Search Results

Search found 2329 results on 94 pages for 'minute'.

Page 10/94 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • Displaying timecode using NSTimer and NSDateFormatter

    - by Chris B
    Hi. I am very close to completing my first iphone app and it has been a joy. I am trying to add running timecode using the current time via an NSTimer displaying the current time (NSDate) on a UILabel. NSDate is working fine for me, showing hour, minute, second, milliseconds. But instead of milliseconds, I need to show 24 frames per second. The problem is that I need the frames per second to be synced 100% with the hour, minute and second, so I can't add the frames in a separate timer. I tried that and had it working but the frame timer was not running in sync with the date timer. Can anyone help me out with this? Is there a way to customize NSDateFormatter so that I can have a date timer formatted with 24 frames per second? Right now I'm limited to formatting just hours, minutes, seconds, and milliseconds. Here's the code I'm using right now -(void)runTimer { // This starts the timer which fires the displayCount method every 0.01 seconds runTimer = [NSTimer scheduledTimerWithTimeInterval: .01 target: self selector: @selector(displayCount) userInfo: nil repeats: YES]; } //This formats the timer using the current date and sets text on UILabels - (void)displayCount; { NSDateFormatter *formatter = [[[NSDateFormatter alloc] init] autorelease]; NSDate *date = [NSDate date]; // This will produce a time that looks like "12:15:07:75" using 4 separate labels // I could also have this on just one label but for now they are separated // This sets the Hour Label and formats it in hours [formatter setDateFormat:@"HH"]; [timecodeHourLabel setText:[formatter stringFromDate:date]]; // This sets the Minute Label and formats it in minutes [formatter setDateFormat:@"mm"]; [timecodeMinuteLabel setText:[formatter stringFromDate:date]]; // This sets the Second Label and formats it in seconds [formatter setDateFormat:@"ss"]; [timecodeSecondLabel setText:[formatter stringFromDate:date]]; //This sets the Frame Label and formats it in milliseconds //I need this to be 24 frames per second [formatter setDateFormat:@"SS"]; [timecodeFrameLabel setText:[formatter stringFromDate:date]]; }

    Read the article

  • Keeping values on form after submition

    - by Lina
    Hi, I'm trying to keep the entered data in the form after submitting by using "value=..." I'm getting a compilation error on the following code: <form id="myform"> <input id="hour" type="text" name="hour" value="<%=hour%>" style="width:30px; text-align:center;" /> : <input id="minute" type="text" name="minute" value="<%=minute%>" style="width:30px; text-align:center;" /> <br/> <input type="submit" value="Validate!" /> </form> the error is : Description: An error occurred during the compilation of a resource required to service this request. Please review the following specific error details and modify your source code appropriately. Compiler Error Message: CS0103: The name 'hour' does not exist in the current context any solution? thanks a lot in advance, Lina

    Read the article

  • Which tools to use and how to find file descriptors leaking from Glassfish?

    - by cclark
    We release new code to production every week and Glassfish hasn't had any problems. This weekend we had to move racks at our hosting provider. There were not any code changes (they just powered off, moved, re-racked and powered on) but we're on a new network infrastructure and suddenly we're leaking file descriptors like a sieve. So I'm guessing there is some sort of connection attempting to be made which now fails due to a network change. I'm running Glassfish v2ur2-b04/AS9.1_02 on RHEL4 with an embedded IMQ instance. After the move I started seeing: [#|2010-04-25T05:34:02.783+0000|SEVERE|sun-appserver9.1|javax.enterprise.system.container.web|_ThreadID=33;_ThreadName=SelectorThread-?4848;_RequestID=c4de6f6d-c1d6-416d-ac6e-49750b1a36ff;|WEB0756: Caught exception during HTTP processing. java.io.IOException: Too many open files at sun.nio.ch.ServerSocketChannelImpl.accept0(Native Method) ... [#|2010-04-25T05:34:03.327+0000|WARNING|sun-appserver9.1|javax.enterprise.system.stream.err|_ThreadID=34;_ThreadName=Timer-1;_RequestID=d27e1b94-d359-4d90-a6e3-c7ec49a0f383;|java.lang.NullPointerException at com.sun.jbi.management.system.AutoAdminTask.pollAutoDirectory(AutoAdminTask.java:1031) Using lsof I check the number of file descriptors and I see quite a few entries which look like: java 18510 root 8556u sock 0,4 1555182 can't identify protocol java 18510 root 8557u sock 0,4 1555320 can't identify protocol java 18510 root 8558u sock 0,4 1555736 can't identify protocol java 18510 root 8559u sock 0,4 1555883 can't identify protocol If I do a count of open file descriptors every minute I see it growing by 12 every minute. I have no idea what these sockets are. I've undeployed my application so there is only a plain Glassfish instance running and I still see it leaking 12 file descriptors a minute. So I think this leak is in Glassfish or potentially IMQ. What approach should I take to tracking down these sockets of unknown protocol? What tools can I use (or flags can I pass to lsof) to get more information about where to look? thanks, chuck

