ==> /usr/local/bin/imagehistory Also check the version of the switch. Login to Switch and execute the following command [root@myswitch-1 sbin]# version [root@dmorlsw-ib2 sbin]# cd /usr/local/bin [root@dmorlsw-ib2 bin]# ls -lrt version -rwxr-xr-x 1 root root 20356 Apr 4 2011 version Output will look as below. [root@dmorlsw-ib2 ~]# version SUN DCS 36p version: 1.3.3-2 Build time: Apr 4 2011 11:15:19 SP board info: Manufacturing Date: 2009.05.05 Serial Number: "NCD3X0178" Hardware Revision: 0x0006 Firmware Revision: 0x0102 BIOS version: NOW1R112 BIOS date: 04/24/2009 ib8# cat /sys/class/infiniband/is4_0/fw_ver 7.2.300 ib8 # cat /sys/class/dmi/id/bios_version NOW1R112 ib8 # nm2version NM2-36p version: 1.0.1-1 Build time: Sep 14 2009 12:52:51 ComExpress info: Manufacturing Date: 2009.08.19 Serial Number: Hardware Revision: 0x0006 Firmware Revision: 0x0102 { case `uname` in Linux ) ILOM="/usr/bin/ipmitool sunoem cli" ;; SunOS ) ILOM="/opt/ipmitool/bin/ipmitool sunoem cli" ;; esac ; ImageInfo="/opt/oracle.cellos/imageinfo" ; uname -srm ; head -1 /etc/*release ; uptime | cut -d, -f1 ; $ILOM "show /SP system_description system_identifier" | grep = ; $ImageInfo -activated -node -status -ver | grep -v ^$ ; } | tee /tmp/ExaInfo.log $GRID_HOME/OPatch/opatch lsinv -all -oh $GRID_HOME | tee /tmp/OPatchInv.log $ORACLE_HOME/OPatch/opatch lsinv -all | tee -a /tmp/OPatchInv.log cat /tmp/ExaInfo.log Linux 2.6.18-128.1.16.0.1.el5 x86_64 ==> /etc/enterprise-release <== Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) ==> /etc/redhat-release <== Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) 20:37:56 up 458 days system_description = SUN FIRE X4170 SERVER, ILOM v3.0.6.10.b, r52264 system_identifier = Sun Oracle Database Machine Active image version: 11.2.1.2.3 Active image activated: XXXX-XX-XX 12:27:12 +0800 Active image status: success Active node type: COMPUTE Inactive image version: undefined FileName: OPatchInv.log ---------------- ... Oracle Home       : /u01/app/11.2.0/grid Central Inventory : /u01/app/oraInventory   from           : /etc/oraInst.loc OPatch version    : 11.2.0.1.2 OUI version       : 11.2.0.1.0 OUI location      : /u01/app/11.2.0/grid/oui ... -------------------------------------------------------------------------------- List of Oracle Homes:   Name                                       Location   Ora11g_gridinfrahome1         /u01/app/11.2.0/grid   OraDb11g_home1                  /u01/app/oracle/product/11.2.0/dbhome_1 -------------------------------------------------------------------------------- Installed Top-level Products (1): Oracle Grid Infrastructure                                           11.2.0.1.0 ... Interim patches (2) : Patch  9524394      : applied on Thu Jun 03 20:46:05 CST 2010 ... {TRACKING BUG FOR 11.2.0.1 DB MACHINE BUNDLE PATCH 3} Patch  9455587      : applied on Fri Apr 02 18:27:47 CST 2010 ... {MERGE REQUEST ON TOP OF 11.2.0.1.0 FOR BUGS 8483425 8667622 8702731 8730804} Rac system comprising of multiple nodes  Local node = dbserv01  Remote node = dbserv02  Remote node = dbserv03  Remote node = dbserv04 -------------------------------------------------------------------------------- OPatch succeeded. ... Oracle Home       : /u01/app/oracle/product/11.2.0/dbhome_1 ... Oracle Database 11g                                                  11.2.0.1.0 ... Interim patches (5) : Patch  8888434      : applied on Sat Jan 08 00:27:33 CST 2011 ... {AIX-ASM-CF: LMHB TERMINATE INSTANCE WHEN OFFLINE ONE FAILGROUP IN ASM DG} Patch  8730312      : applied on Thu Jun 03 21:30:03 CST 2010 ... {FWD MERGE FOR BASE BUG 8715387 FOR 12G} Patch  9502717      : applied on Thu Jun 03 21:25:54 CST 2010 ... {LMS HIT ORA-600 [KJBLDRMNEXTPKEY:SEEN] AND CRASHED THE INSTANCE} { + same 2 as GI above} ?? cell server Cache Policy cell08# MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU cell09# MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Cache policy is in WB Would recommend proactive  battery repalcement. Example : a. /opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp  -Cache -LALL -aALL ####( Will list the cache policy) b. /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp  -WB  -LALL -aALL ####( Will try to change teh policy from xx to WB)     So policy Change to WB will not come into effect immediately     Set Write Policy to WriteBack on Adapter 0, VD 0 (target id: 0) success     Battery capacity is below the threshold value ??cell BBU??????: cell08# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 BBU status for Adapter: 0 BatteryType: iBBU Voltage: 4061 mV Current: 0 mA Temperature: 36 C BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : Yes Periodic Learn Required : No Battery state: GasGuageStatus: Fully Discharged : No Fully Charged : Yes Discharging : Yes Initialized : Yes Remaining Time Alarm : No Remaining Capacity Alarm: No Discharge Terminated : No Over Temperature : No Charging Terminated : No Over Charged : No Relative State of Charge: 99 % Charger System State: 49168 Charger System Ctrl: 0 Charging current: 0 mA Absolute state of charge: 21 % Max Error: 2 % Exit Code: 0x00 ????BBU ??: dcli -g ~/cell_group -l root -t '{ uname -srm ; head -1 /etc/*release ; uptime | cut -d, -f1 ; imagehistory ; ipmitool sunoem cli "show /SP system_description system_identifier" | grep = ; ipmitool sunoem cli "show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 | egrep -i 'BBU|Battery|Charge:|Fully|Low|Learn' ; }' | tee /tmp/ExaInfo.log Target cells: ['cellserv01', 'cellserv02', 'cellserv03', 'cellserv04', 'cellserv05', 'cellserv06', 'cellserv07'] cellserv01: Linux 2.6.18-128.1.16.0.1.el5 x86_64 cellserv01: ==> /etc/enterprise-release <== cellserv01: Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) cellserv01: cellserv01: ==> /etc/redhat-release <== cellserv01: Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) cellserv01: 01:17:39 up 635 days cellserv01: Version : 11.2.1.2.1 cellserv01: Image activation date : 2011-03-25 11:59:34 -0800 cellserv01: Imaging mode : fresh cellserv01: Imaging status : success cellserv01: cellserv01: Version : 11.2.1.2.3 cellserv01: Image activation date : 2011-04-13 12:15:46 +0800 cellserv01: Imaging mode : patch cellserv01: Imaging status : success cellserv01: cellserv01: Version : 11.2.1.2.6 cellserv01: Image activation date : 2011-05-27 23:08:22 +0800 cellserv01: Imaging mode : patch cellserv01: Imaging status : success cellserv01: cellserv01: system_description = SUN FIRE X4275 SERVER, ILOM v3.0.6.10.b, r52264 cellserv01: system_identifier = Sun Oracle Database Machine cellserv01: Connected. Use ^D to exit. cellserv01: -> show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED cellserv01: show: No matching properties found. cellserv01: cellserv01: -> Session closed cellserv01: Disconnected cellserv01: BBU status for Adapter: 0 cellserv01: BatteryType: iBBU cellserv01: BBU Firmware Status: cellserv01: Learn Cycle Requested : No cellserv01: Learn Cycle Active : No cellserv01: Learn Cycle Status : OK cellserv01: Learn Cycle Timeout : No cellserv01: Battery Pack Missing : No cellserv01: Battery Replacement required : No cellserv01: Remaining Capacity Low : Yes cellserv01: Periodic Learn Required : No cellserv01: Battery state: cellserv01: Fully Discharged : No cellserv01: Fully Charged : Yes cellserv01: Relative State of Charge: 99 % cellserv01: Absolute state of charge: 21 % dcli -l root -g /root/all_group '/opt/MegaRAID/MegAaCli/MegaCli64 -AdpBbuCmd -a0' > BBU.out check ipmi: dcli -g ~/cell_group -l root -t '{ > ipmitool sunoem cli "show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED" | grep = ; MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' ; }' | tee /tmp/ExaCells.log

