  • Out-of-the-Box Spatial Dashboards Improve Utility Outage Decisions

    - by stephen.garth
    Oracle Utilities Advanced Spatial Outage Analytics leverages the capabilities of Oracle Business Intelligence with map visualization and geospatial analysis of outage data from utility network management systems, providing BI dashboards to support utility executives and other decision makers throughout the enterprise. This excellent article by Oracle's Guerry Waters, published by Directions Media, gives details. Read the article here. Get more information: - Oracle Spatial - Oracle Utilities - Oracle Business Intelligence

    Read the article

  • What's the major outage you've been part of?

    - by Marco Ramos
    Outages are some of the things we try to avoid but they're inevitable: they happen (very rarely, we hope) and we have to know how to deal with them (and learn from them). So, what's the major outage you've been part of? How did you and your team deal with it? What have you learned for the future? Please share your thoughts :)

    Read the article

  • Can a registrar outage affect my website?

    - by Harry Muscle
    If my registrar has an outage and their servers go down for a while, will that affect my website. I'm not using any of my registrar hosting packages or name servers, I simply have a few domain names registered with them that point to my actual hosting provider. Based on my current understanding on how these things work I believe that an outage at my registrar will not affect my websites at all, but I'd like to hear this from someone with more experience in this field.

    Read the article

  • Microsoft Azure Outage

    The beginning of Azure's troubles was documented last Wednesday at approximately 1:45 a.m. GMT when its service management component malfunctioned. The initial message on the outage, posted by Microsoft on its Azure service dashboard, read: We are experiencing an issue with Windows Azure service management. Customers will not be able to carry out service management operations. Microsoft continued with its updates at 5 a.m. GMT, when it assured users that fewer than 3.8 percent of hosted services had been affected by the outage. The company also said it was doing its best to stop the issue ...

    Read the article

  • java.net outage

    - by alexismp
    The GlassFish website has been down for a number of hours (together with a number of other projects) as a result of a general outage in the java.net datacenter. The team is working hard on getting everything back to normal. You can track progress by following @ProjectKenai. Update: services should now all be back to normal. If you face java.net issues in the future, consider reporting them here. And now, back to work!

    Read the article

  • 10.04 wont boot after power outage

    - by Pat
    After unexpected power outage 10.04 won't boot, the following message appears mount: mounting /dev/disk/by-uuid/***************************** on /root failed: Invalid argument mount: mounting /sys on /root/sys failed: No such file or directory mount: mounting /dev on /root/dev failed: No such file or directory mount: mounting /sys on /root/sys failed: No such file or directory mount: mounting /proc on /root/proc failed: No such file or directory Target file system doesn't have /sbin/init No init found. Try passing init= bootarg Busybox v1.13.3 (Ubuntu 1:1.13.3-1ubuntu7) built-in shell (ash) Enter 'help' for a list of built-in commands (initramfs) _ I have tried rebooting from a liveCD but it wont boot and I cannot open a terminal to try to fix it by sudo fdisk -l as recommended on other posts. Any help would be greatly appreciated

    Read the article

  • after power outage, monitor won't turn on

    - by J82
    I had a power outage in my apartment today during a Windows 7 SP1 update. I installed SP1 and it told me to restart so I did and that's when the power outage happened. After the power came back on, I started the computer and it looks like the computer is running normally but my monitor is not getting a signal. I am using a Wacom Cintiq 21UX. I tried unplugging all the cords and plugs in the power strip and turning it back on. I also tried a strange method I read in another thread of removing the power cord, holding the on button for 30 seconds, putting the power cord back in, and turning it on. Still no dice. How can I get my monitor to turn on? please help..