    Read the article

  • Add dynamic charts using ASP.NET CHART CONTROL, c#

    - by dhareni
    I wanted to add dynamic charts in the webpage. It goes like this... I get the start and end date from user and draw separate charts for each date bewteen the start and end date. I get the data from sql database and bind it with the chart like this: SqlConnection UsageLogConn = new SqlConnection(ConfigurationManager.ConnectionStrings["UsageConn"].ConnectionString); UsageLogConn.Open();//open connection string sql = "SELECT v.interval,dateadd(mi,(v.interval-1)*2,'" + startdate + " 00:00:00') as 'intervaltime',COUNT(Datediff(minute,'" + startdate + " 00:00:00',d.DateTime)/2) AS Total FROM usage_internet_intervals v left outer join (select * from Usage_Internet where " + name + " LIKE ('%" + value + "%') and DateTime BETWEEN '" + startdate + " 00:00:00' AND '" + enddate + " 23:59:59') d on v.interval = Datediff(minute,'" + startdate + " 00:00:00',d.DateTime)/2 GROUP BY v.interval,Datediff(minute,'" + startdate + " 00:00:00',d.DateTime)/2 ORDER BY Interval"; SqlCommand cmd = new SqlCommand(sql, UsageLogConn); SqlDataAdapter mySQLadapter = new SqlDataAdapter(cmd); Chart1.DataSource = cmd; // set series members names for the X and Y values Chart1.Series["Series 1"].XValueMember = "intervaltime"; Chart1.Series["Series 1"].YValueMembers = "Total"; UsageLogConn.Close(); // data bind to the selected data source Chart1.DataBind(); cmd.Dispose(); The above code adds only one chart for one date and I have added 'chart1' to design view and its not created dynamic. But I wanted to add more charts dynamic at runtime to the webpage. Can anyone help me with this? I am using VS 2008, ASP.NET 3.5 and the charting lib is: using System.Web.UI.DataVisualization.Charting;

    Read the article

  • Why aren't my MySQL Group By Hours vs Half Hours files Not displaying same data?

    - by stogdilla
    I need to be able to display data that I have in 15 minute increments in different display types. I have two queries that are giving me trouble. One shows data by half an hour, the other shows data by hour. The only issue is that the data totals change between queries. It's not counting the data that happens between the time frames, only AT the time frames. Ex: There are 5 things that happen at 7:15am. 2 that happen at 7:30am and 4 that show at 7:00am. The 15 minute view displays all of the data. The half hour view displays the data from 7:00am and from 7:30am but ignores the 7:15am. The hour display only shows the 7:00am data Here are my queries: $query="SELECT * FROM data WHERE startDate='$startDate' and queue='$queue' GROUP BY HOUR(start),floor(minute(start)/30)"; and $query="SELECT * FROM data WHERE startDate='$startDate' and queue='$queue' GROUP BY HOUR(start) "; How can I pull out the data in groups like I have but get all the data included? Is the issue the way the data is stored in the mysql table? Currently I have a column with dates (2010-03-29) and a column with times (00:00) Do I need to convert these into something else?

    Read the article

  • Add leading zeros to this javascript countdown script?