    Read the article

  • Megacli is killing me, any help appreciated

    - by Stefan
    I run a server with 2 drives in raid0 configured through BIOS. I just added 2 more drives using hotplug (the server is dell r610 with RHEL 5.4 64bit) and I would like to configure a separate raid0 partition on these drives. I am getting the following error: /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd r0[32:2, 32:3] -a0 The specified physical disk does not have the appropriate attributes to complete the requested command. Exit Code: 0x26 All the parameters are correct and there is just no reason why this command could not work, see this (fujitsu is current raid, seagate is the new one I want to create): /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL | egrep 'Adapter|Enclosure|Slot|Inquiry' Adapter #0 Enclosure Device ID: 32 Slot Number: 0 Enclosure position: 0 Inquiry Data: FUJITSU MBD2147RC D807D0A4PA101174 Enclosure Device ID: 32 Slot Number: 1 Enclosure position: 0 Inquiry Data: FUJITSU MBD2147RC D807D0A4PA10115T Enclosure Device ID: 32 Slot Number: 2 Enclosure position: 0 Inquiry Data: SEAGATE ST9300603SS FS033SE0TF5K Enclosure Device ID: 32 Slot Number: 3 Enclosure position: 0 Inquiry Data: SEAGATE ST9300603SS FS023SE070FK I also tried to set up the drive as hotspare, also some strange error: /opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set -physdrv[32:3] -a0 Adapter: 0: Set Physical Drive at EnclId-32 SlotId-3 as Hot Spare Failed. FW error description: The specified device is in a state that doesn't support the requested command. Exit Code: 0x32 As you can see the disk is in Unconfigured, Good state: Enclosure Device ID: 32 Slot Number: 3 Enclosure position: 0 Device Id: 3 Sequence Number: 1 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.875 GB [0x22dc0000 Sectors] Firmware state: Unconfigured(good), Spun Up SAS Address(0): 0x5000c50005cd20b1 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST9300603SS FS023SE070FK FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: Foreign Foreign Secure: Drive is not secured by a foreign lock key Device Speed: Unknown Link Speed: Unknown Media Type: Hard Disk Device Drive Temperature :30C (86.00 F)

    Read the article

  • LSI RAID monitor reports "Consistency Check inconsistency logging disabled"

    - by carlpett
    I have a server with a LSI MegaRAID 9261-8i controller. Recently I started getting alerts like this one: Controller ID: 1 Consistency Check inconsistency logging disabled, too many inconsistencies on VD: 0 Generated on:Sat May 12 04:06:40 2012 SYSTEM DETAILS--- IP Address: 192.168.1.29 OS Name: Windows 7 x64 OS Version: 6.01 Driver Name: megasas.sys Driver Version: 4.5.1.64 IMAGE DETAILS--- BIOS Version: 2.120.33-1197 Firmware Package Version: 12.12.0-0045 Firmware Version: 3.21.00_4.11.05.00_0x05000000 VD 0 is a RAID mirror containing the system disk. I have searched and read, but cannot find any trace of how to actually do anything about this. I tried running a scandisk but that did not find anything (as I expected, since scandisk reads the disks as exposed by the controller, right?). The MegaRAID Storage Manager does not as far as I can see have any options for checking or fixing physical disks. The program claims the VD is "healty", and both disks have Error count 0. Also a bit strange is the System details in the message... The IP address is associated with the RAS (dial in) interface, and the OS should be Windows Server 2011 SBS. Has anyone else experienced this before? What can be done?