    Read the article

  • Free Webinar Featuring Oracle Spatial and MapViewer, Oracle Business Intelligence, and Oracle Utilities

    - by stephen.garth
    Maps, BI and Network Management: Together At Last Date: Thursday, January 20 | Time: 11:00 a.m. PDT | 2:00 p.m. EDT | Duration: 1 hour Cost: FREE For years, utilities have wrestled with the challenge of providing executive management and other decision makers with maps and business intelligence during outages without compromising the performance of their real-time network operations and control systems. Join experts from Directions Media, Oracle and ThinkHuddle in this webinar for a discussion on how Oracle has addressed this challenge by incorporating Oracle Spatial data and the dashboard capabilities of Oracle Business Intelligence into a new application, Oracle Utilities Advanced Spatial Outage Analytics. Jim Steiner, Vice President of Spatial Product Management at Oracle, will provide an overview of Oracle's spatial and location technology, including Oracle Spatial 11g and Oracle Fusion Middleware MapViewer, and describe how Oracle is using this technology to spatially-enable many of its own enterprise applications. Brad Williams, Vice President of Oracle Utilities, will describe why and how the company developed Oracle Utilities Advanced Spatial Outage Analytics, how it works with Oracle Utilities Network Management System, and how this can deliver improved decision support and operational benefits to utilities. Steve Pierce, Spatial Systems Consultant with ThinkHuddle, will discuss architectural aspects and best practices in the integration of Oracle's spatial and BI technology. Following the presentation, attendees will have an opportunity to engage the panelists in a live Q&A session. Who Should Attend Executives, decision makers and analysts from IT, customer service, operations, engineering and marketing - especially in utilities, but also any business where location is important. Don't miss this webinar - Register Now. Find out more: Oracle Spatial on oracle.com More technical information on Oracle Technology Network Information on Oracle Utilities applications var gaJsHost = (("https:" == document.location.protocol) ? "https://ssl." : "http://www."); document.write(unescape("%3Cscript src='" + gaJsHost + "google-analytics.com/ga.js' type='text/javascript'%3E%3C/script%3E")); try { var pageTracker = _gat._getTracker("UA-13185312-1"); pageTracker._trackPageview(); } catch(err) {}

    Read the article

  • Computer does not switch on after power outage

    - by cristian
    VOLTAGE DROP OFF FOR PC does not restart The other day my pc was turned off due to power outage. Since that time the computer would not turn on again, no sign of life, it seems dead. I did several tests, changed the power outlet and disconnect the wires ... also I have reseated the cards ... but the result is that nothing changes. What can I do? Could there may be damage to the hardware due to the power outage? Note: the voltage drop is not due to a lightning storm and so is not due to damaged components (burnt card etc ...) Original Text: l'altro giorno il pc mi si è spento improvvisamente per calo tensione.... da quel momento non si è piu' riacceso...nessun segnale di vita...sembra proprio morto. Ho fatto diverse prove, cambio presa di alimentazione, scollegare i fili...insomma ho "mischiato le carte"...ma il risultato è che non cambia nulla. Cosa posso fare? cosa puo' essere successo? Possono esserci danni hardware per il calo di tensione? NB: il calo di tensione non e' dovuto ad una saetta e quindi escluderei danni causa temporale (bruciature scheda ecc...) Grazie mille

    Read the article

  • Computer making strange sound when turned on, ever since power outage

    - by Dot NET
    Recently we experienced a power outage, and the PC was off. However, once the power came back, I switched on the PC and heard a strange noise - almost as if the hard disk or fans were struggling to work. I can't really describe the sound, but it's a laboured, loud sound almost like a jack-hammer. This has been persisting ever since the power outage, however the noise stops after around 10 minutes or so, and doesn't start again until the computer is turned off and on again. At first I thought it had something to do with the HDD, but all my files are intact, chkdsk did not report any issues and performance is 100% unchanged, even in games (so the gfx card is fine, and so is the HDD most likely). My PC setup basically has around 3 cooling fans, but I'm not sure if it's one of these either as the noise actually stops after 10 minutes or so, and if I leave the PC on for 4 hours (for example) the noise never starts again. It's there solely when turning on the PC. I haven't got a UPS, and it's important to note that the computer was not on when the power went out - it was merely plugged in. I then promptly unplugged the PC once the power was out, and only plugged it in again when the power came back. Could it be the power supply? Unfortunately I can't open my tower as I would void the warranty. Are there any tests which I could carry out without voiding the warranty?

    Read the article

  • I had a power outage. Now MySQL's lock file won't go away. What do you suggest?