    - by eddjedi
    I am using the following countdown script which works great, but I can't figure out how to add leading zeros to the numbers (eg so it displays 09 instead of 9.) Can anybody help me out please? Here's the current script: function countDown(id, end, cur){ this.container = document.getElementById(id); this.endDate = new Date(end); this.curDate = new Date(cur); var context = this; var formatResults = function(day, hour, minute, second){ var displayString = [ '<div class="stat statBig">',day,'</div>', '<div class="stat statBig">',hour,'</div>', '<div class="stat statBig">',minute,'</div>', '<div class="stat statBig">',second,'</div>' ]; return displayString.join(""); } var update = function(){ context.curDate.setSeconds(context.curDate.getSeconds()+1); var timediff = (context.endDate-context.curDate)/1000; // Check if timer expired: if (timediff<0){ return context.container.innerHTML = formatResults(0,0,0,0); } var oneMinute=60; //minute unit in seconds var oneHour=60*60; //hour unit in seconds var oneDay=60*60*24; //day unit in seconds var dayfield=Math.floor(timediff/oneDay); var hourfield=Math.floor((timediff-dayfield*oneDay)/oneHour); var minutefield=Math.floor((timediff-dayfield*oneDay-hourfield*oneHour)/oneMinute); var secondfield=Math.floor((timediff-dayfield*oneDay-hourfield*oneHour-minutefield*oneMinute)); context.container.innerHTML = formatResults(dayfield, hourfield, minutefield, secondfield); // Call recursively setTimeout(update, 1000); }; // Call the recursive loop update(); }

    Read the article

  • Using stringstream instead of `sscanf` to parse a fixed-format string

    - by John Dibling
    I would like to use the facilities provided by stringstream to extract values from a fixed-format string as a type-safe alternative to sscanf. How can I do this? Consider the following specific use case. I have a std::string in the following fixed format: YYYYMMDDHHMMSSmmm Where: YYYY = 4 digits representing the year MM = 2 digits representing the month ('0' padded to 2 characters) DD = 2 digits representing the day ('0' padded to 2 characters) HH = 2 digits representing the hour ('0' padded to 2 characters) MM = 2 digits representing the minute ('0' padded to 2 characters) SS = 2 digits representing the second ('0' padded to 2 characters) mmm = 3 digits representing the milliseconds ('0' padded to 3 characters) Previously I was doing something along these lines: string s = "20101220110651184"; unsigned year = 0, month = 0, day = 0, hour = 0, minute = 0, second = 0, milli = 0; sscanf(s.c_str(), "%4u%2u%2u%2u%2u%2u%3u", &year, &month, &day, &hour, &minute, &second, &milli ); The width values are magic numbers, and that's ok. I'd like to use streams to extract these values and convert them to unsigneds in the interest of type safety. But when I try this: stringstream ss; ss << "20101220110651184"; ss >> setw(4) >> year; year retains the value 0. It should be 2010. How do I do what I'm trying to do? I can't use Boost or any other 3rd party library, nor can I use C++0x.

    Read the article

  • How do I break down an NSTimeInterval into year, months, days, hours, minutes and seconds on iPhone?

    - by willc2
    I have a time interval that spans years and I want all the time components from year down to seconds. My first thought is to integer divide the time interval by seconds in a year, subtract that from a running total of seconds, divide that by seconds in a month, subtract that from the running total and so on. That just seems convoluted and I've read that whenever you are doing something that looks convoluted, there is probably a built-in method. Is there? I integrated Alex's 2nd method into my code. It's in a method called by a UIDatePicker in my interface. NSDate *now = [NSDate date]; NSDate *then = self.datePicker.date; NSTimeInterval howLong = [now timeIntervalSinceDate:then]; NSDate *date = [NSDate dateWithTimeIntervalSince1970:howLong]; NSString *dateStr = [date description]; const char *dateStrPtr = [dateStr UTF8String]; int year, month, day, hour, minute, sec; sscanf(dateStrPtr, "%d-%d-%d %d:%d:%d", &year, &month, &day, &hour, &minute, &sec); year -= 1970; NSLog(@"%d years\n%d months\n%d days\n%d hours\n%d minutes\n%d seconds", year, month, day, hour, minute, sec); When I set the date picker to a date 1 year and 1 day in the past, I get: 1 years 1 months 1 days 16 hours 0 minutes 20 seconds which is 1 month and 16 hours off. If I set the date picker to 1 day in the past, I am off by the same amount. Update: I have an app that calculates your age in years, given your birthday (set from a UIDatePicker), yet it was often off. This proves there was an inaccuracy, but I can't figure out where it comes from, can you?