    Read the article

  • NFS high CPU usage

    - by user269836
    Hello, I have a very strange issue. I have next server: Intel(R) Xeon(TM) MP CPU 3.16GHz cat /proc/cpuinfo | grep proce | wc -l 8 free -m total used free shared buffers cached Mem: 28203 27606 596 0 10789 9714 -/+ buffers/cache: 7103 21100 Swap: 24695 0 24695 RAID card *-storage description: RAID bus controller product: MegaRAID vendor: LSI Logic / Symbios Logic physical id: 7 bus info: pci@0000:13:07.0 logical name: scsi2 version: 01 width: 32 bits clock: 66MHz capabilities: storage pm bus_master cap_list rom configuration: driver=megaraid latency=32 resources: irq:134 memory:d8ff0000-d8ffffff(prefetchable) memory:df600000-df60ffff(prefetchable) HDD: 10x148Gb SCSI U320 15k - RAID5 /dev/sdb1 807G 674G 93G 88% /storage /dev/sdb1 /storage ext4 defaults,usrjquota=aquota.user,grpjquota=aquota.group,jqfmt=vfsv0,noatime,nodiratime,noacl,errors=remount-ro 0 1 network cards ethtool -i eth0 driver: tg3 version: 3.116 firmware-version: 5704-v3.36, ASFIPMIc v2.36 bus-info: 0000:10:02.0 ethtool -i eth1 driver: tg3 version: 3.116 firmware-version: 5704-v3.36, ASFIPMIc v2.36 bus-info: 0000:10:02.0 ifconfig bond0 Link encap:Ethernet HWaddr 00:0f:1f:ff:d6:4d inet addr:192.168.15.71 Bcast:192.168.15.255 Mask:255.255.255.0 inet6 addr: fe80::20f:1fff:feff:d64d/64 Scope:Link UP BROADCAST RUNNING MASTER MULTICAST MTU:1500 Metric:1 RX packets:1062818202 errors:0 dropped:3918 overruns:0 frame:0 TX packets:1041317321 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:10000 RX bytes:258867684559 (241.0 GiB) TX bytes:396569192650 (369.3 GiB) this server running only nfs-kernel-server uname -a Linux nas2-backup 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux Debian 6. What do I have, once per day or two, LA goes up, it can be reached around LA: 40 but if I do: nfs-kernel-server restart. Every thing is OK. But on the next day or a little bit later, LA goes up again. Servers are connected to d-link dgs 1016d with 24 GBits ports. I have tried everything to find out what the problem is. Why it's happening, but still I can not resolve this issue. Any ideas on what is happening here?