    - by jasonspiro
    I do freelance IT consulting for various clients, both in Toronto, Canada, and worldwide. A client recently experienced a power failure. Now they've been having various problems with a Slackware 12.0.0 machine which also acts as a DNS server. One problem is that they can't log into phpMyAdmin. I tried stopping and restarting MySQL. But even when MySQL is stopped, the lock file stays around. jasonspiro@cybertron:~$ sudo /etc/init.d/mysql stop Shutting down MySQL. SUCCESS! jasonspiro@cybertron:~$ sudo /etc/init.d/mysql stop ERROR! MySQL manager or server PID file could not be found! jasonspiro@cybertron:~$ sudo /etc/init.d/mysql status ERROR! MySQL is not running, but lock exists jasonspiro@cybertron:~$ ls -l /var/lock/subsys/mysql -rw-r--r-- 1 root root 0 2012-07-05 16:18 /var/lock/subsys/mysql Why is MySQL's lock file hanging around despite the fact that MySQL isn't running? Can I simply stop MySQL, delete the lock file, and start MySQL again? Are there any other steps that I should take next, or nothing?

    Read the article

  • Western Digital not recognized by Windows after power Outage on windows

    - by vikasde
    I have WD Essential Plus 1.5TB (formatted in NTFS). It was working fine under windows and mac mini. While it was connected to the mac mini, I had an power outage and now the HD is not being recognized under windows anymore. Now on the mac mini the HD is fine and I can see my data. When I use ActiveBootDisk under windows, then I can see the data as well. I updated the drivers on windows machine and also updated the firmware on the HD, but its still not being recognized. Is there any way for me to fix the HD under windows without having to re-format it?

    Read the article

  • Gmail outage only on one computer

    - by user123079
    Problem: Gmail (and only Gmail) quits working for a period of 5-10 mins only on one computer. Problem occurs several times daily Does not appear to be any "triggering event" - user is simply using Gmail normally when the problem arises User can access their Gmail from other computers on same LAN User can access all other sites, including other Google sites, from affected computer After several mins of outage, Gmail will spontaneously resume normal operation on affected computer The problem occurs in all browsers (Chrome, FF, Safari) Computer: MacBook Pro, OSX 10.7.3, latest browsers I find this very baffling. Any advice welcome.

    Read the article

  • Uptime concerns in case of AWS outage

    - by Aditya Patawari
    I am running an Elastic Load Balancer backup by 2 instances in different Availability Zones in US East. I am using Multi-AZ RDS as well. Ideally this should ensure that if one AZ goes down, it should not effect the app because everything is spread across multiple AZs. But the recent AWS outage took the app down for a long time. I am not sure how this can happen. It would be great if someone can point out what went wrong. Major question here I have is how can I avoid this in future? I can setup app servers across different regions or even providers and use DNS for load balancing but what do I do with MySQL? Read Replicas will introduce some lag which I would want to avoid.

    Read the article

  • Server can't set IP after power outage

    - by Ali
    The power went out all of a sudden and when we tried to restart everything when it came back on - our server can't be assigned an IP? We got an error stating that the IP for the server was already in use by another system. We then shut down all systems and restarted the server but then for some reason the server was assigned an IP but no one could connect to it - after restarting the server after setting it to have a dynamically assigned ip - the server now has no ip - just 0.0.0.0 - running an ipconfig/renew or ipconfig /release has no effect.. what should we do!!