    Read the article

  • How to display buttons after enterframe event is over in Corona?

    - by user1463542
    I am trying to display two buttons called countd_again and main_menu after my enterframe event is over. I can't see those buttons after enterframe event is over,though. Can you check my code,please? And also i want to add new addListener for the buttons using director and scene. module(..., package.seeall) function new() local localGroup = display.newGroup(); display.setStatusBar(display.HiddenStatusBar) local background = display.newImage("background.png") start=os.time() cnt=1 local countd_again = display.newImage("yeniden.png") countd_again.x=100 countd_again.y=100 countd_again.isVisible= false; countd_again.alpha=0; countd_again.scene="helloWorld"; local main_menu= display.newImage("anamenu.png") main_menu.x=100 main_menu.y=300 main_menu.isVisible=false; main_menu.alpha=0; main_menu.scene="helloWorld" -- listener function local function onEveryFrame( event ) if (cnt~=0) then cnt= 3-(os.time()-start) minute = math.floor(cnt/60) second=cnt%60 --print(minute,second) minTxt=display.newText(minute,50,50,nil,100) secTxt=display.newText(second,250,50,nil,100) transition.to(minTxt, {time=100, alpha=0}) transition.to(secTxt,{time=100, alpha=0}) else Runtime: removeEventListener("enterFrame",onEveryFrame) countd_again.isVisible=true; main_menu.isVisible=true; transition.to(countd_again,{time=500,alpha=1}); transition.to(main_menu,{time=500,alpha=1}); countd_again: addEventListener("touch", changeScene) main_menu: addEventListener("touch", changeScene) end end -- assign the above function as an "enterFrame" listener Runtime:addEventListener( "enterFrame", onEveryFrame ) function changeScene(e) if(e.phase=="ended") then director:changeScene(e.target.scene); end end countd_again: addEventListener("touch", changeScene) main_menu: addEventListener("touch", changeScene) localGroup: insert(countd_again) localGroup:insert(main_menu) localGroup:insert(background) return localGroup; end

    Read the article

  • BIOS flash XP, 1 long beep, 2 short beeps, over&over

    - by Paul
    BIOS issue on HP dv9233cl laptop, wiped drive of Vista, loaded XP, not all the drives loaded. Went to the HP website, downloaded all drivers for this laptop. Started loading them. Loaded WIN Flash HP Network System BIOS Window SP42187. After a minute a low resolution screen appeared stating "It is now safe to turn off the computer" I waited a minute and half. Turned it off. Let it set 10 seconds try to start and No screen images at all and a nasty loud long beep 2 short beeps, 2 seconds of silence and it happens over & over again. I have unplugged/removed battery, still same problem, Any sugg.... Thx.. Paul

    Read the article

  • With Monit, how do I restart a process when a directory timestamp check fails?

    - by Alterscape
    In my /etc/monit/monitrc I have the following lines: check process foo_server with pidfile /var/run/bwam_server.pid start program = "/Users/foo/foo_server.sh start" stop program = "/Users/foo/foo_server.sh stop" check directory foo_data path "/Users/foo/Library/Application Support/foo_server/data" if timestamp > 1 minute then alert #if timestamp > 1 minute then restart foo_server I know I shouldn't have some of this stuff in my home directory, but this aside: if I uncomment the last line, Monit tells me syntax error on foo_server -- but I am, as far as I understand, correctly defining the process -- how else do I reference it?