    Read the article

  • Strange Recurrent Excessive I/O Wait

    - by Chris
    I know quite well that I/O wait has been discussed multiple times on this site, but all the other topics seem to cover constant I/O latency, while the I/O problem we need to solve on our server occurs at irregular (short) intervals, but is ever-present with massive spikes of up to 20k ms a-wait and service times of 2 seconds. The disk affected is /dev/sdb (Seagate Barracuda, for details see below). A typical iostat -x output would at times look like this, which is an extreme sample but by no means rare: iostat (Oct 6, 2013) tps rd_sec/s wr_sec/s avgrq-sz avgqu-sz await svctm %util 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.00 0.00 156.00 9.75 21.89 288.12 36.00 57.60 5.50 0.00 44.00 8.00 48.79 2194.18 181.82 100.00 2.00 0.00 16.00 8.00 46.49 3397.00 500.00 100.00 4.50 0.00 40.00 8.89 43.73 5581.78 222.22 100.00 14.50 0.00 148.00 10.21 13.76 5909.24 68.97 100.00 1.50 0.00 12.00 8.00 8.57 7150.67 666.67 100.00 0.50 0.00 4.00 8.00 6.31 10168.00 2000.00 100.00 2.00 0.00 16.00 8.00 5.27 11001.00 500.00 100.00 0.50 0.00 4.00 8.00 2.96 17080.00 2000.00 100.00 34.00 0.00 1324.00 9.88 1.32 137.84 4.45 59.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22.00 44.00 204.00 11.27 0.01 0.27 0.27 0.60 Let me provide you with some more information regarding the hardware. It's a Dell 1950 III box with Debian as OS where uname -a reports the following: Linux xx 2.6.32-5-amd64 #1 SMP Fri Feb 15 15:39:52 UTC 2013 x86_64 GNU/Linux The machine is a dedicated server that hosts an online game without any databases or I/O heavy applications running. The core application consumes about 0.8 of the 8 GBytes RAM, and the average CPU load is relatively low. The game itself, however, reacts rather sensitive towards I/O latency and thus our players experience massive ingame lag, which we would like to address as soon as possible. iostat: avg-cpu: %user %nice %system %iowait %steal %idle 1.77 0.01 1.05 1.59 0.00 95.58 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sdb 13.16 25.42 135.12 504701011 2682640656 sda 1.52 0.74 20.63 14644533 409684488 Uptime is: 19:26:26 up 229 days, 17:26, 4 users, load average: 0.36, 0.37, 0.32 Harddisk controller: 01:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 1078 (rev 04) Harddisks: Array 1, RAID-1, 2x Seagate Cheetah 15K.5 73 GB SAS Array 2, RAID-1, 2x Seagate ST3500620SS Barracuda ES.2 500GB 16MB 7200RPM SAS Partition information from df: Filesystem 1K-blocks Used Available Use% Mounted on /dev/sdb1 480191156 30715200 425083668 7% /home /dev/sda2 7692908 437436 6864692 6% / /dev/sda5 15377820 1398916 13197748 10% /usr /dev/sda6 39159724 19158340 18012140 52% /var Some more data samples generated with iostat -dx sdb 1 (Oct 11, 2013) Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sdb 0.00 15.00 0.00 70.00 0.00 656.00 9.37 4.50 1.83 4.80 33.60 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 12.00 836.00 500.00 100.00 sdb 0.00 0.00 0.00 3.00 0.00 32.00 10.67 9.96 1990.67 333.33 100.00 sdb 0.00 0.00 0.00 4.00 0.00 40.00 10.00 6.96 3075.00 250.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 2.62 4648.00 500.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 1.00 0.00 16.00 16.00 1.69 7024.00 1000.00 100.00 sdb 0.00 74.00 0.00 124.00 0.00 1584.00 12.77 1.09 67.94 6.94 86.00 Characteristic charts generated with rrdtool can be found here: iostat plot 1, 24 min interval: http://imageshack.us/photo/my-images/600/yqm3.png/ iostat plot 2, 120 min interval: http://imageshack.us/photo/my-images/407/griw.png/ As we have a rather large cache of 5.5 GBytes, we thought it might be a good idea to test if the I/O wait spikes would perhaps be caused by cache miss events. Therefore, we did a sync and then this to flush the cache and buffers: echo 3 > /proc/sys/vm/drop_caches and directly afterwards the I/O wait and service times virtually went through the roof, and everything on the machine felt like slow motion. During the next few hours the latency recovered and everything was as before - small to medium lags in short, unpredictable intervals. Now my question is: does anybody have any idea what might cause this annoying behaviour? Is it the first indication of the disk array or the raid controller dying, or something that can be easily mended by rebooting? (At the moment we're very reluctant to do this, however, because we're afraid that the disks might not come back up again.) Any help is greatly appreciated. Thanks in advance, Chris. Edited to add: we do see one or two processes go to 'D' state in top, one of which seems to be kjournald rather frequently. If I'm not mistaken, however, this does not indicate the processes causing the latency, but rather those affected by it - correct me if I'm wrong. Does the information about uninterruptibly sleeping processes help us in any way to address the problem? @Andy Shinn requested smartctl data, here it is: smartctl -a -d megaraid,2 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:13 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 20 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 1236631092 Blocks received from initiator = 1097862364 Blocks read from cache and sent to initiator = 1383620256 Number of read and write commands whose size <= segment size = 531295338 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36556.93 number of minutes until next internal SMART test = 32 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 509271032 47 0 509271079 509271079 20981.423 0 write: 0 0 0 0 0 5022.039 0 verify: 1870931090 196 0 1870931286 1870931286 100558.708 0 Non-medium error count: 0 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36538 - [- - -] # 2 Background short Completed 16 36514 - [- - -] # 3 Background short Completed 16 36490 - [- - -] # 4 Background short Completed 16 36466 - [- - -] # 5 Background short Completed 16 36442 - [- - -] # 6 Background long Completed 16 36420 - [- - -] # 7 Background short Completed 16 36394 - [- - -] # 8 Background short Completed 16 36370 - [- - -] # 9 Background long Completed 16 36364 - [- - -] #10 Background short Completed 16 36361 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes] smartctl -a -d megaraid,3 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:26 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 19 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 288745640 Blocks received from initiator = 1097848399 Blocks read from cache and sent to initiator = 1304149705 Number of read and write commands whose size <= segment size = 527414694 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36596.83 number of minutes until next internal SMART test = 28 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 610862490 44 0 610862534 610862534 20470.133 0 write: 0 0 0 0 0 5022.480 0 verify: 2861227413 203 0 2861227616 2861227616 100872.443 0 Non-medium error count: 1 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36580 - [- - -] # 2 Background short Completed 16 36556 - [- - -] # 3 Background short Completed 16 36532 - [- - -] # 4 Background short Completed 16 36508 - [- - -] # 5 Background short Completed 16 36484 - [- - -] # 6 Background long Completed 16 36462 - [- - -] # 7 Background short Completed 16 36436 - [- - -] # 8 Background short Completed 16 36412 - [- - -] # 9 Background long Completed 16 36404 - [- - -] #10 Background short Completed 16 36401 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes]

    Read the article

  • RHEL 5.x SCSI Driver .img update for initrd.img

    - by zmische
    I have production DB server (RHEL 5.1) with LSI Megaraid driver loaded during setup via DUD (Driver Upd Diskett). Now I'd like to update kernel and other packeges to 5.4 version. I also downloaded new LSI SCSI driver (megasr-13.11.0922.2009-1-rhel50-u4-all.img ). Could you explain the necessary steps to make this driver visible on boot for new kernel (lets assume, that I've already update kernel to 5.4)? I read the article on Redhat - "How do I add a driver to the initrd.img". Does it contain all the steps I need? Thanks in advance!

