  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Hi! Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Incredble low disk performance on HP DL385 G7

    - by 3molo
    Hi, As a test of the Opteron processor family, I bought a HP DL385 G7 6128 with HP Smart Array P410i Controller - no memory. The machine has 20GB ram 2x146GB 15k rpm SAS + 2x250GB SATA2, both in Raid 1 configurations. I run Vmware ESXi 4.1. Problem: Even with one virtual machine only, tried Linux 2.6/Windows server 2008/Windows 7, the VMs' feel really sluggish. With windows 7, the vmware converter installation even timed out. Tried both SATA and SAS disks and SATA disks are nearly unsusable, while SAS disks feels extremely slow.I can't see a lot of disk activity in the infrastructure client, but I haven't been looking for causes or even tried diagnostics because I have a feeling that it's either because of the cheap raid controller - or simply because of the lack of memory for it. Despite the problems, I continued and installed a virtual machine that serves a key function, so it's not easy to take it down and run diagnostics. Would very much like to know what you guys have to say of it, is it more likely to be a problem with the controller/disks or is it low performance because of budget components? Thanks in advance,

    Read the article

  • Can I use a Smart Array P410 controller on a HP Proliant DL 180 G5 server?

    - by Massimo
    This link says the HP Proliant DL 180 G5 server only supports Smart Array E200, E500, P400 and P800 controllers. Can I use a Smart Array P410 instead? Currently the server has only the default internal controller, I need an additional one for better performance and to support additional drives (the default controller only supports 4, with a Smart Array controller all 8 bays can be used). The disks are SATA ones.

    Read the article

  • HP DL180 G6 P410 8x SATA 1TB, what is the optimal configuration?

    - by Oneiroi
    I have a HP DL180 G6 with a P410 raid controller. Presently this runs using 4x 1TB Samsung Spinpoint SATA drives, in a RAID10 configuration using default settings. I am about to add a backplane to increase the drive capacity from 4 to 12 drives, and I plan to install 4 more 1TB SATA Drives. The drives are matched and have close serial numbers (They arrived together in the Manufacturers pallet). Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s I will also be installing RHEL 6.1 x86_64. My question is what would be the optimal RAID settings (stripe etc.) for this configuration? To recap: 8x Model HD103UJ 1000GB/7200rpm/32M Rated for 3GB/s RAID 10 configuration. Thanks in advance. Update for role: Server is to become an iscsi target for an internal openstack deployment currently underway. (Glance) Will also provide virtualisation through KVM

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • hp smart array lock up code 0x15, what is that? (or where can I get a list of descriptions of HP smart array controller lock up codes)

    - by user47650
    Hi, I've had a couple of Dl180 6g boxes hung over the last week, each have a P410 smart array controller. upon reboot the server has indicated that a controller failure event occurred and the previous lock up code was 0x15 - the server rebooted without issue. However there was nothing in the IML log, but the ADU report provided the following; Trap Address High Or Post Results Lockup Reason Or Post Error RIS Updates Or Post Error Detail Firmware Version Trap Address Low 0x8087 0x0015 0x0000033e 0x015e 0xd65c any suggestions on what that code is, my google fu failed. And hp support have not responded with any detail as yet.

    Read the article

  • PostgreSQL server: 10k RPM SAS or Intel 520 Series SSD drives?

    - by Vlad
    We will be expanding the storage for a PostgreSQL server and one of the things we are considering is using SSDs (Intel 520 Series) instead of rotating discs (10k RPM). Price per GB is comparable and we expect improved performance, however we are concerned about longevity since our database usage pattern is quite write-heavy. We are also concerned about data corruption in case of power failure (due to SSDs write cache not flushing properly). We currently use RAID10 with 4 active HDDs (10k 146GB) and 1 spare configured in the controller. It's a HP DL380 G6 server with P410 Smart Array Controller and BBWC. What makes more sense: upgrading the drives to 300GB 10k RPM or using Intel 520 Series SSDs (240GB)?