    Read the article

  • iptables dos limit for all ports

    - by user973917
    I know how to use limit conntrack option to allow for DoS protection. However, I want to add a protection to limit no more than say 50 connections for each port. How can I do this? Basically, I want to make sure that each port can have no more than 50 connections, rather than globally applying 50 connections (which is what #2 does I believe?) Would I do something like: iptables -A INPUT --dport 1:65535 -m limit --limit 50/minute --limit-burst 50 -j ACCEPT or iptables -A INPUT -m limit --limit 50/minute --limit-burst 50 -j ACCEPT

    Read the article

  • Remotely from Chrome or IE page loads ~60seconds, from Firefox or IE on local machine - instantly.

    - by Janis Veinbergs
    The problem: If i access SharePoint from Windows 7 with IE8 or Chrome5 - I must wait for like a minute to get a response. If i use other Windows 7 with IE8, just the same - just wait a MINUTE. If i use Firefox3.6 on W7 machine - page opens up instantly. Now switch to IE rendering engine in Firefox, you will have to wait just as with IE. Now i tried IE8 on XP SP3 - page opens up instantly. I tried IE8 on Windows Server 2003 SP2 (machine on which SharePoint is hosted) - page opens up instantly. IIS6 Logs I did request almost instantly from all 3 browsers and this is what shows up in IIS logs (first 2 entries for each browser): Chrome Ok, IIS saw first Chrome request when i Hit enter in browser, but i had to wait long for things to move on 2010-06-01 05:46:04 W3SVC1794621940 192.168.0.9 GET /sapulces - 80 - 192.168.0.186 Mozilla/5.0+(Windows;+U;+Windows+NT+6.1;+en-US)+AppleWebKit/533.4+(KHTML,+like+Gecko)+Chrome/5.0.375.55+Safari/533.4 401 2 2148074254 Loading... 2010-06-01 05:47:07 W3SVC1794621940 192.168.0.9 GET /sapulces - 80 - 192.168.0.186 Mozilla/5.0+(Windows;+U;+Windows+NT+6.1;+en-US)+AppleWebKit/533.4+(KHTML,+like+Gecko)+Chrome/5.0.375.55+Safari/533.4 401 1 0 ... etc... Firefox All Instantly 2010-06-01 05:46:06 W3SVC1794621940 192.168.0.9 GET /sapulces - 80 - 192.168.0.186 Mozilla/5.0+(Windows;+U;+Windows+NT+6.1;+lv;+rv:1.9.2.3)+Gecko/20100401+Firefox/3.6.3 401 2 2148074254 2010-06-01 05:46:06 W3SVC1794621940 192.168.0.9 GET /sapulces - 80 - 192.168.0.186 Mozilla/5.0+(Windows;+U;+Windows+NT+6.1;+lv;+rv:1.9.2.3)+Gecko/20100401+Firefox/3.6.3 401 1 0 ... etc... IE I did hit enter when it was 05:46:06, but these are first entries in IIS logs 2010-06-01 05:47:08 W3SVC1794621940 192.168.0.9 GET /sapulces - 80 - 192.168.0.186 Mozilla/4.0+(compatible;+MSIE+7.0;+Windows+NT+6.1;+Trident/4.0;+SLCC2;+.NET+CLR+2.0.50727;+.NET+CLR+3.5.30729;+.NET+CLR+3.0.30729;+Media+Center+PC+6.0;+Tablet+PC+2.0;+.NET+CLR+1.1.4322;+.NET4.0C;+.NET4.0E) 401 1 0 2010-06-01 05:47:08 W3SVC1794621940 192.168.0.9 GET /sapulces - 80 - 192.168.0.186 Mozilla/4.0+(compatible;+MSIE+7.0;+Windows+NT+6.1;+Trident/4.0;+SLCC2;+.NET+CLR+2.0.50727;+.NET+CLR+3.5.30729;+.NET+CLR+3.0.30729;+Media+Center+PC+6.0;+Tablet+PC+2.0;+.NET+CLR+1.1.4322;+.NET4.0C;+.NET4.0E) 401 1 0 ... etc... Nothing to see in Event Logs. The question Similar question has been asked but there is no response and i`m trying to access page without SSL and that happens even on GET requests. Where do I look? Where would be the problem? Browser? OS? I don't even know what to think about. Just a note Just a note about chrome's process isolation: I found it sad that while I was waiting that minute with Chrome, i could not use any other tab (i could switch, but i could not, for example, scroll or use any controls)

    Read the article

  • DLINK WBR-1310B Wireless Router seems to hang...