    Read the article

  • LSI RAID-on-chip with RAID6 over two SAS links goes red when HDD enclosure is powered cycled; how to recover?

    - by GregC
    I have a RAID6 array managed by LSI 9286-8e card. I also have Sans Digital 24-bay NexentaSTOR JBOD enclosure with SAS extender built-in. They are connected to separate UPS devices. Normally, I'd shut down the PC, leaving RAID6 in healthy state. But today the power to JBOD enclosure was cut but PC kept running. After restarting the PC, all disks in RAID6 have lit up RED, and the only option in LSI MegaRAID manager app was to reset each disk to unassigned, thereby loosing all data on RAID6 array. Thankfully, I am only testing, but how would I recover if this were to happen in production?

    Read the article

  • Simultaneous read/write to RAID array slows server to a crawl

    - by Jeff Leyser
    Fairly beefy NFS/SMB server (32GB RAM, 2 Xeon quad cores) with LSI MegaRAID 8888ELP controlling 12 drives configured into 3 different arrays. 5 2TB drives are grouped into a RAID 6 array. As expected, write performance to the array is slow. However, sustained, simultaneous read/write to the array (wether through NFS or done locally) seems to practically block any other access to anything else on the controller. For example, if I do: cp /home/joe/BigFile /home/joe/BigFileCopy where BigFile is 20G, then even a simple ls /home/jane will take many 10s of seconds to complete. In addition, an ls /backup will also take many tens of seconds, even though /backup is a different array on the same controller. As soon as the cp is done, everything is back to normal. cp /home/joe/BigFile /backup/BigFile does not exhibit this behavior. It's only when doing read/write to the same array.