    Read the article

  • Tomcat can't talk to MySql after outage

    - by gav
    I missed a payment for my server and hey suspended my account for a day or so. When they brought the server back up all my data was in tact but for some reason Tomcat can't make a JDBC connection to my MySql server. They both run on the same machine and hence I have a bind address of 127.0.0.1. It's strange because I have reset the machine of my own accord before without issue but clearly something has been reset in the downtime. I followed this guide (Just the bits which don't concern S3, I am not on Amazon infrastructure) originally and everything worked as expected. I'm very new to being a SysAdmin and I'm not sure what to try, how would you go about diagnosing this issue? The stack trace I get is as follows; INFO: Deploying web application archive myapp-1.1.war 2010-05-26 22:07:22,221 [main] ERROR context.ContextLoader - Context initialization failed org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'messageSource': Initialization of bean failed; nested exception is org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'transactionManager': Cannot resolve reference to bean 'sessionFactory' while setting bean property 'sessionFactory'; nested exception is org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'sessionFactory': Cannot resolve reference to bean 'hibernateProperties' while setting bean property 'hibernateProperties'; nested exception is org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'hibernateProperties': Cannot resolve reference to bean 'dialectDetector' while setting bean property 'properties' with key [hibernate.dialect]; nested exception is org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'dialectDetector': Invocation of init method failed; nested exception is org.springframework.jdbc.support.MetaDataAccessException: Could not get Connection for extracting meta data; nested exception is org.springframework.jdbc.CannotGetJdbcConnectionException: Could not get JDBC Connection; nested exception is org.apache.commons.dbcp.SQLNestedException: Cannot create PoolableConnectionFactory (Communications link failure The last packet sent successfully to the server was 0 milliseconds ago. The driver has not received any packets from the server.) at org.springframework.beans.factory.support.AbstractAutowireCapableBeanFactory.doCreateBean(AbstractAutowireCapableBeanFactory.java:519) at org.codehaus.groovy.grails.commons.spring.ReloadAwareAutowireCapableBeanFactory.doCreateBean(ReloadAwareAutowireCapableBeanFactory.java:129) at org.springframework.beans.factory.support.AbstractAutowireCapableBeanFactory.createBean(AbstractAutowireCapableBeanFactory.java:450) at org.springframework.beans.factory.support.AbstractBeanFactory$1.getObject(AbstractBeanFactory.java:290) at org.springframework.beans.factory.support.DefaultSingletonBeanRegistry.getSingleton(DefaultSingletonBeanRegistry.java:222) at org.springframework.beans.factory.support.AbstractBeanFactory.doGetBean(AbstractBeanFactory.java:287) at org.springframework.beans.factory.support.AbstractBeanFactory.getBean(AbstractBeanFactory.java:193) at org.springframework.context.support.AbstractApplicationContext.initMessageSource(AbstractApplicationContext.java:714) at org.springframework.context.support.AbstractApplicationContext.refresh(AbstractApplicationContext.java:404) at org.codehaus.groovy.grails.commons.spring.GrailsWebApplicationContext.refresh(GrailsWebApplicationContext.java:153) ... I get this error for a number of 'beans'. If I type mysql at my command prompt then I can easily login with the same credentials as my grails app which uses GORM and Hibernate to persist objects to the DB. I might not have given enough info to start with but I'm really interested to learn and will certainly provide it if asked, I just really don't know where to start on this one. Thanks, Gav

    Read the article

  • Computer wont POST after power outage

    - by aaron
    I had just turned my computer on and windows was loading when the power in my neighborhood went out. Normally, when I turn my computer on, the video card fan spins up, then slows down, POST and windows boots. Now, after the blackout, the video card fan spins fast and wont stop. Nothing is displayed on the monitor. The monitor does not detect that the video card is sending it signals, it just stays on standby. No POST or beep codes. This is what I have tried so far: My motherboard has 2 PCI express slots and I tried plugging the video card into both of them but that didn't fix anything. I have replaced the power supply, that didn't fix anything. I cleared the CMOS, that didn't fix anything. Does anyone have any idea of what could be wrong? Thanks!

    Read the article

  • Power outage, Server 2K3 remains on "applying computer settings"

    - by syuroff
    My reward for clicking the "test" button in the APC UPS software was that it completely cut the power to my SQL server. The server promptly rebooted, the SQL service is running (verified by the app on another server that queries it), but the GUI has remained on "applying computer settings" for 20 minutes and counting, and it forbids RDC connections. Since SQL is up, it is fulfilling its key role, but it's obviously not right. What step to take next? Wait longer? Hardware is a Dell Poweredge 2850, internal RAID10.

    Read the article

  • Network outage caused by SMC8013WG Cable Modem/Router ?