    - by Ira Baxter
    I have a brand new DLINK-1310B Wireless Router (box never before opened, although I bought it at the neighborhood computer junk store). I am using it at home (and in fact am using it at this instant from a wireless laptop). When operative, I can ping it at 192.168.0.1, and I can log into it from the PC attached to it by LAN and from the wireless PC at //192.168.0.1. In the course of the day since I've installed, it seems to have locked up 3 times. Each time the symptoms are my web browser (or other IP service, e.g., POP3) stops with a "No internet connection" error. Attempts to contact the router via 192.168.0.1 get no reaction, from either the wireless laptop or from the hardwired PC sitting next to it. It doesn't respond to pings to that address either. Power cycling the router fixes it. I've seen discussion in other questions about aging cheap electronics. Its too new to be aged. Anybody else seen this behavior with a DLINK-1310? Or do I just need to exchange it for another and try again? (I hate rolling dice, I bought the DLINK because a previous Linksys died of apparant heating problems, how many do I have to cycle through before I get something that works and is long-term stable?). Remarkably, nobody talks about how much software is in a router. Is the stuff just buggy? EDIT: Happened again, while I was working on the wireless Vista laptop. (Seems like once an hour?) I was a little more careful this time. The wireless laptop can ping it. It can't get the login screen. I visited the LAN-connected PC (takes me a minute to walk from the laptop to the PC at the other end of the house), and attempted to visit a random web page. Surprise, that worked! And, now, after a minute walking back to the laptop, I can reconnect the wireless laptop, and get to the login page from it. Strange the time/date has been reset back to 2002. (I'll swear I set it and saved the system configuration after updating the firmware; it made me redo every other bit of reconfiguration again). Is there something funny about wireless leases expiring? The router says the leases it is handing out are good for 180 minutes, and the delay-to-inaccessible was only about an hour. The DSL connection seems to have a 10 minute lease.

    Read the article

  • Minutely cron, ensuring only a single instance

    - by Christopher Nadeau
    Is there a way to run a script every minute (or 2, or 5, etc), but only if it isn't already running? We have a set of scripts that need to run every minute. Sometimes they might start and finish in a second, other times they might go on for 5 minutes. Our current way of avoiding simultaneous executions is by setting a is_running flag in each script, and exiting if it's still enabled. But this is a little unreliable (i.e., fatal errors would cause the flag to remain enabled even after the script halted). We could write our own little manager, but I'm wondering if there is a more fashionable solution that already exists.

    Read the article

  • Monitoring ASA packet loss via SNMP

    - by dunxd
    I want to monitor packet loss on my ASA 5505 VPN endpoints using SNMP. This is so I can graph the rates in Cacti and/or get alerts in Nagios. However, I am not sure what SNMP values I should use to measure packet loss. In the ASA I can run sh interface Internet stats to show traffic statistics for the interface connected to the Internet. This shows 1 minute and 5 minute drop rates. Are these measures an indicator of packet loss? Are there SNMP values I can access that correspond to those values? Should I be looking at different values? Is the ASA even able to measure packet loss?

    Read the article

  • Powershell, Task Scheduler or loop and sleep

    - by Paddy Carroll
    I have a job that needs to go off every minute or so, it loads a DLL i have written in C# that retrieves state for an SQL Server Mirror (Primary, Mirror and witness) for a number of databases; it allows us to poke DNS to show where the primary instances are. Please don't mention Clustering - We're not doing that. I can't be arsed to write a service, there simply isn't enough time do I Task Scheduler - every minute: Invoke a powershell script that loads the DLL does the business Task scheduler - At Startup : Invoke a similer powershell script that loads the DLL once but then loops and sleeps, refreshing the Object that the DLL exposes. Pros and cons?