    Read the article

  • CentOS - Add additional hard drive raid arrays on Dell Perc 5/i card

    - by Quanano
    We have a Dell Poweredge 2900 system with Dell Perc 5/i card and 4 SAS hard drives attached, with NTFS partitions on them. We installed CentOS on one raid array on this controller with a different controller and it is working fine. We are now trying to access the drives shown above and they are not being shown in /dev as sdb, etc. sda is the drive that we installed centos on and it has sda1, sda2, sda3, etc. The CDROM has been picked up as well. If I scan for scsi devices then the perc and adaptec controllers are both found. sg0 is the CDROM and sg2 is the centos installed, however I think sg1 is the other drive but I cannot see anyway to mount the partitions, as only the drive is listed in /dev. Thanks. EXTRA INFO fdisk -l: Disk /dev/sda: 72.7 GB, 72746008576 bytes 255 heads, 63 sectors/track, 8844 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x11e3119f Device Boot Start End Blocks Id System /dev/sda1 * 1 64 512000 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 64 8845 70528000 8e Linux LVM Disk /dev/mapper/vg_lal2server-lv_root: 34.4 GB, 34431041536 bytes 255 heads, 63 sectors/track, 4186 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_root doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_swap: 21.1 GB, 21139292160 bytes 255 heads, 63 sectors/track, 2570 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_swap doesn't contain a valid partition table Disk /dev/mapper/vg_lal2server-lv_home: 16.6 GB, 16647192576 bytes 255 heads, 63 sectors/track, 2023 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/vg_lal2server-lv_home doesn't contain a valid partition table These are all from the install hdd not the additional hard drives modprobe a320raid FATAL: Module a320raid not found. lsscsi -v: [0:0:0:0] cd/dvd TSSTcorp CDRWDVD TS-H492C DE02 /dev/sr0 dir: /sys/bus/scsi/devices/0:0:0:0 [/sys/devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0] [4:0:10:0] enclosu DP BACKPLANE 1.05 - dir: /sys/bus/scsi/devices/4:0:10:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:0:10/4:0:10:0] [4:2:0:0] disk DELL PERC 5/i 1.03 /dev/sda dir: /sys/bus/scsi/devices/4:2:0:0 [/sys/devices/pci0000:00/0000:00:05.0/0000:01:00.0/0000:02:0e.0/host4/target4:2:0/4:2:0:0] . lsmod: Module Size Used by fuse 66285 0 des_generic 16604 0 ecb 2209 0 md4 3461 0 nls_utf8 1455 0 cifs 278370 0 autofs4 26888 4 ipt_REJECT 2383 0 ip6t_REJECT 4628 2 nf_conntrack_ipv6 8748 2 nf_defrag_ipv6 12182 1 nf_conntrack_ipv6 xt_state 1492 2 nf_conntrack 79453 2 nf_conntrack_ipv6,xt_state ip6table_filter 2889 1 ip6_tables 19458 1 ip6table_filter ipv6 322029 31 ip6t_REJECT,nf_conntrack_ipv6,nf_defrag_ipv6 bnx2 79618 0 ses 6859 0 enclosure 8395 1 ses dcdbas 9219 0 serio_raw 4818 0 sg 30124 0 iTCO_wdt 13662 0 iTCO_vendor_support 3088 1 iTCO_wdt i5000_edac 8867 0 edac_core 46773 3 i5000_edac i5k_amb 5105 0 shpchp 33482 0 ext4 364410 3 mbcache 8144 1 ext4 jbd2 88738 1 ext4 sd_mod 39488 3 crc_t10dif 1541 1 sd_mod sr_mod 16228 0 cdrom 39771 1 sr_mod megaraid_sas 77090 2 aic79xx 129492 0 scsi_transport_spi 26151 1 aic79xx pata_acpi 3701 0 ata_generic 3837 0 ata_piix 22846 0 radeon 1023359 1 ttm 70328 1 radeon drm_kms_helper 33236 1 radeon drm 230675 3 radeon,ttm,drm_kms_helper i2c_algo_bit 5762 1 radeon i2c_core 31276 4 radeon,drm_kms_helper,drm,i2c_algo_bit dm_mirror 14101 0 dm_region_hash 12170 1 dm_mirror dm_log 10122 2 dm_mirror,dm_region_hash dm_mod 81500 11 dm_mirror,dm_log blkid: /dev/sda1: UUID="bc4777d9-ae2c-4c58-96ea-cedb342b8338" TYPE="ext4" /dev/sda2: UUID="j2wRZr-Mlko-QWBR-BndC-V2uN-vdhO-iKCuYu" TYPE="LVM2_member" /dev/mapper/vg_lal2server-lv_root: UUID="9238208a-1daf-4c3c-aa9b-469f0387ebee" TYPE="ext4" /dev/mapper/vg_lal2server-lv_swap: UUID="dbefb39c-5871-4bc9-b767-1ef18f12bd3d" TYPE="swap" /dev/mapper/vg_lal2server-lv_home: UUID="ec698993-08b7-443e-84f0-9f9cb31c5da8" TYPE="ext4" dmesg shows: megaraid_sas: fw state:c0000000 megasas: fwstate:c0000000, dis_OCR=0 scsi2 : LSI SAS based MegaRAID driver scsi 2:0:0:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:1:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:2:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:3:0: Direct-Access SEAGATE ST3146855SS S527 PQ: 0 ANSI: 5 scsi 2:0:4:0: Direct-Access HITACHI HUS154545VLS300 D590 PQ: 0 ANSI: 5 scsi 2:0:5:0: Direct-Access HITACHI HUS154545VLS300 D590 PQ: 0 ANSI: 5 scsi 2:0:8:0: Direct-Access FUJITSU MBA3073RC D305 PQ: 0 ANSI: 5 scsi 2:0:9:0: Direct-Access FUJITSU MBA3073RC D305 PQ: 0 ANSI: 5 i.e. the 3 RAID Arrays Seagate Hitatchi and Fujitsu hard drives respectively. FURTHER UPDATE I have installed the megaraid storage manager console and connected to the server. It appears that the two CentOS installation hard drives are OK. The other 6 drives, one raid array of 4 and one raid array of 2 disks. The other drives are listed as (Foreign) Unconfigured Good.

    Read the article

  • some questions about raid card

    - by cpps
    I have some questions about raid card. Use LSI MegaRAID® SAS 9260-8i raid card as a example. There is only two connection ports on the raid card, and they provide two cables that can connect 8 SAS/SATA storages. The document say it can connect "Maximum 32 drives per controller", I want to know how can I connect more than 8 hard disks with this card. Is that they say "Eight internal SATA+SAS ports" means they provide two cables which can connect 8 hard drives, but you can use other way to connect Maximum 32 drives? The other question. I see host bus adapter has raid integrated , so what is the difference between host bus adapter and raid card. Are they the same? I also know is SAS/SATA Expander's function only to connect more hard drives? Thanks in advance.