    Read the article

  • Different block sizes for partition and underlying logical disk on HP Raid Controller (Linux)

    - by Wawrzek
    Following links collected in this thread I started to check blockdev and found the following output indicating different sizes for partition c0d9p1 and the underlying device (c0d9): [root@machine ~]# blockdev --report /dev/cciss/c0d9 RO RA SSZ BSZ StartSec Size Device rw 256 512 4096 0 3906963632 /dev/cciss/c0d9 [root@machine ~]# blockdev --report /dev/cciss/c0d9p1 RO RA SSZ BSZ StartSec Size Device rw 256 512 2048 1 3906959039 /dev/cciss/c0d9p1 We have a lot of small files, so yes the block size is smaller than normal. The device is a logical driver on an HP P410 raid controller, simple disk without any raid - RAID 0 on one disk to be precise. (Please note that above configuration is a feature not a bug). Therefore, I have the following questions. Can the above discrepancy in the block size affect disk performance? Can I control the block size using hpacucli?

    Read the article

  • Windows backups to VM Esxi

    - by Martyn
    I'm very new to ESXi, so apologies if this is a silly question. I have ESXi 5.1 running running on HP Proliant Microserver with internal LUNs RAIDed with HP P410 Smart Array card. I have 2 Windows Server 2012 VMs running as Domain controllers. These are being backed-up up with GhettoVCB to a dedicated datastore hosted on LUNs on a eSata external device. I have several Windows 8 & 7 PC's connected to this domain. I want to back up these Windows PCs, via the built in backup software, ideally to the external eSata device as well. What do I need to do to have the Windows PC's see the datastore? I assume I could create a VM for FreeNas or something, or share out the datastore via one of the Windows Server 2012 VMs. Both those options seem a little bit of an over kill?

    Read the article

  • Four disks - RAID 10 or two mirrored pairs?

    - by ewwhite
    I have this discussion with developers quite often. The context is an application running in Linux that has a medium amount of disk I/O. The servers are HP ProLiant DL3x0 G6 with four disks of equal size @ 15k rpm, backed with a P410 controller and 512MB of battery or flash-based cache. There are two schools of thought here, and I wanted some feedback... 1). I'm of the mind that it makes sense to create an array containing all four disks set up in a RAID 10 (1+0) and partition as necessary. This gives the greatest headroom for growth, has the benefit of leveraging the higher spindle count and better fault-tolerance without degradation. 2). The developers think that it's better to have multiple RAID 1 pairs. One for the OS and one for the application data, citing that the spindle separation would reduce resource contention. However, this limits throughput by halving the number of drives and in this case, the OS doesn't really do much other than regular system logging. Additionally, the fact that we have the battery RAID cache and substantial RAM seems to negate the impact of disk latency... What are your thoughts?

    Read the article

  • Linux - real-world hardware RAID controller tuning (scsi and cciss)

    - by ewwhite
    Most of the Linux systems I manage feature hardware RAID controllers (mostly HP Smart Array). They're all running RHEL or CentOS. I'm looking for real-world tunables to help optimize performance for setups that incorporate hardware RAID controllers with SAS disks (Smart Array, Perc, LSI, etc.) and battery-backed or flash-backed cache. Assume RAID 1+0 and multiple spindles (4+ disks). I spend a considerable amount of time tuning Linux network settings for low-latency and financial trading applications. But many of those options are well-documented (changing send/receive buffers, modifying TCP window settings, etc.). What are engineers doing on the storage side? Historically, I've made changes to the I/O scheduling elevator, recently opting for the deadline and noop schedulers to improve performance within my applications. As RHEL versions have progressed, I've also noticed that the compiled-in defaults for SCSI and CCISS block devices have changed as well. This has had an impact on the recommended storage subsystem settings over time. However, it's been awhile since I've seen any clear recommendations. And I know that the OS defaults aren't optimal. For example, it seems that the default read-ahead buffer of 128kb is extremely small for a deployment on server-class hardware. The following articles explore the performance impact of changing read-ahead cache and nr_requests values on the block queues. http://zackreed.me/articles/54-hp-smart-array-p410-controller-tuning http://www.overclock.net/t/515068/tuning-a-hp-smart-array-p400-with-linux-why-tuning-really-matters http://yoshinorimatsunobu.blogspot.com/2009/04/linux-io-scheduler-queue-size-and.html For example, these are suggested changes for an HP Smart Array RAID controller: echo "noop" > /sys/block/cciss\!c0d0/queue/scheduler blockdev --setra 65536 /dev/cciss/c0d0 echo 512 > /sys/block/cciss\!c0d0/queue/nr_requests echo 2048 > /sys/block/cciss\!c0d0/queue/read_ahead_kb What else can be reliably tuned to improve storage performance? I'm specifically looking for sysctl and sysfs options in production scenarios.

    Read the article