    Read the article

  • powershell task scheduler or loop and sleep

    - by Paddy Carroll
    I have a job that needs to go off every minute or so, it loads a DLL written in C# that retrieves state for an SQL Server Mirror (Primary, Mirror and witness) for a number of databases; it allows us to poke DNS to show where the primary instances are. Please don't mention Clustering - We're not doing that. I can't be arsed to write a service, there simply isn't enough time do I Task Scheduler - every minute: Invoke a powershell script that loads the DLL does the business Task scheduler - At Startup : Invoke a similer powershell script that loads the DLL once but then loops and sleeps, refreshing the Object that the DLL exposes. Pros and cons?

    Read the article

  • Can I configure mod_proxy to use different parameters based on HTTP Method?

    - by Graham Lea
    I'm using mod_proxy as a failover proxy with two balance members. While mod_proxy marks dead nodes as dead, it still routes one request per minute to each dead node and, if it's still dead, will either return 503 to the client (if maxattempts=0) or retry on another node (if it's 0). The backends are serving a REST web service. Currently I have set maxattempts=0 because I don't want to retry POSTs and DELETEs. This means that when one node is dead, each minute a random client will receive a 503. Unfortunately, most of our clients are interpreting codes like 503 as "everything is dead" rather than "that didnt work but please try that again". In order to program some kind of automatic retry for safe requests at the proxy layer, I'd like to configure mod_proxy to use maxattempts=1 for GET and HEAD requests and maxattempts=0 for all other HTTP Methods. Is this possible? (And how? :)

    Read the article

  • Why is the server performance so poor? What can be done to improve the speed of the server?

    - by fslsyed
    Very slow processing using Windows Server2008 R2 Standard with Service Pack One. Situation: Read a text file using the text data to populate a series of MS Sql tables. The converted data is used to generate monthly PDF invoice files; the PDF files are saved directly to the hard drive. The application is multi-threading with one thread used for the text conversion and three threads for PDF invoice generation. The text conversion is occurring concurrently with the invoice generation. Application Software: C# using Microsoft Visual Studio 2010 Ultimate. Crystal Report Writer 2011 with runtime 13_0_3 64 bit version. Targeted platform is x64; also tested as x86, and Any CPU with similar results. Microsoft .NET Framework 4.0. Microsoft Sql 2008 Issue: The software is running very slowly. The conversion of the text file is approximately six hundred fifty records per second and generation of the PDF files is approximately twelve invoices per minute. The text file to be converted is six hundred Meg with seven thousand invoices to be generated. The software was installed on three different machines from the same distribution files. The same text file was converted on each machine. The user executing the application was an administrator on each machine. The only variances were the machine and operating system. The configurations are as follows: Server: Operating System: Windows Server2008 R2 Standard 64-bit (6.1, Build7601) SP1 Service Pack: System Manufacturer: IBM System Model: System x3550 M3-[7944AC1]- BIOS: Default System BIOS Processor: Intel® Xeon® CPU E5620@ 2.4GHz (16 CPUs) Memory: 16384MB Notebook: Operating System: Windows 7 Home Premium Standard 64-bit (6.1, Build7601) System Manufacturer: Hewlett-Packard System Model: HP Pavilion dv7 Notebook PC BIOS: Default System BIOS Processor: AMD Phenom II N640 Dual-Core Processor 2.9GHz (2 CPUs) Memory: 6144MB Desktop: Operating System: Windows 7 Professional 64-bit (6.1, Build7601) SP1 System Manufacturer: Dell Inc. System Model: OptiPlex 960 BIOS: Phoenix ROM BIOS PLUS Version 1.10 A11 Processor: Intel Core™2 Quad CPU Q9650 @3.00GHZ (4 CPUs) Memory: 16384MB Processing results per machine: The applications were executed seven times with the averages being displayed below. Machine Text Records Invoices Generated Converted Per Minute Per Minute Server (1) 650 12 Notebook 980 17 Desktop 2,100 45 (1) The server is dedicated to execution of this application; no additional applications are being executed. Question: Why is the server performance so poor? What can be done to improve the speed of the server?