    Read the article

  • Bad Blocks Exist in Virtual Device PERC H700 Integrated

    - by neoX
    I have a DELL server with PERC H700 Integrated controller. I've made RAID5 with 12 harddrives and the virtual device is in Optimal state, but I receive such errors under linux: sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bd 98 00 00 00 08 00 00 end_request: I/O error, dev sda, sector 30640487832 sd 0:2:0:0: [sda] Unhandled error code sd 0:2:0:0: [sda] Result: hostbyte=0x07 driverbyte=0x00 sd 0:2:0:0: [sda] CDB: cdb[0]=0x88: 88 00 00 00 00 07 22 50 bc e0 00 00 01 00 00 00 end_request: I/O error, dev sda, sector 30640487648 But all disk are in Firmware state: Online, Spun Up. Also there is not a single ATA read or write error in any disk in the raid (I check them with smartctl -a -d sat+megaraid,N -H /dev/sda). The only strange thing is in the output in megacli: megacli -LDInfo -L0 -a0 ... Bad Blocks Exist: Yes How could there be bad blocks in a Virtual Drive, which is in optimal state and no disk is broken or even with a single error? I tried "Consistency Check", but it finished successfully and the errors are still in dmesg. Could Someone help me to figure it out what is wrong with my raid?

    Read the article

  • Windows Server 2008 R2 install reboots unexpectedly during "Completing installation" phase

    - by knda
    I am attempting to install Windows Server 2008 R2 onto a Cisco UCS C201 M2 rack mounted server but am having major difficulties and wondering if anyone has some insight or items they could recommend for me to look at to get this one resolved. Installation is being attempted via the Cisco remote console (using CIMC's Virtual dvd-rom).. following the first phase of Setup where the installation files are copied to the target hard drive, then a reboot occurs to load Setup from the HDD, mid-way in the "Completing Installation" phase the system then reboots unexpectedly. System configuration Cisco UCS C201 M2 (2RU rack mounted server) 16GB RAM, 2x 73GB 15K SAS, 4x 300GB 10k SAS Add-on cards - Intel quad-port GigE card (no fibre channel cards) Storage - LSI MegaRAID SAS 9261-8i. onboard SATA is disabled (no SATA drives connected) KVM - Belkin No physical DVD-ROM.. :( I have... Run memtest86+, no RAM faults Disabled/enabled SATA support (BIOS) Attempted install from USB DVD-ROM, no effect Attempted unattended install scripted via Cisco Configuration Manager DVD provided Removed Belkin KVM in case that was causing drama Discovered that the Cisco website is "awesome" for searching for PDFs/Drivers cough, reverted back to Google Downloaded latest LSI drivers from LSI's site and used during Server 2008 install checked Windows ISO against checksum's from MS site checked Windows ISO by using it for an install in a VM Running out of ways to troubleshoot this as I am not sure how to enable any sort of 'verbose' mode during the setup process. Next step I have planned is to remove the Intel NIC and try the installation again.. Edit: Problem was the "Cisco INTEL QUAD PT GBE" (1000/PT) .. will have to see if this card is faulty or if it's just drivers.. thanks for the help.

    Read the article

  • Server nearly unusable when doing disk writes

    - by Wikser
    My question closely relates to my last question here on serverfault. I was copying about 5GB from a 10 year old desktop computer to the server. The copy was done in Windows Explorer. In this situation I would assume the server to be bored by the dataflow. But as usual with this server, it really slowed down. At least I could work with the remote session, even there was some serious latency. The copy took its time (20min?). In this time I went to a colleague and he tried to log in in the same server via remote desktop (for some other reason). It took about a minute to get to the login screen, a minute to open the control panel, a minute to open the performance monitor, ... Icons were loading maybe one per second. We saw the following (from memory): CPU: 2% Avg. Queue Length: 50 Pages/sec: 115 (?) There was no other considerable activity on the server. The server seldom serves some ASP.NET pages, which became also very slow in this time. The relevant configuration is as follows: Windows 2003 SEAGATE ST3500631NS (7200 rpm, 500 GB) LSI MegaRAID based RAID 5 4 disks, 1 hot spare Write Through No read-ahead Direct Cache Mode Harddisk-Cache-Mode: off Is this normal behaviour for such a configuration? What measurements could give further clues? Is it reasonable to reduce the priority of such copy I/O and favour other processes like the remote desktop? How would you do that? Many thanks!

    Read the article