    - by mkocubinski
    At work, we have a basic Class C Network. The gateway/router is a SMC8013WG (stock comcast commercial cable modem), and simple unmanaged switch (HP Pro Curve 1400 24G). The SMC8013WG is our default gateway as well as DHCP server. Periodically, I'd say almost every other day.. the entire network will just stop responding. I won't be able to ping/see the gateway, any computers on our local network, or anything on the internet. The only way to fix this is to unplug the Comcast cable modem, wait, and plug back in. This unfailingly fixes the problem. But this doesn't make much sense to me.. shouldn't the network still be fine locally, since everything is plugged into the switch anyway? Why would resetting the router fix this? Can anyone suggest anything to check to in order to narrow this problem down? Just to be clear.. here is the basic topology: { Internet } -- (12.345.67.89) Comcast Cable Modem (192.168.1.1) -- Switch -- 192.168.1.2-254 P.S. Our IT guy is in about 3 hours a day every other week or so, so.. we're kind of on our own most of the time.

    Read the article

  • Cisco 851 (IOS) router: FastEthernet 4 (WAN) got the shutdown flag.

    - by cjavapro
    At a customer location there was a Cisco 851 router (which uses IOS). The PCs on location were all of a sudden unable to connect. We came on site and found that FastEthernet 4 (the WAN port) was "administratively down". We ran these commands to resolve it config t interface fa4 no shutdown exit exit write Now the mystery is how the shutdown flag got there in the first place? The router was on battery backup... but during the outage it was power cycled by the customer. It is possible that there was a short outage by the ISP and that the power cycle caused the shutdown flag to come up. There may have been a hack or an attack pattern that caused the shutdown flag to come up. There may have been a hack or an attack pattern that the router to become unavailable and then caused the shutdown flag to be added on startup. Question: Does anybody have any clues? or at least remember that they had a shutdown flag come up on their WAN port also?

    Read the article

  • Losing internet connectivity on server after installing LogMeIn Hamachi (with server set as gateway node)

    - by Kim Jong-Un
    Our domain controller (SBS 2003) completely lost internet and network connectivity yesterday after I remotely installed LogMeIn Hamachi on it and set it to be a gateway node- in an attempt to create a VPN link between the server and a remote site. I had to go in to the office to resolve the problem as, unsurprisingly, my own remote access to the server was also lost. I was only able to restore network connectivity by deleting a virtual network adapter Hamachi created when making the server the gateway node (called "Hamachi bridge" I believe), then rebooting the server. This is a repeatable problem. Every time I try to get this to work, it just takes the server offline. Why would this bridge affect regular TCP/IP connectivity on the NIC in this way? I have tried a "hub-and-spoke" configuration between the server and our PC at a remote site (server set as hub, remote site as spoke). This caused no such problems with general internet connectivity, and file transfer worked well between the two computers. However, there was a DNS issue with the VPN between the two sites- resulting in Active Directory not being able to communicate between them (could not log on using domain user accounts at remote site if they were not already cached on that machine). I only tried a "gateway" network as LogMeIn support told me: If you can get the Active Directory to work it would only be through a "Gateway" network type with the server acting as the Gateway Node. You would configure the gateway settings on the server in the Hamachi client on that machine to push whatever IP's/DNS settings you prefer and at that point AD would be able (all things being equal) communicate to the client node when it attaches. We do not have any ActiveDirectory configuration info as that's outside the scope of our support. I hope this helps. It would be fantastic if I could get Active Directory to work over a Hamachi VPN connection, without worrying about the server going offline in this way. Does anyone have any ideas how I should proceed, or any theories as to what is going on when I try to use the "gateway" network type? I want to try to narrow down what is going on here.

    Read the article

  • IP Micro-outages, telephone micro-outages, and CATV micro-outages

    - by Michael Graff
    This is a long and complicated question, mostly because it has been going on for 2.5 years without a solution in sight. It also is only one-third computer related, the other two-thirds are cable TV and cable-phone related. Background I have COX Communications for a cable provider, and we get Internet, digital cable TV, and digital phone service through them. The Internet is a SB5101 right now, and has been a DPC2100 and SB5120 in the past. Same results. The phone service is provided through a telephone interface mounted on the outside of the house (not classic VoIP) and the CATV is through a Scientific Atlanta receiver without DVR. I do have a TiVo connected to the CATV box. Symptoms The CATV shows "blocking" -- sometimes very very short duration where a few blocks appear on the screen. Sometimes it lasts long enough that the video "pauses" for 2-5 seconds, and rarely but not unseen the audio also fails. The CATV decoder box shows no correctable (FEC) or uncorrectable errors. That is, all BER counters are zero for the video stream. The Internet shows "micro-outages" where it appears that sent packets are not making it out, but I continue to receive packets from local modems. That is, pings stop coming back, but I continue to see modems broadcast for DHCP, and sometimes they ask more than once. The cable modem shows no errors during this time, but cable modems lie like you would not believe. It is actually possible to unplug the coax from the modem for 20 seconds and it reports NO ERRORS to the provider's tools. The phone service cuts out for 1-3 seconds, infrequently. When this happens, I hear NOTHING (not even comfort noise) and the remote side hears a "click" as if I were getting a call waiting message. However, there is no call incoming, other than the one I'm currently on of course. Things SEEM to happen more frequently when the temperature outside swings from cold to warm, so fall/spring seems worse than summer/winter. All micro-outages occur between once or twice a day (which I could ignore) to 10 times per hour. All SNR, signal levels, noise levels, etc. show very close to optimal when measured. COX's diagnosis This is a continual pain for me. Over the last 2.5 years, they have opened, "fixed" something, and closed the tickets. They close it without confirming that it is indeed better, and when I reopen they cannot do that, but instead they open a new ticket and send yet another low-level tech out to do the same signal tests and report that all is OK. I've finally gotten a line tech who has a clue and is motivated enough to pursue this with me. We have tried things like switching the local nodes over to UPS and generator power, but this does not trigger the noise. We have tried replacing all cabling, the tap outside my house, the modem, the CATV decoder -- all without resolution. Recently they have decided it is both my computer or switch, my TiVo, and my phone that are all broken and causing this issue. My debugging steps I spent the worse day of my TV-watching life yesterday and part of today. I watched live TV without the TiVo. I witnessed blocking, but it did "feel different." and was actually more severe. Some days it is better, some days it is worse, so perhaps this was just a very bad day. Today, I connected the TiVo to my DVD player, and ran two very long movies through it. I saw no blocking at all during nearly 6 hours of video. Suggestions? Does anyone have any suggestions on what to do next? I understand perhaps only the IP side can be addressed here, but it is one of the more limiting debugging options.

    Read the article

  • BES 5.x issues when connecting to Exchange 2010 SP2 RU4

    - by makerofthings7
    Ever since we updated from SP1 RU4 to SP2 RU4 we have noticed that our BES devices will simply stop receiving email. This has occurred at least 5 times in the past few weeks. Today, while speaking with RIM support (a T3 contract), they said that they have reports of sporadic connectivity issues from some BES users. This has been occurring with Exchange 2010 SP2 RU4, and have no public information to give us. We were able to temporarily get things running by doing any or all of the following Restart the BES server Recreate the MAPI profile (deleted the keys in the registry) Restart the CAS servers Wait it out (2 hours) What other options should I take to resolve this issue?

    Read the article

  • Power outage during disk wipe. What do I do now?

    - by Mark Trexler
    I was using Roadkil Diskwipe on an external hard drive and the power went out. I had removed it from any outlet connection by the time power was restored to prevent power-spike damage (it's on a surge protector, but I didn't want to rely on that). My question is, where do I go from here? Obviously I don't care about preserving any data currently on it, I just want to make sure the drive itself is not terminally damaged. I'm running chkdsk (full), but I don't know if that's the correct step to assessing any damage. If it makes any difference, the hard drive was unallocated at the time of the outage, as Diskwipe requires that for it to run. Also, could something like this cause latent problems with the drive itself (i.e. serious issues that I won't be aware of when testing it now). I'd appreciate any program recommendations if chkdsk is not the most appropriate diagnostic route. Thank you.