    Read the article

  • Hyperic HQ metrics not working

    - by Robin Weston
    I am having a problem with Hyperic HQ. Several metrics, some in IIS 6.x (Request Execution Time, Request Wait Time) and some in .NET 2.0 (Bytes in all Heaps, Exceptions Thrown per Minute), always show 0. If I view perfmon on the server itself I can see that the counters have values greater than zero. There are some metrics that work fine, such as Total Get Requests per Minute and the other IIS defaults. I have looked in the server logs but nothing obvious shows up. Please advise. Am happy to find more information if required.

    Read the article

  • excel 2010 search function?

    - by Tom
    can a cell A1:A200 be searched for a "name" then once found, imput the cell location into a formula? such as find "tom"(a1:a200), [found location at cell a22] IF(a22),=IF(MINUTE(Auto_Agent!G27)+(SECOND(Auto_Agent!G27))=0,"",(MINUTE(Auto_Agent!G27)*60+(SECOND(Auto_Agent!G27)))) the problem I'm having is each time I import data names can be in different cell locations depending on who is working that day. example: Agent: Tom 07:59:49 02:31:04 00:00:00 00:42:44 01:33:02 00:00:43 00:02:00 03:09:05 Avg Skillset Talk Time: 00:06:52 07:59:49 02:31:04 00:00:00 00:42:44 01:33:02 00:00:43 00:02:00 03:09:05 () 9/19/2012 Avg Skillset Talk Time: 00:06:52 07:59:49 02:31:04 00:00:00 00:42:44 01:33:02 00:00:43 00:02:00 03:09:05 Agent: Bill 07:59:49 02:31:04 00:00:00 00:42:44 01:33:02 00:00:43 00:02:00 03:09:05 Avg Skillset Talk Time: 00:06:52 07:59:49 02:31:04 00:00:00 00:42:44 01:33:02 00:00:43 00:02:00 03:09:05 () 9/19/2012 Avg Skillset Talk Time: 00:06:52 07:59:49 02:31:04 00:00:00 00:42:44 01:33:02 00:00:43 00:02:00 03:09:05

    Read the article

  • why is my Bamboo pen always drawing and a yellow note pad appears?

    - by cboi
    I have had a Bamboo pen and touch tablet for a couple years but have not used it in a long time. Now that I'm trying to use it again it is behaving very strangely. It won't drag anything on my desktop, the minute I try there is this yellow pad that appears and the pen draws a line on it instead of dragging the file. The yellow pad and drawn line disappear the second I lift the pen from the tablet. The most frustrating is it does the same thing when I try to draw in Photoshop. It won't draw with the paintbrush on my canvas because the minute I try to this yellow pad appears and it draws a line on it instead of on the canvas, which disappears the second I lift the pen from the tablet. It also bizarrely automatically switches from the paintbrush to the automatic selection tool. Has anyone had this problem? Any suggestions on how to fix this? I operate with Mac OS X 10.5.8

    Read the article

  • Which method of SQL Server 2005 or 2008 Replication is best for ease of field changes?

    - by Rick
    We need 15 minute warm updates from one SQL Server to another. Log Shipping looks good and appears easy to setup. We are also looking into Transactional Replication. The data only needs to copy one way. We have two main requirements: 1) The destination database needs to be a max 15 minute old copy of the source. It needs to re-try and get up-to-date if a network cable is unplugged for a while. 2) We would really like table (fields added or modified) changes in the source as easy as possible. Thanks in advance for all suggestions.

    Read the article

  • High load on a nagios server -- How many service checks for a nagios server is too many?

    - by Josh
    I have a nagios server running Ubuntu with a 2.0 GHz Intel Processor, a RAID10 array, and 400 MB of RAM. It monitors a total of 42 services across 8 hosts, most of which are checked using the check_http plugin even 5 minutes, some every minute. Recently the load on the nagios server has been above 4, often as high as 6. The server also runs cacti, gathering statistics every minute for 6 hosts. I wonder, how many services should hardware like this be able to handle? Is the load so high because I am pushing the limits of the hardware, or should this hardware be able to handle 42 service checks plus cacti? If the hardware is inadequate, should I look to add more RAM, more cores, or faster cores? What hardware / service checks are others running?

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >